Beruflich Dokumente
Kultur Dokumente
XU Photoelectric Sensors
File 9006
CONTENTS
Description Page
Selection and Application Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
XUB 18 mm Cylindrical Metal and Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
XUM Miniature Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
XUK SubCompact 50 x 50 Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
XUX Compact Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
XUD Fiber Optic Amplifier Self Teach. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Schneider Electric Brands Classic / Application Specific and Other. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Operation and Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors
10
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors
XUM Classic XUMA XUM XUK XUK XUK XUC XUL XUJL
High-Performance Multi-Mode Multi-Mode Classic Economy
Miniature Miniature Miniature SubCompact SubCompact Compact SubCompact Standard
SubCompact
Rectangular Rectangular Rectangular Universal Universal Universal Rectangular Rectangular
Plastic Plastic Plastic Plastic Plastic Plastic Plastic Plastic Plastic
1, 3, 4, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X, 6, 6P, 12, 13 1, 3, 4, 6, 6P, 12, 13 1, 3, 6, 12, 13
IP67 IP67 IP67 IP65 IP65 IP65 IP67 IP67 IP67
33 ft (10 m) 45.9 ft (14 m) 26 ft ( 8 m) 98 ft (30 m) 98.4 ft (30 m) 98.4 ft (30 m) 196 ft (60 m) 33 ft (10 m) 65.6 ft (20 m)
8 ft (2.5 m) 9.8 ft (3 m) 6.6 ft (2 m) 16 ft (5 m) 13 ft (4 m) 19.7 ft (6 m) 29.5 ft (9 m) 16 ft (5 m) 24 ft (7.3 m)
13 ft (4 m) — 13 ft (4 m) 30 ft (9 m) 2.6 ft (0.8 m) 32.8 ft (10 m) — 25 ft (8 m) 33 ft (10 m)
3 ft (0.9 m) / 5 in (0.13 m)
15.7" (40 cm) /
Convergent Beam 0.6 in 15.7" (40 cm) 3.3 ft (1m) 11.8" (300 mm) 4.9 ft (1.5 m) 3.9 ft (1.2 m) adj 2.3 ft (.7 m) —
3.9" (10 cm)
(15 mm)
No No No No No — — No No
DC DC DC DC DC, AC/DC AC/DC, DC AC/DC, DC AC/DC, DC AC/DC
98 46 48 52 50 100 102 104 106
-
+
XUE XUFN XUD XUD Plus XUDA1 XUDA2
Classic Classic Self-Teach Self-Teach
Amplifier for Fiber Optic Universal Amplifier
Plastic Fiber Optic Cables Fiber Optic Amplifier Fiber Optic Amplifier
XUFA Fiber Optics Amplifier for Fiber Optics
Plastic Plastic Plastic Plastic Plastic Plastic
– – 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13 1, 3, 4, 6, 12, 13
IP40 – IP66 IP66 IP66 IP66
see Fiber Optics 9.84 in (250 mm) see Fiber Optics see Fiber Optics see Fiber Optics see Fiber Optics
– – – – – –
– – – – – –
see Fiber Optics 3.44 in (87 mm) see Fiber Optics see Fiber Optics see Fiber Optics see Fiber Optics
Yes – – – – –
AC/DC – – – DC DC
118 120 124 124 58 58
11
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors
12
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide
Selection Guide
Photoelectric Sensors
XU 18 mm XU 18 mm XU 18 mm XUM XURK XURK
Laser High Excess Gain Analog Color Mark Color Mark Registration Self Teaching Color Mark
Plastic Nickel Plated Brass Nickel Plated Brass Plastic Die Cast Zinc Die Cast Zinc
— 3, 4, 4X, 6, 12, 13 3, 4, 4X (indoor), 6, 12, 13 1, 3, 4, 6, 6P, 12, 13 — —
IP67 IP67 IP67 IP67 IP67 IP67
328 ft (100 m) 229.6 ft (70 m) — — — —
— — — — — —
— — — — — —
— — 2 to 15.7 in (50 to 400 mm) 0.6 in (15 mm) 0.354 in (9 mm) 0.354 in (9 mm)
No — — No No No
DC DC PNP Analog DC DC DC
90 84 86 134 138 140
— — — —
— — — —
— — — —
No No No No
DC DC DC DC
146 148 150 152
13
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications
Packaging Machinery
Transparent Material Detection Opaque Color Mark Registration
Label Detection
Reading reference marks for trimming
D
L
OUTPUT
Photoelectric Sensors
Material Handling
Long Range Analog
Sensing
Detecting cakes
XU 18 mm XUC XU 18 mm XU 18 mm XUJ
High Excess
Style Laser (pair) Thru-Beam Analog Analog
Gain
Material ABS/PMMA Plastic Nickel Plated Brass Nickel Plated Brass Plastic
Housing NEMA Type – 3, 4, 4X, 6, 6P, 12, 13 3, 4, 4X, 6, 12, 13 3, 4, 4X (indoor), 6, 12, 13 1, 3, 6, 12, 13
CENELEC Type IP67 IP67 IP67 IP67 IP67
Thru-beam 328 ft (100 m) 196 ft (60 m) 229.6 ft (70 m) — —
Maximum Retro reflective Polarized — 29.5 ft (9 m) — — —
Sensing Non-polarized — — — — —
Range
Proximity Diffuse 2 to 15.7 in 7.87 to 31.5 in
— 3.9 ft (1.2 m) adj —
(Standard/Short Range) (50 to 400 mm) (20 to 80 mm)
Glass Fiber Optics Option No No — — —
Output DC AC/DC, DC DC PNP Analog PNP Analog
Page 90 102 84 86 110
14
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications
Photoelectric Sensors
XU 18 XURU XURC3 XURC4 XUFN
Fiber Optic Convergent Beam
Ultra Violet Ultra Violet Self Teach Full Color Detector
Full Color Detector Fiber Optic Cables
Nickel Plated Brass Die cast zinc Aluminum Aluminum Plastic
— — — — —
IP67 IP67 IP67 IP65 —
— — — — 1.18 in Convergent (30 mm)
— — — — —
— — — see Fiber Optics —
0.787 in (20 mm) 0.787 in (20 mm) 1.57 to 2.36 in (40 to 60 mm) see Fiber Optics —
No No Yes Yes —
DC DC DC DC —
88 142 144 144 122
15
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications
Assembly Equipment
Miniature Separate Optical Heads and Amplifiers Fiber Optics and Amplifiers
Verifying plate feed
Photoelectric Sensors
Harsh Environment
Washdown Metal Bodies
16
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Selection Guide for Specific Applications
Selection Guide for Specific Applications
Photoelectric Sensors
XUFNkP XUFNkS XUFNkT XUFNkL XUVF XUVF
3.9 ft (1.2 m) adj 3.44 in (87 mm) 5.9 in (15 cm) 2.75 in (70 mm)
— — — —
AC/DC, DC — — —
102 120 116 122
17
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples
XUVF••0M12 XUMH023539
18
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples
07: Monitoring height of lipsticks prior to capping 08: Monitoring flow of pallets carrying bottled water
Photoelectric Sensors
XU2B18•P340 XUJK06353
XUJK063539 XUL•153538
11: Verifying correct seating of screw 12: Monitoring flow of objects exiting vibrating bowl
Off On
19
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples
XUB•01353 XUM•15353•
15: Detecting dark colored objects on conveyor 16: Monitoring alignment of glass panes
XUJK703538 XUB•01353
20
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples
Photoelectric Sensors
XUJK803538 (analog) XUL•153538
XUJK703538 XUL•043539
21
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples
XUVK0252 XUV•003530
29: Verifying presence of cakes in transparent packaging 30: Detecting incorrect positioning of label
22
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples
31: Reading reference marks for trimming 32: Detecting “end of roll”
D
L
OUTPUT
Photoelectric Sensors
XURK0955D XUM•103535
XUL•153538 XU2P18•P340DL
23
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Application Examples
Application Examples
37: Monitoring position of tooth brushes 38: Monitoring stock level in hopper
Photoelectric Sensors
XUV•003530 XUD•003537
39: Monitoring cake position prior to packaging 40: Monitoring positioning of book cover
24
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Application Examples
Application Examples
43: Detecting bottles filled with mineral water 44: Zone surveillance
Photoelectric Sensors
XUL•153538 XU2P18•P340DL
XULM06031H60 XULM06031H60
25
10/02 ©1997- 2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Interpretation of Catalog Numbers
Interpretation of Catalog Numbers
X U X O A K S A T 1 6 • • • •
BODY STYLE
8mm cylindrical A
18mm cylindrical B
Stubby 40x40 C
Amplifier D
Rectangular Compact E
Fiber optic F
Compact Rectangular J
Photoelectric Sensors
26
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Interpretation of Catalog Numbers
Interpretation of Catalog Numbers
Photoelectric Sensors
Proximity Diffuse with Background Suppression 8
Polarized Retroreflective 9
ENCLOSURE TYPE
Plastic with Sensitivity Adjustment B
Metal with Sensitivity Adjustment M
Metal N
Plastic P
DIAMETER
18mm diameter 1 8
OUTPUT
Analog A
2 wire AC/DC M
3 wire DC, NPN N
3 wire DC, PNP P
Ultra Violet U
OPERATION MODE
Dark Operate A
Light Operate B
Light and Dark Operate P
WIRING
2 Wire 2
3 Wire 3
AC/DC without Short Circuit Protection 3
DC with Short Circuit Protection 4
MISCELLANEOUS
DC Micro Style Connector D
Laser Sensor with Micro Style Connector DL
AC/DC Micro Style Connector K
5 Meter Cable L5
10 Meter Cable L10
Separate Thru-Beam Receiver R
Separate Thru-Beam Emitter T
90 ° Side Sensing W
NOTE: These tables are intended to understand catalog number designations. They are NOT
to be used to create numbers which may not exist. Consult your local field office.
