SY3000/5000

Series
Base Mounted Monifold
Stacking Type/DIN Rail Mounted
Type 45 Individual Wiring
How to Order Manifold How to Order Valve Manifold Assembly

SS5Y 3 45 05 U C6 Ordering example

Series Valve stations Double solenoid (24 VDC)


SY3240-5G (2 sets)
3 SY3000 02 2 stations
Single solenoid (24 VDC)
...

...

5 SY5000
20 20 stations SY3140-5G (2 sets)
Blanking plate assembly
SUP/EXH block assembly SX3000-75-1A
mounting position Cylinder port size
Symbol Mounting position Applicable no. of stations C6: With One-touch fitting for ø6

U U side +

2 to 10 stations +
— Manifold base (5 stations)
D D side +

+ SS5Y3-45-05D-C6
B (Both sides) 2 to 20 stations U
M∗ Special specifications sid
e
∗ For special specifications, indicate separately Sta
tio
on the manifold specification sheet. ns

A, B port size 3
2
One-touch fitting (Metric size) One-touch fitting (Inch size) 1 D
sid
Symbol Port size Applicable series Symbol Port size Applicable series e
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
M Mixed M Mixed
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
SS5Y3-45-05D-C6 1 set (Type 45, 5 stations manifold base part no.)
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" ∗ SX3000-75-1A 1 set (Blanking plate assembly part no.)
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16" ∗ SY3140-5G 2 sets (Single solenoid part no.)
M Mixed M Mixed ∗ SY3240-5G 2 sets (Double solenoid part no.)
∗ In the case of mixed specifications (M), indicate separately on the
manifold specification sheet.
Option The asterisk denotes the symbol for assembly.
.
Prefix it to the part nos. of the solenoid valve, etc
When a longer DIN rail is desired than the
specified stations, specify the station number The valve arrangement is numbered as the 1st. station from D side regardless of
to be required. (20 stations at maximum) the mounting position of SUP/EXH block assembly. In ordering, specify the part
nos. in the order from the 1st. station on D side. Besides, when the arrangement
will be complicated, fill out the manifold specification sheet to instruct us.
For external pilot specifications and built-in silencer,
refer to catalog on page 1-4-194.

1-4-120
Base Mounted

Series SY3000/5000

How to Order Valves

SY 5 2 40 5 L

Series Manual override


3 SY3000 Nil Non-locking push type
5 SY5000 D Push-turn locking slotted type
E Push-turn locking lever type SV
Light/Surge voltage suppressor SZ
Type of actuation Electrical entry for G, H, L, M, W
1 2 position single Nil Without light/surge voltage suppressor SY
2 2 position double S With surge voltage suppressor
3 3 position closed center Z With light/surge voltage suppressor SYJ
4 3 position exhaust center R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
5 3 position pressure center SX
∗ For AC voltage valves there is no “S” option. It is
already built-in to the rectifier circuit.
Coil specifications
∗ For “R” and “U”, DC voltage is only available.
Nil Standard ∗ Power saving circuit is only available in the "Z" type.
With power saving circuit
T
(24, 12 VDC only)
∗ Power saving circuit is not available in Electrical entry for D
the case of “D”, “DO” or “W” type.
Nil Without light/surge voltage suppressor
S With surge voltage suppressor (Non-polar type)
Rated voltage Z With light/surge voltage suppressor (Non-polar type)
∗ “DOZ” is not available.
DC
∗ For AC voltage valves there is no “S” option. It is
5 24 VDC already built-in to the rectifier circuit.
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC Electrical entry
AC ( Hz) 50 60 24, 12 VDC/
1 100 VAC 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 100, 110, 200, 24, 12, 6, 5, 3 VDC
2 200 VAC 220 VAC
3 110 VAC [115 VAC] Grommet L plug connector M plug connector DIN terminal M8 connector
4 220 VAC [230 VAC] G: Lead wire L: With lead wire M: With lead wire (SY5000) WO: Without
∗ DC specifications of length 300 mm (Length 300 mm) (Length 300 mm) D: With connector connector cable
type “D” and “DO” is H: Lead wire LN: Without lead wire MN: Without lead wire DO: Without
only available with 12 length 600 mm LO: Without connector MO: Without connector connector
and 24 VDC. • “LN”, “MN” type: with 2 sockets.
∗ For type “W”, DC • D and DO only available for SY5000.
voltage is only • DIN terminal type “Y” conforming to DIN43650C standard is also available. For details, refer to page 1-4-201.
available. • For connector cable of M8 connector, refer to page 1-4-209.
∗ “D” and “DO” only
available for SY5000.

1-4-121
Base Mounted

Series SY3000/5000

Manifold Specifications

Model SS5Y3-45 SS5Y5-45


Applicable valve SY340 SY540
Manifold type Stacking type/DIN rail mounted
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 20 stations Note 1)
A, B port Location Base
Porting specifications Direction Side
P, R port C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10)
C4 (One-touch fitting for ø4)
Port size C4 (One-touch fitting for ø4)
A, B port C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6)
C8 (One-touch fitting for ø8)
Manifold base weight 2 to 10 stations: W = 22n + 118 2 to 10 stations: W = 47n + 156
W (g), n: Stations 11 to 20 stations: W = 22n + 140 11 to 20 stations: W = 47n + 190
Note 1) For more than 11 stations, supply pressure to P port on both sides and exhaust from R port
on both sides.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/ (s·bar) ) b Cv C (dm3/ (s·bar) ) b Cv
SS5Y3-45 C8 C6 0.88 0.21 0.22 0.95 0.18 0.22
SS5Y5-45 C10 C8 2.2 0.24 0.53 2.5 0.18 0.58
Note) The value is for manifold base with 5 stations and individually operated 2 position type.

1-4-122
Base Mounted

Series SY3000/5000

Manifold Option
 Individual SUP spacer assembly  Individual EXH spacer assembly  SUP block disk  SUP block disk
By installing a SUP block disk in the By installing an EXH block disk in the
pressure supply passage of a manifold exhaust passage of a manifold valve, it
valve, it is possible to supply two or is possible to divide the valve’s exhaust
more different high and low pressures so that it does not affect another valve.
to one manifold. (Two block disks are needed to divide
both exhausts.)
End plate

SV

Series Part no. Series Part no.


SZ
t t SY3000
SY3000 SX3000-77-1A SX3000-77-1A
SY5000 SX5000-77-1A SY5000 SX5000-77-1A SY
SUP port EXH port
 L Label for block disk SYJ
The labels shown below are used on manifold stations containing
SUP/EXH block disk(s) to show their location. (3 pcs. each) SX
Series Assembly part no. Port size t Series Assembly part no. Port size t
SY3000 SY3000-39-2A M5 x 0.8 11
VZ3000-123-1A
SY3000 SY3000-38-2A M5 x 0.8 11
SY5000 SY5000-39-16∗A 1 8 15 Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
SY5000 SY5000-38-16∗A 18 15
Note) The SUP port may be Note) The EXH port may be
either on the lead wire either on the lead wire
side or on the end side or on the end
plate side. plate side.

 Blanking plate assembly ∗ Thread type Note) When a block disk is concurrently ordered by specifying on
Nil Rc the manifold specification sheet, etc., a label will be stuck on
F the position where block disk is mounted.
G
N NPT  Silencer with One-touch fitting
T NPTF The silencer plugs directly into the One-touch fittings of the manifold.
C
B
Caution
Mounting screw
A

tightening torques
Series Assembly part no. M2: 0.16 N·m
SY3000 SX3000-75-1A M3: 0.8 N·m Series Model Effective area A B C
SY5000 SX5000-76-5A M4: 1.4 N·m For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
AN200-KM10 26 mm2 ø22 53.8 80.8
For SY5000 (ø10)
AN300-KM10 30 mm2 ø25 70 97
 Dimensions/DIN rail
VZ1000 11 1
Refer to L dimensions
 L Plug (white)
These are inserted in unused cylinder ports and SUP, EXH ports.
∗ Fill in  with an appropriate no. listed on the table of DIN
rail dimensions shown below. Purchasing order is available in units of 10 pieces.
ød

L
øD

A
L
Dimensions
No. 0 1 2 3 4 5 6 7 8 9 10 Applicable fittings size ød Model A L D
L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 4 KQ2P-04 16 32 6
6 KQ2P-06 18 35 8
No. 11 12 13 14 15 16 17 18 19 20 21
8 KQ2P-08 20.5 39 10
L Dimension 235.5 248 260.5 273 285.5 298 310.5 323 335.5 348 360.5
10 KQ2P-10 22 43 12
No. 22 23 24 25 26 27 28 29 30 31 32 1 8" KQ2P-01 16 31.5 5
L Dimension 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 5 32" KQ2P-03 16 32 6
1 4" KQ2P-07 18 35 8.5
No. 33 34 35 36 37 38 39 40 41 42 43
5 16" KQ2P-09 20.5 39 10
L Dimension 510.5 523 535.5 548 560.5 573 585.5 598 610.5 623 635.5
No. 44 45 46 47 48 49 50 51 52 53 54
L Dimension 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773
No. 55 56 57 58 59 60 61 62 63 64 65
L Dimension 785.5 798 810.5 823 835.5 848 860.5 873 885.5 898 910.5
No. 66 67 68 69 70 71
L Dimension 923 935.5 948 960.5 973 985.5
∗ Refer to L1 dimension on pages starting with page 1-4-126 for lengths
that correspond to the number of manifold stations.

1-4-123
Base Mounted

Series SY3000/5000

Manifold Option

 How to Order Interface Regulator (SY3000/5000 only)

Series SY3000 Series SY5000

ARBY3000 05 P 2 ARBY5000 00 P 2
Regulating port Regulating port
P P port P P port
A1 A port (P controlled type, A port regulation) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)

Pressure gauge
Pressure gauge connection port
connection port
05 Pressure gauge (G15-10-01) [for odd number station]
00 Pressure gauge (G15-10-01)
06 Pressure gauge (G15-10-01) [for even number station]
M1 Plug (M-5P)
M1 Plug (M-5P)
∗ In the case of Series ARBY3000 with
a pressure gauge when mounting on
the manifold, use caution that the part
numbers are different between the
odd no. stations and the even no.

ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2


(For mounting odd (For mounting even
number stations) number stations)

–+ –+ –+

–+ –+

Accessory Caution
Series Round head combination screw Gasket Mounting screw
SY3000-23-10 tightening torques
ARBY3000 (M2336) SX3000-57-4
M3 x 48.5,
ARBY5000 Matt nickel plated SX5000-57-6 M2: 0.17 N·m
M3: 0.8 N·m

1-4-124
Base Mounted

Series SY3000/5000

Dimensions: Series SY5000 [ ]: AC


C4, N3 C4, N3
SS5Y5-45- Stations D- C6, N7 SS5Y5-45- Stations U- C6, N7
C8, N9 C8, N9
(Pitch) (Pitch)

14.5
Button for DIN rail release P=16 17 26 Button for DIN rail release 26 17 P=16 25

14.5

15.5
31.5
31.5
15.5

32
32
A A A A A R R A A A A A

B B B B B P P B B B B B

One-touch fitting One-touch fitting


One-touch fitting One-touch fitting
P, R port
–+ –+ –+ –+
(P, R port) A, B port
(A, B port) Applicable tubing O.D.: ø10, ø3/8"
Applicable tubing O.D.: ø10, ø3/8"
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4" (Light/Surge voltage suppressor) ø6, ø1/4"
ø8, ø5/16" ø8, ø5/16"
(Lead wire length)

(Lead wire length)


Manual override DIN rail holding screw
119.8 [124.2] Approx. 300

Manual override

119.8 [124.2] Approx. 300


(4.9)

(3.5)

(4.9)
DIN rail DIN rail

(3.5)
(For DIN:

107.2 [111.6]
44.2
44.2

(For DIN

53.4 [55.6] 41.2


8 8
53.4 [55.6] 41.2
107.2 [111.6]

31.2 31.6
31.2 31.6
(For DIN: (For DIN:

: 45.5)

(For DIN (For DIN


45.5)

B B B B B B B B B B

: 32.5) : 32.9)

5.5
32.9)

35
35
5.5

48.3
A A A A A A A A A A
48.3
32.5)

L3 (L4) L3 (L4)
L2 5 DIN rail holding screw L2 5
(Rail mounting hole pitch: 12.5) (Rail mounting hole pitch: 12.5)
L1 L1

(Station n) (Station 1)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(Light/Surge voltage suppressor) L1 110.5 135.5 148 160.5 173 198 210.5 223 235.5
L2 100 125 137.5 150 162.5 187.5 200 212.5 225
71.1 [78.1]

–+ –+ –+ –+ –+
L3 84 100 116 132 148 164 180 196 212
L4 13 17.5 16 14 12.5 17 15 13.5 11.5
55.7

42.7
7.5

Block separation button


(Push type)

With interface regulator (with gauge)

(Pitch)
P=16 17 26 54.5
(87.2)
41.2

B B B
35

48.3

A A A
69.8

ø15 42.7
94.1 [101.1]

1-4-128
Base Mounted

Series SY3000/5000

DIN Rail Manifold Exploded View


Type 45
r
U side t
n
c ail tto
I N r se bu
D ea
rel
w


+ y

q

+

+

a Bolts
e
c n
ail tto
N r bu
DI ease
rel
b Block separation button
C
SM
D side

u
Replacement Parts
Part no.
No. Description Note
SY3000 SY5000
: SY3000 (Metric size) C4: With One-touch fitting for ø4 (Inch size) N3: With One-touch fitting for ø 5 32"
C6: With One-touch fitting for ø6 N7: With One-touch fitting for ø 1 4"
Manifold block SY5000 (Metric size) C4: With One-touch fitting for ø4 (Inch size) N3: With One-touch fitting for ø 5 32"
q assembly SX3000-50-1A- SX5000-50-1A-
C6: With One-touch fitting for ø6 N7: With One-touch fitting for ø 1 4"
C8: With One-touch fitting for ø8 N9: With One-touch fitting for ø 5 16"
(Gasket 6 is supplied as an accessory.)
(Metric size) (Metric size) P, R port SY3000 (Metric size) With One-touch fitting for ø8
SUP/EXH block SX3000-51-1A SX3000-51-1A (Inch size) With One-touch fitting for ø5 16"
w assembly (Inch size) (Inch size) P, R port SY5000 (Metric size) With One-touch fitting for ø10
SX3000-51-15A SX5000-51-15A (Inch size) With One-touch fitting for ø3 8"
e End block assembly R SX3000-52-1A SX5000-52-1A For D side
r End block assembly R SX3000-53-1A SX5000-53-1A For U side
Round head M3 x 26
t SY3000-23-4
combination screw (Matt nickel plated)
y Gasket SX3000-57-4 SX5000-57-6
u DIN rail VZ1000-11-1- Refer to page 1-4-123.

1-4-130
Base Mounted

Series SY3000/5000

DIN Rail Manifold Exploded View

How to Increase Manifold Base Station expansion is possible at any position. How to Change
. Fitting Assembly
1 Loosen bolt a fixing the manifold base until it begins to turn idly. Clip Type 45 manifold permits
(While pressing DIN rail releasing buttons c , at two locations, change in the A and B port
separate the manifold base from the DIN rail.) sizes by changing the
2 Press manifold block assembly dividing button b , that are at the manifold block fitting
location where manifold bases are to be added, until button b assembly.
locks, and then separate the block assemblies. After removing the valve,
remove the clip with a
SV
3 Mount additional manifold block assembly on the DIN rail as
Fitting assembly screwdriver, etc. For
shown in the Fig. (1). mounting a new fitting SZ
4 Press the block assemblies until a click sound is produced, and assembly, insert it and then
tighten the bolts a to fix them to the DIN rail. insert a clip until it will not SY
Caution (Tightening torque: 1.4 N·m) come out of the manifold
(While lightly holding the blocks after fixing an end block on one block.
side, tighten the other end block for for better sealing.) O-ring SYJ
Caution Fitting Assembly Part No. SX
Note 1) When there are 10 or fewer manifold block
Metric size
assemblies, and more are added to make a total of
11 or more, a supply/exhaust block assembly must One-touch fitting for ø4 VVQ1000-50A-C4
SY3000
also be added. One-touch fitting for ø6 VVQ1000-50A-C6
Note 2) When disassembly and assembly are performed, One-touch fitting for ø4 VVQ1000-51A-C4
air leakage may result if connections between SY5000 One-touch fitting for ø6 VVQ1000-51A-C6
blocks and tightening of the end block’s holding
One-touch fitting for ø8 VVQ1000-51A-C8
screw, is inadequate. Before supplying air, confirm
that there are no gaps, etc. between blocks, and Inch size
that manifold blocks are securely fastened to the One-touch fitting for ø 5 32" VVQ1000-50A-N3
DIN rail. Then supply air and confirm that there is SY3000
One-touch fitting for ø 1 4" VVQ1000-50A-N7
no air leakage before operating.
One-touch fitting for ø 5 32" VVQ1000-51A-N3
Fig. (1) Block mounting procedure SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø 5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust.
Otherwise, air leakage may result.

Hook the DIN rail here and press down in


the direction of the arrow until a click
sound is heard.

1-4-131
SY3000/5000
Series
Base Mounted Manifold
Stacking Type/DIN Rail Mounted
Type 45-ANA Connector Box
How to Order Manifold How to Order Valve Manifold Assembly

SS5Y 3 45 A U 05 D C6 Ordering example (SY3000, +COM, U side)


Double solenoid (24 VDC)

Series SY3240-5LOU (2 sets)


Single solenoid (24 VDC)
3 SY3000
SY3140-5LOU (2 sets)
5 SY5000 +-

CO
SM
C
Cylinder port size
BO NNEC
X TO

Specifications 24
DC V
R

+
15
14 C6: With One-touch fitting for ø6
- 6

7
Manifold base
Symbol Specifications
A With connector box (+COM spec.)
- +

- +
SS5Y3-45-AU-05D-C6
- +

NA With connector box (–COM spec.) - +

U
The style of attached lead sid
e
wire assembly is different. Sta
tion
s ....
32
Connector box Blanking plate assembly 1
mounting position SX3000-75-1A D
sDid
Symbol Mounting position e
U U side SS5Y3-45-AU-05D-C6 1 set (Type 45, 5 stations manifold base part no.)
D D side ∗ SX3000-75-1A 1 set (Blanking plate assembly part no)
∗ SY3140-5LOU 2 sets (Single solenoid part no.)
Valve stations ∗ SY3240-5LOU 2 sets (Double solenoid part no.)
Symbol Stations Note The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
02 2 stations Applicable up to
...

...

16 solenoid The valve arrangement is numbered as the 1st. station from D side
16 16 stations valves. regardless of the mounting position of connector box. In ordering, specify the
part nos. in the order from the 1st. station on D side. Besides, when the
SUP/EXH block assembly arrangement will be complicated, fill out the manifold specification sheet to
instruct us.
mounting position
SS5Y 35 -45-A UD --C is assembled with solenoid valve and lead wire
Symbol Mounting position Applicable stations assembly when shipping. When ordering manifold only (without
U U side valves/wires/options), refer to how to order on page 1-4-120 and list the
2 to 10 stations
D D side connector box (VZ3000-106-1A) and the rail stopper (TXE1-SMC) below the
B Both sides 2 to 16 stations manifold to allow for the connector box mounting at U side. (Be sure to order
DIN rail 3 station longer than number of the manifold stations.) In this case,
M∗ Special specifications
please note that dimensions, L1 and L2 on pages 1-4-136 and 1-4-137 may
∗ For special specifications, indicate separately vary slightly.) For other components, refer to page 1-4-138.
on the manifold specification sheet.

A/B port size How to Order Valves


One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Port size Applicable
. series Symbol Port size Applicable series
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6 SY3000
N3 One-touch fitting for ø5/32"
N7 One-touch fitting for ø1/4" SY3000
SY 5 2 40 5 LOU
M Mixed M Mixed
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5/32" Series
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1/4"
SY5000 SY5000 3 SY3000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5/32"
5 SY5000
M Mixed M Mixed Manual override
∗ In the case of mixed specifications, indicate separately on the Nil Non-locking push type
manifold specification sheet. Type of actuation D Push-turn locking slotted type
Option 1 2 position single E Push-turn locking lever type
When a longer DIN rail is desired than the specified stations,
2 2 position double
specify the station number to be required.
(Max. 20 stations) 3 3 position closed center
4 3 position exhaust center
For external pilot specifications and built-in silencer, 5 3 position pressure center
refer to page 1-4-194.

Rated voltage
5 24 VDC

1-4-132
Base Mounted

Series SY3000/5000

Manifold Specifications

Model SS5Y3-45-ANA SS5Y5-45-ANA


Applicable valve SY340 SY540
Manifold type Stacking type/DIN rail mounted
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations 2 to 16 stations Note 1, 2)
A, B port Location Base
Porting specifications Direction Side
P, R port C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10)
C4 (One-touch fitting for ø4) SV
Port size C4 (One-touch fitting for ø4)
A, B port C6 (One-touch fitting for ø6)
C6 (One-touch fitting for ø6)
C8 (One-touch fitting for ø8) SZ
Manifold base weight W (g) 2 to 10 stations: W = 26n + 207 2 to 10 stations: W = 52n + 245
n: Stations 11 to 20 stations: W = 26n + 229 11 to 16 stations: W = 52n + 279
Applicable flat ribbon cable Flat ribbon cable connector Socket: 20 pins MIL type
SY
connector with strain relief conforming to MIL-C-83503
Wiring specifications +COM specifications (Type 45-A), –COM specifications (Type 45-NA) SYJ
Note 1) For more than 11 stations, supply pressure to P port on both sides and exhaust from R port
on both sides. SX
Note 2) There is a limit depending on the number of solenoids. Refer to “How to Order”.

Flow Characteristics

Port size Flow characteristics


Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b Cv
SS5Y3-45- C8 C6 0.88 0.21 0.22 0.95 0.18 0.22
SS5Y5-45- C10 C8 2.2 0.24 0.53 2.5 0.18 0.58
Note) The value is for manifold base with 5 stations and individually operated 2 position type.

