Sie sind auf Seite 1von 11

Our policy is one of continuous development. Accordingly the design of our products may change at any time.

Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is
intended for information purposes only.
Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot
be held responsible for any reliance on any decisions taken on its contents without specific advice.
Order form MiCOM P141
Ready-to-use configuration

Feeder Management P141 M **


Vx Auxiliary Rating
24 - 32Vdc 9
48 - 110Vdc 2
110 - 250Vdc (100 - 240Vac) 3

In/Vn Rating
In = 1/5A, Vn = 100 - 120Vac 1
In = 1/5A, Vn = 380 - 480Vac (Min 196Vac Max 560Vac) 2

Hardware Options
Standard - None 1
IRIG-B - (Modulated) Only 2
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3) 3
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3) + IRIG-B (Modulated) 4
Ethernet (10 Mbps) 5
Ethernet (100 Mbps) 6
Courier Rear Port 7
IRIG-B (Modulated) & Courier Rear Port 8
Ethernet (100Mbit/s) plus IRIG-B (Modulated) A
Ethernet (100Mbit/s) plus IRIG-B (De-modulated) B
InterMiCOM + Courier Rear Port E
InterMiCOM + Courier Rear Port + IRIG-B modulated F
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Modulated IRIG-B G
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Un-modulated IRIG-B H
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Modulated IRIG-B J
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Un-modulated IRIG-B K
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Modulated IRIG-B L
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Un-modulated IRIG-B M
Redundant Ethernet Parallel Redundancy Protocol (PRP), 2 multimode fibre ports + Modulated IRIG-B N
Redundant Ethernet Parallel Redundancy Protocol (PRP), 2 multimode fibre ports + Un-modulated IRIG-B P
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 2 LC ports + 1 RJ45 port + Modulated/Un-modulated IRIG-B Q
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 3 RJ45 ports + Modulated/Un-modulated IRIG-B R
Ethernet (100Mbit/s), 1 RJ45 port + Modulated/Un-modulated IRIG-B S

Product Specific Option


8 logic inputs & 7 relay outputs A
8 logic inputs & 8 relay outputs N

Protocol / Communications Options


K-Bus with simple password management - CSL0 1
Modbus with simple password management - CSL0 2
IEC 60870-5-103 (VDEW) with simple password management - CSL0 3
DNP3.0 with simple password management - CSL0 4
IEC 61850 Edition 1 / 2 and Courier via rear K-Bus/RS485 with simple password management - CSL0 6
IEC 61850 Edition 1 / 2 and CS103 via rear port RS485 with simple password management - CSL0 7
IEC 61850 Edition 1 / 2 and DNP3 over Ethernet and DNP3.0 via rear RS485 with simple password management - CSL0 B
IEC 61850 Edition 1 / 2 and Courier via rear K-Bus/RS485 with advanced Cyber Security - CSL1 - Security Administration Tool (SAT)
G
required
IEC 61850 Edition 1 / 2 and CS103 via rear port RS485 with advanced Cyber Security - CSL1 - Security Administration Tool (SAT)
H
required
IEC 61850 Edition 1 / 2 and DNP3 over Ethernet and DNP3.0 via rear RS485 with advanced Cyber Security - CSL1 - Security
L
Administration Tool (SAT) required

Mounting Option
Flush Panel Mounting, M

Multilingual Language Option


English, French, German, Spanish 0
English, French, German, Russian 5
Chinese, English or French via HMI, with English or French only via Communications port C

Software Issue **

Customisation
Default 8
Customer specific 9

09/10/2018
Order form configurator MiCOM P141
Ready-to-use configuration

1-4 5 6 7 8 9 10 11 12-13 14 15

Feeder Management Relay P141 2 1 1 A 1 M 0 B2 8 L


SAP PART NUMBER E141211A1M0B28L
Design Suffix
L: Phase 3 CPU L
J: Grey/Grey case, dual characteristic opto inputs, IEC61850, InterMiCOM
Software
B2:
B0:
A1:
A0: B2

Vx Aux Rating
24 - 32Vdc
48 - 110Vdc
2
110 - 250Vdc (100 - 240Vac)
In/Vn Rating
In = 1/5A, Vn = 100-120Vac 1
In = 1/5A, Vn = 380-480Vac (Min 196Vac Max 560Vac)
Hardware Options
Standard - None
IRIG-B (Modulated) Only
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3)
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3) + IRIG-B (Modulated)
Courier Rear Port
IRIG-B (Modulated) & Courier Rear Port
InterMiCOM + Courier Rear Port
InterMiCOM + Courier Rear Port + IRIG-B modulated 1
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 2 LC ports + 1 RJ45 port + Modulated/Un-modulated IRIG-B
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 3 RJ45 ports + Modulated/Un-modulated IRIG-B
Ethernet (100Mbit/s), 1 RJ45 port + Modulated/Un-modulated IRIG-B