27
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
Multi-Mode Technology
Multi-Mode Technology
Principle
c A single product that automatically adapts to every use.
YW
Telemecanique offers this major innovation: Osiconcept - Offering simplicity through
innovation.
1
Photoelectric Sensors
S max.
YW
c With Osiconcept, by simply clicking on the teach button, the product is automatically
configured for optimal use based on the application.
1. Diffuse proximity sensing with no accessories.
S max.
2 2. Diffuse proximity sensing with background suppression, with no accessories.
3. Polarized retroreflexive sensing with a reflector accessory.
YW
4. Thru-beam sensing with thru-beam accessory.
3 S max.
c But in addition, Osiconcept offers:
d the maximum range for each environment,
YW
d a tenfold reduction in the number of separate products needed.
S max.
4 c The first sensor of its kind in the world for enhancing productivity.
c A complete offering that resolves the most common sensing problems:
d simplify your options,
d simplify your product inventories,
d simplify installation,
YW d simplify maintenance.
2 1. Output activated
YW 2. Output activated
3. Output activated
NOTE: Reverse operation is available simply by pressing the "teach" button.
3
Installation
c 3D attachment kits provide quick installation or adjustment of Osiconcept photoelectric
sensors on 3 axes.
d These kits can also be used to install reflectors.
d They include a set of brackets, screws and covers that can be used to install all new
enclosures in the Osiris product line.
28
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
Multi-Mode Technology
XS Inductive Sensors - Auto-Adaptable Technology
Cylindrical
Dimensions " (mm) 0.71 (18)
Photoelectric Sensors
Applications Machine Building, Packaging, Counting, Conveyor
Ranges in Meters
with emitter accessory 20
with reflector accessory 4
diffuse without accessory 0.4
Diffuse w/bgs without accessory 0.12
Body style XUB
Pages 30
Rectangular
Dimensions " (mm) 0.47 x 1.3 x 0.78 (12 x 34 x 20) 0.7 x 1.9 x 1.9 (18 x 50 x 50) 1.2 x 4.5 x 3.4 (30 x 114 x 87.5)
520220
501542_1
805167
Applications Packaging, Counting access Control, Conveyor
Range in Meters
with emitter accessory 18 35 60
with reflector accessory 4 5.7 15
diffuse without accessory0.02 0.55 1.2 3
Diffuse w/bgs without accessory 0.10 0.3 1.3
Body style XUM XUK XUX
Pages 46 50 54
A complete offer structured to the specific needs of the market today.
• Multi-Mode Detectors - Products for multiple functions.
• General Detectors - Product with essential functions for minimum cost.
• Application Specific - Products designed to perform the most difficult applications to the end users requirements.
29
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode Front Sensing, DC
18 mm Plastic Tubular / Multi-Mode Front Sensing, DC
Features:
• Ability to select sensing mode (Diffuse, Diffuse w/Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0•••••NL2
• Housing: Plastic
Photoelectric Sensors
Accessories
thread Description Connection Type Catalog Number
M18x1 Reflector – XUZC50
2m (6.6’) cable XUB0AKSNL2T
Transmitter
4 pin micro connector XUB0AKSNM12
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix.
Dimensions
inches (mm)
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
30
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode Front Sensing, DC
18 mm Plastic Tubular / Multi-Mode Front Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Sensing Distance (Sn) Diffuse Standard 30 cm
4 Output (excess gain = 2)
1 2
Polarized Retroreflective 2m
2 Test
Thru-Beam 15 m
Cable
Photoelectric Sensors
PNP Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
(-) Blue
BN/1 + Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X (indoor), 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67 Double Insulated
Beam Break Test Violet
Case PBT
NPN Emitter
Enclosure Material Lens PMMA
BN/1 + 1/BN Cable PVR
NPN
BK/4 2/VI
3/BU Mounting nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
BU/3 – Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA (20mA – XUB0…T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799
Agency Listings
®
Accessories
Description Catalog Number
Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
XUZC50 XUZB2003 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
6
15
Ø 12 mm 4
2
40
10 15 20 m -2 0,2 4 m
0,8
-15 3
-4
-6
3
31
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Plastic Tubular / Multi-Mode 90 Degree Side Sensing, DC
Features:
550001
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0••••WL2 • Housing: Plastic
Photoelectric Sensors
• Light(N.C.)/Dark(N.O.) selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Type Range Type d Maximum Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0APSWL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0APSWM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0ANSWL2
N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0ANSWM12
Accessories
XUB0•••••WM12
Description Connection Type Catalog Number
thread Reflector – XUZC50
M18x1 2 m (6.6’) cable XUB0AKSWL2T
Transmitter
4 pin micro conn XUB0AKSWM12
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix.
Dimensions
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
32
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Plastic Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Plastic Tubular / Multi-Mode 90 Degree Side Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Diffuse Standard 20 cm
Sensing Distance (Sn)
4 Output
(excess gain - 2_ Polarized Retroreflective 1.5 m
1 2 2 Test
Thru-Beam 10 m
Cable PNP
Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue PNP BK/4
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(+) Brown NEMA Type 4X (indoor), 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67 Double Insulated
Beam Break Test Violet
Case PBT
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 5 N•m (44.4 lb-in)
BU/3 – Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35mA (20mA – XUB0…T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799
Agency Listings
®
Accessories
Description Catalog Number
Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
XUZB2003
XUZC50 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
6
15
Ø 12 mm 4
2
10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3
33
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode Front Sensing, DC
18 mm Metal Tubular / Multi-Mode Front Sensing, DC
Features:
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0•••••ML2
• Housing: Metal
Photoelectric Sensors
b
a Variation of Usable Sensing Distance
Diffuse System with Adjustable Background Suppression
Cable Connector
Learning at Minimum Learning at Maximum
a b a b
B B
∅ 18
Front 2.5 (64) 1.7 (44) 3.1 (78) 1.7 (44) A-B: Object Reflection Coefficient
Sensing Black 6%
Gray 18%
White 90%
Dimension “a” for XUB0...T is 2.4 (62) / 3.0 (76).
Sensing Range
Non-sensing Zone (matt surfaces)
inches (mm) A 0,01 0,07 0,1 A 0,01
S (m) 0,11 0,15 S (m)
0,08 0,12
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
34
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode Front Sensing, DC
18 mm Metal Tubular / Multi-Mode Front Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse w/ Background Supp. 12 cm
1 (+) Standard Diffuse 30 cm
Sensing Distance (Sn)
4 Output
(excess gain = 2) Pol. Retroreflective 2m
1 2 2 Test
Thru-Beam 15 m
Cable PNP
Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X, 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67
Beam Break Test Violet
Case Nickel Plated Brass
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 15 N•m (133.3 lb-in)
– Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal instability Red
Power & teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA (20 mA – XUB0….T)
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799
Agency Listings
®
Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
90 ° metal mounting bracket XUZA118
XUZB2003
XUZC50 Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
6
15
Ø 12 mm 4
2
10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3
35
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Metal Tubular / Multi-Mode 90 Degree Side Sensing, DC
Features:
550001
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
XUB0••••WL2 • Housing: Metal
Photoelectric Sensors
thread
M18x1
• N.C. / N.O. selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Type Range Type d Maximum Maximum
N.C. / N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BPSWL2
N.C. / N.O. PNP 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BPSWM12
N.C. / N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUB0BNSWL2
N.C. / N.O. NPN 12-24 Vdc 4 pin micro conn 100 mA 250 Hz XUB0BNSWM12
Accessories
XUB0•••••WM12 Description Connection Type Catalog Number
Reflector – XUZC50
2 m (6.6’) cable XUB0BKSWL2T
Transmitter
4 pin micro connector XUB0BKSWM12
b
Variation of Usable Sensing Distance
a
Diffuse System with Adjustable Background Suppression
Cable Connector Learning at Minimum Learning at Maximum
a b a b B B
∅ 18 A-B: Object Reflection Coefficient
90° Side 3.1 (78) 1.7 (44) 3.6 (92) 1.7 (44) Black 6%
Sensing Gray 18%
White 90%
inches (mm)
Sensing Range
Non-sensing Zone (matt surfaces)
A 0,01 0,07 0,1 A 0,01 0,11 0,15 S (m)
S (m)
0,08 0,12
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
36
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
18 mm Metal Tubular
Multi-Mode 90 Degree Side Sensing, DC
18 mm Metal Tubular / Multi-Mode 90 Degree Side Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 3 (-) Diffuse Background Supp. 12 cm
1 (+) Standard Diffuse 20 cm
Sensing Distance (Sn)
4 Output
(excess gain = 2) Pol. Retroreflective 1.5 m
1 2 2 Test
Thru-Beam 10 m
Cable PNP
Photoelectric Sensors
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
BN/1 + Temperature Range
(-) Blue Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
PNP BK/4
(+) Brown NEMA Type 4X, 12
(Output) Black Enclosure Rating
BU/3 – IEC Type IP67
Beam Break Test Violet
Case Nickel Plated Brass
NPN Emitter
Enclosure Material Lens PMMA
BN/1 +
NPN 1/BN Cable PVR
BK/4 2/VI
3/BU Mounting nuts 15 N•m (133.3 lb-in)
– Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
Output Yellow
LED indicator Signal Instability Red
Power & Teach Green
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35mA
Load Current maximum 100 mA
Maximum Operating Frequency 250 Hz
On Delay Maximum 2 ms
Off Delay Maximum 2 ms
Power up Delay Maximum 200 ms
Short Circuit Protection Yes
XUZA118 XUZA218
Overload Protection Yes
Reverse Polarity Protection Yes
805799
Agency Listings
®
Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
90 ° metal mounting bracket XUZA118
XUZC50 XUZB2003
Plastic clamp style mounting bracket XUZA218
3-D mounting bracket (stem not included) XUZB2003
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
See page 94 for complete 3-D assembly.
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
6
15
Ø 12 mm 4
2
10 15 20 m 40
-2 0,2 4 m
0,8
-15 3
-4
-6
3
37
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Plastic Tubular
Front Sensing, DC
18 mm Plastic Tubular / Front Sensing, DC
thread Features:
M18x1
• Housing: Plastic
• Mounting Nuts included
• UL Listed, CSA Certified
XUB•A•••••WL2 • CE Marked
Photoelectric Sensors
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
38
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Plastic Tubular
Front Sensing, DC
18 mm Plastic Tubular / Front Sensing, DC
Specifications
Wiring
Mechanical
Connector For usable sensing range, see detection curves
4 3 3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
1 (+) Temperature Range
4 Output Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2
2 Test NEMA Type 4X (indoor), 12
Enclosure Rating
Cable IEC Type IP67 Double Insulated
PNP
Photoelectric Sensors
Case PBT
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Enclosure Material Lens PMMA
(+) Brown
(Output) Black – Cable PVR
BU/3
Beam Break Test Violet Mounting nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
NPN Connector 2 N•m (17.7 lb-in)
BN/1 + Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
NPN
BK/4 (NO/NC) Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
BU/3 – LED indicator Output Yellow
Cable 4.2 mm O.D. 3 conductor 0.34 mm2
Emitter Connection
Connector 4 pin Micro style DC (M12)
1/BN
2/VI Electrical
3/BU
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
E
Agency Listings
®
XUZA118 XUZA218
Accessories
805799
Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity
6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m
Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50
39
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Plastic Tubular
90 Degree Side Sensing, DC
18 mm Plastic Tubular / 90 Degree Side Sensing, DC
Features:
550001
• Housing: Plastic
• Mounting Nuts included
• UL Listed, CSA Certified
• CE Marked
XUB•A••••WL2
Photoelectric Sensors
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
40
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Plastic Tubular
90 Degree Side Sensing, DC
18 mm Plastic Tubular / 90 Degree Side Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 3 (-) Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X (indoor), 12
1 2 Enclosure Rating
2 Test IEC Type IP67 Double Insulated
Case PBT
Photoelectric Sensors
Cable PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 + Cable PVR
PNP BK/4 (NO/NC)
(+) Brown
Mounting nuts 5 N•m (44.4 lb-in)
(Output) Black – Maximum Tightening Torque
BU/3 Connector 2 N•m (17.7 lb-in)
Beam Break Test Violet
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
NPN Emitter
Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
BN/1 + 1/BN LED indicator Output Yellow
NPN
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor 0.34 mm2
– Connection
BU/3 Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
Agency Listings
®
Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799
XUZC50
XUZB2003
Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity
6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m
Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50
41
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Metal Tubular
Front Sensing, DC
18 mm Metal Tubular / Front Sensing, DC
thread
Features:
M18x1 • Housing: Metal
• Mounting Nuts included
• UL Listed, CSA Certified
XUB•B•••••L2
• CE Marked
Photoelectric Sensors
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
42
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Metal Tubular
Front Sensing, DC
18 mm Metal Tubular / Front Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 3 (-) Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X, 12
1 2
2 Test Enclosure Rating
IEC Type IP67 Double Insulated
Cable Case Nickel Plated Brass
Photoelectric Sensors
PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Cable PVR
(+) Brown
(Output) Black Mounting nuts 15 N•m (133.3 lb-in)
BU/3 – Maximum Tightening Torque
Beam Break Test Violet Connector 2 N•m (17.7 lb-in)
NPN Emitter Vibration Resistance (IEC 60068-2-6) 7 gn, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BN/1 + 1/BN
NPN LED indicator Output Yellow
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor 0.34 mm2
BU/3 – Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
Agency Listings
®
Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799
XUZC50
XUZB2003
Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity
6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m
Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50
43
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Metal Tubular
90 Degree Side Sensing, DC
18 mm Metal Tubular / 90 Degree Side Sensing, DC
Features:
550001
• Housing: Metal
• Mounting Nuts included
• UL Listed, CSA Certified
• CE Marked
XUB•B••••WL2
Photoelectric Sensors
a b a b
Polarized Retroreflective – 2 m (6.6’) Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPAWL2
∅ 18
90 ° Side 2.4 (62) 1.1 (28) 3.0 (76) 1.1 (28) N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BPBWL2
Sensing N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNAWL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB9BNBWL2
18 mm
3.0 (78) 1.7 (44) 3.6 (92) 1.7 (44)
XUB5 N.O. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPAWM12
N.C. PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BPBWM12
inches (mm)
N.O. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNAWM12
N.C. NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB9BNBWM12
Fixed Proximity Diffuse – 10 cm (4") Nominal Sensing Distance
N.O.) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPAWL2
N.C) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BPBWL2
N.O.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNAWL2
N.C.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB4BNBWL2
N.O.) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPAWM12
N.C) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BPBWM12
N.O.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNAWM12
N.C.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB4BNBWM12
Adjustable Proximity Diffuse – 60 cm (23.6") Nominal sensing Distance
N.O.) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPAWL2
N.C) PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BPBWL2
N.O.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNAWL2
N.C.) NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 500 Hz XUB5BNBWL2
N.O.) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPAWM12
N.C) PNP 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BPBWM12
N.O.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNAWM12
N.C.) NPN 12-24 Vdc 4 pin Micro conn 100 mA 500 Hz XUB5BNBWM12
a 5 m cable length available with L5 suffix.
