Indoor units
WATER SYSTEMS
R407C
A COMPLETE RANGE
FROM 6 kW UP TO 156 kW
YCSA 06 to 36
R407C
YCSA
6 to 36 kW
Technical features
YCSA / YCSA-H
6 M-MP 8 M-MP 8 T-TP 12 T-TP 18 T-TP 26 T-TP 36 T-TP
Performance Cooling capacity cooling only units (1) kW 6.1 - 6.1 8.3 - 8.2 8.4 - 8.3 12.2 - 12 17.2 - 16.8 25.7 - 25 35.7 - 35.1
Total Input Power (1) kW 2.4 - 2.5 3.3 - 3.3 3.2 - 3.3 4.1 - 4.4 7.8 - 8.2 9.4 - 10.1 14.1 - 14.7
Cooling capacity heat pump units (1) kW 5.9 - 5.8 8.3 - 8.2 8.4 - 8.3 12.2 - 11.9 18.2 - 17.8 25 - 24.6 36.7 - 36.1
Heating capacity heat pump units (1) kW 6- 6 8.5 - 8.5 8.8 - 8.8 12.8 - 13.1 19.6 - 19.9 25.2 - 25.6 33.5 - 34.1
Total Input Power cooling/heating mode (1) (2) kW 2.2 / 2.3 3.3 / 3.3 3.3 / 3.3 4.4 / 5 8.2 / 7.9 10.1 / 9.9 14.8 / 14.7
Total Input Power cooling/heating mode (1) (3) kW 2.1 / 2.3 3.3 / 3.2 3.3 / 3.2 4.2 / 4.8 7.8 / 7.6 9.7 / 9.5 14.2 / 14.1
Capacity steps % 0 - 100%
Sound power level dB(A) 70 71 71 73 74 78 81
Sound pressure level at 10 m dB(A) 40 41 41 43 44 48 51
Compressor Type Scroll Hermetic
Quantity 1
Air side heat exchanger Fans quantity 1 2
Working Ambient temp. cooling / heating mode (4) (-18ºC) -10ºC ~ 45ºC / -10ºC ~ 20ºC
Water side heat exchanger Type Plate Heat Exchanger
Unit water volume (2) Litres 29 30 30 69 70 118 119
Pump Type Circulators (3 speeds) Multistage horizontal pumps
Available pressure (1) (2) kPa 60 54 54 210 180 164 150
Pressure drop (1) (3) kPa 10 13 13 40 36 52 56
Working range water leaving temp. cooling/heating (5) ºC (-5ºC) 6ºC ~ 15ºC / 30ºC ~ 50ºC
Water connections inch 1" 1 1/4"
Dimensions & Weight H / W/ D mm 914 / 1 180 / 427 1 270 / 1 430 / 502 1 344 / 1 503 / 904
Weight pack / without pack cooling only kg 125 / 105 130 / 110 130 / 110 185 / 150 220 / 185 390 / 330 400 / 340
Weight pack / without pack heat pumps kg 105 / 115 140 / 120 140 / 120 200 / 165 235 / 200 430 / 370 440 / 380
Electrical features Voltage / Phases / Frequency V/ph/hz 230 / 1 / 50+E 400 / 3 / 50+N+E
Running current (max) (2) A 15.9 21.7 7 10.8 16.1 22.9 31.1
(1) at nominal conditions (2) version P with hydro kit (3) version without hydro kit M single phase T Three phases supply P Pack HHeat pump
(4) -18ºC with LAK option (5) below 6ºC with glycol
Nominal conditions: Cooling capacities in kW given for 7°C water leaving temperature ∆t 5ºC and 35°C ambient temperature
WATER SYSTEMS
Dimensions and
hydraulic connections
YCSA/ H 6 M-MP / 8 M-MP / 8 T-TP
REARVIEW SIDEVIEW
AIROUT
42
A 15
343
427
TOP VIEW AIRIN
WATERIN
914
42
405
C 18 1144 18
E 15 1180
40
WATEROUT
100
100
74
D 68 130
210 AIRIN
A- Water inlet Ø 1” Gas F. B- Water outlet Ø 1” Gas F. C- Auxiliary lines D- Electrical power supply E- Water refilling Ø 3/8” Gas F.
