STARTER V4.

5 SP1
SIEMENS

General conditions and function limitations, notes for configuration and operation

These notes take precedence over statements contained in other documents.


Because these notes contain important information for the installation and use of the software, please read them carefully.

STARTER V4.5 SP1


ARTS-Plus Brief Description Circumstances Possible work-around Affected DO Drive Family new since
RQ

PB_PN_Commu_SINAMICS

S120 CU310-2 Cranes


DCC SINAMICS

ET200Pro FC-2

S120-ACDrive
DC Master

STARTER
ET200Pro

SCOUT
GM150
GH150

SM120

SM150
G120P

GL150

SL150
G120

G130

G150

S110

S120

S150
DCP
DCC-Editor_SINAMICS - DCC
AP01129806 After converting and If a created project is converted to a higher STARTER version, In the event of an error, note the X X X - - - - X X X X X - X X X X X - X X X X V2.1
reconverting the project, the project then compiled with "Save and recompile all" and names of the DCC charts that cannot
problems occur in SINAMICS then reconverted again to the original STARTER version via be read and delete these
in conjunction with DCC charts "Save in old project format", SINAMICS inconsistency is subsequently. Then replace the noted
when uploading to the PG. displayed after connection to the target device. No errors occur names with the names of the readable
when loading to the PG, but a further DCC chart is added for DCC charts and recompile. A
each DCC chart below the DO. The DCC chart can be read. download should then be performed.
AP01294745 Installation of an installable As of STARTER V4.2, installable libraries can be created from Create a new installable library with X X - - - X X X X - X X - - X - - X X - X X X V4.5
library created with STARTER DCC libraries that can be installed irrespective of the STEP 7 STARTER V4.3, V4.4, or V4.5 from
V4.2 is aborted with an error project. In STARTER V4.3, V4.4, V4.5, the installation of an the original project or use a library
message. installable library created with STARTER V4.2 is aborted with exported from STARTER V4.2 in xml
an error message. The library is visible after a certain time, but format.
cannot be used for all device types.
STARTER - General
AP00317285 A parallel online operation with The simultaneous connection of two or more computers or --- - - - - - - - X X - X X - - X - - X - X - - - V3.1
several PCs and STARTER is tools (AOP, STARTER) with a single drive device is not
not permitted. prevented. This, however, can cause problems. Consequently,
a parallel online operation with multiple PCs and STARTER is
not permitted.
AP00326235 Access level BOP and Starter Access level BOP and Starter are coupled in the p0003 None - - - - - - - X X - X X - - X - - X - - - X - V3.2
are coupled in the p0003 parameter. There is no separate setting option.
parameter. There is no
separate setting option.
AP00457315 Consistency for shutdown of If the 24 V power supply is switched off for a component, The consistency display will be - - - - - - - X X - X X - - X - - X - X - - - V4.1
the 24 V power supply. although the drive shows an error message, the STARTER updated automatically after going
remains consistent. offline or online.
AP01089398 Opening projects that have Opening projects that have been created in STEP 7 incl. Drive Install the missing option packages. - - - - - - - - - - - - - - - - - - - - - - X V4.2
been created in STEP 7 incl. ES results in errors in STARTER stand-alone. Projects that have been created in
Drive ES results in errors in higher-order engineering environments
STARTER stand-alone. can only be processed further in these
environments.
AP01404727 When saving data to the When saving data to the memory card, an error message is This error message can be ignored as - - - X X - - - - - - - - - - - - - - - - - X V4.3 SP2
memory card, an error output although the data has been written. the data has been written to the
message is output although memory card.
the data has been written.

STARTER_V4.5_SP1_Restrictions -1- 18.07.2016


STARTER V4.5 SP1
SIEMENS

ARTS-Plus Brief Description Circumstances Possible work-around Affected DO Drive Family new since
RQ

