Sie sind auf Seite 1von 8

Point of view

How the Water-


Cement Ratio Affects
Concrete Strength
BY PIERRE-CLAUDE AÏTCIN AND ADAM NEVILLE

T his is not just another paper on the water-cement


ratio (w/c): it goes beyond the well-known relation
between w/c and strength and tries to get behind that
concrete; and ƒ′c is the compressive strength of mortar
determined on test specimens of specific shape and size
at a specific age. Féret found that a power of 2 gave the
relation. In other words, our intention is to try to find out best fit and determined the value of the coefficient k by
whether the influence of the w/c on strength arises experiment.
simply from the fact that a part of the mixing water Still working in terms of volumetric proportions, by
produces voids that weaken the mass of hydrated introducing the term W/C, we can rewrite Eq. (1) as
cement paste or whether there are other, possibly more
fundamental, factors involved. To resolve the problem, ƒ′c = k / [1 + W/C + A/C]2 (2)
we have to consider not only the hydrated cement paste
but also mortar or concrete containing this cement It may be thought unusual to deal in terms of volumetric
paste. In this connection, it is useful to look into the proportions, but this is the only scientifically sound
relation between the strength of mortar and of concrete, approach. The volumetric proportions of the relevant
both containing the same cement paste. To start with ingredients in 1 m3 of concrete are typically: C = 0.1, A = 0.01
what is well-known, we shall first consider the early to 0.02, and W = 0.2. Thus, W/C = 2 and A/C = 0.1. We can,
studies on the w/c. therefore, neglect the term A/C and rewrite Eq. (2) as

RELATION BETWEEN STRENGTH AND M /? ƒ′c = k / [1 + W/C]2 (3)


For the sake of brevity, the term “strength” will be
used to mean compressive strength. Probably the first Given that in reality concrete is batched not by
formulation of the relation between strength and the volume but by mass (possibly with the exception of
nonsolid ingredients of concrete was made by Féret in water), and that engineers usually work in terms of
France in 1892.1 He understood the fact that the presence mass proportions, with c and w representing the mass
of water- and air-filled space in mortar has a negative of cement and water, respectively, in a unit volume of
influence on strength, and from his experimental work, concrete, we can write Eq. (3) as
established a power relation
ƒ′c = k / [1 + 3.15 w/c]2 (4)
2 2
ƒ′c = k C / (C + W + A) (1)
This equation recognizes the fact that the specific
where C, W, and A each represent the volume of cement, gravity of water is 1, the typical specific gravity of
water, and entrapped air respectively, in a unit volume of portland cement is 3.15, and uses the universal term for
the water-cement ratio by mass, w/c.
This point of view article is presented for reader interest by the A relation between strength and the W/C was developed,
editors. However, the opinions expressed are not necessarily those probably independently, by Abrams2 in the United States
of the American Concrete Institute. Reader comment is invited.
ƒ′c = A/BW/C (5)