YCSA/ H 12 T-TP / 18 T-TP Only for size 18: Adapters Ø 1 1/4” Gas M. supplied with the unit
REARVIEW SIDEVIEW
A 15 AIROUT
43.5
WATERIN
415
70
Space requirements YCSA
6 to 36 kW
R407C
A COMPLETE RANGE
FROM 6 kW UP TO 156 kW
YCSA 50 to 100
YCSA 120 & 150
Technical features
YCSA / YCSA-H
50 T-TP 60 T-TP 80 T-TP 100 T-TP 120 T-TP 150 T-TP *
Performance Cooling capacity cooling only units (1) kW 49.2 - 47.9 61.2 - 59.3 78.6 - 76.5 96 - 93 119 - 118.4 156 - 153
Total Input Power (1) kW 17.9 - 19.3 23.8 - 25.7 27.4 - 29.7 38.4 - 41.4 43 - 43.6 50 - 53
Cooling capacity heat pump units (1) kW 45.4 - 45.2 65.3 - 63.5 74.3 - 72.2 90 - 87 114 - 110.8 145
Heating capacity heat pump units (1) kW 54.4 - 54.7 62.5 - 64.3 81.2 - 83.4 101 - 104.1 119.6 - 122.7 150
Total Input Power cooling/heating mode (1) (2) kW 18.7 / 19.7 22.2 / 23 28 / 29.6 38.3 / 36.5 43.3 / 39.6 50
Total Input Power cooling/heating mode (1) (3) kW 18.9 / 20 23 / 24.8 30.1 / 31.8 41.3 / 39.6 46.5 / 42.7 53.5
Capacity steps % 0-50-100% 0-25-50-75-100%
Sound power level dB(A) 84 85 88 89 86 88
Sound pressure level at 10 m dB(A) 56 57 60 61 58 60
Sound power level Low Noise version dB(A) 78 79 80 83 82 84
Sound pressure level Low Noise version at 10 m dB(A) 50 51 52 55 54 56
Compressor Type Hermetic Scroll (R407C) Hermetic Scroll (R410A)
Quantity 2 4
Air side heat exchanger Fans quantity 2 3 4
Working Ambient temp. cooling / heating mode (4) (-18ºC) -10ºC ~ 46ºC / -10ºC ~ 20ºC -18ºC ~ 46ºC / -10ºC ~ 20ºC
Water side heat exchanger Type Single Plate Heat Exchanger Dual Plate Heat Exchanger
Unit water volume (2) Litres 179 181 274 278 170 179
Pump Type Multistage horizontal pumps
Available pressure (1) (2) kPa 225 263 223 265 200 180
Pressure drop nominal (1) (3) kPa 39 42 59 60 32 30
Working range water leaving temp. cooling/heating (5) ºC (-5ºC) 6ºC ~ 15ºC / 30ºC ~ 50ºC
Water connections inch 2" 2 1/2"
Dimensions & Weight H / W/ L mm 1398 / 1004 / 2103 1400 / 1108 / 2943 1582 / 1140 / 3336 2190 / 1101 / 3416 2263 / 1101 / 3770
Weight pack/without pack cooling only kg 624 / 568 706 / 650 870 / 798 1 030 / 964 1 250 / 1 180 1 645 / 1 585
Weight pack/without pack heat pumps kg 636 / 580 720 / 604 890 / 824 1 065 / 1 000 1 280 / 1 220 1 675 / 1 615
Electrical supply Voltage/Phases/Frequency V/ph/hz 400 / 3 / 50+N+E
Running current (max) (2) A 46.4 57.7 71 91.3 100 109
(1) at nominal conditions (2) version P with hydro kit (3) version without hydro kit T Three phases supply P Pack HHeat pump
(4) -18ºC with LAK option (5) -5ºC with glycol * Provisional data
WATER SYSTEMS
Dimensions and
hydraulic connections
YCSA/ YCSA-H 50 and 60 T TP Drawings not a scale
A (2")
1410
E 50 50
248
317
C(Ø23)
D(Ø48)
145 70
347
1000
3000
INLET /
OUTLET
WATER
1000 1500
1000
R407C
A COMPLETE RANGE
FROM 15 kW UP TO 72 kW
YDC_972H
YDC_522H / YOC_762H
Technical features
Models YDCC 522H YDCC 972H YDCC1732 H YDCC 2502 H
YDCH 522H YDCH 972H YDCH 1732 H YDCH 2502 H
Performance Cooling capacity cooling only units kW 15.0 28.0 50.0 72.0