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
44
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Metal Tubular
90 Degree Side Sensing, DC
18 mm Metal Tubular / 90 Degree Side Sensing, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
4 3 Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
4 Output NEMA Type 4X, 12
1 2
2 Test Enclosure Rating
IEC Type IP67 Double Insulated
Cable Case Nickel Plated Brass
Photoelectric Sensors
PNP
Enclosure Material Lens PMMA
(-) Blue BN/1 +
PNP BK/4 (NO/NC) Cable PVR
(+) Brown
(Output) Black Mounting nuts 15 N•m (133.3 lb-in)
BU/3 – Maximum Tightening Torque
Beam Break Test Violet Connector 2 N•m (17.7 lb-in)
NPN Emitter Vibration Resistance (IEC 60068-2-6) 7 gn, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BN/1 + 1/BN
NPN LED indicator Output Yellow
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor
BU/3 – Connection
Connector 4 pin Micro style DC (M12)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
Agency Listings
®
Accessories
Description Catalog Number
XUZA118 XUZA218 Reflector 50x50mm XUZC50
90 ° metal mounting bracket XUZA118
805799
XUZC50 XUZB2003
Detection Curves
Diffuse System
Thru-beam System Diffuse System Retroreflective System Polarized Retroreflective System
with Adjustable Sensitivity
6
15 10
Ø 12 mm 4
4 2
0,15
10 15 m 0,8 0,05
cm 4 m 2 3 m
-15 -4 2 -2 0,2
0,08 -4
-10
-6
Sn ≤ 2 m
Object: 3.9 x 3.9" (10 x 10 cm); / 1: White 90%, 2: Grey 18% With Reflector XUZC50
45
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUM Miniature Rectangular
Multi-Mode, DC
XUM Miniature Rectangular / Multi-Mode, DC
Features:
501542_1
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors
XUM OA••L2
• N.C. / N.O. selectable
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
501543_1
Accessories
XUM OA••M8 Description Connection Type Catalog Number
Reflector – XUZC50
2 m (6.6’) cable XUM0AKSAL2T
Transmitter
M8 Nano connector XUM0AKSAM8T
a Transmitter required for multi-mode receiver to operate in Thru-beam mode
Dimensions c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
d 5 m cable length available with L5 suffix / 10 m cable length available with L10 suffix.
XUM
Ø3
Variation of Usable Sensing Distance
Diffuse System with Adjustable Background Suppression
25.5
1.3
1.0
34
B B
0.47
A-B: Object Reflection Coefficient
12
0.78 Black 6%
20 Gray 18%
White 90%
Sensing Range
Ø3 A 0,01 0,05 0,08 Non-sensing Zone (matt surfaces) A 0,01
S (m) 0,08 0,15 S (m)
0,06 0,10
1.3
1.7 34
25.5
1.0
45
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
0.78 0.47 modes.
20 12
46
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUM Miniature Rectangular
Multi-Mode, DC
XUM Miniature Rectangular / Multi-Mode, DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector Diffuse Background Supp. 10 cm
2 4 3 (-)
Sensing Distance (Sn) Diffuse Standard 40 cm
1 (+)
1 3 4 Output (excess gain = 2) Pol. Retroreflective 3m
2 Alarm or Test Thru-Beam 14 m
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Photoelectric Sensors
Cable Temperature Range
PNP Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(-) Blue BN/1 + NEMA Type 1, 3, 4, 6, 6P (cable version only), 12, 13
(+) Brown PNP Enclosure Rating
BK/4 WH/2 IEC Type IP67
(Output) Black
Alarm White – Case PBT
BU/3
Beam Break Test Violet Enclosure Material Lens PMMA
Cable PVR
NPN Emitter
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
BN/1 +
NPN 1/BN Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
BK/4 WH/2 2/VI
3/BU Output Yellow
BU/3 –
LED indicator Power & Teach Green
520313
Accessories
550015
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
10 2 6
Ø 10 mm 4
1 0,30 2
10 14 m 0,55 m 3 4 m
-1 -2 0,2
0,1
-10 -2 -4
-6 Sn 3m
Sn 10 m Sn 0,4 m
47
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature Rectangular
DC
XUM Miniature Rectangular / DC
Optimum miniature rectangular photoelectric sensors designed for OEMs & industrial applications.
550023
Features:
• Small dimensions, designed to fit in those tight applications
• Quick connect versions
• Available in either N.C. or N.O. operation
XUM •A••L2
Photoelectric Sensors
27 12
N.C. PNP 12-24 Vdc M 8 Nano conn. 100 mA 500 Hz XUM1APBNM8
4
5 1.0 8
48
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature Rectangular
DC
XUM Miniature Rectangular / DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
3 (-) Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
2 4 Temperature Range
1 (+) Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 3 4 Output
NEMA Type 1, 3, 4, 4X (indoor), 6, 6P (cable version only), 12, 13
2 Test Enclosure Rating
IEC Type IP67
Cable PNP
Photoelectric Sensors
Case PBT
(-) Blue
BN/1 + Enclosure Material Lens PMMA
PNP BK/4 (NO/NC)
(+) Brown Cable PVR
(Output) Black –
BU/3 Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Beam Break Test Violet
Shock Resistance (IEC 60067-2-27) 30 g duration 11 ms
NPN Emitter
Output Yellow
BN/1 + LED indicator
NPN 1/BN Power Green (XUM2…T)
BK/4 (NO/NC) 2/VI
3/BU Cable 4.2 mm O.D. 3 conductor
BU/3 – Connection
Connector 4 pin Nano style DC (M8)
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (including ripple) 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V
Current Consumption (no load) maximum 35 mA
Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz (400 Hz Thru-Beam)
On Delay Maximum 1 ms
Off Delay Maximum 1 ms
Power up Delay Maximum 30 ms
Polarized - red 660 nm
Wavelength Short Range Proximity 660 nm
All others 880 nm
Overload Protection Yes
Protective Circuitry
Short Circuit Protection Yes
Agency Listings
®
Accessories
Description Sensing Distance Catalog Number
90 ° mounting bracket (cable version) – XUZA47
90 ° mounting bracket (connector version) – XUZA46
0.5 mm diameter 4.5 cm (1.78") XUMZ01
Thru-beam aperture 1.0 mm diameter 4.5 cm (1.78") XUMZ02
XUMZ0k 2.0 mm diameter 4.5 cm (1.78") XUMZ03
Thru-Beam Aperture
Detection Curves
Thru-Beam System Diffuse Diffuse Polarized Retroreflective Retroreflective
Long Range Short Range
8 1
2 1 6 6
Ø 6 mm 2 2 2 4 4
1 1 2 2
0,1
8 m m
-2 0,2 2 -2 0,2
0,6 m 0,15 m 4
-1 -1 -4 -4
-8 0,1 0,2 0,025 -6 -6
-2 -2 Sn 2m Sn 4m
Sn 8m
Sn 0,4 m Sn 0,1 m
Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 % With Reflector XUZ C50 With Reflector XUZ C50
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
49
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUK Subcompact Rectangular
Multi-Mode, DC and AC/DC
XUK Subcompact Rectangular / Multi-Mode, DC and AC/DC
Features:
805167
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Pol.
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors
XUK 0AKSAL2
• N.C. / N.O. selectable
805166
Operating
Circuit Voltage Connection Load Current
Output Mode Frequency Catalog Number
Type Range Type d Maximum
Maximum
N.C. / N.O. PNP/NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK0AKSAL2
N.C. / N.O. PNP/NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK0AKSAM12
N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK0ARCTL2
50
0.78
0.7
18 B
A-B: Object Reflection Coefficient B
Black 6%
Gray 18%
Dual Dimensions inches White 90%
mm
Sensing Range
A 0,01 0,05 0,08
S (m)
Non-sensing Zone (matt surfaces) A 0,02 0,26 0,38 S (m)
0,06 0,3
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
50
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUK Subcompact Rectangular
Multi-Mode, DC and AC/DC
XUK Subcompact Rectangular / Multi-Mode, DC and AC/DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector
Diffuse Background Supp. 30 cm
3 (-)
4 3
1 (+) Sensing Distance (Sn) Diffuse Standard 1m
4 Output (excess gain = 2) Pol. Retroreflective 4m
1 2
2 Alarm or Test Thru-Beam 30 m
Cable Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Photoelectric Sensors
PNP Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
(-) Blue BN/1 + NEMA Type 4, 4X (indoor), 12, 13
(+) Brown PNP
BK/4 WH/2 Enclosure Rating
(Output) Black IEC Type IP65
Alarm White BU/3 – Case PBT
Beam Break Test Violet Enclosure Material Lens PMMA
NPN Emitter Cable PVR
BN/1 + Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
NPN 1/BN
BK/4 WH/2 2/VI Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
3/BU Output Yellow
BU/3 –
LED indicator Signal Instability Red
Cable Power & Teach Green
Common White Cable 4.2 mm O.D. 4, 5 conductor
Blue N.O. Black Connection
Brown N.C. Gray Connector (DC version) 4 pin Micro style DC (M12)
Electrical AC/DC DC
Emitter
Voltage Range 24-240 Vac/dc 12 – 24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 2V 2V
Current Consumption (no load) maximum 3W 10 mA
Load Current maximum 3A 100 mA
Maximum Operating Frequency 30 Hz 250 Hz
On Delay Maximum 25 ms 20 ms
550028
550029
Agency Listings
XUZK2003 XUZK2004 ®
Accessories
550030
Detection Curves
Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
with Background Suppression Accessory
1
2
20 28
0,4 1,2 5,7
4
20 0,8m 4
51
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact Rectangular
DC and AC/DC
XUK Subcompact Rectangular / DC and AC/DC
Features:
805167
50
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1APANM12
0.8
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK1ANBNM12
Retroreflective 7 m (22’) Nominal Sensing Distance (reflectors sold separately)
Dual Dimensions inches N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK1ARCNL2
mm
Polarized Retroreflective 5 m (16’) Nominal Sensing Distance (reflectors sold separately)
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK9ANBNL2
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9APANM12
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK9ANBNM12
Polarized Retroreflective 4 m (13’) Nominal Sensing Distance (reflectors sold separately)
N.C. / N.O. AC/DC relay 20-240 Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK9ARCNL2
Proximity Diffuse 1 m (3.3’) Nominal Sensing Distance
N.O. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5APANL2
N.C. PNP 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5APBNL2
N.O. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5ANANL2
N.C. NPN 12-24 Vdc 2 m (6.6’) cable 100 mA 250 Hz XUK5ANBNL2
N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5APANM12
N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5APBNM12
N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUK5ANBNM12
Proximity Diffuse 1 m (3.3’) Nominal Sensing Distance
N.C. / N.O. AC/DC relay 20-340Vac/dc 2 m (6.6’) cable 3A 20 Hz XUK5ARCNL2
a 10 m cable length available with L10 suffix
Excess Gain
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
modes.
