Switching Units
Selection Table for ESR Units
3 IP 30 2 2 230/115/24 x ESD 3
1 IP 30 2 1 230/115/24 ESR 11
1 IP 30 2 2 230/115/24 ESR 12
1 IP 30 2 1 230/115/24 ESR 13
2 IP 30 2 1 24 x ESR 25
2 IP 30 2 2 24 x ESR 26
2 IP 65 1 1 230/115/24 x ESA/ESP
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 1
Switching Units
ESD3
• DIN Housing
• Safety Category 3 according EN954-1
• For contact mats acc. to EN 1760-1 /
for safety edges acc. to EN 1760-2
• Auto, External Reset
Terminal Terminal
1 Signal Sensor 1 9 Supply Voltage
Upper
~11 kOhm 2 Signal Sensor 1 10 Supply Voltage
Switching 3 Signal Sensor 2 11 –
Resistance
Terminals
• type: 2 x 8 pole plugable
• max. cross-section 2.5 mm 2
2 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Variation Table
The ESD3 variants are distinguished firstly by their reset function and secondly by the configuration of the status relay contact.
This can be implemented off-load both as open and closed. It is not a safety contact, but is exclusively used for transmitting
information. It is not monitored for failure and must never be used for safety shutdown in any form whatsoever.
Each type is available in three voltage supply variants: 24 V AC/DC, 115 V AC, 230 V AC.
03 x x x x
04 x x x x
05 x x x x
06 x x x x
08 x x x x
09 x x x x
03C x x x x
05C x x x x
Legend:
O = Contact open
X = Contact closed
Reset
Auto-Reset
• NO button on the front
• Reset electronically integrated
External Reset
• NO button on the front
• external button (NC)
• Terminals 5,6
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 3
Technical data Dimension Sheet
– Housing DIN ABS, red/black
– Isolation Class IP 30 (IEC 529)
– Protection Class IP54
– Weight max.250 gramm (depending on type)
– Power Supply 24 VACDC ±10%
acc. to EN60204-1 115 VAC ±10%
(depending on type) 230 VAC ±10%
105
– Frequency Range 50/60 Hz (45–66 Hz)
– Power consumption max. 5 VA
– Duty Cycle 100%
– Fastening 35 mm mounting rail acc. to EN50022
79
ción Po
Fun Commutazione we
Arrê r
4 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Switching Units
ESR-1/-3
• Safety Category 1, 3, according to CEN
• Bircher M3 Housing
• 11-pin Plug
• Large Selection
~11 kOhm
Upper
Switching ESR-12
Resistance
Threshold
In addition to ESR-11
Sensor
Nominal
8.2 kOhm • Simple signal evaluation per output
Resistance
~6.2 kOhm F1
Lower
Switching
Threshold P
F2 F3
Signal Output
Relay Contacts 14(3)
Sensor 22(5) F 12(4)
32(8) S
1 11(1)
Sensor 24(7) F 31(11)
34(9) S
2 21(6)
A1(2)
A2(10)
Connection M M
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 5
ESR-13 Technical data ESR-1
In addition to ESR-11
• Error indication connection Housing Type M3, Material Red Noryl
Isolation Class IP 30 (IEC 529)
Weight max. 250 gramm (depending
F1 on type)
P Power Supply DC voltages are battery power
F2 only
14(3)
Sensor 22(5) F 12(4) - Type ESR-1. -24VADC 24-36VAC/24-48VDC (±20%)
32(8) S
1 11(1)
24(7) 31(11)
- Type ESR-1. -115VAC (+10%/–20%) with isolating
Sensor F
34(9)
2 S
21(6) transformer
A1(2)
- Type ESR-1. -230VAC (+10%/–20%) with isolating
Error collecting
A2(10)
Indicators LED 5 mm
- Operation Green
- Function Yellow
36 12 85
-Error Red
Reaction Time < 70 ms
Temperature Range
- Operation –20°C to +50°C
- Storage –20°C to +80°C
Humidity max. 80% relative
6 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Switching Units
ESR25/26
• 11 Pin Plugable Socket
• GS-BE-17 and ZH 1/494
• 1-/2-Channel
General Connection
The difference between the ESR25 and ESR26 is that the • max. total length of sensor with cable 50 m
ESR26 has two separate evaluation circuits. • max. total area of sensor 5 m2
• multiple sensors are connected in series
• the total resistance must not exceed 8.2 kOhm
Function
Important: • The installed fuse is absolutely neccesary. It
Connected sensors are monitored with a terminating protects the relay contacts against «welding»
resistance of 8.2 kOhm to detect changes in the constant when overloaded.
flowing zero-signal current. Both relays are energised in • Suppressors (220 Ohms/0.1 µF) are to be
the non-active condition. connected across the connected loads.
• Periodical function test are to be made. The
If one or more sensors are activated designated test contacts are to be bridged (see
• the total resistance drops towards zero ohm Layout). The applied tests are to be docu-
• when the resistance falls below the defined limit (approx. mented.