Manifold Wiring Diagram (Circuit diagram for the reference layout)

+COM electric circuit diagram –COM electric circuit diagram


Connector box Connector box
(Wiring example) (Wiring example)

Station 1 Station 1

Station 2 Station 2

Station 3 Station 3

Station 4 Station 4
Triangle mark Triangle mark

Station 5 Station 5

24 VDC 24 VDC
Power supply terminal Power supply terminal

SoL. B -+

Reference layout -+

• Connector box for +COM allows transmission until G71-OD16, manufactured 0

1
8

by OMRON Corp., to be connected directly for serial transmission. Additionally, 2 10 B B B B B


3 11

it can also be used for the PC wiring system. 4 12

• When an external power source must be supplied to the manifold, correct U side 5 13
A A A A A D side
CONNECTOR
6 14
BOX

polarity must be observed, otherwise damage to PLC is possible. VZ3000-106-1A


7 15

• The wiring of solenoid valves, corresponds with the labeled connector box 0 to
15 from D side. -+ -+ -+ -+ -+

• If valves other than non-polar type are used, this may cause malfunction. SoL. A SoL. A
(Station 2)
(Station n)

(Station 1)

......

1-4-133
Base Mounted

Series SY3000/5000

Manifold Option
 Individual SUP spacer assembly  Individual EXH spacer assembly  SUP block disk  EXH block disk
By installing a SUP block disk in By installing an EXH block disk in
the pressure supply passage of a the exhaust passage of a manifold
manifold valve, it is possible to valve, it is possible to divide the
supply two or more different high valve’s exhaust so that it does not
and low pressures to one manifold. affect another valve. (Two block
disks are needed to divide both
End plate End plate exhausts.)

t
t
Series Part no. Series Part no.
SUP port
SY3000 SX3000-77-1A SY3000 SX3000-77-1A
SY5000 SX5000-77-1A SY5000 SX5000-77-1A
EXH port

 Label for block disk


The labels shown below are used on manifold stations containing
SeriesAssembly part no. Port size t SeriesAssembly part no. Port size t SUP/EXH block disk(s) to show their location. (3 pcs. each)
SY3000 SY3000-38-2A M5 x 0.8 11 SY3000 SY3000-39-2A M5 x 0.8 11
SY5000 SY5000-38-16∗A 18 15 SY5000 SY5000-39-16∗A 18 15
VZ3000-123-1A
Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
Note) The SUP port may be either Note) The EXH port may be either
on the lead wire side or on the on the lead wire side or on
end plate side. (An assembly the end plate side. (An
is shipped under the condition assembly is shipped under
shown in the figure.) the condition shown in the
figure.)
 Blanking plate assembly ∗ Thread type Note) When a block disk is concurrently ordered by specifying on the
Nil Rc manifold specification sheet, etc., a label will be stuck on the
F position where block disk is mounted.
G
N NPT  Silencer with One-touch fitting
T NPTF
The silencer plugs directly into the One-touch fittings of the manifold.

Caution
Mounting screw
tightening torques
Series Assembly part no.
SY3000 SX3000-75-1A
M2: 0.16 N·m Series Model Effective area A B C
SY5000 SX5000-76-5A
M3: 0.8 N·m For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
M4: 1.4 N·m AN200-KM10 26 mm2 ø22 53.8 80.8
For SY5000 (ø10)
 Cable assembly AN300-KM10 30 mm2 ø25 70 97
1
AXT100-FC20- |
3  Plug (white)
Red
These are inserted in unused cylinder ports and SUP, EXH ports.
Purchasing order is available in units of 10 pieces.

Terminal
number
Dimensions
Applicable fittings size ød Model A L D
Connector Assembly for Flat Ribbon Cable 4 KQ2P-04 16 32 6
6 KQ2P-06 18 35 8
Cable length (L) Assembly part no. Note
8 KQ2P-08 20.5 39 10
1.5 m AXT100-FC20-1
Cable 20 core 10 KQ2P-10 22 43 12
3m AXT100-FC20-2
x 22 AWG 1 8" KQ2P-01 16 31.5 5
5m AXT100-FC20-3 5 32" KQ2P-03 16 32 6
∗ For other commercial connectors, use a 20 pins with strain relief 1 4"
conforming to MIL-C-83503.
KQ2P-07 18 35 8.5
5 16" KQ2P-09 20.5 39 10

Connector manufacturers’ example


• Sumitomo 3M Limited Warning
• Fujitsu Limited When mounting a valve or spacer on the manifold base or sub-plate, etc., those mounting
• Japan Aviation Electronics Industry, Ltd. directions are determined. If mounted in the wrong direction, the equipment to be connected may
• J.S.T. Mfg. Co., Ltd. cause malfunction. Refer to external dimensions, and then mount it.

1-4-134
Base Mounted

Series SY3000/5000

Manifold Option

 How to Order Interface regulator (SY3000, 5000 only)

Series SY3000 Series SY5000

ARBY3000 05 P 2 ARBY5000 00 P 2
Regulating port Regulating port SV
P P port P P port
A1 A port (P controlled type, A port regulation) A1 A port (P controlled type, A port regulation)
B1 B port (P controlled type, B port regulation) B1 B port (P controlled type, B port regulation)
SZ

Pressure gauge connection port Pressure gauge connection port SY


05 Pressure gauge (G15-10-01) [for odd number station] 00 Pressure gauge (G15-10-01)
06 Pressure gauge (G15-10-01) [for even number station] M1 Plug (M-5P) SYJ
M1 Plug (M-5P)
∗ In the case of Series ARBY3000 with a SX
pressure gauge when mounting on the
manifold, use caution that the part
numbers are different between the odd
no. stations and the even no. stations to
avoid gauges from interfering from each
others.

ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2


(For odd number stations) (For even number stations)

- + - + - +

- + - +

Accessory Caution
Series Round head combination screw Gasket Mounting screw tightening torques
SY3000-23-10
ARBY3000 (M2 x 36) SX3000-57-4
M3 x 48.5,
M2: 0.16 N·m
ARBY5000 Matt nickel plated SX5000-57-6 M3: 0.8 N·m

1-4-135
Base Mounted

Series SY3000/5000

Dimensions: Series SY5000


C4, N3
SS5Y5-45-AU- Stations D- C6, N7 (Pitch)
C8, N9 P=16 17 26 Button for DIN rail release
One-touch fitting (A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"

31.5

32
ø8, ø5/16"

14.5
A A A A A R

15.5
B B B B B P
One-touch fitting
P, R port With interface regulator (with gauge)
Applicable connector: 20 pins MIL type Applicable tubing O.D.: ø10, ø3/8"
(Pitch)
With strain releaf
(Conforming to MIL-C-83503) 12 41 L3 (L4) P=16 17 26 54.5 SV
Manual override
SZ

6
-+ -+

(3.5)
(4.9)
DIN rail

4
-+ -+

(87.2)
0 8
SY
44.2

44.2
42.5

41.2
8 1 9
31.6

2 10 B B B B B B B B
139.6

SYJ
5.5

3 11
127

4 12
5 13
35

31.2
6 14
42.5

CONNECTOR

SX

48.3

48.3
BOX 7 15 A A A A A A A A
VZ3000-106-1A
63.3

69.8
-+ -+ -+ -+ -+
DIN rail -+ -+ -+
5

LED for power supply holding screw ø15 42.7


L2 5
Power supply terminal (Rail mounting hole pitch: 12.5) 94.1
L1
(Light/Surge voltage suppressor) (Station n) (Station 1)
6

71.1
58.1

55.7
42.7
42.6

Block separation button


7.5

(Push type)

C4, N3
SS5Y5-45-AD- Stations U- C6, N7
C8, N9
Button for DIN rail release
(Pitch)
14.5

15.5

26 17 P=16 78
31.5
32

R A A A A A

P B B B B B

One-touch fitting
One-touch fitting (A, B port)
P, R port
Applicable tubing O.D.: Applicable tubing O.D.: ø4, ø5/32"
ø10, ø3/8" ø6, ø1/4"
(L4) ø8, ø5/16"
L3 41 12
DIN rail Power supply terminal
Manual override
6

-+
(4.9)
4

LED for power supply


(3.5)

-+

8
44.2

42.5
41.2
31.2 31.6

B B B B B
139.6

15 7 VZ3000-106-1A
5.5

BOX
CONNECTOR
14 6
127

13 5
35

12 4
42.5

11 3
48.3

A A A A A 10 2
63.3

9 1

8 0

- + - + - + - + - +
5

DIN rail Applicable connector: 20 pins MIL type


holding screw L2 5
(Rail mounting hole pitch: 12.5) With strain releaf
L1 (Conforming to MIL-C-83503)
(Station n) (Station 1)
(Light/Surge voltage suppressor)
Stations n 2 stations 3 4 5 6 7 8 9 10 11 12 13 14 15 16 stations
L1 160.5 185.5 198 210.5 235.5 248 260.5 273 298 323 348 360.5 373 398 410.5
0

L2 150 175 187.5 200 225 237.5 250 262.5 287.5 312.5 337.5 350 362.5 387.5 400
71.1

58.1
55.7

L3 84 100 116 132 148 164 180 196 212 246 262 278 294 310 326
42.7

42.6
7.5

L4 11.5 16 14.5 12.5 17 15.5 13.5 12 16.5 12 16.5 14.5 13 17.5 15.5
∗ Two SUP/EXH blocks are provided for models
Block separation button
with 11 stations or more.
(Push type)

1-4-137
Base Mounted

Series SY3000/5000

DIN Rail Manifold Exploded View


45- A
NA Type
i
U side D Bolts o
y
u
0

8
2
9
3
10
4
11
5
12
24V
6
DC
+ 13
7
14
-
15

t !0

r q
a Bolts

w
w
e
e
eas
CN rail rel
DI ton
but

b
C
SM

Block separation button

D side

Replacement Parts !1
Part no.
No. Description Note
SY3000 SY5000
•SY3000
(Metric size) (Inch size)
C4: With One-touch fitting for ø4 N3: With One-touch fitting for ø 5 32"
C6: With One-touch fitting for ø6 N7: With One-touch fitting for ø 1 4"
Manifold block For SY5000
q SX3000-50-1A- SX5000-50-1A-
assembly (Metric size) (Inch size)
C4: With One-touch fitting for ø4 N3: With One-touch fitting for ø5 32"
C6: With One-touch fitting for ø6 N7: With One-touch fitting for ø 1 4"
C8: With One-touch fitting for ø8 N9: With One-touch fitting for ø 5 16"
(Gasket 10 is supplied as an accessory.)
(Metric size) (Metric size) P, R port SY3000 (Metric size) With One-touch fitting for ø8
SUP/EXH block SX3000-51-1A SX3000-51-1A (Inch size) With One-touch fitting for ø 5 16"
w assembly (Inch size) (Inch size) P, R port SY5000 (Metric size) With One-touch fitting for ø10
SX3000-51-15A SX5000-51-15A (Inch size) With One-touch fitting for ø 3 8"
e End block assembly R SX3000-52-1A SX5000-52-1A For D side
r End block assembly L SX3000-53-1A SX5000-53-1A For U side
t Connector box VZ3000-106-1A For 24 VDC only
y Rail stopper TXE1-SMC Made by Kasuga Electric Works, Ltd.
Type D, 2 to 8 stations
SY3000-43-1A- SY3000-43-2A- +COM Type U, 9 to 16 stations

Type D, 9 to 16 stations
SY3000-43-2A- SY3000-43-3A- +COM Type U, 2 to 8 stations
u Connector assembly
Type D, 2 to 8 stations
SY3000-43-1NA- SY3000-43-2NA- –COM Type U, 9 to 16 stations
Type D, 9 to 16 stations
SY3000-43-2NA- SY3000-43-3NA- –COM Type U, 2 to 8 stations
i Dust cap VZ3000-63-2
Round head M3 x 26,
o SY3000-23-4
combination screw Matt nickel plated
!0 Gasket SX3000-57-4 SX5000-57-6
!1 DIN rail VZ1000-11-1- Refer to page 1-4-123.

1-4-138
Base Mounted

Series SY3000/5000

How to Increase Manifold Base Station expansion is possible at any position.

1 Loosen bolt a fixing the manifold base until it begins to turn idly.
(While pressing DIN rail releasing buttons c , at two locations,
separate the manifold base from the DIN rail.)

2 Press manifold block assembly dividing button b , that are at the Fig. (1) Block mounting procedure
location where manifold bases are to be added, until button b
locks, and then separate the block assemblies.
3 Mount additional manifold block assembly on the DIN rail as
shown in the Fig. (1). SV
4 Press the block assemblies until a click sound is produced, and
tighten the bolts a to fix them to the DIN rail. SZ
Caution (Tightening torque: 1.4 N·m)
(While lightly holding the blocks after fixing an end block on one SY
side, tighten the other end block for better sealing.) Hook the DIN rail here
and press down in the
direction of the arrow
SYJ
5 Untighten the rail stopper bolt d to demount the connector box
until a click sound is
from the DIN rail, and when remounting it, tighten the bolt while
pressing it against the rail.
heard. SX
Caution
Note 1) When there are 10 or fewer manifold block assemblies, and more are
added to make a total of 11 or more, a supply/exhaust block assembly
must also be added.
Note 2) When disassembly and assembly are performed, air leakage may
result if connections between blocks and tightening of the end block’s
holding screw, is inadequate. Before supplying air, confirm that there
are no gaps, etc. between blocks, and that manifold blocks are
securely fastened to the DIN rail. Then supply air and confirm that
there is no air leakage before operating.
Note 3) One connector assembly is necessary for one solenoid.
When a number is necessary for the connector assembly mark tube,
suffix the number to the part no. (0 to 15 are provided as mark tube
numbers.)
Ex) +COM spec.: D type for 2 to 8 stations: No. 10
SY3000-43-1A-10

How to Change Fitting Assembly

Type 45 manifold permits change in the A and B port sizes by


changing the manifold block fitting assembly.
After removing the valve, remove the clip with a screwdriver, etc. For
mounting a new fitting assembly, insert it and then insert a clip until it
will not come out of the manifold block. Clip

Fitting Assembly Part No.


Metric size
One-touch fitting for ø4 VVQ1000-50A-C4
SY3000
One-touch fitting for ø6 VVQ1000-50A-C6
One-touch fitting for ø4 VVQ1000-51A-C4
SY5000 One-touch fitting for ø6 VVQ1000-51A-C6
One-touch fitting for ø8 VVQ1000-51A-C8
Inch size
One-touch fitting for ø5 32" VVQ1000-50A-N3 Fitting assembly
SY3000
One-touch fitting for ø 1 4" VVQ1000-50A-N7
One-touch fitting for ø5 32" VVQ1000-51A-N3
SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust. O ring
Otherwise, air leakage may result.

1-4-139
SY3000/5000
Series
Base Mounted Monifold
Stacking Type/DIN Rail Mounted
Type 45 Plug-in
How to Order Manifold How to Order Valve Manifold Assembly
Type 45F (D-sub connector, 25 pins)
Example (Type 45F/D-sub connector (25 pins))
SS5Y 3 45 F D 05 U C4 Double solenoid (24 VDC)
Single solenoid (24 VDC)
Series SY3140-5FU (2 sets)
SY3245-5FU (1 set)
3 SY3000 Blanking plate assembly
5 SY5000 SX3000-75-2A (1 set)

Common specifications
Nil Positive common
N Negative common

Us Sta
Connector mounting position ide tion
s ..
Symbol Mounting position ....
....
U U side ....
2
1
D D side
Ds Manifold base (5 stations)
ide
Valve stations SS5Y3-45FD-05D-C6
Symbol Stations Note
02 2 stations Single wining spec.
SS5Y3-45FD-05U-C6 1 set
...

...

(Applicable up to 20
20 20 stations solenoid valves.) (Type 45F, D-sub connector 5 port
manifold base part no.)
∗ This also includes the number of ∗ SX3000-75-2A 1 set (Blanking plate assembly part no)
blanking plate assemblies. ∗ SY3140-5FU 2 sets (Single solenoid part no.)
∗ Two stations are necessary for the ∗ SY3245-5FU 1 set (Double solenoid part no.)
double, 3 position (Dual body type). The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
SUP/EXH block assembly mounting position • The valve arrangement is numbered as the 1st. station from D side
Symbol Mounting position Stations regardless of the mounting position of connector box.
U U side 2 to 10 stations • When ordering double solenoid valves/3 position (Dual body type), please
D D side 2 to 10 stations keep in mind that they require two manifold stations.
B (Both sides) 2 to 20 stations
M Special specifications How to Order Valves (Type 45F, 45P, 45T, 45T1)
∗ For special specifications, indicate separately
on the manifold specification sheet.

A, B port size 2 position single SY 3 1 4 0 5 FU


One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Port size
C4 One-touch fitting for ø4
Applicable series Symbol Port size
N3 One-touch fitting for ø 5 32"
Applicable series Double, 3 position SY 3 2 4 5 5 FU
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000 Series
M Mixed M Mixed
3 SY3000
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
5 SY5000
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16" Type of actuation
M Mixed M Mixed 2 2 position double
∗ In the case of mixed specifications (M), indicate separately on the 3 3 position closed center
manifold specification sheet. 4 3 position exhaust center
Voltage 5 3 position pressure center
Nil 24 VDC
12V 12 VDC Dual body type (Double, 3 position)
Rated voltage
Option 5 24 VDC
When a longer DIN rail is desired than the specified 6 12 VDC
stations, specify the station number to be required.
(20 stations at maximum) Manual override
Nil Non-locking push type
For external pilot and built-in silencer, refer to page 1-4-197. D Push-turn locking slotted type
E Push-turn locking lever type

1-4-140
Base Mounted

Series SY3000/5000

How to Order Manifold


Type 45P (Flat ribbon cable)
SS5Y 3 45 P D 05 U C4 Option
When a longer DIN rail is desired than the
specified stations, specify the station number to be
Series required. (20 stations at maximum)
3 SY3000 Voltage
5 SY5000 Nil 24 VDC
12V 12 VDC
Common specifications A, B port size SV
Nil Positive common One-touch fitting (Metric size) One-touch fitting (Inch size)
N Negative common Symbol Port size Applicable series Symbol Port size Applicable series SZ
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
Connector poles C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
M Mixed M Mixed
SY
Symbol Poles Stations
Nil 26 2 to 20 stations C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
G 20 2 to 16 stations C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" SYJ
SY5000 SY5000
H 10 2 to 8 stations C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
M Mixed M Mixed SX
∗ In the case of mixed specifications, indicate separately on the manifold
Connector mounting position specification sheet.
Symbol Mounting position SUP/EXH block assembly mounting position
U U side
Symbol Mounting position Stations
D D side
U U side 2 to 10 stations
D D side 2 to 10 stations
B Both sides 2 to 20 stations
M Special specifications
∗ For special specifications, indicate separately
by the manifold specification sheet.
Valve stations (Blanking plate assemblies are included.)
26 pins (P) connector 20 pins (PG) connector 10 pins (PH) connector
Symbol Stations Note Symbol Stations Note Symbol Stations Note
02 2 stations Single wiring spec. 02 2 stations Single wiring spec. 02 2 stations Single wiring spec.
(Applicable up to 20
...

...

...

...

...

...

(Applicable up to 16 (Applicable up to 8
20 20 stations solenoid valves.) 16 16 stations solenoid valves.) 08 8 stations solenoid valves)
• Two stations are necessary for the double, 3 position (Dual body type).

Type 45T (9 pins terminal block) Type 45T1 (18 pins terminal block)

SS5Y 3 45T D 05 U C4 SS5Y 3 45T1 D 15 B C4


Series Series
Option Option
3 SY3000 3 SY3000
When a longer DIN rail is desired When a longer DIN rail is desired
5 SY5000 than the specified stations, specify
5 SY5000 than the specified stations, specify
the station number to be required. Terminal block mounting position the station number to be required.
Terminal block mounting position
Symbol Mounting position A, B port size Symbol Mounting position A, B port size
U U side One-touch fitting (Metric size) U U side One-touch fitting (Metric size)
D D side Symbol Port size Applicable series D D side Symbol Port size Applicable series
C4 One-touch fitting for ø4 C4 One-touch fitting for ø4
Valve stations C6 One-touch fitting for ø6 SY3000
Valve stations C6 One-touch fitting for ø6 SY3000
Symbol Stations Note M Mixed Symbol Stations Note M Mixed
02 2 stations C4 One-touch fitting for ø4 02 2 stations C4 One-touch fitting for ø4
Single wiring spec. Single wining spec.
...

...
...

...

(Applicable up to 8 solenoid valves) C6 One-touch fitting for ø6 (Applicable up to 17 solenoid valves.) C6 One-touch fitting for ø6
SY5000 17 17 stations SY5000
08 8 stations C8 One-touch fitting for ø8 C8 One-touch fitting for ø8
∗ This also includes the number of M Mixed ∗ This also includes the number of M Mixed
blanking plate assemblies. blanking plate assemblies.
One-touch fitting (Inch size) One-touch fitting (Inch size)
∗ Two stations are necessary for the ∗ Two stations are necessary for the
Symbol Port size Applicable series double, 3 position (Dual body type). Symbol Port size Applicable series
double, 3 position (Dual body type).
N3 One-touch fitting for ø 5 32" N3 One-touch fitting for ø 5 32"
SUP/EXH block assembly mounting position N7 One-touch fitting for ø 1 4" SY3000 SUP/EXH block assembly mounting position N7 One-touch fitting for ø 1 4" SY3000
Symbol Mounting position Stations M Mixed Symbol Mounting position Stations M Mixed
U U side 2 to 8 stations N3 One-touch fitting for ø 5 32" U U side 2 to 10 stations N3 One-touch fitting for ø 5 32"
D D side 2 to 8 stations N7 One-touch fitting for ø1 4" D D side 2 to 10 stations N7 One-touch fitting for ø 1 4"
SY5000 SY5000
B Both sides 2 to 8 stations N9 One-touch fitting for ø 5 16" B Both sides 2 to 17 stations N9 One-touch fitting for ø 5 16"
M Special specifications M Mixed M Special specifications M Mixed
∗ For special specifications, indicate separately ∗ In the case of mixed specifications (M), ∗ For special specifications, indicate separately ∗ In the case of mixed specifications (M),
by the manifold specification sheet. indicate separately on the manifold by the manifold specification sheet. indicate separately on the manifold
specification sheet. specification sheet.

