LED lights the world 2
LED basics 10
1
LED lights the world
The lighting industry is undergoing a radical transformation that has opened up exciting and ground-breaking possibilities, and
it is all thanks to LED.
LED technology has come a long way since being introduced decades ago as mere light indicators of gadgets. Today, LED
lighting has been rapidly gaining traction as a sustainable, highly-efficient way to light up buildings and arenas. It is also a more
innovative solution to provide increased security and functionality among communities and businesses around the globe.
With the growing use of LED lighting solutions, businesses are presented with unique opportunities to harness the many
advantages of this evolving, environmentally-friendly light source for even more applications.
Meaningful innovations have made LED lighting more relevant than ever before, and in many cases surpassing the
performance of conventional lighting sources. So, leaf through this guide as we explain in detail what LED lighting is all about
and debunk some of its common misconceptions.
2 3
Benefits of LED technology
Energy efficiency
LED lighting is up to 5 times more efficient than incandescent and most halogen sources, providing significant energy
savings. LED lighting is also rapidly gaining ground on fluorescent light. As more and more legislations, and new
regulatory requirements limit energy use in new constructions and renovations, the use of LED lighting fixtures enables
infrastructures to comply efficiently with today’s standards and regulations.
Environmentally safe
LED lighting sources are mercury-free and are therefore safe for the environment. Unlike standard fluorescent
and compact fluorescent sources that contain mercury, LED lighting systems do not require special handling for
disposal and/or recycling, and do not contribute to hazardous waste.
Long lifetime
LED lighting sources have significantly longer lifetimes than traditional lighting technologies. This means less
replacement and maintenance requirements, resulting in significant cost savings.
Durability
LED lighting sources can withstand impact, vibration, and other disruptions. This robust quality makes LED lighting
systems a better fit for extreme environments, areas susceptible to high vibration, and other environments where the
installation and maintenance of traditional light sources may be more difficult.
Benefits of
LED technology
The long list of advantages associated with LED lighting systems has led to the significant
and sustained increase in their usage around the world. Below are the key factors that have
heightened the use of LED in both indoor and outdoor applications.
4 5
LED fast facts
LED
An LED (light-emitting diode) is a semi-conductor device or chip that produces light when an electrical current is
applied.
Remember:
LEDs are just one of many components – optics, housing, power sources, to name a few – used to create an
LED fixture or lamp. When looking at claims about lifetime, efficiency, and design, it is important to compare the
specifications of the entire LED system as a whole, not just the specifications of the individual system components.
Remember:
It is important to note that the efficacy of the LEDs themselves is always greater than the efficacy of the LED fixture. This
is caused by many factors including losses as light bounces off reflectors and passes through lenses. Make sure when
specifying a light fixture that you are looking at the appropriate fixture data versus the LED source data.
Lifetime
For traditional lighting sources, lifetime is reported as “mean time to failure,” which means the average time it takes for some
percentage of lamps (usually 50%) to fail completely. With an LED source, light output diminishes gradually. So for LED sources,
lifetime translates to how long a lighting fixture retains a certain percentage of its initial light output, which is also called lumen
maintenance.
Remember:
The lifetimes of LED sources and traditional light sources are defined differently. For white LEDs, lifetime is referred to as the time
after which 70% of the original light output remains, not when the source has completely burnt out.
Directionality
LED fast facts LEDs are directional sources. Traditional light sources (e.g., the incandescent bulb) emit light in all directions. In order to collect
light and direct it onto the surface you are trying to illuminate, you must use lenses and reflectors, which absorb light and
reduce the total output of the fixture.
6 7
LED fast facts
Remember:
Certain light sources are associated with particular color temperatures. LED fixtures come in a variety of fixed color
temperatures, making them easy to replace or combine with current light sources. Some LED fixtures also provide a
range of color temperatures within a single fixture.
Remember:
The higher the CRI, the better the fixture’s ability to show true colors.
Sustainability
LED lighting is often linked to sustainability in the context of energy. But sustainability is a much larger concept,
with energy efficiency being just one component. Sustainability takes into account environmental responsibility,
including waste reduction, recyclability, materials and resources, and building and design practices themselves.
Remember:
LED lighting supports sustainable design in several ways: it can reduce energy consumption, it requires
infrequent replacement (leading to less waste), and it contains no hazardous mercury. Some LED fixtures are
designed to be disassembled more easily for recycling.
8 9
LED basics
Does the quoted lifetime include the electronics and other components necessary to
drive the LED source?
Under the right conditions, LEDs can operate for very long periods of time. However, it is important that the supporting
components used in the fixture design also have long lifetimes and are of high quality.
What is the maximum ambient temperature under which the fixture can operate and
achieve rated life?
The lifetime numbers for many fixtures are quoted at room temperature. Make sure to ask what the fixture lifetime will be at the
extreme end of the quoted operating temperature range.
Does the fixture design have any special features for heat sinking/thermal
management?
Thermal management plays an integral part in the length of LED source lifetime and is directly affected by fixture design. Heat
must be properly drawn away from the LED source in order to maximize product lifetime– this can be achieved through an
appropriately designed heat sink.
If multiple white light fixtures are used on a project, are color points among them
adequately matched?
