Beruflich Dokumente
Kultur Dokumente
Rang Kap
Rang Kap
START
Penulangan torsi
Hitung:
Acp = b.h
Pcp = 2.(b+h)
Aoh = (b-s-0,5.Øsengkang).(h-s-0,5.Øsengkang)
Ph = 2.(b-s-0,5.Øsengkang)+(h-s-0,5.Øsengkang)
Tak perlu
tulangan torsi OKE
Cek penampang:
. ℎ 2
²+ ≤ Ø +
. 1,7. ℎ . NOT OKE
OKE
A B
243
A B
Hitung:
1. hitung tulangan puntur untuk geser:
. . .
Tn = cot
2. hitung tulangan puntir untuk lentur:
Al = .Ph. .cot²
3. Luas tulangan torsi perlu:
Asperlu = 2.
Penulangan lentur
Hitung:
Mn = Mu/ϕ
D, d’, d”
Xb = .
Xrencanan ≤ 0,75 Xb
, . . . .
Asc =
.
Mnc = Asc . Fy . −
OKE Mn – Mnc> 0
NOT OKE
C D E
244
C D E
Hitung:
Hitung:
- Rn =
Cs =
"
"
Fs’ = . 600 -m =
,
Jika fs’ > fy, maka tulangan tekan leleh ,
fs’ = fy - ρmin =
Jika fs’ > fy, maka tulangan tekan tidak ,
leleh, maka: - ρbalance =
Ass = t/fy - ρmax = 0,75.ρbalance
As =
,
- ρperlu = 1− 1−
Tulangan perlu:
As’ = Asc + Ass - As = ρ . b . d
As = As’
Hitung:
As aktual = n . luas D tul
As’ aktual = n . luas D tul
d aktual = h – 2.selimut – Øsengkang – ½ D lentur
a = As aktual Fy – As’ aktual Fs’
Mn aktual = o,85.fc.β.d.(d’ – a/2) + As’ aktual.fs’.(d’-
d”)
Mn aktual > Mn
NOT OKE
OKE
Penulangan geser
E F
245
E
F
Cek kondisi:
-kondisi 1
- kondisi 2
- kondisi 3
- kondisi 4
- kondisi 5
- kondisi 6
Hitung:
.
Av =
.
Smax = d/2
Gambar rencana
FINISH
(1,2D+1L-1Ex)
Tn = 30689300 Nmm/0,75
= 40919066,67 Nmm
+ ≤ +
, ²
(SNI 03-2847-2002 psl. 13.6.3.1(a))
,
+ ≤
, , ²
, √
+
,
1,884 ≤ 3,125 (OKE)
* Maka penampang balok mencukupi untuk
menahan momen puntir yang terjadi
=
,
=
= 0,634 mm²
* Kontrol:
Alperlu ≥ Almin
624,207 mm² ≥ 625,792 mm² (NOT OKE)
Maka gunakan Almin.
Asperlu = 2 x Al/4
= 2 x 156,448
= 312,896 mm²
= 332694625 Nmm
Xb = ( )
=( )
540,5
= 324,3 mm
Xmin = 59,5 mm
Xrencana = 90 mm
Asc =
=
= 1625,625 mm²
Mnc = Asc x fy x −
,
= 1625,625 x 400 x 540,5 −
= 326588062,5 Nmm
Mns = Mn – Mnc
= 332694625 Nmm – 326588063 Nmm
= 6106562,5 Nmm > 0
(PERLU TUL. TEKAN)
* Maka untuk analisis selanjutnya digunakan
perhitungan penulangan tulangan rangkap.
Cs’ = Ts =
,
=
, ,
= 12695,556 N
Syarat:
Mnpasang ≥ Mnperlu
387243242,9 Nmm ≥ 332694625 Nmm (OKE)
Xb = ( )
=( )
540,5
= 324,3 mm
Xmin = 59,5 mm
Xrencana = 90 mm
Asc =
=
= 1625,625 mm²
Mnc = Asc x Fy x −
,
= 1625,625 x 400 x 540,5 −
= 326588062,5 Nmm
Mns = Mn – Mnc
= 360434500 Nmm – 326588063 Nmm
= 33846437,5 Nmm > 0
(PERLU TUL. TEKAN)
* Maka untuk analisis selanjutnya digunakan
perhitungan penulangan tulangan rangkap.