Concrete international / AUGUST 2003 51


where W/C is expressed by volume, and A and B are water involved in the hydration of cement and
constants dependent on the specific conditions such as about the volumes of cement, water, and products
the cement used, curing, and age at test. of hydration. The findings of Powers are valid to
The work of Féret and of Abrams represents a this day, but surprisingly, some engineers are still
significant contribution to the understanding and, not entirely clear about the water used up in the
above all, use of concrete, and for that they deserve hydration of cement and the water necessary for
considerable credit. The cements they used, however, the hydration to proceed.
were very different from modern cements and, even The source of confusion lies in the fact that the water
more importantly, modern concretes usually contain required to fully hydrate 1 gram of C3S or C2S is about
additional ingredients. Their cements were much more 0.22 gram. The volume of products of hydration of
coarsely ground than modern cements, and their portland cement, however, is larger than the sum of the
chemical compositions were different. Moreover, Féret volumes of the cement and water participating in the
and Abrams used no plasticizing admixtures—indeed reaction. Specifically, hydrated cement paste contains
no admixtures at all. Thus, the initial reactivity of their about 30% of very fine pores, known as gel pores.The gel
cements was low, so that the workability of concrete pores must remain filled with water.
was almost solely governed by the water content in It follows that a mixture with a w/c of 0.22 cannot
the mixture. hydrate fully. Indeed, a w/c of not less than about 0.42 is
As always, the concrete used by Féret and Abrams necessary for full hydration to be possible. This arises
had to have an adequate workability to achieve reasonably from the fact that it requires a volume of 1.2 mL to
full compaction. The absolute need for adequate accommodate the products of hydration of 1 mL of
workability must never be forgotten by those who anhydrous cement. In other words, the minimum W/C by
proportion concrete mixtures in the laboratory. volume for complete hydration is 1.2. This is equivalent
Because cement was an expensive ingredient, the to a w/c of about 0.42 by mass.
cement content in the mixtures used was relatively To put it another way, the minimum mass of water
low, so that a high water content entailed a high w/c. necessary for full hydration is twice the mass required
Typical values used by Féret and Abrams were between stoichiometrically for the formation of calcium silicate
0.6 and 1.0 by mass. A visual appreciation of the hydrates. A further complication arises from the fact
difference in the spacing of cement particles at a w/c that the water in the gel pores, which is adsorbed on the
of 0.65 and of 0.25 can be obtained from Fig. 1. surface of the gel, has a higher density than free water,
namely, about 1.1.
WATER REQUIREMENT FOR HYDRATION Some engineers are bothered that using a w/c lower
Early in the 20th century, the knowledge of cement than 0.42 means that some cement will always remain
hydration was largely that established by Le Chatelier, unhydrated; others are unhappy that at a w/c of 0.42, or
and it was only in the middle of that century that Powers higher, some capillary space is always present in the
and his co-workers established quantitative data about hydrated cement paste.
These issues are discussed in Properties of Concrete3
but seemingly the need for better understanding continues.
As recently as May 2002, an article on this topic was
published by Mather and Hime,4 but a fuller discussion
here may be beneficial. First of all, the figures given in
this article are only approximate, and they do not
recognize the fact that the different compounds in
clinker result in different products of hydration, with
varying amounts of chemically bound water. The size of
cement grains, that is, the fineness of cement, also
influences the rate of hydration, as well as the degree of
hydration, achieved in practice. It is worth repeating
that the cements used by Féret and Abrams were very
much coarser than modern cements.
As for some part of the original cement grains remaining
unhydrated, it should be pointed out that these remnants
are by no means harmful. Indeed, they can be considered
as very fine aggregate, admittedly much more expensive
Fig. 1: Diagrammatic representation of fresh cement paste with a
w/c of 0.65 and 0.25. The ratio of the areas of water and cement than conventional aggregate, but with the benefit of
is equal to the W/C by volume excellent bond to the products of hydration.

52 AUGUST 2003 / Concrete international


WATER REQUIREMENT OF CONCRETE
Considering further the concretes in the era of Féret
and Abrams, we should note that in the absence of any
plasticizing admixtures, they required a w/c much higher
than 0.42 or W/C much higher than 1.3. We can, therefore,
subdivide in Eq. (3) the term W/C into two parts: Wh /C,
where Wh represents the water required for full hydration
to be possible; and Wp /C, where Wp represents the
additional water for an adequate workability, which
could be called “workability water.” We can, therefore
write Eq. [3] as

ƒ′c = k / [1 + (Wh + Wp )/C] 2 (6)

Considering Wh /C = 0.42 ×3.15 = 1.32, we obtain

ƒ′c = k / [2.32 + Wp /C]2 (7)

which, in terms of mass proportions, and with a different


coefficient k′, is

ƒ′c = k′ / [0.74 + wp /c]2 (8)