The tint or hue of white LEDs vary from batch to batch due to inherent variations that occur in all semiconductor
fabrication processes. Make sure to ask how the manufacturer ensures consistent color performance from fixture to
fixture.
Does the proposal for my job include all of the necessary components to operate the
LED fixtures?
Many LED fixtures require external transformers and other necessary controls in order to complete installation. Be sure
to include all of these components in your project budget.
LED basics
Equipped with the right questions to ask before placing any purchase, you will get a better
understanding of how LED lighting can best meet your requirements.
The following list of Q&A’s serves as a purchasing guide to help you get the best quality and most
appropriate fixture for your application.
10 11
Common LED myths
MYTH
Myth 1 LEDs last forever
LEDs have a long source life, but like all light sources, they slowly fade over time. This light output
FACT
degradation, also known as lumen maintenance (or lumen depreciation), is predicted by testing
LEDs over a long period of time in order to determine when a specified percentage of light output is
lost. Ambient temperatures, electrical drive currents, and the effectiveness of cooling systems are all
factors that contribute to lumen depreciation. While LEDs typically do not catastrophically fail, lumen
maintenance is a critical factor in determining useful lifetimes.
FACT
Myth 2 LEDs are not bright enough
LED traffic lights are already common and are certainly a sign that LEDs are bright enough to be seen
even in daylight. Outdoor roads, tunnels, entire building façades and indoor offices, and shop floors are
Notwithstanding the numerous benefits linked to LED lighting, misconceptions and
being lit entirely with LEDs today. By any measure, illuminance or luminance, LEDs have enough light
inaccuracies on its nature and advantages still abound. The following list dispels the myths
output for use even in very large outdoor daylight-visible installations.
surrounding LED lighting and provides a clearer explanation about how the technology really
works and how it can work for you.
MYTH
Myth 3 White LEDs produce over 180 lumens per watt
Many manufacturers test their LED chips on lab benches at room temperature conditions with short “pulse” tests that
FACT
produce a high lumen output that is not directly comparable with practical use. While these results are not necessarily
“wrong,” they do not reflect the typical expected output of LEDs once they are integrated into lighting fixtures. Although
percentages vary, it is not uncommon to see losses of 30 to 40%.
MYTH
Myth 4 3 Watt LEDs are brighter than 1 Watt LEDs
People are used to looking at wattage to determine the output of a light source. However, the wattage of an LED
FACT
is not directly comparable to either the wattage of a traditional light source or even from one LED to another.
Therefore, light output and light extraction efficacy, rather than raw wattage, are the key factors when looking at an
LED source.
Efficacy is the amount of light in lumens to the power used in watts or lumens per watt. Simply reporting the
number of watts does not reflect efficacy; two different LEDs can consume the same power but differ noticeably
in light output. Thus, when selecting LEDs or LED fixtures, it is more about light output, than power.
MYTH
Myth 5 LEDs generate no heat
When used in lighting applications, LEDs do not radiate infrared heat, only visible light. However, waste
FACT
heat is produced during the conversion of electricity into light and, if not properly removed from the
lighting system, may potentially damage the LEDs. The heat removal can be accomplished through
carefully engineered heat sinks that are built taking these thermal issues into account. The larger the
heat sink, the more efficiently and effectively heat is drawn away from the LED and dissipated into the
surrounding air.
MYTH
Myth 6 LED systems cost too much
The initial investment of LED systems is higher than that of conventional systems, but the return on
FACT
investment (ROI) for the use of LED lighting systems in an installation is surprisingly rapid when taking
maintenance and energy cost savings into consideration. Due to the long life of the LED, no lamp
replacement is required. With energy savings ranging from 50% to 70% compared to conventional light
sources, economic payback can be seen in less than two years. Additionally, the upfront cost of LED
systems is also continuing to drop rapidly.
12 13
Common LED myths
MYTH
Myth 7 LED light quality is poor
There are several measures used to describe light. Color temperature characterizes the color appearance
FACT
of a source and describes the apparent warmth or coolness of that light source. The Color Rendering
Index (CRI) is a metric used to measure the quality of light. The CRI for many white light LED systems is
typically between 70 to 85 (out of 100), and continues to improve rapidly, making it suitable for nearly all
lighting applications. CRI is currently the prevalent method for judging light quality.
MYTH
Myth 8 LEDs are not resistant to vibration
There are no moving parts, filaments or fragile glass enclosures required with LED lighting. LEDs are
FACT
therefore very suitable for use in road and bridge applications.
MYTH
Myth 11 LEDs can’t be dimmed and controlled
FACT
As LEDs are digital, they can therefore be easily dimmed to the required output. Using dimmable LED
drivers and a suitable control system, LEDs can be dimmed and manipulated in color temperature,
and intensity to suit the application requirements.
MYTH
Myth 12 LEDs have inconsistent color
FACT
The production process of LED is characterized by the fact that it is impossible to create LEDs that are
emitting the same color temperature within one batch. The threshold at which a color difference becomes
perceptible is defined by a MacAdam ellipse. A MacAdam ellipse is drawn over the color space in such a
way that the color at its center point deviates by a certain amount from colors at any point along its edge.
The scale of a MacAdam ellipse is determined by the standard deviation of color matching (SDCM). A color
difference of 1 SDCM “step” is not visible; 2 to 5 steps is barely visible; and 6 or more steps is noticeable.