52
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact Rectangular
DC and AC/DC
XUK Subcompact Rectangular / DC and AC/DC
Specifications
Wiring Mechanical
For usable sensing range, see detecton curves
Connector M12
4 3 Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2 NEMA Type 4, 4X (indoor), 12, 13
Enclosure Rating
IEC Type IP65
Cable PNP/NPN PNP
Photoelectric Sensors
Case PBT
BN/1 +
(-) Blue PNP BK/4 (NO/NC) Enclosure Material Lens PMMA
(+) Brown Cable PVR
(Output) Black BU/3 –
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
NPN Emitter Shock Resistance (IEC 60068-2-27) 30 g, duration 11 ms
BN/1 + Output Yellow
1/BN
NPN
BK/4 (NO/NC) 2/VI LED indicator Stability Red
3/BU
BU/3 – Power Green (XUK2…T)
Cable 4.2 mm O.D. 3 conductor
Cable Connection
Connector (DC version) 4 pin Micro style DC (M12)
Common White
Blue N.O. Black Electrical AC/DC DC
Brown N.C. Gray Voltage Range 20-240 Vac/dc 12 – 24 Vdc
Emitter Voltage Limit (including ripple) 20-264 Vac/dc 10 – 30 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V 1.5 V
Current Consumption (no load) maximum 2W 35 mA
Load Current maximum 3A 100 mA
Maximum Operating Frequency 20 Hz 250 Hz
On Delay Maximum 25 ms 2 ms
550028
550029
Accessories
550030
805799
Detection Curves
Thru-Beam System Polarized Retroreflective Retroreflective Systems Diffuse System
0,5 1,5
53
10/02 © 1997-2002 Schneider Electric All Rights Reserved
OSICONCEPT™ Photoelectric Sensors
XUX Compact Rectangular
Multi-Mode, DC and AC/DC
XUX Compact Rectangular / Multi-Mode, DC and AC/DC
520220
Features:
• Ability to select sensing mode (Diffuse, Diffuse with Background Suppression, Polarized
Retroreflective c, or Thru-Beam a)
• Simple push-button teach for sensor to learn application
• Ability to reduce stock with one multi-mode sensor
• Housing: Plastic
Photoelectric Sensors
Operating
Circuit Voltage Load Current
Output Mode Connection Type Frequency Catalog Number
Type Range Maximum
Maximum
N.C. / N.O. PNP/NPN 12-24 Vdc PG 16 cable gland 100 mA 250 Hz XUX0AKSAT16
N.C. / N.O. PNP/NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX0AKSAM12
N.C. / N.O. AC/DC relay 20-240 Vac/dc PG 16 cable gland 3A 25 Hz XUX0ARCTT16
Accessories
XUX 0AKSAM12 Description Connection Type Catalog Number
Reflector – XUZC50
12-240 Vdc 2 m (6.6’) cable XUX0AKSAT16T
Transmitter 12-240 Vdc 4 pin micro conn. XUX0AKSAM12T
24-240 Vac/dc 2 m (6.6’) cable XUX0ARCTT16T
Dimensions a Transmitter required for multi-mode receiver to operate in Thru-beam mode
c Reflector required for multi-mode receiver to operate in Polarized Retroreflective mode
PG 16 cable gland is for cable size from 0.27" to 0.40" (7 to 10 mm) diamter.
(1)
4.09 (104)
4.48 (114)
3.62 (92)
2.9
(3)
73
(2)
Excess Gain
1.18
M12
30
1.49
38
0.82 (21) An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing
1.96 1.20 (30.5)
50
modes.
2.8
71 3.0
77
Variation of Usable Sensing Distance
3.4
87 Diffuse System with Adjustable Background Suppression
Learning at Minimum Learning at Maximum
XUX•••••M12
B B
A-B: Object Reflection Coefficient
(1) Black 6%
4.09 (104)
3.62 (92)
Gray 18%
5.0 (127)
3.4
87
(3)
White 90%
Sensing Range
A 0,07 Non-sensing Zone (matt surfaces)
0,4 0,5 S (m) A 0,01 1,3 1,5 S (m)
(2) 1.18 0,42 1,35
0.86 (22)
30
1.49 1.18 (30)
38
1.96
50
2.8
71 3.0 XUZX2001 XUZX2002
3.44 77
1.2 1.2
87.5
31 31
0.43 0.43
11
XUX•••••T16 11
M16 x 1.5
M20 x 1.5
M16 x 1.5
1/2" NPT
inches (mm) /
54
©1997- 2002 Schneider Electric All Rights Reserved 10/02
OSICONCEPT™ Photoelectric Sensors
XUX Compact Rectangular
Multi-Mode, DC and AC/DC
XUX Compact Rectangular / Multi-Mode, DC and AC/DC
Specifications
Wiring Mechanical
For usable sensing range, see detection curves
Connector M12
4 3 Diffuse Background Supp. 1.3 m
Sensing Distance (Sn) Diffuse Standard 2m
1 2
(excess gain = 2) Pol. Retroreflective 11 m
Thru-beam 40 m
PNP/NPN Emitter
Photoelectric Sensors
M12 Terminal M12 Terminal Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
1 • 1 + 1 • 1 + Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
3 • 2 – 3 • 2 –
NEMA Type 4, 4X (indoor), 12, 13
4 • 3 2 • 3 Enclosure Rating
– • 4 — IEC Type IP67
– • 5 — Case PBT
Output Emitter Enclosure Material Lens PMMA
Terminal Terminal Cable PVR
1 1
Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
2 2
3 N.O. Shock Resistance (IEC 60068-2-27) 30 g, duration 11ms
4 Output Yellow
5 N.C.
LED indicator Signal Instability Red
Power & Teach Green
Cable Gland M16
Connection
Connector (DC version) 4 pin Micro style DC (M12)
Electrical AC/DC DC
Voltage Range 24-240 Vac/dc 12-24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10-36 Vdc
550041
Accessories
Description Catalog Number
Reflector 50x50 mm XUZC50
3-D mounting bracket (stem not included) XUZX2003
XUZC50 XUZX2001 3-D protective mounting bracket XUZX2004
M12 Stem (75 mm usable length) XUZ2001
3-D mounting base XUZ2003
Adapter ISO 16 to 1/2" NPT XUZX2001
Adapter ISO 16 to ISO 20 XUZX2002
See page 159 for complete 3-D assembly.
Detection Curves
80 Diffuse without Accessory Polarized Retroreflective with Reflector
Thru-beam with Thru-beam Accessory Diffuse without Accessory
40 with Background Suppression Accessory
20 Ø 8 mm
2 15
20 40 60 10
-20
1
-40
-80 11 15m
40 1 2 3 0,2
1,5
1
2,6
-10
2 -15
Sn < 2 Sn 11 m
55
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUX Compact Rectangular
DC and AC/DC
XUX Compact Rectangular / DC and AC/DC
Features:
• Interchangeable mounting of competitive compact sensor body styles.
• Available with terminal block wiring or connector version.
