4
Technical basics
System description ............................................................................................................................... 04-0-10-01
Construction, applications, advantages, function
System design ..................................................................................................................................... 04-0-10-02
Design and installation of progressive systems
Calculation of the main distributor ......................................................................................................... 04-0-10-03
Lines
Table of contents
Installation of the distributor
Selection criteria .................................................................................................................................. 04-0-10-04
Calculation of the pump operation time
Functional description of distributors in disk construction ...................................................................... 04-0-10-05
Functional description of distributors in segment construction .............................................................. 04-0-10-06
Functional description of distributors in sandwich construction ............................................................. 04-0-10-07
Table of contents
Progressive distributor SX-2 / SX-3
Technical description / technical data .................................................................................................... 04-1-30-01
Elements ............................................................................................................................................... 04-1-30-02
·Initial element
·Middle element
·End element
Combination of outlets .......................................................................................................................... 04-1-30-03
·Combination of outlets at one middle elementSX-2 / SX-3
·Combination von outlets an some middle elements ............................................................................ 04-1-30-04
·Distributor bridge with outlet
·Distributor bridge without outlet .................................................................................................. 04-1-30-05
Elements with proximity switch/ technical data ...................................................................................... 04-1-30-06
Visual stroke control (only for SX-2) ...................................................................................................... 04-1-30-07
Extension or shortening of distributors .................................................................................................. 04-1-30-08
Pressure indication (only for SX-2) ....................................................................................................... 04-1-30-09
Order key ............................................................................................................................................. 04-1-30-10
Progressive distributor UX
Technical description / Technical data ................................................................................................... 04-1-40-01
04-0-00-03
·End element
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Table of contents
4
Metering elements
Combination of outlets .......................................................................................................................... 04-2-15-05
· Combination of outlets at one basic element
· Combination of outlets at several basic elements................................................................................ 04-2-15-06
· Distributor bridge without outlet
Elements with proximity switch / technical data ..................................................................................... 04-2-15-07
Elements with indicator pin .................................................................................................................... 04-2-15-08
04-0-00-04
Table of contents
·End element
Metering elements ............................................................................................................................... 04-2-20-04
Dummy elements ................................................................................................................................. 04-2-20-05
Combination of outlets .......................................................................................................................... 04-2-20-07
·Combination of outlets at one distributor disk
·Combination of outlets at several distributor disks ........................................................................... 04-2-20-08
· SXE-3 distributor bridge with outlet
· Distributor bridge without outlet ...................................................................................................... 04-2-20-09
Elements with proximity switch / technical data ..................................................................................... 04-2-20-10
Elements with indicator pin ................................................................................................................... 04-2-20-11
Exchange of a metering element .......................................................................................................... 04-2-20-12
Extension or shortening of distributors
Order key ............................................................................................................................................. 04-2-20-13
1090200390
Technical basics
NLGI-cl. 2. leconomic supply of many lubrication points by one
single pump
The progressive system works with pressures of 10 lsimple electronic monitoring of the lubricant
to 300 bar, depending on the back pressure or the volume
line- and distributor resistance.
Function
Construction Progressive systems distribute the lubricant
A progressive system mainly consists of a central progressively via a follower piston control.
lubrication pump, the progressive distributors and a
control unit. Because of this follower piston control a progressive
system can easily be monitored with a pressure
limitation valve. If one of the lubrication points is not
lubricated, the follower piston control is stopped. The
system blocks and the lubricant comes out of the
pressure limitation valve.
Central lubrication
pump
state: 09.14EN
Applications
The main application fields of progressive systems
are presses and synthetic processing machines,
printing- and paper processing machines, machine
04-0-10-01
The choice of the lubrication metering components with an electrically driven pump and integrated
depends on the size and the number of the bearing control.
points which have to be lubricated.
500 300*
Central lubrication pump 150 500*
150* 220*
Main
distributor 1
45*
75
SXE-2 distributor 25
25
400* 45 45*
150 75* 25
620* Secondary distributor 1 75
105 25
25 25
25 45
45 75
25 75 25
45 45
75* 45* Secondary
distributor 2 105
75 45*
105
state: 09.14EN
MX-F distributor
25 75 45
45 45 75*
25 25 25
75 75 105
25 25 75
45* 105 45
25 45 25
04-0-10-02
Secondary distributor 3
Subject to alterations! © BEKA 2014 All rights reserved!
BAIER + KÖPPEL
BEKA Nederland GmbH + CO KG Wagenmakerij
B.V. BEETHOVENSTR.11 14 POSTFACH tel.1320 TEL.: +49 9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK 4762 D-91257 PEGNITZ
AV Zevenbergen D-91253 PEGNITZ FAX: +49 9241 729-50
fax. 0168 338 329 E-MAIL: beka@beka-lube.de
www.beka.nl
Progressive Central Lubrication Systems
Technical basics
Technical basics
other. bearing back-pressures have to be expected
.
They are also necessary for the outlets of those main
See figure on the previous page:
distributors which supply the secondary distributors.
Secondary distributor 1:
(25 + 45 + 75) x 2 = 290
Installation of the distributor
Secondary distributor 2: Caution:
(105+25+25+45+75) x 2 = 550 Please always install the progressive
distributors with the pistons in horizontal
Secondary distributor 3: position.
(25 + 45 + 25 + 75 + 25 + 45 + 25 + 75 + 25 + 45 +
75) x 2 = 970
Secondary distributor 4:
(75 + 45 + 25 + 75 + 25 + 105 + 45 + 25 + 75) x 2 25
= 990 45
45
105
45
The metering volume code numbers have to be
45
multiplied with 2 as the distributor disks deliver on the
75*
left and on the right.
75
RIGHT
75*
25
45
45
45
45
75
The relations does not have to correspond exactly. A The surface has to be even and free of anything that
tolerance of ± 0,2 is permissible. could possibly lead to tensions.
04-0-10-03
1090200390
Secondary distributor 1:
25 + 45 + 75 = 145 x 2 = 290 mm³
Secondary distributor 2:
105 + 25 + 25 + 45 + 75 = 275 x 2 = 550 mm³
Secondary distributor 3:
25 + 45 + 25 + 75 + 25 + 45 + 25 + 75 + 25 + 45 +
75 = 485 x 2 = 970 mm³
Secondary distributor 4:
75 + 45 + 25 + 75 + 25 + 105 + 45 + 25 + 75 = 495
x 2 = 990 mm³
1090200390
Technical basics
The progressive distributors consist of distributor
disks, which are combined to distributor blocks by
2 5
connecting rods (hexagon socket screws) and disks.
O-rings seal the individual elements. I
4 1
According to the functional description, the following
distributors operate: MX-F, LX-4, SX-1, SX-2, SX-3,
UX.
Figure C
III
III
3 6
II
3 6
II
2 5
I
2 5
I 4 1
4 1
Pressure
state: 09.14EN
chamber After the piston III has been moved, the lubricant is
directed to the piston’s right side again (fig.A) and a
After that, the lubricant is delivered to the outlets 2 new cycle of the progressive piston distributor is
and 3 by the progressive movement of the pistons (II effected. This function is repeated as long as
and III). Then the lubricant is directed to the left side lubricant is supplied to the progressive distributor.
of the piston (I) (fig. C) and delivered out of the
piston’s right pressure chamber to outlet 4.
04-0-10-05
= pressure ducts
= already supplied
= following metering stroke
1090200390
1 4
III
1 4
III
2 5
I
= pressure ducts
= already supplied
1 4
1090200390
Technical basics
means of internal hexagon screws. The occuring
6 3
distributor disks are combined by means of washers II
and nuts. The sealing of the individual elements is
done by O-rings. 5 2
I
The following figures A to D show an output rate of a
simple metering volume. 1 4
Figure C
III
Return (R)
6 3
II
5 2
I III
1 4 6 3
II
1 4
piston (I) (Fig. A). The piston (I) is moved to the right
and lubricant is pressed out of the right pressure After piston (III) is moved, lubricant is supplied to the
chamber of the piston to outlet 1. right side of the piston (I) (Fig. C) and supplied to
outlet 4 of the left pressure chamber of the piston.
04-0-10-07
1090200390
Figure D Return
III III
Technical basics
6 3 6 3
II II
5 2 5 2
I I
1 4 1 4
X
Pressure chamber Inlet (P) Pressure chamber Inlet (P)
Afterwards the metering pistons (II) and (III) are The outlets can be closed with sealing screws
moved in sequence (Fig. D) and lubricant is without blocking the distributor as the provided
delivered to outlets 5 and 6 one after another. metering volume is supplied to the return (see outlet
5).
After piston (III) is moved, the progressive distributor
starts a new cycle. This described function is
X
repeated as long as lubricant is supplied to the
Outlet sealed with sealing screw,
progressive distributor. metering volume flows to return.
5
Outlet in function
Metering lubricant flows through
the outlet fitting
(= seperated from return) 1
state: 09.14EN
= pressure ducts
= already supplied
= following metering stroke
04-0-10-08
1090200390
Technical basics
220 XXX 220
BEKA 630 SXW-1 II
300 XXX 300 5 2
BEKA 400 SXW-1
630 XXX 630 I
4 1
BEKA 220 SXW-1
400 XXX 400
Metering
code
number Inlet
Figure C
Then the way to piston III gets free and lubricant out
The progressive distributors SXW-1 and SXW-2 in
of the right pressure chamber is directed to outlet 2.
sandwich construction, consists of a connecting
plate and several metering elements. The metering
elements are connected with the connecting plate by
means of hexagon socket screws. The individual
elements are sealed by O-rings. III
6 3
Figure A II
5 2
The supplied lubricant flows through the connecting
through the ring groove of piston III to the left side of I
piston I and shifts it to the right side. The lubricant of 4 1
the right pressure chamber of piston I flows to outlet
6.