MYTH
Myth 13 The color temperature of LEDs is always very cold, almost bluish
FACT
In the early days of LED, indeed LEDs were mostly on the cold side of the spectrum as this gave a higher
efficiency. Today, LEDs are available in a wide spectrum of color temperature (including road application),
ranging from 2700 Kelvin to 6500 Kelvin.
MYTH
Myth 14 The amount of lumen output is similar for both LED and
FACT conventional sources
When replacing conventional light sources with LED, there is a difference in lumen output required. For
example, 80W Mercury 3800 lumen can be replaced by 31W LED 2800 lumen. Conventional light sources
emit light over their complete surface, while LED only direct light in one direction. LED light sources are
therefore easier to use, as less reflectors and diffusers are required to direct the light to the right place
in the application. This results in a reduction of energy consumption as all these reflectors and diffusers
reduce the amount of light available for the application.
14 15
Common LED myths
MYTH
Myth 15 LEDs contain hazardous substances
FACT
LEDs, in comparison with high-pressure sodium, fluorescent or induction, do not contain mercury, lead or
other toxic materials and are completely recyclable.
MYTH
Myth 16 LED light affects Circadian Rhythm Cycle
The human body uses light cues—such as those provided by the sun—to time our internal functions.
FACT
These light cues also regulate mood, sleep, energy, appetite, and digestion. These daily internal cycles
are called circadian rhythms. Circadian rhythm cycle is stimulated by our eyes photoreceptor cell as
they measure the blue spectrum in the light. There is a small amount of blue light generated by a LED
system used for general purpose lighting, but it is a tiny fraction of the emissions when compared to
natural daylight. In short, a LED luminaire designed for general application does not have enough blue
spectrum to stimulate photoreceptor cell in our eye, thus it cannot influence our circadian rhythm.
COLOR TEMPERATURE
Moon & Starlight
Sunrise
Sunset
TIME OF DAY
MYTH
Myth 17 LED lights are more dangerous than natural light and are harmful to
FACT the eyes
The blue light photochemical retinal hazard is assessed on the basis of IEC standard 62471. It classifies
light sources into risk groups 0, 1, 2 and 3 (0 = low; 3 = high). Based on this classification, the sun
would fall into the high-risk groups 2 or 3, hence the recommendation to wear appropriate safety
glasses when looking into the sun for a long period. The LED lights for the consumer market from ELC
members, as with all other artificial light sources like traditional incandescent, halogen and energy
savers, fall into category 0 and 1. Thus, LED lighting products require no special measures for avoiding
blue light photochemical retinal hazard.
LED light is as safe to the eyes as any other artificial light sources. There is a small amount of blue light
generated by LED lamps. As a comparison, daily exposure to blue light on a summer day is at least
1,000 times stronger compared to artificial light indoors.
16 17
18
Areas of LED Applications Areas of LED Applications
Retail Healthcare
Office Education
Hospitality Residential
Industrial Outdoor
DL400 Downlight
Recessed Mounted Decorative
LED Downlight
Specifications
* Ceiling Type Plaster (board) ceiling * Driver External driver
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
Classification
70
IP20
Benefit
Ideal for making the switch from CFL to LED
145X145 (CUT-OUT)
165X165
DL351 Downlight
Recessed Mounted Decorative
LED Downlight
Specifications
* Ceiling Type Plaster (board) ceiling * Driver External driver
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
Classification
95
IP20
Benefit
Ideal for making the switch from CFL to LED
ø100 (CUT-OUT)
110X110
DL350 Downlight
Recessed Mounted Decorative
LED Downlight
Specifications
* Ceiling Type Plaster (board) ceiling * Driver External driver
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
Classification
IP20
70
Benefit
Ideal for making the switch from CFL to LED
ø175 (CUT-OUT)
ø195
DL200C-G2
Compact Down Light
Specifications
* Ceiling Type Plaster (board) ceiling * Driver Built-in
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
200
Classification
84
IP20
Benefit
Ideal for making the switch from CFL to LED
ø180
ø191
DL200M-G2
Mini Down Light
Specifications
* Ceiling Type Plaster (board) ceiling * Driver Built-in
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
200
General Lighting in corridors, offices and indoor circulation areas.
Classification
84
IP20
Benefit
Ideal for making the switch from CFL to LED
ø129 CUT-OUT
ø140
DL-300G2
Down Light
Specifications
* Ceiling Type Plaster (board) ceiling * Driver Built-in
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
200
General Lighting in corridors, offices and indoor circulation areas.
Classification
84
IP20
Benefit
Ideal for making the switch from CFL to LED Possible with Gold, Silver, White Trims.
ø186 CUT-OUT
ROF-600CG2
Commercial
Recessed “Drawn-in” Mounted
LED Commercial/Residential
Luminaire.
Specifications
* Ceiling Type Modular and Gypsum board ceiling * Driver Xitanium LED driver
* Voltage&
* Light Source Fortimo LED line Square 220-240V/50-60Hz
Frequency
Classification
IP20
540
595
574
Benefit
SUSPENSION ROD/CHAIN
Ideal for making the switch from Fluorescent to LED
HOUSING
53
574
DRAWN-IN MOUNTED CEILING
595
ROF-600MG2
Commercial
Recessed “Laid-in” Mounted
LED Commercial/Residential
Luminaire.
