E S D, E S R , E S A , E S P, E S Q

Switching Units
Selection Table for ESR Units

Safety Protection Sensor Sensor Bircher


Category Class Inputs Outputs Voltage Redundancy Type

3 IP 30 2 2 230/115/24 x ESD 3

1 IP 30 2 1 230/115/24 ESR 11

1 IP 30 2 2 230/115/24 ESR 12

1 IP 30 2 1 230/115/24 ESR 13

2 IP 30 2 1 24 x ESR 25

2 IP 30 2 2 24 x ESR 26

2 IP 65 1 1 230/115/24 x ESA/ESP

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 1
Switching Units

ESD3
• DIN Housing
• Safety Category 3 according EN954-1
• For contact mats acc. to EN 1760-1 /
for safety edges acc. to EN 1760-2
• Auto, External Reset

Switching Units monitor tactile signal sensors such as Type ESD-3


safety mats, contact strips and bumper systems
• safety Category 3 according to EN954-1
• self-monitoring
• double redundant signal evaluation
Function • automatic or external Reset
Connected Sensors have a terminal resistance of 8.2 kOhm • fail-safe
and are monitored for changes in the continously flowing • force guided relay
no-load current. In the non-activated condition both relays
are energised.
Block Diagram and Connection
When one or more Sensors are activated
• the total resistance sinks towards zero ohm 12
• if the value falls below the defined threshold (6.2 kOhm)
• the relays are de-energised 1
Sensor 1
• the yellow LED illuminates 2
13
15
3
Sensor 2
When a Error occurs in the Sensor circuit 4
• the total resistance rises towards infinity if the value
rises above the defined threshold (11 kOhm) * 5 16
6 7
• the relays are de-energised
• the red LED illuminates 8
9
10

Terminal Terminal
1 Signal Sensor 1 9 Supply Voltage
Upper
~11 kOhm 2 Signal Sensor 1 10 Supply Voltage
Switching 3 Signal Sensor 2 11 –
Resistance

Threshold 4 Signal Sensor 2 12 Safety Output Relay 1


Sensor

5 External Reset 13 Safety Output Relay 1


8,2 kOhm
Nominal 6 External Reset 14 –
Resistance
7 Indication Relay 15 Safety Output Relay 2
~6,2 kOhm
Lower 8 Indication Relay 16 Safety Output Relay 2
Switching
Threshold *Versions with automatic reset have this function integrated in the
circuit
Signal Output
Relay Contacts

Terminals
• type: 2 x 8 pole plugable
• max. cross-section 2.5 mm 2

2 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Variation Table

The ESD3 variants are distinguished firstly by their reset function and secondly by the configuration of the status relay contact.
This can be implemented off-load both as open and closed. It is not a safety contact, but is exclusively used for transmitting
information. It is not monitored for failure and must never be used for safety shutdown in any form whatsoever.
Each type is available in three voltage supply variants: 24 V AC/DC, 115 V AC, 230 V AC.

Version Inputs Safety Relay Reset Status Relay


2 Separation Auto External M SM C D

03 x x x x
04 x x x x
05 x x x x
06 x x x x
08 x x x x
09 x x x x

03C x x x x
05C x x x x

Function Status Relay

Contacts Type No voltage Sensor Sensor Error


not operated operated (LED red)
(LED yellow)

Safety contact all Types O X O O

Error Indication contact SM ESD3-03,-05 O X X O


Error Indication contact C ESD3-03C,-05C X O O X
Indication contact M ESD3-04,-06 O X O O
Indication contact D ESD3-08,-09 X O X X

Legend:
O = Contact open
X = Contact closed

Reset
Auto-Reset
• NO button on the front
• Reset electronically integrated

External Reset
• NO button on the front
• external button (NC)
• Terminals 5,6

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 3
Technical data Dimension Sheet
– Housing DIN ABS, red/black
– Isolation Class IP 30 (IEC 529)
– Protection Class IP54
– Weight max.250 gramm (depending on type)
– Power Supply 24 VACDC ±10%
acc. to EN60204-1 115 VAC ±10%
(depending on type) 230 VAC ±10%

105
– Frequency Range 50/60 Hz (45–66 Hz)
– Power consumption max. 5 VA
– Duty Cycle 100%
– Fastening 35 mm mounting rail acc. to EN50022

