This valve provides a momentary (pulse) output at its cylinder port when pressure is applied at its inlet. No additional flow is
possible until pressure at the inlet is removed, reset time allowed, and pressure reapplied. Reset time is slightly longer than output
pulse time.
Features
• One moving part. • Spool action can be
• Buna-N seals. observed for trouble
• Pulse time preset shooting circuit.
at factory. • Operating pressure:
OS-1 (See Model Chart) 45 to 150 psi.
• Shorter pulse can be • Operating temperature:
Operation field set with ordinary 0° to + 180°F.
When the incoming signal sewing needle. • No springs.
is applied to the IN port, the • Can be cleaned or • Self-cleaning orifice.
spool is immediately shifted, repaired without
allowing the pressure to and removing from installation.
through the CYL port,
becoming the output signal. Applications
Pressure then bleeds across an orifice
through the piston head. When pressure is equal • Signal Conversion - Pulse, to convert a constant or maintained
on both sides of the piston head there is a force unbalance signal from a limit valve or other source to a pulse or momentary
on the spool. This force unbalance returns the spool to its original signal for a double piloted valve or other device. This allows the
position. In this position the incoming signal is blocked and the double piloted valve to be shifted back even though the originating
CYL is connected to the EXH, in turn venting the output signal. limit valve is still held open. See sequencing circuit on page 13.4.
Before the valve can produce another output signal it must
be reset. This is accomplished when the input signal is removed • Single Cycle, to convert a signal from a hand or foot control
from the IN port and the pressure behind the piston bleeds back to a pulse signal. This allows only one cycle of the circuit even
through the orifice and drops to zero psi. This also self cleans the if the operator holds the starting device on. The operator must
orifice every cycle. The next incoming signal can then produce release the starting device to reset the one-shot / pulse valve and
another output signal. then reactuate to achieve the next cycle. See pressure sensing
NOTE! The incoming signal MUST be of sufficient pressure circuit on page 13.4.
and volume to shift the spool before bleeding across the orifice
and balancing out. • Open End Blast, to provide a pulse of air through a nozzle or
tube for automatic part blow off or chip removal.
IN EXH
Sizing Symbol
Approximate Approximate
Model Pulse Time, ResetTime, Weight
Seconds Seconds
Number @80 psi @80 psi Port Size Oz.
OS-1 3/4 1 1/8 NPT 3.1
OS-3 1-1/2 2 1/8 NPT 4.8
CYL
Dimensions Materials:
Body, Aluminum, Unanodized
Model No. OS-1 & OS-3 1/8 NPT Ports Cap, Brass
Spool, Aluminum IN
.97
.28
13
1/8 NPT Ports EX
1.25
.16
.75 .44
2 Mounting Holes .78
for #10 Screws 1.56
2.31 OS-1
3.81 OS-3
Dimensions Symbol
IN
2 Mounting Holes for #10 Screws
1/2 Hex
.25 .56 Maximum
13 1.75
Vent
1. Start signal to V1
2. C1 - extends to load Start Signal
3. Load pressure from C1 to V2
4. Constant signal from V2 to V3 V1
Gauge 4 Way
5. Pulse signal from V3 to V4 C1
Control Cylinder
6. C2 extends to load Valve
7. Load pressure from C2 to V5 IN
V2
8. Signal from V5 to V4 Pressure Flow
9. C2 retracts to V6 Sensing/ Control
10. Constant signal from V6 to V7 Sequence Valves CYL
Valve Vent
11. Pulse signal from V7 to V1 V7
OUT One Shot
12. C1 retracts (Pulse)
EXH IN Valve
EXH IN
Time Delay Circuit Supply
Check Valves
Features Options
• Machined brass bar stock • Viton® O-Ring Seals
• Brass poppet (-15° to +400° F); Specify Suffix -V
• Buna-N O'Ring seals (–30° to +250° F)
• Available with or without spring
• Operating pressure: 150 psi max.
Shuttle Valves
Features Options
• Machined brass bar stock • Viton® O-Ring Seals
• Light weight Delrin® poppet (for media compatibility); Specify Suffix -V
• Operating temperature: (0° to +180° F)
• Buna-N O'Ring seals
• Operating pressure: 10 to 150 psi
1.13
.75 1/8 NPT
#10-32 Ports Ports
1/8 NPT
#10-32