Sie sind auf Seite 1von 8

Experiment 8: Minor Losses

 Purpose:

To determine the loss factors for flow through a range of pipe fittings
including bends, a contraction, an enlargement and a gate-valve.

 Introduction:

Energy losses in pipe flows are the result of friction between the fluid and the
pipe walls and internal friction between fluid particles. Minor (secondary) head
losses occur at any location in a pipe system where streamlines are not straight, such
as at pipe junctions, bends, valves, contractions, expansions, and reservoir inlets and
outlets. In this experiment, minor head losses through a pipe section that has several
bends, transitions, and fittings will be measured.

 Apparatus:

Energy Losses in Bends and Fittings Apparatus.

It consists of:

- Sudden Enlargement

- Sudden Contraction

- Long Bend

- Short Bend

- Elbow Bend

- Mitre Bend figure 1:minor losses apparatus

Figure 2: Schematic drawing of the energy-loss apparatus


Figure 3: Minor Losses Apparatus with hydraulic bench

- Flow rate through the circuit is controlled by a flow control valve.


- Pressure tappings in the circuit are connected to a twelve bank manometer, which
incorporates an air inlet/outlet valve in the top manifold. An air bleed screw
facilitates connection to a hand pump. This enables the levels in the manometer
bank to be adjusted to a convenient level to suit the system static pressure.
- A clamp which closes off the tappings to the mitre bend is introduced when
experiments on the valve fitting are required. A differential pressure gauge gives a
direct reading of losses through the gate valve.

 Theory:

The energy balance between two points in a pipe can be described by the
Bernoulli equation, given by
p1 V2 p V2
 z1  1  2  z 2  2  hL
 2g  2g
where pi is static pressure (in Pa) at point i, g is specific weight of the fluid (in
N/m3), zi is the elevation (in meters) of point i, Vi is the fluid velocity (in m/s) at
point i, g is the gravitational constant (in m/s2), and hL is head loss (in meters).

The term pi/ is referred to as the static head; zi is the elevation head; and Vi2/2g is the
dynamic (or velocity) head. The summation of the static head and the elevation head, pi/ +
zi, is referred to as the piezometric head. The piezometric head is what is measured with the
piezometer (manometer) board on the apparatus for this experiment.

Head loss, hL, includes the sum of pipe friction losses, hf, and all minor losses,
hL  h f  h
i 1n
i

where hi is the minor head loss (in meters) for the ith component and n is the number
of components (fittings, bends, etc.).
Pipe friction losses are expressed as the Darcy-Weisbach equation given by
L V2
hf  f
D 2g
where f is a friction factor, L is the pipe length, and D is the pipe diameter. Pipe
friction losses are assumed to be negligible in this experiment

The energy loss which occurs in a pipe fitting (so-called secondary loss) is
commonly expressed in terms of a head loss (h, meters) in the form:
V2
h  K
2g
Where K = the loss coefficient and

v = mean velocity of flow into the fitting, For the expansion and contraction,
the V used is the velocity of the fluid in the smaller-diameter pipe.

Because of the complexity of flow in many fittings, K is usually determined


by experiment. For the pipe fitting experiment, the head loss is calculated from two
manometer readings, taken before and after each fitting, and K is then determined as
V 2 
K  h /  
 2g 
Due to the change in pipe cross-sectional area through the enlargement and
contraction, the system experiences an additional change in static pressure. This
change can be calculated as
2 2
v1 / 2 g  v2 / 2 g

To eliminate the effect of this area change on the measured head losses, this
value should be added to the head loss readings for the enlargement and the
2 2
contraction. Note that (h1 - h2) will be negative for the enlargement and v1 / 2 g  v2 / 2 g
will be negative for the contraction.

For the gate valve experiment, pressure difference before and after gate is measured
directly using a pressure gauge. This can then be converted to an equivalent head loss
using the equation

1 bar = 10.2 m water

 Procedure:

It is not possible to make measurements on all fittings simultaneously and,


therefore, it is necessary to run two separate tests.

o Part A:

1) Set up the losses apparatus on the hydraulic bench so that its base is horizontal
by adjusting the feet on the base plate if necessary. (this is necessary for accurate
height measurements from the manometers). Connect the test rig inlet to the bench
flow supply and run the outlet extension tube to the volumetric tank and secure it
in place.

2) Fully open the gate valve and the outlet flow control valve at the right hand end of the
apparatus.

3) Close the bench flow control valve then start the service pump.

4) Gradually open the bench flow control valve and allow the pipework to fill with
water until all air has been expelled from the pipework.

5) In order to bleed air from pressure tapping points and the manometers close
both the bench valve and the test rig flow control valve and open the air bleed
screw and remove the cap from the adjacent air valve. Connect a length of small
bore tubing from the air valve to the volumetric tank. Now, open the bench valve
and allow flow through the manometers to purge all air from them; then, tighten
the air bleed screw and partly open both the bench valve and the test rig flow
control valve.

Next, open the air bleed screw slightly to allow air to enter the top of the
manometers, re-tighten the screw when the manometer levels reach a convenient
height.

6) Check that all manometer levels are on scale at the maximum volume flow rate
required (approximately 17 liters/ minute). These levels can be adjusted further by
using the air bleed screw and the hand pump supplies. The air bleed screw
controls the air flow through the air valve, so when using the hand pump, the
bleed screw must be open. To retain the hand pump pressure in the system, the
screw must be closed after pumping.

