Sie sind auf Seite 1von 6

INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 1/6

STATION INFORMATION

Station code: MAESTRIA

Model: SARA GEOBOX

Sensor: SARA SS45PACK (integrated 4.5 Hz sensors)

Notes: -

PLACE INFORMATION

Place ID: BARRIO BOLAÑOS

Address: VIA ANTIGUA A CUMBAYA

Latitude: 781615

Longitude: 9978628

Coordinate system: UTM

Elevation: 0 MASL

Weather: NO

Notes: -

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it


INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 2/6

PHOTOGRAPHIC REFERENCES

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it


INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 3/6

SIGNAL AND WINDOWING

Sampling frequency: 300 Hz

Recording start time: 2018/07/08 13:36:38

Recording length: 10 min

Windows count: 16

Average windows length: 20

Signal coverage: 53.33%

3497 Counts CHANNEL #1 [V]

-4472 Counts

5754 Counts CHANNEL #2 [N]

-5887 Counts

5598 Counts CHANNEL #3 [E]

-7573 Counts

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it


INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 4/6

HVSR ANALYSIS

Tapering: Enabled (Bandwidth = 5%)


Smoothing: Konno-Ohmachi (Bandwidth coefficient = 40)
Instrumental correction: Disabled

HVSR average

Signal spectra average

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it


INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 5/6

HVSR time-frequency analysis (5 seconds windows)

HVSR directional analysis

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it


INVESTIGACIÓN GEOLÓGICO - GEOTÉCNICA Page 6/6

SESAME CRITERIA

Selected f0 frequency
0.874 Hz

A0 amplitude = 2.780
Average f0 = 0.764 ± 0.122

SARA electronic instruments srl - GeoExplorer HVSR 2.2.3 www.sara.pg.it

Das könnte Ihnen auch gefallen