Note) The terminal block (45T) manifold has no common polarity. It can be used for both positive and negative common.
1-4-141
Base Mounted

Series SY3000/5000

How to Order Manifold

Type 45G (Flat cable, PC wiring system compatible)

SS5Y 3 45G D 05 U C4
Series Option
3 SY3000 When a longer DIN rail is desired than
5 SY5000 the specified stations, specify the station
number to be required. (20 stations at
maximum)
Connector mounting position
Symbol Mounting position A, B port size
U U side One-touch fitting (Metric size) One-touch fitting (Inch size)
D D side Symbol Port size Applicable series Symbol Port size Applicable series
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
Valve stations M Mixed M Mixed
Symbol Stations Note C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
02 2 stations C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
Single wining spec. SY5000 SY5000
...

...

(Applicable up to 16 solenoid valves.) C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
16 16 stations M Mixed M Mixed
∗ Two stations are necessary for the double, 3 position ∗ In the case of mixed specifications, indicate separately on the
(Dual body type). manifold specification sheet.
∗ This also includes the number of blanking plate
assemblies. SUP/EXH block assembly specifications
Symbol Specifications
SUP/EXH block assembly Nil Internal pilot
mounting position R External pilot
S Internal pilot/Built-in silencer
Symbol Mounting position Stations
RS External pilot/Built-in silencer
U U side 2 to 10 stations
D D side 2 to 10 stations
B Both sides 2 to 16 stations
M Special specifications
∗ For special specifications, indicate
separately on the manifold
specification sheet.

1-4-142
Base Mounted

Series SY3000/5000

Manifold Specifications
D-sub connector Flat ribbon cable Type 45P Terminal block PCFlat ribbon cable
wiring system compatible
Model
Type 45P Type 45PG Type 45PH Type 45T Type 45T1
Type 45F Type 45G
Manifold Plug-in
P (SUP)/R (EXH) Common SUP, Common EXH
Valve stations Note 1, 2) 2 to 20 stations 2 to 16 stations 2 to 8 stations 2 to 17 stations 2 to 16 stations
A, B port Location Base
Porting specifications Direction Side
D-sub connector
SY3000 C8 (One-touch fitting for ø8)
P, R port
Port size
SY5000 C10 (One-touch fitting for ø10)
SV
A, B port
SY3000 C4 (One-touch fitting for ø4)/C6 (One-touch fitting for ø6)
SY5000 C4 (One-touch fitting for ø4)/C6 (One-touch fitting for ø6)/C8 (One-touch fitting for ø8)
D-sub connector Flat ribbon cable connector Flat ribbon cable connector Flat ribbon cable connector Flat ribbon cable connector SZ
Complies with Socket: 26 pins MIL type Socket: 20 pins MIL type Socket: 10 pins MIL type Terminal block Terminal block Socket: 20 pins MIL type
Applicable connector MIL-C-24308 with strain relief with strain relief with strain relief (M3) (M3) with strain relief
Flat ribbon cable JIS-X-5101 Conforming to MIL-C-83503 Conforming to MIL-C-83503 Conforming to MIL-C-83503 9 pins 18 pins Conforming to MIL-C-83503 SY
Internal wiring +COM (Type 45), –COM (Type 45N) In common between +COM and –COM. + COM
Manifold base SY3000
2 to 10 stations: W = 26n + 172 SYJ
weight w (g) 11 to 20 stations: W = 26n + 199
n: Stations 2 to 10 stations: W = 54n + 227
(D-sub connector) SY5000 11 to 20 stations: W = 52n + 264
SX
Note 1)For more than 11 stations, supply pressure to P port on both sides and exhaust from R port on both sides.
Terminal block Note 2)There is a limit depending on the number of solenoids. Refer to “How to Order”.

Flow Characteristics
Port size Flow characteristics
Model 1, 5, 3 4, 2 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB)
(P, EA, EB) (A, B) C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b Cv
SS5Y3-45 C8 C6 0.88 0.21 0.22 0.95 0.18 0.22
SS5Y5-45 C10 C8 2.2 0.24 0.53 2.5 0.18 0.58
Note) The value is for manifold base with 5 stations and individually operated 2 position type.

Manifold Option
 Blanking plate assembly  SUP block disk  Label for block disk
By installing a SUP block disk in The labels shown below are used on manifold stations containing
the pressure supply passage of a SUP/EXH block disk(s) to show their location. (3 pcs. each)
manifold valve, it is possible to VZ3000-123-1A (In common with SY3000/5000)
supply two or more different high Label for SUP block disk Label for EXH block disk Label for SUP/EXH block disk
Note)
Short cap and low pressures to one manifold.

Note) When a block disk is concurrently ordered by specifying on the manifold specification
sheet, etc., a label will be stuck on the position where block disk is mounted.
Series Part no.
 Silencer with One-touch fitting C
SY3000 SX3000-77-1A
SY5000 SX5000-77-1A The silencer plugs directly into the One- B
touch fittings of the manifold.
 EXH block disk
By installing an EXH block disk in the
A

exhaust passage of a manifold valve,


Series Assembly part no. it is possible to divide the valve’s
SY3000 SX3000-75-2A exhaust so that it does not affect Series Model Effective area A B C
SY5000 SX5000-76-6A another valve. (Two block disks are For SY3000 (ø8) AN203-KM8 14 mm2 ø16 26 51
needed to divide both exhausts.) AN200-KM10 26 mm2 ø22 53.8 80.8
Note)• When mounting For SY5000 (ø10)
blanking plate, be sure AN300-KM10 30 mm2 ø25 70 97
to mount a short cap.
ød

• Two stations are


 Plug (white)
øD

necessary for the These are inserted in unused cylinder ports and
double, 3 position (Dual Series Part no.
SUP, EXH ports. Purchasing order is available A
body type).
SY3000 SX3000-77-1A in units of 10 pieces. L
SY5000 SX5000-77-1A Dimensions
Applicable fittings size ød Model A L D
4 KQ2P-04 16 32 6
Caution 6 KQ2P-06 18 35 8
8 KQ2P-08 20.5 39 10
Mounting screw tightening torques 10 KQ2P-10 22 43 12
1 8" KQ2P-01 16 31.5 5
M2: 0.17 N·m
5 32" KQ2P-03 16 32 6
M3: 0.8 N·m
1 4" KQ2P-07 18 35 8.5
M4: 1.4 N·m
5 16" KQ2P-09 20.5 39 10

1-4-143
Base Mounted

Series SY3000/5000

Manifold Option

 D-sub connector (25 pins)/Cable assembly


015
AXT100-DS25- 030
050 L D-sub Connector Cable
44
Assembly Terminal No.
16 8 Terminal no. Lead wire color Dot marking
1 Black None
2 Brown None
3 Red None
1

14

4 Orange None
5 Yellow None
47.04

55

6 Pink None
7 Blue None
Approx. ø10 8 Purple White
25

Multi-core vinyl cable


13

0.3 mm2 x 25C 9 Gray Black


10 White Black
Terminal no. 11 White Red
Socket side 2-M2.6 x 0.45
12 Yellow Red
13 Orange Red
14 Yellow Black
D-sub Connector Cable Electric Characteristics 15 Pink Black
Cable Item Characteristics 16 Blue White
Assembly part no. Note
length (L) Conductor resistance 17 Purple None
65 or less
1.5 m AXT100-DS25-015 Ω/km, 20°C 18 Gray None
Cable 25 core 19 Orange Black
3m AXT100-DS25-030 Voltage limit
x 24 AWG 1000 20 Red White
5m AXT100-DS25-050 V, 1 min, AC
21 Brown White
∗ When a commercially available Insulation resistance 22 Pink Red
5 or more
connector is required, use a 25 MΩkm, 20°C 23 Gray Red
pin female connector conforming Note) The min. bending radius of D-sub 24 Black White
to MIL-C24308. cable assembly is 20 mm. 25 White None

Connector manufacturers’ example


• Hirose Electric Co., Ltd.
• Fujitsu Limited
• Japan Aviation Electronics Industry, Ltd.
• J.S.T. Mfg. Co., Ltd.

 Flat Ribbon Cable Connector/Cable assembly  Dimensions/DIN rail


1
AXT100-FC - to VZ1000 11 1
3
Refer to L dimensions
Triangle mark position ∗ Fill in  with an appropriate no. listed on the table of
Red DIN rail dimensions shown below.
W

Terminal
number L

Flat Ribbon Cable Assembly


Cable length (L) 10 pins 20 pins 26 pins No. 0 1 2 3 4 5 6 7 8 9 10
1.5 m AXT100-FC10-1 AXT100-FC20-1 AXT100-FC26-1 L Dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223
3m AXT100-FC10-2 AXT100-FC20-2 AXT100-FC26-2 No. 11 12 13 14 15 16 17 18 19 20 21
5m AXT100-FC10-3 AXT100-FC20-3 AXT100-FC26-3 L Dimension 235.5 248 260.5 273 285.5 298 310.5 323 335.5 348 360.5
Connector width (W) 17.2 30 37.5
No. 22 23 24 25 26 27 28 29 30 31 32
∗ For other commercial connectors, use a type with strain relief
L Dimension 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498
that conform to MIL-C-83503.
No. 33 34 35 36 37 38 39 40 41 42 43
Connector manufacturers’ example L Dimension 510.5 523 535.5 548 560.5 573 585.5 598 610.5 623 635.5
• Hirose Electric Co., Ltd. No. 44 45 46 47 48 49 50 51 52 53 54
• Sumitomo 3M Limited L Dimension 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773
• Fujitsu Limited
No. 55 56 57 58 59 60 61 62 63 64 65
• Japan Aviation Electronics Industry, Ltd.
• J.S.T. Mfg. Co., Ltd.
L Dimension 785.5 798 810.5 823 835.5 848 860.5 873 885.5 898 910.5
No. 66 67 68 69 70 71
L Dimension 923 935.5 948 960.5 973 985.5
∗ Refer to L1 dimension on pages starting with page 1-4-150 for lengths
that correspond to the number of manifold stations.

1-4-144
Base Mounted

Series SY3000/5000

Manifold Internal Wiring

Type 45(N)F: D-sub Connector


<For positive common (45F)> <For negative common (45NF)>
A D-sub connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.
Positive pole (common) Positive pole

Negative Pole Negative Pole (common) SV


Not use Not use

Light/surge
voltage
Station 20
Light/surge
voltage
Station 20 SZ
suppressor suppressor
Station 5 SOL. B (Double solenoid Station 5 SOL. B (Double solenoid
St
ati
}
Station 4 SOL. A Dual body type)
}
Station 4 SOL. A Dual body type)
SY
U on Light/surge Light/surge
sid s. voltage voltage
e .... suppressor suppressor
.2
1 Station 3 (Single solenoid) Station 3 (Single solenoid)
SYJ
Light/surge Light/surge
voltage voltage
suppressor Station 2 (Single solenoid) suppressor Station 2 (Single solenoid)

D Station 1 (Single solenoid) Station 1 (Single solenoid) SX


sid Light/surge
voltage
Light/surge
e suppressor
voltage
suppressor

Power supply terminal Power supply terminal

• The power source terminal is used for connecting to an external power source.
• The maximum number of stations that can be accommodated is 20 manifold stations, with up to 22
solenoids. (For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.

Type 45(N)P: Flat Ribbon Cable (26 pins)


<For positive common (45P)> <For negative common (45NP)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.
Positive pole (common) Positive pole
Negative pole Negative pole (common)

Not use Not use


Station 20 Station 20

Light/surge Light/surge
voltage voltage
suppressor suppressor

St
}
Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type) }
Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type)
U ati Light/surge Station 3 (Single solenoid) Station 3 (Single solenoid)
sid on voltage
Light/surge
voltage
e s. suppressor suppressor
....
.. 2 Light/surge Light/surge
1 voltage voltage
suppressor Station 2 (Single solenoid) suppressor Station 2 (Single solenoid)
Station 1 (Single solenoid) Station 1 (Single solenoid)
Triangle mark Triangle mark
D Light/surge Light/surge
sid voltage
suppressor voltage
e suppressor

Power supply terminal Power supply terminal

Note)
Terminal no. is not indicated
Triangle mark on the connector. The
terminal no. indicated in the • The power source terminal is used for connecting to an external power source.
connection schematic of • The maximum number of stations that can be accommodated is 20 manifold stations, with up to 20
connector, as shown in the solenoids. (For more stations, please contact SMC.)
reference, means a
correlation of 1, 2, 3····26
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
from the triangle mark side
on the flat ribbon cable of
Reference figure connector.

1-4-145
Base Mounted

Series SY3000/5000

Manifold Internal Wiring

Type 45(N)PG: Flat Ribbon Cable (20 pins) <For positive common (45PG)> <For negative common (45NPG)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.

Positive pole (common) Positive pole

Negative pole Negative pole (common)


Station 16 Station 16

Light/surge Light/surge
voltage voltage
suppressor Station 5 SOL. B (Double solenoid suppressor
Station 5 SOL. B (Double solenoid
St
ati
}
Station 4 SOL. A Dual body type) }
Station 4 SOL. A Dual body type)
on Light/surge
Station 3 (Single solenoid) Light/surge Station 3 (Single solenoid)
U s. voltage voltage
sid .... suppressor suppressor
....
e 2 Light/surge Light/surge
1 voltage voltage
suppressor Station 2 (Single solenoid) suppressor Station 2 (Single solenoid)
Station 1 (Single solenoid) Station 1 (Single solenoid)
Light/surge
Triangle mark Triangle mark
Light/surge
voltage voltage
D suppressor suppressor
sid
e

Power supply terminal Power supply terminal

Note)
Terminal no. is not
Triangle mark indicated on the connector.
The terminal no. indicated
in the connection
schematic of connector, as
shown in the reference,
• The power source terminal is used for connecting to an external power source.
means a correlation of 1, 2, • The maximum number of stations that can be accommodated is 16 manifold stations, with up to 16
3····20 from the triangle solenoids. (For more stations, please contact SMC.)
mark side on the flat ribbon • Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
Reference figure cable of connector.

Type 45(N)PH: Flat Ribbon Cable (10 pins) <For positive common (45PH)> <For negative common (45NPH)>
A flat cable connector used for electric wiring
reduces labor during wiring operation.
Connectors conforming to MIL are used for
interchangeability.

Positive pole (common) Positive pole


Negative pole Negative pole (common)
Station 8 Station 8

Light/surge Light/surge
voltage voltage
suppressor suppressor
}
Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type) }
Station 5 SOL. B (Double solenoid
Station 4 SOL. A Dual body type)
Light/surge
voltage
Station 3 (Single solenoid) Light/surge
voltage
Station 3 (Single solenoid)
St suppressor suppressor
ati
U on Light/surge Light/surge
sid s. voltage
Station 2 (Single solenoid) voltage Station 2 (Single solenoid)
e .... suppressor suppressor
.. 2
1 Station 1 (Single solenoid) Station 1 (Single solenoid)
Triangle mark Triangle mark
Light/surge Light/surge
voltage voltage
suppressor suppressor

D
sid
e

Note)
Terminal no. is not Power supply terminal Power supply terminal
Triangle mark indicated on the connector.
The terminal no. indicated
in the connection
schematic of connector, as
shown in the reference, • The power source terminal is used for connecting to an external power source.
means a correlation of 1, • The maximum number of stations that can be accommodated is 8 manifold stations, with up to 8 solenoids.
2, 3····10 from the triangle (For more stations, please contact SMC.)
mark side on the flat
ribbon cable of connector. • Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
Reference figure

1-4-146
Base Mounted

Series SY3000/5000

Manifold Internal Wiring

Type 45T: Terminal Block (45T)


A terminal block style permits direct cable
connection without treatment of lead wires.

Station 8
Light/surge
voltage
suppressor
SV
SZ
}
Light/surge Station 5 SOL. B
voltage
suppressor
(Double solenoid
Dual body type)
Light/surge
voltage
suppressor Station 4 SOL. A SY
St
ati
U
sid
on
s.
....
Light/surge
voltage
suppressor
Station 3 (Single solenoid) SYJ
e ....
2
1 Light/surge
voltage
suppressor Station 2 (Single solenoid) SX
D
sid Light/surge
Station 1 (Single solenoid)
e voltage
suppressor

Common (+, –)

• The maximum number of stations that can be accommodated is 8 manifold stations, with up to 8 solenoids.
(For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
• There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for
–COM spec.

Type 45T1: Terminal Block (45T1)

Station 17

Station 8
Light/surge
voltage
suppressor

St

}
ati Light/surge Station 5 SOL. B
on voltage
U s. suppressor
(Double solenoid
sid ....
e .... Dual body type)
2 Light/surge
1 voltage
suppressor Station 4 SOL. A

D Light/surge
sid voltage
suppressor
Station 3 (Single solenoid)
e
Light/surge
voltage
suppressor Station 2 (Single solenoid)

Light/surge
voltage Station 1 (Single solenoid)
suppressor

Station 9
Common (+, –)

• The maximum number of stations that can be accommodated is 17 manifold stations, with up to 17
solenoids. (For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as the 1st one.
• There is no polarity in the COM wiring. Supply positive power for +COM spec. and negative power for
–COM spec.

1-4-147
Base Mounted

Series SY3000/5000

Manifold Internal Wiring

Type 45G: Flat Ribbon Cable


(PC Wiring System compatible) Electric circuit diagram
(Below wiring is the case of all double solenoid connections.)
It’s the manifold for 20 pins flat ribbon cable
connector which is compliant for PC wiring
system. Cable connector for flat ribbon cable Terminal no.
SOL.A 20
1 station { SOL.B 18
SOL.A 16
2 stations { SOL.B 14
SOL.A 12
3 stations { SOL.B 10
SOL.A 8
4 stations { SOL.B 6
SOL.A 19
5 stations { SOL.B 17
SOL.A 15
Us
2
+C 4VD
- OM C
6 stations { SOL.B 13
e
ide +
typ
Sta W
Connector terminal number SOL.A 11
PC
tion 7 stations {
C
SM

s SOL.B 9
SOL.A 7
3 8 stations { SOL.B 5
2
1
Triangle mark position
3.4
D
sid
e 24 VDC –+
1.2

• The maximum number of stations that can be accommodated is 16 manifold stations, with
up to 16 solenoids. (For more stations, please contact SMC.)
• Regardless of the connector mounting position, stations are to be counted from D side as
the 1st one.
For details about the PC wiring system, refer to catalog
CAT.ES02-20 separately.

1-4-148
Base Mounted

Series SY3000/5000

How to Connect SS5Y-45 (Plug-in)

Power terminal is equipped with plug-in manifold of Series SY as standard.


Power terminal enables the power supply to valve from either of manifold or controller side.

1. Wiring example when using manifold power supply terminals

SY manifold internal wiring


(Flat ribbon cable, plus common specifications)
Controller side (PLC, etc.) SV
(NPN open collector output)
PLC
SZ
Negative pole

SY
Manifold valve
(SS5Y3-45PGD-05U-) SYJ
SX

DC power supply

Solenoid valve
Power Triangle Cable assembly
supply mark AXT100-FC20-, etc.
terminal

Power supply

2. Wiring example when not using manifold power supply terminals


(Power is supplied to the controller side or along the wiring, etc.)

Power supply
SY manifold internal wiring
(Flat ribbon cable, plus common specifications)
Controller side (PLC, etc.)
PLC Positive pole (NPN open collector output)

Manifold valve
(SS5Y3-45PGD-05U-)

DC power supply

Solenoid valve
Power Triangle Cable assembly
supply mark AXT100-FC20-, etc.
terminal

Caution
• Single wire, COM position, etc. of PLC are different from each manufacturer. When
connecting with PLC, read the specifications carefully and understand the electrical
circuit. Poor wiring could cause damage to PLC, power source, etc. as well as manifold
and valve.