Specifications
* Ceiling Type 600x600 Metric, Modular ceiling * Driver Xitanium LED driver
* Voltage&
* Light Source Fortimo LED line Square 220-240V/50-60Hz
Frequency
Classification
IP20
575
595
Benefit
Ideal for making the switch from Fluorescent to LED
HOUSING
T-PROFILE
50,7
CEILING
575
595 LAID -IN MOUNTED
DL500 Down Light
Recessed Mounted LED Down Light.
Specifications
* Ceiling Type Plaster (board) ceiling * Driver Built-in
* Voltage&
* Light Source Fortimo LED module Integrated 220-240V/50-60Hz
Frequency
28 W (3000K)
* Power * Dimming No
27 W (4000K)
Application
General Lighting in corridors, offices and indoor circulation areas.
Classification
IP20
205
Benefit
Ideal for making the switch from CFL to LED
20
44
Specifications
* Type Adjustable Vesion * Remarks Internal optical unit 30° tiltable
* Voltage&
* Light Source Non replaceable LED module 220-240V/50-60Hz
Frequency
* Power 11 W * Dimming No
Application
Reception areas, Retails stores, Corridors, Toilets
Classification
IP44 (Optics) & IP20 (Control Gear)
Benefit
Ideal for making the switch from conventional lamp to LED
DA-800F
CoreLine Recessed LED Spot
20
54
Specifications
* Type Fixed version * Beam Angle 32°
* Voltage&
* Light Source Non replaceable LED module 220-240V/50-60Hz
Frequency
* Power 11 W * Dimming No
Application
Reception areas, Retails stores, Corridors, Toilets
Classification
IP54 (Optics) & IP20 (Control Gear)
Benefit
Ideal for making the switch from conventional lamp to LED
DL800
CoreLine Recessed
LED Downlight
65
Specifications
* Beam Angle 30° * Remarks
* Voltage&
* Light Source Non replaceable LED module 220-240V/50-60Hz
Frequency
Application
Reception areas, Retails stores, Indoor circulation areas
Classification
IP20
Benefit
Ideal to switch from Fluorescent to LED
ROF800
Recessed “Laid-in” Mounted
LED Commercial/Residential
Luminaire
20
Specifications
PSU (Power Supply Unit)PSD (Power
* Ceiling Type Metric, Modular ceiling * Driver Supply Unit with DALI interface)
* Voltage&
* Light Source Non-replaceable LED module 220-240V/50-60Hz
Frequency
Application
General lighting
Classification
IP20
Benefit
Ideal to switch from Fluorescent to LED
DL120
Recessed LED Downlight
180-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source Non replaceable LED module 180-240V/50-60Hz
Frequency
* Power 7W * Dimming No
- Housing: Aluminum
* Luminous Flux 560lm * Material
- Diffuser: Glass
General Information
* Color Rendering Index >80 * Emergency No
Total Voltage
Product Light
* Correlated Color Warm white: 3000K Top Level LED Lumen CRI CCT Watt Current Color Installation
* Color Body: White Number Color
Temperature Neutral white: 4000K Package /Cycle
* Maintenance of DL120/
* Optic Narrow beam WW 3000K
Lumen output L70B50 LED001 180-240V/
WH- R-
DL120 LED 560lm >80 7W 320mA
White Recessed
DL120/ 50-60Hz
* Beam Angle 24° * Connection 3-Pole Terminal block NW 4000K
LED002
Fixation by means of spring
* Drive Current 320mA * Installation
fasteners Ordering Samples: DL120/LED001 DL120/LED002
* Operating
24°
Temperature Range
Dimensional Drawing
Application
Reception areas, Retails stores, Indoor circulation areas
Classification
IP20
Benefit
Ideal to switch from CFL to LED Cut-out
Φ55mm
DL150
Recessed LED Downlight
180-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source Non replaceable LED module 180-240V/50-60Hz
Frequency
- Housing: Aluminum
* Luminous Flux 830lm * Material
- Diffuser: Glass
General Information
* Color Rendering Index >80 * Emergency No
Total Voltage
Product Light
* Correlated Color Warm white: 3000K Top Level LED Lumen CRI CCT Watt Current Color Installation
* Color Body: White Number Color
Temperature Neutral white: 4000K Package /Cycle
* Maintenance of DL150/
* Optic Narrow beam WW 3000K
Lumen output L70B50 LED001 180-240V/
WH- R-
DL150 LED 830lm >80 10W 300mA
White Recessed
DL150/ 50-60Hz
* Beam Angle 24° * Connection 3-Pole Terminal block NW 4000K
LED002
Fixation by means of spring
* Drive Current 300mA * Installation
fasteners Ordering Samples: DL150/LED001 DL150 / LED002
* Operating
Temperature Range
Dimensional Drawing
Application
Reception areas, Retails stores, Indoor circulation areas
Classification
IP20
Benefit
Ideal for switching over to LED Cut-out
Φ80mm
DL450
Recessed LED Downlight
180-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source Non replaceable LED module 180-240V/50-60Hz
Frequency
30W
* Power * Dimming No
50W
Dimensional Drawing
Application
Reception areas, Retails stores, Indoor circulation areas Product dimension
Wat A
Classification (W) (mm)
IP20
30 145
Benefit 50 150
Ideal to switch from CFL to LED Cut-out
Note: cut out is common for both.