Heating capacity heat pump units (1) kW 16.5 30.5 53.5 76.5
Total Input Power kW 5 9 9.7 + 6.1 9.7 + 6.1 x 2
Capacity steps % 10 - 100 6 - 100 4 - 100 3 - 100
Sound pressure level at 1 m dB(A) 58 59 62 63
Compressor Type Digital ScrollDigital Scroll & Scroll Digital Scroll & 2 x Scroll Digital Scroll & 3 x Scroll
Quantity 1 2 3 4
Air side heat exchanger Fans quantity 1 2 2x2 3x2
Working ambient temp. cool. / heat. mode -20ºC~45ºC / -10ºC~20ºC
Refrigerant side Refrigerant connections mm 12/22 16/28 2 x 16/28 3x 16/28
Max refrigerant piping length m 20
Max height difference m 5
Water side Pump Type Circulators (3 speeds)
(Transformer Box) Water flow nominal l/h 2150 4100 7200 10350
Available pressure nominal (2) kPa 81 67 67 64
Water connections inch 1 1/2" 2" 2"+2" 2 1/2"+2x2"
Water connections type Threated male
Dimensions & Weight Height mm 1610 1650 2x1650 2x1650
(Unit) Width mm 780 780 2x780 2x780
Length mm 1330 1500 1500 + 1330 1500 + 1330 + 1330
Weight cooling only kg 250 325 325+280 325+280
Dimensions & Weight Height mm 1000 1200
(Transformer Box) Width mm 800 1000
Depth mm 300
Weight cooling only kg 80 95 150 170
Electrical supply Voltage / Phases / Frequency V/ph/hz 400 / 3 / 50+N
Combinations YDCC 522H YDCC 972H YDCC 972H + YOCC 762H YDCC 972H + 2 x YOCC 762H
YDCH 522H YDCH 972H YDCH 972H + YOCH 762H YDCH 972H + 2 x YOCH 762H
Nominal cooling capacity based on: leaving water temperature: +7ºC - Ambient air temperature: 35ºC DB (1) Only for heat pump units
Nominal heating capacity based on: leaving water temperature: +40ºC - Ambient air temperature: 7ºC DB / 6ºCWB (2) At nominal water flow
System diagram
SPLIT
DX piping (R407C), distance max. 20 m Capacity contro- Max. height difference bet-
(i.e. total piping max. 40 m) lled chiller ween condensing unit and
transformer box: 5 m
Transformer
box
HVS Digital is the latest generation of Yor k's Air - Absence of Electromagnetic Interference, compared with
Conditioners for cooling and heating. These units use the a variable speed compressor, making the system easy
Digital Scroll compressor technology that allows to ade- and less sensitve.
quate the capacity to the cooling or heating load. Thanks to - High reliability, as there is not necessary to use compli-
this innovative technology our products reach many advan- cates electronic devices to get the right capacity.
tages for our customers.
- Not necessary to use buffer tank, thanks to the modula-
- Energy saving up to 35% compared with conventional tion control
chillers.
- Not necessary to use glycol, as it is possible to use an
- High comfort because of the unit is capable to adjust the intermediate transformer box as a remote evaporator.
water outlet temperature in a ±0,5ºC, thereby it is possi-
And many other advantages that you can discover by your-
ble for the users enjoy always a comfortable ambient
self using HVS units.
temperature
System overview
HVS-System Controller
Indoor Units:
• Standard Fan Coils
• High Wall Units
• Cassettes
• Covertible consoles
• Blowers
• ...