1-4-149
Base Mounted

Series SY3000/5000

SY5000: D-sub Connector/Plug-in


C4, N3
SS5Y5-45FU- Stations D- C6, N7
C8, N9
One-touch fitting (Pitch)
(A, B port) P = 16 17 26 Button for DIN rail release
Applicable tubing O.D.: ø4, ø5/32"

15.5
ø6, ø1/4"
31.5

32
ø8, ø5/16"

14.5
A A A A A R

B B B B B P Note) The L1 to L4 dimensions of SS5Y5-45FU-


C4, N3
One-touch fitting Stations U- C6, N7 are identical to those of
C8, N9 C4, N3
(P, R port) SS5Y5-45FU- Stations D- C6, N7 .
C8, N9
Applicable tubing O.D.: ø10, ø3/8"
U side (L4) D side
Equivalent to the applicable L3
D-sub connector {JIS-X-5101, MIL-C-24308}

(4.9)
(3.5)
27 M2.6
DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

31.2
A A A

24VDC
+COM
- +
Manual override
Depress and turn to operate
Terminal no. 1
L2 5
( and lock override. )
Power supply terminals A side: Orange
The voltage indication (Rail mounting hole pitch: 12.5)
(marking is for 24 VDC. ) L1 B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor)

M3 7
Terminal screw
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
71.1

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5


47.7

42.7
7.5

L2 125 137.5 150 175 187.5 200 225 237.5 250


L3 105 121 137 153 169 185 201 217 233
L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5
Block separation button
C4, N3 (Push type)
SS5Y5-45FU- Stations B- C6, N7 (Pitch) Button for DIN rail release
C8, N9 47 P = 16 17 26
15.5
14.5

31.5
32

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side (L4) D side
Equivalent to the applicable L3
(4.9)

D-sub connector {JIS-X-5101, MIL-C-24308}


(3.5)

27 M2.6
DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

31.2

A A A
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5
24VDC
+COM
L2 137.5 162.5 175 187.5 200 225 237.5 250 275
- +
L3 123 139 155 171 187 203 219 235 251
L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
Terminal no. 1 Power supply terminals Manual override
Press and turn to operate Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
is for 24 VDC. ) ( and lock override. )
The voltage indication
( marking L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
A side: Orange
B side: Green
L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
L2 5 L3 267 283 299 315 331 347 363 379 395 411
(Rail mounting hole pitch: 12.5) L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12
L1

1-4-152
Base Mounted

Series SY3000/5000

SY5000: D-sub Connector/Plug-in


C4, N3
SS5Y5-45FD- Stations U- C6, N7
C8, N9
26 17 (Pitch) 46 Button for DIN rail release
P = 16
14.5

31.5
32

15.5
R A A A A A

P B B B B B

One-touch fitting Note) The L1 to L4 dimensions of SS5Y5-45FD-


One-touch fitting C4, N3
(P, R port) (A, B port)Applicable tubing O.D.: ø4, ø5/32" Stations D- C6, N7 are identical to those of
C8, N9 C4, N3
SV
Applicable tubing O.D.: ø10, ø3/8" ø6, ø1/4" SS5Y5-45FD- Stations U- C6, N7 .
ø8, ø5/16" C8, N9
SZ
U side D side
L3 (L4) Equivalent to the applicable
D-sub connector {JIS-X-5101, MIL-C-24308}
SY
(4.9)

DIN rail holding screw


(3.5)

28
SYJ
DIN rail
8
41.2 SX
PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4
31.2

A A A

24VDC
+COM
- +

Manual override Power supply terminals


Terminal no. 1 M2.6
The voltage indication
Press and turn to operate
(
and lock override. ) L2
(Rail mounting hole pitch: 12.5)
5 ( marking is for 24 VDC. )
A side: Orange L1
B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor) Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 135.5 1 48 160.5 185.5 198 210.5 235.5 248 260.5
7 M3 L2 125 137.5 150 175 187.5 200 225 237.5 250
Terminal screw
L3 105 121 137 153 169 185 201 217 233
71.1

L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


47.6
42.7

7.5

Block separation button


C4, N3 (Push type)
SS5Y5-45FD- Stations B-C6, N7
C8, N9

26 (Pitch) 17 47 Button for DIN rail release


P = 16
15.5
31.5

32
14.5

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"

DIN rail holding screw U side L3 (L4) D side Equivalent to the applicable
DIN rail D-sub connector {JIS-X-5101, MIL-C-24308}
(4.9)
(3.5)

28
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
8 L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5
19.4 41.2

L2 137.5
PORT

PORT

B B
162.5 175 187.5 200 225 237.5 250 275
5.5
35

L3 123 139 155 171 187 203 219 235 251


SOL.a

SOL.a
SOL.b

SOL.b
114.3

L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17


110.4
31.2

A A A
Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
24VDC
L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
+COM
- +
L3 267 283 299 315 331 347 363 379 395 411
L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12
Manual override Terminal no. 1 M2.6 Power supply terminals
Press and turn to operate L2 5
(and lock override. ) (Rail mounting hole pitch: 12.5) ( The voltage indication
marking is for 24 VDC. )
A side: Orange L1
B side: Green

1-4-153
Base Mounted

Series SY3000/5000

SY5000: Flat Ribbon Cable/Plug-in


C4, N3
SS5Y5-45PU- Stations D- C6, N7 (26 pins)
C8, N9 (Pitch) 17 26 Button for DIN rail release
P = 16

15.5
31.5

32
14.5
A A A A A R

B B B B B P

One-touch fitting
One-touch fitting Note) The L1 to L4 dimensions of SS5Y5-45PU-
(P, R port) Stations U- C6,
C4, N3
N7 are identical to those of
(A, B port)
Applicable tubing O.D.: ø10, ø3/8" C8, N9 C4, N3
Applicable tubing O.D.: ø4, ø5/32" SS5Y5-45PU- Stations D- C6, N7 .
ø6, ø1/4" C8, N9

ø8, ø5/16"
U side D side
Applicable connector: 26 pins MIL type L3 (L4) Applicable connector: Applicable connector:
With strain releaf 20 pins MIL type 10 pins MIL type

(4.9)
(3.5)
(Conforming to MIL-C-83503) 28.9 (Conforming to (Conforming to
DIN rail holding screw MIL-C-83503) MIL-C-83503)
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a
SOL.b
SOL.a
SOL.b

Triangle mark
114.3

19.4
110.4

position

31.2
Triangle mark
A A A position

24VDC 24VDC 24VDC


+COM +COM +COM
– + – + – +

Triangle mark position Manual override


Power supply terminals Type 45PG (20 pins) Type 45PH (10 pins)
The voltage indication L2 5 Depress and turn to operate
(and lock override. )
(marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
A side: Orange
L1
B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor)

M3
Terminal screw
71.1

7 Stations n 2 stations 3 4 5 6 7 8 9 10 stations


47.7

42.7

L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5


7.5

L2 125 137.5 150 175 187.5 200 225 237.5 250


L3 105 121 137 153 169 185 201 217 233
Block separation button L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5
(Push type)
C4, N3
SS5Y5-45PU- Stations B- C6, N7 (26 pins)
C8, N9 (Pitch)
47 P = 16 17 26 Button for DIN rail release
14.5

15.5
31.5
32

R A A A A A R

P B B B B B P

One-touch fitting
One-touch fitting (P, R port)
Applicable tubing O.D.: ø10, ø3/8"
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side D side
L3 (L4)
Applicable connector: 26 pins MIL type
(4.9)
(3.5)

With strain releaf


28.9
(Conforming to MIL-C-83503) DIN rail holding screw
8 DIN rail
41.2

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


PORT

PORT

B B
5.5

L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5


35

SOL.a

SOL.a
SOL.b

SOL.b

L2 137.5 162.5 175 187.5 200 225 237.5 250 275


114.3

19.4
110.4

31.2

A A A
L3 123 139 155 171 187 203 219 235 251
L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
Manual override Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
Press and turn to operate L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
( )
24VDC
+COM
– +
and lock override. L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
A side: Orange
Power supply terminals Triangle mark position B side: Green
L3 267 283 299 315 331 347 363 379 395 411
The voltage indication L2 5 L4 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12
(marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L1

1-4-156
Base Mounted

Series SY3000/5000

SY5000: Flat Ribbon Cable/Plug-in


C4, N3
SS5Y5-45PD- Stations U- C6, N7 (26 pins)
C8, N9
26 17 (Pitch) 46 Button for DIN rail release
P = 16

15.5
14.5

31.5
32

R A A A A A

P B B B B B
Note) The L1 to L4 dimensions of SS5Y5-45PD-
C4, N3
One-touch fitting One-touch fitting Stations D- C6, N7 are identical to those of
C8, N9 C4, N3
SV
(P, R port) (A, B port) SS5Y3-45PD- Stations U- C6, N7 .
C8, N9
Applicable tubing O.D.: Applicable tubing O.D.: ø4, ø5/32"
ø10, ø3/8" ø6, ø1/4" SZ
ø8, ø5/16"

U side L3 (L4) D side


SY
DIN rail holding screw
(4.9)

Applicable connector: 26 pins MIL type


(3.5)

DIN rail
28 With strain releaf SYJ
(Conforming to MIL-C-83503)
8 SX
41.2
PORT

PORT

B B
5.5
35

SOL.a
SOL.a

SOL.b
SOL.b

Triangle mark position


114.3

19.4
110.4
31.2

A A A

24VDC
+COM
– +

Power supply terminals


Manual override
The voltage indication
( Press and turn to operate
and lock override. ) (Rail mounting hole pitch: 12.5)
L2 5
( marking is for 24 VDC. )
A side: Orange L1
B side: Green (Station n) (Station 1) Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(Light/Surge voltage suppressor) L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5
L2 125 137.5 150 175 187.5 200 225 237.5 250
M3 L3 105 121 137 153 169 185 201 217 233
Terminal screw
L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5
71.1

47.6
42.7

7.5

C4, N3
SS5Y5-45PD- Stations B-C6, N7 (26 pins) Block separation button
C8, N9 (Push type)
(Pitch)
26 P = 16 17 47 Button for DIN rail release
14.5
15.5
31.5

32

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side L3 (L4) D side
DIN rail holding screw Applicable connector: 26 pins MIL type
(4.9)
(3.5)

28 With strain releaf


DIN rail
(Conforming to MIL-C-83503)
8
19.4 41.2

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


PORT

PORT

B B
5.5

L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5


35
SOL.a

SOL.a
SOL.b

SOL.b

L2 137.5 162.5 175 187.5 200 225 237.5 250 275


114.3

110.4
31.2

A A A
L3 123 139 155 171 187 203 219 235 251
L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations
24VDC
+COM
– +
L1 298 310.5 323 348 360.5 373 398 410.5 423 435.5
L2 287.5 300 312.5 337.5 350 362.5 387.5 400 412.5 425
Manual override Triangle mark position Power supply terminals L3 267 283 299 315 331 347 363 379 395 411
Press and turn to operate
(and lock override. ) (Rail mounting hole pitch: 12.5)
L2 5 The voltage indication L4 15.5
( marking is for 24 VDC.) 13.5 12 16.5 14.5 13 17.5 15.5 14 12
A side: Orange
B side: Green L1

1-4-157
Base Mounted

Series SY3000/5000

SY5000: 9 Pins Terminal Block/Plug-in


C4, N3
SS5Y5-45TU- Stations D- C6, N7 (9 pins) 17 26 Button for DIN rail release
C8, N9
(Pitch) P=16

15.5

14.5
31.5

32
A A A A A R

One-touch fitting
B B B B B P

One-touch fitting (P, R port) Note) The L1 to L4 dimensions of SS5Y5-45TU-


(A, B port) Applicable tubing O.D.: ø10, ø3/8" C4, N3 C4, N3
Applicable tubing O.D.: ø4, ø5/32" Stations U- C6, N7 , SS5Y5-45TD- Stations U- C6, N7,
ø6, ø1/4"
U side
L3 (L4) D side C8, N9 C8, N9 SV
ø8, ø5/16" M3 C4, N3

(4.9)
DIN rail holding screw SS5Y5-45TD- Stations D-C6, N7 are identical those

(3.5)
27.5
Terminal screw DIN rail
C8, N9
C4, N3
SZ
of SS5Y5-45TU- Stations D- C6, N7.
C8, N9
8
SY

41.2
PORT

PORT
B B
5.5

SYJ
35

SOL.a

SOL.a
SOL.b

SOL.b
7

7
114.3

110.4
31.2
6

6
5

A A A

SX
4

4
3

3
6

2
1 COM

COM 1

Manual override
Press and turn to operate
(and lock override. )
A side: Orange
B side: Green
L2 5
(Rail mounting hole pitch: 12.5)
L1
(Station n) (Station 1) (Light/Surge voltage suppressor)

Stations n 2 stations 3 4 5 6 7 8 stations


71.1
71.4

L1 135.5 148 160.5 185.5 198 210.5 235.5


42.7
7.5

L2 125 137.5 150 175 187.5 200 225


L3 105 121 137 153 169 185 201
L4 15 13.5 11.5 16 14.5 12.5 17
Block separation button
C4, N3 (Push type)
SS5Y5-45TU- Stations B- C6, N7 (9 pins) (Pitch)
C8, N9 Button for DIN rail release
P=16 17 26
47 Note) The L1 to L4 dimensions of SS5Y5-45TD-
15.5
14.5

31.5
32

C4, N3
R A A A A A R Stations B- C6, N7 are identical to those of
C8, N9
C4, N3
P B B B B B P
One-touch fitting SS5Y5-45TU- Stations B-C6, N7.
C8, N9
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
U side (L4) D side ø8, ø5/16"
L3
(3.5)
(4.9)

27.5 M3 DIN rail holding screw


Terminal screw DIN rail
8
41.2
PORT

PORT

B B
5.5

8
35

SOL.a

SOL.a
SOL.b

SOL.b
7

7
114.3

110.4
31.2
6

6
5

A A A
4

4
3

3
2

2
1 COM

COM 1

Manual override Stations n 2 stations 3 4 5 6 7 8 stations


Press and turn to operate
(and lock override. ) L1 148 173
L2 137.5 162.5
185.5
175
198
187.5
210.5
200
235.5 248
225 237.5
A side: Orange
B side: Green L3 123 139 155 171 187 203 219
L2 5 L4 12.5 17 15 13.5 11.5 16 14.5
(Rail mounting hole pitch: 12.5)
L1

1-4-159
Base Mounted

Series SY3000/5000

SY5000: 18 Pins Terminal Block/Plug-in


C4, N3
SS5Y5-45T1U- Stations D- C6, N7 (18 pins)
C8, N9
One-touch fitting Button for DIN rail release
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
ø6, ø1/4" P=16 17 26 Note) The L1 to L4 dimensions of SS5Y5-45T1U-
ø8, ø5/16" C4, N3
Stations U- C6, N7 are identical to those of

14.5
15.5 C8, N9
31.5
C4, N3
SS5Y5-45T1U- Stations D- C6, N7 .

32
A A A A A R C8, N9

B B B B B P

One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
L3 (L4)
U side D side
48.5

(4.9)
(3.5)
27.5

41.2
PORT

PORT

B B
5.5

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2
6

6
5

A A A
4

DIN rail
3

3
6

2
1 COM

COM 1

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


L1 160.5 173 185.5 198 223 235.5 248 273 285.5
M3 Manual override L2 150 162.5 175 187.5 212.5 225 237.5 262.5 275
DIN rail holding screw Press and turn to operate
Terminal screw
(and lock override. ) L3 126
L4 17
142
15.5
158
13.5
174
12
190
16.5
206
14.5
222
13
238
17.5
254
15.5
A side: Orange
B side: Green
L2 5
(Rail mounting hole pitch: 12.5)
L1
(Station n) (Station 1)
(Light/Surge voltage suppressor)
Block separation button
(Push type)
80.9

71.1
71.4

42.7
7.5

C4, N3
SS5Y5-45T1U- Stations B- C6, N7 (18 pins) (Pitch)
Button for DIN rail release
C8, N9 68 P=16 17 26
15.5
14.5

31.5
32

R A A A A A R

P B B B B B P
One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
U side L3 (L4) D side ø6, ø1/4"
48.5 ø8, ø5/16"
(4.9)
(3.5)

27.5

8
41.2
PORT

PORT

B B
5.5

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17
8

8
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4

Stations n 2 stations 3 4 5 6 7 8 9 stations


31.2
6

L1 173 185.5 210.5


5

A A A
223 235.5 248 273 285.5
DIN rail
4

L2 162.5 175 200 212.5 225 237.5 262.5 275


3

3
2

L3 144 160 176 192 208 224 240 256


1 COM

COM 1

L4 14.5 17 15.5 13.5 12 16.5 14.5


Stations n 10 stations 11 12 13 14 15 16 17 stations
DIN rail holding screw M3 Manual override
Press and turn to operate L1 298 323 335.5 348 360.5 385.5 398 410.5
Terminal screw
(and lock override. ) L2 287.5 312.5 325 337.5 350 375 387.5 400
A side: Orange L3 272 288 304 320 336 352 368 384
L2 B side: Green 5 L4 13 17.5 15.5 14 12 16.5 15 13
(Rail mounting hole pitch: 12.5)
L1

1-4-162
Base Mounted

Series SY3000/5000

SY5000: 18 Pins Terminal Block/Plug-in


C4, N3
SS5Y5-45T1D- Stations U- C6, N7 (18 pins)
C8, N9
26 17 (Pitch) 67 Button for DIN rail release
P=16

15.5
Note) The L1 to L4 dimensions of SS5Y5-45T1D-
14.5

31.5
C4, N3
42.7

R A A A A A Stations D- C6, N7 are identical to those of


C8, N9
C4, N3
B B B B SS5Y5-45T1D- Stations U- C6, N7.
P
C8, N9
B

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32" SV
ø6, ø1/4"
L3 (L4) ø8, ø5/16"
U side
48.5
D side SZ
(4.9)
(3.5)

DIN rail holding screw 27.5


DIN rail SY
8

41.2
SYJ
PORT

PORT

B B
5.5
35

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17 8

8
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
SX
31.2

6
5

A A A
4

4
3

3
2

2
1 COM

COM 1

6
Manual override M3
Press and turn to operate Terminal screw
( and lock override. )
A side: Orange
B side: Green
L2 5
(Rail mounting hole pitch: 12.5)
L1
(Station n) (Station 1)
(Light/Surge voltage suppressor)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 160.5 173 185.5 198 223 235.5 248 273 285.5
L2 150 162.5 175 187.5 212.5 225 237.5 262.5 275
80.9

L3 126 142 158 174 190 206 222 238 254


71.1

71.4

L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5


42.7
7.5

C4, N3 Block separation button


SS5Y5-45T1D- Stations B- C6, N7 (18 pins) (Push type)
C8, N9
(Pitch)
26 P=16 17 68 Button for DIN rail release
15.5

14.5
31.5

32

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (P, R port)
ø6, ø1/4" Applicable tubing O.D.: ø10, ø3/8"
ø8, ø5/16" (L4)
L3
U side D side
(4.9)

48.5
(3.5)

DIN rail holding screw 27.5


DIN rail 8
41.2
PORT

PORT

B B
5.5
35

17 16 15 14 13 12 11 10 9

9 10 11 12 13 14 15 16 17 8

8
SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
31.2

6
5

A A A
4

Stations n 2 stations 3 4 5 6 7 8 9 stations


3

3
2

L1 173 185.5 210.5 223 235.5 248 273 285.5


1 COM

COM 1

L2 162.5 175 200 212.5 225 237.5 262.5 275


L3 144 160 176 192 208 224 240 256
Manual override M3 L4 14.5 12.5 17 15.5 13.5 12 16.5 14.5
Press and turn to operate Terminal screw
( and lock override. ) Stations n 10 stations 11 12 13 14 15 16 17 stations
A side: Orange L1 298 323 335.5 348 360.5 385.5 398 410.5
B side: Green L2 287.5 312.5 325 337.5 350 375 387.5 400
L2 5 L3 272 288 304 320 336 352 368 384
(Rail mounting hole pitch: 12.5)
L4 13 17.5 15.5 14 12 16.5 15 13
L1

1-4-163
Base Mounted

Series SY3000/5000

SY5000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)


C4, N3
SS5Y5-45GU- Stations D- C6, N7 (Pitch)
Button for DIN rail release
C8, N9 P = 16 17 26

15.5
31.5

32
Note) The L1 to L4 dimensions of SS5Y5-45GU-

14.5
A A A A A R

C4, N3
G Stations U- C6, N7 are identical to those of
B B B B B P C8, N9
One-touch fitting C4, N3
One-touch fitting (P, R port) SS5Y5-45GU- Stations D- C6, N7 .
C8, N9
(A, B port) Applicable tubing O.D.: ø10, ø3/8"
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side D side
L3 (L4)
Applicable connector: 20 pins MIL type

(4.9)
(3.5)
With strain releaf 28.9
(Conforming to MIL-C-83503) DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
PCW type

5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
23.2

31.2
A A A

24VDC
+COM
- +
Manual override
Press and turn to operate
Power supply terminals Triangle mark position ( and lock override. )
The voltage indication A side: Orange
(marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L2 5 B side: Green

L1

(Light/Surge voltage suppressor) (Station n) (Station 1)


Stations n 2 stations 3 4 5 6 7 8 9 10 stations
M3
L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5
Terminal screw L2 125 137.5 150 175 187.5 200 225 237.5 250
L3 105 121 137 153 169 185 201 217 233
71.1

7 L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


47.7

42.7
7.5

C4, N3 Block separation button


SS5Y5-45GU- Stations B- C6, N7 (Push type)
C8, N9 (Pitch)
47 P = 16 17 26 Button for DIN rail release
14.5

31.5
32

15.5

R A A A A A R

G
P B B B B B P

One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
U side ø8, ø5/16" D side
Applicable connector: 20 pins MIL type L3 (L4)
With strain releaf
(4.9)
(3.5)

(Conforming to MIL-C-83503) 28.9


DIN rail holding screw
8 DIN rail Stations n 2 stations 3 4 5 6 7 8 9 10 stations
41.2

L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5


PORT

PORT

B B
5.5

L2 137.5 162.5 175 187.5 200 225 237.5 250 275


35

SOL.a

SOL.a
SOL.b

SOL.b

L3 123 139 155 171 187 203 219 235 251


114.3
110.4
23.2

31.2

A A A L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17


Stations n 11 stations 12 13 14 15 16 stations
L1 298 310.5 323 348 360.5 373
24VDC
+COM
- + L2 287.5 300 312.5 337.5 350 362.5
L3 267 283 299 315 331 347
Power supply terminals Triangle mark position Manual override L4 15.5 13.5 12 16.5 14.5 13

(The voltage indication


marking is for 24 VDC. ) (Rail mounting hole pitch: 12.5)
L2 5 ( Press and turn to operate
and lock override. )
A side: Orange
L1 B side: Green

1-4-166
Base Mounted

Series SY3000/5000

SY5000: PC Wiring System Compatible (Flat ribbon cable/Plug-in)


C4, N3
SS5Y5-45GD- Stations U- C6, N7
C8, N9
26 17 (Pitch) P = 16 46 Button for DIN rail release

Note) The L1 to L4 dimensions of SS5Y5-45GD-


14.5

31.5
C4, N3
32

Stations D- C6, N7 are identical to those of

15.5
R A A A A A
C8, N9
C4, N3
P B B B B B
G
SS5Y5-45GD- Stations U- C6, N7.
C8, N9

One-touch fitting One-touch fitting SV


(P, R port)Applicable tubing O.D.: (A, B port)
ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4" SZ
ø8, ø5/16"
U side L3 (L4) D side SY
Applicable connector: 20 pins MIL type
(4.9)
(3.5)

DIN rail holding screw


26.1 With strain releaf SYJ
(Conforming to MIL-C-83503)
DIN rail
8
41.2 SX
PORT

PORT

B B

PCW type
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

110.4
23.2

Triangle mark position


31.2

A A A

24VDC
+COM
- +

Manual override Power supply terminals


L2 5 The voltage indication
Press and turn to operate
(and lock override. ) (Rail mounting hole pitch: 12.5) ( marking is for 24 VDC. )
A side: Orange L1
B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor) Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 135.5 148 160.5 185.5 198 210.5 235.5 248 260.5
M3
Terminal screw
L2 125 137.5 150 175 187.5 200 225 237.5 250
L3 105 121 137 153 169 185 201 217 233
71.1

7 L4 15 13.5 11.5 16 14.5 12.5 17 15.5 13.5


47.6
42.7

7.5

C4, N3 Block separation button


SS5Y5-45GD- Stations B- C6, N7 (Push type)
C8, N9
26 (Pitch) P=16 17 47 Button for DIN rail release
15.5
31.5

32
14.5

R A A A A A R

G
P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side L3 (L4) D side
DIN rail holding screw Applicable connector: 20 pins MIL type
(4.9)
(3.5)

26.1 With strain releaf


DIN rail
(Conforming to MIL-C-83503)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
8
23.2 41.2

L1 148 173 185.5 198 210.5 235.5 248 260.5 285.5


PORT

PORT

B B
5.5

L2 137.5 162.5 175 187.5 200 225 237.5 250 275


35

L3 123
SOL.a

SOL.a
SOL.b

SOL.b

139 155 171 187 203 219 235 251


114.3

110.4
31.2

A A A
L4 12.5 17 15 13.5 11.5 16 14.5 12.5 17
Stations n 11 stations 12 13 14 15 16 stations
L1 298 310.5 323 348 360.5 373
24VDC
+COM
- +
L2 287.5 300 312.5 337.5 350 362.5
L3 267 283 299 315 331 347
Manual override Triangle mark position Power supply terminals L4 15.5 13.5 12 16.5 14.5 13
The voltage indication
Press and turn to operate
(and lock override. ) (Rail mounting hole pitch: 12.5)
L2 5 ( marking is for 24 VDC. )
A side: Orange
B side: Green L1

1-4-167
Base Mounted

Series SY3000/5000

DIN Rail Manifold Exploded View


Type 45F (D-sub Connector) Manifold

r rail button
N
DI se y
U side c relea w

Posiotion when inserted


t a Bolts

e
l on
rai utt
b
b N
Block separation DI lease
button c re

Cover

D side
i
Replacement Parts
Part no.
No. Description Note
SY3000 SY5000
Manifold block assembly part number differs according to an attached lead wire assembly based on the connector spec. Select an
q Manifold block assembly appropriate part number from the table of manifold block assembly part number shown below. (Gasket 7 is supplied as an accessory.)
(Metric size) (Metric size) Metric size Inch size
w SUP/EXH block assembly SX3000-51-2A SX3000-51-2A SY3000: P, R port with One-touch fitting for ø8 With One-touch fitting for ø 5 16"
(Inch size) (Inch size) SY5000: P, R port with One-touch fitting for ø10 With One-touch fitting for ø 3 8"
SX3000-51-16A SX5000-51-16A
e End block assembly SX3000-52-2A SX5000-52-2A For D side
r End block assembly SX3000-53-2A SX5000-53-2A For U side
Connector block assembly 1A 1A -1A: +COM
t-1 (for D-sub connector)
SX3000-64-1NA SX5000-64- 1NA
-1NA: –COM
Connector block assembly 2A 2A
t-2 (for 26 pins flat cable)
SX3000-64- 2NA -26 SX5000-64- 2NA -26 Note)
Connector block assembly 2A 2A -2A: +COM For 24 VDC
t-3 (for 20 pins flat cable)
SX3000-64- 2NA -20 SX5000-64- 2NA -20 -2NA: –COM
Connector block assembly 2A 2A
t-4 (for 10 pins flat cable)
SX3000-64- 2NA -10 SX5000-64- 2NA -10
Connector block assembly
t-5 (for 2 to 8 stations (T, T1) terminal block)
SX3000-64-3A SX5000-64-3A
In common between +COM and –COM.
Connector block assembly
t-6 (for 9 to 17 stations (T1) terminal block)
SX3000-64-8A SX5000-64-8A
Round head M3 x 26,
y combination screw SY3000-23-4 Matt nickel plated
u Gasket SX3000-57-4 SX5000-57-6
i DIN rail VZ1000-11-1-l Refer to page 1-4-123.
Note 1) The numbers 5-1 to 4 are for 24 VDC. For 12 VDC, suffix “-12V” to the end of parts number. (Example) SX3000-64-1A-12 V
Note 2) Two manifold block assemblies are necessary for the double, 3 position (Dual body type).