By separating out the water that takes no part in


the formation of the hydrated cement paste, either
by being chemically combined or adsorbed, Eq. (7)
links the strength of concrete to the porosity of the Fig. 2: Relation between porosity and relative strength of
gross volume of hydrated cement paste. Thus, Eq. (7) various materials3
represents the relation between the compressive
strength of concrete and the porosity of the hydrated MIXTURES CONTAINING SILICA FUME
cement paste. This lies at the root of the “water- As far as hydrated cement paste is concerned, we
cement ratio rule” that engineers have been using for have considered portland cement only. Rao7 conducted
three-quarters of a century. Explicit reference to experiments on mortars with different contents of silica
porosity as a factor governing strength was made by fume and reported that their compressive strengths at
Sandstedt, Ledbetter, and Gallaway in 1973.5 different ages did not follow the classical expression
The influence of porosity of hydrated cement paste on relating strength to w/c. We find this observation not
strength accords with the known increase in strength as surprising because the chemical reactions of silica fume
hydration progresses and, because continuing hydration do not progress at the same rate as the reactions of
results in a greater volume of solids than that originally portland cement. In consequence, at very early ages,
occupied by the hitherto unhydrated part of cement, the silica fume can be considered as an inert, very fine
progress of hydration results in a decreased porosity. material, and not as a binder.
A further observation on the influence of porosity on The situation is complicated, however, because of the
strength is provided by the effect of air entrainment on physical effects of silica fume in that it affects the
strength. It is well known that, at a constant w/c, every packing of particles and, therefore, the forces controlling
1% of air in concrete reduces its strength by about 5%. the proximity of cement particles to one another at the
Such a relation is not unique to concrete. This beginning of the hydration process. Moreover, the very
was pointed out in 1981by Neville in the 3rd Edition of fine particles of silica fume act as nucleation sites for the
Properties of Concrete, where it is shown that the hydration of cement.
same curve represented the relationship between Furthermore, the chemical role of silica fume in the
the relative strength and porosity for materials as process of hydration is governed by the availability of
diverse as concrete, iron, stainless steel, plaster of Ca(OH)2, derived from the hydration of C3S and C2S in
paris, sintered alumina, and zirconia; the 4th Edition portland cement. It follows that, above a certain threshold
substantially repeats the material 3 (Fig. 2). Aïtcin in the binder, silica fume cannot undergo a significant
also developed these concepts in his book published amount of chemical reaction, so that the “excess” silica
in 1998. 6 fume is more truly an inert filler rather than a binder.

