see notes below 8" outlet will provide 11.5 min drainage time
6" 8" 10" 12" 6" outlet will provide 20 min drainage time
t z1 z2 z3 z4
(min) (ft) (ft) (ft) (ft)
0.00 5.90 5.90 5.90 5.90
0.50 5.62 5.41 5.14 4.83 TIME TO EMPTY TANK FOR DIFFERENT OUTLET SIZES
1.00 5.35 4.94 4.44 3.86
1.50 5.08 4.49 3.79 3.00
7.00
2.00 4.83 4.07 3.18 2.25
2.50 4.58 3.66 2.64 1.61 Column C
3.00 4.33 3.28 2.14 1.08 6.00
Column D
3.50 4.09 2.91 1.69 0.65 Column E
4.00 3.86 2.57 1.30 0.33 5.00 Column B
4.50 3.64 2.25 0.96 0.12
5.00 3.42 1.95 0.67 0.01
4.00
Notes: calculation assumes water as the fluid. There is only an outlet with a valve no pipe length. The valve is a knife gate which has no pressure loss.
the K value is 1 for a simple exit.
Cyclone pump box volume is approximately 24L x 12W x 10H = 2880 ft3, the box is assumed to be half full when a power outage occurs or same area x 5'H
However there is 529 ft3 of slurry dumping into it from other sources, this represents 1.8 ft, I assume that half this volume will drain which makes the pump box height
5 + 1.8/2 = 5.9