Figure D
III After piston III has been moved, the lubricant is led to
6 3 the piston’s right side and shifts it to the left. The
lubricant of the left pressure chamber of the piston I
II
5 2 is supplied to outlet 3.
state: 09.14EN
I
4 1
III
6 3
II
5 2
I
04-0-10-09
4 1
1090200390
Figure E
The way to piston II is free and the lubricant of the left
pressure chamber is directed to outlet 4.
III
Technical basics
6 3
II
5 2
I
4 1
Figure F
Then the way to piston III is free and the lubricant of
the left pressure chamber is led to outlet 5.
III
6 3
II
5 2
I
4 1
= pressure ducts
= current metering stroke
04-0-10-10
1090200390
Disk construction
Progressive distributors
SX-1 SX-2 SX-3 SX-5
r)
ts
le . o (ba
ax ss in
le
r o ok e
re m
ut
pe /str lum
. n ure
fo
.p s/
n
co ets n
ut e
tio
m vo
n
t)
ut io
tio
m tio
s
le
na
O ect
o
m
(m ge
re
ec
ia
lu
iu
ig
er
u
a
nn
nn
³
re .
pe
vo
at
ax
ax
ed
os
es
at
co
Fe
Ty
In
M
D
D
- use in mobile range (on- u.
off-road vehicles, agricultural and
MX-F 4010 180 300 24 M10x1 M10x1 galv. 25 - 105 construction machinery, etc.)
steel - special coating for hardest
operating conditions available
- especially suitable for food
MX-I 3979 60 300 16 M10x1 M10x1 1.4404 45 - 105 industry and aggressive
environment
- highest material quality (1.4404)
- perfect for applications, for which
VA is not absolutely necessary,
LX-2 3972 180 300 20 M10x1 M10x1 steel, 200 however high corrosion protection
ZnNi - 100 % compatible dimensions
and output rate to similar
block distributors
- construction identic to LX-2
- perfectly suitable for beverage and
LX-3 3973 60 300 20 M10x1 M10x1 1.4404 200 oils packing industry
1.4401 and - 100 % compatible dimensions
greases and output rate to similar
up to block distributors
NLGI- - LX-2 alternative but high
cl. 2 metering flexibility
LX-4 3950 180 300 20 M10x1 M10x1 steel, 50 - 200 - clearly less space necessary
ZnNi due to various
dosage possibilties
- due to up-positioned sealing
SX-1 4000 180 300 20 G 1/8 G 1/8 galv. 68 - 430 washers, easy outlet combination
steel without loosening of pipe lines
state: 09.14EN
and fittings
- see SX-1
SX-2 3989 180 300 20 G 1/8 G 1/8 galv. 75 - 470 - compact construction but high
steel volume flow
- alternative to SX-2, but with
V2A (1.4301)
SX-3 4008 60 300 20 G 1/8 G 1/8 1.4301 75 - 470 - especially suitable for food
04-1-00-01
steel area
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Progressive distributor
Overview
ou )
of bar
ts
ax ss in
tle
(
r o ok e
re m
pe /str lum
e
ur
.p s/
n
ut e
io
m vo
n
t)
ut tio
tio
at
m tio
s
le
.
In no
m
(m ge
re
O ec
ec
ia
co ts
n
lu
iu
ig
er
u
e
a
nn
nn
³
re .
.
pe
vo
at
ax
ax
ed
os
es
le
at
co
Fe
Ty
M
D
D
- outlets positioned upwards;
UX 4005 180 250 20 G 1/2 G 3/8 galv. 1130 - 2000 easily detachable when swivel
steel joints are used at the pipe lines
Progressive distributors
extended or shortened. Because of the disk
construction there is the possibility to join individual Metering code no.
End element
distributor disks (middle element, end element) with
Middle element
different metering volumes together to one complete 45
progressive distributor. 75
25
The different metering volume per stroke is effected 45
by different piston diameters.
Inlet
Technical data Initial element
Operating pressure inlet: max. 300 bar
Temperature range: -30 °C to 80 °C
Metering medium: oil - fluid grease - grease Dimensional drawing
up to NLGI-cl. 2 “A” 50
Revolutions: max. 180 r/min 22,4 14,75
5
23,5
No. of elements:
min. 3 piston elements: MX-F 3/6
M10x1
11,5
M10x1 outlets
max. 12 piston elements: MX-F 12/24
Ø 10 inlet
Ø 5,3
Table metering volume:
45
25
75
45
16
MX-F 25 25 50 25
5,
7,5 “B”
3
MX-F 45 45 90 45
MX-F 75 75 150 75
MX-F 105 105 210 105 No. of piston No. of Dim. “A” Dim. “B”
elements outlets (mm) (mm)
state: 09.14EN
(max.)
3 6 69,20 57,2
4 8 83,95 72,0
5 10 98,70 86,7
6 12 113,45 101,5
7 14 128,20 116,2
8 16 142,95 131,0
04-1-10-01
9 18 157,70 145,7
10 20 172,45 160,5
11 22 187,20 175,2
12 24 201,95 190,0
1090200390
piston).
Protection class: IP 65
The initial elements have a M10x1 thread connection Nominal power: ca. 30 W
at the distributor inlet as well as middle and end
elements at all distributor outlets. Order-no.: 401094010
(initial element, valve plate and solenoid valve)
Initial elements
Initial elements can be delivered with and without
38,5
30
inlet fitting.
5
Initial elements without inlet fitting, Assembly plate 50 x 50 x 5
Order-no.: 0800800929
Distance of fastening drillings: 17 mm must be ordered
Diameter of fastening drilling: 5,3 mm seperately.
Order-no.: 401094001 (standard)
Fastening
drilling 50,2 Fastening drills
14,85
Ø 5,3
17
7,5
Inlet
optional right
or left
M10x1
Ø 37
Inital element with elbow screw fitting WE6
M10x1k,
Distance of fastening drillings: 17 mm
Diameter of fastening drilling: 5,3 mm
Order-no.: 401094002
29 68
state: 09.14EN
Fastening
drilling
Solenoid valve
04-1-10-02
Initial element
Valve plate
1090200390
Progressive distributors
Fastening
drilling
Middle element Order-no.
MX-F 25 401095101
Ø 12
Ø 6,3
MX-F 45 401095102
MX-F 75 401095103
11,5
End element
M10x1
Fastening End elements are delivered with union screw and
30
drilling
olives for pipe Ø 6 mm
Ø 6,4
7,5
30
20
50
state: 09.14EN
04-1-10-03
1090200390
The middle and end element of a MX-F distributor screw, which separates the two sides, is removed
have always 2 outlets. and a screw plug is screwed into the side to be
closed. The metering volume of the locked side now
comes out of the other side, i.e. the metering volume
at the open side doubles.
Sealing screw AF 2
1 outlet per distributor disk
single single
Screw plug AF 5
double
Combination of outlets
Screw plug for closing outlets at the progressive
distributor MX-F
AF 5
Order-no.: 4010960050000
Separation of outlets
To separate combined outlets again, the sealing
screw has to be screwed in again.
AF 2
state: 09.14EN
Order-no.: 4010960060000
04-1-10-04
1090200390
Progressive distributors
single
large bearing points or main distributors e.g., there is
also the possibility to combine the outlets of several
distributor disks. single double
Screw Sealing
29
disks.
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
MX-F
Distributor bridges without outlet and pipe Three outlets combined at two different
distributor disks
bridge
Distributor bridges without outlet have the same
When outlets are combined with a pipe bridge
function as pipe bridges. With their help, three or four
Progressive distributors
triple
USIT-ring single
M10x1 10,4x14,7x1,2
NBR stainless steel
sealing screw
O-ring DIN 3771
10x1 NBR
Distributor bridge without outlet with non-return
valve,
Order-no., total: 4010 9600 10016
Hollow screw 29 Four outlets combined at two different
without outlet
with non-return valve 15 20,9 distributor disks
AF 13
Also four outlets can be combined with a pipe bridge
(standard) or a distributor bridge without outlet. To
14,75
29
Pipe bridge
quadruple
order-no. total: 4010960010011
Consisting of:
Screw
Union screw ÜS4 M10x1 plug
Order-no.: 0802000312
Sealing screw removed
Olive DKR 4
Order-no.: 09038620013
04-1-10-06
Reduction Ø6 to Ø4
Order-no.: 0802000310
Pipe bridge
1090200390
Middle elements 00 with proximity switch Technical data of the proximity switch
There is the possibility to install a middle element 00 Connection: M12x1 pluggable
with proximity switch into the MX-F progressive Thread connect. (at middle element): M11x1
distributor for monitoring purposes or for counting Switching type: PNP N/O contact
Operational voltage: 10 - 60 V DC
Progressive distributors
the piston strokes when clock cycle control is used.
einschl. Restwelligkeit
The middle element 00 has only one piston for Load capacity, permanent: 100 mA
signalling. Lubricant dosing is not possible with this short-term: 100 mA
middle element. Current consumption: < 15 mA
Ambient temperature: -25 °C to 70 °C
The middle element 00 can be placed at any point of Function display: yellow LED
the distributor, also later and when the distributor has Degree of protection: IP 67
already been used. The only thing to observe is, that Housing material: V4A (1.4571)
a MX-F 75 or MX-F 105 middle or end element must
follow up to a middle element 00. Wiring diagram
1 BN BN brown
2 1 +
The proximity switch can be delivered either with the 4 BK BK black
proximity switch on the right or on the left side. The 3 BL BL blue
3 4 -
side has to be determined in the order (see table).
Installation dimensions:
The proximity switch will be delivered with a cable of 14 A/F 10
0.3 m and with a M12x1 connector. Depending on
Ø
the intended use, bushings with different cable 6,
3
35,5
length can be used for the connector. Those have to
30
21
be ordered separately (see „Accessory progressive
14,5
SW 14
distributors“). Connector
M12x1 30
50
14,75
Middle element 00 Cable
with proximity
switch (right)
0,3 m length
L
Distributor MX-F
R
Sectional drawing:
state: 09.14EN
L = left 2 1
R = right
with NS
MX-F 00 right 401095001 the lubricant, which flows throuhg. The piston
left 401095000 approaches the proximity switch (2) and a signal is
released. This signal can be evaluated differently,
1090200390
Elements MX-F 75 and MX-F 105 with Progressive distributor with installed proximity
switch:
proximity switch
Mounting plate 50x50x5
Also middle and end elements MX-F 75 and MX-F
Order-no.:
105 can be delivered with a proximity switch 0800800929
Progressive distributors
Installation
Middle or end elements with proximity switch have to left
be indicated when the order is placed, a later
attachment of a proximity switch to an existing
middle- or end element is only possible by replacing 3
the concerned distributor disk.