Φ200mm
ROF400 LED Recessed
Recessed “Laid-in” Mounted LED
Commercial/Residential Luminaire.
220-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source LED 220-240V/50-60Hz
Frequency
Classification
IP20
Benefit
Ideal for switching over to LED
ROF400 LED Recessed
Recessed “Laid-in” Mounted LED
Commercial/Residential Luminaire.
220-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source LED 220-240V/50-60Hz
Frequency
Classification
IP20
Benefit
Ideal for switching over to LED
SP300 LED Step light
Recessed soft LED wall flood lights
110-230V
65
Specifications
* Voltage &
* Light Source LED 110V/230V
Frequency
450lm
* Luminous Flux * Material
350lm
General Information
* Color Rendering Index 80 * Emergency No
Total Voltage
Product Light
* Correlated Color Top Level LED Lumen CRI CCT Watt Optic Color Installation
Warm white: 3000K * Color Body: Grey Number color
Temperature Package /Cycle
DL-
* Maintenance of Diffuse lens (450lm)
* Optic SP300/LED001 450lm
Lumen output L70B50 Angled louvers (350lm) Diffuse
110V/ WM-
lens GR-
SP300 LED WW 80 3000K 12W
* Operating AL- Grey
* Connection 230V Wall mount
Temperature Range
SP300/LED002 350lm
Angled
* Drive Current 20mA * Installation Wall mount Louvres
Dimensional Drawing
Application
General lighting – outdoor circulations
Classification
IP65
Benefit
Ideal for switching over to LED
LB450 Canopy
Surface Mounted Indoor or
Outdoor LED Luminaire
65
Specifications
* Ceiling Type * Driver Built-in
* Voltage&
* Light Source Non Replaceable LED Module 120-277V/50-60Hz
Frequency
Classification
IP65
Benefit
Ideal for making the switch from CFL to LED
SOF-600G2
Commercial
Surface Mounted LED
Commercial/Residential
Luminaire.
Specifications
* Ceiling Type Concrete Ceiling * Driver Xitanium LED driver
* Voltage&
* Light Source Fortimo LED line Square 220-240V/50-60Hz
Frequency
Housing: Steel
* Luminous Flux 3150lm * Material
Frame: Extruded Aluminum
General Information
* Color Rendering Index >80 * Emergency No
Voltage Light
Warm white: 3000K Product
* Correlated Color LED Driver Lumen Watts CRI CCT Installation Color Option
Number
Neutral white: 4000K * Color Housing and Frame: White /Cycle Controller
Temperature
Cool White, Day Light: 6500K
3000K
Q-
* Lifetime 50Khrs @ 80°C Tcase Max, * Optic Lumieo Opal diffuser
34- 40- O-Opal W-
* Operating Terminal block inside fixture through SOF600-G2 P-Philips 3150 8-80 220-240V S-Surface
34.4W 4000K Diffuser White
Suitable for 25°C * Connection
Temperature Range 19-mm Ø hole on top of the housing /50,60/Hz
6500K
* Drive Current 350mA * Installation Surface Mounted
IP20 440
595
Benefit CEILING
HOUSING
Ideal for making the switch from Fluorescent to LED.
59
Ă19 CABLE ENTRY
595
FRAME
MOUNTING DETAILS
55
SOF800
Surface Mounted LED Commercial/
Residential Luminaire
20
Specifications
Individual; clicking the luminaire
* Beam Angle * Installation intopre-screwed ceiling brackets
* Voltage&
* Light Source Non-replaceable LED module 220-240V/50-60Hz
Frequency
* Correlated Color
Warm white: 3000K Neutral white: 4000K * Color White
Temperature 30- PSU- Power Supply Unit-
LED2700 3000K 220-240V /50-60Hz W60L60-597x597
* Lifetime 50,000 hours * Optic Polycarbonate cover E3- Emer. Pack 3 Hrs.
SOF800 8-80
Duration
LED3700 40- PSD- Power Supply with DALI- W20L120-197x1197
* Operating Temperature
Range +10 to +40°C [+10 to +40 °C] * Connection Push-in connector and pull relief 4000K 220-240V /50-60Hz
Application
General lighting
Classification
IP20
Benefit
Ideal to switch from Fluorescent to LED
FL400 Floodlight
Trunnion Bracket Mounted
Outdoor LED Luminaire
65
Specifications
* Ceiling Type * Driver Built-in
* Voltage&
* Light Source LED 120-277V/50-60Hz
Frequency
Classification
IP65
Benefit
Ideal for making the switch from HID to LED
CL300 Ceiling outdoor
Surface ceiling LED Light.