Operating
Voltage Connection Load Current
Output Mode Circuit Type Frequency Catalog Number
Range Type Maximum
Maximum
Photoelectric Sensors
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX1ANBNM12
4.44 (113)
3.62 (92)
2.9
(3)
73
N.C.N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX1ARCNT16
Polarized Retroreflective 11m (36‘) Nominal Sensing Distance (reflectors sold separately)
(2) 1.18 N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9APANT16
M12
30 N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9APBNT16
1.45 0.82 (21)
37 N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9ANANT16
1.96 1.20 (30.5)
50 N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX9ANBNT16
2.8
71 3.0 N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9APANM12
77 N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9APBNM12
3.4
87 N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9ANANM12
N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX9ANBNM12
XUX•••••M12 N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX9ARCNT16
Proximity Diffuse 2.1m (7.9‘) Nominal Sensing Distance
N.O. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5APANT16
(1)
4.09 (104)
3.62 (92)
N.C. PNP 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5APBNT16
5.0 (127)
3.4
87
(3)
N.O. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5ANANT16
N.C. NPN 12-24 Vdc PG16 cable entry 100 mA 250 Hz XUX5ANBNT16
(2) 1.18 N.O. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5APANM12
0.86 (22)
30
1.49 1.2 (30.5) N.C. PNP 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5APBNM12
38 N.O. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5ANANM12
1.96
50 N.C. NPN 12-24 Vdc 4 pin micro conn. 100 mA 250 Hz XUX5ANBNM12
2.8
71 3.0
N.C. / N.O. AC/DC relay 20-240 Vac/dc PG16 cable entry 3A 20 Hz XUX5ARCNT16
3.44 77 PG 16 cable gland is for cable size from 0.27" to 0.40" (7 to 10 mm) diamter.
87.5
XUX•••••T16
Excess Gain
inches (mm) /
An excess gain of 2 has been achieved at the nominal sensing distance (Sn) of all sensing modes.
Dual Dimensions inches
mm
XUZX2001 XUZX2002
1.2 1.2
31 31
0.43 0.43
11 11
M16 x 1.5
M20 x 1.5
M16 x 1.5
1/2" NPT
56
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUX Compact Rectangular
DC and AC/DC
XUX Compact Rectangular / DC and AC/DC
Wiring Specifications
Mechanical
Connector M12
For usable sensing range, see detection curves
4 3
Operating -13 ° to +131 ° F (-25 ° to +55 ° C)
Temperature Range
Storage -40 ° to +158 ° F (-40 ° to +70 ° C)
1 2
NEMA Type 1, 3, 4, 13
PNP/NPN Emitter Enclosure Rating
IEC Type IP67
M12 Terminal M12 Terminal
Photoelectric Sensors
1 • 1 + 1 • 1 + Case PBT
3 • 2 – 3 • 2 – Enclosure Material Lens PMMA
4 • 3 2 • 3
Cable PVR
– • 4 — – • 4 —
– • 5 — – • 5 — Vibration Resistance (IEC 60068-2-6) 7 g, amplitude +/- 1.5 mm (f=10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
Output Emitter
Terminal Terminal Output Yellow
1 1 LED indicator
Power Green
2 2
3 N.O. 3 — Cable gland M16
Connection
4 4 — Connector (DC version) 4 pin Micro style DC (M12)
5 N.C. 5 —
Electrical AC/DC DC
Voltage Range 20-240 Vac/dc 12-24 Vdc
Voltage Limit (including ripple) 20-264 Vac/dc 10-36 Vdc
Voltage Drop (across switch) closed state maximum 1.5 V 1.5 V
Current Consumption (no load) maximum 2W 35 mA
Load Current maximum 3A 100 mA
550041
Accessories
805799
Detection Curves
Thru-Beam System Diffuse System Polarized Retroreflective Retroreflective System
80 6 15 15
40 4 10 10
20 Ø 8 mm 2 5 5
20 40 60 0,7 2,10 3 10 15 m
-2 13 20 m
-20 -5 5 8
-4 -5
-40
-6 -10 -10
-80
40 Sn 2,1m -15 Sn 11 m -15 Sn 14 m
57
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Self-Teach XUD Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
Self-Teach XUD Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics
Features:
550026
XUDA1
• Self-teach capability
• Selectable light(N.C.)/dark(N.O.)
• Nano style connector available
Photoelectric Sensors
XUDA2
+
SET
ALM OUT M8 Nano connector
PNP N.C. / N.O. 12-24 Vdc 100 mA 1000Hz or 5000Hz XUDA2PSMM8
XUD A2 NPN N.C. / N.O. 12-24 Vdc 100 mA 1000Hz or 5000Hz XUDA2NSMM8
For XUFN and XUFS fiber optics see page 120 - 123.
OUT
- SET + H T S
58
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Self-Teach XUD Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
Self-Teach XUD Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics
Specifications
Wiring Mechanical
Temperature Range 13 ° F to 131 ° F (-10 ° C to 55 ° C)
XUDA1
No. Sensing Distance (Sn) Dependent on fiber optic (page 120)
Connector NEMA Type 1, 3, 4, 6, 12, 13
1 (+)
2 4 3 (-) Enclosure Rating
IEC Type IP65
4 Output
1 3
2 Vibration 7 g, amplitude +/-0.5 mm (f=10 to 55 Hz)
Photoelectric Sensors
Shock resistance 30 g, duration 11ms
Cable Output Yellow
LED Indicator
Signal Instability XUDA1 Red / XUDA2 Green
(+) Brown
(-) Blue Signal Level Display XUDA1– 7 LED segment / XUDA2 – 4 digit display
Output Black Cable version 4.2 mm O.D. 4 conductor
Connection
PNP NPN Connector version 4 pin M8 nano connector
BN/1 + BN/1 + Electrical
PNP NPN
BK/4 BK/4 Voltage Range 12-24 Vdc
BU/3 – BU/3 – Voltage Limit (including ripple) 10-30 Vdc
Maximum Load Current 100 mA
Current Consumption (no load) 50 mA
Alarm output current 50 mA (XUDA2)
Voltage Drop across Switch 1V
XUDA2
On Delay XUDA1 – 0.5 ms / XUDA2 – 0.1 ms
Connector
1 (+) Off Delay XUDA1 – 0.5 ms / XUDA2 – 0.1 ms
2 4 3 (-) Power up Delay 120 ms
4 Output
1 3
2 Alarm Short Circuit Protection Yes
Overload Protection Yes
Cable Reverse Polarity Protection Yes
Output Black
Alarm White
PNP NPN
BN/1 + BN/1 +
PNP NPN
BK/4 WH/2 BK/4 WH/2
BU/3 – BU/3 –
59
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUA 8 mm Diameter
Miniature Precision, DC
XUA 8 mm Diameter / Miniature Precision, DC
Features
• Ultra short miniature body
• Very fast response time
• Rugged metal case
• Short circuit, overload, and reverse polarity protection
Photoelectric Sensors
thread
• CE Mark
M8x1
Load Operating
Circuit Output Voltage
Current Frequency Catalog Number
Type Mode Range
Dimensions Max. Max.
Thru-beam (Emitter – Receiver) – 6.6' (2m) Nominal Sensing Range a
DC – 6' (2m) cable
.16
4 Emitter 2 wire – 12-24 V – – XUAH0203
Receiver 3 wire, PNP N.C. 12-24 V 100 mA 2000 Hz XUAH0224
Receiver 3 wire, PNP N.O. 12-24 V 100 mA 2000 Hz XUAH0214
1.18 Receiver 3 wire, NPN N.C. 12-24 V 100 mA 2000 Hz XUAJ0224
1.57 30
Receiver 3 wire, NPN N.O. 12-24 V 100 mA 2000 Hz XUAJ0214
40 M8x1
DC – Nano style connector (8 mm)➁
Emitter 2 wire – 12-24 V – – XUAH0203S
Receiver 3 wire, PNP N.C 12-24 V 100 mA 2000 Hz XUAH0224S
Receiver 3 wire, PNP N.O. 12-24 V 100 mA 2000 Hz XUAH0214S
Receiver 3 wire, NPN N.C 12-24 V 100 mA 2000 Hz XUAJ0224S
Receiver 3 wire, NPN N.O. 12-24 V 100 mA 2000 Hz XUAJ0214S
Proximity (Diffuse) – 1.9" (5cm) Nominal Sensing Range a ➀
LED
DC – 6' (2m) cable
.14 3 wire, PNP N.O. 12-24 V 100 mA 700 Hz XUAH0515
3.5
3 wire, PNP N.C. 12-24 V 100 mA 700 Hz XUAH0525
3 wire, NPN N.O. 12-24 V 100 mA 700 Hz XUAJ0515
3 wire, NPN N.C. 12-24 V 100 mA 700 Hz XUAJ0525
DC – Nano style connector (8 mm)➁
Nano Style Connector 3 wire, PNP N.O. 12-24 V 100 mA 700 Hz XUAH0515S
3 wire, PNP N.C. 12-24 V 100 mA 700 Hz XUAH0525S
13
60
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUA 8 mm Diameter
Miniature Precision, DC
XUA 8 mm Diameter / Miniature Precision, DC
Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Sensor side Temperature range -13° F to +131° F (-25° C to +55° C)
(OUT) NEMA Type 4, 6, 6P, 12, 13
thru-beam
4 (TEST) emitter only
Enclosure rating
CENELEC Type
IP67 conforming to IEC60529 (IP673 conforming to NF C 20-
010)
Mounting torque 1.47 ft-lb (2 N•m), Connector tighten torque
Tightening torque (max.)