15
5
5,5
1 BN BN brown
04-1-10-07
2 1 +
End element MX-F 75 NS 401096123022*
4 BK BK black
BL blue
End element MX-F 105 NS 401096124022*
3 4 3 BL -
* Please indicate the installation position of the proximity
1090200390
Progressive distributors
print out data. However, the visual stroke control can provide read or print out data. The pressure indicator
any time be retrofitted to the distributor. For this can be retrofitted any time, as it has only to be
purpose, the piston screw plug (1) is removed and screwed into the distributor outlets between the
the visual stroke control (2) is screwed in. This is only middle- or end element (1) and the retaining screw
possible at middle- and end elements MX-F 75 and (2) or into the distributor inlet between the threaded
MX-F 105. connection (3) and the initial element of the
progressive distributor.
The max. permissible operating pressure for the
outlet with visual stroke control is 40 bar. Screwed into the
distributor inlet:
Pressure indicator
Order-no.: 4350 00 105 3 (not pressurized)
1
2
5
state: 09.14EN
3 6 5
AF 11
5,5
11
The installation of an indicator pin is also only
possible in middle elements as well as in end
Piston element with Outlet Order-no.
elements MX-F 75 and MX-F 105 and has to be
indicator pin pipe-Ø
indicated when the order is placed.
(mm)
Middle element MX-F 75 6 401095153*
The indicator pin is attached on the right as a Middle element MX-F 105 6 401095154*
standard. An installation on the left has to be End element MX-F 75 6 401096153*
indicated separately. End element MX-F 105 6 401096154*
FAZ03168_03
connected to the progressive distributor’s piston (2).
Proximity switch housing
With each stroke, the stamp (1) is either compulsory Drawing: F0409/19-09
pushed out or drawn back.
Proximity switch M12x1
(10 - 60 V DC)
Order-no.: 100091865
1
The proximity switch is preadjusted during the
state: 09.14EN
1090200390
Progressive distributors
added or some become unnecessary, the distributor
can be extended or shortened by mounting the distributor between the individual elements be
additional distributor disks or removing unnecessary damaged and does not seal anymore, a set of seals
ones. can be ordered, containing all O-rings installed into
the MX-F distributor.
Description:
Set of seals for initial elements:
- Remove the connecting rods (1), which keep the Order-no.: 4010960030002
distributor together
- Separate the distributor at the desired point Set of seals for middle elements:
- Add new distributor disks or remove the Order-no.: 4010960030001
unnecessary ones
- Screw the distributor together again with the
corresponding connecting rods and one tooth
lock washer each (see table)
Torque 10 ±1 Nm
75*
25
45
45
75
When the name of the fitting is missing, retaining side (standard) or on the left side of MX-F
screws Ø 6, or, for the installation of a proximity distributors.
switch, non-return valves with cutting rings Ø 6 are
delivered.
04-1-10-12
1090200390
Order examples of two distributors, one with proximity switch at middle elment 00 and one with proximity
switch at end element MX-F 75
Middle element 00
with proximity switch
Screw (no dosing)
Progressive distributors
75*
plug
Distributor
outlet
Distributor M10x1 75*
outlet M10x1
45
Distributor bridge
with outlet Screw 25*
M10x1 plug
with non-return
valve
L R
Position of (See „Accessory
connections progressive distributor”for cable)
L = left Inlet
R = right fitting
* = Sealing screw removed!
Inlet fitting
Outlet fittings
Pos. of connections
1090200390
Precharge valve
e.g. straight
2 monitored
lube points
board
If pressure is reduced due to line break, the pin of the Button
pressure indication becomes invisible and the Actuation
lever
electrical circuit is interrupted.
Actuation
piston
Attention: To ensure a reliable function, the value of
the pressure loss in the connecting line between
04-1-10-14
Progressive distributors
Outlet
ca. 113
M10x1
63
39
23,5
* Dimensions depends at which distributor outlet the first or Attention: Dimensions of distributor MX-F see description
the last line break element is installed. MX-F dimensional drawing
Technical data
Operating pressure inlet: max. 300 bar
Operating voltage: 10 - 55 V DC
Contact capacity: 50 mA DC
state: 09.14EN
5
Progressive distributors
10 2
9
8
Thread
lube point 1
Progressive distributor MX-F
4
7
10 2
2
12
7
8
2
9 11
Thread
1 8 lube point
Table of order numbers of individual components of Order number table for connecting rod (Pos. 7) for
line break monitoring for MX-F (see figure above): MX-F (1 pcs):
Position Designation Order-no.
1 Inlet flange, 437501010100 Number of line
plug M12x1 break elements Connect. Order-no.
2 Line break element 437502010100 or intermediate rod
3 Final plate 4375060100 plates
4 Intermediate plate 4375040100 1 M4 x 70 F4375/21-01 001
5 Connection cable 1000913864 2 M4 x 85 F4375/21-01 002
state: 09.14EN
Ø6
Straight
Precharge Thread Order-no. precharge
valve
G
valve G
straight M8x1k 43750706A111
Progressive distributors
(Pos. 10*) M10x1k 43750706A211 ca. 57
Ø6
M8x1k 43750706B111
M10x1k 43750706B211 Elbow
7,5
precharge
30
swivelling M10x1k 43750706B311
valve
precharge valve (lang)
(Pos. 11*) R 1/8”k 43750706B411 G
R 1/4”k 43750706B511
ca. 57
1/8-27NPT 43750706B611
Ø6
elbow M8x1 43750706C111
Swivelling
5,5
precharge valve M10x1 43750706C211
26,5
precharge
(Pos. 12*) G 1/8 43750706C311 valve
* see individual compontents of line break monitoring G
state: 09.14EN
04-1-10-17
1090200390
transparent
cap
Screw Code
plug number
75*
75
45*
Inlet
25 flange
plug
M12x1
L R
Connection position
Metering code-no. at outlets
04-1-10-18
1090200390
Progressive distributors
extended or shortened. Due to the disk construction Middle element code number
there is the possibility to join individual middle (metering element)
elements ( metering element s ) with different
Initial element
metering volumes together to one complete
progressive distributor.
23,5
11,35
Ø 10 M10x1 inlet
Ø 5,3
state: 09.14EN
105
75
45
MX-I
MX-I
MX-I
MX-I
3 6 73,95 62,25
17
XXX
XXX
XXX
XXX
4 8 88,70 77,00
5 10 103,45 91,75
6 12 118,20 106,50
04-1-12-01
7 14 132,95 121,25
7,5 “B”
8 16 147,70 136,00
“A”
1090200390
Initial element
Initial elements can be delivered with and without
Ø 6,3
inlet fitting.
Ø 12
30
Initial element without inlet fitting,
14,5
11,5
Distance of fastening drilling: 17 mm
Diameter of fastening drilling: 5,3 mm
M10x1
Material: V4A (1.4404) Fastening
30 bores
Order-no.: 3979A010 (Standard)
Ø 6,4
30
Fastening bores
7,5
20
50
1090200390
Progressive distributors
The individual disks have two outlets. the sealing screw, which separates the two sides, is
removed and a screw plug with sealing ring is
screwed into the side that has to be closed. The
metering volume of the sealed side now comes out of
the other side, i.e. the metering volume at the open
Sealing screw AF 2
side doubles.
single single
Sealing screw AF 5
with O-ring
double
Combination of outlets
Sealing screw with O-ring for sealing of outlets:
Sealing screw
removed
AF 5
Order-no. complete:
Screw plug M10x1, V4A (1.4571), with sealing:
040301583013
Separation of outlets
In order to separate combined outlets of a middle
element the sealing screw has to be screwed in
again.
Order-no.:
Sealing screw: 0802000455
04-1-12-03
1090200390
Combination of outlets at several middle Three outlets combined at two middle elements
To connect three outlets at two adjacent middle
elements
elements, the sealing screw of one middle element
Should the total metering volume of the combined
has to be removed and the outlet opposite the
outlets at one middle element be insufficient, at very
distributor bridge has to be closed with a screw plug
Progressive distributors
tripple
bridge’s outlet.
quadruple
double
single
Sealing screw Distributor bridge
1090200390
with outlet
Subject to alterations! © BEKA 2014 All rights reserved!
BAIER + KÖPPEL
BEKA Nederland GmbH + CO KG Wagenmakerij
B.V. BEETHOVENSTR.11 14 POSTFACH tel.1320 TEL.: +49 9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK 4762 D-91257 PEGNITZ
AV Zevenbergen D-91253 PEGNITZ FAX: +49 9241 729-50
fax. 0168 338 329 E-MAIL: beka@beka-lube.de
www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
MX-I
Distributor bridges without outlet Three outlets combined at two middle elements
Three or four outlets at different adjacent distributor At least three outlets are concerned when combining
disks can be combined with the help of distributor outlets with a distributor bridge without outlet, as the
bridges without outlets. metering volume of one middle element has to be
directed through the middle element of a progressive
Progressive distributors
Order-no. complete: 4096960010013 distributor. The sealing screw of one middle element
Material: V4A (1.4404) always has to be removed.