=
, ,
= 70366,814 N
= 1983,695 mm²
Syarat:
Mnpasang ≥ Mnperlu
387243242,9 Nmm ≥ 360434500 Nmm
(OKE)
Daerah lapangan
Mu = 145189700 Nmm
Mn =
=
,
= 181487125 Nmm
264
Xb = ( )
=( )
540,5
= 324,3 mm
Xmin = 59,5 mm
Xrencana = 90 mm
Asc =
=
= 1625,625 mm²
Mnc = Asc x fy x −
,
= 1625,625 x 400 x 540,5 −
= 326588062,5 Nmm
Mns = Mn – Mnc
= 181487125 Nmm – 326588063 Nmm
= -145100938 Nmm > 0
(TAK PERLU TUL. TEKAN)
* Maka untuk analisis selanjutnya digunakan
perhitungan penulangan tulangan tunggal
,
ρbal =
265
Rn =
²
=
, ²
= 1,55
m =
,
=
,
= 18,82
ρperlu = 1− 1−
, ,
= 1− 1−
,
= 0,004
≈ 2 D19
Syarat:
Mnpasang ≥ Mnperlu
232978049,8 Nmm ≥ 181487125 Nmm
(OKE)
269
Syarat:
Mnpasang ≥ Mnperlu
177001030,8 Nmm ≥ 96981200 Nmm
(OKE)
Mn-kiri (Mnl)
= 391839133,3 Nmm(momen pasang)
Mn-kanan (Mnr)
= 177001030,8 Nmm (momen pasang)
Cek kondisi:
- Kondisi 1 : Vu ≤ 0,5 x ϕ x Vc
- Kondisi 2 : 0,5 x ϕ x Vc ≤ Vu ≤ ϕ x Vc
- Kondisi 3 : ϕ x Vc ≤ Vu ≤ ϕ x (Vc + Vsmin)
- Kondisi 4 : ϕ x (Vc + Vsmin) ≤ Vu ≤ ϕ x (Vc +
Vsmax)
274
Kontrol:
Kondisi 4
ϕ x (Vc + Vsmin) ≤ Vu ≤ ϕ x (Vc + Vsmax)
0,75 x (180166,667 + 72066,667) ≤ 222433,47 ≤
0,75 x (180166,667 + 360333,333)
189175 ≤ 222433,47 ≤ 405375
Tulangan geser:
Vu = ϕ Vn
(SNI 03-2847-2002 psl 13.1.1)
Vu = ϕ Vu – ϕ Vc
ϕ Vs = Vu – ϕ V c
( )
Vs =
, ( , , )
=
,
= 116411,294 N
, ,
=
,
= 176,362 mm
- Spakai ≤ Sperlu
- Spakai ≤ d/4 pada daerah tumpuan
- Spakai ≤ 8 D lentur
- Spakai ≤ 24 Ø geser
- Spakai ≤ 300 mm
Kontrol:
- 150 mm ≤ 176,362 mm
- 150 mm ≤ 135,125 mm
- 150 mm ≤ 152 mm
- 150 mm ≤ 240 mm
- 150 mm ≤ 300 mm
Maka, dipasang Ø10-130 (dengan sengkang
2 kaki)
Sengkang pertama dipasang < 50 mm dari
muka kolom (SRPMM)
Wilayah lapangan:
Vu = +
,
= + 112683,84
= 193946,720 N
Cek kondisi:
276
- Kondisi 1 : Vu ≤ 0,5 x ϕ x Vc
- Kondisi 2 : 0,5 x ϕ x Vc ≤ Vu ≤ ϕ x Vc
- Kondisi 3 : ϕ x Vc ≤ Vu ≤ ϕ x (Vc + Vsmin)
- Kondisi 4 : ϕ x (Vc + Vsmin) ≤ Vu ≤ ϕ x (Vc +
Vsmax)
- Kondisi 5 : ϕ x (Vc + Vsmin) ≤ Vu ≤ ϕ x (Vc +
2Vsmax)
Kontrol:
Kondisi 4
ϕ x (Vc + Vsmin) ≤ Vu ≤ ϕ x (Vc + Vsmax)
0,75 x (180166,667 + 72066,667) ≤ 193946,72 ≤
0,75 x (180166,667 + 360333,333)
189175 ≤ 193946,72≤ 405375
Tulangan geser:
Vu = ϕ Vn
(SNI 03-2847-2002 psl 13.1.1)
Vu = ϕ Vu – ϕ Vc
ϕ Vs = Vu – ϕ Vc
( )
Vs =
, ( , , )
=
,
= 78428,96 N
= 158,268 mm²
- Spakai ≤ Sperlu
- Spakai ≤ d/2 pada daerah lapangan
- Spakai ≤ 8 D lentur
- Spakai ≤ 24 Ø geser
- Spakai ≤ 300 mm
Kontrol:
- 150 mm ≤ 261,773 mm
- 150 mm ≤ 270,25 mm
- 150 mm ≤ 152 mm
- 150 mm ≤ 240 mm
- 150 mm ≤ 300 mm
Maka, dipasang Ø10-150 (dengan sengkang
2 kaki)
=
(SNI 03-2847-2002 psl. 14.2.2)
λd = ≥ 300
√
Dimana:
λd = Panjang penyaluran tulangan kondisi
tarik,
db = Diameter tulangan
α = Faktor lokasi penulangan (1)
(SNI 03-2847-2002 psl. 14.2.4)
β = Faktor pelapis (1,5)
(SNI 03-2847-2002 psl. 14.2.4)
Maka:
λd = ≥ 300
√
,
= ≥ 300
√
= 1368 mm
λreduksi = x λd
,
= x 1368
,
= 1350,27 mm
Jadi panjang penyaluran dipakai 1400 mm
λdb = ≥ 0,04 x db x fy
(SNI 03-2847-2002 psl. 14.3.2)
= ≥ 0,04 x 19 x 400
√
280
= 380 mm ≥ 304 mm
λdb modif = F modif x λdb ≥ 200 mm
= x λdb ≥ 200 mm
(SNI 03-2847-2002 psl. 14.3.3.2)
,
= x 380 ≥ 200 mm
,
= 172,736 mm ≥ 200 mm
Jadi panjang penyaluran dipakai 200 mm
Kontrol retak
(SNI 03-2847-2002 psl. 12.6)
Z = fs √
≤ 30 Mn/m untuk struktur dalam ruangan
≤ 25 Mn/m untuk penampang yang
dipengaruhi cuaca luar
fs = 0,6 x fy
(SNI 03-2847-2002 psl. 12.6.4)
= 0,6 x 400
= 240
dc = selimut + ½ D tulangan
= 40 + 19/2
= 49,5 mm
Z = fs √
= 240 x 49,5 5657,142
281
= 15701,652 N/mm
= 15,7 MN/m ≤ 30 MN/m (OKE)
Panjang kait
6 D = 6 x 10
= 60 mm
(PBBI 1971, Bab 8.2)
282
Tumpuan:
Lapangan:
Panjang kait: