Case considered for design - Inner tank full, Outer tank empty (Most critical)
1. Design Constants
σcbc (Mpa) 7 IS 456 - Annex B Table 21
k 0.384 m x σcbc / ( ( m x σcbc ) + σst )
Modular ratio m 13.333 ( 280 / ( 3 x σcbc )
j 0.872 1-(k/3)
2. Permissible Stresses
σst (Mpa) 150 IS 3370 Part 2 - Table 2
Tension Concrete σct (Mpa) 1.2 IS 3370 Part 2 - Table 1
Tension steel σs (Mpa) 150 IS 3370 Part 2 - Table 2
3. Design Data
D Internal Ø (m) 5.25
H Internal Ht. (m) 4.3
Hoop tension T (kN) T
124.163
= wHD/2
Assume wall thk. (mm) 200.00
6. Distribution steel
Min. Steel (%) 0.217 IS 3370 Part 2 - Cl. 7.1
Ast (mm2) 434.29
Bar Diameter (mm) 8 Ast (To be provided vertically)
Spacing on both faces (mm C/C) 200
7. Base slab
Base slab thk. (mm) 200
Min. Steel (%) 0.217 IS 3370 Part 2 - Cl. 7.1
Ast (mm2) 434.28571
Bar Diameter (mm) 8 Ast (To be provided both ways & both
Spacing top & bottom, bothways faces) Spacing provided = 150 mm C/C
200