Banjo bolt 20
without outlet 15 12,9
A/F 5
Sealing screw
removed
14,75
29
triple
USIT-Ring single
M10x1 10,4x14,7x1,2
NBR stainl. steel
Sealing screw Distributor bridge
O-ring DIN 3771 without outlet
10x1 NBR
Distributor bridge without outlet, with non-return
valve Four outlets combined at two middle elements
Order-no. complete: 4096960010016 Four outlets at two adjacent middle elements can be
Material: V4A (1.4404) combined by means of a distributor bridge wihout
outlet. The sealing screws of both middle elements
Banjo bolt 29
without outlet have to the removed and one outlet opposite the
with non-return valve 15 20,9
distributor bridge has to be closed with a screw plug
AF 13
and sealing ring.
14,75
29
quadruple
When using a MX-I 3/2 that combines three outlets, a
state: 09.14EN
15
5
50 26
at the distributor (see dimensional drawing on the
13
right) a mounting plate (see drawing) has to be put
under distributors which are not attached with a
11
1 BN
+ BN brown MX-I 75 NS right 3979M230N10
2 1
4 BK BK schwarz left 3979M230N20
3 BL BL blau MX-I 105 NS right 3979M330N10
3 4 -
1090200390
left 3979M330N20
Subject to alterations! © BEKA 2014 All rights reserved!
BAIER + KÖPPEL
BEKA Nederland GmbH + CO KG Wagenmakerij
B.V. BEETHOVENSTR.11 14 POSTFACH tel.1320 TEL.: +49 9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK 4762 D-91257 PEGNITZ
AV Zevenbergen D-91253 PEGNITZ FAX: +49 9241 729-50
fax. 0168 338 329 E-MAIL: beka@beka-lube.de
www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
MX-I
Pipe-Ø 6
The progressive distributors MX-I can also be
equipped with an indicator pin.
Progressive distributors
The indicator pin cannot be attached later.
Retrofitting an indicator pin is only possible by AF 9
5,5
replacing a distributor disk.
Order-no. 3979600010000
2
04-1-12-07
1090200390
105
105
75
MX-I
MX-I
MX-I
XXX
XXX
XXX
Progressive distributors
delivered already installed into the distributor, then
please indicate this with the type of fitting, the pipe comes out and they have to be separated by a slash
diameter and the series. (/). For distributor bridges, a plus (+) has to be
indicated instead of the slash.
Outlets Designation
M10x1 Without fitting
ÜS06 Union screw, pipe-Ø 6
RVA Non-return valve, internal thread
M10x1 (without olive and union
screw)
RVA06 Non-return valve, pipe-Ø 6
(with olive and union screw)
Order example
Progressive distributors
Mounting plate
has to be ordered
separately Non-return
M10x1
(see “elements with Lock screw valve
proximity switch”)
Connection
position
L = left L
R = right
*
105
105
75
45
MX-I
MX-I
MX-I
MX-I
XXX
XXX
XXX
XXX
Inlet
fitting
R
Distributor
bridge
with outlet M10x1
Proximity switch
(See “Accessory
progressive distributor for cable”)
* = Sealing screw removed!
1090200390
Progressive distributors
The progressive distributor LX-2 and LX-3 are built in Middle element Piston
a variable disk construction. Therefore the distributor Initial element element
can be, depending on the number of lubrication
points, extended or shortened.
A progressive distributor needs at least three pistons
for function, i.e. an initial and end element as well as
a middle element for distributor LX-2 and LX-3.
Technical data
Operating pressure inlet: max. 300 bar Distributor Distributor outlets
Temperature range: -30 °C to 80 °C inlet
23
15,7
15
8
M10x1 inlet
state: 09.14EN
Ø 6,3
Ø 6,4
Ø 12
200
200
200
LX-2
LX-2
LX-2
LX-2
3 6 60,00
20
18
XXX
XXX
XXX
XXX
4 8 74,75
5 10 89,50
6 12 104,25
04-1-14-01
7 14 119,00
8 16 133,75
6 9 18 148,50
1090200390
“A” 10 20 163,25
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
LX-2 / LX-3
Initial element
for LX-2 order-no.: 3972970000
for LX-3 order-no.: 3973970000
Middle element
for LX-2 order-no.: 3972980000
for LX-3 order-no.: 3973980000
O-ringe
Distributor outlets
M10x1
End element
for LX-2 order-no.: 3972990000
for LX-3 order-no.: 3973990000
state: 09.14EN
04-1-14-02
Distributor outlets
M10x1
1090200390
Progressive distributors
The individual disks have two outlets. screw, which separates the two sides, is removed
and a screw plug is screwed into the side to be
closed. The metering volume of the locked side now
comes out of the other side, i.e. the metering volume
Sealing screw AF 2
at the open side doubles.
single single
Screw plug AF 5
double
Combination of outlets
Screw plug M10x1 for closing outlets:
AF 5 AF 5
Order number
for LX-2 (ZnNi): 3976960050000
for LX-3 with sealing (1.4571): 040301583013
Separation of outlets
To separate combined outlets again, the sealing
screw has to be screwed in again.
AF 2
state: 09.14EN
Order number
for LX-2 and LX-3 sealing screw: 0802000455
04-1-14-03
1090200390
Hollow screw 31
with outlet M10x1
AF 13 15 23,9 Four outlets combined at two different
distributor disks
single
04-1-14-04
Distributor bridges without outlet and pipe Three outlets combined at two different
distributor disks
bridge
When outlets are combined with a pipe bridge
Distributor bridges without outlet have the same
(standard) or with a distributor bridge without outlet,
function as pipe bridges. With their help, three or four
at least three outlets are always concerned, as the
Progressive distributors
outlets at different, adjacent distributor disks can be
metering volume has to be directed through one of
combined.
the disks of the progressive distributor. The sealing
screw always has to be removed in one of the two
Order number total:
combined distributor disks.
for LX-2 (ZnNi): 3976960010013
for LX-3 (V4A, 1.4404): 4096960010013
Hollow screw 20
without outlet 15 12,9 triple Sealing screw removed
AF 5
14,75
29
USIT-ring
M10x1 12,9
10,4x14,7x1,2
NBR stainless steel 20
Hollow screw quadruple
Distributor
without outlet O-ring DIN 3771
bridge
state: 09.14EN
AF 5 10x1 NBR
without
outlet
When LX-2 3/2 bzw. LX-3 3/2 are used where three
outlets are combined, a distributor bridge without
outlet but with integrated non-return valve has to
be used.
04-1-14-05
1090200390
LX-2 Cable Ø 5 mm
XXX 200
length 0,3 m
LX-2
Technical data of proximity switch XXX 200
Order number
Circuit diagram Proximity switch with 0,3 m cable and plug M12x1
1000912960
state: 09.14EN
1 BN BN brown
2 1 +
4 BK BK black
3 BL BL blue
3 4 -
04-1-14-06
1090200390
Extension or shortening of distributors Note: A LX-2 and LX-3 distributor always has to
The distributorsLX-2 und LX-3 can any time be consist of at least 3 piston elements and
adapted to the application conditions because of 10 as a maximum.
their disk construction. If new lubrication points
Should one of the O-rings, which are used for sealing
Progressive distributors
should be added or some become unnecessary, the
distributor can be extended or shortened by the distributor between the individual elements be
mounting additional distributor disks or removing damaged and does not seal anymore, a set of seals
unnecessary ones. can be ordered, containing all O-rings installed into
the LX-2 or LX-3 distributors.
Description:
Set of seals for initial elements:
- Remove the cylinder screws, which keep the Order-no.: 397297D001
distributor together
- Separate the distributor at the desired point Set of seals for middle elements:
- Add new middle elements or remove the Order-no.: 397298D001
unnecessary ones
- Screw the distributor together again with the
corresponding cylinder screws with internal
hexagon socket and one tooth lock washer each
(see table)
Shown is a LX-2 3/6 or LX-3 3/6 distributor that is Attention: Take care of utmost cleanness.
enlarged by a middle element:
200
200
LX-2
LX-2
LX-2
XXX
XXX
XXX
04-1-14-07
Order key When the description of the fitting is missing, the LX-
Distributor inlet 2 is delivered without fittings and the LX-3 with union
The LX-2or LX-3 distributor can be delivered with or screw Ø 6.
without fittings. If the inlet fitting shall already be
Metering volume
Progressive distributors
Outlets Designation
M10x1 without fitting
ÜS06 union nut, pipe-Ø 6
RVB06 non-return valve, pipe-Ø 6
(with cutting ring and union nut)
RVS06 Attention: only possible for LX-2
state: 09.14EN
Order example
Progressive distributors
Proximity switch with 0,3 m cable
Outlet Ø 5 mm and bush M12x1
Piston elements
fitting (cable see accessories progressive
distributor)
200 XXX
LX-2
* 200 XXX
* 200 XXX
LX-2
Distributor bridge
200
LX-2
XXX
without outlet
with non-return valve
Code L R Connection
number position
L = left
R = right
Inlet fitting
* = Sealing screw removed
1090200390
Progressive distributors
depending on the number of lubrication points. The elements
Initial element
disk construction offers the possibility to make up a
complete progressive distributor of individual
elements (initial-, middle- and end elements) which
have different dosage volumes.
Dimensional drawing:
Technical data
Operating pressure at inlet: max. 300 bar 22,25 14,75 23
M10x1 Inlet
23
16,5
15
Material: steel,
8
Zinc-Nickel-coating acc. to DIN 50979
No. of piston elements:
Ø 13,9
Ø 6,3
Ø 6,4
min. 3 piston elements: LX-4 3/6
max. 10 piston elements: LX-4 10/20
150
100
200
50
LX-4
LX-4
LX-4
LX-4
18
XXX
XXX
XXX
XXX
7 14 119,00
8 16 133,75
9 18 148,50
10 20 163,25
1090200390
Initial element
Inlet O-rings
Outlets
M10x1
M10x1
Middle element
Middle element Order-no.
LX-4 50 3950981000
LX-4 100 3950982000
LX-4 150 3950983000
LX-4 200 3950984000
O-rings
Outlets
M10x1
End element
state: 09.14EN
1090200390
Progressive distributors
A progressive distributor element has two outlets. the side to be closed.
The dosage volume of the closed side will now
escape at the other side, i.e. the dosage volume
doubles here.
