CONTACTORS TECHNICAL INFORMATION & CONTACTORS

Rainproof Pullout Type Disconnects Switched Safety Enclosures


for Air Conditioning Application
Switched Disconnect
Non-fused and fused versions available.
• Nonmetallic enclosure is Type 4X washdown resistant and non-conductive
Single Phase - 240VAC - with two wire equipment ground to case. NEMA 3R • Internal frame bonds all grounds automatically
rainproof, metallic/galvanized steel enclosure. Horsepower ratings apply • Accepts auxiliary contacts to extend the function of the device
when time delay fuses are used. • Lockable highly visible red handle to meet OSHA lock/tagout regulations
Amp Voltage Type Mfr’s # Order # Price Ea.
30 600V AC (max) Unfused HBLDS3 54034624 $248.54
Fuse Size (In.) Wt. 60 600V AC (max) Unfused HBLDS6 54034632 372.35
Amps Type HP Width Height Depth (Lbs.) Mfr’s # Order # Price Ea. 100 600V AC (max) Unfused HBLDS10 54034640 501.62
60 Cartridge 10 Max 57⁄16 813⁄16 33⁄16 4.5 DPF222R 00438655 $43.01 30 600V AC (max) Fused FDS30 54034657 974.27
60 Non-Fusible 10 Max 57⁄16 813⁄16 33⁄16 4.5 DPU222R 00438648 40.42 60 600V AC (max) Fused FDS60 54034665 1137.01

Basics of...Contactors
A contactor does not provide overload protection. Contactors are used to electrically turn on or off high current, non-motor loads or in motor circuits where overload
protection is separately provided. The contactor operates by applying a control voltage to the contactor coil. When the coil is energized, the movable contacts are
closed against the stationary contacts, thus completing the circuit. The contactor is therefore used to supply and interrupt power to an electrical load.
NEMA Contactors. NEMA (National Electrical Manufacturers’ Association) establishes product design standards and test specifications for these contactors. These
contactors are capable of general jogging and reversing duty. NEMA contactors can be applied with limit application information.
IEC Contactors. IEC (International Electrotechnical Commission) publishes recommendations for certain product design parameters and laboratory test procedures. In
general, IEC standards allow the contactor to have a smaller creepage path and a higher temperature rise than NEMA, which results in a smaller physical size. Also,
when sizing an IEC contactor, knowing an application’s duty cycle and jogging and reversing characteristics becomes important.

NEMA Rated AC Contactors Definite Purpose Contactors - 3 Pole


Lighting Electrically Held - Type CN35 magnetically held, designed to handle the switching of
tungsten (incandescent filament) or ballast (fluorescent and mercury arc) lamp loads as well as Type C25 Definite Purpose contactors, through 60 amperes, incorporate
other non-motor (resistive) loads. Coil voltage 120/60 or 110/50. competitive contactor mounting dimensions into a single baseplate. Furnished
with pressure plate connectors and quick connect terminals as standard on 15,
LOADS 25, and 30A devices and with box lugs and quick connect terminals on 40, 50,
Ballast Lamps = Fluorescent, Mercury Vapor, Sodium Vapor, Quartz - 600V maximum. and 60A. Coil Voltage 120V, 50/60 Hz.
Filament Lamps = Incandescent, Infrared, Sodium Iodine, Heating - 480V maximum.
Resistance Heating = Radiant and convection heating, furnaces and ovens. C25 Contactors - Open Type
Max. Ampere No. of Frame Amperes Maximum Motor
Rating Poles Size (mm) Mfr’s # Order # Price Ea. Inductive Resistive Horsepower Kilowatts No. of
Full Load Per Pole 1 Phase 3 Phase 1 Phase 3 Phase Mfr’s # Poles Order # Price Ea.
10A 3 45 CN35AN3AB 00535591 $161.39
20A 3 45 CN35BN3AB 00535609 203.50 15 20 2 3 1.5 2.2 C25DND315A 3 02351823 $44.84
30A 3 45 CN35DN3AB 00535617 237.39 25 35 3 7.5 2.2 5.5 C25DND325A 3 02351831 50.02
60A 3 65 CN35GN3AB 00535625 432.92 30 40 5 10 3.7 7.5 C25DND330A 3 02351849 54.33
100A 3 90 CN35KN3A 00535633 698.29 40 50 7 10 5.5 7.5 C25DNF340A 3 02351856 65.42
50 65 10 15 7.5 11 C25FNF350A 3 02351864 115.80
60 75 10 20 7.5 15 C25FNF360A 3 02351872 136.31
75 90 15 20 11 18.5 C25FNF375A 3 02351880 183.73
90 120 20 30 15.1 22 C25GNF390A 3 02351898 228.20

Mechanically Held Lighting Contactors


• Designed and tested specifically for lighting and resistive loads • Hold up to 12 poles in compact frame
No. of Amp Coil 2-Wire 3-Wire
Poles Rating Voltage Mfr’s # Order # Price Ea. Mfr’s # Order # Price Ea.
2 30 120 C30CNM20A02A0 06678882 $505.07 C30CNM20A03A0 06678890 $534.22
4 30 120 C30CNM40A02A0 79774063 645.91 C30CNM40A03A0 06678908 670.20
6 30 120 C30CNM60A02A0 06678916 869.32 C30CNM60A03A0 06678924 897.33
8 30 120 C30CNM80A02A0 06678932 1053.85 C30CNM80A03A0 06678940 1073.28
10 30 120 C30CNM100A02A0 06678841 1209.26 C30CNM100A03A0 06678858 1233.55
12 30 120 C30CNM120A02A0 06678866 1340.38 C30CNM120A03A0 06678874 1364.67 06678841

Noncombination Enclosed Lighting Contactors


Electrically & Mechanically Held
• Designed and tested specifically for lighting and resistive loads
• Hold up to 12 poles in compact frame • 6.75wD x 7.73w x 13.21wH

No. of Amp Coil Electrically Held Mechanically Held


Poles Rating Voltage Mfr’s # Order # Price Ea. Mfr’s # Order # Price Ea.
2 30 120 ECC03C1A2A 02300861 $386.99 ECC04C1A2A 02300598 $586.34
4 30 120 ECC03C1A4A 02300879 543.70 ECC04C1A4A 86856275 730.25
6 30 120 ECC03C1A6A 02300887 708.93 ECC04C1A6A 02300614 980.77
8 30 120 ECC03C1A8A 02300895 858.18 ECC04C1A8A 02300622 1172.66
10 30 120 ECC03C1AAA 02300846 1028.74 ECC04C1AAA 02300572 1348.56
12 30 120 ECC03C1ABA 02300853 1108.69 ECC04C1ABA 02300580 1471.15 Electrically Held Mechanically Held