220-240V
50-60Hz
65
Specifications
* Voltage &
* Light Source LED 220-240V/50,60Hz
Frequency
- Housing: Aluminum
- Surface treatment: Dry powder
* Luminous Flux 840lm * Material polyester
General Information
- Diffuser: UV-Stabilizer
polycarbonate Total Voltage
Model Product Light
Top Level LED Lumen CRI CCT Watt Cover Color Installation
* Color Rendering Index >80 * Emergency No Name Number Color
Package /Cycle
* Correlated Color
Warm white: 3000K * Color Body: Black 220-240V S-
Temperature CL300/ O- BL-
PRIMO CL300 LED 840lm WW 80 3000K 12.5W Surface
LED001 Opal diffuser Black
/50,60Hz ceiling
* Maintenance of
50K-hr * Optic
Lumen output L70B50
Ordering Samples: CL300/LED001
* Operating
* Connection 3-Pole Terminal block
Temperature Range
Classification
IP65
Benefit
Ideal for switching over to LED
CL400 Ceiling outdoor
Surface ceiling LED Light.
220-240V
50-60Hz
65
Specifications
* Voltage &
* Light Source LED 220-240V/50,60Hz
Frequency
- Housing: Aluminum
- Surface treatment: Dry powder
* Luminous Flux 1520lm * Material polyester General Information
- Diffuser: UV-Stabilizer
polycarbonate Total Voltage
Model Product Light
Top Level LED Lumen CRI CCT Watt Cover Color Installation
Name Number Color
* Color Rendering Index >80 * Emergency No Package /Cycle
Classification
IP65
Benefit
Ideal for switching over to LED
CL500 Ceiling outdoor
Surface ceiling LED Light.
220-240V
50-60Hz
65
Specifications
* Voltage &
* Light Source LED 220-240V/50,60Hz
Frequency
- Housing: Aluminum
- Surface treatment: Dry powder
* Luminous Flux 580lm * Material polyester General Information
- Diffuser: UV- Stabilizer
polycarbonate Total Voltage
Model Product Light
Top Level LED Lumen CRI CCT Watt Cover Color Installation
Name Number Color
* Color Rendering Index >80 * Emergency No Package /Cycle
Classification
IP65
Benefit
Ideal for making the switch from HID to LED
DL160
Surface LED Downlight
180-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source Non replaceable LED module 180-240V/50-60Hz
Frequency
25W
* Power * Dimming No
50W
Dimensional Drawing
Application
Reception areas, Retails stores, Indoor circulation areas Product dimension
Wat A B
Classification (W) (mm) (mm)
IP20
25 170 170
Benefit 50 210 270
Ideal for switching over to LED
FL450 Architectural Flood light
Trunnion mounted LED Flood Light.
Available in different wattages
85-265V
65
Specifications
* Voltage &
* Light Source LED 85-265V
Frequency
* Luminous Flux
800lm, 1600lm, 2400lm, 4000lm, 5600lm,
* Material
-Die Cast Aluminum General Information
8000lm, -Toughened Glass
Voltage
* Color Rendering Index >75 * Emergency No Product Total Lumen Light
Top Level LED CRI CCT Watt Cover Color
Number Package Color
/Cycle
* Correlated Color Warm white: 3000K
* Color Body: Black FL450/LED001 WW 2800-3200K
Temperature Cool white: 5700K 800lm 10W
FL450/LED002 CW 6000-6500K
FL450/LED003 WW 2800-3200K
* Maintenance of 1600lm 20W
35Khrs * Optic 120° FL450/LED004 CW 6000-6500K
Lumen output L70B50
FL450/LED005 WW 2800-3200K 85-
2400lm 30W G- BL-
* Operating FL450/LED006 CW 6000-6500K
* Connection FL450 LED 75 265V/50-
Temperature Range FL450/LED007 WW 2800-3200K
4000lm 50W Glass Black
FL450/LED008 CW 6000-6500K 60Hz
* Drive Current 1.5A * Installation Trunnion FL450/LED009 WW 2800-3200K
5600lm 70W
FL450/LED010 CW 6000-6500K
FL450/LED011 WW 2800-3200K
8000lm 100W
FL450/LED012 CW 6000-6500K
Ordering Samples: FL450/LED001 FL450/LED002 FL450/LED003 FL450/LED004 FL450/LED005 FL450/LED006
FL450/LED007 FL450/LED008 FL450/LED009 FL450/LED010 FL450/LED011 FL450/LED012
70 340 287 78
20
Specifications
* Voltage &
* Light Source LED 220-240V/50-60Hz
Frequency
Classification
IP20
Benefit
Ideal for switching over to LED
SOF400 LED Surface
Surface “Laid-in” Mounted LED
Commercial/Residential Luminaire.