Sealing screw A/F 2
simple simple
double
Combination of outlets
Screw plug for the closure of outlets:
A/F 5
Order number
Screw plug M10x1 (ZnNi): 3976960050000
Separation of outlets
In order to separate combined outlets again, the
sealing screw has to be screwed in again.
A/F 2
Order number
Sealing screw 0802000455
state: 09.14EN
04-1-16-03
1090200390
Simple
31 Sealing screw Distributor
Hollow screw
bridge with
with outlet M10x1 15 23,9 outlet
A/F 13
Distributor
bridge with
outlet
Simple Double
04-1-16-04
Progressive distributors
Order-no. complete: 3976960010013
Material: ZnNi sealing screw of one of the combined elements must
always be removed.
Hollow screw 20
without outlet 15 12,9
A/F 5 Sealing screw removed
Triple
14,75
29
plug
USIT-ring
M10x1 10,4x14,7x1,2 12,9
Hollow screw NBR stainless steel 20
without outlet Quadruple Distributor bridge
A/F 5 O-ring DIN 3771
10x1 NBR without outlet
state: 09.14EN
progressive distributor.
8
Technical data of the proximity switch:
Connection: M12x1 pluggable LX-4
XXX 150
switch
incl. residual ripple LX-4
XXX 100
Current-carrying capacity,
LX-4
Permanent: 100 mA XXX 200
Short-term: 100 mA
45,4
Current consumption: < 15 mA
Ambient temperature: -25 °C to 70 °C
Function display: LED yellow
Degree of protection: IP 67
Housing material: V4A (1.4571)
Threaded connection: M11x1 Order number
Proximity switch with cable of 0.3 m length and
Wiring diagram M12x1 plug: 1000912960
state: 09.14EN
1 BN BN brown
2 1 +
4 BK BK black
3 BL BL blue
3 4 -
04-1-16-06
1090200390
Progressive distributors
unnecessary, the distributor can easily be extended
or shortened by adding middle elements or removing between the individual elements is damaged and
them. does not seal properly any longer, a sealing kit
containing all O-rings of the progressive distributor
Description LX-4 can be ordered.
The figure shows a 3/6 LX-4 progressive distributor Achtung: Bei diesen Arbeiten unbedingt auf
to be extended by one middle element. äußerste Sauberkeit achten.
200
50
LX-4
LX-4
LX-4
XXX
XXX
XXX
04-1-16-07
1090200390
Outlets Designation
M10x1 without fitting
ÜS06 union nut, pipe-Ø 6
RVB06 non-return valve, pipe-Ø 6
(with cutting ring and union nut)
RVS06 non-return valve, plug-type,
for pipe-Ø 6
state: 09.14EN
1090200390
Order example
Progressive distributors
Screw plug
Outlet
fitting
L
Piston elements
100
50
LX-4
LX-4
LX-4
LX-4
XXX
XXX
Inlet
fitting
R
Näherungsschalter
Position of mit 0,3 m langem Kabel Ø 5 mm
connections und Buchse M12x1
L = left (Kabel siehe “Zubehör
R = right Distributor bridge Progressivverteiler”)
with outlet
Inlet fitting
Outlet fittings
Pos. of connections
Dosage code numbers at the outlets
04-1-16-09
1090200390
1090200390
Progressive distributors
extended or shortened. Because of the dis k
number
construction, there is the possibility to form individual 0
1-2
middle elements (metering elements) with different SX
0
1-1
SX
metering volumes to one complete progressive
SX
1-2
0
distributor. 0
1-2
SX
SX
1-1
0
SX
The different metering volume per stroke is effected 0
1-2
by different piston diameters.
outlet
No. of revolutions: max. 180 r/min
G1/8
Ø15
24,85 19,7 19,7
Material: steel, galvanized
Ø15
40
min. 3 middle elements: SX-1 3/6
15
SX-1 05 68 136 05
SX-1 10 105 210 10
SX-1 15 150 300 15 Ø6
SX-1 20 210 420 20 “A”
state: 09.14EN
7 14 172,9 152,9
8 16 192,6 172,6
9 18 212,3 192,3
10 20 232,0 212,0
1090200390
Elements
The progressive distributors SX-1 have an initial
element (without piston), three to ten middle
elements (with piston) and one end element (without
Progressive distributors
piston).
Initial element
Order-no.: 4000 97 0000 End element
Order-no.: 4000990000
with 4000983000001
SX-1 20 without 4000984000
with 4000984000001
SX-1 25 without 4000985000
with 4000985000001
SX-1 35 without 4000986000
with 4000986000001
SX-1 45 without 4000987000
04-1-20-02
with 4000987000001
1090200390
Progressive distributors
The middle elements have two outlets each. be screwed in again tightly.
single single
Combination of two opposite outlets at
one middle element
When two opposite outlets at a middle element are
combined, the aluminum seal is removed and the
interchangeable seal washer, which separates the
two outlets, is turned over. One of the two outlets is
Aluminum seal closed with a screw plug and a sealing ring. The
metering volume of the closed side then comes out
Spare parts: of the opposite outlet, i.e. the metering volume of the
open side doubles.
Screw plug G 1/8:
Order-no.: 090090800313 A/F 5
Aluminum seal
Order-no.: 0800820011
Aluminum seal
Turning over the interchangeable seal washer removed
state: 09.14EN
-
Note: Please take care of utmost cleanness
when working at the distributor.
1090200390
Combination of adjacent outlets at several For the distributor size SX-1 3/2, at which three
outlets shall be combined, a distributor bridge with
middle elements
outlet and with integrated non-return valve is used.
Should the total metering volume of the combined
outlets at one middle element be insufficient, at very
Progressive distributors
large bearing points or at main distributors e.g., there Two adjacent outlets combined at two middle
is the possibility to combine the outlets of two or more elements
middle elements. To connect two outlets on one side, at different
adjacent middle elements with the help of a
For this purpose, the outlets of two middle elements distributor bridge with outlet, the interchangeable
are on one side connected with a distributor bridge seal washers of both concerned middle elements are
with or without outlet. Depending on the fact, if or in not turned over. The metering volumes of the
which element the interchangeable seal washer is connected outlets come out of the distributor bridge’s
turned over, two, three or four outlets are connected outlet.
this way. The closed outlets’ metering volume then
comes out of one outlet. Interchangeable seal washer
single
30,5
Hollow screw Three outlets combined at two middle elements
with outlet G 1/8 15 25,7
AF 12 To connect three outlets with a distributor bridge with
outlet, the interchangeable seal washer at one of the
two concerned middle elements has to be turned
19,7
35
G 1/8
35
04-1-20-04
Four outlets combined at two middle elements For the distributor size SX-1 3/2, at which three
When four outlets should be connected with one outlets shall be combined, a distributor bridge with
distributor bridge with outlet, the two outlets opposite outlet and with integrated non-return valve is used.
to the distributor bridge each have to be closed with a
screw plug with sealing ring. The interchangeable Three outlets combined at two middle elements
Progressive distributors
seal washers in both middle elements have to be As a middle element must not be closed on both
turned over and the aluminum seal has to be sides without directing the lubricant to another outlet,
removed. at least three outlets have to be connected with
The metering volumes of the four outlets then come distributor bridges without outlet. Therefore the
out of the outlet of the distributor bridge. interchangeable seal washer in one of the middle
elements has to be turned over and the Al-sealing
has to be removed.
Screw plug with
Interchangeable seal washer sealing ring The metering volumes of the three connected outlets
turned over
then come out of the middle element’s open outlet, at
which the interchangeable seal washer has been
turned over.
Quadruple
Interchangeable seal washer
turned over,
Al-seal removed
Triple
Distributor bridge without outlet
Order-no. complete: 4000980010010
single
20
15 15,2
G 1/8
Interchangeable Al-seal
seal washer
19,7
Hollow screw 20
with outlet 15 15,2 bridge.
AF 12
Interchangeable seal washer
turned over,
Screw plug with
Al-seal removed
sealing ring
19,7
35
G 1/8
04-1-20-05
34,5 60
max.
3,5
7,5
Open housing
with proximity switch
40
7,5
Ø 12,5
Progressive distributors
visual stroke control can any time be retrofitted. For
this purpose the piston screw plug is removed and
the visual stroke control is screwed in. This is
AF 13
possible at all middle elements.
Order-no.: 435000110
Visual
stroke control
Functional description:
When the piston (1) is actuated, the control pin (2) is
shifted outwards (in the shown example to the left)
and becomes visible. The control pin is pushed back
into its original position by the spring (3) as soon as
the piston is moved to the other side (see technical
basics “Functional description for disk
construction”).
state: 09.14EN
3 2 1
04-1-20-07
1090200390
Solenoid valve (special accessory) Table of order no. for connecting rods (à 1 piece):
A solenoid valve can be installed at progressive Distributor Conn. rod Order-no.
distributor SX-1. SX-1 3/6 M7 x 176 002141016
SX-1 4/8 M7 x 196 002141017
SX-1 5/10 M7 x 216 002141018
Progressive distributors
approx. 153,7
Initial element
Distributor
inlet
15
Order-no.:
Initial element ..................................... 4000970001
29,5
24 V DC
37
Solenoid valve GR 2-1-W110 ................. 04101004
110 V AC
Solenoid valve GR 2-1-W220 ................. 04101005
220 V AC
04-1-20-08
Progressive distributors
should be added or some become unnecessary, the
distributor can be extended or shortened by the the distributor between the individual elements be
installation or removal of middle elements. damaged and does not seal any more, a set of seals
can be ordered. It contains all O-rings that are
Description: installed in SX-1 distributors.
- screw off the cap nuts of both ends of the
connecting rods and take the connecting rods Set of seals for middle elements:
out Order-no.: 4000 98 D000
- separate the distributor at the desired point
- add the new middle elements or remove the Set of seals for initial element:
unnecessary ones Order-no.: 4000 97 D000
- screw the distributor together with the
connecting rods and the cap nuts (see table)
Connecting rods M7
Best.-Nr.: see table
SX1---15
Pressure indicator
The pressure indicator locates closed lubrication
lines, respectively blocked progressive distributors.