Style of manifold Manifold block assembly part no. Note


For 45(N)F 3
:
SX 5 000-50-3A- AB port SY3000 (metric size) C4: With One-touch fitting for ø4
(D-sub connector)
C6: With One-touch fitting for ø6
P
For 45(N) PG (inch size) N3: With One-touch fittign for ø 5 32"
PH
(Flat ribbon cable) N7: With One-touch fitting for ø 1 4"
SX 35 000-50-5A- A, B port SY5000 (metric size) C4: With One-touch fitting for ø4
For 45G C6: With One-touch fitting for ø6
PC Wiring System compatible C8: With One-touch fitting for ø8
(inch size) N3: WIth One-touch fitting for ø 5 32"
For 45 TT1
SX 35 000-50-7A- N7: With One-touch fitting for ø 1 4"
(Terminal block) N9: With One-touch fitting for ø 5 16"

1-4-168
Base Mounted

Series SY3000/5000

How to Increase Manifold Base

1 Loosen bolt a fixing the manifold base until it begins to turn Fig. (1)
idly. (While pressing DIN rail releasing buttons c , at two
locations, separate the manifold base from the DIN rail.) Connector
mounting screw

2 Additional bases are to be added to the U side. Press splitting


button b of the manifold block assembly on the U side until
button b locks, and then separate the block assemblies. Fig. (2) Valve mounting
screw (2 pcs.)
SV
3 Separate the connector block assembly in the same manner as
2 , and remove the connector mounting screw shown in Fig. (1).
SZ
4 Loosen the valve mounting screw on the U side, remove the
SY
valve, and take out the receptacle housing. (Refer to Fig. (2).)

Cover SYJ
5 Insert the common wire (red) of the manifold block assembly to
be added into the pin insertion section (N mark) of the
receptacle housing that was taken out in 4 , mount it on the SX
manifold block, and mount the removed valve.
6 As shown in Fig. (3), mount the additional manifold block
Receptacle
assembly on the DIN rail on the U side. Refer to the circuit housing
diagram, and insert the lead wire (black) as shown in Fig. (4).
Fig. (3)

7 Press the blocks against each other until a click sound is Receptacle housing
produced, place the lead wire in the manifold block, and close
Pin insertion point
the lid without pinching the lead wire. N mark
Hook the DIN rail here and
press down in the direction
8 While lightly holding the blocks together so that there are no of the arrow until a click
gaps between them, secure them to the DIN rail by tightening sound is heard.
the screws a . (Tightening torque: 1.4 N·m)
Fig. (4)
D-sub connector (45F) Flat ribbon cable (45P) Terminal block (45 TT1)
Caution 1. Depending on the connector, there is a limit to the
number of solenoids that can be used. Manifold bases
that can be added cannot exceed the number of usable
solenoids.
2. The manifold block assembly mounting position for Connector
additional manifold bases is always on the U side, Connector
because wires are connected to respective connectors
sequentially from the D side.
3. When bolt a for the end block is not sufficiently
tightened during reassembly, air leakage may result.
Before supplying air, check that there is no gap
between blocks and that the manifold block is firmly Pin Tab terminal
fixed to the DIN rail in order to ensure air supply Pin
without leakage.
Note) Note) Note)
After inserting pins, Insert pins after removing Insert tab
lightly pull lead the connectorfrom the terminals
wiresto check that main unit. After inserting completely.
pins are locked. pins, lightly pull lead
wires to check that the
pins are locked.
Fitting Assembly
Clip
Type 45 manifold permits change in the A and B port sizes by
changing the manifold block fitting assembly.
After removing the valve, remove the clip with a screwdriver, etc. For
mounting a new fitting assembly, insert it and then insert a clip until it
will not come out of the manifold block.

Fitting Assembly Part No.


Metric size Inch size
One-touch fitting for ø4 VVQ1000-50A-C4 One-touch fitting for ø5 32" VVQ1000-50A-N3 Fitting assembly
SY3000 SY3000
One-touch fitting for ø6 VVQ1000-50A-C6 One-touch fitting for ø 1 4" VVQ1000-50A-N7
One-touch fitting for ø4 VVQ1000-51A-C4 One-touch fitting for ø5 32" VVQ1000-51A-N3
SY5000 One-touch fitting for ø6 VVQ1000-51A-C6 SY5000 One-touch fitting for ø 1 4" VVQ1000-51A-N7
One-touch fitting for ø8 VVQ1000-51A-C8 One-touch fitting for ø5 16" VVQ1000-51A-N9
Note 1) P and R ports cannot be changed.
Note 2) Use caution that O-rings must be free from scratches and dust. Otherwise,
O-ring
air leakage may result.

1-4-169
SY3000/5000
Series
Base Mounted Monifold
Stacking Type/DIN Rail Mounted
Type 45S Serial Transmission (Integrated)
How to Order Manifold How to Order Valve Manifold Assembly
Ordering example
SS5Y 3 45S A 05 U C6 Double solenoid (24 VDC) Single solenoid (24 VDC)
SY3245-5FU SY3140-5FU
Series
3 SY3000 Option U side
5 SY5000 When a longer DIN
Model rail is desired than
Symbol Specifications the specified
stations, specify the
0 Without SI unit
station number to be
A With general type SI unit (Series EX300) required.
Mitsubishi Electric Corp.: MELSECNET/ (Max. 20 stations) Sta
B tio
MINI-S3 Data Link System ns
A, B port size ....
....
C OMRON Corp.: SYSBUS Wire System .. 2
One-touch fitting (Metric size) 1
D SHARP Corp: Satellite I/O Link System
Symbol Port size Applicable
E Matsushita Electric Works: MEWNET-F System series
F1 NKE Corp.: Uni-wire System (16 outout points) One-touch
C4 fitting for ø4
Rockwell Automation: D side
G One-touch SY3000 Manifold base (5 stations)
Allen Bradley Remote I/O (RIO) System
C6 fitting for ø6
H NKE Corp.: Uni-wire H System SS5Y3-45SA-05U-C6
M Mixed
J1 SUNX Corp.: S-LINK System (16 output points) SS5Y3-45SA-05U-C6 1 set (Type 45S with serial unit 5
One-touch
J2 SUNX Corp.: S-LINK System (8 output points) C4 fitting for ø4 stations manifold base part no.)
K Fuji Electric Co.: T-LINK Mini System ∗ SY3140-5FU 3 sets (Single solenoid part no.)
One-touch ∗ SY3245-5FU 1 set (Double solenoid part no.)
C6 fitting for ø6
Q DeviceNet, CompoBus/D (OMRON Corp.) SY5000
OMRON Corp.: CompoBus/S System One-touch The asterisk. denotes the. symbol
. for assembly.
.
R1 C8 fitting for ø8
(16 output points) .
Prefix it to the part nos. of the solenoid valve, etc.
M Mixed ∗ The valve arrangement is numbered as the 1st. station from D
OMRON Corp.: CompoBus/S System
R2 One-touch fitting (Inch size) side.
(8 output points)
Applicable ∗ When ordering double solenoid valves/3 position (Dual body
U JEMANET (JPCN-1) Symbol Port size series type), please keep in mind that they require two manifold stations.
V Mitsubishi Electric Corp.: CC-LINK System One-touch ∗ Serial unit is available only for the D-side mounting type.
∗ For the general purpose type, a N3 fitting for ø5/32"
transmission unit is require on the CPU One-touch SY3000
side. N7 fitting for ø1/4" How to Order Valves
∗ Even though when it is not equipped with M Mixed
SI unit, DIN rail length is long enough for 2 position
future expectancy of mounting SI unit.
One-touch
N3 fitting for ø5/32"
single SY 3 1 4 0 5 FU
Valve stations One-touch
N7 fitting for ø1/4" Double
Symbol Stations
02 2 stations
Note
One-touch
SY5000
3 position SY 3 2 4 5 5 FU
N9 fitting for ø5/16"
Single wining spec. Series
...
...

(Applicable up to 16 solenoid valves.) M Mixed


16 16 stations ∗ In the case of mixed 3 SY3000 Rated
∗ This also includes the number of blanking specifications, indicate 5 SY5000 voltage
plate assemblies. separately on the 5 24 VDC
∗ Two stations are necessary for the double, 3 manifold specification Type of actuation
position (Dual body type). sheet. 2 2 position double
3 3 position closed center Dual body type
SUP/EXH block assembly mounting position 4 3 position exhaust center (Double,
Symbol Mounting position Stations 5 3 position pressure center 3 position)
U U side 2 to 10 stations
Manual override
D D side 2 to 10 stations
Nil Non-locking push type
B (Both sides) 2 to 16 stations
D Push-turn locking slotted type
M Special specifications
E Push-turn locking lever type
∗ For special specifications, indicate separately on the
manifold specification sheet.
SI Unit Part No.
Symbol Specifications For SS5Y-45S Symbol Specifications: For SS5Y-45S
A With general type SI unit (Series EX300) EX322-S001 J1 SUNX Corp.: S-LINK System (16 output points) EX122-SSL1
B Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System EX122-SMB1 J2 SUNX Corp.: S-LINK System (8 output points) EX122-SSL2
C OMRON Corp.: SYSBUS Wire System EX122-STA1 K Fuji Electric Co.: T-LINK Mini System EX122-SFU1
D SHARP Corp.: Satellite I/O Link System EX122-SSH1 Q Device Net: CompoBus/D (OMRON Corp.) EX122-SDN1
E Matsushita Electric Works: MEWNET-F System EX122-SPA1 R1 OMRON Corp.: CompoBus/S (16 output points) EX122-SCS1
F1 NKE Corp.: Uni-wire System (16 output points) EX122-SUW1 R2 OMRON Corp.: CompoBus/S (8 output points) EX122-SCS2
G Rockwell Automation: Allen Bradley Remote I/O (RIO) System EX122-SAB1 U JEMANET (JPCN-1) EX122-SJN1
H NKE Corp.: Uni-wire H System EX122-SUH1 V Mitsubishi Electric Corp.: CC-LINK System EX122-SMJ1

1-4-170
Base Mounted

Series SY3000/5000

 The serial transmission system reduces wiring work, while minimizing wiring and saving space.
 16 stations max. (Specify a model with more than 8 stations by using a manifold specification sheet.)
Type SB
Type SA
Mitsubishi Electric Corporation
Applicable to Series EX300
MELSECNET/MINI-S3 Data Link System

Name of terminal block, LED


Sta
tio
ns
....
U side .. 2
1
SV
LED Description LED Description
TRD Lights up when receiving data. POWER Lights up when power supply is ON.
D side RUN/ERR
Flashes when received data is normal;
RUN Lights up when the data transmission SZ
lights up when abnormal. with the master station is normal.
RD Lights up when receiving data.
SD Lights up when sending data. SY
Lights up when data reception error occurs;
The total number of stations is tabulated ERR. goes off when the error is corrected. SYJ
starting from station one on the D side.
Maximum station: Up to 16 solenoids (16 • Connection to T unit PLC manufacturer’s I/O • MELSECNET/MINI-S3 Data Link System
single solenoids). card enables serial transmission. Master unit: AJ71PT32-S3 SX
EX300-TMB1 For models of Mitsubishi Electric Corporation AJ71T32-S3
Note

EX300-TTA1 For models of OMRON Corporation A1SJ71PT32-S3


EX300-TFU1 For models of Fuji Electric Co., Ltd. ∗ No. of output points: 16 points,
EX300-T001 For general models No. of sta. occupied: 2 stations
∗ Up to 32 points per unit.
• No. of output points: 16 points
SI manifold solenoid valve
T unit OB unit SI unit SI unit Master unit Remote I/O unit Remote I/O unit
Cable wiring

Item Specifications
External power supply 24 VDC +10%/–5%
SA, SB, SD, SE, SF1, SG, SJ1,
Current consumption 0.1A
SJ2, SK, SR1, SR2, SH, SU, SV ∗ Ground either the reception side or the ∗ Ground either the reception side or the
(Internal unit)
0.3A SC, SQ transmission side of the shielding wire shield. transmission side of the shielding wire shield.

Type SC Type SD Type SE


OMRON Corporation SHARP Corporation Matsushita Electric Works, Ltd.
SYSBUS Wiring System Satellite I/O Link System MEWNET-F System
Name of terminal block, LED

LED Description LED Description LED Description


Lights up when transmission is normal POWER Lights up when power supply is ON. POWER Lights up when power supply is ON.
RUN and PLC is in operation mode. Lights up when power supply is ON and Flashes when sending and
RUN COMM.
T/R Flashes when transmission is normal; the slave unit is operating normally. receiving data.
ERR lights up when it is abnormal. Lights up in cases of abnormal slave unit switch Lights up when the unit is abnormal;
ERROR setting, abnormal communications, when the master ALARM flashes for setting error.
unit PLC has stopped or if the slave unit is defective.
R.SET Lights up when receiving the control
HOLD input from the master unit.

• SYSBUS Wire System • Satellite I/O Link System • MEWNET-F System


Master unit: Type C500-RM201 Master unit: ZW-31LM Master unit: AFP3740
Type C200H-RM201 JW-31LM AFP5740
Note

• No. of output points: 16 points JW-23LM • No. of output points: 16 points


• No. of output points: 16 points

a) 2-wire type
Wiring does not include signal ground line (SG).
Master station SI unit SI unit Master station Slave unit 01 Slave unit 02 Slave unit 75
Master station SI unit SI unit
Cable wiring

With shield
Twister pair wire
Type 3 ground Type 3 ground Type 3 ground Type 3 ground
a) 3-wire type
Wiring does not include signal ground line (SG).
Master station Slave unit 01 Slave unit 02 Slave unit 75
Type 3 ground Type 3 ground
Type 3 ground Type 3 ground
With shield
Twister pair wire
Type 3 ground Type 3 ground Type 3 ground Type 3 ground

1-4-171
Base Mounted

Series SY3000/5000

Type SF1 Type SG Type SJ1, SJ2


NKE Corporation Rockwell Automation, Inc. SUNX Corporation
Uni-wire System Allen Bradley Remote I/O (RIO) System S-LINK System
Name of terminal block, LED

LED Description LED Description LED Description


POWER Lights up when power supply is POWER Lights up when power supply is ON. POWER Lights up when power supply is ON.
ON. Lights up when communication is Transmission indicator:
Transmission indicator: COM. normal. Flashes when communication SEND Flashes when normal, flashes
SEND Flashes when normal; goes out is initialized. Goes out for abnormal slowly when abnormal.
or lights up when abnormal. communication.
ERROR Lights up for abnormal communication.
• Uni-wire System • Remote I/O (RIO) System • S-LINK System
Note

Send unit: SD-120 • No. of output points: 16 points S-LINK Controller: SL-CU1
• No. of output points: 16 points • No. of output points: 16 points (Type SJ1)
No. of output points: 8 points (Type SJ2)

a) Type T branching multi-drop b) Crossover wiring


Power
wiring (S-LINK System) (Sensor Link System)
supply

Power Master station SI unit SI unit


Cable wiring

Transmission line

supply

Black Brown
Terminal\ White Blue
Power register
supply Main Transmission line
Type 3 ground Type 3 ground Pressure connector SL-J1A
transmission
Power line
supply
The above is the example of using dedicated S-LINK
flat ribbon cable SL-RCMl00.

Type SK Type SR1, SR2


Type SDQ
Fuji Electric Co, Ltd. OMRON Corporation
DeviceNet CompoBus/S System
T Link Mini System
Name of terminal block, LED

LED Description LED Description LED Description


POWER Lights up when power supply is ON. POWER Green light is ON when the circuit is powered. Lights up when transmission is ON;
Goes out when SI unit is not online or POWER goes out when not powered.
Lights up for abnormal transmission
SEND the circuit is not powered.
or power off at the processor side. Lights up for normal communication;
Green light is continuously ON when COMM goes out for abnormal
SI unit is on-line and in operation. communication or waiting.
MOD/NET Red light flashes for connection time- Lights up for abnormal
out (minor communication error). communication; goes out for normal
ERR
Red light is continuously ON for connection communication or waiting.
time-out (major communication error) or
online impossibility.
• T Link Mini System • DeviceNet • CompoBus/S System
Master unit: FTM100B • OMRON Corporation: CompoBus/D System Master unit: C200HW-SRM21
Note

Converter: FRC100A-G02 Master station unit: C200HW-DSM21 Master unit: COM1-SRM21


Repeater: FRC200A-C10 • No. of output points: 16 points • No. of output points: 16 points (Type SR1)
• No. of output points: 16 points No. of output points: 8 points (Type SR2)

Master station Slave unit 01 Slave unit 03 Slave unit 04


Cable wiring

Master
With shield
terminal register
Connector with

Twister pair wire


Type 3 ground Type 3 ground Type 3 ground Type 3 ground

Connect the shielding wire to the SD terminal. If the shielding wire is Pressure connector
for distribution
not connected to the SD terminal, normal transmission will be
impossible even for short distances. Furthermore, do not ground the
shielding wire (SD).

1-4-172
Base Mounted

Series SY3000/5000

Type SH Type SV
Type SU
NKE Corporation Mitsubishi Electric Corporation
JEMANET (JPCN-1)
Uni-wire H System CC-LINK System

DIP.SW B RATE STATION NO.