220-240V
50-60Hz
20
Specifications
* Voltage &
* Light Source LED 220-240V/50-60Hz
Frequency
Classification
IP20
Benefit
Ideal for switching over to LED
WPO700 LED Weatherproof
Surface Mounted LED Weatherproof
198-264V
65
Specifications
* Voltage &
* Light Source LED 198-264V
Frequency
230VAC
50-60Hz
22
Specifications
* Voltage &
* Light Source LED 230VAC/50-60Hz
Frequency
* Correlated Color
* Color White
Temperature
* Maintenance of
* Optic
Lumen output L70B50
* Operating
0°C-40°C * Connection
Temperature Range
Ordering Sample: AWEX000TTIGERLED2NM1
Surface (wall) Optional assembly in
* Drive Current - * Installation
dry-wall or ceiling bracket
Dimensional Drawing
Application
Offices, premises, rooms-doorways or passages
Classification
IP22
Benefit
Ideal for making the switch to LED
TWINS
Two-sided emergency exit signs
230VAC
50-60Hz
41
Specifications
* Voltage &
* Light Source LED 230VAC/50-60Hz
Frequency
* Correlated Color
* Color Silver/Black
Temperature
* Maintenance of
* Optic
Lumen output L70B50
* Operating
0°C-40°C * Connection
Temperature Range
Dimensional Drawing
Application
Offices, premises, rooms-doorways or passages
Classification
IP41
Benefit
Ideal for making the switch to LED
Helios DS LED
Two-sided emergency exit signs
230VAC
50-60Hz
42
65
Specifications
* Voltage &
* Light Source LED 230VAC/50-60Hz
Frequency
* Correlated Color
* Color White
Temperature
* Maintenance of
* Optic
Lumen output L70B50
* Operating
0°C-40°C * Connection
Temperature Range
Ordering Sample: AWEX000T00HDL3SAATP2
* Drive Current - * Installation Surface (ceiling)
Dimensional Drawing
Application
Offices, premises, rooms-doorways or passages
Classification
IP42 or IP65
Benefit
Ideal for making the switch to LED
HELIOS LED
One-sided emergency exit signs
230VAC
50-60Hz
42
65
Specifications
* Voltage &
* Light Source LED 230VAC/50-60Hz
Frequency
* Correlated Color
* Color White
Temperature
* Maintenance of
* Optic
Lumen output L70B50
* Operating
0°C-40°C * Connection
Temperature Range Ordering Sample: AWEX000T42HEL3SA000S
Surface (wall) Optional assembly
* Drive Current - * Installation
with wall or ceiling bracket
Dimensional Drawing
Application
Offices, premises, rooms-doorways or passages
Classification
IP42 or IP65
Benefit
Ideal for making the switch to LED
PLEXI LED
Two-sided emergency exit signs
230VAC
50-60Hz
20
Specifications
* Voltage &
* Light Source LED 230VAC/50-60Hz
Frequency
* Correlated Color
* Color White/Grey
Temperature
* Maintenance of
* Optic
Lumen output L70B50
* Operating
0°C-40°C * Connection
Temperature Range
Ordering Sample:AWEX000T00PLEXI22NM1
* Drive Current - * Installation Recessed (ceiling)
Dimensional Drawing
Application
Offices, premises, rooms-doorways or passages
Classification
IP20
Benefit
Ideal for making the switch to LED
WPO500 Industrial
Surface Mounted LED Weatherproof
220-240V
50-60Hz
65
Specifications
* Voltage &
* Light Source LED 220-240V/50-60Hz
Frequency
* Power 40 W * Dimming No
Classification
IP65
Benefit
Ideal for making the switch from CFL to LED
LB500 Low Bay
Pendant Mounted Low Bay Indoor
Industrial LED Luminaire
Specifications
* Ceiling Type * Driver Constant current LED control gear
* Voltage&
* Light Source Non Replaceable LED Module 220-240V/50-60Hz
Frequency
Q-
* Lifetime * Optic Built-in lens
C- 30- W-
* Operating LB500 T-Tridonic 3550 42-42W 9-90 220-240V P-Pendant
Citizen 3000K White
Suitable for 25°C * Connection Terminal is available outside
Temperature Range /50,60/Hz
Classification
1000
1000
Benefit FIXTURE
Ideal for making the switch from HID to LED.
345
345
ø445 ø445
HB700 LED High Bay Light
Side Ceiling / Suspension Mounted
High Bay Luminaire
220-240V
50-60Hz
65
Specifications
* Voltage &
* Light Source LED 220-240 V/50-60Hz
Frequency
150W
* Power * Dimming Yes
200W
16650lm
17325lm Housing: Die cast aluminum
* Luminous Flux
21400lm
* Material
Diffuser: Clear glass
General Information
22100lm
Voltage
Product Total Lumen
* Color Rendering Index >80 * Emergency No Top Level LED CRI CCT Watt Cover Color
Number Package
/Cycle
* Correlated Color Neutral white: 4000K
* Color Body: Black HB700/LED001 16650lm
Temperature Cool daylight: 6500K
4000K 150W
* Maintenance of HB700/LED002 17325lm 220-240V BL-
50Khrs * Optic Wide beam (120°) G-
Lumen output L70B50 HB700 LED 80
Glass
HB700/LED003 21400m /50,60/Hz Black
0.5m VDE/UL listed rubber cable 6500K 200W
* Operating
-30 – 45°C * Connection diameter of 3x1.0mm with cold- HB700/LED004 22100m
Temperature Range
pressed terminal
Dimensional Drawing
Application
Luminaires for Industry and High ceiling indoor.