2 kOhm) • Further installation instructions can be ob-
• the relays de-energise tained from the operators manual enclosed
• the yellow LED illuminates with the product.
Terminal/Connections
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 7
Block Diagram Technical Data
Housing NORYL, red
11(1)
Face Black
Sensor 22(5) Dimensions 85 x 74 x 36 mm
32(8)
1 R1
24(7)
Drive Plug-socket 11-Pin
Sensor Circuit
2
34(9) F1 Isolation Class IP30
R3
or 8.2kOhm resistance
21(6) Isolation Class IP54
Supply A1(2) Application area
Voltage A2(10)
Temperature Range –20°C +55°C
Power Supply 24 VACDC ±10%
Frequency 50/60 Hz
ESR25 Power Consumption
• two parallel sensor inputs - ESR25 < 3 VA
• safety output - ESR26 < 5 VA
• supply voltage 24VACDC Sensor Input ESR25
• redundant evaluation of the sensor - Reaction Value
«Activated» < 2.3–2.5 kOhm
- Reaction Value
«Interruption» > 8.9–10.4 kOhm
11(1) Sensor Input ESR26
22(5)
Sensor - Reaction Value
32(8)
1 R1
Drive «Activated» < 1.4–1.8 kOhm
Circuit 1
R3
F1 - Reaction Value
21(6) «Interruption» > 8.6–9.3 kOhm
24(7) 14(3) - Reaction Time max. 12 ms
Sensor 34(9)
2 R2 Drive Signal Output Relay 2 A/50 VAC per channel
Circuit 2 Display LED 3 mm
F2
R4
12(4) - Operation Green
Supply A1(2) - Safety Switch-off Yellow
Voltage A2(10) - Error (Interruption)
Red
Test Specifications GS-BE-17 (April ‘98) and
ZH 1/494
(Issue August 1994)
ESR26 Overvoltage Category II (EN 61010-1)
• two separate sensor inputs Contamination Grade 2 (EN 61010-1)
• two separate safety outputs Protection Class 0 (EN 60730-1 and EN 60335-1)
• supply voltage 24VACDC
• redundant evaluation of both channels
LED Status
8 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Layout Dimension Sheet
ESR25
F1
74
REL1
J1 LED
REL3 4
J4
3
2
1 36 12 85
Ordering Information
ESR26
e.g. ESR25-24VACDC
F1
Type
REL1 J3 ESR25
J1 LED ESR26
REL3 4
J4
3 Supply Voltage
F2
2 24ACDC
REL2 J2 1
6
REL4 5
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 9
Switching Unit
1 3
Wiring Diagram Sensor
2
Safety
For each sensor two redundant channels are available. The Circuit
two output contacts are connected in series and protected
with a fuse. 4
3
Sensor
1 τ Restart
2 8
Drice
Circuit
5 ~
Supply =
6
4
ESAS 25 / ESPS 25
5 ~
Supply =
6
ESA 25 / ESP 25
10 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
ESAT 25, ESPT 25 / Service Door Technical data
• Basic function as ESA 25/ESP 25
ESA 25 ESP 25
• Additional input for service door function
Housing ABS grey –
• Output for ermergency stop circuit
transparent cover –
Dimensions 80 x 110 x 65 70 x 94
1 3
Sensor - Protection Class IP65 IP00
2
Safety - Cable gland 3 x PG9 –
Circuit Supply Voltage 230 VAC (+10/–20%)
with isolating trafo
4
115 VAC (+10/–20%)
7 with isolating trafo
τ Restart
8 24 VADC (+10/–10%)
Frequency Range 50/60 Hz
11
Service 9 Emergency Power Consumption max. 4 VA
Door 10 Stop Circuit Sensor Inputs
12
5
- Input resistance 5 kOhm to 12 V (internally)
Supply ~
6 = - Input voltage with
8.2kOhm approx. 7.5 VDC
ESAT 25 / ESPT 25 Signal Output Relay
- Switching Capacity 2 A/250 VAC
- Reaction time < 15 ms
Connection
- Reaction time
• The maximum length of the Sensor must not exceed by interrupt < 15 ms
50 metres Indicators LED 3 mm
• Maximum surface area 5 m2 - Operation Green
• Multiple Sensors are to be connected in series - Safety Shutdown Yellow (2 off)
• The total resistance must not exceed 8.2 kOhm - Error (interrupt) Red (2 off)
Temperature Range –20°C to 55°C
Important: Testing Basis GS-BE 17 and ZH 1/494
• the installed fuse is absolutely necessary
- to protect the relay contacts from «welding» when Additional Data
overloaded
Function «Restart» ESA 25 ESP 25
• Suppressors (Type 220 Ohm/0.1 µF) are to be connected
Housing see ESA
across inductive loads
Cable Gland 1 x PG7, 3xPG9 –
Relay fro Restart Function
The assembly and operating instructions are
- Switching Capacity 2A/250VAC
described in the Assembly and Operating
- Time Delay 1…1.5sec
Manuals supplied with the product.