Safety Output Relay


– Utilization category AC-1: 250V/2 A /500 VA
acc.to EN60947-4-1* approx. 300’000 switchings
45
DC-1: 24V/2 A/48W
approx. 700’000 switchings
Stick-on labels in the
– Utilization category AC-15: 250V/2 A /500 VA following languages:
acc.to EN60947-5-1* approx. 130’000 switchings en, fr, it, es, sv
(DC13: 6 switchings/ DC-13: 24V/2 A/48W
minute) approx. 70’000 switchings Funzione
Serv
ice

79
ción Po
Fun Commutazione we
Arrê r

– Contacts positively driven relays, AgCuNi


di sicurezza sé t de
cia curit S
sen é S afe
Pre to ty
ift AnomaliaDD 3ér p
Dr ts S
E dé
periferica anESD3
ge S
kre del D3 tecteuErmeen ns t
ds
– Operating Life Mechanical 50 million switchings yd
Sk tiv
ak
el
a llo
F sor S
sen E
r r o
or r
ESD
3
arf ES
Giv
– Fuse Protection 2 A slow D
3

Error Signal Indicator Relay


– Switching Capacity 24VDC /1A, resistive load
30 VAC /1 A, resistive load
Detailed assembly and operating information can
be obtained from the Operating Instructions
Indicators LED 3 mm enclosed with the product
– Operation Green
– Error Red (sensor resp. system error)
– Safety Switch-off Yellow (sensor)
Order Information
Reaction Time
– Sensor relay < 50 ms
e.g. ESD3-03 - 230 AC
Temperature Range
– Operation –20°C to +55°C Type
– Storage –20°C to +80°C ESD3-03
etc.
Humidity max. 80% relative see variation table
(no condensation allowed)
Supply voltage
*If not mentioned ratings are required, ask for them at 230 AC
the manufacturer. 115 AC
24 ACDC
For 24 VACDC supply voltage must be obtained from
a safety trafo according to IEC742. The wiring must be
protected against mechanical damage.

Specifications are liable to change in accordance with


product improvement.
D53 001 E 06/05

4 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Switching Units

ESR-1/-3
• Safety Category 1, 3, according to CEN
• Bircher M3 Housing
• 11-pin Plug
• Large Selection

Switching Units ESR Type ESR-1


Connected Sensors are monitored for changes in the con- ESR-11
tinously flowing no-load current. • Safety Category 1
In the non-activated condition both relays are energised. • Two channel design
• Simple signal evaluation
When one or more Sensors are activated • Recognition of Sensor Errors
• the total resistance sinks towards zero ohm
• if the value falls below the defined threshold (6 kOhm) F1
• the relays are de-energised P
• the yellow LED illuminates F2 F2a F2b
14(3)
Sensor 22(5) 12(4)
When a Error occurs in the Sensor circuit 1
32(8)
F
S 11(1)
• the total resistance rises towards infinity Sensor 24(7)
34(9)
F
S
31(11)
21(6)
2
• if the value rises above the defined threshold (12 kOhm) A1(2)
A2(10)
• the relays are de-energised
M M
• the red LED illuminates
N
without uxillary with Auxillary
Contact Contact

~11 kOhm
Upper
Switching ESR-12
Resistance

Threshold
In addition to ESR-11
Sensor

Nominal
8.2 kOhm • Simple signal evaluation per output
Resistance

~6.2 kOhm F1
Lower
Switching
Threshold P
F2 F3
Signal Output
Relay Contacts 14(3)
Sensor 22(5) F 12(4)
32(8) S
1 11(1)
Sensor 24(7) F 31(11)
34(9) S
2 21(6)
A1(2)
A2(10)

Connection M M

• The maximum length of the Sensor with cable must not N


exceed 25 metres
• Maximum surface area 5 m 2
• Multiple Sensors are to be connected in series
• The total resistance must not exceed 8.2 kOhm

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 5
ESR-13 Technical data ESR-1
In addition to ESR-11
• Error indication connection Housing Type M3, Material Red Noryl
Isolation Class IP 30 (IEC 529)
Weight max. 250 gramm (depending
F1 on type)
P Power Supply DC voltages are battery power
F2 only
14(3)
Sensor 22(5) F 12(4) - Type ESR-1. -24VADC 24-36VAC/24-48VDC (±20%)
32(8) S
1 11(1)
24(7) 31(11)
- Type ESR-1. -115VAC (+10%/–20%) with isolating
Sensor F
34(9)
2 S
21(6) transformer
A1(2)
- Type ESR-1. -230VAC (+10%/–20%) with isolating
Error collecting

A2(10)

ESR-13: Error indication relay.


M transformer
Contacts open when error
Frequency Range 50/60 Hz (45–66 Hz)
loop

ESR-13M: Error indication relay.


Contacts closed when error
N
Error Power consumption max. 3 VA
indication
Duty Cycle 100% ED
Signal Output Relay/
Error Indication Relay
Dimension Sheet - Switching Capacity 250 VAC/5 A (ohm)
- Contact Material Hard silver
- Operating Life Mechanical 200 million
switchings
Electrical 80 000 switchings at
250 VAC/5 A
- Fuse Protection 5 A slow
74

Indicators LED 5 mm
- Operation Green
- Function Yellow
36 12 85
-Error Red
Reaction Time < 70 ms
Temperature Range
- Operation –20°C to +50°C
- Storage –20°C to +80°C
Humidity max. 80% relative

D53 002 E 06/05

6 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Switching Units

ESR25/26
• 11 Pin Plugable Socket
• GS-BE-17 and ZH 1/494
• 1-/2-Channel

General Connection
The difference between the ESR25 and ESR26 is that the • max. total length of sensor with cable 50 m
ESR26 has two separate evaluation circuits. • max. total area of sensor 5 m2
• multiple sensors are connected in series
• the total resistance must not exceed 8.2 kOhm
Function
Important: • The installed fuse is absolutely neccesary. It
Connected sensors are monitored with a terminating protects the relay contacts against «welding»
resistance of 8.2 kOhm to detect changes in the constant when overloaded.
flowing zero-signal current. Both relays are energised in • Suppressors (220 Ohms/0.1 µF) are to be
the non-active condition. connected across the connected loads.
• Periodical function test are to be made. The
If one or more sensors are activated designated test contacts are to be bridged (see
• the total resistance drops towards zero ohm Layout). The applied tests are to be docu-
• when the resistance falls below the defined limit (approx. mented.
2 kOhm) • Further installation instructions can be ob-
• the relays de-energise tained from the operators manual enclosed
• the yellow LED illuminates with the product.

When a fault occurs in the sensor circuit (cable breakage,


sensor defect…)
• the total resistance increases
• when the resistance exceeds the defined limit (approx.
9 kOhm)
• the relays de-energise
• the red LED illuminates

Terminal/Connections

Terminal ESR25 ESR26


A1,A2 (2,10) Supply 24VACDC Supply 24VACDC
22,32 (5,8) Sensor-Input Sensor-Input 1
24,34 (7,9) Sensor-Input (or 8.2 kOhm) Sensor-Input 2
11,21 (1,6) Safety-Output Safety-Output 1
12,14 (3,4) – Safety-Output 2
31 (11) – –

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 7
Block Diagram Technical Data
Housing NORYL, red
11(1)
Face Black
Sensor 22(5) Dimensions 85 x 74 x 36 mm
32(8)
1 R1
24(7)
Drive Plug-socket 11-Pin
Sensor Circuit
2
34(9) F1 Isolation Class IP30
R3
or 8.2kOhm resistance
21(6) Isolation Class IP54
Supply A1(2) Application area
Voltage A2(10)
Temperature Range –20°C +55°C
Power Supply 24 VACDC ±10%
Frequency 50/60 Hz
ESR25 Power Consumption
• two parallel sensor inputs - ESR25 < 3 VA
• safety output - ESR26 < 5 VA
• supply voltage 24VACDC Sensor Input ESR25
• redundant evaluation of the sensor - Reaction Value
«Activated» < 2.3–2.5 kOhm
- Reaction Value
«Interruption» > 8.9–10.4 kOhm
11(1) Sensor Input ESR26
22(5)
Sensor - Reaction Value
32(8)
1 R1
Drive «Activated» < 1.4–1.8 kOhm
Circuit 1
R3
F1 - Reaction Value
21(6) «Interruption» > 8.6–9.3 kOhm
24(7) 14(3) - Reaction Time max. 12 ms
Sensor 34(9)
2 R2 Drive Signal Output Relay 2 A/50 VAC per channel
Circuit 2 Display LED 3 mm
F2
R4
12(4) - Operation Green
Supply A1(2) - Safety Switch-off Yellow
Voltage A2(10) - Error (Interruption)
Red
Test Specifications GS-BE-17 (April ‘98) and
ZH 1/494
(Issue August 1994)
ESR26 Overvoltage Category II (EN 61010-1)
• two separate sensor inputs Contamination Grade 2 (EN 61010-1)
• two separate safety outputs Protection Class 0 (EN 60730-1 and EN 60335-1)
• supply voltage 24VACDC
• redundant evaluation of both channels

LED Status

Supply Voltage Function Green Yellow Red Output


Off Open
On Ready Close
On One sensor activated Open
On Short-circuit or Test Open
On Cable breakage Open

8 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Layout Dimension Sheet

ESR25

F1

74
REL1
J1 LED
REL3 4
J4
3
2
1 36 12 85

Ordering Information

ESR26
e.g. ESR25-24VACDC
F1
Type
REL1 J3 ESR25
J1 LED ESR26
REL3 4
J4
3 Supply Voltage
F2
2 24ACDC
REL2 J2 1
6
REL4 5

LED5 Operation Display (green)


LED6 Operation Display (green) (only ESR26)
LED1, LED2 Function Display (yellow)
LED3, LED4 Error Display (red)
REL1, REL3 Switching Circuit 1, Working contact
switched in series
REL2, REL4 Switching Circuit 2, Working contact
switched in series (only ESR26)
F1 Fuse 2 Amp slow Relay contact protection
F2 Fuse 2 Amp slow Relay contact protection
(only ESR26)
J1 Test Contact for REL1
J2 Test Contact for REL4 (only ESR26)
J3 Test Contact for REL2 (only ESR26)
J4 Test Contact for REL3
D53 003 E 06/05

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 9
Switching Unit

ESA 25 (A = Installation Housing)

ESP 25 (P = Printed Circuit Board)

• IP65 Protection Class (ESA 25)


• Installation Housing
• Redundant signal evaluation

Switching Units ESA ESAS 25, ESPS 25 / Stop-Restart


• Basic function as ESA 25/ESP 25
Connected Sensors are monitored for changes in the con- • Additional when the Sensor is activated for 1 sec.
tinously flowing no-load current. the third relay contact closes for 1.5 sec. (restart)
In the non-activated condition both relays are energised.

ESA 25, ESP 25


Sensor
When one or more Sensors are activated
• the total resistance sinks towards zero ohm Safety Contact
• if the value falls below the defined threshold Restart
~1s ~1.5s
• the relays are de-energised
• the yellow LED illuminates

1 3
Wiring Diagram Sensor
2
Safety
For each sensor two redundant channels are available. The Circuit
two output contacts are connected in series and protected
with a fuse. 4

3
Sensor
1 τ Restart
2 8
Drice
Circuit
5 ~
Supply =
6
4

ESAS 25 / ESPS 25
5 ~
Supply =
6

ESA 25 / ESP 25

10 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
ESAT 25, ESPT 25 / Service Door Technical data
• Basic function as ESA 25/ESP 25
ESA 25 ESP 25
• Additional input for service door function
Housing ABS grey –
• Output for ermergency stop circuit
transparent cover –
Dimensions 80 x 110 x 65 70 x 94
1 3
Sensor - Protection Class IP65 IP00
2
Safety - Cable gland 3 x PG9 –
Circuit Supply Voltage 230 VAC (+10/–20%)
with isolating trafo
4
115 VAC (+10/–20%)
7 with isolating trafo
τ Restart
8 24 VADC (+10/–10%)
Frequency Range 50/60 Hz
11
Service 9 Emergency Power Consumption max. 4 VA
Door 10 Stop Circuit Sensor Inputs
12
5
- Input resistance 5 kOhm to 12 V (internally)
Supply ~
6 = - Input voltage with
8.2kOhm approx. 7.5 VDC
ESAT 25 / ESPT 25 Signal Output Relay
- Switching Capacity 2 A/250 VAC
- Reaction time < 15 ms
Connection
- Reaction time
• The maximum length of the Sensor must not exceed by interrupt < 15 ms
50 metres Indicators LED 3 mm
• Maximum surface area 5 m2 - Operation Green
• Multiple Sensors are to be connected in series - Safety Shutdown Yellow (2 off)
• The total resistance must not exceed 8.2 kOhm - Error (interrupt) Red (2 off)
Temperature Range –20°C to 55°C
Important: Testing Basis GS-BE 17 and ZH 1/494
• the installed fuse is absolutely necessary
- to protect the relay contacts from «welding» when Additional Data
overloaded
Function «Restart» ESA 25 ESP 25
• Suppressors (Type 220 Ohm/0.1 µF) are to be connected
Housing see ESA
across inductive loads
Cable Gland 1 x PG7, 3xPG9 –
Relay fro Restart Function
The assembly and operating instructions are
- Switching Capacity 2A/250VAC
described in the Assembly and Operating
- Time Delay 1…1.5sec
Manuals supplied with the product.
- Impulse Time 1.5…2sec