Product Specific Options


8 logic inputs & 7 relay outputs A
8 logic inputs & 8 relay outputs
Protocol/Communications Options
K-Bus with simple password management - CSL0
Modbus with simple password management - CSL0
IEC60870-5-103 (VDEW) with simple password management - CSL0 1
DNP3.0 with simple password management - CSL0

Mounting Option
Flush Panel Mounting M
Language
Multilingual - English, French, German, Spanish
Multilingual - English, French, German, Russian 0
Chinese, English or French via HMI with English or French only via Communications port
Customisation
Default 8
Customer Specific

09/10/2018
Master Text

P141211A1M0B28L

Feeder Management Relay

Vx Nominal auxiliary voltage options :


48 - 110Vdc
In/Vn Rating options :
In = 1/5A, Vn = 100-120Vac
Hardware options :
Standard - None
Product specific options :
8 logic inputs & 7 relay outputs
Protocol options :
K-Bus with simple password management - CSL0
Mounting options :
Flush Panel Mounting,
Language options :
Multilingual - English, French, German, Spanish
Software options :
B2
Customisation :
Default

ATEX II (2) G

Page 4 of 11 396710707.xls 09/10/2018


08/08/16
13/07/16
24/09/15
12/05/15
27/11/14
08/07/14
04/02/14
25/06/13
01/10/12
11/09/12
21/08/12
09/08/12
09/07/12
02/06/12
08/05/12
10/03/12
13/02/12
06/02/12
21/11/11
13/09/11
09/08/11
20/02/11
04/10/10
18/08/10
06/08/10
10/06/10
05/05/10
10/02/10
29/01/10
02/12/09
08/05/09
01/04/09
04/03/09
18/12/08
01/12/08
27/08/08
12/08/08
01/07/08
18/03/08
06/03/08
12/04/07
10/02/07
08/01/07

04/08/06

24/07/06
01/06/06
21/03/06
26/10/05
10/10/05
21/03/05
20/12/04
06/12/04
12/10/04
23/06/04
14/06/04

