GE Oil & Gas

Zenith Surface Panel (ZSP)


The GE Zenith Surface Panel (ZSP) provides the interface for
communication with a downhole gauge and is common to the
Zenith E-Series, C-Series, R-Series and high temperature (HT)
downhole monitoring systems meaning only one type of data Pi - 28/07/07 14:00:00

acquisition unit is required when Zenith systems are installed. This


0.8

0.6

0.5

simplifies maintenance and provides common communication of


0.4

0.3

0.2

data from well site to varying forms of data transmission devices 0.1

0.0
28/07/07
02:00:00
28/07/07
06:00:00
28/07/07
10:00:00
28/07/07
14:00:00
TI M E

such as SCADA.
PA R AM 1 2 Ho u r s B ACK NEXT
FR AM E

The panel contains a display and keypad for local information and
can be connected to surface drives to provide automated shut-
down signals in addition to alarms protecting lift systems and well
integrity.
The flexible design of the panel allows mounting inside or
outside of cabinet doors. Panels for low ambient temperature
environments can be produced on request. Additional analogue
input and output cards can also be added as required.
ZSP Lite is available as an alternative for E-Series monitoring
systems - see specifications below. Note: when ZSP / ZSP Lite
is interfacing with E-Series ESP monitoring systems, a Zenith
surface choke will be required.

Data Gathering Construction

Data logging 4MB internal capacity (59MB on ZSP Lite) General Fits inside or outside switch board or VSD. IP66 enclosure
- min 32,000 downhole records (1,000,000 on ZSP Lite)
Material Aluminium
2GB SD card
- simple data transfer to removable memory card Display 320 x 240 graphical touch-screen display and keypad
Smart logging available if extended periods required
Dimensions 200 x 230 x 110 mm
Engineers’ port External engineers’ port for easy access
Temperature rating 65°C continual use
Data transfer (SCADA) Modbus interface ready to interface to SCADA type
systems
Power Requirements
Analogue inputs 8 x 4-20mA (2 x 4-20mA on ZSP Lite)
Power supply 85-264V AC
Modbus port Included as standard RS232/485 1,200-38,400 Baud
Frequency 50-60Hz +/- 10%
rates (isolated RS232/485 300-115,000 Baud rates on
ZSP Lite) Nominal power 30W (20W on ZSP Lite)
Features Hand-held PDA or laptop PC connection to engineers’ Fuse rating 3 Amp (2 Amp on ZSP Lite)
port over ethernet

Communications Up to 38,400 Baud rate (115,000 on ZSP Lite) Gauge Functionality


Interface Standard 6 pin round rugged military connector Output gauge supply 120 VDC current limited or 24 VDC current limited
(waterproof ethernet connector on ZSP Lite)
Alarm & trip relay 250VAC/DC 1A volt free SPCO activated by all readings
(5A on ZSP Lite)

Analogue outputs 8 x 4-20mA (2 x 4-20mA on ZSP Lite)


MODBUS Alarms Analogue Removable
Description Ref. No. Display Data Logger Event Logger RS232/485 & Trips In/Out Memory

ZSP Lite for E-Series gauges 14460240002       

ZSP Lite for C-Series & R-Series 14460240005       

ZSP for E-Series gauges 14460110002       

ZSP for E-Series with 1-sec 14460110016       


mapping for intake pressure

ZSP for C-Series gauges: C2 14460110008       

ZSP for C-Series gauges: C5/C6 14460110005       

ZSP for R-Series gauges 14460110012       

ZSP for HT c/w PSU & cable kit 14460301010       

Description Ref. No. ZSP Lite Surface Choke PSU for HT-ZSP

Zenith surface choke 14460052000

Installation cable kit 14460003000


Pi - 28/07/07 14:00:00
0.8

0.6

0.5

0.4

0.3

0.2

0.1

0.0
28/07/07 28/07/07 28/07/07 28/07/07
02:00:00 06:00:00 10:00:00 14:00:00
TIM E PA R AM BAC K NEXT
F R AM E 12 H o u r s

F1 F2 F3 F4 F5

geoilandgas.com/artificiallift
©2015 General Electric Company. All Rights Reserved.
AL15-KGDRAFT-EN-REV00

Das könnte Ihnen auch gefallen