Sie sind auf Seite 1von 2

INSTALLATION AND APPLICATION DATA A400PE3

Type of Operation and Application


Item Units 60 Hz
Prime Standby
Rated Speed rpm 1800 1800
Gross Engine Output bhp (kWm) 545 (406.5) 619 (461.7)
Engine
BMEP psi (kPa) 314.8 (2171) 352.4 (2430)
Mean Piston Speed Ft/s (m/s) 30.9 (9.42)
Ambient Air Temperature °F (°C) 131 (55)
Coolant Capacity engine only gal (L) -
Coolant Capacity engine + radiator gal (L) 13.6 (51.4)
Cooling
Cooling system Liquiid (50% water + 50% coolanat)
System
3 3
Pusher Fan Air Flow ft /min (m /s) 27816 - (13.1)
Heat rejection to coolant kcal/kWh -
Heat rejection to air (intercooler) kcal/kWh -
Fuel Type Diesel No.2
Fuel Consumption @ 50% Power gal/hr (L/hr) 13.75 (52) -
Fuel system
Fuel Consumption @ 75% Power gal/hr (L/hr) 19.3 (73) -
Fuel Consumption @ 100% Power gal/hr (L/hr) 24.8 (94) 27.2 (105)
3 3
Combustion Air Flow ft /min (m /min) 950 (26.9) 1052 (29.8)
Air
Air Intake Restriction In.H2O (kPa) 10.5 (2.5)
Requirement
Maximun Allowable Restriction In.H2O (kPa) 26.8 (6.4) -Dirty air filter
3 3
Exhaust Gas Flow ft /min (m /min) 2703 (75.2) 3044 (86.2)
Exhaust
Max temperature, after turbo °F (°C) 1256 (680) 1256 (680)
System
Connection Outlet Size Diameter In. (mm) 5 (127)
Total Engine Oil Cap. w/ Filter(s) gal (L) 10.5 (40)
Oil Filter Type Cartridge
Oil Cooler Water Cooled
Lubrication
System Lube oil specifications API-CH4 - SAE 15W – 40
Lube oil consumption < 0.15% of full load fuel consumption
Oil and filters interval for
hours Check your engine operators book
replacement
Battery Charging Alternator Volts, Ground 24VDC, Negative

Engine Baterry Charging Alternator Rated amps 70


Electricals Recommended Battery Cold Crank CCA amps 1200 (0°F / -18°C)
Starter Motor Volts, Ground 24DC, Negative
temperature % Consult Factory
Ambient altitude > % Consult Factory
Deration
altitude > % Consult Factory
OPTIONAL EQUIPMENT A400PE3
Cooling System Start System Control Panel
 Remote Radiator  Battery Nicad  Emergency stop button
 Jacket Water Heater  Battery Warmer Plate  Microprocessor Control Panel
 Crankcase Oil Heater  Battery Charger  NFPA 110 Ready
Fuel System  Automatic Float Equalizing  Remote Annunciation Panel
 Fuel/Water Separator  Trickle  Audible Alarm
 Day Tank Switchgear General
 Above Ground Fuel Tank  Main Line Circuit Breaker  Spring vibration isolators
 Auxiliary Fuel Pump  Shunt trip  Automatic Transfer Switch
 Sub-Base Fuel Tank  Auxiliary switch  Metal Enclosure
 Double Wall  Automatic Transfer Switch  Interior lights AC or DC
 UL Listed  Paralleling  Trailer
Exhaust System  Protective Relays  Export Packaging
 Industrial Grade Muffler Generator  Special Testing
 Residential Grade Muffler  Permanent Magnet Excitation  Warranties
 Critical Grade Muffler  Space Heaters
 Super Critical Grade Muffler  Temperature Rise Detectors

DIMENSIONS AND WEIGHT

Open Sound Att.


Units
Unit Unit
Length In. (mm) 130 (3302) 178 (4521)
H
Width In. (mm) 50 (1270) 50 (1270)
Height In. (mm) 80 (2032) 88 (2235)
Weight Lbs (kg) 6714 (3041) 7325 (3329)

W L

General configuration for reference only, do not use these dimensions for installation purposes. Contact your
local dealer for certified drawings.

All Specifications and Materials are subject to change without prior notice.

ARMSTRONG POWER SYSTEMS LLC


Phone (305) 470-0058
Fax (305) 470-0068
Toll Free (800) 238-0732
nd
Address: 5100NW 72 Ave., Miami Fl 33166
Email: sales@armstrongpower.com
www.armstrongpower.com

Das könnte Ihnen auch gefallen