CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Drilled Cast-in-place Pile Design Based on ACI 318-05
DESIGN CRITERIA
1. SEND TO GEOTECHNICAL ENGINEER THE BASE FORCES OF COLUMNS AND THE PERMISSIBLE DEFLECTION AT TOP PILE.
(PERMISSIBLE DEFLECTION 0.25 in SUGGESTED)
2. ASSUME FIX HEAD CONDITION IF Ldh & Lhk COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.
3. FROM SOIL REPORT, DETERMINE PILE PATTERN, LENGTH, AND MAX SECTION FORCES OF SINGLE PILE, P u, Mu, & Vu.
4. PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH S DS/10 TIMES AXIAL CAPACITY OF VERT COLUMN LOADING.
(IBC 1808.2.23.1)
( L dh = 8 in & L hk = 14 in )
ANALYSIS
(
2 0.85 f '
C )
o = , E c = 57 , E s = 29000ksi
'
f C
Ec
ì é æ ö æ ö2ù
ï
ï0.85 f
'
ê2 ç c ÷ - ç c ÷ ú , for 0 < c < o
=í êë è o ø è o ø úû
C
f C
ï
ï
î0.85 f
'
, for c ³ o
C
ï s E s , for s £ y
ì
f =í
S
ï f , for s > y
î y
(cont'd)
1200
f Mn (ft-k)
f Pmax =0.85 f [ 0.85 fc' (Ag - Ast) + fy Ast] = 953.7 kips., (at max axial load, ACI 318-05, Sec. 10.3.6.1)
where f = 0.70 (ACI 318-05, Sec.9.3.2.2) > Pu [Satisfactory]
2
Ag = 314 in . Ast = 4.80 in2.
where
Cb = d c / ( c + s) = 10 in t = 0.002069 c = 0.003
d = 16.1 in, (ACI 7.7.1) b1 = 0.8 ( ACI 318-05, Sec. 10.2.7.3 )
f Mn = 0.9 Mn = 143 ft-kips @ Pn = 0, (ACI 318-05, Sec. 9.3.2) ,& t,max = 0.004, (ACI 318-05, Sec. 10.3.5)
f Mn = 202 ft-kips @ Pu = 480 kips > Mu [Satisfactory]
rmax = 0.08 (ACI 318-05, Section 10.9) rprovd = 0.015
rmin = 0.005 (IBC, Section 1810.1.2.2) [Satisfactory]
æ r ö
requird 0.02y el d b f
L dh = MAX çh , 8d b , 6 in ÷ =
y
10 db = 8 in
ç r provided '
fc ÷
è ø (ACI 318-05 12.5.2)
where db = 0.88 in
r required / r provided = 0.8 ( A s,reqd / A s,provd , ACI 318, 12.2.5)
ye = 1.0 (1.2 for epoxy-coated, ACI 318-05 12.2.4)
l = 1.0 (normal weight)
h = 0.7 (#11 or smaller, cover > 2.5" & side >2.0",
ACI 318-05 12.5.3)