Valve Kit
Dimensions and HVS Split
space requirements 15 to 72 kW
4 9 7 .5
1300
1610
1404
100
1484
min. 1 m
1 3 0 6 .5
min. 0 .5 m min. 0 .5 m
LW RW
92
1 7 0 -2 2 0
1330
3 5 0 -4 0 0
Anti vibr ation mountings
Condenser grill
780 (optional)
(optional)
WATER SYSTEMS
Dimensions and
refrigerant piping connections
Transfor mer box YTB_522-V
Unit Water pipe connection Refrigerant tubing Ø Weight kg
YTB_522-V 1 1/2” threaded male 12 / 22 80
Safety valve
Expansion vessel
W ater pump
1000
Air bleeding valve
Expansion valve
Liquid t ube Suction tube Suction tube Liquid t ube W ater connect ions 2 ”
Ø 1 6 mm Ø 2 8 mm Ø 2 8 mm Ø 1 6 mm threaded male connection
Pr essur e
Air bleeding gauge
valve
Safety
Plate heat valve
exchanger
Expansion
vessel
1200
Plate heat
exchanger
Expansion
valves
W ater
pump
M agnetic
valve Flow
switch
WATER SYSTEMS
R407C
A COMPLETE RANGE
FROM 15 kW UP TO 72 kW
YDC_972H- C
YDC_522H- C / YOC_762H- C
Technical features
Models YDCC 522H-C YDCC 972H-C YDCC 1732H-C YDCC 2502H-C
YDCH 522H-C YDCH 972H-C YDCH 1732H-C YDCH 2502H-C
Performance Cooling capacity cooling only units kW 15.0 28.0 50.0 72.0
Heating capacity heat pump units (1) kW 16.5 30.5 53.5 76.5
Total Input Power kW 5 9 9.7 + 6.1 9.7 + 6.1 x 2
Capacity steps % 10 - 100 6 - 100 4 - 100 3 - 100
Sound pressure level at 1 m dB(A) 58 59 62 63
Compressor Type Digital Scroll Digital Scroll & Scroll Digital Scroll & 2 x Scroll Digital Scroll & 3 x Scroll
Quantity 1 2 3 4
Air side heat exchanger Fans quantity 1 2 2x2 3x2
Working Ambient temperature cool. / heat. mode -20ºC~45ºC / -10ºC~20ºC
Water side heat exchanger Type Plate Heat Exchanger
Pump Type Circulators (3 speeds)
Water flow nominal l/h 2150 4100 7200 10350
Available pressure nominal (2) kPa 81 67 67 64
Water connections inch 1 1/2" 2" 2"+2" 2 1/2"+2x2"
Water connections type Threated male
Dimensions & Weight Height mm 1610 1650 1650 1650
Width mm 780 780 780 780
Length mm 1330 1500 1500 + 1330 1500 + 1330 + 1330
Weight cooling only kg 310 400 435 + 285 445 + 285 + 285
Electrical supply Voltage / Phases / Frequency V/ph/hz 400 / 3 / 50+N
Combinations YDCC 522H-C YDCC 972H-C 1xYDCC972H-C+1xYOCC762H 1xYDCC972H-C+2xYOCC762H
YDCH 522H-C YDCH 972H-C 1xYDCH972H-C+1xYOCH762H 1xYDCH972H-C+2xYOCH762H
Nominal cooling capacity based on: leaving water temperature: +7ºC - Ambient air temperature: 35ºC DB (1) Only for heat pump units
Nominal heating capacity based on: leaving water temperature: +40ºC - Ambient air temperature: 7ºC DB / 6ºCWB (2) At nominal water flow
System diagram
COMPACT
Capacity contro-
lled chiller
(r emovable) YOC_762 2”
1404
1300
1610
min. 1 m
92
1330
HVS Compact
15 to 72 kW
(r emovable)
1685
1300
1404
min. 1 m
92
1500
WATER SYSTEMS
R407C
A COMPLETE RANGE
FROM 40 kW UP TO 140 kW
W
YLCC 42- 152
Technical features
YLCC / YLCC-H
Models 42 62 82 102 122 152
Performance Cooling capacity cooling only units kW 40.2 64 71 96.1 116 141
Cooling capacity heat pump units kW 42.2 59.5 71 96 111 140
Heating capacity heat pump units kW 45.2 64.2 81,5 87 112 132
Capacity steps % 0-50-100% 0-25-50-75-100%
Sound power level dB(A) 79 81 82 84 86 90
Sound pressure level at 10 m dB(A) 51 53 54 56 58 62
Compressor Type Hermetic Scroll
Quantity 2 4
Air side heat exchanger Fans quantity 2
Air flow (50 Pa) m3/h 13268 20122 23304 28834 33247 38312
Working Ambient temperature cooling / heating mode ºC (-18ºC) -10ºC ~ 46ºC / -10ºC ~ 20ºC