0.14 ft-lb (0.3 N•m)
Photoelectric Sensors
(+) 1 3 (–)
Vibration 7 g, amplitude +/- .75 mm (f=10 to 55 Hz)
Shock resistance 30 g, duration 11 ms, conforming to IEC 60068-2-27
Case Nickel plated brass
Emitter Enclosure material
Lens PMMA
BN +
Wiring Cable: PVC, diameter 3.5 mm, wire AWG 26,3 x 0.14 mm2
BU - Electrical
VI Test Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch), closed state (max.) 1.8 V
PNP output
Maximum load current 100 mA
BN 1+
Current consumption (no load) (max.) Emitter: 20 mA; receiver: 20 mA; diffuse: 25 mA
BK 4
Maximum operating frequency Thru-beam: 2000 Hz, Proximity (Diffuse) 700 Hz
BU 3-
On delay (max.) Thru-beam: 0.25 ms Proximity (Diffuse): 0.75 ms
Off delay (max.) Thru-beam: 0.25 ms Proximity (Diffuse): 0.75 ms
NPN output Power-up delay (max.) 20 ms
BN 1+ Physical Characteristics
BK 4 Ambient light immunity 3000 Lux
BU 3- Thru-beam 890 nm
Emitter wave length:
Proximity (Diffuse) 940 nm
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
Fast transients (motor start/stop
IEC 61000-4-4, L3 (1 kV)
interference)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3 (2.5 kV)
E164869
Agency Listings CCN NRKH
®
XSZB108 831608
Accessories
Description Catalog Number
Universal mounting bracket (Plastic) XSZB108
Mounting bracket, diecast zinc 831608
Mounting bracket, plastic XSAZ108
Metal mounting nuts XSZE108
Sensing Pattern
Thru-beam System Diffuse System
61
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - Front Sensing, DC
thread
Features
M18x1 • Housing: Plastic
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
• Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,
Photoelectric Sensors
1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%
62
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - Front Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 4 Storage -40° to 158° F (-40° to 70° C)
Program- Output NEMA Type 4X (Indoor), 12
ming 3 (-)
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case PPS
Photoelectric Sensors
Light operate (no object present) Enclosure Material Lens PMMA
Retroreflective - PNP output Cable PvR
OG Mounting Nuts 5 N•m (44.4 lb-in)
Maximum Tightening Torque
BN Connector 2 N•m (17.7 lb-in)
BK Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2mm (f = 10 Hz to 55 Hz)
BU
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
Diffuse - PNP output
LED Indicator Type 360° ring LED: shows output status
OG
BN Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
Connector 4 pin Micro style DC (M12 male)
BK
BU Electrical
Retroreflective - NPN output Voltage Range 12 – 24 Vdc
OG
Voltage Limit (Including Ripple) 10 – 30 Vdc
BN
BK Voltage Drop (Across Switch) Closed State Maximum 1.5 V
BU Current Consumption (No Load) Maximum 30 mA Reflex and Diffuse, 50 mA Thru-Beam
Diffuse - NPN output Load Current Maximum 100 mA
OG
BN
Maximum Operating Frequency 500 Hz
BK On Delay Maximum 1 ms
BU Off Delay Maximum 1 ms
Dark operate (no object present) Power-up Delay Maximum 15 ms
Retroreflective - PNP output Short Circuit Protection Yes
BN
Overload Protection Yes
BK
BU Reverse Polarity Protection Yes
OG E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
Diffuse - PNP output ®
BN
BK Accessories
BU
Description Catalog Number
OG
Swivel Ball Mounting Bracket XUZA218
Retroreflective - NPN output
Plastic Mounting Bracket XSZB118
BN
Metal 90° Mounting Bracket 9006PA18
BK
Zinc Diecast 90° Mounting Bracket XUZA118
BU
OG Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318
Diffuse - NPN output
BN
BK
BU
OG
Detection Curves
m 4 m 1.5 2 m
10 15 -4 2 -2 0.2 10 cm
-15 -10 -4 -1
-6 -1.4
Sn 4 m Sn 1.5 m Sn 0.10 m
Sn 15 m
63
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - 90 Degree Side Sensing, DC
Features
thread
M18x1 • Housing: Plastic
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors
1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%
64
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Plastic Body / Classic Economy - 90 Degree Side Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam
emitter only All others Operation -13° to 131° F (-25° to 55° C)
1 (+) 1 (+)
Temperature Range
Storage -40° to 158° F (-40° to 70° C)
2 4 2 4 NEMA Type 4X (indoor), 12
Test Pro- Enclosure Rating
Output
3 (-) gramming 3 (-) CENELEC Type IP67 conforming to IEC 60529
Photoelectric Sensors
Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)
(-) BU (Blue)
(+) BN (Brown) Shock Resistance 30 gn for 11 ms conforming to 68-2-27
(OUT) BK (Black) LED Indicator Type 360° ring LED: shows output state
(Prog.) OG (Orange) Case PC/ABS
(Violet) Enclosure Material
(Test) VI Lens PMMA
For Thru-beam Emitter Only
Cable 4 wire, 4 x 0.34 mm2, PvR
Wiring
Light operate (no object present) Connector 4 pin Micro connector
Retroreflective
PNP output Electrical
OG
BN Voltage Range 12 – 24 Vdc
BK Voltage Limit (Including Ripple) 10 – 30 Vdc
BU Current Consumption (Maximum) (No Load) 30 mA Reflex and Diffuse, 50 mA Thru-Beam
NPN output Voltage Drop 1.5 V
OG
Power-up Delay (Maximum) 15 mA
BN
BK On Delay (Maximum) 1 ms
BU Off Delay (Maximum) 1 ms
Short Circuit Protection Yes
Diffuse Protective Circuitry
PNP output Overload Protection Yes
OG
BN E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
BK ®
BU
NPN output
OG
Detection Curves
BN
BK Thru-beam Retroreflective Polarized retroreflective Diffuse
BU
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
10 6 1.4
T/R
Dark operate (no object present) 15 4 1
O 12 mm T/R 4 T/R 2 2 1
Retroreflective E R
PNP output 4 m 1.5 2 m
10 15 m -4 2 -2 0.2 10 cm
BN -15 -10 -4 -1
-6 -1.4
BK Sn 4 m Sn 1.5 m Sn 0.10 m
Sn 15 m
BU
OG With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
NPN output 1 White 90%
2 Grey 18%
BN
BK
Beam break test (for thru-beam emitter only)
BU Beam made Beam broken
OG BN/1 BN/1
Diffuse
PNP output VI/2 VI/2
BN
BK BU/3 BU/3
BU
OG
NPN output
BN
BK
BU
OG
65
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - Front Sensing, DC
thread Features
M18x1
• Housing: Nickel plated brass
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors
1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%
66
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – Front Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - Front Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
2 4 Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
Program- Output
ming NEMA Type 4X (Indoor), 12
3 (-) Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Photoelectric Sensors
Enclosure Material Lens PMMA
Retroreflective - PNP output Cable PvR
OG Mounting Nuts 15 N•m (133.3 lb-in)
Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
BN
Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
BK
BU Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
LED Indicator Type 360° ring LED: shows output status
Diffuse - PNP output Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
OG Connection
Connector 4 pin Micro style DC (M12 male)
BN Electrical
BK Voltage Range 12 – 24 Vdc
BU Voltage Limit (Including Ripple) 10 – 30 Vdc
Retroreflective - NPN output Voltage Drop (Across Switch) Closed State Maximum 1.5 V
OG Current Consumption (No Load) Maximum 30 mA Reflex and Diffuse, 50 mA Thru-Beam
BN
Load Current Maximum 100 mA
BK
Maximum Operating Frequency 500 Hz
BU
On Delay Maximum 1 ms
Diffuse - NPN output Off Delay Maximum 1 ms
OG
Power-up Delay Maximum 15 ms
BN
Short Circuit Protection Yes
BK