Progressive distributors
Installation:
The pressure indicator is screwed into a swivelling
fitting (4) and then into the distributor. The
connection fitting has to be screwed into the
swivelling fitting.
Functional description:
When the pressure increases, the pin (1) is pushed
out and the indicator pin (3) becomes visible. When
the pressure is reduced, the spring (2) pushes back
the indicator pin (3).
3
2
state: 09.14EN
1
4
Progressive distributors
delivered already installed into the distributor, they
have to be marked with the pipe diameter and the have to be separated by a slash (/). For distributor
series. (see table) bridges, a plus (+) has to be indicated instead of the
slash.
Inlet Designation
G1/8 without fitting The metering code numbers of combined outlets
GE06LL male stud coupling, accumulate (see “Combination of outlets”).
GE06L pipe-Ø 6 or 8,
GE08LL series L or LL Screw plugs and outlets which are closed with
The fittings can also be ordered separately (see distributor bridges are marked with a dash (---). The
“Accessories progressive distributor” or “Fittings and interchangeable seal washer that has to be turned
accessories”). over is marked with an asterisk (*) in the drawing
(see “Combination of outlets”).
When there is no indication concerning the fittings,
delivery is without fittings as standard! Proximity switches (=NS)
Middle elements to which proximity switches should
Distributor outlet be attached, have to be marked with NS or NSg after
The fitting type at the distributor outlets has to be the number for the metering volume. At SX-1
indicated with the diameter and the series when the distributors, proximity switches can be installed on
order is placed (see table): the left or on the right side, as desired. However the
Outlets Designation standard installation position is on the right side.
G1/8 without fitting
GE06LL male stud coupling,
NS Designation
GE06L pipe-Ø 6 or 8,
NS NS with open housing (standard)
GE08LL series L or LL
NSg NS with closed housing
RGE06LL non-return valve,
RGE06L pipe-Ø 6 or 8,
RGE08LL series L or LL
RGE08L
Note:
Without an indication of the series, a male stud
coupling, respectively a non-return valve of the
series L (cutting ring) is delivered as standard.
state: 09.14EN
Order example
35*
25
Screw plug
10*
Outlet
G1/8
1090200390
Progressive distributors
points, extended or shortened. Because of the disk Metering code number
construction there is the possibility to form individual
middle elements (metering elements) with different
metering volumes to one complete progressive
distributor.
outlets
G 1/8
SX-3 max. 60 r/min 29,65 19,7 Ø 6,4
41
31,7
16,9
Max. 10 metering elements: SX-2 or SX-3 10/20 “A” SX-2 mit cylinder screw
or connecting rod
(max. up to 12 metering elements possible on
Ø 15
Elements
The progressive distributors SX-2 and SX-3 always
consist of one initial element (without piston), three
to ten middle elements (with piston) and one end
Progressive distributors
SX-3 38 4008986000
SX-3 47 4008987000
* Material of middle element SX-3: V2A (1.4301)
1090200390
Progressive distributors
The progressive distributor’s individual middle To separate combined outlets at progressive
elements have two outlets. distributors again, a new aluminum seal has to be
laid in, the interchangeable seal washer has to be
Interchangeable seal turned over and the washer attachment screw has to
Aluminum washer Washer attachment be screwed in again tightly.
seal screw
Aluminum seal
Aluminum seal removed
state: 09.14EN
Combination of outlets at several middle Two adjacent outlets combined at two middle
elements
elements
To connect two outlets on one side, at different
Should the total metering volume of the combined adjacent middle elements with a distributor bridge
outlets at one middle element be insufficient, at very with outlet, the interchangeable seal washers of both
Progressive distributors
large bearing points or main distributors e.g., there is concerned middle elements are not turned over. The
the possibility to combine the outlets of two or more metering volumes of the connected outlets come out
middle elements. of the outlet of the distributor bridge.
For this purpose, the outlets of two middle elements
are on one side connected with a distributor bridge
with or without outlet. Depending on the fact, if or in
which element the interchangeable seal washer is Interchangeable seal washer
turned over, two, three or four outlets are connected single
Double
Distributor bridge with outlet single
Aluminum seal
Hollow screw 30,5
with outlet G 1/8
15 25,7
AF 12
Four outlets combined at two middle elements Three outlets combined at two middle elements
When four outlets should be connected with one As a middle element must not be closed on both
distributor bridge with outlet, the two outlets opposite sides without directing the lubricant to another outlet,
to the distributor bridge each have to be closed with a at least three outlets have to be connected with
screw plug with sealing ring. The interchangeable distributor bridges without outlet. Therefore the
Progressive distributors
seal washers in both middle elements have to be interchangeable seal washer in one of the middle
turned over and the aluminum seal has to be elements has to be turned over and the Al-sealing
removed. has to be removed.
The metering volumes of the four outlets then come The metering volumes of the three connected outlets
out of the distributor bridge’s outlet. then come out of the middle element’s open outlet, at
which the interchangeable seal washer seal has
Interchangeable seal washer Screw plug with
turned over sealing ring been turned over.
single
and SX-3.
7,5
40
9
to be ordered separately (see “Accessory
max.
progressive distributor”).
3,5
16,65
Open housing
45
32
7,5
Ø 12,5
Progressive distributors
visual stroke control can any time be retrofitted. For
this purpose the piston screw plug is removed and
the visual stroke control is screwed in. This is AF 13
possible at all middle elements.
Order-no.: 435000110
Visual stroke
control
Functional description:
When the piston (1) is actuated, the control pin (2) is
shifted outwards (in the shown example to the right)
and becomes visible. The control pin is shifted back
into its normal position by the spring (3) as soon as
the piston is moved to the other side (see technical
basics “Functional description for disk
construction”).
state: 09.14EN
1 2 3
04-1-30-07
1090200390
Description:
- Screw off the hexagon nuts (2, respectively 6) at
the cylinder head cap screws (1), or at the The SX-2 distributors and from five middle elements
connecting rods and take out the cylinder head on also the SX-3 distributors are assembled with
cap screw or the connecting rods connecting rods:
- Separate the distributor at the desired point
- Add the new middle elements or remove the 5 (SX-2) 4 (SX-2) 5 (SX-2)
unnecessary ones 7 (SX-3) 6 (SX-3) 7 (SX-3)
- Screw the distributor together with the
corresponding cylinder head cap screws,
respectively the connecting rods and the hexagon
nuts (see tables)
3 (SX-2) 3 (SX-2)
8 (SX-3) 8 (SX-3)
Note: Please pay attention to utmost
cleanness when working at
distributors. Distributor SX-2:
Pos. 1 Cylinder head cap screw with internal
Tab. 1 order-no. for cylinder screw with internal
socket DIN 6912-M8-10.9, see order-no. in table 1
hexagon socket DIN 6912 (1 pcs) for SX-2:
Pos. 2 Safety hexagon nut, DIN 980 - M8 - St
Distributor Cylinder scr. Order-no. Order-no.: 090098000153 (1 piece)
SX-2 3/6 M8 x 110 090691204223
SX-2 4/8 M8 x 130 090691204323 Pos. 3 Washer DIN 125 - B 8,4 - St
Order-no.: 0900125004132 (1 piece)
Tab. 2 order-no. for Zugstangen (1 Stück) for SX-2:
Pos. 4 Connecting rods M8 - St, see order-no. in
Distributor Conn. rod Order-no.
SX-2 5/10 M8 x 166 0802000552 table 2
SX-2 6/12 M8 x 183 0802000553 Pos. 5 Hexagon nut, self locking
SX-2 7/14 M8 x 203 0802000554 DIN 982 - M8 - St
SX-2 8/16 M8 x 223 0802000555
SX-2 9/18 M8 x 242 0802000556 Order-no.: 090098200213 (1 piece)
SX-2 10/20 M8 x 262 0802000557 Distributor SX-3:
state: 09.14EN
Tab. 3 order-no. for conn. rods (1 pcs) for SX-3: Pos. 6 Connecting rods M8 - V4A, see order-no.
Distributor Conn. rod Order-no. in table 3
SX-3 3/6 M8 x 124 0802000500 Pos. 7 Hexagon nut, self locking
SX-3 4/8 M8 x 144 0802000501
DIN 985 - M8 - V4A
SX-3 5/10 M8 x 166 0802000502
SX-3 6/12 M8 x 183 0802000503 Order-no.: 090098500741 (1 piece)
SX-3 7/14 M8 x 203 0802000504 Pos. 8 Washer DIN 125 - B8,4 - V4A
04-1-30-08
Note: SX-2 and SX-3 distributors always have Pressure indicator (only for SX-2)
to consist of at least three middle The pressure indicator locates closed lubrication
elements and up to ten as a maximum. points, respectively blocked progressive
distributors.
Should one of the O-rings, which are used for sealing
Progressive distributors
the distributor between the individual elements be The indicator can be used in the distributor inlet as
damaged and does not seal any more, a set of seals well as in the distributor outlets for blockade
can be ordered containing all O-rings used in SX-2, monitoring of individual lubrication points and series-
respectively SX-3 distributors. connected progressive distributors (secondary
distributors).
Set of seals for middle elements:
Order-no.: 3989 98 D000 The pressure indicator can any time be retrofitted..
Screwed into the
Set of seals for initial elements: distributor outlet:
Order-no.: 3989 97 D000 pressure indicator
(pressurized)
Installation:
The pressure indicator is screwed into a swivelling
fitting (4) and then into the distributor. The
connection fitting has to be screwed into the
swivelling fitting.
Functional description:
When pressure increases, the pin (1) is pushed out
and the indicator pin (3) becomes visible. When
pressure is reduced, the spring (2) pushes back the
indicator pin (3).
