Sie sind auf Seite 1von 2

Crane operation malfunctions

15.4 Trouble shooting and rectification at the power units

Displayed error codes


Error code display has three areas:
– Area 1 has two displays with four digits each
– Area 2 has a display with four digits
– Area 3 has a display with four digits
Only 0 and 1 are always displayed.

The following table shows some of the error codes, their cause and if pos-
sible, their remedy.

Error code in area 1


Displayed code Error/effect Remedy
number
00000001 Error on proximity switch
for locking system/dis-
play Current locking status
display no longer Telescoping with the
functions properly emergency program; à
Sub-menu emergency pro-
00000010 Error on proximity switch gram telescoping,
for locking system/Tele- p. 15 - 108.
scoping cylinder at the lock-
ing point display no longer
functions properly
00000100 Error on locking system Notify GROVE Customer
on the telescoping cylin- Support, if required re-
der head/locking and un- tract the main boom us-
locking cannot be moved ing the mechanical
any more emergency stop;
à p. 15 - 92.
00001000 Length indicator for tele- Telescoping with the
scoping cylinder defec- emergency program, call
tive/display Extended up the extended lengths
length of the telescoping cyl- of the telescoping cylin-
inder not functioning ders on the SLI, if neces-
sary; à Sub-menu
emergency program telescop-
ing, p. 15 - 108.

s
18.10.2002

Operating instructions GMK 7450 2 084 734 en 15 - 33


Crane operation malfunctions
15.4 Trouble shooting and rectification at the power units

00010000 The length indicator of Check as to which length


crane control and that of should not be present. For
the SLI record different example record telescop-
values for the extended ing outside and compare
length of telescoping cyl- corresponding length de-
inder tails in Table for approach-
ing locking points
(à p. 15 - 117) with dis-
plays Enter the current
telescoping if required;
à p. 15 - 119
00100000 Logical error in Telescoping with the
the sequence/e.g. display emergency program; à
for the length of telescop- Sub-menu emergency pro-
ing cylinder becomes gram telescoping,
smaller when extending p. 15 - 108.
Notify GROVE Customer
Support
01000000 Signals received on lock- Telescoping with the
ing status are not realistic emergency program; à
/ e.g. a damaged proximi- Sub-menu emergency pro-
ty switch gram telescoping,
p. 15 - 108.
10000000 Fault at the mechanical in- Notify GROVE Customer
terlock, a valve is stuck or Support.
something similar

Error code in area 2


0001 Control unit connection 1 Replacing control units;
failed/telescoping gear à Connections for the
deactivated crane control's control
units., p. 15 - 83.

0010 Failure of the I/O board 6 Notify GROVE Customer


Support

Error code in area 3


0001 Power supply not avail- Notify GROVE Customer
able for the control unit 0. Support
0010 Power supply not avail- Notify GROVE Customer
able for the length indica- Support
tor.
0100
Notify GROVE Customer Support
1000
18.10.2002

15 - 34 2 084 734 en Operating instructions GMK 7450