Sie sind auf Seite 1von 13

S+S Separation and

Sorting Technology GmbH

Product Purity.
Greater Security.
Added Value.

Control Unit PRIMUS

Electronic control unit for


metal detectors
Control Unit PRIMUS

 S+S standard control unit for


products for the plastics industry

 Easy to control with membrane keys


and LED‘s

 Function „Auto-Set“ for optimum


compensation of product effects and
other influencing factors on-site
(e.g. vibrations or electro smog)

 Digital signal processing via


microprocessor with self-monitoring
and self-adjustment

 Memory space for eight different


products
Control and display elements

1
2
3

6 4

7 5

1 LED-line 8 digits To control the system and give the metal signal (visual)
2 Control buttons +,-,F To control and adjust the control parameters
3 Menu bar 3 parameters To navigate between parameters
4 Function key Reset Reset metal or fault signal
5 Function key Test Test button for metal detection system
6 Red lamp Störung (fault) Blinking in case of fault
7 Red lamp Metall (metal) Glowing in case of metal signal
System design

1 Electronic housing Optional design


2 Electronic board e.g. with integrated belt conveyor
3 Cover plate with control elements control

The electronic housing comes in protection


class IP65 (dust proof and protected against
water jet).
Functional elements on the electronic board

8-fold switch Jumpers for enabling operation Potis EEprom


Machine settings, also features Eject duration Memory for system
accessible for customer, Jumper 1, enable product learning Eject delay and product
e.g. manual / automatic Jumper 2, enable product change MV2 time function parameters
reset Jumper 3, enable sensitivity setting

2-digit 7-segment display


Display for
- Parameter s
- Faults, and
- Time functions

16- pole ribbon cable connector


Connector for Primus control panel

Jumper
Enable parameter
setting

Hex-switch
Parameter selection
(max. 16 parameters)

Mains connector Metal relay External Input/OutCoil connector Coil connector


Mains connector Fault relay 24V put Receiver Transmitter
ext. 24V module connector (compatible with Sensity) (compatible with Sensity)
System connection

 Operating voltage: 100-240 VAC (± 10%) 50/60 Hz

 Current input: Approx. 160 mA/115V, approx. 80mA/230V

 Fuse: 1.6 A slow-blowing

 Mains cable: 1.8 m with plug

 IP rating: IP65

 Reject duration: Adjustable from 0.05 to 29 sec

 Scanning sensitivity: steplessly adjustable

 Self-monitoring: Electronics and sensor function


Inputs and outputs

Switching inputs
 1 reset
 1 manual ejection
 1 compressed-air monitor or thermo switch or filling level monitor
 1 initiator (flap position monitor)

Switching outputs
 2 metal detection
 1 fault signal
 2 switching outputs 24V DC, 100 mA, for metal detection

Options / accessories
 Control Unit remotely installable up to 15 m
 Metal counter
 etc.
Top performance features

 Easy to control with membrane keys


and LED‘s
 Function „Auto-Set“ for optimum
compensation of product effects and
other influencing factors on-site
(e.g. vibrations or electro smog)
 Digital signal processing via
microprocessor with self-monitoring
and self-adjustment

 Ease of use with space for eight


different products, thereof three are
pre-set and optimized for the plastics
industry:
 PM 1: low sensitivity
 PM 2: medium sensitivity
 PM 3: high sensitivity
 PM 4 to 8 can be chosen
individually
Additional performance features

 Ease of use with space for eight


different products, thereof three are
pre-set and optimized for the plastics
industry:
 PM 1: low sensitivity
 PM 2: medium sensitivity
 PM 3: high sensitivity
 PM 4 to 8 can be chosen
individually

 Half wave processing


 Reset-mode can be adjusted
(auto, manually, external)
 Increased interference immunity
against electro smog and vibrations
 System can be locked to prevent false
control (can be activated if needed)
 Self monitoring system with fault
display
 CE-certified by independent institute
Control principle

General control principle:


1. Select parameter with button “F“ (toggle)
2. Adjust parameter with “+/-“ buttons
3. Confirm changes with button “F“
4. Esc/Reset jumps back at any time to initial
status without parameter change

Adjust sensitivity:
1. 1x button “F“
2. Change parameter with ”+/-“ buttons
3. Confirm changes with button “F“

Product change:
1. 2x button “F“
2. Change parameter with ”+/-“ buttons
3. Confirm changes with button “F“

Activate Auto-Set:
1. 3x button “F“
2. Auto-Set starts automatically after three seconds
3. Confirm changes with button “F“
New function „Auto-Set“

 Certain conditions at the place of installation are quite common in the plastics industry and
can influence a metal detector and can lead to false detections:
• Conductive material (e.g. wet material)
• Vibrations
• Electro-smog

 “Auto-Set“ can compensate such environmental influences and delivers optimum scanning
sensitivity and prevents false detections
 Function can be activated individually and automatically on-site by the customer
 The function is being offered in this form by S+S exclusively
Comparison PRIMUS user interface

Original design New as of 06/2013

Improvements:
 Switch +/- buttons for more intuitive control

 Additional LED‘s clearly display at any time, which parameter is being


adjusted at the moment (sensitivity, product change or Auto-Set)

 New function “Auto-Set“ replaces “product teach-in”, the function can


compensate material conductivity as well as vibrations on-site
Thank you very much for your attention.

S+S Separation and Sorting Technology GmbH


Regener Straße 130
D-94513 Schönberg
Germany

Tel: +49 (0) 8554 308-0


www.sesotec.com

Das könnte Ihnen auch gefallen