ADDRESS
Name of terminal block, LED

0 1 0 1 0 1
POWERCOMM ALARM ON PW LRUN 9 9 9

2
1

O
N

8
ON

3
3
7

7
4 4 4
0 6 5 6 5 6 5
LERR. SD RD
POWER SEND

5
6
7
8
1
2
3
4
OFF x 10 x1

24V 0V D G D G 24V 0V 24V 0V A B SG FG 24V 0V 24V 0V +24V 24G DA DB DG FG

LED Description LED Description LED Description SV


Lights up when power supply is Lights up when SI unit power Lights up when transmission power;
POWER ON. (Lights on when normal; POWER supply is ON. PWR goes out when not powered.
flickers when voltage drops.
COMM
Lights up for normal Lights up when receiving SZ
Transmission indicator: flashes communication. L RUN normal data.
SEND when normal; goes out or lights Lights up for abnormal SD Lights up when sending data.
up when abnormal. ALARM
communication. RD Lights up when receiving data.
SY
Lights up for transmission error and
L ERR.
setting error; flashes when station SYJ
or transmission speed settings are
changed during operation.
SX
• Uni-wire H System • JEMA Net (JPCN-1) • CC-Link System
Send unit: SD-H2 (Reference) Master unit: AJ61BT11
• No. of output points: 16 points AJ71J92-S3 (Mitsubishi Electric Corporation) Master unit: A1SJ61BT11
Note

A1SJ71J92-S3 (Mitsubishi Electric Corporation) Master unit: AJ61QBT11


C200HW-JRM21 (OMRON Corporation) Master unit: A1SJ61QBT11
NJ-JPCN-1 (Fuji Electric Co., Ltd.) • No. of output points: 16 points
NP1L-JP1 (Fuji Electric Co., Ltd.)
• No. of output points: 16 points

a) 2-wire type
DG

Power 24V 24V


supply 0V 0V Slave unit Slave unit Slave unit
D Master station (SI unit) (SI unit) (SI unit)
G A A A A
D B B B B
G SG SG SG SG
Power 24V 24V FG FG FG FG
supply 0V 0V
With shield
OB unit
Cable wiring

Twisted pair wire Master unit OB unit


DA DA DA
Terminal Terminal
Transmission resistor
DB DB DB
resistor
DG DG DG
line SLD
FG
FG FG

With shield
a) 3-wire type Twisted pair wire
Type 3 ground Type 3 ground Type 3 ground
Power 24V 24V Slave unit Slave unit Slave unit
0V Master station (SI unit) (SI unit) (SI unit)
supply 0V
D A A A A
G B B B B
D SG SG SG SG
G FG FG FG FG
Power 24V 24V With shield
supply 0V 0V Twisted pair wire

DG

1-4-173
Base Mounted

Series SY3000/5000

Series SY5000: Serial Transmission Unit/Plug-in


C4, N3
SS5Y5-45S- Stations U- C6, N7
C8, N9
Button for (Pitch)

15.5
DIN rail release
26 17 P = 16 41

31.5
32
14.5

R A A A A A

P B B B B B

One-touch fitting One-touch fitting (A, B port)


(P, R port) Applicable tubing O.D.: ø4, ø5/32" SV
Applicable tubing O.D.: ø10, ø3/8" ø6, ø1/4"
ø8 , ø5/16"
DIN rail
holding screw
U side L3 (4.9) 28.8 9.3 (L4) D side SZ
(3.5)

DIN rail
8 M3 SY
Terminal screw
41.2

B B B SYJ
PORT

PORT

5.5

6.2
35

64
45
SOL.a

SOL.a
SOL.b

SOL.b

SX
114.3
110.4
31.2

A A A

Manual override
( Press and turn to operate
and lock override. )
A side: Orange
B side: Green
L2 5
(Rail mounting hole pitch: 12.5)
L1
(Light/Surge voltage suppressor) (Station n) (Station 1)
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 173 185.5 198 210.5 235.5 248 260.5 285.5 298
L2 162.5 175 187.5 200 225 237.5 250 275 287.5
L3 100 116 132 148 164 180 196 212 228
71.1

66.1

L4 17.45 15.7 13.95 12.2 16.7 14.95 13.2 17.7 15.95


42.7

7.5

Note) Width of SI unit applicable to “E”: Matsushita Electric


Works, Ltd. and “G”: Rockwell Automation, Inc. widens
to 24.3 mm . For further information, please consult
Block separation button
C4, N3 with SMC.
SS5Y5-45S- Stations B- C6, N7 Push type
C8, N9
Button for (Pitch)
15.5

DIN rail release 26 P = 16 17 42


31.5
32
14.5

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting (A, B port)


(P, R port) Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8"
ø6, ø1/4"
DIN rail U side L3 28.8 9.3 (L4) D side ø8, ø5/16"
holding screw
(4.9)
(3.5)

DIN rail
8
41.2

PORT

PORT

B B B
5.5

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


35

64
45
SOL.b
SOL.a

SOL.b
SOL.a

L1 185.5 198 223 235.5 248 260.5 285.5 298 310.5


114.3
110.4
31.2

A A A L2 175 187.5 212.5 225 237.5 250 275 287.5 300


L3 118 134 150 166 182 198 214 230 246
L4 14.7 12.95 17.45 15.7 13.95 12 16.5 14.95 13.2
Stations n 11 stations 12 13 14 15 16 stations
L1 335.5 348 360.5 373 398 410.5
Manual override L2 325 337.5 350 362.5 387.5 400
( Press and turn to operate
and lock override.
A side: Orange
) L3 262 278 294 310 326 342
L4 17.7 15.95 14.2 12.45 16.95 15.2
B side: Green
Note) Width of SI unit applicable to “E”: Matsushita Electric
L2 5 Works, Ltd. and “G”: Rockwell Automation, Inc. widens
(Rail mounting hole pitch: 12.5) to 24.3 mm . For further information, please consult
L1 with SMC.

1-4-175
SY3000/5000
Series
Base Mounted Monifold
Stacking Type/DIN Rail Mounted
Type 45S1 Serial Transmission (Separated)
How to Order Manifold

SS5Y 3 45S1 A D 05 U C4
Series Option
3 SY3000 When a longer DIN rail is desired than the specified
5 SY5000 stations, specify the station number to be required.
(Max. 20 stations)

A, B port size
Model One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Specifications Symbol Port size Applicable series Symbol Port size Applicable series
0 Without SI unit C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
A With general type SI unit (Series EX300) C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000
Mitsubishi Electric Corp.: MELSECNET/ M Mixed M Mixed
B
MINI-S3 Data Link System C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C OMRON Corp.: SYSBUS Wire System C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
D SHARP Corp: Satellite I/O Link System C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
E Matsushita Electric Works: MEWNET-F System M Mixed M Mixed
F1 NKE Corp.: Uni-wire System (16 outout points) ∗ In the case of mixed specifications, indicate separately on the manifold
Rockwell Automation: specification sheet.
G
Allen Bradley Remote I/O (RIO) System
H NKE Corp.: Uni-wire H System
J1 SUNX Corp.: S-LINK System (16 output points)
SUP/EXH block assembly
J2 SUNX Corp.: S-LINK System (8 output points)
mounting position
K Fuji Electric Co.: T-LINK Mini System
Symbol Mounting position Stations
Q DeviceNet, CompoBus/D (OMRON Corp.)
U U side 2 to 10 stations
OMRON Corp.: CompoBus/S System
R1 D D side 2 to 10 stations
(16 output points)
B Both sides 2 to 16 stations
OMRON Corp.: CompoBus/S System
R2 M Special specifications
(8 output points)
U JEMANET (JPCN-1) ∗ For special specifications, indicate
V Mitsubishi Electric Corp.: CC-LINK System separately on the manifold specification
sheet.
• For the general purpose type, a
transmission unit is require on the CPU
side. Valve stations
• Even though when it is not equipped with
Symbol Stations Note
SI unit, DIN rail length is long enough for
future expectancy of mounting SI unit. 02 2 stations Single wiring spec.
...

...

When a shorter rail is required (same as (Applicable up to 16


type 45), suffix “0” in the optional blank at
SI unit 16 16 stations solenoid valves.)
the end of part number. mounting position
∗ This also includes the number of
• For SI unit specifications, Refer to pages 1- Symbol Mounting position blanking plate assemblies.
4-171 to 1-4-173. U U side ∗ Two stations are necessary for the
D D side double, 3 position (Dual body type).

SI Unit Part No.


Symbol Specifications For SS5Y-45S1 Symbol Specifications: For SS5Y-45S1
A With general type SI unit (Series EX300) EX321-S001 J1 SUNX Corp.: S-LINK System (16 output points) EX121-SSL1
B Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System EX121-SMB1 J2 SUNX Corp.: S-LINK System (8 output points) EX121-SSL2
C OMRON Corp.: SYSBUS Wire System EX121-STA1 K Fuji Electric Co.: T-LINK Mini System EX121-SFU1
D SHARP Corp.: Satellite I/O Link System EX121-SSH1 Q Device Net: CompoBus/D (OMRON Corp.) EX121-SDN1
E Matsushita Electric Works: MEWNET-F System EX121-SPA1 R1 OMRON Corp.: CompoBus/S (16 output points) EX121-SCS1
F1 NKE Corp.: Uni-wire System (16 output points) EX121-SUW1 R2 OMRON Corp.: CompoBus/S (8 output points) EX121-SCS2
G Rockwell Automation: Allen Bradley Remote I/O (RIO) System EX121-SAB1 U JEMANET (JPCN-1) EX121-SJN1
H NKE Corp.: Uni-wire H System EX121-SUH1 V Mitsubishi Electric Corp.: CC-LINK System EX121-SMJ1
∗ For terminal LED descriptions and cable wiring, etc. for each SI unit, refer to pages 1-4-171 to 1-4-173.

For external pilot specifications and built-in silencer, refer to catalog on page 1-4-196.

1-4-176
Base Mounted

Series SY3000/5000

How to Order Valve Manifold Assembly How to Order Valves

Ordering example 2 position single SY 3 1 4 0 5 FU


Double solenoid (24 VDC)
SY3245-5FU
Single solenoid (24 VDC)
SY3140-5FU
Double, 3 position SY 3 2 4 5 5 FU
U side Series
3 SY3000
5 SY5000 SV
Type of actuation SZ
Sta
tio 2 2 position double
ns
....
.... 3 3 position closed center SY
.. 2 4 3 position exhaust center
1
5 3 position pressure center SYJ
Dual body type (Double, 3 position) SX
D side Rated voltage
Manifold base (5 stations) 5 24 VDC
SS5Y3-45S1AD-05U-C6

Manual override
S5Y3-45S1AD-05U-C6 1 set (Type 45S1 with serial unit 5 Nil Non-locking push type
station manifold base part no.)
∗ SY3140-5FU 3 sets (Single solenoid part no.)
D Push-turn locking slotted type
∗ SY3245-5FU 1 set (Double solenoid part no.) E Push-turn locking lever type

The asterisk denotes the symbol for assembly.


Prefix it to the part nos. of the solenoid valve, etc.
• The valve arrangement is numbered as the 1st. station from D side
regardless of the mounting position of SI unit.
• When ordering double solenoid valves/3 position (Dual body type), please
keep in mind that they require two manifold stations.

1-4-177
Base Mounted

Series SY3000/5000

SY5000: Serial Transmission Unit/Plug-in


C4, N3
SS5Y5-45S1U- Stations D- C6, N7
C8, N9
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
ø6, ø1/4" Note) The L1 to L4 dimensions of SS5Y5-45S1U-

14.5
P=16 17 26 C4, N3
ø8, ø5/16" Stations U- C6, N7 are identical to those of
C8, N9 C4, N3
SS5Y5-45S1U- Stations D- C6, N7 .
31.5

32
15.5

C8, N9
A A A A A R

B B B B B P
Button for DIN rail release One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
U side D side
9.3 30.8 L3 (L4)

(4.9)
M3 DIN rail holding screw

(3.5)
Terminal screw 8 DIN rail
6.2

41.2
PORT

PORT

B B
5.5
64

35
45
114.3

SOL.a

SOL.a
SOL.b

SOL.b

110.4
31.2
A A A

L2 5 Stations n 2 stations 3 4 5 6 7 8 9 10 stations


Manual override (Rail mounting hole pitch: 12.5) L1 173 185.5 210.5 223 235.5 260.5 273 285.5 298
L2 162.5 175 200 212.5 225 250 262.5 275 287.5
(Press and turn to operate
and lock override. ) L1
L3 105 121 137 153 169 185 201 217 233
A side: Orange (Station n) (Station 1) L4 13.5 12 16.5 14.5 13 17.5 15.5 14 12
B side: Green (Light/Surge voltage suppressor)
Note) Width of SI unit applicable to “E”:
Matsushita Electric Works, Ltd. and
“G”: Rockwell Automation, Inc.
71.1

widens to 24.3 mm . For further


66.1

information, please consult with


42.7
7.5

SMC.

Block separation button


C4, N3 (Push type)
SS5Y5-45S1U- Stations B-C6, N7 Button for DIN rail release
C8, N9 (Pitch)
15.5
14.5

47 P=16 17 26
31.5
32

R A A A A A R

P B B B B B P

One-touch fitting
(P, R port)
One-touch fitting Applicable tubing O.D.: ø10, ø3/8"
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side D side
9.3 30.8 L3 (L4) Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(4.9)

DIN rail holding screw L1 198 210.5 223 235.5 260.5 273 285.5 310.5 323
(3.5)

8 DIN rail L2 187.5 200 212.5 225 250 262.5 275 300 312.5
L3 123 139 155 171 187 203 219 235 251
L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5
41.2
PORT

PORT

B B
5.5

Stations n 11 stations 12 13 14 15 16 stations


64
45

L1 335.5 348 373 385.5 398 410.5


35
114.3

SOL.a

SOL.a
SOL.b

SOL.b

110.4
31.2

A A A
L2 325 337.5 362.5 375 387.5 400
L3 267 283 299 315 331 347
L4 14 12 16.5 15 13 11.5
Note) Width of SI unit applicable to “E”:
Matsushita Electric Works, Ltd. and
Manual override “G”: Rockwell Automation, Inc.
L2 5
(Press and turn to operate
and lock override. ) (Rail mounting hole pitch: 12.5)
widens to 24.3 mm . For further
information, please consult with
A side: Orange L1 SMC.
B side: Green

1-4-180
Base Mounted

Series SY3000/5000

SY5000: Serial Transmission Unit/Plug-in

C4, N3
SS5Y5-45S1D- Stations U-C6, N7 Button for DIN rail release
C8, N9 (Pitch)

15.5
P = 16 46
14.5
26 17 Note) The L1 to L4 dimensions of SS5Y5-45S1D-
C4, N3
Stations D- C6, N7 are identical to those of

31.5
C8, N9
C4, N3
32

R SS5Y5-45S1D- Stations U- C6, N7 .


A A A A A
C8, N9

P B B B B B

One-touch fitting One-touch fitting SV


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4" SZ
U side D side ø8, ø5/16"
L3 30.8 9.3 (L4) SY
DIN rail holding screw M3
(4.9)
(3.5)

DIN rail Terminal screw


SYJ

6.2
8
SX
41.2

PORT

PORT

B B

5.5

45
35

64
SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
31.2

A A A

Manual override
Press and turn to operate L2 5
( and lock override. ) (Rail mounting hole pitch: 12.5)
A side: Orange L1
B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor) Stations n 2 stations 3 4 5 6 7 8 9 10 stations
L1 173 185.5 210.5 223 235.5 260.5 273 285.5 298
L2 162.5 175 200 212.5 255 250 262.5 275 287.5
L3 105 121 137 153 169 185 201 217 233
71.1

66.1

L4 13.5 12 16.5 14.5 13 17.5 15.5 14 12


42.7
7.5

Note) Width of SI unit applicable to “E”:


Matsushita Electric Works, Ltd. and “G”:
Rockwell Automation, Inc. widens to
Block separation button 24.3 mm . For further information,
(Push type) please consult with SMC.
C4, N3
SS5Y5-45S1D- Stations B-C6, N7
C8, N9
26 17 47 Button for DIN rail release
15.5

(Pitch)
P = 16
31.5

32
14.5

R A A A A A R

P B B B B B P

One-touch fitting One-touch fitting


(P, R port) (A, B port)
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side D side
L3 30.8 9.3 (L4)
DIN rail holding screw
(4.9)
(3.5)

DIN rail Stations n 2 stations 3 4 5 6 7 8 9 10 stations


8 L1 198 210.5 223 235.5 260.5 273 285.5 310.5 323
L2 187.5 200 212.5 225 250 262.5 275 300 312.5
41.2

PORT

PORT

B B
L3 123 139 155 171 187 203 219 235 251
5.5

L4 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5


45
35

64
SOL.a

SOL.a
SOL.b

SOL.b
114.3
110.4
31.2

Stations n 11 stations 12 13 14 15 16 stations


A A A
L1 335.5 348 373 385.5 398 410.5
L2 325 337.5 362.5 375 387.5 400
L3 267 283 299 315 331 347
L4 14 12 16.5 15 13 11.5
Manual override Note) Width of SI unit applicable to “E”:
( Press and turn to operate
and lock override. ) L2
(Rail mounting hole pitch: 12.5)
5 Matsushita Electric Works, Ltd. and
“G”: Rockwell Automation, Inc. widens
A side: Orange
B side: Green L1 to 24.3 mm . For further information,
please consult with SMC.

1-4-181
3 Port Valve
Series SY300/500
Mixed Mounting Type on 5 Port Valve Manifold
3 port valve can be mounted on manifold for 5 port valve.

Application How to Order Valve Manifold Assembly

Possible to be mounted on all kinds of manifolds for Series Ordering example


SY3000/5000. 5 port valve: Double solenoid
Refer to “How to Order Manifold” for details. Cylinder port size
SY3220-5G-C6 (2 sets)
C6: With One-touch fitting for ø6
3 port valve: Single solenoid (N.C.)
5 port valve: Single solenoid SY313-5G-C6 (2 sets)
SY3120-5G-C6 (1 set)
Manifold base (5 stations)
–+
–+
SS5Y3-20-05
–+
EB
–+
–+ P
EA

SS5Y3-20-05 1 set (Type 20, 5 station manifold base part no.)


∗ SY313-5G-C6 2 sets (3 port valve, type NC part no.)
∗ SY3120-5G-C6 1 set (5 port valve, single solenoid part no.)
∗ SY3220-5G-C6 2 sets (5 port valve, double solenoid part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number. In
the case of complex arrangement, specify them on the manifold specification
sheet.

1-4-182
Series SY3000/5000

Body Ported/How to Order Valves

Individual Wiring: For SS5Y53 -20

SY 5 1 3 5 L 01
Thread type
Series Nil Rc
3 SY300 F G
5 SY500 N NPT
Type of actuation T NPTF SV
1 Normally closed (N.C.)
2 Normally open
A port size SZ
Thread piping
Solenoid type Symbol Port size Applicable series
M5 M5 x 0.8 SY300
SY
Nil Single solenoid
01 1 8 SY500
D Double solenoid
One-touch fitting (Metric size) One-touch fitting (Inch size) SYJ
Coil specifications Symbol Port size Applicable series Symbol Port size Applicable series
Nil Standard C4 One-touch fitting for ø4
SY300
N3 One-touch fitting for ø 5 32"
SY300
SX
T With power saving circuit (24 VDC, 12 VDC only) C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
C6 One-touch fitting for ø6 1
N7 One-touch fitting for ø 4 "
∗ Power saving circuit is not available in the SY500 SY500
case of “D”, “DO” or “W” type. C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"

Manual override
Rated voltage
DC AC Nil Non-locking push type
D Push-turn locking slotted type
5 24 VDC 1 100 VAC
E Push-turn locking lever type
6 12 VDC 2 200 VAC
V 6 VDC 3 110 VAC [115 VAC]
S 5 VDC 4 220 VAC [230 VAC] Light/Surge voltage suppressor
R 3 VDC Electrical entry for G, H, L, M, W Electrical entry for D
∗ DC specifications of type “D” and “DO” Nil Without light/surge voltage suppressor (SY500 only)
is only available with 12 and 24 VDC. S With surge voltage suppressor Nil Without light/surge voltage suppressor
∗ For type “W”, DC voltage is only Z With light/surge voltage suppressor S With surge voltage suppressor
available. R With surge voltage suppressor (Non-polar type) Z With light/surge voltage suppressor
U With light/surge voltage suppressor (Non-polar type) ∗ “DOZ” is not available.
∗ For AC voltage valves there is ∗ For AC voltage valves
Electrical entry no “S” option. It is already built- there is no “S” option. It
24, 12 VDC/ in to the rectifier circuit. is already built-in to the
24, 12, 6, 5, 3 VDC/ 24, 12, * For “R” and “U”, DC voltage is rectifier circuit.
100, 110,
100, 110, 200, 220 VAC 6, 5, 3 VDC only available.
200, 220 VAC
L plug M plug ∗ Power saving circuit is only
Grommet DIN terminal M8 connector available in the "Z" type.
connector connector
G: Lead wire L: With lead M: With lead D: With WO: Without
length wire (Length wire (Length connector connector
300 mm 300 mm) 300 mm) DO:Without cable
H: Lead wire LN: Without lead MN: Without lead connector
length wire wire
600 mm LO: Without MO: Without
connector connector
∗ “LN”, “MN” type: with 2 sockets. ∗ For connector cable of M8
∗ For DIN terminal of SY300 series, refer connector, refer to page 1-4-209.
to page 1-4-207.
∗ DIN terminal type “Y” conforming to DIN
43650C is also available. For details,
refer to page 1-4-201.

Note) When placing an order for body ported solenoid valve as a single
unit, mounting bolt for manifold and gasket are not attached. Order
them separately, if necessary.
(For details, refer to catalog on page 1-4-61.)

1-4-183
Series SY3000/5000

Body Ported/How to Order Valves


3
Flat ribbon cable: SS5Y 5 -20P
Light/Surge voltage suppressor A port size
Thread piping
Z With light/surge voltage suppressor
Symbol Port size Applicable series
With light/surge voltage suppressor M5 M5 x 0.8 SY300
U
(Non-polar type) 1 8
01 SY500
Note) Z: Positive common specifications only.
One-touch fitting (Metric size) One-touch fitting (Inch size)
Rated voltage Symbol Port size Applicable series Symbol Port size Applicable series
5 24 VDC C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
SY300 SY300
6 12 VDC C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
C6 One-touch fitting for ø6 1
N7 One-touch fitting for ø 4 "
SY500 SY500
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"

For DC: SY 5 1 3 5 LO Z
For AC: SY 5 1 3 1 LOZ Thread type
Nil Rc
Series
F G
3 SY300
N NPT
5 SY500
T NPTF
Type of actuation Manual override
Nil Non-locking push type
1 Normally closed (N.C.)
D Push-turn locking slotted type
2 Normally open (N.C.)
E Push-turn locking lever type
Solenoid type Rated voltage
Nil Single solenoid 1 100 VAC
D Double solenoid 3 110 VAC [115 VAC]

Base Mounted/How to Order Valves


3
Individual wiring: For SS5Y -41/42/45 5

SY 5 1 5 5 L
Series Manual override
3 SY300 Nil Non-locking push type
5 SY500 D Push-turn locking slotted type
Type of actuation E Push-turn locking lever type
1 Normally closed (N.C.)
2 Normally open (N.C.) Light/Surge voltage suppressor
Solenoid type Electrical entry for G, H, L, M, W Electrical entry for D (SY500 only)
Nil Single solenoid Nil Without light/surge voltage suppressor Nil Without light/surge voltage suppressor
D Double solenoid S With surge voltage suppressor S With surge voltage suppressor
Pilot type Z With light/surge voltage suppressor Z With light/surge voltage suppressor
Nil Internal pilot R With surge voltage suppressor (Non-polar type) ∗ DOZ is not available.
R External pilot U With light/surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no
∗ For AC voltage valves there is no “S” option. It “S” option. It is already built-in to
∗ External pilot is
is already built-in to the rectifier circuit. the rectifier circuit.
not available for
Type 41 manifold. ∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in
Coil specifications the "Z" type.
Nil Standard
T With power saving circuit (24 VDC, 12 VDC only)
∗ Power saving circuit is not available
Electrical entry
in the case of “D”, “DO” or “W” type. 24, 12 VDC/
24, 12, 6, 5, 3 VDC/ 24, 12,
100, 110,
Rated voltage 100, 110, 200, 220 VAC 6, 5, 3 VDC
200, 220 VAC
DC AC
L plug M plug
5 24 VDC 1 100 VAC Grommet DIN terminal M8 connector
connector connector
6 12 VDC 2 200 VAC G: Lead wire L: With lead wire M: With lead wire D: With connector WO: Without
V 6 VDC 3 110 VAC [115 VAC] length 300 mm (Length 300 mm) (Length 300 mm) DO: Without connector
S 5 VDC 4 220 VAC [230 VAC] H: Lead wire LN: Without lead wire MN: Without lead wire connector cable
R 3 VDC length 600 mm LO: Without connector MO: Without connector
∗ DC specifications of type “D” and “DO” is only ∗ “LN”, “MN” type: with 2 sockets. 43650C is also available. For details, refer to
available with 12 and 24 VDC. ∗ For DIN terminal of SY300 series, refer to page page 1-4-201.
∗ For type “W”, DC voltage is only available. 1-4-207. ∗ For connector cable of M8 connector, refer to
∗ DIN terminal type “Y” conforming to DIN page 1-4-209.