Water side heat exchanger Type Coaxial heat exchanger
Unit water volume (2) Litres 25 28 38.2 38.2 78.5 73.5
Pressure drop cooling only (1) (3) kPa 16 43 57 94 20 46
Working range water leaving temperature cooling/heating ºC -5ºC ~ 15ºC / 30ºC ~ 50ºC
Water connections inch 2" 2 1/2" 3”
Dimensions & Weight Height mm 1 640 1 640 1 864 1 864 1 864 1 864
Width mm 2 240 2 240 2 891 2 891 3 200 3 200
Depth mm 774 929 1 000 1 000 1 300 1 300
Weight for cooling only kg 695 816 962 1 133 1 389 1 522
Weight for heat pumps kg 715 857 987 1 146 1 514 1 568
Electrical supply Voltage/Phases/Frequency V/ph/hz 400 / 3 / 50+N+E
Nominal cooling capacity based on: leaving water temperature: +7ºC - Ambient air temperature: 35ºC DB H = Heat pump
Nominal heating capacity based on: leaving water temperature: +45ºC - Ambient air temperature: 7ºC DB / 6ºCWB
1 1
2
148 1986 106
669
50(x3)
100
1640
1045
65
483
141
23
116 2018 106 451 323
3
1
Q Minimum free space (1000 mm)
W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
R Water connection F 2” Gas
774
1 1 1
2
146 2637 108
474
50(x3)
255
1864
1199
65
483
140
23
115 2670 106 675 325
3
1
Q Minimum free space (1000 mm)
W Minimum free space (500 mm)
E Draining 28 external, length 30 mm (on both side)
T Electrical connection 22 (3) 28,6 (1) 38 (1)
1000
• Pump
• Expansion tank
• Buffer tank
• Differential flow switch
• Air bleeding valve
• Service valve
• Automatic filling valve
• Draining valve
• Direct connection to the chiller
GH 200 to 600
Technical features
Codes
• HYDRO KIT GH 200 • HYDRO KIT GH 260 • HYDRO KIT GH 600 S/ 600 P
WATER SYSTEMS
CSL00 (Built in) CML00 (Built in) CEL00 (Built in) CEL20 (Built in) CEL30 (Built in)
CSR00 (Wall mounted) CMR00 (Wall mounted) CER00 (Wall mounted) CER20 (Wall mounted) CER30 (Wall mounted)
Fan speed selector Thermostat with manual fan Thermostat with manual Thermostat with auto. Thermostat with auto. fan
speed and S/W change over fan speed and automatic fan speed and automatic speed and automatic change
change over change over over for modulating valve
Fan Coil Unit LASER
1 to 9.5 kW
Model 110 112 114 216 218 220 222 224 226 228
With Cabinet
YLV-YLH 2 rows
3 rows
4 rows
YLV-YLH/AF 2 rows
Front air intake 3 rows
4 rows
Without Cabinet
YLIV-YLIH 2 rows
3 rows
4 rows
YLIV-YLIH/AF 2 rows
Front air intake 3 rows
4 rows
Options (factory fitted)
Model 110 112 114 216 218 220 222 224 226 228
Coil and heaters
1 row heating BA1
Kit electrical heater (with relay and safety switch) KREL
Built in thermostat
Fan speed selector CSL00
Thermostat with manual fan speed
CML00
and S/W change over
Thermostat with manual fan speed, dead band,
CEL00
automatic change over
Thermostat with automatic fan speed, dead band,
CEL20
automatic change over
Thermostat with automatic fan speed, dead band,
CEL30
automatic change over for modulating valve
Parallel connection
For ON/OFF valve one/FCU CBL20
WATER SYSTEMS
NOMENCLATURE
VERTICAL
VERTICAL
• 6 speed fan
• Cabinet factory fitted
• Valve factory fitted
• Electrical heater factory fitted
• Thermal or modulating valve
• Service valve
WITH CABINET WITHOUT CABINET
CSL00 (Built in) CML00 (Built in) CEL00 (Built in) CEL20 (Built in) CEL30 (Built in)
CSR00 (Wall mounted) CMR00 (Wall mounted) CER00 (Wall mounted) CER20 (Wall mounted) CER30 (Wall mounted)
Fan speed selector Thermostat with manual fan Thermostat with manual Thermostat with auto. Thermostat with auto. fan
