PRODUCT SPECIFICATIONS:

BRAND:
ORIGIN:
REFERENCE:
ANALYTICAL METHOD: Non-dispersive infrared "NDIR", original technology from
Germany.
MODE OF OPERATION: Continuous, extraction of gases from the chimney by high
performance vacuum pump. cotton filter as agent for moisture absorption and
retention of particulate material attached to a condensate separator; The system is
commanded by last generation microcontrollers + PLC HMI, integrated into a set of
electrical, electrical, mechanical and pneumatic parts to offer a reliable, safe, continuous
operation with low maintenance costs.

The design of the Continuous Emissions Monitor and the integrated functions allows
compliance with the requirements of environmental standard 909 and the Protocol for
the Control and Monitoring of Atmospheric Pollution Generated by Fixed Sources of the
Ministry of the Environment.

OUTSTANDING CHARACTERISTICS AND REGULATORY COMPLIANCE


 Record of result: every 5 minutes. Fully automatic operation
 Maximum reading in CARBON MONOXIDE: 2000 mg / m3. Excess emissions do
not cause deterioration.
 Reading of residual oxygen in the chimney: zirconium cell, real-time analysis, automatic
calibration.
 Reading and continuous recording of gas temperature. (Article 86 and 88, res
909 MAVDT); Page 52-53 of the Protocol.
 Data memory: Cyclic exceeding 10,000 complete data, including the clock -
calendar data.
 Delivery of results: 4.3 "screen, HMI (human machine interface), full color, as a
punctual result.
 Obtains results in PC, external laptop type without the need of online operation
and results are obtained compensated to reference conditions as specified in
resolution 909 article 86: "Correction to reference conditions"; article 88
"Compensation to 11% of oxygen", analyzing the actual oxygen content in the
chimney; results in GEOMETRIC hours and daily averages.
 Construction in plastic chest- Legrand fiberglass marine use (France), IP65
protection; direct jet and corrosion, measures 80 x 60 x 28 cm, weight 40 kls.
 Pneumatic ball valves in 304 stainless steel, motorized drive; free of
deterioration due to acidity, humidity and contamination.
 In the chimney it is installed: suction probe and thermocouple temperature.
 Eva Automatic condensate evacuation after each reading.
 Automatic condensate evacuation after each reading.
 Robust, long service life, low maintenance cost, technical service and direct
factory replacement
 Future option of annexing in its operation the analysis of a second furnace
located in the same machine room.

WARRANTY:
The instruments are delivered with a guarantee on their operation and / or
manufacturing defects for the term of one year from the day of entry into operation;
This warranty does NOT cover the consumable supplies listed below or within the
specified usage period:
 Filters.
 Gas transport hoses.
 Affectation of the parts not attended in a timely manner in the inspection
routines given at the time of commissioning.
 Calibration certificate valid for (12) months.

 The detector and the infrared emitter are protected with glass windows CaF2 -
calcium fluoride -; that prevent gases from affecting or deteriorating elements of
high technical incidence and representative cost by isolating themselves from the
transit of gases; As they are detectors of solid state elements, they can eventually
have a lifespan of more than 10 years, without considering external and external
causes such as lightning-type atmospheric discharges or other uncontrollable
environmental causes.
 The manufacturer guarantees the supply of spare parts in a timely manner;
guarantee the stock of standard gases for the calibration and certification service.
The irresponsible intervention or manipulation of external persons not authorized
by the manufacturer to the instruments entails the loss of the guarantee.
 review the attached regulations and capture the requirements related to crematoria
and incinerator ovens there and translate them.

OPERATING CONDITIONS AND REQUIREMENTS OF THE APPLICATION

Parameter in the Sampling point Valor


Measurement CO (0-2000 ppm) y O2 (0 -25%)
Place of assembly Indoors
Distance from the point of view to the system <= 15 metros
Room temperature 5 a 35°C
Gas temperature at sampling point 280,00 °C
Gas Pressure -150 a -5 mbar (g)
Powder content (sum of all solids) <= 30 mg/m3
Moisture content Dew Point <= 70°C, <= 30% Vol
Power 120 VAC, 60 Hz
Gas Composition CO 5 a 2000 mg/m3
O2 10 a 21% Vol
CO2 2 a 15% Vol
H2O <= 30% Vol
Remnant Nitrogen
The recording of the results must be done every 5 minutes. Include HMI with programming for
correction of results to reference conditions (Article 86 of the standard) with compensation to
11% of Oxygen (Article 88)
The cabinet should preferably be plastic (lower cost) IP65 and the condensate drain should be
automatic.

the standard requires in the case of crematoria, the continuous monitoring of CO and O2.
They burn natural gas or propane and corpses. The exhaust pipe of the gases has a diameter
of 450 to 500 mm, with a minimum height of 15 meters. The analyzer socket will be installed
12 meters above ground level.
The temperature of the emission gases according to the norm can not be higher than 250 ° C
but the probe has tolerance to 300 ° C. In addition, the humidity must be handled with the air
conditioning system, since before the gas is released from the chimney it is cooled with water
(showers, atomized water in direct contact to avoid the transformation of dioxins using dry
steam) and the Temperature at that point can be of the order of 800 ° C.
Each oven has 4 burners per standard that are directed to a single fireplace. The real
opportunity is the sale of 3 ovens for the same customer. The monitoring and control of O2 and
CO must be registered for the presentation of fines to regulatory entities when necessary.
They must be registered (basic option) and controlled (additional option).
What is the most basic and economic thing that could be offered for this type of application?