T10 @12"c/c rcc

both ways on top 1:2:4


GREASE TRAP
CLEANOUT COVER
HOUSE SEWER MAIN DRAIN SOLID PIPE WITH WATER-TIGHT 24" Sq.or 24" DIA OPEN VENTED TEE AT INLET
JOINTS (FIRST 6'-0" MIN.) FROM HOUSE SHOULD BE CAST IRON GRADE OPEN VENTED TEE AT OUTLET
CONCRETE COVER

12" TO
36"
LIQUIE LEVEL

1'6" 3"

1'
T10 @12"c/c

6"
4" DRAIN FROM on vertical
KITCHEN

1'6"
T8@12"c/c both face
on horizontal
1/2"cover on both face

12"
INTER COMPARTMENT

3'-0"
CONNECTION

24" SQUARE OR DETAIL


24" DIA CONCRETE T10 @12"c/c
COVER TYP. GREASE LAYER
ON TOP OF WATER both ways on top
45 YELBOW
3'x3' PRECAST CONCRETE
GREASE TRAP (OPTIONAL)

WAY CONNECTION LE INTERCOMPARTMENT VENT


NG
TH
OF INTERCOMPARTMENT
OPEN VENTED TEE SE CONNECTION
PT
IC
TA
NK 6" thick plain r.c.c
8'
CONCRETE COVER 1:2:4
WITH MORTAR CONNECTION

9" AIR SPACE


WATER

OPEN VENTED TEE


detail of reinforcement
9"

T10 @12"c/c
CAST IN SITE CONCRETE both ways on top rcc
SEPTIC TANK SOLID OUTLET PIPE 1:2:4

STANDARD SIZES WITH WATER-TIGHT


Min.
4'-0"

120 Cu.Fts. JOINTS T10 @12"c/c


on vertical

T8 @12"c/c both face


WATER FLOW OF CLARIFIED AND on horizontal
1/2"cover on both face
DIGESTED EFFLUENT (ABOUT 70%
SLUDGE PURIFIED) TO DISPOSAL SYSTEM
H
GT
7'-

T10 @12"c/c
SLUDGE
0

N
"

LE
both ways on top
PRIMARY SETTLING "
½
CHAMBER 7'-0" OF CAPACITY 3 '-7 Detail reinforcement of section A-A'
LY
BAFFLET TO SEPARATE PRIMARY FROM A TE
SECONDARY CHAMBER (FOR TANKS IM
OX
3'-

10"-0" OR GREATER) PR
0"

AP NOTE:-
1.Place House Sewer Below Frost Line.
SECONDARY SETTLING CHAMBER 2.Septic tank and grease traps are also made from
3'-0" OF CAPACITY concrete, coated steel, or thick-walled fiber glass.
3.Grease traps are not required unless there is a large
dietetic (kitchen disposal) discharge.
4.grease traps are only to be used if cleaned outperiodically.

SEPTIC TANK DETAILS