7) If the levels in the manometer are too high then the hand pump can be used to
pressurise the top manifold. All levels will decrease simultaneously but retain the
appropriate differentials.

If the levels are too low then the hand pump should be disconnected and the
air bleed screw opened briefly to reduce the pressure in the top manifold.
Alternatively the outlet flow control valve can be closed to raise the static pressure
in the system which will raise all levels simultaneously.

If the level in any manometer tube is allowed to drop too low then air will
enter the bottom manifold. If the level in any manometer tube is too high then
water will enter the top manifold and flow into adjacent tubes.

8) Adjust the flow from the bench control valve and, at a given flow rate, take
height readings from all of the manometers after the levels have steadied. In order
to determine the volume flow rate, you should carry out a timed volume collection
using the volumetric tank. This is achieved by closing the ball valve and
measuring (with a stopwatch) time taken to accumulate a known volume of fluid
in the tank, which is read from the sight glass. You should collect fluid for at least
one minute to minimize timing errors. ( note: valve should be kept fully open.)

9) Repeat this procedure to give a total of at least five sets of measurements over a
flow range from approximately 8 - 17 liters per minute.

o Part B:

10) Clamp off the connecting tubes to the mitre bend pressure tappings (to prevent
air being drawn into the system).

11) Start with the gate valve closed and open fully both the bench valve and the
lest rig flow control valve.

12) open the gate valve by approximately 50% of one turn (after taking up any
backlash).

13) For each of at least 5 flow rates, measure pressure drop across the valve from
the pressure gauge; adjust the flow rate by use of the test rig flow control valve.
Once measurements have started, do not adjust the gale valve. Determine the
volume flow rate by timed collection.

14) Repeat this procedure for the gate valve opened by approximately 70% of one
turn and then approximately 80% of one turn.

 Data & Results:

The following dimensions from the equipment are used in the appropriate
calculations.

Internal diameter of pipework d = 0.0183 m

Internal diameter of pipework at enlargement outlet and contraction inlet

d = 0.0240 m
Table 1. Raw Data for All Fittings Except Gate Valve
Case No. I II III IV V
Volume (L)
Time (sec)
1
Enlargement
2
Piezometer Readings (mm)

3
Contraction
4
5
Long Bend
6
7
Short Bend
8
9
Elbow
10
11
Mitre Bend
12

Table 2. Raw Data for Gate Valve


Case No. I II III IV V
Volume (L)
50% Opened

Time (sec)
Gauge Red
Reading (upstream)
(bar) Black
(downstream)
Volume (L)
70% Opened

Time (sec)
Gauge Red
Reading (upstream)
(bar) Black
(downstream)
Volume (L)
80% Opened

Time (sec)
Gauge Red
Reading (upstream)
(bar) Black
(downstream)
Table 3. Minor Head Losses of All Fittings Except Gate Valve
Case No. I II III IV V
Q (m3/sec)
V (m/s)
V2/2g (m)
Enlargement
Minor Head Losses

Δh
2 2
Δh +V1 /2g- V2 /2g
Contraction Δh
(m)

2 2
Δh +V1 /2g- V2 /2g
Long Bend
Short Bend
Elbow
Mitre Bend

Table 4. Loss Coefficients for All Fittings Except Gate Valve


Case No. I II III IV V
Q (m3/sec)
V (m/s)
V2/2g (m)
Enlargement
Coefficients

Contraction
Long Bend
Loss

Short Bend
Elbow
Mitre Bend

Table 5. Equivalent Minor Head Loss and Loss Coefficient for Gate Valve
Case No. I II III IV V
Q (m3/sec)
50% Opened

V (m/sec)
V2/2g (m)
Minor Head
Loss (m)
Loss Coefficient
Q (m3/sec)
70% Opened

V (m/sec)
V2/2g (m)
Minor Head
Loss (m)
Loss Coefficient
Q (m3/sec)
80% Opened

V (m/sec)
V2/2g (m)
Minor Head
Loss (m)
Loss Coefficient
Calculations and Results

Fill in Tables 3 – 5 with calculated results. Assume that the pipe friction
losses between the upstream and downstream manometer ports are negligible, so the
total head loss is due to minor head losses. Remember the piezometric head is what is
measured with the piezometer (manometer) board on the experimental apparatus.

Questions

1. For Exercise A, prepare plots that show the effect of dynamic head on minor head
loss (i.e. plot graphs of head loss (∆h) against dynamic head ( )), and the effect of flow
rate on loss coefficients (i.e. K against volume flow rate Q).
2. For Exercise B, prepare plots that show the effect of dynamic head on equivalent
head loss (i.e. (∆h) against ( )), and the effect of flow rate on loss coefficients (i.e. K
against volume flow rate Q).
3. Comment on and explain the relationships evident in the plots of Questions 1 and
2. Include a comparison of the loss coefficients and geometry for the four types of
bends.
a. Is it justifiable to treat the loss coefficient as constant for a given
fitting? Explain.
b. How does the loss coefficient for the gate valve vary with the extent of
the opening of the valve? Explain.
4. Compare the experimental loss-coefficient values for different fittings to those
found in a fluid mechanics text book (or another source). Be sure to site the
source of the published values.
5. Does the static pressure increase or decrease for the enlargement and contraction?
Explain the increase or decrease in static pressure.

Das könnte Ihnen auch gefallen