Sie sind auf Seite 1von 1

According to PST-RO17-SA-CTU-EDDT-18400-Ref [06E]

Minimum R.F.T required for road deck side elements 2&3 = 9.63cm2/m

As.Prov in design drawings= 10.4cm2/m with grade B500

As.Prov/ As.requ = 1.08

A large amount of Al-Ashrey reinforcement with grade B460 and Diameter 12 mm


supplied to JV by the client

The difference between supplied and design grades = 500/460=1.087

`This difference will be covered by the difference between As.Prov and As.requ

Accurate calculation for As.min

Reference to En 1992-1-1:2004/7.3.2 Minimum reinforcement areas

As.min=Kc K fct,eff Act / δs

δs = 460 [N/mm2]

K= 1 h<300 mm

H=300 [mm]

H*=300 [mm] h<1m

K1=.67 k1=2h*/3h

fctm = 3.21 [N/mm2]

fct,eff= 3.21 [N/mm2]

δc=0 [N/mm2]

Kc=0.4 conservatively will be considered 0.7 kc 0.4 ∗ 1 h ]


,
h*

Act=150000 [mm2]

As.min=7.33 cm2/m < 10.4 cm2

Conclusion:

For road deck side elements 2 and 3 reinforcement with grade B460 can be used
with no change in As.Prov in design drawings T12@109mm.