04/05/04
03/05/04
15/03/04
11/03/04
20/02/04
18/02/04
19/01/04
17/11/03
13/09/03
11/04/03
18/02/03
07/11/02
15/08/02
01/06/02
30/11/01
30/11/01
30/11/01
CZHO-ACB869 release of B2 software version
XLAZ-A9Z4AH releases software version A1
CZHO-A2L588 release B0 SW to WPF site for manufacture
CZHO-9W9AWT releases B0 SW with Hardware Options Q,R & S
As per NALW-9Q3DKQ - P140VA0A Major Software Release
As per SBIA-9KBCL4 new power supply option released (9) with (1) removed from option
As per DKEG-9FJDJW power supply voltage amended from 24-48Vdc to 24-32Vdc
SBIA-98UAW2 releases PRP options
"Stand alone non modulated IRIG-B" (digit 7 = C) withdrawn from offer as per Obsolescence program
GN9025 removed from BOM (no longer used)
HMI assembly amended from GN0178001 to 2072033A01 as per JGAR-8X7AQ8
Vx auxiliary rating amended to 48 - 110 Vdc (from 48-110Vdc (40-100Vac)) per CBUN-8WXJKE
Design suffix C & G options removed from offer as per Obsolescence Program
2071962A01 replaces ZN0019001 and 2071966A01 replaces ZN0031001 as per SBIA-8URHXU
Obsolescence warning added to suffix C & G options
PSUs amended to 2071964xxx as per SBIA-8S6A9S
Tendering sheet added
Obsolescence warning added to "Stand alone non modulated IRIG-B" (digit 7 = C) as per latest obsoletion notice
SW Version 21 released to SMC production, per approved TOMAS request 213
SW Version 46 released to production, incorporates rebrand and several other enhancements
Update as per latest AG obsoletion notice
Reworked for Schneider Electric requirements
References to Alstom and Areva removed. 'Settings files' changed to 'Customisation'
Lookup correction for Suffix 'G' & UCA2 Protocol
BOM rules clarified on change for AS above
CID ISTE-85VFU7 removes software versions '10' & '16'
PCB descriptions on BOM clarified
44' Software released by CID ISTE-82HLT5, includes model 'N'
BOM modified in line with PWIG-7ZHCJK making ZN0031001 a model list variable
Redundant Ethernet optons made available, see CIDs ISTE-7YAMBJ & SKEL-7YBM34
43' Software released, Redundant Ethernet optons added though set as 'not available', see CID ISTE-7RMDSS
Lookup array on database for Master Text "hardware options" corrected
Vx rating changed in line with CID BLIN-7P7HJX
Correction to lookup address for Protocols (did use "HLOOKUP('Date Drivers'!$B$1,'Date Drivers'!$B$2:$Y$18,9) for DNP3.0
"42…J" software released by CID ISTE-7LCFEC, also restriction to protocol availability on version '17' software, see CID ISTE
BOM retrospectively amended to include GN0178001AREVA for G Suffix, Russian language options
Explanatory text retrospectively added to '35' software per G Evans
"41…J" software released by CID GEVA-7FZEF2, BOM rules corrected for UI & suffix 'G'
Software versions prior to '05' removed from Cortec to maintain concordance with Software History and Compatibility database
"40…J" software released by CID GEVA-7CEFKM
"36…J" software released by CID GEVA-726JEM
Chinese language version was not included in Software Version '35' options
Cortec & Date Drivers retrospectively amended to show revised text for IEC 61850 Comms Protocol (was "IEC 61850" only)
Cortec & Database corrected to show IRIG-B (De-Modulated) option as cortec code "C" (was "9" in error) and changing effecti
BOM, Cortec, Database & Date Drivers changed to include IEC 61850 protocol with 100Mbit/s Ethernet comms. and IRIG-B (M
Modulated) options with notional effective date of 24/07/06 for testing
BOM amended. Cortec & Date Drivers text changed for what was just "Chinese HMI"
"34…J" Software and Chinese HMI added in line with G Evans' e-mail dated 15/03/06, with a guestimated DC date of 21/03/06
amendment
"32…J" Software released with a DC date of 26/10/05 nb: ethernet options are not available with this issue - CDN R5760
Power Supply ZN0021*** changed retrospectively to ZN0001*** for 'B' design suffix versions
Hardware options 3 & 4 read "Fibre Optic Converter Only" & "IRIG-B and Fibre Optic Converter"
Configurator amended to allow choice of design suffix and software first to drive the subsequent options
"30…J" Software/Hardware released with DC date of 07/01/05
Livery Option added
Dates amended on Lookup to pick up correct final assembly according to design suffix
Lookup dates corrected for Input Module so that one day only entry for 21G, so that it correctly picks up the phase 2 module -
"21…G" Software/Hardware released as per CDN R3500/193, this is released as One Day Only as "15…C" is latest unless cu
requests "21G"
"21…G" Software/Hardware added with estimated release date of 07/05/04
Phantom Final Assembly corrected for Suffix "G" by adding date driver to Lookup2 - 15/03/04
Rules modified for Ethernet Licences ZB9800801 & ZB9800802
"17…C" Software/Hardware released for 1 DAY ONLY for CRUICKSHANKS order on authority of G Evans e-mail
"20…G" Software/Hardware release date with "…/Russian" language option was 16/02/04, now 01/06/04 - 18/2/04
"20…G" Software/Hardware release date with "…/Russian" language option was 19/01/04, now 16/02/04
"20…G" Software/Hardware release date with "…/Russian" language option was 01/04/04, now 19/01/04
Design suffix was "C" for all. Now "C" only for "Rear Comms" variants & "B" for the rest
UCA2/Ethernet not available as yet, release date delayed indefinitely
P141 Cortec created from P14x, now includes UCA2 / Ethernet from 01/03/2003
Rear comms available from 18/11/02
Qty ZB4018110 was 2 less for P14***7******** variants
Incorporate P144
Slot 05 pcb for P142***C******B variants was ZN0017001 in error
Hardware option 4 specified Protocol option 4 in error
Original
BOM

Qty.
NUMBER DESCRIPTION Ref
Required
P141211A1M0B28L
GN0010073 ANALOGUE INPUT MODULE 23 1
2072033A01 F/ASSY USER INTERFACE 40TE (PHASE 2) 22 1
GN0249001 COMMON PARTS 1
GN2037001 BLANKING PLATE. 34 1
ZB4018110 Self tapping screw pan head size 4 X ¼" 60 8
ZB4018215 SELF TAP SCREW SIZE 6x1/4" LG (KAN) 61 2
2071964A02 PSU 48/125V 1 1
2071966A01 Relay Output PCB 2 1

Page 9 of 11 396710707.xls 09/10/2018


1 2 3 4 5 6 7 8 9 10 11 12 13 14

Cortec Landing cell : P14122JA8M5439J P 1 4 1 2 2 J A 8 M 5 4 3 9


Configurator feedback : P141211A1M0B28L P 1 4 1 2 1 1 A 1 M 0 B 2 8
0
Cortec digit control 1 P
Cortec digit control 2 1
Cortec digit control 3 4
Cortec digit control 4 1
Vx Aux Rating 2 2
In/Vn Rating 1 1
Hardware Options 1 1
Product Specific Options 1 A
Protocol/Communications 1 1
Mounting Option 1 M
Language 1 0
Software 1 B 2
Customisation 1 8
Design Suffix 1
15 20 20

J
L double digit in same row

5
6
7
8
9
10
11
12
13
14
15
16
17
L 18
0
0
0
0
0
0
0
0
0
0
0
0

Das könnte Ihnen auch gefallen