Function «Servece Door» ESAT25 ESPT25


Housing PVC grey
- Dimensions 105 x 105 x 66 94 x 94 x 32
- Protection Class IP55 IP00
- Cable Gland 4 x PG7, 1xPG9 –
Relay for Service Door
- Switching Capacity 2A/250 VAC

Status LED

Supply Function Green Yellow Red Output


Off Not ready open
On Ready closed
On Sensor activated open
On Short-circuit or test open
On Cable breakage open

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 11
Dimension Sheets Print Version
Installation Housing
LED2 LED3
J1 LED4 LED5
110 65
1.5

=
90 J2
LED1
TR1
¢4.4

70
REL2 REL1
12
80
60

=
F1

56
3 4
75
94

PG7 PG7 PG9 ESA/ESP

ESA 25 Terminals/Connection Layout:


3,4 Safety Circuit – 5,6 Supply – 1,2 Sensor
110 65
90 1.5
LED2 LED3
J1
¢4.4

LED4 LED5

=
J2
LED1
80
60

TR1

70
REL2 REL1
1 2 REL3

=
F1

56
78 3 4
PG7 PG9
75
ESAS 25 94

105 5 61 ESAS/ESPS

Terminals/Connection Layout:
3,4 Safety Circuit – 7,8 Restart – 5,6 Supply – 1,2 Sensor
20
65.5
105

LED2 LED3
J1
LED4 LED5
J2
=

LED1
TR1
REL3 REL2 REL1
94

4xPG7 PG9
F1

ESAT 25 1 2 9 10 REL4
=

11 12 7 8 3 4 56

Connections, Component Layout


80
LED1 Operating indicator (green) 94

LED2, LED4 Function indicator (yellow)


LED3, LED5 Error indicator (red) ESAS/ESPS
REL1, REL2 Switching circuit, working contacts
switched in series Terminals/Connection Layout:
F1 Fuse 2A slow, relay contact protection 3,4 Safety Circuit – 7,8 Restart – 5,6 Supply – 1,2 Sensor
J1 Test contact for REL1 – 9,10 Input Service Door – 11,12 Output Service Door
J2 Test contact for REL2

12 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Overview ESA/ESP

DOOR
Total SERVICE

Programme
OPEN

ESA 25
ESA 25-R
ESA 25-D
ESAS 25
ESAS 25-R
ESAS 25-D
ESAT 25
ESAT 25-R
ESAT 25-D
ESP 25
ESP 25-R
ESP 25-D
ESPS 25
ESPS 25-R
ESPS 25-D
ESPT 25
ESPT 25-R
ESPT 25-D
ESZ-25
ESZ-25.D
ESZS-25
ESZS-25-D

Order Information

e. g. ESPT 25-230 AC

Type
ESA Standard Unit
ESP Standard Print Version
ESAS Stop-Restart
ESPS Stop-Restart Print Version
ESAT Service Door
ESPT Service Door Print Version
ESZ plugable