1-4-184
Series SY3000/5000

Base Mounted/How to Order Valves

Flat ribbon cable:


For SS5Y 35 -41P/42P/45-A
Connector box type:

Rated voltage Light/Surge voltage


5 24 VDC suppressor
6 12 VDC With light/surge voltage
Z suppressor
41P/42P With light/surge voltage SV
For DC: SY 5 1 5 5 LO Z U suppressor
45-A (Non-polar type)
SZ
Note) Z: Positive common
41P/42P For AC: SY 5 1 5 1 LOZ specifications only.
SY
Series Manual override
3 SY300
SYJ
Nil Non-locking push type
5 SY500 D Push-turn locking slotted type
E Push-turn locking lever type
SX
Type of actuation
1 Normally closed (N.C.) Rated voltage
2 Normally open (N.C.) 1 100 VAC
3 110 VAC [115 VAC]
Solenoid type Pilot type
Nil Single solenoid Nil Internal pilot
D Double solenoid R External pilot
∗ External pilot is not
available for Type 41P
manifold.

Plug-in: For SS5Y 53 -45

Single solenoid SY 5 1 5 5 FU
Double solenoid SY 5 1 5C 5 FU
Series Manual override
3 SY300 Nil Non-locking push type
5 SY500 D Push-turn locking slotted type
E Push-turn locking lever type
Type of actuation
1 Normally closed (N.C.) Rated voltage
2 Normally open (N.C.) For DC
5 24 VDC
6 12 VDC

Dual body type Pilot type


Nil Internal pilot
∗ When ordering double solenoid
R External pilot
valves (Dual body type), please
keep in mind that they require two
manifold stations.

1-4-185
Series SY3000/5000

Construction

JIS Symbol Normally closed (N.C.) JIS Symbol Normally closed (N.C.)
Single solenoid Double solenoid
Single solenoid Double solenoid

A A

w u w u
y e y

r EA P t q r EA P t q
JIS Symbol Normally open (N.O.) JIS Symbol Normally open (N.O.)
Single solenoid Double solenoid
Single solenoid Double solenoid

A A

w u w u
y e y

r EA P t q r EA P t q
Component Parts Replacement Parts
No. Description Material Note No. Description No.
Aluminum die-casted y Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 1-4-10.
q Body White
(SY3000: Zinc die-casted) u M5 port block assembly Refer to “How to Order Port Block Assembly” below.
w Adapter plate Resin White
e End plate Resin White
r Piston Resin —
t Spool valve assembly Aluminum, HNBR —

How to Order M5 Port Block Assembly


One-touch Mounting
SY 00 2A Thread type
fitting assembly screw

Series Nil Rc
3 Series SY300 F G
N NPT ∗ Only replacement of the fittings assembly is
5 Series SY500
T NPTF possible.
A, B port size
Thread piping One-touch fitting (Inch size) Metric size
Symbol Port size Applicable series
Symbol Port size Applicable series One-touch fitting for ø4 VVQ1000-50A-C4
SY300
M5 M5 x 0.8 SY300 N3 One-touch fitting for ø 5 32" One-touch fitting for ø6 VVQ1000-50A-C6
1 8
SY300 One-touch fitting for ø4 VVQ1000-51A-C4
01 SY500 N7 One-touch fitting for ø 1 4"
5 SY500 One-touch fitting for ø6 VVQ1000-51A-C6
One-touch fitting (Metric size) N3 One-touch fitting for ø 32"
N7 One-touch fitting for ø 1 4" SY500 One-touch fitting for ø8 VVQ1000-51A-C8
Symbol Port size Applicable series
C4 One-touch fitting for ø4 N9 One-touch fitting for ø 5 16" Port block assembly Inch size
SY300
C6 One-touch fitting for ø6 Caution (cassette type)
SY300
One-touch fitting for ø 5 32" VVQ1000-50A-N3
C4 One-touch fitting for ø4 One-touch fitting for ø 1 4" VVQ1000-50A-N7
Mounting screw tightening torques One-touch fitting for ø 5 32" VVQ1000-51A-N3
C6 One-touch fitting for ø6 SY500
C8 One-touch fitting for ø8 SY300 (M2) : 0.12 N·m SY500 One-touch fitting for ø 1 4" VVQ1000-51A-N7
SY500 (M3) : 0.6 N·m One-touch fitting for ø 5 16" VVQ1000-51A-N9

1-4-186
Series SY3000/5000

Specifications

Dimensions, specifications, solenoid specifications, response time and effective area are the same as 5 port valve.

Weight
SV
Series SY300 Series SY500
Type of Weight (g) Weight (g)
Valve model
actuation Grommet L, M plug connector
Valve model Type of
actuation Grommet L, M plug connector DIN terminal
SZ
Single 51 53 Single 69 72 93
SY33--M5
Double 68 74
SY53--01
Double 87 93 135 SY
Single 56 59 Single 82 82 103
SY33-- C4 SY53-- C4
N3 Double 74 79 N3 Double 100 102 144 SYJ
C6 Single 54 57 C6 Single 79 77 98
SY33-- N7 SY53-- N7
Double 72 77 Double 97 98 140 SX
Single 47 50 C8 Single 75 84 105
SY35- SY53-- N9
Double 65 70 Double 93 105 147
Single 55 58 79
SY55-
Double 73 78 120

1-4-187
Made to Order Specifications:
Series SX3000/5000 Serial Transmission Type
Type 45S2 With SMC’s IN313

Serial Transmission Manifold Equipped with SMC’s IN313


How to Order Manifold
Type 45S2 (Serial type with IN313)

SS5Y 3 45S2 U 06 D C4
Series
3 SY3000
5 SY5000 How to Order Applicable SI Unit
SI unit mounting position
Symbol Mounting position
U U side
IN313 MB1
D D side

Valve stations Applicable makers


Symbol Stations Note MB1 For Mitsubishi Electric Corporation
02 2 stations Single wining spec. TA1 For OMRON Corporation
FU1 For Fuji Electric Co., Ltd.
...

...

(Applicable up to
16 16 stations 16 solenoid valves.) SH1 For SHARP Corporation
TY1
∗ This also includes the number of For Toyoda Machine Works, Ltd.
blanking plate assemblies. TY2
∗ Two stations are necessary for the PA1 For Matsushita Electric Works Ltd.
double, 3 position (Dual body type). HT1 For Hitachi, Ltd.
AB1 For Rockwell Automation, Inc.
SUP/EXH block assembly mounting position TS1 For TOSHIBA Corporation
Symbol Mounting position Stations
U U side 2 to 10 stations
D D side 2 to 10 stations
B Both sides 2 to 16 stations How to Order Valves
M Special specifications
∗ For special specifications, indicate
separately on the manifold specification
sheet.
2 position single SY 3 1 4 0 5 FU
A, B port size
One-touch fitting (Metric size)
Symbol Port size Applicable series
Double, 3 position SY 3 2 4 5 5 FU
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6 SY3000
Series
M Mixed 3 SY3000
C4 One-touch fitting for ø4 5 SY5000
C6 One-touch fitting for ø6 Type of actuation
SY5000
C8 One-touch fitting for ø8 2 2 position double
M Mixed 3 3 position closed center
One-touch fitting (Inch size) 4 3 position exhaust center
Symbol Port size Applicable series 5 3 position pressure center
N3 One-touch fitting for ø 5 32"
N7 One-touch fitting for ø 1 4" SY3000 Dual body type (Double, 3 position)
M Mixed Rated voltage
N3 One-touch fitting for ø 5 32" 5 24 VDC
N7 One-touch fitting for ø 1 4"
SY5000
N9 One-touch fitting for ø 5 16"
M Mixed Manual override
∗ In the case of mixed specifications, indicate Nil Non-locking push type
separately on the manifold specification D Push-turn locking slotted type
sheet. E Push-turn locking lever type
Option
When a longer DIN rail is desired than the
specified stations, specify the station number to
be required. (20 stations at maximum)

For external pilot specifications and built-in silencer,


refer to page 1-4-196.
1-4-188
Series SY3000/5000

SY5000: Serial Transmission Unit/Plug-in


C4, N3
SS5Y3-45S2D- Stations U- C6, N7
C8, N9
(Pitch)

15.5
Button for DIN rail release
14.5 26 17 P = 16 46

31.5
32

R A A A A A Note) The L1 to L4 dimensions of SS5Y3-45S2D-


C4, N3 C4, N3
P B B B B B
Stations D- C6, N7 , SS5Y3-45S2U- Stations D- C6, N7 ,
C8, N9 C8, N9
One-touch fitting C4, N3
(P, R port) SS5Y3-45S2U- Stations U- C6, N7 are identical to
C8, N9
Applicable tubing O.D.: ø10, ø3/8" C4, N3
those of SS5Y3-45S2D- Stations U- C6, N7 .
C8, N9
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side L3 78 (L4) D side
(4.9)
(3.5)

54 12

8
POWER RUN SD RD
31.2 41.2

0 1 2 3 4 5 6 7 8 9 A B CDE F

18.2
PORT

PORT

B B B
5.5
35

OUTPUT
114.3

SOL.a

SOL.a
SOL.b

SOL.b
110.4

SMC IN313-MB1
ERROR

124
A A A

33.5
81.7
STATION NO.

DIN rail
x 10 x 1

12

DIN rail holding screw


G1/2
Manual override L2 5 29.3
(Signal, power supply output port)
Press and turn to operate
(
and lock override.
A side: Orange
) (Rail mounting hole pitch: 12.5)
L1
B side: Green
(Station n) (Station 1)
(Light/Surge voltage suppressor)
115.3

Stations n 2 stations 3 4 5 6 7 8 9 10 stations


72.9

L1 210.5 223 248 260.5 273 298 310.5 323 335.5


42.7
7.5

L2 200 212.5 237.5 250 262.5 287.5 300 312.5 325


27.3

L3 105 121 137 153 169 185 201 217 233


Block separation button 9 21 L4 13.5 12 16.5 14.5 13 17.5 15.5 14 12
(Push type) G1/2
(Signal, power supply output port)
C4, N3
SS5Y5-45S2U- Stations B-C6, N7
C8, N9 Note) The L1 to L4 dimensions of SS5Y5-45S2U-
(Pitch)
15.5

C4, N3
Button for DIN rail release 26 P = 16 17 47 Stations B- C6, N7 are identical to those of
C8, N9
C4, N3
SS5Y5-45S2D- Stations B- C6, N7.
14.5

31.5
32

C8, N9
R A A A A A R

P B B B B B P

One-touch fitting
(P, R port)
Applicable tubing O.D.: ø10, ø3/8"

One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side L3 78 (L4) D side
(4.9)
(3.5)

54 12

8
POWER RUN SD RD
32.5 41.2

0 1 2 3 4 5 6 7 8 9 A B CDE F

Stations n 2 stations 3 4 5 6 7 8 9 stations


PORT

PORT

B B B
35
5.5

OUTPUT

L1 235.5 248 260.5 273 298 310.5 323 348


114.3

SOL.a

SOL.a
SOL.b

SOL.b
110.4

SMC IN313-MB1

L2 225 237.5 250 262.5 287.5 300 312.5 337.5


124
ERROR

A A A

L3 123 139 155 171 187 203 219 235


81.7
STATION NO.

DIN rail
x 10 x 1

L4 17 15.5 13.5 12 16.5 14.5 13 17.5


12

Stations n 10 stations 11 12 13 14 15 16 stations


DIN rail holding screw L1 360.5 373 385.5 410.5 423 435.5 460.5
21
Manual override L2 5 L2 350 362.5 375 400 412.5 425 450
Press and turn to operate (Rail mounting hole pitch: 12.5) L3 251 267 283 299 315 331 347
( and lock override. ) L1 L4 15.5 14 12 16.5 15 13 17.5
A side: Orange
B side: Green

1-4-190
Made to Order Specifications:
Series SX3000/5000 Serial Transmission Type
Type 45S3 With OMRON Corp’s G71-OD16
Serial Transmission Manifold Equipped with OMRON Corp’s Transmission Unit G71-OD16
How to Order Manifold
SV
Type 45S3 (Serial type with transmission unit)
How to Order Valves SZ
SS5Y 3 45S3 U 06 D C4
Series
2 position single SY 3 1 4 0 5 FU SY
3 SY3000
SYJ
5 SY5000 Double, 3 position SY 3 2 4 5 5 FU
Specifications
Series
SX
Symbol Specifications
Nil With transmission unit 3 SY3000
0Note) Without transmission unit 5 SY5000
Note) Even though when it is not Type of actuation
equipped with transmission
unit, DIN rail length is long 2 2 position double
enough for future expectancy 3 3 position closed center
of mounting transmission 4 3 position exhaust center
unit. When a shorter rail is
5 3 position pressure center
required (same as type
45), suffix “0” in the Dual body type (Double, 3 position)
optional blank at the end of
part number. Rated voltage
5 24 VDC
Transmission unit mounting position
Manual override
Symbol Mounting position
U U side Nil Non-locking push type
D D side D Push-turn locking slotted type
E Push-turn locking lever type
Valve stations
Symbol Stations Note Internal Wiring of Manifold
02 2 stations Single wiring spec. Serial Type 45S3 (Example of arrangement)
...

...

(Applicable up to
16 16 stations 16 solenoid valves.)
∗ This also includes the number of Light/surge voltage
suppressor
Light/surge voltage
suppressor
blanking plate assemblies. Single solenoid Station 1 Station 9
∗ Two stations are necessary for the Light/surge voltage
suppressor
Light/surge voltage
suppressor
double, 3 position (Dual body type). Single solenoid
Light/surge voltage Station 2 Station 10 Light/surge voltage
suppressor suppressor
SUP/EXH block assembly mounting position Single solenoid
Light/surge voltage Station 3 Station 11 Light/surge voltage
Symbol Mounting position Stations suppressor suppressor
U U side 2 to 10 stations Station 4 Station 12
Double solenoid Light/surge voltage Light/surge voltage
D D side 2 to 10 stations Dual body type suppressor suppressor

B (Both sides) 2 to 16 stations Light/surge voltage Station 5 Station 13 Light/surge voltage


suppressor suppressor
M Special specifications
Double solenoid Station 6 Station 14
∗ For special specifications, indicate separately on the Light/surge voltage
suppressor
Light/surge voltage
suppressor
Dual body type
manifold specification sheet.
Light/surge voltage Station 7 Station 15 Light/surge voltage
suppressor suppressor
A, B port size
One-touch fitting (Metric size) One-touch fitting (Inch size) Station 8 Station 16
Symbol Port size Applicable series Symbol Port size Applicable series Minus port
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø 1 4" SY3000 Plus port (common)
M Mixed M Mixed Triangle mark
C4 One-touch fitting for ø4 N3 One-touch fitting for ø 5 32"
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16"
M Mixed M Mixed
Power supply terminal
∗ In the case of mixed specifications, indicate separately on the
manifold specification sheet.
Option • For specifications on OMRON Corp’s transmitter terminals, refer to the
When a longer DIN rail is desired than the specified instruction manual or the catalog of transmitter terminals, etc.
stations, specify the station number to be required. • Max. 16 solenoids are applicable. Please consult with SMC for more solenoids.
(20 stations at maximum)
For external pilot specifications and built-in silencer, Caution
refer to page 1-4-196. • The wiring specifications for SS5Y 35 -45S30 are different from those for SS5Y 35 -45PG.

1-4-191
Made to Order Specifications Series SY3000/5000

SY5000: Serial Transmission Unit/Plug-in


C4, N3
SS5Y5-45S3D- Stations U- C6, N7
C8, N9
(Pitch)

15.5
Button for DIN rail release 26 17 P = 16 46
Note) The L1 to L4 dimensions of SS5Y5-45S3D-

31.5
14.5
32

R A A A A A
C4, N3
Stations D- C6, N7 , SS5Y5-45S3U- Stations D-
C8, N9
P B B B B B
C4, N3 C4, N3
One-touch fitting C6, N7 , SS5Y5-45S3U- Stations U- C6, N7 are identical
C8, N9 C8, N9
(P, R port) C4, N3
Applicable tubing O.D.: ø10, ø3/8" to those of SS5Y5-45S3D- Stations U- C6, N7 .
C8, N9
SV
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" SZ
ø6, ø1/4"
ø8, ø5/16"
U side L3 60 12(L4) D side SY
(3.5)

(4.9)

DIN rail

4
SYJ
8

42.5
31.2 41.2

RUN OUTPUT

SX
B B B
PORT

PORT

5.5
35

85
114.3

SOL.a

SOL.a
SOL.b

SOL.b
110.4

ERR
T/R

POWER

A A A G71-OD16
OMRON RS485
- +
CH
OUT

24VDC
+COM
- + Transmission terminal Rail stopper
G71-OD16 TXE1-SMC
Manual override
DIN rail holding screw Power supply terminal
( Press and turn to operate
and lock override. )
A side: Orange
B side: Green
L2 5
(Rail mounting hole pitch: 12.5)
L1
Stations n 2 stations 3 4 5 6 7 8 9 10 stations
(Station n) (Station 1) L1 210.5 223 235.5 260.5 273 285.5 298 323 335.5
(Light/Surge voltage suppressor) 7.1 M3 L2 200 212.5 225 250 262.5 275 287.5 312.5 325
Terminal screw
L3 105 121 137 153 169 185 201 217 233
L4 16.5 15 13 17.5 16 14 12.5 17 15
72.9

68.1
42.7

7.5

Block separation button


Note) The L1 to L4 dimensions of SS5Y5-
(Push type)
C4, N3
45S3U- Stations B- C6, N7 are identical to
C4, N3 C8, N9
SS5Y5-45S3D- Stations B- C6, N7 those of SS5Y5-45S3D- Stations B-C6, N7.
C4, N3

C8, N9 C8, N9

(Pitch)
15.5

Button for DIN rail release 26 P = 16 17 47


31.5
14.5
32

R A A A A A R

One-touch fitting
P B B B B B P

(P, R port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting
(A, B port)
Applicable tubing O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
U side L3 60 12 (L4) D side
(4.9)
(3.5)

DIN rail
4

8
32.5 41.2

42.5

RUN OUTPUT
PORT

PORT

B B B
5.5

Stations n 2 stations 3 4 5 6 7 8 9 stations


35
85
114.3
110.4

SOL.a

SOL.a
SOL.b

SOL.b

L1 223 235.5 260.5 273 285.5 310.5 323 335.5


ERR
T/R

POWER

A A A G71-OD16
OMRON RS485
+-
L2 212.5 225 250 262.5 275 300 312.5 325
CH
OUT L3 123 139 155 171 187 203 219 235
24VDC
+COM
Rail stopper L4 14 12 16.5 15 13 17.5 16 14
- +
Transmission terminal
TXE1-SMC Stations n 10 stations 11 12 13 14 15 16 stations
Manual override G71-OD16
DIN rail holding screw L1 348 373 385.5 398 410.5 435.5 448
Press and turn to operate Power supply terminal
( and lock override. ) L2 337.5 362.5 375 387.5 400 425 437.5
A side: Orange
B side: Green
L3 251 267 283 299 315 331 347
L4 12.5 17 15 13.5 11.5 16 14.5
L2 5
(Rail mounting hole pitch: 12.5)
L1

1-4-193
Made to Order Specifications:
Series SY3000/5000
External Pilot/Built-in Silencer
Type 45 External pilot manifold bases for low-pressure/vacuum use are added to split style/DIN rail manifolds.
The built-in silencer has materialized a clear-cut appearance.

Individual Wiring/Connector Box Type


How to Order Manifold How to Order Valve Manifold Assembly
Type 45
Ordering example
3
SS5Y 45( A) 05 U R C65 Single solenoid (external pilot specifications)
Series SY3140R-5G (5 sets)
3 SY3000
5 SY5000
Built-in silencer
Valve Option
stations When a longer
Manifold base (5 stations)
SUP/EXH block assembly DIN rail is
Symbol Stations SS5Y3-45-05DRS-C6
mounting position desired than the

+

02 2 stations specified
+

Symbol Mounting position Stations +
...

...


+
stations, specify
U U side –
+

20 20 stations 2 to 10 stations the station


D D side
The number of number to be Us
blanking plate B Both sides 2 to 20 stations required. (Max. ide
assembly is M Special specifications 20 stations)
St
at
included.
io
∗ For special specifications,
ns

indicate separately on the 2 1


manifold specification sheet. Ds
ide
SUP/EXH block assembly specifications
Symbol Specifications
R External pilot SS5Y3-45-05DRS-C6 1 set (External pilot with built-in
S Internal pilot/Built-in silencer silencer part no.)
∗ SY3140R-5G 5 sets (Single solenoid part no.)
RS External pilot/Built-in silencer
The asterisk denotes the symbol for assembly.
A, B port size Prefix it to the part nos. of the solenoid valve, etc.
One-touch fitting (Metric size) One-touch fitting (Inch size) The valve arrangement is numbered as the 1st. station from D side regardless of
the mounting position of SUP/EXH block assembly. In ordering, specify the part nos.
Symbol Port size Applicable series Symbol Port size Applicable series in the order from the 1st. station on D side. Besides, when the arrangement will be
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" complicated, fill out the manifold specification sheet to instruct us.
For manifolds with SUP/EXH block assembly at each end of the manifold, external
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1 4" SY3000
pilot ports and silencers will be also located at each end of the manifold.
M Mixed M Mixed The SUP/EXH block assembly (SX3/5000-51-1A), for special usage, as shown on
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" page 1-4-130, can also be mounted. Please specify the mounting position, by
correctly filling in the blank space on the manifold specification sheet.
C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4"
SY5000 SY5000
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
M Mixed M Mixed
∗ In the case of mixed specifications, indicate separately on the manifold
specification sheet.