Concrete international / AUGUST 2003 53


FACTORS OTHER THAN 9 /+ away. The zone near the interface paste-aggregate is
The discussion so far, which translates W/C into called the transition zone or interface zone. The
porosity, justifies the “water-cement ratio rule,” but it hydrated cement there has been formed by the
does not explain entirely the underlying physical situation. process of solution of the cement compounds and
In any case, it should be pointed out that it is only pores subsequent precipitation; such hydrated cement is
above a certain minimum size that influence strength, so sometimes referred to as external hydration products.
that the pore size distribution also enters the picture. It On the other hand, away from the interface zone,
is intuitively understandable that more voids mean a hydration takes place largely by diffusion of water
reduction in strength, but strength must derive from molecules into the unhydrated cement; the resulting
bonds, chemical or physical, in the mass of concrete. hydrates are sometimes referred to as internal
How do we reconcile the “water-cement ratio rule” with hydration products.
the role of the bonds? We should note in passing that the transition zone
A second question concerns the validity of the does not exist in hydrated neat cement paste and is
water-cement ratio rule for values of w/c between 0.42 present to a much smaller extent in mortar. The
and 0.22, given that for these values of w/c all the differences between the strengths of mortar and of
originally water-filled space will have been filled by the concrete will be discussed in a later section.
products of hydration of cement when maximum The extent of the transition zone has been found to
hydration has occurred. depend on the w/c of the mixture; at very low values of
A third question concerns any possible difference w/c, the transition zone is absent because there is little
between the strength of hydrated neat cement paste water-filled space to permit solution and precipitation. In
and the strength of mortar and concrete containing the consequence, hydration proceeds by diffusion only. An
same paste. interpretation of this situation is that, at very low values
To try to answer the first question, we should of w/c, the influence of the w/c on strength is not due to
return to the concept of workability water. The need the presence of capillary pores created by hydration but
for this water in portland cement mixtures without through the quality of the hydrated cement paste. The
any admixtures arises from the presence of electrical two influences on the w/c are, however, quite closely
charges upon the surface of anhydrous cement particles. connected, as will be shown in the next section.
These charges cause flocculation of cement particles,
which has a negative effect on workability and INFLUENCE OF BONDS
impedes early hydration. The preceding discussion permits us to address the
Unlike the situation half a century ago, it is now issue of bonds within the hydrated cement paste in
possible to deflocculate cement particles by means relation to compressive strength. We have just shown
of inclusion of high-range water-reducing admixtures that bonds, as well as porosity, influence strength. That
in the mixture. These specific organic molecules are the development of bonds is more difficult in mixtures
very effective in neutralizing the electrical charges with a high w/c can be seen from Fig. 1. This figure
on the surface of cement particles, either by an shows that, at a w/c of 0.65, the products of hydration
electrostatic process (as in the case of polynaphthalene, have to extend a considerable distance to create inter-particle
polymelamine, and lignosulfonates) or by steric bonds that give the hydrated cement (and concrete) its
hindrance (as in the case of polycarboxylates and strength. Thus, high w/c influences directly the development
polyacrylates). The effect of high-range water-reducing of bonds, both in slowing down the increase in strength
admixtures is to liberate water that would otherwise be and in its ultimate value.
trapped in the flocs of cement particles. In consequence, Although we have mentioned the influence of porosity
a smaller amount of mixing water will provide the on strength separately from the influence of bonds,
required workability. they are not distinct: a higher porosity means weaker
It is thus possible to make workable concrete with a bonds because of the distances over which they need
w/c down to a value as low as 0.22, that is, without any to develop. Thus, bonds are the fundamental factor
workability water. Hence, Eq. (4) would not be expected affecting strength.
to be valid—and yet it is valid! We believe that the concept of bonds as a fundamental
factor affecting strength, with the w/c influencing the
INFLUENCE OF TRANSITION ZONE strength of bonds, is an important contribution to the
A study of concretes made with high values of w/c, understanding of the strength of concrete at a practical
such as those used by Féret, Abrams, and Powers, level. This concept puts the w/c rule in its proper place.
reveals that the porosity of the hydrated cement paste Nevertheless, we have to admit that we are avoiding a
in the vicinity of aggregate, mainly the coarse aggre- closer definition of the term “bonds.” They could be
gate, is higher than the porosity of the paste further adhesion and cohesion forces. Or the quality of the

54 AUGUST 2003 / Concrete international


bonds could depend on the
absence of microcracking developing
at the time of early hardening,
following setting. Or their quality
could be the absence of differential
deformation due to shrinkage.
Alternatively, the quality of bonds
could be adversely affected by
differences in the modulus of
elasticity, Poisson’s ratio, and the
coefficient of thermal expansion
between the hydrated cement paste
and the aggregate. These questions
remain to be answered, but they
are more in the domain of science
than engineering.