- Impulse Time 1.5…2sec
Status LED
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 11
Dimension Sheets Print Version
Installation Housing
LED2 LED3
J1 LED4 LED5
110 65
1.5
=
90 J2
LED1
TR1
¢4.4
70
REL2 REL1
12
80
60
=
F1
56
3 4
75
94
LED4 LED5
=
J2
LED1
80
60
TR1
70
REL2 REL1
1 2 REL3
=
F1
56
78 3 4
PG7 PG9
75
ESAS 25 94
105 5 61 ESAS/ESPS
Terminals/Connection Layout:
3,4 Safety Circuit – 7,8 Restart – 5,6 Supply – 1,2 Sensor
20
65.5
105
LED2 LED3
J1
LED4 LED5
J2
=
LED1
TR1
REL3 REL2 REL1
94
4xPG7 PG9
F1
ESAT 25 1 2 9 10 REL4
=
11 12 7 8 3 4 56
12 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Overview ESA/ESP
DOOR
Total SERVICE
Programme
OPEN
ESA 25
ESA 25-R
ESA 25-D
ESAS 25
ESAS 25-R
ESAS 25-D
ESAT 25
ESAT 25-R
ESAT 25-D
ESP 25
ESP 25-R
ESP 25-D
ESPS 25
ESPS 25-R
ESPS 25-D
ESPT 25
ESPT 25-R
ESPT 25-D
ESZ-25
ESZ-25.D
ESZS-25
ESZS-25-D
Order Information
e. g. ESPT 25-230 AC
Type
ESA Standard Unit
ESP Standard Print Version
ESAS Stop-Restart
ESPS Stop-Restart Print Version
ESAT Service Door
ESPT Service Door Print Version
ESZ plugable
Supply Voltage
24VADC
115VAC
D53 004 E 06/05
230VAC
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 13
Switching Units
ESQ
• GS-BE17 and ZH 1/494
• 4-channel
• Housing IP65
• Redundant evaluation
Connection
• max. total length of one sensor system with cable 50 m
• max. total area of one sensor system 5 m2
General
• multiple sensors are connected in series
The ESQ is a electronic switching unit of the ES family. It • the total resistance must not exceed 8.2 kOhm
controls sensors to a zero-signal current.
Important
• the installed fuse is absolutely necessary. It protects the
Function relay contacts against «welding» when overloaded.
Connected sensors are monitored with a terminating resi- • Suppressors (220 Ohms/0.1 µF) are to be connected
stance of 8.2 kOhm to detect changes in the constant flow- across the inductive loads.
ing zero-signal current. All relays are energised in the non • Periodical function tests are to be made (see Assembly,
active condition. Commissioning, Periodical Tests)
14 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Status LED
Terminal/Connections
1,2 Sensor-Input 1
3,4 Sensor-Input 2
5,6 Sensor-Input 3
7,8 Sensor-Input 4
9,10 Supply 24VACDC
11,12 Service-Output1
13,14 Service-Output 2
15,16 Service-Output 3
17,18 Service-Output 4
19,20 Safety-Output
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 15
Block Diagram Tecnical Data
1
11 Housing ABS, gray, cover
transparent
2
12 Dimensions 120 x 200 x 75 mm
Isolation Class IP65
Temperature Range –20°C to 55°C
13
3 Power Supply 24 VACDC ±10%
4
Frequency 50/60 Hz
14 Power Consumption < 6 VA
Reaction Time max. 15 ms
15
Signal Output Relay
5
- Safety 2 A/250 VAC
6 - Service 2A/250VAC per channel
16
Display LED 3 mm
- Operation green
7
17 - Safety Switch-off yellow (2 for status relay)
- Error (Interruption) red (2 per channel)
8
18 - Service yellow (2 per channel)
19
Overvoltage II (EN 61010-1)
1
Contamination Grade 2 (EN 61010-1)
2AT Test Specifications GS-BE-17 (Aug. 94)
and ZH 1/494
1 Protection Class 0 (EN 60730-1 and EN
20
60335)
9 7812 7812
RED
YELLOW
10
16 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Layout Dimension Sheet
9 LED1
J1 LED5
10 LED2 REL 1 11
LED3
LED23 J2 12
LED4
13
LED6 LED10 REL 2 14
J3
120
90
LED7
LED8
J4
LED9 LED21 REL 5 19
100
90
1
LED11 20
2 J5 LED22
LED12 REL 6
3 F1
LED13
4 J6 188,3
LED14 LED15 15 200
5 REL 3 16
LED16 75
6 J7
LED17 17
7
LED18 LED20 REL 4 18
8 J8
LED19
138,2
160
red
yellow
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 17