A-105 Standard specification for forgings, carbon D 2444 Test for impact resistance of
steel, for piping components thermoplastic pipe and fittings by means
of a tup (falling weight)
A-125 Standard specification for steel springs,
helical, heat-treated D 2837 Obtaining hydrostatic design basis
thermoplastic pipe materials
A-126-73 Standard specification for gray iron
castings for valves, flanges, and pipe D 2924 Test for external pressure resistance of
fittings plastic pipe
FHA UM-49 ABS and PVC plastic drainage and vent SBCC
pipe and fittings, FHA 4550.49 Southern Building Code Congress
1166 Brown-Marx Building
FHA UM-53a Polyvinyl chloride plastic drainage, waste Birmingham, Alabama 35203
and vent pipe and fittings SBCC Southern Standard Plumbing Code
FHA MR-562 Rigid chlorinated polyvinyl chloride SIA
(CPVC) hi/temp water pipe and fittings Sprinkler Irrigation Association
FHA MR-563 PVC plastic drainage and vent pipe and 1028 Connecticut Avenue, N.W.
fittings Washington, DC 20036
Minimum Standards for Irrigation Equipment
FHA Minimum Property standards interim revision No. 31
WUC
IAPMO Western Underground Committee, W.H. Foote
International Association of Plumbing and Los Angeles Department of Water and Power
Mechanical Officials P.O. Box 111
5032 Alhambra Avenue Los Angeles, California 90054
Los Angeles, California 90032 Interim Specification 3.1: Plastic Conduit and Fittings
Uniform Plumbing Code UL
IAPMO IS8 Solvent cemented PVC pipe for water Underwriters Laboratories, Inc.
service and yard piping 207 East Ohio Street
Chicago, Illinois 60611
IAPMO IS9 PVC drain, waste, and vent pipe and fit- UL 651 Rigid Nonmetallic Conduit (September 1968)
tings UL 514 Outlet Boxes and Fittings (March 1951 with
IAPMO IS10 Polyvinyl chloride (PVC) natural gas Amendments of 22-228-67)
yard piping Table 3 - PIPE O.D.s
IAPMO PS27 Supplemental standard to ASTM D2665; U.S. (ANSI) EUROPE (ISO)
polyvinyl chloride (PVC) plastic drain, NOMINAL ACTUAL DN d
waste, and vent pipe and fittings BORE OD (NOMINAL BORE) (ACTUAL OD)
(NOTE: IS = installation standard; PS = property standard) INCHES INCHES MM IN. MM IN.
1/8 .405 6 (.236) 10 (.394)
NSF
National Sanitation Foundation 1/4 .540 8 (.315) 12 (.472)
School of Public Health 3/8 .675 10 (.394) 15 (.630)
University of Michigan 1/2 .840 15 (.591) 20 (.787)
Ann Arbor, Michigan 48106
3/4 1.050 20 (.787) 25 (.984)
NSF 1 1.315 25 (.984) 32 (1.260)
Standard No. 14: Thermoplastic Materials, Pipe, Fittings,
Valves, Traps, and Joining Materials 1 1/4 1.660 32 (1.260) 40 (1.575)
1 1/2 1.900 40 (1.575) 50 (1.969)
NSF
Seal of Approval: Listing of Plastic Materials, Pipe, Fittings, 2 2.375 50 (1.969) 63 (2.480)
and Appurtenances for Potable Water 2 1/2 2.875 65 (2.559) 75 (2.953)
and Waste Water (NSF Testing 3 3.500 80 (3.150) 90 (3.543)
Laboratory).
4 4.500 100 (3.937) 110 (4.331)
NSPI 5 5.563 125 (4.921) 140 (5.512)
National Swimming Pool Institute
6 6.625 150 (5.906) 160 (6.299)
2000 K Street, N.W.
Washington, DC 20006 8 8.625 200 (7.874) 225 (8.858)
T.R.-19 The Role of Corrosion-Resistant Materials in 10 10.750 250 (9.843) 280 (11.024)
Swimming Pools, Part D, The Role of Plastics in 12 12.750 300 (11.811) 315 (12.402)
Swimming Pools.
Type 1 General Purpose - Indoor: This enclosure is Type 5 Superseded by Type 12 for Control Apparatus.
intended for use indoors, primarily to prevent
accidental contact of personnel with the Type 6 Submersible, Watertight, Dusttight, and Sleet
enclosed equipment in areas where unusual (Ice) Resistant - Indoor and Outdoor: Type 6
service conditions do not exist. In addition, they enclosures are intended for use indoors and
provide protection against falling dirt. outdoors where occasional submersion is
encountered, such as in quarries, mines, and
Type 2 Dripproof - Indoor: Type 2 dripproof enclosures manholes. They are required to protect
are for use indoors to protect the enclosed equipment against a static head of water of 6
equipment against falling noncorrosive liquids feet for 30 minutes and against dust, splashing
and dirt. These enclosures are suitable for or external condensation of non-corrosive
applications where condensation may be liquids, falling or hose directed lint and
severe such as encountered in cooling rooms seepage. They are not sleet (ice) proof.
and laundries.
Type 7 Class I, Group A, B, C, and D-Indoor
Type 3 Dusttight, Raintight, Sleet (Ice) Resistant Hazardous Locations - Air-Break Equipment:
Outdoor: Type 3 enclosures are intended for Type 7 enclosures are intended for use
use outdoors to protect the enclosed indoors, in the atmospheres and locations
equipment against windblown dust and defined as Class 1 and Group A, B, C or D in
water. They are not sleet (ice) proof. the National Electrical Code. Enclosures must
be designed as specified in Underwriters’
Type 3R Rainproof and Sleet (Ice) Resistant Outdoor: Laboratories, Inc. “Industrial Control Equipment
Type 3R enclosures are intended for use for Use in Hazardous locations,” UL 698. Class I
outdoors to protect the enclosed equipment locations are those in which flammable gases
against rain and meet the requirements of or vapors may be present in explosive or
Underwriters Laboratories Inc., Publication No. ignitable amounts. The group letters A, B, C,
UL 508, applying to “Rainproof Enclosures.” and D designate the content of the hazardous
They are not dust, snow, or sleet (ice) proof. atmosphere under Class 1 as follows:
4
COMPLETE SIGNAL SIGNAL-
SIGNAL-
4
BLUE YELLOW
4 2 3
2 3 W
2 3
Figure 1. For use where specified color Figure 2. For use where a white back- Figure 3. For use where a white back-
background is used with numerals of con- ground is necessary. ground is used with painted numerals, or
trasting colors. for use when the signal is in the form of
sign or placard.
IDENTIFICATION OF MATERIALS BY
HAZARD SIGNAL ARRANGEMENT
4
2 3 This is a system for the identification of hazards to life
and health of people in the prevention and control of
fires and explosions in the manufacture and storage of
materials.
50 FEET 1"
75 FEET 2" NOTE:
This shows the correct spatial arrangement and order of signals
100 FEET 3"
used for identification of materials by hazard.
200 FEET 4"
300 FEET 6"
4
3 2
W
SPECIFIC HAZARD
Oxidizer OXY REACTIVITY
Acid ACID 4 - MAY DETONATE
Alkali ALK 3 - SHOCK AND HEAT MAY DETONATE
Corrosive COR 2 - VIOLENT CHEMICAL CHANGE
Use NO WATER W 1 - UNSTABLE IF HEATED
0 - STABLE
Radiation Hazard
(PTFE)
(PFA) POLYFLUOROALKOXY
(FEP)
(PTFE)
(FEP) FLUORINATED