RHEOLOGICAL ASPECTS
OF M /?
We have seen how the value of
w/c influences the development of
bonds. Their development in the
period immediately following
mixing has a direct effect on the
workability of the mixture. The
traditional approach to ensuring an
adequate workability is to provide
some workability water, that is, to
have large spaces between the
particles of unhydrated cement.
At the same time, to ensure reasonably
rapid construction requires the
development of some early
strength. This can be satisfied by
the use of cement with a chemical Fig. 3: Schematic representation of the hydration of a paste with high w/c made with
portland cement with a high content of C3A
composition such that some
crystals grow fast; these are the products of hydration as of C3A, and also a high fineness. Such cements have
of C3A, namely ettringite. They do not reduce workability serious disadvantages, in addition to too rapid a loss of
because the cement particles are far apart. The workability. Briefly, these disadvantages are: development
crystal growth in cements having a high C3A content of high early heat of hydration, increased shrinkage,
in mixtures with a high w/c is shown diagrammatically increased creep (which may or may not be harmful), a
in Fig. 3. higher risk of sulfate attack, risk of delayed ettringite
Now, the use of cements with a high C3A content in formation—if concrete is subjected to steam curing, and
mixtures with a low w/c is unsatisfactory: it can be possibly higher carbonation.
imagined that a rapid growth of hydrates between At low values of w/c, a high content of C3A is
closely spaced particles of cement leads to a rapid loss unnecessary because early development of strength
of workability. Using scanning electron microscopy, is ensured by products of hydration of C3S and
however, we have not observed needles of ettringite. C2S, namely C-S-H, overlapping between adjacent
Also, crystals of C-S-H are sparse, the appearance of cement particles. Achieving a satisfactory workability
C-S-H being rather that of an amorphous mass. We are at low values of w/c, however, necessitates the use of
aware, however, that other investigators did see high-range water-reducers in the mixture. The use of
ettringite in a similar situation. cement with a low content of C3A results in
In the latter part of the 20th century, and in response concrete having a low porosity and a lower risk of
to the demand for early development of strength, the sulfate attack. It should be emphasized that cements
cement manufactured had a high content of C3S, as well with a low content of C3A are unsatisfactory at high

Concrete international / AUGUST 2003 55


strength and w/c considered so far
for hydrated cement paste apply
equally in the presence of aggregate?
Concretes are made with a wide
variety of aggregates, and generally
the strength of the aggregate is not
considered. The assumption is that
the compressive strength of aggregate
per se does not affect the strength of
concrete, provided that the strength
of aggregate is higher than the
strength of hydrated cement paste,
and is also higher than the bond
between the hydrated paste and the
aggregate particles. Admittedly, the
latter is not measured directly, but
it is evidenced by the mode of
failure of concrete specimens in a
compression test: if the failure takes
place largely at the aggregate-paste
interface, the bond is taken to be
weaker than the strength of the
hydrated cement paste, and also
weaker than the strength of the
aggregate. Thus, looking at a specimen
after it has been tested in compression
is instructive. It is only fair to add
that this is a qualitative assessment
because the actual stresses involved
are not properly considered.
The preceding discussion might
be thought to lead to the conclusion
that the strength of concrete is
Fig. 4: Disadvantages of portland cement having a low C3A content in mixtures with a
governed solely by the strength
high w/c of the hydrated cement paste.
A corollary of such a situation
values of w/c if high early-strength development is would be that the strength of the hydrated cement
required (Fig. 4). paste with a given w/c is the same as the strength of
In other words, cements with high contents of C3A and concrete containing that hydrated cement paste.
C3S are desirable for mixtures with a high w/c, but the Whether or not this is so has not been reliably
use of such cements may entail disadvantages with established. One reason is that it is very difficult to make
respect to durability. On the other hand, for mixtures test specimens of neat cement paste, except very small
with a low w/c, it is preferable to use cements having ones, because of the rise in temperature upon hydration
low contents of C 3A and C3S, but as already mentioned, of cement. On the other hand, concrete specimens
a high-range water-reducer must be incorporated in require the least dimension that is a multiple of the
the mixture. maximum aggregate size; for example, ASTM C 31
prescribes a ratio of 3.
STRENGTH OF MORTAR AND OF CONCRETE More generally, it has been accepted for quite some
This article so far has dealt principally with the time that, in order to characterize the strength of
strength of hydrated cement paste, but we mentioned cement, tests are performed on specimens of mortar or
the influence of the transition zone on the properties of of concrete containing that cement and not a neat
hydrated cement in concretes with a w/c higher than cement paste. The interaction between cement and
about 0.40. This brings us to the question posed earlier concrete in practice has been studied by Neville.8
in this article: Is there any effect of aggregate on Let us now look at the strength of mortar as compared
strength? In other words, does the relation between with the strength of concrete, both materials having the

