Philips FAST SpO2 Option A01 and Philips Sensors — 8-pin connector
With these monitors, the following sensors and adapters are validated
M1196T Pediatric/
M1193T Neonatal Adult Clip
(0.90 m) (0.90 m)
M1194A Ear Clip M1195A Infant
(1.5 m) (1.5 m)
M1133A Neontal/
M1191AL/BL (3 m) Adult M1196A (3 m) Pediatric/Adult Clip Adult/Infant
Extra long sensor cable length Extra long sensor cable length (0.90 m)
Reusable
Single-patient-use
Philips FAST SpO2 Option A01 and Masimo® Sensors
With these monitors, the following sensors and adapters are validated
M3000A/M3001A MMS
M1020B M3002A MMS X2 M8102A MP2 M8105A MP5
9898031 40321 9898031 40331 9898031 40341 9898031 48281 9898031 48291 9898031 48301
Adult (DCI) Pediatric (DCIP) Adult (TC-I) Adult (DC-I) Pediatric (DC-IP) Adult (TC-I)
9898031 40231 9898031 40261 9898031 40311 9898031 48231 9898031 48241 9898031 48251
Adult (Adt) Pediatric (Pdt) Infant (Inf-L) Adult (Adtx) Pediatric (Pdtx) Infant (Inf-L)
9898031 40321 9898031 40331 9898031 40341 9898031 48281 9898031 48291 9898031 48301
Adult (DCI) Pediatric (DCIP) Adult (TC-I) Adult (DC-I) Pediatric (DC-IP) Adult (TC-I)
9898031 40231 9898031 40261 9898031 40311 9898031 48311 9898031 48231 9898031 48241
Adult (Adt) Pediatric (Pdt) Infant (Inf-L) Adult (TF-I) Adult (Adtx) Pediatric (Pdtx)
9898031 40291 9898031 40271 9898031 40301 9898031 48251 9898031 48261 9898031 48271
Neonatal (Neo-L) Neonatal (Neo) Neonatal (Neo Pt-L) Infant (Inf-L) Neonatal (Neo Pt-L) Neonatal (Neo-L)
9898031 40281
Neonatal (Neo Pt)
Philips SpO2 CMS / Viridia >/= Rev. C (legacy HP/Agilent) 12-pin input connector
With this module, the following sensors and adapters are validated
M1020A Module
Adapter cable required Adapter cable required Adapter cable required
Adapter cable M1940A (2 m) Adapter cable M1900B (3 m) Adapter cable M1020-61102 (3.6 m)
(12-pin to 8-pin connector) (12-pin to 9-pin connector) for Masimo LNOP Sensors
M1133A Neontal/
Adult/Infant
M1191AL/BL (3 m) M1196A (3 m) (0.90 m)
Adult Pediatric/Adult Clip
Extra long sensor Extra long sensor 9898031 40291 9898031 40301
cable length cable length Neonatal (Neo-L) Neonatal (Neo Pt-L)
Philips FAST SpO2 Option A01 and Nellcor Sensors — 8-pin connector
With these monitors, the following sensors and adapters are validated
Connect to these adhesive sensors (only available from Philips in Europe and Japan)
Philips SPO2 CMS / Viridia >/= Rev. C (legacy HP/Agilent) 12-pin input connector
With these monitors, the following sensors and adapters are validated
M1020A Module
M1900B (3 m)
Connect to these adhesive sensors (only available from Philips in Europe and Japan)
© 2008 Koninklijke Philips Electronics N.V. Philips Healthcare is part of Royal Philips Electronics
All rights are reserved.
www.philips.com/healthcare Philips Healthcare
healthcare@philips.com Global Information Center
3KLOLSV+HDOWKFDUHUHVHUYHVWKHULJKWWRPDNHFKDQJHVLQVSHFLÀFDWLRQV fax: +31 40 27 64 887 P.O. Box 1286
and/or to discontinue any product at any time without notice or obligation 5602 BG Eindhoven
and will not be liable for any consequences resulting from the use of this Printed in The Netherlands The Netherlands
publication. 4522 962 39921 * NOV 2008