3
2
state: 09.14EN
1
4
Note:
Without indication of the series, a straight fitting,
state: 09.14EN
1090200390
Order example
Distributor
Progressive distributors
bridge
30*
with outlet
G1/8 17
23*
Outlet
closed
Proximity
switch
(cable, see
L Inlet fitting Ø 6 L R “accessories
progessive
distributor)
Connection positions
state: 09.14EN
04-1-30-11
1090200390
1090200390
Progressive distributors
extended or shortened. Because of the disk Metering
Middle elements
construction there is the possibility to form individual (metering elements) code no.
middle elements (metering elements) with different
Initial element
metering volumes to one complete progressive
distributor.
The different metering volume per piston stroke is
effected by different piston diameters.
A progressive distributor needs at least three
pistons, i.e. at least three middle elements (metering
elements).
Distributor
Technical data outlet
Distributor
Operating pressure-inlet: max. 300 bar inlet
Temperature range: -30 °C to 80 °C
Lubricant: oil- fluid grease - grease Table metering volume:
up to NLGI-cl. 2 Designation Metering volume Code
Revolutions: max. 180 r/min middle (mm³/stroke) no.
element p. outlet p. element
Material: steel, galvanized 075 SX-5 75 150 075
No. of middle elements (metering elements): 117 SX-5 117 234 117
min. 3 middle elements: SX-5 3/6 170 SX-5 170 340 170
max. 10 middle elements: SX-5 10/20 230 SX-5 230 460 230
300 SX-5 300 600 300
Dimensional drawing: 380 SX-5 380 760 380
470 SX-5 470 940 470
34,6 29,6 G 1/4 outlets
19,8 63 6,5
1
7
46
34,5
16,9
G 3/8 inlet
1
Ø 11
state: 09.14EN
Ø 6,4
No. of No. of Dim. “A” Dim. “B”
middle outlets (mm) (mm)
elements (max.)
3 6 138,2 119,9
170 SX-5
300 SX-5
380 SX-5
4 8 167,8 149,5
XXX
XXX
XXX
24
5 10 197,4 179,1
6 12 227,0 208,7
04-1-32-01
7 14 256,6 238,3
8 16 286,2 267,9
max.
6,8 “B” 15,5 9 18 315,8 297,5
10 20 345,4 327,1
1090200390
“A”
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
SX-5
(without piston).
Initial element
Order-no.: 3983A01
Progressive distributors
The progressive distributor’s individual middle the sealing screw, which separates the two sides, is
elements have two outlets. removed and a screw plug with sealing ring is
screwed into the side that has to be closed. The
Sealing screw AF 2 metering volume of the sealed side now comes out of
the other side, i.e. the metering volume at the open
side doubles.
single single
Sealing screw
Screw plug AF 6 removed
with sealing ring
doubled
Combination of outlets
Screw plug with sealing ring for closing outlets:
AF 6
Order-no.:
Screw plug G 1/4: 090090800513
Sealing ring A14x18x1,5: 090760300621
Separating outlets
In order to separate the combined outlets again, the
sealing screw has to be screwed in again.
AF 2
Order-no.:
Sealing screw: 0802000455
04-1-32-03
1090200390
Combination of outlets at several middle Three outlets combined at two middle elements
To connect three outlets at two adjacent middle
elements
elements, the sealing screw of one middle element
Should the total metering volume of the combined
has to be removed and the outlet opposite the
outlets at one middle element be insufficient, at very
distributor bridge has to be closed with a screw plug
Progressive distributors
G 1/4 Sealing ring DIN 7603 16 The metering volumes of the four outlets then come
A14x19x2 - Cu 26 out of the outlet of the distributor bridge.
Hollow screw
without outlet Sealing ring DIN 7603
AF 19 A14x18x1,5 - soft iron
bridge’s outlet.
Distributor bridge
single double with outlet
04-1-32-04
single
1090200390
Distributor bridge without outlet Four outlets combined at two middle elements
With the help of a distributor bridge without outlet Four outlets at two adjacent middle elements can be
three to four outlets at different adjacent middle combined by means of a distributor bridge wihout
elements can be combined. outlet. The sealing screws of both middle elements
have to the removed and one outlet opposite the
Progressive distributors
Order-no. total: 3985980010010 distributor bridge has to be closed with a screw plug
and sealing ring.
Hollow screw 26
without outlet 20 16
AF 19
Screw plug
with sealing ring
29,6
50
Sealing screw
removed
triple
single
state: 09.14EN
20
an assembly plate has to be put under distributors
9
that are not installed with welding plates or an
assembly angle (see drawing). L 30/5/60
300 SX-5
380 SX-5
Connection: M12x1 pluggable
XXX
XXX
XXX
Switch type: PNP NO
Current load: 200 mA
Voltage: 10 - 60 V DC
Temperature range: -40 °C to 85 °C R
22,3
with NS M12x1
170 SX-5 NS right 3983M310N10
left 3983M310N20
230 SX-5 NS right 3983M410N10
left 3983M410N20
300 SX-5 NS right 3983M510N10
left 3983M510N20
04-1-32-06
Order-no.:
Order-no.:: 0800801957
100091865
Subject to alterations! © BEKA 2014 All rights reserved!
BAIER + KÖPPEL
BEKA Nederland GmbH + CO KG Wagenmakerij
B.V. BEETHOVENSTR.11 14 POSTFACH tel.1320 TEL.: +49 9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK 4762 D-91257 PEGNITZ
AV Zevenbergen D-91253 PEGNITZ FAX: +49 9241 729-50
fax. 0168 338 329 E-MAIL: beka@beka-lube.de
www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
SX-5
29,3
Progressive distributors
The indicator pin can only be installed at the middle
AF 12
elements 170 SX-5 to 470 SX-5 on the right or left
side and must be indicated seperately when order.
9
The indicator pin can not be retrofitted.
A retrofit is only possible by exchanging the middle
element.
Table order-no for middle element with indicator pin
with cover:
Middle elem. with Pos. Order-no.
indicator pin
170 SX-5 right 3983M310K10
left 3983M310K20
230 SX-5 right 3983M410K10
left 3983M410K20
300 SX-5 right 3983M510K10
left 3983M510K20
380 SX-5 right 3983M610K10
left 3983M610K20
Threaded pin 470 SX-5 right 3983M710K10
left 3983M710K20
A proximity switch can be retrofit at indicator pin.
Indicator pin installed
right Order-no complete: 4003000N002
Functional description
A pin (2) is fastened at the piston of the middle
element (1). This can be seen in the transparent cap Threaded pin M4x6 DIN 914
(3) at each piston stroke. Order-no.: 0900914002211
1 2 3
The transparente cap (indicator pin cover) of the
indicator pin can be ordered separately. The proximity switch is adjusted at the assembly.
Order-no.: 4003000S003 When retrofit a proximity switch the threaded pin
must be screwed out and the cap of the indicator pin
04-1-32-07
300 SX-5
380 SX-5
XXX
XXX
XXX
04-1-32-08
Connecting rods M8
Order-no.: see table
1090200390
Progressive distributors
delivered already installed into the distributor, then
please indicate this with the type of fitting, the pipe comes out and they have to be separated by a slash
diameter and the series (see table). (/). For distributor bridges, a plus (+) has to be
indicated instead of the slash.
Outlet Designation
G1/4 without fitting
GE06L male stud coupling,
GE08L pipe-Ø 6, 8, 10 or 12,
GE10L series L
GE12L
state: 09.14EN
04-1-32-09
1090200390
Order example
Progressive distributors
Pipe-Ø
Distributor XXX
bridge without 380 SX-5*
outlet
Screw
Proximity switch plug XXX
300 SX-5*
(Cable see “accessory
progressive distributor”)
XXX
170 SX-5
Assembly plate
must be ordered
separately
(see “elements with
proximity switch L R
Connection
Inlet fitting position
L = left
R = right
No. of outlets
Inlet fitting
Outlet fitting
Connection position
Metering code no. at outlets
04-1-32-10
1090200390
Progressive distributors
controls the pipe lines from the distributor outlet to
the lubrication point for demolition or break.
4 monitored
lube points
Connection cable
distributor to distributor
brown 80 80
80
Pressure makeup
black Pressure makeup valve valve in lube point
Function in lube point Progressive distributor
A line break element with pressure indication is Pressure indicator
screwed at the lube point of the distributor outlet that pin is visible = OK
pin is invisible = line break
has to be monitored. The element is screwed
together with flanges and plates (see next page) by Line break element
means of cylinder screws and hexagon socket transparent
cap
screws.
A pressure makeup valve with non-return valve with transparent
an opening pressure of 75 bar is screwed directly cap
into the lube point. With this pressure, that always Pressure
exists within the line, the actuation piston presses a indication
pin
button via the actuation lever in the element. Hence
Circuit
the electrical circuit is closed and the pin of the board
pressure indication is visible. Button
state: 09.14EN
Outlet
G 1/4
ca. 128
78,5
54,5
34,5
Technical data
Operating pressure inlet: max. 300 bar
Operating voltage: 10 - 55 V DC
Contact capacity: 50 mA DC
Connection: Round connector M12,
state: 09.14EN
Pin 1 = +Ub
Pin 4 = outlet (NO contact),
contact opens in case of fault
04-1-32-12
1090200390
Individual components of
9
line break monitoring 8
6
Line break 5
Progressive distributors
monitoring
10
2
Thread
lube point 9
8
1
Progressive 4 7
distributor SX-5
10
2 2 12
Thread
lube point
7
2 Thread
8 11 lube point
9
1 8
9
3
Table of order numbers of individual components of Order number table for connecting rod (Pos. 7) for
line break monitoring for SX-5 (see figure above): SX-5 (1 pcs):
Position Designation Order-no.
1 Inlet flange, 437501010100 Number of line
plug M12x1 break elements Connect. Order-no.
