Sie sind auf Seite 1von 4

HP ProLiant DL380 G5 Server - Configuring

System Board

In this document:
System Board Components
System Maintenance Switch
NMI Jumper
Systems Insight Display LEDs and Internal Health LED Combinations

System Board Components


Figure 1: System Board Components:

Item Description Item Description


1 Fan board connector 11 System battery
2 PPM 1 12 PCI riser cage connector
3 PPM 2 13 Fan 4 connector
4 Power supply backplane connector 14 Fan 2 connector
5 PCIe slot 1 15 Fan 3 connector
6 PCIe slot 2 16 Fan 1 connector
7 NMI jumper 17 FBDIMM slots (1-8)
8 iLO 2 diagnostic LEDs 18 Multibay interface connector
9 System maintenance switch 19 Processor socket 1
Item Description Item Description
10 Internal USB connector* 20 Processor socket 2

* The lower USB connector is unavailable.

System Maintenance Switch

Position Default Function


Off = iLO 2 security is enabled.
S1 Off
On = iLO 2 security is disabled.
Off = System configuration can be modified.
S2 Off
On = System configuration is locked and cannot be
modified.
S3 Off Reserved
S4 Off Reserved
Off = Power-on password is enabled.
S5 Off
On = Power-on password is disabled.
Off = Normal
S6 Off
On = ROM treats system configuration as invalid.
S7 Off Reserved
S8 Off Reserved

When the system maintenance switch position 6 is set to the On position, the system is prepared
to erase all system configuration settings from both CMOS and NVRAM.

CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to


properly configure the server or data loss could occur.

NMI Jumper
The NMI jumper allows administrators to perform a memory dump before performing a hard reset.
Crash dump analysis is an essential part of eliminating reliability problems, such as hangs or
crashes in OSs, device drivers, and applications. Many crashes can freeze a system, requiring a
hard reset. Resetting the system erases any information that would support root cause analysis.

Systems running Microsoft Windows experience a blue-screen trap when the OS crashes. When
this happens, Microsoft recommends that system administrators perform an NMI event by
temporarily shorting the NMI header with a jumper. The NMI event enables a hung system to
become responsive again.
Systems Insight Display LEDs and Internal Health LED
Combinations
When the internal health LED on the front panel illuminates either amber or red, the server is
experiencing a health event. Combinations of illuminated system LEDs and the internal health
LED indicate system status.

Internal
Systems Insight
health LED Status
Display LED and color
color
One or more of the following
conditions may exist:

• Processor in socket X has


failed.

• Processor X is not installed in


Red the socket.
Processor failure, socket X
(amber)
• Processor X is unsupported.

• ROM detects a failed processor


during POST

Processor in socket X is in a pre-


Amber
failure condition.
One or more of the following
conditions may exist:

• PPM in slot X has failed.


PPM failure, slot X
Red
(amber)
• PPM is not installed in slot X,
but the corresponding
processor is installed.

Red FBDIMM in slot X has failed.


FBDIMM failure, slot X
(amber) FBDIMM in slot X is in a pre-failure
Amber
condition.
FBDIMM failure, all slots in No valid or usable memory in
Red
one bank (amber) specified bank.
Online spare memory Bank X failed over to the online
Amber
(amber) spare memory bank.
Online spare memory Invalid online spare memory
Red
(flashing amber) configuration.
Online spare memory Online spare memory enabled and
Green
(green) not failed.
Internal
Systems Insight
health LED Status
Display LED and color
color
Bank(s) X failed over to the
Mirrored memory (amber) Amber
mirrored memory bank(s).
Mirrored memory (flashing Invalid mirrored memory
Red
amber) configuration.
Mirrored memory enabled and not
Mirrored memory (green) Green
failed.
The Health Driver has detected a
Amber
cautionary temperature level.
Overtemperature (amber)
The server has detected a
Red hardware critical temperature
level.
Riser interlock (amber) Red PCI riser cage is not seated.
Amber One fan is failed or removed.
Fan (amber)
Two or more fans have failed or
Red
are removed.
© 2003 Hewlett-Packard Company ·

Das könnte Ihnen auch gefallen