1-4-194
Made to Order Specifications Series SY3000/5000

How to Order Valves

SY 5 2 40 5 L
Series Manual override
3 SY3000 Nil Non-locking push type
5 SY5000 D Push-turn locking slotted type
E Push-turn locking lever type
Type of actuation SV
Light/Surge voltage suppressor
1 2 position single
2 2 position double Electrical entry for G, H, L, M, W
3 3 position closed center Nil Without light/surge voltage suppressor SZ
4 3 position exhaust center S With surge voltage suppressor
5 3 position pressure center Z With light/surge voltage suppressor SY
R With surge voltage suppressor (Non-polar type)

Pilot type
U With light/surge voltage suppressor (Non-polar type) SYJ
∗ For AC voltage valves there is no “S” option. It is
Nil Internal pilot already built-in to the rectifier circuit.
R External pilot ∗ For “R” and “U”, DC voltage is only available.
SX
∗ Power saving circuit is only available in the "Z" type.
Coil specifications Electrical entry for D (SY5000 only)
Nil Standard Nil Without light/surge voltage suppressor
T With power saving circuit (24 VDC, 12 VDC only) S With surge voltage suppressor (Non-polar type)
∗ Power saving circuit is not Z With light/surge voltage suppressor (Non-polar type)
available in the case of “D”, “DO” ∗ “DOZ” is not available.
or “W” type. ∗ For AC voltage valves there is no “S” option. It is
Rated voltage already built-in to the rectifier circuit.
DC
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
AC ( 50 60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of type “D”
and “DO” is only available
with 12 and 24 VDC.
∗ For type “W”, DC
voltage is only available.
∗ “D” and “DO” only
available for SY5000.

Electrical entry
24, 12 VDC/
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 100, 110, 24, 12, 6, 5, 3 VDC
200, 220 VAC
Grommet L plug connector M plug connector DIN terminal M8 connector
G: Lead wire length L: With lead wire M: With lead wire (SY5000 only) WO: Without connector
300 mm (Length 300 mm) (Length 300 mm) D: With connector cable
H: Lead wire length LN: Without lead wire MN: Without lead wire DO: Without connector
600 mm LO: Without connector MO: Without connector
∗ “LN”, “MN” type: with 2 sockets.
∗ “D” and “DO” only available for SY5000.
∗ DIN terminal type “Y” conforming to DIN43650C standard is also available. For details, refer to page 1-4-201.
∗ Setting “-5LOU” is available only for connector box type.
∗ For connector cable of M8 connector, refer to pages 1-4-209 to 210.

1-4-195
Series SY3000/5000

Plug-in

How to Order Manifold How to Order Valve Manifold Assembly


Type 45쏔
3 Ordering example
SS5Y 5 45 F U 05 U R Single solenoid (external pilot specifications)
SY3140R-5FU (3 sets)
Series Double solenoid (external pilot specifications)
3 SY3000 SY3245R-5FU (1 set)
5 SY5000
Common specifications Connector Built-in silencer
Nil Positive common mounting position
N Negative common Symbol Mounting position Manifold base (5 stations)
No symbol is used for T, T1, S쏔 types. U U side SS5Y3-45FU-05DRS-C6
D D side
Connector type
Symbol Mounting position
F D-sub connector U si
de S
P Flat ribbon cable 26 pins tatio
ns
PG Flat ribbon cable 20 pins
PH Flat ribbon cable 10 pins 2 1
D si
T Terminal block 9 pins de
T1 Terminal block 18 pins
SS5Y3-45FU-05DRS-C6 1 set (External pilot with built-in
S Serial transmission type silencer part no.)
∗ For details, refer to ∗ SY3140R-5FU 3 sets (Single solenoid part no.)
page 1-4-140. ∗ SY3245R-5FU 1 set (Double solenoid part no.)
Valve stations The asterisk denotes the symbol for assembly.
Symbol Stations Note Prefix it to the part nos. of the solenoid valve, etc.
02 2 stations The valve arrangement is numbered as the 1st. station from D side regardless of the
Single wining mounting position of SUP/EXH block assembly. In ordering, specify the part nos. in
...

...

specificatios the order from the 1st. station on D side. Besides, when the arrangement will be
20 20 stations complicated, fill out the manifold specification sheet to instruct us.
For manifolds with SUP/EXH block at each end of the manifold, external pilot ports
∗ This also includes the number of blanking plate assemblies. and silencers will be also located at each end of the manifold.
∗ Depending on the connector, the number of stations is The SUP/EXH block assembly (SX3/5000-51-1A), for special usage, as shown on
limited. Refer to page 1-4-143. page 1-4-130, can also be mounted. Please specify the mounting position, by
∗ Two stations are necessary for the double, 3 position (Dual correctly filling in the blank space on the manifold specification sheet.
Two stations of the manifold base are necessary for the double, 3 position (Dual
body type).
body type). Use caution when specifying the number of stations required for the
SUP/EXH block assembly mounting position manifold base.

Symbol Mounting position Stations


U U side
2 to 10 stations
How to Order Valves
D D side
B (Both sides) 2 to 20 stations
M Special specifications SY 3 1 4 5 FU
∗ For special specifications, indicate separately
on the manifold specification sheet. Series
SUP/EXH block assembly specifications 3 SY3000
Symbol Specifications 5 SY5000
R External pilot
S Internal pilot/Built-in silencer Type of actuation
RS External pilot/Built-in silencer 1 2 position single
2 2 position double
A, B port size 3 3 position closed center
One-touch fitting (Metric size) One-touch fitting (Inch size)
4 3 position exhaust center
Symbol Port size Applicable series Symbol Port size Applicable series 5 3 position pressure center
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32"
C6 One-touch fitting for ø6 SY3000 N7 One-touch fitting for ø1 4" SY3000 Body Option
M Mixed M Mixed 0 Standard (Single only)
C4 One-touch fitting for ø4 N3 One-touch fitting for ø5 32" 5 Dual body type (Double, 3 position)
C6 One-touch fitting for ø6 N7 One-touch fitting for ø1 4"
SY5000 SY5000 Pilot type
C8 One-touch fitting for ø8 N9 One-touch fitting for ø5 16"
Nil Internal pilot
M Mixed M Mixed
R External pilot
∗ In the case of mixed specifications, indicate separately on the manifold
specification sheet. Rated voltage
Voltage
5 24 VDC
Nil 24 VDC Option Manual override
6 12 VDC
12V 12 VDC When a longer DIN rail is desired than
V∗ 6 VDC Nil Non-locking push type
No symbol is used for T, T1, S쏔 types. the specified stations, specify the
station number to be required. S∗ 5 VDC D Push-turn locking slotted type
(20 stations at maximum) R∗ 3 VDC E Push-turn locking lever type
∗ Mark: 45T and T1 only
S쏔 type is available
for 24 VDC only.

1-4-196
Made to Order Specifications Series SY3000/5000

External Pilot/Built-in Silencer [ ]: AC

SY3000: SS5Y3-45- Stations DRS-C4, N3


C6, N7
U side D side
One-touch fitting
(P port)
One-touch fitting
Applicable tubing O.D.: ø8, ø5/16"
SS5Y3-45- Stations DR-C4, N3
C6, N7
(A, B port) (Pitch)

10.2
Applicable tubing O.D.: ø4, ø5/32" P = 10.5 13.5 24.8 Button for DIN rail release 1.2
ø6, ø1/4"
11.2
22.2

SV

25.2
A A A A A A A
63.3 [70.3]

38.6
48.4

50
63.7
B B B B B B
P P

- + - +
PE
One-touch fitting
SZ
(P, R port)
X X

(Light/Surge voltage suppressor) 1.2 One-touch fitting One-touch fitting


Applicable tubing O.D.: ø8, ø5/16" SY
(X port) (PE, X port)
(Station 1) Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32" SYJ
(Lead wire length)

(Station n)
97.3 [101.7] Approx. 300

Manual override
(C6: 3.2)
(N7: 7)

Silencer SX
(Air discharge port)
(3)

88.8 [93.2]
39.9 [42.1] 37.2

8
28.7

34
15.7

B B B B B B B
5.5
35

A A A A A A
33

DIN rail (L4)


L3
DIN rail holding screw L2 5
(Rail mounting hole pitch: 12.5)
L1
∗ The dimensions L1 to L4 are identical to those of
U C4, N3
SS5Y3-45- Stations D -C6, N7 .
B

C4, N3
SY5000: SS5Y5-45- Stations DRS-C6, N7
C8, N9 C4, N3
U side D side SS5Y5-45- Stations DR- C6, N7
One-touch fitting
C8, N9
(A, B port)
Applicable tubing O.D.: ø4, ø5/32" (Pitch)
ø6, ø1/4" P = 16 17 26 Button for DIN rail release 6.8
ø8, ø5/16"
15.5
31.5
71.1 [78.1]

32

46.5
14.5
54.5
55.7

A A A A A A R
72.4

B B B B B P B P

PE
-+ -+
X X One-touch fitting
(P, R port)
(Light/Surge voltage suppressor) 3.4 One-touch fitting
Applicable tubing O.D.: ø10, ø3/8"
(Station n) (Station 1) (P port)
Applicable tubing O.D.: ø10, ø3/8"
One-touch fitting One-touch fitting
(X port) (PE, X port)
Applicable tubing O.D.: ø4, ø5/32" Applicable tubing O.D.: ø4, ø5/32"
(Lead wire length)
119.9 [124.3] Approx. 300

Manual Silencer (Air discharge port)


override
DIN rail holding screw
(4.9)

(3.5)

DIN rail
107.2 [111.6]
53.4 [55.6] 44.2

41.2

8
31.6

B B B B B B
35
5.5

31.2
48.3

A A A A A A

L3 (L4)
L2 5
(Rail mounting hole pitch: 12.5)
∗ The dimensions L1 to L4 are identical to those of
L1 U C4, N3
SS5Y3-45- Stations D - C6, N7.
B C8, N9
3
∗ The dimensions of SS5Y 5 -45- Stations URS are identical to
those of SS5Y 35-45F- Stations DRS.

1-4-197
Series SY3000/5000

External Pilot/Built-in Silencer

SY3000: SS5Y3-45FU- Stations DRS- C4, N3


C6, N7
One-touch fitting SS5Y3-45FU- Stations DR- C4, N3
C6, N7
(A, B port) (Pitch) Button for DIN rail release
Applicable tubing O.D.: ø4, ø5/32"

10.2
P = 10.5 13.5 24.8 1.2
ø6, ø1/4"
22.2
11.2

25.2
A A A A A A A

38.6
R

50
63.3

63.7
B B B B B B
P P

PE

X X
One-touch fitting
(P, R port)
1.2 One-touch fitting Applicable tubing O.D.: ø8, ø5/16"
(Station n) (Station 1) (P port)
Applicable tubing O.D.: ø8, ø5/16" One-touch fitting
(PE, X port)
One-touch fitting Applicable tubing O.D.: ø4, ø5/32"
(X port)
Applicable tubing O.D.: ø4, ø5/32"

U side Silencer D side


(Air discharge port)
L3 L4
(C6: 3.2)

Equivalent to the applicable 26.5 DIN rail holding screw


(N7: 7)

D-sub connector {JIS-X-5101, MIL-C-24308}


(3)

M2.6 DIN rail


8
34
PORT

PORT

B B B B B
SOL.a

SOL.a
SOL.b

SOL.b
5.5
35

A
15.7
87.7
92

A A A
3.9

24VDC
+COM
Manual override
- +
Press and turn to operate
( and lock override. )
Terminal no. 1 A side: Orange
Power supply terminals L2 5 B side: Green
The voltage indication (Rail mounting hole pitch: 12.5)
(
marking is for 24 VDC. ) L1
∗ The dimensions L1 to L4 are identical to those of
C4, N3 U C4, N3
SY5000: SS5Y5-45FU- Stations DRS- C6, N7 SS5Y3-45F U
D- Stations D - C6, N7 .
B
One-touch fitting C8, N9
C4, N3
(A, B port) SS5Y5-45FU- Stations DR- C6, N7
Applicable tubing O.D.: ø4, ø5/32" (Pitch) C8, N9
ø6, ø1/4" P = 16 17 26 Button for DIN rail release 6.8
ø8, ø5/16"
15.5
31.5

32

46.5
14.5
54.5

A A A A A A R
72.4
72.9

B B B B B P B P

PE

X X One-touch fitting
(P, R port)
3.4 One-touch fitting Applicable tubing O.D.: ø10, ø3/8"
(P port) One-touch fitting
(Station n) (Station 1) Applicable tubing O.D.: ø10, ø3/8" (PE, X port)
One-touch fitting Applicable tubing O.D.: ø4, ø5/32"
(X port)
Applicable tubing O.D.: ø4, ø5/32"
U side Equivalent to the applicable D side
D-sub connector {JIS-X-5101, MIL-C-24308}
L3 L4
(4.9)
(3.5)

27 M2.6
DIN rail holding screw
8 DIN rail
41.2

PORT

PORT

B B
5.5
35

SOL.a

SOL.a
SOL.b

SOL.b
114.3

19.4
110.4

32.5

A A A A

Silencer
24VDC
+COM (Air discharge port)
- +

Manual override
Terminal no. 1 Press and turn to operate
Power supply terminals
L2 5 ( and lock override. ) ∗ The dimensions L1 to L4 are identical to those of
(Rail mounting hole pitch: 12.5) A side: Orange U C4, N3
The voltage indication U
(marking is for 24 VDC. ) L1 B side: Green SS5Y3-45FD - Stations D
B
- C6, N7.
C8, N9

∗ The dimensions of SS5Y 35 -45- Stations URS are identical to


3
those of SS5Y 5-45- Stations DRS.

1-4-198
Made to Order Specifications:
Series SY3000/5000
Type M45 Mixed Mounting
Non plug-in
Use SY3000 together with SY5000, which has a large Cv and is mounted only in a place where it is needed, permits a selection of economic manifold bases.
How to Order Manifold How to Order Valve Manifold Assembly
Type M45 (Mixed mounting type)
SV
Ordering example
SS5Y5 M45 05 U C86 Manifold base (5 stations)
SS5Y5-M45-05U-C86
Mixed mounting SZ
Single solenoid valve
type SY3140-5G (3 sets)
Valve stations Single solenoid valve SY
SY3140-5G (2 sets)
Symbol Stations SUP/EXH block assembly mounting position Option
02 2 stations
Symbol Mounting position Stations When a longer
SYJ
...

...

U U side DIN rail is desired


2 to 10 stations
20 20 stations D D side than the specified SX
The number B Both sides 2 to 20 stations stations, specify
of blanking M Special specifications the station
plate ass’y is ∗ For special specifications, indicate separately number to be
included, too. on the manifold specification sheet. required.
(Max. 20 stations) U si
de S
SUP/EXH block assembly specifications tatio
ns
Symbol Specifications
Nil Standard/Internal pilot
S Built-in silencer Manifold block
assembly for 2 1
∗ External pilot is unavailable for mixed mounting D si
SY5000 de
style. A, B port size SX5000-50-1A Manifold block assembly for SY3000
One-touch fitting (Metric size) One-touch fitting (Inch size) SX5000-50-8A
Symbol Port size Symbol Port size
One-touch fitting for ø5 32" SS5Y5-M45-05U-C86 1 set (Type M45, manifold base part no.)
C44 SY5000: One-touch fitting for ø4
SY3000: One-touch fitting for ø4
N33 SY5000:
SY3000: One-touch fitting for ø5 32" ∗ SY3140-5G 3 sets (Single solenoid part no.)
C46 SY5000: One-touch fitting for ø4 N37 SY5000: One-touch fitting for ø5 32" ∗ SY5140-5G 2 sets (Single solenoid part no.)
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4"
The asterisk denotes the symbol for assembly.
C64 SY5000: One-touch fitting for ø6 N73 SY5000: One-touch fitting for ø1 4"
SY3000: One-touch fitting for ø4 SY3000: One-touch fitting for ø5 32" Prefix it to the part nos. of the solenoid valve, etc.

C66 SY5000: One-touch fitting for ø6 N77 SY5000: One-touch fitting for ø1 4" The valve arrangement is numbered as the 1st. station from D side regardless of
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4" the mounting position of SUP/EXH block assembly. In ordering, specify the part nos.
One-touch fitting for ø5 16" in the order from the 1st. station on D side. Besides, when the arrangement will be
C84 SY5000: One-touch fitting for ø8
SY3000: One-touch fitting for ø4
N93 SY5000:
SY3000: One-touch fitting for ø5 32" complicated, fill out the manifold specification sheet to instruct us.

C86 SY5000: One-touch fitting for ø8 N97 SY5000: One-touch fitting for ø5 16"
SY3000: One-touch fitting for ø6 SY3000: One-touch fitting for ø1 4"
M Mixed M Mixed
∗ In the case of mixed specifications, indicate separately on the manifold
specification sheet.

How to Order Valves

SY 5 2 40 5 L
Manual override
Electrical entry for G, H, L, M, W Nil Non-locking push type
Series Nil Without light/surge voltage suppressor D Push-turn locking slotted type
3 SY3000 S With surge voltage suppressor E Push-turn locking lever type
5 SY5000 Z With light/surge voltage suppressor
Coil specifications R With surge voltage suppressor (Non-polar type)
Type of actuation Nil Standard U With light/surge voltage suppressor (Non-polar type)
1 2 position single With power saving circuit ∗ For AC voltage valves there is no “S” option.
2 2 position double T (24 VDC, 12 VDC only) It is already built-in to the rectifier circuit.
3 3 position closed center ∗ Power saving circuit ∗ For “R” and “U”, DC voltage is only available.
4 3 position exhaust center is not available in ∗ Power saving circuit is only available in the "Z" type.
5 3 position pressure center the case of “D”,
“DO” or “W” type. Electrical entry
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC
Rated voltage Grommet L plug connector M plug connector M8 connector
DC
G: Lead wire L: With lead wire M: With lead wire WO: Without
5 24 VDC AC ( 50 60 Hz)
length 300 mm (Length 300 mm) (Length 300 mm) connector
6 12 VDC 1 100 VAC H: Lead wire LN: Without lead wire MN: Without lead wire cable
V 6 VDC 2 200 VAC length 600 mm LO: Without connector MO: Without connector
S 5 VDC 3 110 VAC [115 VAC] ∗ “LN”, “MN” type: with 2 sockets.
R 3 VDC 4 220 VAC [230 VAC] ∗ For connector cable of M8 connector, refer to page 1-4-209.

∗ For type “W”, DC voltage is only available.

1-4-199
Series SY3000/5000

Dimensions: Mixed Mounting [ ]: AC

SS5Y5-M45- Stations U SY5000 SY3000


Pitch Pitch

16.9
15.5
Button for DIN rail release 26 17 P=16 P=12.5 23.3
L dimension: Formulae for L1, L4
14.5

31.5
L3 = 12.5 x n1 + 16 x n2 + 52
71.1 [78.1]

71.5 [78.5]
32

R A A A A A A
L3
M= ( + 1) Omit decimals
P B B B B B B
One-touch fitting 12.5
One-touch fitting
+

A, B port L1 = 12.5 x M + 23
P, R port -+ -+ -+ -+
Applicable tubing O.D.: ø4, ø5/32"
Applicable tubing O.D.: ø10, ø3/8" ø6, ø1/4" L2 = L1–10.5
One-touch fitting
L4= (L1–L3) /2
(Light/Surge voltage suppressor)
A, B port n1 = Number of SY3000
Applicable tubing O.D.: ø4, ø5/32" (Station n) (Station 1) n2 = Number of SY5000
ø6, ø1/4"
(Lead wire length)
Approx. 300

ø8, ø5/16" L3

(Lead wire length)


17 18 16 x n2 12.5 x n1 17

Approx. 300
Note) The L1 to L4 dimensions of
16 12.5 SS5Y5-M45- Stations D are
(SY5000) (SY3000) identical to those of SS5Y5-M45-
(C6: 3.2)
(N7: 7)
Stations U.
(3.5)
-6

DIN rail
44.2
120 [124.4]

41.2

8
107.4 [111.8]

97.5 [101.9]
31.2 31.6

46.3 [48.5] 28.9


B B B
24 20.4

89 [93.4]
35

B B B
5.5
53.5 [55.7]

A A A
48.3

A A A

DIN rail holding screw


Manual override
(L4)
L2 5
(Rail mounting hole pitch: 12.5)
L1

SS5Y5-M45- Stations B
SY5000 SY3000
Pitch Pitch L dimension: Formulae for L1, L4
15.5

16.9

Button for DIN rail release 26 17 P=16 P=12.5 15.3 26 L3 = 12.5 x n1 + 16 x n2 + 70


L3
M= ( + 1) Omit decimals
31.5

12.5
32
71.1 [78.1]

71.5 [78.5]
14.5

L1 = 12.5 x M + 23
R A A A A A A R

P B B B B B B P L2 = L1 – 10.5
One-touch fitting One-touch fitting L4 = (L1 – L3)/2
P, R port -+ -+ -+ -+ A, B port
Applicable tubing O.D.: ø10, ø3/8" Applicable tubing O.D.: ø4, ø5/32" n1 = Number of SY3000
One-touch fitting
ø6, ø1/4" n2 = Number of SY5000
(Light/Surge voltage suppressor)
A, B port
Applicable tubing O.D.: ø4, ø5/32" (Station n) (Station 1)
ø6, ø1/4"
(Lead wire length)

ø8, ø5/16"
Approx. 300

L3
(Lead wire length)
Approx. 300

17 18 16 x n2 12.5 x n1 18 17
16 12.5
(SY5000) (SY3000)
(C6: 3.2)
(N7: 7)
(3.5)
-6

DIN rail
44.2
120 [124.4]

41.2

8
107.4 [111.8]

97.5 [101.9]
31.2 31.6

46.3 [48.5] 28.9

B B B
24 20.4

89 [93.4]

B B B
35
5.5
53.5 [55.7]

A A A
48.3

A A A

Manual
DIN rail holding screw
override (L4)
L2 5
(Rail mounting hole pitch: 12.5)
L1

1-4-200

Das könnte Ihnen auch gefallen