2 Line break element 437502010100 or intermediate rod
3 Final plate 4375060100 plates
4 Intermediate plate 4375040200 1 M4 x 85 F4375/21-01 002
5 Connection cable 1000913864 2 M4 x 115 F4375/21-01 004
6 Outlet flange, 437503010100 3 M4 x 144,5 F4375/21-01 006
bushing M12x1 4 M4 x 174 F4375/21-01 008
state: 09.14EN
Ø6
Press. makeup Thread Order-no. Straight makeup
G
valve G valve
straight M8x1k 43750706A111
Progressive distributors
Ø6
M8x1k 43750706B111
M10x1k 43750706B211 Elbow
7,5
makeup
30
swivelling M10x1k 43750706B311
valve
makeup valve (long)
(Pos. 11*) R 1/8”k 43750706B411 G
R 1/4”k 43750706B511
ca. 57
1/8-27NPT 43750706B611
Ø6
elbow M8x1 43750706C111
Swivelling
5,5
makeup valve M10x1 43750706C211
26,5
makeup
(Pos. 12*) G 1/8 43750706C311 valve
* see individual compontents of line break monitoring G
Screw
plug
Code
number
380
300*
Inlet
470 flange
plug
M12x1
L R
Proximity switch Outlet
(see „Accessory Outlets Connection flange
progressive distributors“ position bush
state: 09.14EN
G 1/4
for cable) Inlet fitting plug M12x1
Assembly plate must be ordered separately L = left
(see documentation R = right
SX-5 “elements with proximity switch”)
* = Sealing screw removed
Inlet fitting
Outlet fitting
Connection position
1090200390
Progressive distributors
extended or shortened. Because of the disk
construction there is the possibility to form individual
middle elements (metering elements) with different End element
metering volumes to one complete progressive Metering
code no.
distributor.
61,5
min. 3 middle elements: UX 3/6
38,7
1,5
UX 2000
UX 1500
100
52
38
p. outlet p. element
UX 1000 1130 2260 1000
UX 1500 1540 3080 1500
UX 2000 2000 4000 2000 15 “B”
state: 09.14EN
“A”
7 14 270 240
8 16 300 270
9 18 330 300
1090200390
10 20 360 330
© BEKA 2014 All rights reserved! Subject to alterations!
BAIER + KÖPPEL GmbH + CO
BEKA KG BEETHOVENSTR.
Nederland B.V. 14 Wagenmakerij
POSTFACH 111320 TEL.: +49
tel.9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK D-91257 PEGNITZ 4762D-91253 PEGNITZ
AV Zevenbergen FAX: +49fax.
9241 729-50
0168 E-MAIL: beka@beka-lube.de
338 329 www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
UX
(without piston).
As standard, all elements are delivered without
fittings at the distributor inlet and at the outlet. The
connection thread at the distributor inlet (initial
element) is G 1/2 and at the distributor outlets
(middle elements) G 3/8.
Initial element
Order-no.: 4005 97 0000
All pipe fittings with a suitable connection thread and
a suitable nominal pressure can be screwed into the
initial element’s distributor inlet as well as the middle
elements’ distributor outlets (see “Accessory
progressive distributor”, respectively “Fittings and
accessories”).
1090200390
Progressive distributors
progressive distributor. bridge. When necessary, we can drill the outlets in
To this purpose, two outlets of one middle element vertical direction. This cannot be changed any more.
are connected with a distributor bridge with outlet.
The metering volumes of both outlets then come out Two outlets combined at adjacent middle
of the distributor bridge’s outlet. elements
Of two neighboring middle elements, one outlet each
Distributor bridge Distributor is connected via a connection hole. Only BEKA may
with outlet outlets drill this hole. One of the two outlets has to be locked
with a screw plug and a sealing ring.
83
AF 22
38 31 Distributor Outlets combined
2
3 inlet by a bore
32,7
26
13
4
G 3/8
1,8
G 3/8 1
8,3
state: 09.14EN
consisting of:
Pos. 1 1 Bridge strip,
Order-no.: F0414/07-00
Pos. 2 2 Hollow screws without outlet,
Order-no.: 04033331306
Pos. 3 2 Sealing rings A18x24x1,5
04-1-40-03
Screw plug and sealing ring for locking outlets Four outlets combined at adjacent middle
Order-no.: elements
Screw plug G 3/8: 090090800713 Two outlets of a middle element are combined with a
Sealing ring A17x21x1,5: 090760301711 distributor bridge with outlet. Both outlets of the
neighbored middle element are connected with the
Progressive distributors
AF 8
The combined outlets of the neighbored middle
element have to be locked by a screw plug and a
sealing ring.
Note: Outlets must not be locked without redirecting
the lubricant to another outlet as otherwise the For combining the outlets at neighbored middle
distributor blocks! elements later, the concerned middle element has to
be replaced by one with a hole.
Three outlets combined at adjacent middle
elements The metering volumes of the four connected outlets
Two outlets of a middle element are combined with a come out of the distributor bridge’s outlet.
distributor bridge with outlet. The adjacent middle
element’s third outlet is connected with an outlet of
the first middle element via a connection hole. Only
BEKA may drill the connection hole. Distributor bridge Screw plugs with
with outlet sealing rings
Middle elements
Distributor
04-1-40-04
Progressive distributors
Three different types of proximity switches are
available (see table). Without further indication, the
proximity switch M12x1 is installed on the right side
of the last element as standard. An assembly on the
left side or of another proximity switch has to be
indicated separately.
1 BN BN brown
2 1 +
4 BK BK black
2 1
3 BL BL blue 3
3 4 -
At the M12x1 (see section) model,
the pin (2) is led outside via a seal.
At the model M18x1 / M30x1,5 the
pin works leakage free in the
medium.
Dimensions for proximity switch M12x1: Table of order-no. for middle element with proximity
switch M18x1 (special model):
23,5
Middle element Pos. Order-no.
15 20,5 with NS M18x1
plug
Progressive distributors
45
UX 2000 N18/24 R right 4005982005
UX 2000
13 UX 2000 N18/24 L left 4005982007
35,5
UX 1000
L R
L = left inlet
R = right
Installation dimensions for a proximity switch Table of order-no. for middle element with proximity
M30x1,5: switch M12x1 (standard):
UX 1500
UX 2000 N12/24 L left 4005982004
46
UX 2000
43
UX 1000
54,3
L R
inlet
L = left
R = right
Installation dimensions for a proximity switch M18x1: Table of order-no. for a metering element with
proximity switch M30x1,5 (special model):
23,5 Middle element Pos. Order-no.
44,3 with NS M30x1,5
35 plug
M12x1 UX 1000 N30/24 R right 4005981008
UX 1000 N30/24 L left 4005981009
state: 09.14EN
UX 1500
UX 2000 N30/24 L left 4005982009
46
UX 2000
53
UX 1000
64,3
04-1-40-06
L R
inlet
L = left
1090200390
R = right
Subject to alterations! © BEKA 2014 All rights reserved!
BAIER + KÖPPEL
BEKA Nederland GmbH + CO KG Wagenmakerij
B.V. BEETHOVENSTR.11 14 POSTFACH tel.1320 TEL.: +49 9241 729-0
0168 371 538 WEB: www.beka-lube.de
info@beka.nl
PRÄZISIONSAPPARATEFABRIK 4762 D-91257 PEGNITZ
AV Zevenbergen D-91253 PEGNITZ FAX: +49 9241 729-50
fax. 0168 338 329 E-MAIL: beka@beka-lube.de
www.beka.nl
Progressive Central Lubrication Systems
Progressive distributors
UX
Progressive distributors
The indicator pin cannot be attached later.
Retrofitting an indicator pin is only possible by
22
replacing a middle element.
AF 24
Indicator pin
installed at the right
Functional description:
At the indicator pin, the pin (1) is directly connected
to the piston (2) of the progressive distributor. With
every stroke, the pin (1) is compulsory pushed out or
drawn back.
state: 09.14EN
1
04-1-40-07
2
1090200390
Connecting rods M7 - St
see table
UX 2000
UX 1500
UX 1500
Progressive distributors
already installed into the distributor, they have to be
marked with the diameter and the series (see table): and have to be separated with a slash (/). The
outlets’ union in vertical direction has to be indicated
Inlet Designation
with a plus (+) instead of the slash.
G1/2 without fitting
GE08L male stud coupling
GE10L pipe-Ø 8, 10, 12 or 15, The metering code numbers of combined outlets
GE12L series L accumulate (see “Combination of outlets”).
GE15L
Screw plugs and outlets that are closed with
The fittings can also be ordered separately (see distributor bridges are marked with a line (--).
“Accessory progressive distributor” or “Fittings and
accessories”). Proximity switch
Three different types of proximity switches are
When there is no indication concerning the fittings, available:
delivery is without fitting as standard!
NS Designation
Distributor outlet N12/24 proximity switch M12x1 (standard)
The fitting type at the distributor outlets has to be N18/24 proximity switch M18x1
indicated with the diameter and the series, when the N30/24 proximity switch M30x1,5
order is placed (see table):
For other proximity switches, the thread diameter of
Outlets Designation the proximity switch has to be indicated after the
G3/8 without fitting code letter N and then after the slash (/), the
GE06L male stud coupling, proximity switch’s voltage.
GE08L pipe-Ø 6, 8, 10 or 12,
GE10L series L
The installation position has to be indicated after the
GE12L
WS12L elbow swivelling screw fitting, metering code number of the metering element, to
WS10S pipe-Ø 10 oder 12, series L or S which the proximity switch shall be attached, with NS
RGE06L non-return valve, on the left or on the right side as requested.
RGE08L pipe-Ø 6, 8, 10 or 12, R = right
RGE10L series L L = left
RGE12L
When no installation position is indicated, the
Note: proximity switch is assembled on the right side of the
Without an indication of the series, a straight last element as standard.
fitting, respectively a non-return valve of the
state: 09.14EN
Order example
Proximity switch
(see cable
under
Progressive distributors
“Accessory
progressive
distributor”
UX 1500
Outlets
G 3/8 Outlet closed
with screw plug
UX 1000
(see “Combination
of outlets)
UX 2000
Distributor bridge
UX 1000 with outlet
G 3/8
L R
Inlet
G 1/2
1090200390