speed and S/W change over fan speed and automatic fan speed and automatic speed and automatic change
change over change over over for modulating valve
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
Dimensions YLVR
◗
◗
R= low body
YLIVR
◗
◗
R= low body
V= vertical V= vertical
◗ I= without cabinet
UNIT SIZE
Dim 110 112 114 216 218
A 648 773 898 1023 1148
B 374 499 624 749 874
C 254 254 254 254 254
D 174 174 174 174 174
E 100 100 100 100 100
G 170 170 170 170 170
H 101 101 101 101 101
J 430 430 430 430 430
N 245 245 245 245 245
O 154 154 154 154 154
P 31 31 31 31 31
Q 47 47 47 47 47
R 304 304 304 304 304
S 88 88 88 88 88
T 87 87 87 87 87
U 65 65 65 65 65
V 47 47 47 47 47
W 84 84 84 84 84
X 214 214 214 214 214
Z 109 109 109 109 109
ø 20 20 20 20 20
kg 15 17 22 23 26
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
FEATURES CEL/CER
• Dead band for change over 5°C or 2°C (factory set • Input for window contact
2°C for 4 pipes and 5ºC for 2 pipes) • Input for Economy/ occupancy mode
• Manual fan speeds or automatic (models 20 and 30) • Output for remote alarm
• Thermostated fan control or continuous fan running • Filter alarm 600 or 1200 running hours (factory set
• Option water sensor WS for change over on coil (for 1200 hours)
2 pipes) • With electrical heater post ventilation
CML00 (Built in) • Led indicated status summer, winter or dead band • With Air sensor in the air intake destratification func-
CMR00 (Wall mounted) • Temperature setting for 7 to 30°C(comfort 20-25°C) tion (CEL only)
Thermostat with manual fan
• Plastic pins for limiting temperature range
speed and S/W change over
Compatibility tables
LASER and LOW BODY
COMPATIBILITY OPTIONS / ACCESSORIES / MODELS
STANDARD
LOW BODY
LASER CONCEALED
Code designation YLV YLH YLV-AF YLH-AF YLIV YLIH YLIV-AF YLIH-AF YLVR YLIVR
Technical features
Heaters capacities 2 kW 3 kW 2 kW 3 kW
Code 611760231 + 613120051 611760331 + 613120051 611760231 611760331
WATER SYSTEMS
Dimensions and
hydraulic connections
HKY-HKH 08 / 15 / 22 (2 pipes)
120
240 RENEWAL AIR DUCT
2 PREPUNCHED HOLE
215 Ø1 3
0 2
Ø2 3 Ø1 1
0
Ø2,9(8) Ø2 0 ELECTRICAL
CONNECTING
BOX
145
30
AIR OUTLET DUCT
PREPUNCHED HOLE Cold water
intake/outlet 35
VIEW
CASSETTE
CASING
Valve kit
- Diameter 1/2” for size 08 and 15
- Diameter 3/4” for size 22
- Factory fitted
- Thermal valve ON/OFF
- Insulated drain pan
- With service valve as standard
Easy to
connect
Save time !
Large Cassette
4 cm
A RANGE UP TO 11.6 kW
HKY-HKH 24 to 44
Technical features
Cooling capacities based on 7ºC EWT ∆t 5ºC Indoor temperature 27ºC DB / 19ºCWB
Heating capacities based on 50ºC EWT at nominal flow rate Indoor temperature 20ºC
Accessories
WATER SYSTEMS
High wall
Technical features
Convertible console
HCY-HCH 10 and 14
Infrared remote control (HCH)
• Wireless or wired version available
• 5 operations modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
Convertible console
4.1 to 5.5 kW
Technical features
Model 10 14
Fan speed High High
Total cooling capacitiy W 4110 5550
Sensible capacity W 3480 4658
Heating capacitiy W 5825 7770
Electrical data
Supply V/ph/Hz 230 / 1 / 50 + E
WATER SYSTEMS
Blowers
A RANGE FROM 7 TO 26 kW
Condensate pump
Options / Accessories
Paint finish
Electrical heaters
Capacity W 3750 7500 9000
Controls
2 pipe on/off *
Code 463B11001-001
Wall mounting 3 m
4 pipe on/off *
Code 463B11002-001
Wall mounting 3 m
2 pipe on/off+electrical heater *
Code 463B11002-002
Wall mounting 3 m