PB_PN_Commu_SINAMICS

S120 CU310-2 Cranes


DCC SINAMICS

ET200Pro FC-2

S120-ACDrive
DC Master

STARTER
ET200Pro

SCOUT
GM150
GH150

SM120

SM150
G120P

GL150

SL150
G120

G130

G150

S110

S120

S150
DCP
STARTER - Drive wizard
AP01465665 Under certain circumstances, Without the horizontal scrollbar, you cannot view all information If this problem occurs, it can be solved X - - - - - - - - - - - - - - - - - - - - - X V4.3 SP2
the horizontal scrollbar may be in the mask. by restarting the wizards.
missing in the wizard screen
“Drive- Additional data”.
TFS331173 Configuration/selection of 1PH8 motors with brake are not offered for selection in the You must always select the same - - - - - - - - - - - - - - - - - - - - - - X V4.4
1PH8 motors with brake Starter drive wizard. motor without brake (8th digit of the
MLFB): On induction motors with
MLFB 1PH8xxx-3xxx, you must select
1PH8xxx-1xxx. On induction motors
with MLFB 1PH8xxx-4xxx, you must
select 1PH8xxx-2xxx. Further, you
must manually adjust the following
parameters via the expert list: -
Permissible maximum motor speed
with existing holding brake (p1082) -
engagement and disengagement
times of the holding brake (p1216,
p1217) - consider the moment of
inertia of the holding brake
(additionally to p341 or p1498). The
corresponding values are stored for
the specific types in the Configuration
Manual for 1PH8 motors (Chapter
holding brakes). Note: If the brake
moment of inertia shall be considered
via p341, the motor must be
subsequently registered as p300 = 1
("induction motor (rotary))".
TFS436612 FM "Spindle diagnostics": With the selection of the function module "Spindle diagnostics" First select the "Spindle diagnostics" Servo - - - - - - - - - - - - - - - - - - - - - - X V4.5
p322 = 0 is set on activation the maximum motor speed p322 = 0 is set. For listed motors function module and then start the
this value cannot be changed manually due to write protection. drive wizard. Then p322 represents
the actual maximum motor speed
value.
STARTER - DCC
TFS470388 Published DCC parameters After loading to the PG or a change of the BICO Close the expert list and reopen it. - X - - - - - - - - - - - - - - - - - - - - X V4.5
are no longer displayed in the interconnection at the published DCC parameters is carried out
expert list. with the expert list open, the published DCC parameters are no
longer displayed in the expert list.
STARTER - Unit switchover
AP00422169 Incorrect display of the units in After changing the units in the expert list (online), the display in The units must be changed offline. A - - - - - - - - - - - - - - - - - - - - - - X V4.1
STARTER the "Units" column is not updated download must then be performed.
AP00429757 Unit switchover (SINAMICS) The unit system cannot be changed via the expert list, neither The unit system can be changed - - - - - - - X X - X X - - X - - X - X - - - V4.1
via the expert list. offline nor online. offline for every drive object on the
Configuration -> Units page.
STARTER - General communication
AP01423965 Telegrams 700 (SIC) and 701 Telegrams 700 (SIC) and 701 (SIC) cannot be configured in Use PROFIBUS GSD or PROFINET - - - - - - - - - - - - X - - - - - - - - - X V4.3 SP2
(SIC) cannot be configured in the HW Config via SlaveOM and DeviceOM. GSD.
the HW Config via SlaveOM
and DeviceOM.

STARTER_V4.5_SP1_Restrictions -2- 18.07.2016


STARTER V4.5 SP1
SIEMENS

ARTS-Plus Brief Description Circumstances Possible work-around Affected DO Drive Family new since
RQ

