Beruflich Dokumente
Kultur Dokumente
Main objectives
1) Calculate Wind Pressure for Components and Cladding per NSCP 201
2) Design the Roof Truss and Purlins per NSCP 2015/AISC 360-10 by LRF
3) Derive dead load and live load values per NSCP 2015
4) Discuss NSCP 2015/UBC 97 Seismic parameters input to STAAD
5) Design the concrete elements in STAAD Advanced Concrete Designer
(beams, slabs, columns and footings)
ESIDENTIAL STRUCTURE USING
Concrete Designer RCDC
STORIES (LEVELS)
Footing to GF 1.8
GF to 2F 3
2F - Roof Beam 3
Roof Beam - Apex 2
9.8
Roof mean Height for wind load calculation
7.00 m
Roof Slope = 22.62deg
40km
STORIES (LEVELS)
Levels Storey Height (m)
Footing to GF 1.8
GF to 2F 3
2F - Roof Beam 3
Roof Beam - Apex 2
9.8
PROPERTIES
Beams Columns Slabs fc' fy
RB250x400 RC300X300 S115 20.68 Mpa 275 Mpa
(3000psi) (Gr40)
LOADS
Dead Load
1) Selfweight
Concrete unit weight = 24 kN/m3
2) Member Load
150mm CHB 3.11 kN/m per meter height
100mm CHB 2.98 kN/m per meter height
Live Load
1.9 kN/m2 0.60 kN/m2
Seismic Parameters
UBC 97 / NSCP 2015
Zone = 4
Seismic Source Type = A
Importance Factor ( I ) = 1.0 (Standard Occupancy)
R = 8.5 - Special Moment Frame
Structure is located 40km from seismic source
Ct = 0.0731
Wind Parameters
Wind (ASCE 7-10 / NSCP 2015)
Vwind = 250 kph
I = 1.0
Exposure = B (typical residential structure in urban area)
DL LL
0.71 0.6
2.5 1.775 1.5
1.25 0.8875 0.75
1.77 -1.94
2.5 4.425 -4.85
1.25 2.2125 -2.425
2.63 0.24 0.24 3.11
2.5 0.24 0.24 2.98
Low-Rise Buildings : Component and Cladding
Simplified Procedure
ASCE 7-10
Pnet = λ Kzt Pnet9
1 1
PURLINS (EFFECTIVE AREA = 2.08 m2)
250kph
Zone
1 2 3
1.09 1.09 1.09 kn/m2
-1.85 -3.04 -4.57 kn/m2
PURLIN SPACING = 0.8M
WINDWARD LEEWARD
1.77 -1.94
AREA WHOLE 9 15.93 KN
area 1/2 4.5 7.965 KN
area 1/4 2.25 3.9825 KN
0.8
2.8
0.32
0.9 governs
TRUSS 1.635 KN 2.5 9.6 24 0.068125 KN/M2
0.408625 KN/M2
UBC 1997
T = Ct (hn)
0.75
PARAMETERS sec UBC Eq. (30-8)
Z 0.4 = 0.131 sec
I 1 < 0.70 sec therefore Ft = 0;
Rwx 5.5
Rwz 5.5
Na 1
Nv 1 V= CvIW KN UBC Eq. (30-4)
S 4 RT
Ct 0.0481 = 191.99 KN
hn 3.8
W 216
Cv 0.64
Ca 0.44
If Ft≠ 0:
Ft = 0.07TV UBC Eq. (30-14)
= 1.76 KN
< 0.25V = 48.00
1.5 kn/m^2
external X Y LOAD kn
AREA/2 2.5 1.25 0.5 1.5625
AREA 2.5 2.5 0.5 3.125
INTERAL FRAME
X Y LOAD KN
AREA/2 5 1.25 0.5 3.125
AREA 5 2.5 0.5 6.25
wind 1.75
2.5 4.375
5 8.75
0.004202
1.2 DL + 1.00 E + 0.5 LL
1 1.400 D
2 1.200 D + 1.600 Lp
3 1.420 D + 0.500 Lp + 1.250 E1
4 1.420 D + 0.500 Lp + 1.250 E2
5 1.420 D + 0.500 Lp - 1.250 E1
6 1.420 D + 0.500 Lp - 1.250 E2
7 1.420 D + 1.250 E1
8 1.420 D + 1.250 E2
9 1.420 D - 1.250 E1
10 1.420 D - 1.250 E2
11 0.680 D + 1.250 E1
12 0.680 D + 1.250 E2
13 0.680 D - 1.250 E1
14 0.680 D - 1.250 E2
E = ρ Eh + Ev
1.25
= 1.25 Eh
Ev = 0.5 Ca I DL
0.5 0.44 1 DL
= DL
= 0.22 DL
Isolated Footing Design
Eccentric Isolated Footing Design
Combined Footing Design