BRAND:
ORIGIN:
REFERENCE:
ANALYTICAL METHOD: Non-dispersive infrared "NDIR", original technology from
Germany.
MODE OF OPERATION: Continuous, extraction of gases from the chimney by high
performance vacuum pump. cotton filter as agent for moisture absorption and
retention of particulate material attached to a condensate separator; The system is
commanded by last generation microcontrollers + PLC HMI, integrated into a set of
electrical, electrical, mechanical and pneumatic parts to offer a reliable, safe, continuous
operation with low maintenance costs.
The design of the Continuous Emissions Monitor and the integrated functions allows
compliance with the requirements of environmental standard 909 and the Protocol for
the Control and Monitoring of Atmospheric Pollution Generated by Fixed Sources of the
Ministry of the Environment.
WARRANTY:
The instruments are delivered with a guarantee on their operation and / or
manufacturing defects for the term of one year from the day of entry into operation;
This warranty does NOT cover the consumable supplies listed below or within the
specified usage period:
Filters.
Gas transport hoses.
Affectation of the parts not attended in a timely manner in the inspection
routines given at the time of commissioning.
Calibration certificate valid for (12) months.
The detector and the infrared emitter are protected with glass windows CaF2 -
calcium fluoride -; that prevent gases from affecting or deteriorating elements of
high technical incidence and representative cost by isolating themselves from the
transit of gases; As they are detectors of solid state elements, they can eventually
have a lifespan of more than 10 years, without considering external and external
causes such as lightning-type atmospheric discharges or other uncontrollable
environmental causes.
The manufacturer guarantees the supply of spare parts in a timely manner;
guarantee the stock of standard gases for the calibration and certification service.
The irresponsible intervention or manipulation of external persons not authorized
by the manufacturer to the instruments entails the loss of the guarantee.
review the attached regulations and capture the requirements related to crematoria
and incinerator ovens there and translate them.
the standard requires in the case of crematoria, the continuous monitoring of CO and O2.
They burn natural gas or propane and corpses. The exhaust pipe of the gases has a diameter
of 450 to 500 mm, with a minimum height of 15 meters. The analyzer socket will be installed
12 meters above ground level.
The temperature of the emission gases according to the norm can not be higher than 250 ° C
but the probe has tolerance to 300 ° C. In addition, the humidity must be handled with the air
conditioning system, since before the gas is released from the chimney it is cooled with water
(showers, atomized water in direct contact to avoid the transformation of dioxins using dry
steam) and the Temperature at that point can be of the order of 800 ° C.
Each oven has 4 burners per standard that are directed to a single fireplace. The real
opportunity is the sale of 3 ovens for the same customer. The monitoring and control of O2 and
CO must be registered for the presentation of fines to regulatory entities when necessary.
They must be registered (basic option) and controlled (additional option).
What is the most basic and economic thing that could be offered for this type of application?