Classification
IIP65
Benefit
Ideal for switching over to LED
BU300 Wall Light
Wall Mounted Bulkhead Indoor or
Outdoor LED Luminaire
54
Specifications
* Ceiling Type * Driver Built-in
* Voltage&
* Light Source Non Replaceable LED Module 120-277V/50-60Hz
Frequency
Classification
IP54
Benefit
Ideal for making the switch from HID to LED
AL300 Architectural light
(Square)
Wall/Surface ceiling Mounted
220-240V
54
Specifications
* Voltage &
* Light Source Replaceable LED Module 220-240V/50-60Hz
Frequency
4.5W
* Power * Dimming No
9W
Classification
IP54
Benefit
Ideal for switching over to LED
65
Specifications
* Voltage &
* Light Source Replaceable LED Module 220-240V/50-60Hz
Frequency
4.5W
* Power * Dimming No
9W
Classification
IP65
Benefit
Ideal for switching over to LED
67
68
Specifications
* Voltage &
* Light Source Replaceable LED Modules 110 – 277V/50-60Hz
Frequency
80W
* Power 100W * Dimming No
150W
8800lm
* Luminous Flux 10500lm * Material Housing: Die cast aluminum
General Information
17837lm
Total Voltage
Product
* Color Rendering Index >70 * Emergency No Top Level Lumen CRI CCT Watt Current Color Installation
Number
Package /Cycle
* Correlated Color Neutral white: 4000K SL700/LED001 4000K
* Color Body: Grey
Temperature Cool white: 5700K 8800lm 80W
SL700/LED002 5700K
* Maintenance of SL700/LED003 4000K GR- PS-
50Khrs * Optic Iso-Brightness 110 – 277V
Lumen output L70B50 SL700 10500lm 70 100W 860mA
SL700/LED004 5700K /50,60/Hz
Grey Post side
* Operating SL700/LED005 4000K
-40 – 50°C * Connection Direct male-female connection 17837lm 150W
Temperature Range
SL700/LED006 5700K
* Drive Current 860mA * Installation Post side; pole diameter 42-60mm Ordering Samples:SL700/LED001 SL700/LED002 SL700/LED003 SL700/LED004
SL700/LED005 SL700/LED006
Classification
IP68 LED modules
IP67 Power supply
Benefit
Ideal for switching over to LED
SL700/LED001-2-3-4 SL700/LED005-6
FL500 Landscape
9” Spike Mounted Outdoor LED
Luminaire
65
Specifications
* Ceiling Type * Driver Built-in
* Voltage&
* Light Source Replaceable LED Module 230V/60Hz
Frequency
Housing: PA
* Luminous Flux * Material
Diffuser: Tempered Glass
General Information
* Color Rendering Index 80 * Emergency No
Voltage Light
Product
* Correlated Color LED Driver Lumen Watts CRI CCT Installation Color Option
Number
Cool White: 4700K * Color Body: Black /Cycle Controller
Temperature
V-
* Lifetime 50 khrs * Optic Clear glass diffuser G-
B-
* Operating Electrical terminals available FL500 S 5-5W 8-80 3000K 230V
Glass Black
Suitable for 40°C * Connection
Diffuser
Temperature Range outside luminaire /60Hz
Classification
IP65
Benefit
Ideal for making the switch from CFL to LED
BL300 LED Buried light
High power LED in-ground flood lights
110V/230V
67
Specifications
* Voltage &
* Light Source LED 110V/230V
Frequency
1080lm
* Luminous Flux * Material
1320lm
General Information
* Color Rendering Index 70 * Emergency No
Total Voltage
Product Light
* Correlated Color WW) Warm white: 3000K Top Level LED Lumen CRI CCT Watt Color
* Color Body: Grey Number Color
Temperature (CW) Cool daylight: 6000K Package /Cycle
* Maintenance of
* Optic
Lumen output L70B50 BL300/LED001 1080lm WW 3000K
* Operating GR-
* Connection BL300 LED 70 15W 110V/230V
Temperature Range
Grey
Classification
IP67
Benefit
Ideal for switching over to LED
DW300 LED Drive Way light
Driveway series soft LED in-ground luminaires
110V/230V
68
Specifications
* Voltage &
* Light Source LED 110V/230V
Frequency
* Power 6W * Dimming No
410lm
* Luminous Flux 230lm * Material
150lm General Information
* Color Rendering Index 70 * Emergency No
Voltage
Product Total Lumen Light
Top Level LED CRI CCT Watt Color
* Correlated Color Number Package Color
Cool white: 6000K * Color Body: Grey /Cycle
Temperature
DW300/LED001 410lm
* Maintenance of
* Optic GR-
Lumen output L70B50 DW300/LED002 320lm
DW300 LED CW 70 6000K 6W 110V/230V
Grey
* Operating
-20° - 45° * Connection DW300/LED003 150lm
Temperature Range
Dimensional Drawing
Application
Walkways, pathways other outdoor circulations
Classification
IP68
Benefit
Ideal for switching over to LED
54
Specifications
* Voltage &
* Light Source Replaceable LED Module 220-240V/50,60Hz
Frequency
* Maintenance of
50K-hr * Optic
Lumen output L70B50 Ordering Samples: BO400/LED001
* Operating
* Connection 3-Pole Terminal block
Temperature Range
Classification
IP54
Benefit
Ideal for making the switch from HID to LED
BO300 LED Pillar light
Foot mounted Aesthetic Pillar
Outdoor Landscape Luminaire.
220-240V
50-60Hz
54
Specifications
* Voltage &
* Light Source Replaceable LED Module 220-240V/50,60Hz
Frequency
* Maintenance of
40K-hr * Optic
Lumen output L70B50 Ordering Samples: BO300/LED001
* Operating
* Connection 3-Pole terminal block
Temperature Range
Classification
IP54
Benefit
Ideal for switching over to LED