Sie sind auf Seite 1von 6

Doppler open channel flow meter

SLK - DFMP
Description:

A. Speed area method flow meter composition principle

1. For the measurement of channel, culvert, non-full pipe, river (lake)

channel flow, the flow meter adopts the speed area method measurement

principle, that is, the liquid level sensor measures the liquid level

value, the flow rate flow sensor measures the flow rate, and the channel

flow rate measurement is different from the pipeline. With the change

of flow rate and water level, the flow velocity of each section of the

channel flow is also changing, and the difference is relatively large.

Therefore, multi-section multi-channel measurement is selected

according to the size of the channel, and the average flow rate and the

measured liquid level value are calculated. Flow value. Generally

speaking, for channels with a water depth of more than 1 meter,

three-channel section measurement should be used. The more channels, the

more accurate the flow rate measurement is. The lower sensor position

is 100mm higher than the bottom of the channel to ensure that it is not

covered by mud. The upper sensor is exposed to the water surface.

Automatic judgment.

2. Level measurement: Ultrasonic or pressure level sensor for level

measurement.

3. Flow rate measurement: According to the water quality of the measured


medium, Doppler method and time difference method are used to measure.

The choice of sensor is especially important in actual measurement.

B. Sensor selection:

In the actual measurement, in order to ensure scientific and reasonable

measurement, different flow rate measurement methods should be selected

according to different water quality. The company also masters the key

techniques of time difference method and Doppler method. The time

difference method is used to measure liquid with single water or solid

particle/bubble concentration below 75ppm. Doppler law is used for liquid

larger than solid particle/bubble concentration below 75ppm. According

to the actual measured liquid condition, the optimal measurement method

is selected, and finally the stable and accurate measurement result is

achieved.

C. Application

It is applicable to the measurement of flow rate and flow rate of pipelines,

rivers, lakes, channels and culverts, measurement of agricultural water

conservancy open channel, environmental discharge flow measurement, and

sewage water inlet and outlet drainage.明渠超声波

Schematic diagram:
Specification:

Category Specifications

Measuring principle Velocity area method

Sensor Doppler sensor

Soundtrack 1——8channel

Accuracy 2%

Measuring range 0-12m/s

Level measuring Ultrasonic,plug-in

Range 0-30m

Accuracy 1%—2%

Resolution 1mm

Unit display Four lines display ,level,flow velocity,traffic

and cumulative traffic

Medium Agricultural water conservancy river channel,

sewage factory,discharge river and other channel

Working temperature Unit:—10—— +70℃;Sensor—30—— +160℃

Signal output 4-20mA,1~5V

Communication RS485/Modbus
Power supply Isolation DC12--24V 或 AC220V

Power consumption <10w