56 AUGUST 2003 / Concrete international


same w/c. It is interesting to note the comment by Carino and Tank tested seven mortar and concrete
Struble9 to the effect that evidence for relying on the mixtures, with values of w/c of 0.45 and 0.60, made
strength of cement paste at the same w/c and degree of with portland cement Types I, II, and III alone,
hydration to predict the strength of concrete is “generally and with Type I cement together with one of the
lacking.” Also, as reported by Gaynor,10 ASTM Committee following: fly ash, ground granulated blast-furnace slag,
C 01 expressed the view: “Caution must be exercised in an accelerator, and a retarder. What is relevant to the
using the results of this method (ASTM C 109 to measure present study is that, considering all these tests at
the strength of mortar) to predict the strength of concretes.” both values of w/c, they found a good linear relation
Gaynor says further: “...cement manufacturers are between the values of the rate constant for strength
reluctant to assume that these strengths (of mortar) development, kr, for concrete and for mortar, but the
bear any formal relationship to strength performance in values of kr for concrete are about 18% greater than
concrete.” Nevertheless, Gaynor concluded his paper by those for mortar. This means that, for equal long-term
saying that there is a correlation between tests on strength, the initial rate of strength development in
mortar and the performance of cement in concrete. The concrete is higher than in mortar.
term “performance” is not quite the same as strength. The objective of the work by Carino and Tank 12
On the other hand, Weaver, Isabelle, and Williamson,11 was to make it possible to estimate the relative
who are cement manufacturers, say about their study: “No strength development of concrete cured at different
correlations of strength from any of the mortar tests with temperatures from tests on mortar with the same w/c.
the 28-day strength of concrete were found in the study, The conclusion that we can draw from their work is
even when the concrete was made to the standard mix that the relative strength development is independent
proportions.” An explanation of this statement was offered of the w/c (0.45 or 0.60). This finding suggests that the
by Neville.8 With admixtures and different cementitious presence of coarse aggregate does not affect the rate
materials, the relation is likely to be more problematic. of strength development. However, there may be an
There is also a difference between mortar and concrete influence of the coarse aggregate on the value of
in that, in the latter, the relative volume of hydrated cement strength, but this cannot be established from the tests
paste is lower than in the former. This means that the by Carino and Tank.
relative volume of voids in concrete, that is, its porosity, is In passing, we can mention that very limited tests by
lower than in the mortar. Conceptually, we could expect, Kolias13 have shown correlations between the porosity
therefore, the strength of concrete to be higher. Thus, the of the cement paste and the strength of mortar, and
aggregate content in the mixture should affect it strength. between the porosity of the cement paste and the
But is this so? No conclusive evidence is available, and strength of concrete; but the two correlations are not
what there is, is unclear—not to say confusing. the same.
We are not looking for equality of strength of mortar and
concrete, if only because the test specimens used for the two CONCLUSIONS
materials are not of the same shape and size, and it is known We have reviewed the well-known relationship
that shape and size affect the strength determined by test. between compressive strength of concrete and the
The characteristics of test specimens do not affect the w/c, which is based on porosity, and we have
inherent strength, but inherent strength is an elusive concept. also recognized that porosity is not a factor in this
It is useful to add that the characteristics of the test relationship at very low values of w/c. It follows that
specimens influence the temperature rise of mortar or bonds within the hydrated cement paste must be the
concrete caused by the exothermic reactions of hydration governing influence on strength. The considerations
of cement. To remove the temperature effect, tests can be of porosity and of bonds can be combined by appreciating
conducted under isothermal conditions. Such tests were that porosity affects the strength of bonds through
performed by Carino and Tank.12 In their experiments, the influence of the distance between hydrating
they determined the rate constant for strength develop- surfaces. Thus, a single relation between strength
ment at the reference temperature of 23 °C, with kr and w/c is based on the concepts of bonds as a
expressed in (day)–1. This parameter is used in their fundamental factor.
equation for relative strength, that is, the ratio of strength Our study of the relation between the strength of
S at the equivalent age at reference temperature (te ) to the mortar and the strength of concrete, both materials
compressive strength at infinite age, Su. Using the symbol containing a cement paste with the same w/c, has
tor for the age at the start of strength development at the failed to establish a physical explanation of the
reference temperature, they express relative strength as available test results.
The w/c influences the rheological behavior of
(9) concrete. At high values of w/c, that is, when no high-
range water reducers are included in the mixture, a

Concrete international / AUGUST 2003 57


higher workability and a reasonably rapid development 3. Neville, A. M., Properties of Concrete, 4th Edition, Longman &
of strength are obtained using cements with high John Wiley, 1995, 844 pp.
contents of C 3A and C3S; however, such cements may 4. Mather, B., and Hime, W. G., “Amount of Water Required for
lead to undesirable properties of concrete in terms Complete Hydration of Portland Cement,” Concrete International,
of durability. On the other hand, at low values of w/c, V. 24, No. 6, June 2002, pp. 56-58.
when high-range water reducers are used, cements 5. Sandstedt, C. E.; Ledbetter, W. B.; and Gallaway, B. M., “Prediction of
with low contents of C3A and C3S lead to the production Concrete Strength from the Calculated Porosity of the Hardened Cement
of concrete with a satisfactory workability, early Paste,” ACI JOURNAL, Proceedings V. 70, No. 2, Feb. 1973, pp. 115-116.
strength, and durability; we are still studying the 6. Aïtcin, P.-C., High Performance Concrete, E & FN Spon,
mechanisms involved. 1998, 591 pp.
Finally, understanding how the w/c affects the 7. Rao, G. A., “Role of Water-Binder Ratio on the Strength
strength of concrete is not just a matter of scientific Development in Mortars Incorporated with Silica Fume,” Cement and
curiosity. Such understanding should help us to choose Concrete Research, V. 31, 2001, pp. 443-447.
suitable mixture proportions and thus achieve better 8. Neville, A., Neville on Concrete, Section 4.1, American Concrete
concrete in practice. Institute, Farmington Hills, MI, 2003, 519 pp.
9. Struble, L., “The Performance of Portland Cement,” ASTM
References Standardization News, Jan. 1992, pp. 38-45.
1. Féret, R., “Sur la compacité des mortiers hydrauliques,” 10. Gaynor, R. D., “Cement Strength and Concrete Strength—An
Annales des Ponts et Chaussées, 2nd semester, 1892, pp. 5-61. Apparition or a Dichotomy?,” Cement, Concrete, and Aggregates,
2. Abrams, D. A., “Design of Concrete Mixtures (1925),” A ASTM, 1993, pp. 135-144.
Selection of Historic American Papers on Concrete 1876-1926, SP-52, 11. Weaver, W. S.; Isabelle, H. L.; and Williamson, F., “A Study of
H. Newlon, Jr., ed., American Concrete Institute, Farmington Hills, MI, Cement and Concrete Correlation,” Journal of Testing and Evaluation,
1976, pp. 309-330. V. 2, No. 4, 1974, pp. 260-303.
12. Carino, N., and Tank, R. C., “Maturity Functions of Concrete
Made with Various Cements and Admixtures,” ACI Materials Journal,
V. 89, No. 2, Mar.-Apr. 1992, pp. 188-196.
13. Kolias, S.; “Investigation of the Possibility of Estimating
Concrete Strength by Porosity Measurements,” Materials and
Structures, V. 2, 1994, pp. 265-272.

Selected for reader interest by the editors after independent expert


evaluation and recommendation.

ACI member Pierr e-C


e-Cll aude Aït
Pierre-C Aïtcc in is
Professor Emeritus of Civil Engineering at
the University of Sherbrooke. He was a
member of ACI Committees 234, Silica
Fume in Concrete, and 363, High-Strength
Concrete. He is a member of the Canadian
Academy of Engineering.

ACI Honorary Member Ad am Nev


Adam Nevii l l e is
the author of a new book, Neville on
Concrete, recently published by ACI. This
is his ninth and, he says, last book.

58 AUGUST 2003 / Concrete international

Das könnte Ihnen auch gefallen