Sie sind auf Seite 1von 6

TEST REPORT

REPORT NO. JKTR18000534

Applicant : PT. LIGNO SPECIALTY ADHESIVE Date : Apr 23, 2018


Kawasan Industri Km. 7, Jl. Karet IV No. 37
Desa Mekarjaya, Kec. Sepatan
Tangerang - Banten

Attn : Hermen

Sample description:
One (1) bottle of submitted sample said to be :

Material Name : WATER BASE WHITE FORTEBOND LIGNO ADHESIVE


Series No. : LA 100 Series, LA 200 Series, LA 300 Series, LA 400 Series, LA 500 Series, LA
600 Series, LA 700 Series, LA 800 Series, LA 900 Series, PG 6034 H, PG 6060
Series, PG 6064 A, PG 6225 Series, PG 6233 Series, PG 6239 NFB, PG 6240 UN,
PG 6250 Series, PG 6262 Series, PG 6263 LS, PG 6280, PG 6282 Series, PG
6299 L, PG 6315, PG 6331 Series, PG 6351, PG 6430 Series, PG 6433 N, PG
6434 FB, PG 6515 B, PG 6606, PG 6743, PG 6800 Series, PG 6801, PG 6802
Series, PG 6804 Series, PG 6815 A, PG 6820, PG 6840, PG 6850 Series, PG 6856
Series, PG 6900, PG 9801 P-01, KR Series, Super 800, Super 900, WG 3479, WG
9017, WG 9135 Series, WG 9141, WG 9151 Series, WG 9153 L, WG 9160 Series,
WG 9236 HV, WG 9241HV, WG 9248 Series, WG 9342 Series, WG 9454, WG
9801 Series, WG 9807 Series, WG 9808 SJ, WG 9809, WG 9861 P, NSS Clear
Glue, NSS White Glue.
Country of Original : Indonesia
Buyers Company Name : PT. Kgeo Electronics Indonesia, PT. Emsonic Indonesia, PT. Triwall Indonesia, dll
Date sample received : Apr 16, 2018
Testing period : Apr 16, 2018 to Apr 23, 2018

**************************************************************************************************************************
Test conducted:
As requested by the applicant, for details please refer to attached pages.
Type of test: RoHS wet chemical analysis.
**************************************************************************************************************************

IUS – CR.RH – 001 Page 1 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com
TEST REPORT
REPORT NO. JKTR18000534
FN

Prepared and checked by:


For Intertek Indonesia

Made Widyani
Operation Manager - Testing
(THIS REPORT SHALL NOT BE REPRODUCED WHOLLY OR IN PARTS WITHOUT WRITTEN APPROVAL FROM THE LABORATORY)

IUS – CR.RH – 001 Page 2 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com
TEST REPORT
REPORT NO. JKTR18000534

Test conducted:

Test Result Summary:


Result Standard
Test Item Unit Test Method RL
Liquid Adhesive Limit #
Heavy Metal
With reference to IEC 62321:
2013, by microwave or acid
Cadmium (Cd) content ppm ND 5 100
digestion and determined by ICP-
OES.
With reference to IEC 62321:
2013, by microwave or acid
Lead (Pb) content ppm ND 5 1000
digestion and determined by ICP-
OES.
With reference to IEC 62321:
2013, by microwave or acid
Mercury (Hg) content ppm ND 5 1000
digestion and determined by ICP-
OES.
With reference to IEC 62321 :
2008, by alkaline digestion and
Chromium VI (Cr6+) content ppm ND 1 1000
determined by UV-VIS
spectrophotometer
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls
ppm ND 5 1000
(MonoBB)
Dibrominated Biphenyls
ppm ND 5 1000
(DiBB)
Tribrominated Biphenyls
ppm ND 5 1000
(TriBB)
Tetrabrominated Biphenyls
ppm ND 5 1000
(TetraBB)
With reference to IEC 62321:
Pentabrominated Biphenyls
ppm 2015, by solvent extraction and ND 5 1000
(PentaBB)
determined by GC-MS and
Hexabrominated Biphenyls
ppm further HPLC-DAD confirmation ND 5 1000
(HexaBB)
when necessary.
Heptabrominated Biphenyls
ppm ND 5 1000
(HeptaBB)
Octabrominated Biphenyls
ppm ND 5 1000
(OctaBB)
Nonabrominated Biphenyls
ppm ND 5 1000
(NonaBB)
Decabrominated Biphenyl
ppm ND 5 1000
(DecaBB)

IUS – CR.RH – 001 Page 3 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com
TEST REPORT
REPORT NO. JKTR18000534

Test conducted:

Test Result Summary:


Result Standard
Test Item Unit Test Method RL
Liquid Adhesive Limit #
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl ppm ND 5 1000
Ethers (MonoBDE)
Dibrominated Diphenyl
Ethers (DiBDE) ppm ND 5 1000
Tribrominated Diphenyl
Ethers (TriBDE) ppm ND 5 1000
Tetrabrominated Diphenyl ppm ND 5 1000
Ethers (TetraBDE)
Pentabrominated Diphenyl With reference to IEC 62321:
ppm 2015, by solvent extraction and ND 5 1000
Ethers (PentaBDE)
determined by GC-MS and
Hexabrominated Diphenyl
ppm further HPLC-DAD confirmation ND 5 1000
Ethers (HexaBDE) when necessary.
Heptabrominated Diphenyl
ppm ND 5 1000
Ethers (HeptaBDE)
Octabrominated Diphenyl
Ethers (OctaBDE) ppm ND 5 1000
Nonabrominated Diphenyl
Ethers (NonaBDE) ppm ND 5 1000
Decabrominated Diphenyl ppm ND 5 1000
Ether (DecaBDE)
Phthalate test :
Di(2-ethylhexyl) Phthalate ppm ND 50 1000
(DEHP) With reference to IEC 62321-8 :
Benzyl Butyl Phthalate
ppm 2016, by solvent extraction and ND 50 1000
(BBP) determined by GC-MS.
Dibutyl Phthalate (DBP) ppm ND 50 1000
Diisobutyl Phthalate (DIBP) ppm ND 50 1000

Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
RL = Reporting limit, quantitation limit of analyte in sample
# = Refer to 2011/65/EU for homogeneous material.

IUS – CR.RH – 001 Page 4 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com
TEST REPORT
REPORT NO. JKTR18000534

Test conducted:

Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) content and PBB/PBDE


Reference Standard : Cd/Pb : IEC 62321-5: 2013; Hg: IEC 62321-4:2013;
Chromium (VI): IEC 62321-7-1:2015 (boiling water extraction)
Chromium (VI): IEC 62321:2008 (alkaline extraction)
PBBs/PBDEs: IEC 62321: 2015
Sampling

Cd/Pb/Hg Cr6+ Polymers / PBBs/PBDEs


Metal Electronics

For different material, Weigh sample and add


digest the sample with 50cm2 sample, boiling Weigh sample, organic solvent
appropriate acid*1 water extraction alkaline extraction

By Soxhlet extraction or
Confirm the tested Solvent extraction
samples are totally
dissolved
Cool and filter the extract
Concentrate the extract and
make up with organic
solvent
Make up with
deionized water Make up with deionized water and add
diphenyl-carbonized solution
Analyzed by GC-MS

Analyzed by ICP-OES
Metal Polyester/
Electronics
Visual observation *2

Remarks: Analyzed by UV-VIS


*1: List of Appropriate Acid:
Material Acid Added for Digestion
Polymers HNO3,HCl,HF,H2O2,H3BO3
Metals HNO3,HCl,HF
Electronics HNO3,HCl,H2O2,HBF4
*2: If sample solution is significantly more intense than 0.13 µg/cm² equivalent comparison standard, Chromium VI would
be determined as detected, the result of visual observation is positive.

IUS – CR.RH – 001 Page 5 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com
TEST REPORT
REPORT NO. JKTR18000534

Test conducted:

Measurement Flowchart:

Test for Phthalates Contents


Reference Method: IEC 62321-8 : 2016

Sampling

Weigh sample and add organic solvent

By solvent extraction

Concentrate the extract and make up with


organic solvent

Analyzed by GC-MS

## END OF THE TEST REPORT ##


This report (including any enclosures and attachments) are prepared for the exclusive use of the Customer(s) named in the report and solely for the purpose for
whichit is provided and on the basis of instructions and information and/or materials supplied by Intertek’s Customer. The test results relate only to the specific items
tested and are not intended to be a recommendation for any particular course of action. Customer is responsible for acting as it sees fit on the basis of such results.
Unless Intertek provide express prior written consent, no part of this report should be reproduced, distributed or communicated to any third party. Intertek do not
accept any liability if this report is used for an alternative purpose from which it is intended, nor do Intertek owe any duty of care to any third party in respect of this
report. Except where explicitly agreed in writing, all work and services performed is governed by Intertek Standard Terms and Conditions of Service which is available
on request or can be obtained at http://www.intertek.com/terms

IUS – CR.RH – 001 Page 6 of 6

PT. Intertek Utama Services Citrabuana Indoloka Building Telp. (62-21) 391 8584 (Hunting), 391 8574 (Direct), Fax. (62-21) 391 8345
Jl. Cikini IV No.2, Gondangdia Hardline Laboratory:Jakarta (62-21) 391 6611, Semarang (62-24) 762 7107 /
Jakarta 10330, Indonesia 762 7325
Email : hlcoordinator.indonesia@intertek.com Website: www.intertek.com

Das könnte Ihnen auch gefallen