PB_PN_Commu_SINAMICS

S120 CU310-2 Cranes


DCC SINAMICS

ET200Pro FC-2

S120-ACDrive
DC Master

STARTER
ET200Pro

SCOUT
GM150
GH150

SM120

SM150
G120P

GL150

SL150
G120

G130

G150

S110

S120

S150
DCP
STARTER - USB communication
AP01284217 No active node in accessible After disconnecting and connecting USB-capable devices In the "Device Manager / Universal - - - - - X - - - - - - - - - - - - X - - - X V4.3 SP1
nodes via USB several times, it can happen that no node is detected. Serial Bus Controllers", deactivate the
appropriate "USB Enhanced Host
Controller" and then activate it shortly
afterwards, or restart the PC.
AP01290822 With a G120 of version V4.4, If the G120 is connected via USB and a comparison is initiated, The G120 must then be restarted - - - - - X - - - - - - - - - - - - - - - - - V4.3 SP1
the USB connection may hang the connection may be terminated. It may then no longer be (Power off/on) in order to go online
up during a comparison. possible to go online with the G120 via USB. again.
AP01455984 It is not possible to go online No nodes are found with Accessible nodes if the device is Do not use a USB hub, connect the - - - - - X - - - - - - - - - - - - X - - - X V4.3 SP2
via a USB hub. connected via a USB hub. device directly.
STARTER - Safety Integrated
AP01228678 With a CUA31 HW version C With a CUA31 HW version C or less, safety functions of the Use a CUA31 with a HW version - - - - - - - - - - - - - - X - - - - - - - - V4.3
or less, safety functions of the V4.5 firmware can be configured in STARTER, but not used. greater than C.
V4.5 firmware can be
configured in STARTER, but
not used.
STARTER - Data set changeover
AP01233964 Drive data sets (DDS) are not Drive data sets (DDS) can be activated online via P180, but Change parameter P180 and then load X - - - - X - X X - X X - - X - X X - X X - X V4.3
displayed if they are activated they are not displayed in the screen forms or in the expert list. the project to the PG. This updates the
online via P180. "Online view" and the indices of the
If DDS >1 is activated in the device (via P180=3), then the drive data sets are displayed.
indices are not displayed in the expert list for DDS parameters
in STARTER.
STARTER - Download
AP01360252 During a download, During a download, supplementary data (user data) is not None - X - - - - - X X - - - - - X - - X - - - - X V4.3 SP1
supplementary data (user loaded to the target system. This also applies to the storage of HF2
data) is not loaded to the data on the CompactFlash card. This data is therefore not
target system. This also stored on the CompactFlash card and is not displayed in
applies to the storage of data STARTER (e.g. in the Comparison dialog box).
on the CompactFlash card.
AP01374022 During a download, During a download, supplementary data (user data) is not None - - - - - - - - - - - - - - - - - - - - - - X V4.3 SP2
supplementary data (user loaded to the target system. Accordingly, the supplementary
data) is not loaded to the data is also not displayed in STARTER (e.g. in the Comparison
target system. dialog box).
STARTER - STEP 7 integration
TFS40695 No prompt that the program If an S120 configured on the PROFINET IO system is deleted None - - - - - - - X X - X X - - X - - X X X - X X V4.3 SP2
under the drive will be deleted. in the HW Config via DeviceOM, there is no prompt whether
the associated program should also be deleted. The program
can therefore be lost.
STARTER - Know-how protection
TFS498347 Know-how protection and The know-how protection function can be set with STARTER Urgent recommendation: Do not X - - - - - - - - - - - - - - - - - - - - - X V4.5 SP1
SINAMICS DCM cannot be for this type of device. However, know-how protection cannot activate know-how protection for this
used be deactivated using STARTER. Also occurs with STARTER type of device. Note: With Starter V4.4
V4.4 SP1. know-how protection can be activated
and deactivated.

STARTER_V4.5_SP1_Restrictions -3- 18.07.2016


STARTER V4.5 SP1
SIEMENS

ARTS-Plus Brief Description Circumstances Possible work-around Affected DO Drive Family new since
RQ

