STRIP FOUNDATION (EN1997-1:2004)
1 Purpose of calculation
Design and alalysis of two leaf block basic strip foundation on a ridgid concrete base.

2 Calculation Reference
TEDDS Trial Software calulation version 3.1.04 - BS EN1997-1:2004 incorporating Corrigendum dated
February 2009 and the UK NA incorporating Corrigendum No.1.
3 Calculation Validation
Calculations checked by P.J.

4 Calculation Units
2
5 Sketch

Strip foundation details - considering a one metre strip


Length of foundation Lx = 1.00 m
Width of foundation Ly = 0.65 m
Foundation area A = 0.65 m² ###
Depth of foundation h = 0.20 m
Depth of block work hblock = 0.68 m
Depth of soil over foundation hsoil = 0.40 m
Level of water hwater = 0.00 m

Density of water ϒwater = 10.00 kN/m³


Density of block ϒblock = 15.00 kN/m³
Density of concrete ϒconc = 24.50 kN/m³

Cavity details
Width of cavity lcavity = 0.05 m

Wall no.1 details


Width of wall Iy1 = 0.1 m
Position in y-axis y1 = 0.25 m ###
Wall no.2 details
Width of wall Iy2 = 0.1 m
Position in y-axis y2 = 0.4 m ###

Soil Properties
Density of Soil ϒsoil = 18 kN/m³
Characteristic cohesion c'k = 0 kN/m²
Charac. angle of shear resistance φk = 30 ° φ'k = 0.5243 rads
Characteristic friction angle δk = 20 ° δk = 0.349 rads ###

Foundation loads
Self weight Fswt = 4.9 kN/m² ###
Soil Weight Fsoil = 7.2 kN/m² ###

Wall no.1 loads per linear metre


Self weight Fswt,w1 = 1.5 kN ###
Variable load in y-axis FQy1 = 3.5 kN
Permanent load in y-axis FGy1 = 0.0 kN
Variable load in z-axis FQz1 = 17.5 kN
Permanent load in z-axis FGz1 = 0.0 kN
Surcharge next to wall z-axis Fsur,z1 = 0.0 kN

Wall no.2 loads per linear metre


Self weight Fswt,w2 = 1.5 kN ###
Variable load in y-axis FQy2 = 0.0 kN
Permanent load in y-axis FGy2 = 0.0 kN
Variable load in z-axis FQz2 = 12.0 kN
Permanent load in z-axis FGz2 = 20.5 kN
Surcharge next to wall z-axis Fsur,z2 = 0.0 kN

Partial factors on actions 3


Permanent unfavourable action ϒG;dst = 1.00
Permanent favourable action ϒG;stb = 1.00
Variable unfavourable action ϒQ;dst = 1.30
Variable favourable action ϒQ;stb = 0.00

Partial factors for soil paramaters 3


Angle of shearing resistance ϒφ' = 1.25 NOTE: * denotes factor applied to tanφ (not to φ')

Effective cohesion ϒc' = 1.25


Undrained shear strength ϒcu = 1.40
Unconfined strength ϒqu = 1.40
Weight density ϒϒ = 1.00

Partial factors for spread foundations 3


Bearing ϒR;V = 1.0
Sliding ϒR;H = 1.0

Bearing resistance (Clause 6.5.2)

Forces on foundation per linear metre


Force in y-axis Fdy = 4.55 kN ###
Force in z-axis Fdz = 69.715 kN ###

Moments on foundation per linear metre


Perm. moments on x-axis MGdst;y = 11.731 kNm ###
Varia. Moments on x-axis MQdst;y = 11.928 kNm ###
Perm. moments on y-axis MGdst;x = 0 kNm ###
Varia. Moments on y-axis MQdst;x = 0.91 kNm ###
Sum of destabilizing moments ΣMdst = 24.569 kNm

Eccentricity of base reaction


Ecc. of base reaction in y-axis ey = 0.0274 m ###

Effective area of base per linear metre


Effective width Lˊy = 0.5952 m ###
Effective length L'x = 1.00 m
Effective area A' = 0.5952 m² ###

Pad base pressure


Design base pressure fdz = 117.13 kN/m² ###

Net ultimate bearing capacity under drained conditions (Annex D.4)


Design angle of shear resistance φ'd = 24.827 ° 0.4339 rads ###
Design effective cohesion c'd = 0 kN/m² ###
Effective overburden pressure q= 10.8 kN/m² ###
Design effective Ovr. Brdn. Prssr. q' = 8.64 kN/m² ###
Bearing resistance factors Nq = 18.317 ###
Nc = 37.373 ###
Nϒ = 16.049 ###
Foundation shape factors sq = 1.3254 ###
sϒ = 0.805 ###
sc = 1.3442 ###
Load inclination factors H = 4.55 kN ###
my = 1.6269 ###
mx = 1.3731 ###
m = 1.6269 ###
iq = 0.998 ###
iϒ = 0.9612 ###
ic = 0.9979 ###
Net ultimate bearing capacity nf = 275.87 kN/m² ###

Over design Factor Γ = 2.3551 ###

Sliding resistance (Clause 6.5.3)

Forces on foundation per linear metre


Force in y-axis Fdy = 4.55 kN ###
Force in z-axis Fdz = 31.365 kN ###

Sliding resistance verification per linear metre (Clause 6.5.3)


Horizontal force on foundation
Sliding resistance (exp 6.3b) RH;d = 11.416 kN ###

Over design Factor Γ = 2.509 ###