Supply Voltage
24VADC
115VAC
D53 004 E 06/05

230VAC

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 13
Switching Units

ESQ
• GS-BE17 and ZH 1/494
• 4-channel
• Housing IP65
• Redundant evaluation

Connection
• max. total length of one sensor system with cable 50 m
• max. total area of one sensor system 5 m2
General
• multiple sensors are connected in series
The ESQ is a electronic switching unit of the ES family. It • the total resistance must not exceed 8.2 kOhm
controls sensors to a zero-signal current.
Important
• the installed fuse is absolutely necessary. It protects the
Function relay contacts against «welding» when overloaded.
Connected sensors are monitored with a terminating resi- • Suppressors (220 Ohms/0.1 µF) are to be connected
stance of 8.2 kOhm to detect changes in the constant flow- across the inductive loads.
ing zero-signal current. All relays are energised in the non • Periodical function tests are to be made (see Assembly,
active condition. Commissioning, Periodical Tests)

If one or more sensors are activated


• the total resistance of the sensor system drops towards ze-
ro ohm
• the resistance falls below the defined limit (1.5 kOhm)
• the safety relay de-energises
• the appropriate service relay de-energises (no safety
output)
• the yellow LED illuminates according to the illustration
«Status LED»

When a fault occurs in a sensor circuite (cable breakage,


sensor defect…)

• the total resistance of the appropriate sensor system in-


creases
• the resistance exceeds the defined limit (9 kOhm)
• the safety relay de-energises
• the appropriate service relay de-energises (no safety
output)
• the red LED illuminates according to the illustration
«Status LED»

14 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Status LED

safety edges service safety


1 2 3 4 1 2 3 4 6 7 8 9 11 12 13 14 16 17 18 19 5 10 15 20 21 22 1 2 3 4

safety edges LED


ready red on outputs:
(relays)
activated yellow on closed

cable breakage off open

Terminal/Connections

1,2 Sensor-Input 1
3,4 Sensor-Input 2
5,6 Sensor-Input 3
7,8 Sensor-Input 4
9,10 Supply 24VACDC
11,12 Service-Output1
13,14 Service-Output 2
15,16 Service-Output 3
17,18 Service-Output 4
19,20 Safety-Output

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 15
Block Diagram Tecnical Data

1
11 Housing ABS, gray, cover
transparent
2
12 Dimensions 120 x 200 x 75 mm
Isolation Class IP65
Temperature Range –20°C to 55°C
13
3 Power Supply 24 VACDC ±10%
4
Frequency 50/60 Hz
14 Power Consumption < 6 VA
Reaction Time max. 15 ms
15
Signal Output Relay
5
- Safety 2 A/250 VAC
6 - Service 2A/250VAC per channel
16
Display LED 3 mm
- Operation green
7
17 - Safety Switch-off yellow (2 for status relay)
- Error (Interruption) red (2 per channel)
8
18 - Service yellow (2 per channel)
19
Overvoltage II (EN 61010-1)
1
Contamination Grade 2 (EN 61010-1)
2AT Test Specifications GS-BE-17 (Aug. 94)
and ZH 1/494
1 Protection Class 0 (EN 60730-1 and EN
20
60335)
9 7812 7812
RED
YELLOW
10

• four parallel sensor inputs


• one safety output
• four service outputs
• supply 24VACDC
• redundant evaluation of sensors

16 Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12
Layout Dimension Sheet

9 LED1
J1 LED5
10 LED2 REL 1 11
LED3
LED23 J2 12
LED4
13
LED6 LED10 REL 2 14
J3

120
90
LED7
LED8
J4
LED9 LED21 REL 5 19
100
90

1
LED11 20
2 J5 LED22
LED12 REL 6
3 F1
LED13
4 J6 188,3
LED14 LED15 15 200
5 REL 3 16
LED16 75
6 J7
LED17 17
7
LED18 LED20 REL 4 18
8 J8
LED19

138,2
160

red
yellow

LED2, 4, 7, 9, 12, 14, 17, 19 Function sensor (yellow)


LED1, 3, 6, 8, 11, 13, 16, 18 Error (red)
LED5, 10, 15, 20 Function display relay
Service (yellow)
LED21, 22 Function display relay
Safety (yellow)
LED23 Operation display (green)
REL1, 2, 3, 4 Service
REL5, 6 Safety
F1 Fuse 2Amp slow, Order Information
Relay contact protection
J1, 3, 5, 7 Test contact for
REL1, 2, 3, 4 and REL5 ESQ25-24VACDC
J2, 4, 6, 8 Test contact for REL6

D53 005 E 06/05

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, Switzerland, Phone +41 (0)52 687 11 11, Fax +41 (0)52 687 11 12 17