PB_PN_Commu_SINAMICS

S120 CU310-2 Cranes


DCC SINAMICS

ET200Pro FC-2

S120-ACDrive
DC Master

STARTER
ET200Pro

SCOUT
GM150
GH150

SM120

SM150
G120P

GL150

SL150
G120

G130

G150

S110

S120

S150
DCP
STARTER - Closed-loop control
AP00455745 Automatic controller STARTER up to V4.1.2: The automatic controller setting for If the automatic controller setting does Servo - - - - - - - - - - - - - - X - - X - - - - - V4.1
optimization for servo. servo has not been released. not provide satisfactory results, a
manual setting of the controllers and
STARTER as of V4.1.2: The automatic controller setting for filters can be made.
servo may not provide the best possible settings in all cases.
This applies especially to the placing of bandstop filters.
STARTER - Upgrade
AP01133383 After converting a project After converting a project created with SIMOTION SCOUT, it The message windows which open - - - - - - - - - - - - - - - - - - X - - - X V4.2
created with SIMOTION may be that STARTER can no longer be operated. During after the conversion are not visible.
SCOUT, it may be that conversion, STEP 7 messages are output in the background They must be brought to the
STARTER can no longer be that the user does not see. foreground with ALT +TAB. STARTER
operated. can only be operated after these
messages have been acknowledged.
STARTER - Axis control panel
TFS496087 Incorrect enable display on the When calling the control panel, it is possible for the status of For the control panel the display jumps - - - - - - - - - - - - - - - - - - - - - - X V4.5 SP1
control panel the enables to be displayed incorrectly. to the correct values via "Assume
control priority" or by changing an
enable. The "Control/status words"
display should always be selected to
display the status of the enables, and
not the control panel.
STARTER_OH - Print
AP01022389 When printing out entire When printing out entire chapters with sections in the help, the Only print individual topics and avoid - - - - - - - - - - - - - - - - - - X - - - X V4.2
chapters with sections in the STARTER cannot be operated for some time because of the printing large chapters.
help, the STARTER cannot be large data volume.
operated for some time
because of the large data
volume.
STARTER_OH - Drive integration
AP00343894 Browsing in the online help for In the online help for drive parameters, the following cross A manual search using the Index or Screen forms - - - - - - - - - - - - - - - - - - X - - - X V3.2
the parameter and fault list references ('see also' or 'further information') are available for a Search is currently possible.
(SINAMICS) fault or alarm under 'Dependency'. Currently, direct access to
the specified alarm or parameter number is not possible.
DCBLib_SINAMICS_RT - DCC
AP00454790 r21002 & r21003 are not r21002 & r21003 are not updated offline (expert list). The parameters r21002 & r21003 can X X - - - - - X X - X X - - X X X X X X X X X V4.3
updated offline. be determined in the "Set Execution
Group" dialog box. The value of
r21002 corresponds to p115[0], r21003
corresponds to r7901[15]
AP01270927 If the block RGJ is operated If the RGJ block is operated with RQN=1 (smoothing on) and In order to prevent that the output - X - - - - - X X - X X - - X X X X - X X X - V4.5
with RQN=1 (smoothing on) CF=1 (output follows input), jumps in the input variable X can value of the RGJ does not ramp-up
and CF=1 (output follows sporadically cause output Y to oscillate above the limits LL and without any limits, ONLY the limited
input) for jumps in the input LU until the input variable is changed again. Therefore, only output YL may be used to interconnect
variable X, sporadically it can output signal YL should be used to interconnect the signal, and the setpoint. The limits LL and LU
occur that output Y oscillates limits LL and LU must be set to the mechanical values must be set to the mechanically
above the limits LL and LU permissible for the particular drive train. The speed limits in the permissible values for the drive train.
until the input variable is drive must also be parameterized so that the limits of the The speed limits in the drive must also
changed again. mechanical system can never be exceeded. be parameterized so that the limits of
the mechanical system can never be
exceeded.

STARTER_V4.5_SP1_Restrictions -4- 18.07.2016


STARTER V4.5 SP1
SIEMENS

ARTS-Plus Brief Description Circumstances Possible work-around Affected DO Drive Family new since
RQ

PB_PN_Commu_SINAMICS

S120 CU310-2 Cranes


DCC SINAMICS

ET200Pro FC-2

S120-ACDrive
DC Master

STARTER
ET200Pro

SCOUT
GM150
GH150

SM120

SM150
G120P

GL150

SL150
G120

G130

G150

S110

S120

S150
DCP
DCC-SINAMICS - Download
TFS39365 No new download when DCC lets you program new block types in the graphical Before a new download with changed - X - - - - - - - - - - - - - - - - X - - - X V2.2
changing the type of library programming language. These block types are managed in library type, restore factory settings
DCC libraries: A block type is created from each DCC chart, (SINAMICS) or delete user data on
and can then be called in the DCC chart. Installable DCB card (SIMOTION)
libraries can be created from the graphically created DCC
libraries via the context menu "Create DCB library". These can
be transported irrespective of a STEP7 project, and can be
used in the DCC chart after installation in STARTER / SCOUT.
Switching from the graphically created DCC library to the
installable library does not require any further changes to the
block calls in the DCC chart. Only the library imported in the
chart must be changed using Options -> Block Types. If a
project with DCC chart is loaded in the target device, and only
the library type is changed in the DCC chart, the DCC charts
are not loaded to the target device again during download.
When loading to the PG into an empty project, an error
message appears: "Upgrading block types is not possible due
to missing libraries. Please install the libraries and re-open the
project."

STARTER_V4.5_SP1_Restrictions -5- 18.07.2016