Sie sind auf Seite 1von 6

CCC AND CTR

CENTRAL COORDINATION CENTER COUNTER-TERRORISM RESPONSE (CTR) SUITE


SIZE MIN. 42 SQM MIN. 88 SQM

NUMBER
REQUIRED 2 1

Single level facilities: Centrally located between primary processing and baggage claim
with a clear view of both areas.
LOCATION Multi-level facilities: Centrally located directly beyond primary processing. Located adjacent to the PPA.

FIXED Built-in 30” height work counters with knee space, lockable drawers, low storage cabinets,
EQUIPMENT and 2 drawer files. See individual room specifications (interview / search / hold,etc.).

FIRE Pop-down sprinkler heads. See hold room and search room specifications for detention
PROTECTION Pop-down sprinkler heads. grade requirements.

SECURITY
SYSTEM CCTV, ACCESS CONTROL & DURESS SYSTEM CCTV, ACCESS CONTROL & DURESS SYSTEM

Floor: Carpeted floor raised 22” above processing and / or baggage claim floor. Floor: Carpeted
CONSTRUCTION Walls: 5 / 8” gypsum board over metal studs. STC rating 50-55. Walls: 5 / 8” gypsum board over metal studs. STC rating 50-55.
& FINISHES Ceiling: 5 / 8” gypsum board (acoustical tile not permitted). STC rating 50-55. Ceiling: 5 / 8” gypsum board (acoustical tile not permitted). STC rating 50-55.

FURNITURE Chairs. As specified in the individual room specifications

Normal convenience power standards. Data ports. Dedicated computer circuits.


Normal convenience power standards. Dedicated Emergency power backup. Lighting: Recessed incandescent lighting w / dimmer control.
computer circuits. Emergency power backup. Separate room lighting requirements to be followed as specified in the individual room
Lighting: Recessed incandescent lighting w / dimmer specifications (interview room, search room, hold room, office, etc. located within these
ELECTRICAL control. Workstation task lighting. standards).

Material: 1 ¾” wood or hollow metal in hollow metal frame (no window). Material: 1 ¾” wood or hollow metal in hollow metal frame (no window).
Hardware: Card reader / keypad ingress. Electric pushbutton egress. Locate pushbuttons at Hardware: Card reader / keypad ingress. Electric pushbutton egress. Locate pushbuttons at
DOOR entry door and near alarm workstation(s). entry door and near alarm workstation(s).

Material: Tempered clear glass with reflective mirror film on the public side to preclude
observation of CBP operations within. No window treatment. Maximize glass area above
WINDOWS counter. Material: Tempered transparent mirror glass. No window treatment. Maximize glass area.

PROVIDED
EQUIPMENT Enforcement computers, printer, telephones, fax machine, two-way base radio. Enforcement computers, enforcement printer, telephones, fax machine.