Sie sind auf Seite 1von 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Drilled Cast-in-place Pile Design Based on ACI 318-05

DESIGN CRITERIA
1. SEND TO GEOTECHNICAL ENGINEER THE BASE FORCES OF COLUMNS AND THE PERMISSIBLE DEFLECTION AT TOP PILE.
(PERMISSIBLE DEFLECTION 0.25 in SUGGESTED)
2. ASSUME FIX HEAD CONDITION IF Ldh & Lhk COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.
3. FROM SOIL REPORT, DETERMINE PILE PATTERN, LENGTH, AND MAX SECTION FORCES OF SINGLE PILE, P u, Mu, & Vu.
4. PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH S DS/10 TIMES AXIAL CAPACITY OF VERT COLUMN LOADING.
(IBC 1808.2.23.1)

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc ' = 5 ksi
VERT. REBAR YIELD STRESS fy = 60 ksi
PILE DIAMETER D = 20 in
PILE LENGTH L = 35 ft
FACTORED AXIAL LOAD Pu = 480 k
FACTORED MOMENT LOAD Mu = 200 ft-k
FACTORED SHEAR LOAD Vu = 20 k
PILE VERT. REINF. 8 # 7
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties
LATERAL REINFORCEMENT # 4 @ 6 in o.c.
( 3.0 in o.c. at each end.)

( L dh = 8 in & L hk = 14 in )

THE PILE DESIGN IS ADEQUATE.

ANALYSIS

CHECK PILE LIMITATIONS


fc ' = 5 ksi > 2.5 ksi [Satisfactory] (IBC 1810.1.1)
D= 20 in > MAX( L / 30 , 12 in) [Satisfactory] (IBC 1810.3.2)

CHECK FLEXURAL & AXIAL CAPACITY

(
2 0.85 f '
C )
o = , E c = 57 , E s = 29000ksi
'
f C
Ec

ì é æ  ö æ  ö2ù
ï
ï0.85 f
'
ê2 ç c ÷ - ç c ÷ ú , for 0 <  c <  o
=í êë è  o ø è  o ø úû
C
f C
ï
ï
î0.85 f
'
, for  c ³  o

C

ï s E s , for  s £  y
ì
f =í
S
ï f , for  s >  y
î y
(cont'd)
1200

1000 f Pn (kips) f Mn (ft-kips)


AT COMPRESSION ONLY 954 0
800
AT MAXIMUM LOAD 954 75
600 AT 0 % TENSION 693 173
f Pn (k) AT 25 % TENSION 565 196
400 AT 50 % TENSION 458 204
AT  t = 0.002 298 201
200
AT BALANCED CONDITION 270 188
0 AT  t = 0.005 75 186
0 50 100 150 200 250
AT FLEXURE ONLY 0 143
-200
AT TENSION ONLY -259 0
-400

f Mn (ft-k)

f Pmax =0.85 f [ 0.85 fc' (Ag - Ast) + fy Ast] = 953.7 kips., (at max axial load, ACI 318-05, Sec. 10.3.6.1)
where f = 0.70 (ACI 318-05, Sec.9.3.2.2) > Pu [Satisfactory]
2
Ag = 314 in . Ast = 4.80 in2.

a = Cbb 1 = 8 in (at balanced strain condition, ACI 10.3.2)


0.7 + ( t - 0.002 ) (200 / 3), for Spiral
f= = 0.656 (ACI 318-05, Fig. R9.3.2)
0.65 + ( t - 0.002 ) (250 / 3), for Ties

where   
Cb = d c / ( c + s) = 10 in t = 0.002069 c = 0.003
d = 16.1 in, (ACI 7.7.1) b1 = 0.8 ( ACI 318-05, Sec. 10.2.7.3 )

f Mn = 0.9 Mn = 143 ft-kips @ Pn = 0, (ACI 318-05, Sec. 9.3.2) ,& t,max = 0.004, (ACI 318-05, Sec. 10.3.5)
f Mn = 202 ft-kips @ Pu = 480 kips > Mu [Satisfactory]
rmax = 0.08 (ACI 318-05, Section 10.9) rprovd = 0.015
rmin = 0.005 (IBC, Section 1810.1.2.2) [Satisfactory]

CHECK SHEAR CAPACITY


f Vn = f (Vs + Vc) = 70 kips, (ACI 318-05 Sec. 11.1.1)
> Vu [Satisfactory]
where f = 0.75 (ACI 318-05 Sec. 9.3.2.3)
2 2
A0 = 203 in . Av = 0.40 in . fy = 60 ksi
Vc = 2 (fc')0.5A0 = 28.7 kips, (ACI 318-05 Sec. 11.3.1)
Vs = MIN (d fy Av / s , 4Vc) = 64.3 kips, (ACI 318-05 Sec. 11.5.7.2 & 11.5.7.9)
smax = 6 (IBC 06 , Section 1810.1.2.2) sprovd = 6 in
smin = 1 [Satisfactory]

DETERMINE FIX HEAD CONDITION

æ r ö
requird 0.02y el d b f
L dh = MAX çh , 8d b , 6 in ÷ =
y
10 db = 8 in
ç r provided '
fc ÷
è ø (ACI 318-05 12.5.2)

L hk = 14 in, (ACI 318-05, Fig. R12.5)

where db = 0.88 in
r required / r provided = 0.8 ( A s,reqd / A s,provd , ACI 318, 12.2.5)
ye = 1.0 (1.2 for epoxy-coated, ACI 318-05 12.2.4)
l = 1.0 (normal weight)
h = 0.7 (#11 or smaller, cover > 2.5" & side >2.0",
ACI 318-05 12.5.3)

Das könnte Ihnen auch gefallen