Overload Protection Yes
BU
Reverse Polarity Protection Yes
Dark operate (no object present) E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
Retroreflective - PNP output ®
BN
Accessories
BK
Description Catalog Number
BU
Swivel Ball Mounting Bracket XUZA218
OG
Plastic Mounting Bracket XSZB118
Diffuse - PNP output Metal 90° Mounting Bracket 9006PA18
BN Zinc diecast 90° Mounting Bracket XUZA118
BK Plastic Mounting Nuts XSZE218
BU Stainless Steel Mounting Nuts XSZE318
OG
Detection Curves
Retroreflective - NPN output
Thru-beam Polarized Retroreflective Diffuse
BN Retroreflective
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
BK cm cm cm cm
10 6 1.4
BU T/R
15 4 1
O 12 mm T/R 4 T/R 2 2 1
E R
OG
m 4 m 1.5 2 m
10 15 -4 2 -2 0.2 10 cm
Diffuse - NPN output -15 -4 -1
-10
-6 -1.4
BN Sn 4 m
Sn 15 m Sn 1.5 m Sn 0.10 m
BK
BU With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
OG 1 White 90%
2 Gre
y 18%
67
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - 90 Degree Side Sensing, DC
thread
Features
M18x1
• Housing: Nickel plated brass
• Modulated LED output indication
• Short circuit (SCP) reverse polarity and overload protection
• Light/Dark selectable
Photoelectric Sensors
1 0.1 0.1 1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.2 0.5 1 4 5 10 0.1 0.5 1 1.5 3 5 0.1 0.2 0.5 1 2 5 10 20 60
D(m) D(m) D(m) D(cm)
With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
White 90%
68
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic Economy – 90 Degree Side Sensing, DC
18 mm Tubular, Metal Body / Classic Economy - 90 Degree Side Sensing, DC
Wiring Specifications
Mechanical
Connector For usable sensors range, see excess gain curve charts
1 (+)
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 4 Storage - 40° to 158° F (- 40° to 70° C)
Program- Output NEMA Type 4X (Indoor), 12
ming Enclosure Rating
3 (-) IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass
Enclosure Material Lens PMMA
Photoelectric Sensors
Light operate (no object present)
Cable PvR
Retroreflective - PNP output Max. Tightening torque
Mounting nuts 15 N•m (133.3 lb-in)
OG Connector 2 N•m (17.7 lb-in)
BN Vibration resistance (IEC600 68-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BK
LED indicator type 360° ring LED: shows output status
BU
Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
Connector 4 pin Micro style DC (M12 male)
Diffuse - PNP output
OG
Electrical
Voltage Range 12 – 24 Vdc
BN
Voltage Limit (including ripple) 10 – 30 Vdc
BK
Voltage Drop (across switch) closed state max. 1.5 V
BU Current Consumption (no load) Max. 30 mA Reflex and Diffuse, 50 mA Thru-Beam
Retroreflective - NPN output Load Current Max. 100 mA
OG Max. Operating frequency 500 Hz
BN On delay max. 1 ms
BK Off delay max 1 ms
BU Power-up delay max 15 ms
Short circuit protection Yes
Diffuse - NPN output Overload protection Yes
OG
Reverse polarity protection Yes
BN E 164869 LR 44087
BK Agency Listings CCN NRKH Class 3211 03
®
BU
Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective - PNP output Swivel ball mounting bracket XUZA218
BN Plastic mounting bracket XSZB118
BK Metal 90° Mounting bracket 9006PA18
BU Zinc diecast 90° Mounting bracket XUZA118
OG Plastic mounting nuts XSZE218
Stainless Steel mounting nuts XSZE318
Diffuse - PNP output
BN
Detection Curves
BK Retroreflective Polarized retroreflective Diffuse
BU
OG
Dia. of beam Dia. of beam Dia. of beam
cm cm cm
Retroreflective - NPN output
10 6 1.4
BN T/R
4 1
BK T/R 4 T/R 2 2 1
BU 4 m
-4 1.5 2 m 10 cm
OG 2 -2 0.2
-10 -4 -1
Diffuse - NPN output -6 -1.4
BN Sn 4 m Sn 1.5 m Sn 0.10 m
BK
BU With reflector XUZC50 With reflector XUZC50 Object 10 x 10 cm
OG
1 White 90%
2 Grey 18%
69
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic - Front Sensing, DC
thread Features
M18x1 • Housing: Plastic • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors
Applicatio
Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU5B18PP340D
1.34 Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU5B18NP340
34 2.16 Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU5B18NP340D
Availability
55 Short Range Proximity Diffuse - 10 cm (4") Nominal Sensing Rangea
2.68
Light/Dark PNP 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8B18PP340
68
Light/Dark PNP 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU8B18PP340D
XU●B18●P340D
Light/Dark NPN 12 to 24 V 2 M (6.6’) cable 100 mA 500 Hz XU8B18NP340
Light/Dark NPN 12 to 24 V 4 pin Micro connector 100 mA 500 Hz XU8B18NP340D
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables
1 1 1 1
0.1 0.2 0.5 1 2 3 6 15 0.1 0.25 0.5 1 2 34 5 10 0.1 0.5 1 2 5 10 20 60 0.2 0.5 1 5 40
0.1 2 15
0.3 0.8 5 10 20 0.7 D(m) 0.2 15 D(cm) 10 20 60
D(m)
D(cm)
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
1 Polarized reflex XU9B18XP340 White 90% White 90%
2 Reflex XU1B18XP340
70
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Classic – Front Sensing, DC
18 mm Tubular, Plastic Body / Classic - Front Sensing, DC
Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Emitter Thru-beam receiver Operating -13° to 131° F (-25° to 55° C)
reflex and diffuse Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
1 (+) 1 (+) NEMA Type 4X (Indoor), 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
2 4 2 4
Test
Case PC/ABS
Program- Output
ming Enclosure Material Lens PMMA
3 (-)
Photoelectric Sensors
3 (-) Cable PVC
Mounting nuts 4 N•m (44.4 lb-in)
Light operate (no object present) Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
Retroreflective Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
PNP output Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
OG LED indicator type 360° ring LED: shows output status
BN Cable 4 mm diameter cable, 4 x 0.22 mm2 c.s.a. (3x 0.22 mm2 for Thru-beam Emitter)
Connection
BK Connector 4 pin Micro style DC (M12 male)
BU Electrical
Voltage Range 12 – 24 Vdc
NPN output Voltage Limit (including ripple) 10 – 30 Vdc
OG Voltage Drop (across switch) closed state max. 1.5 V
BN Retroreflective 35 mA
Current Consumption (no load)
BK Proximity (diffuse) 35 mA
Max.
Thru-beam 50 mA
BU Load Current Max. 100 mA
Retroreflective 500 Hz
Diffuse Max. Operating frequency Proximity (diffuse) 500 Hz
Thru-beam 400 Hz
PNP output
OG On delay max. 1 ms
BN Retroreflective 1 ms
Off delay max Proximity (diffuse) 1 ms
t
Overload protection Yes
ns – Lim
OG
it
BN
Applicatio
E 164869 LR 44087
BK Agency Listings CCN NRKH Class 3211 03
®
BU
Availability
Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective
Swivel ball mounting bracket XUZA218
PNP output Plastic mounting bracket XSZB118
BN Metal 90° Mounting bracket 9006PA18
BK Zinc diecast 90° Mounting bracket XUZA118
Plastic mounting nuts XSZE218
BU
Stainless Steel mounting nuts XSZE318
OG
90° mirror adapter for side sensing (Thru-beam only) Decrease sensing distance by 20% (0.80) XUBZ02
NPN output
90° mirror adapter for side sensing (All other models) Decrease sensing distance by 20% (0.80) XUBZ01
BN
BK
Detection Curves
BU
Thru-beam Reflex Diffuse (Sn = 10 cm) Diffuse (Sn = 40 cm)
OG Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
Diffuse 6 T/R 1.4 T/R
15 4 1 1 2
O 12 mm 2 1 1
PNP output T R T/R 2
BN 10 15 m 0.2 2 3 4 m 10 cm
-2 40 cm
-15 -4 -1 -1
BK -6 -1.4
BU Sn 15 m Sn 2 m (1) Sn 0.10 m Sn 0.40 m
OG Sn 4 m (2)
NPN output
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
BN (1) Polarized reflex XU9B18XP340 1 White 90% 1 White 90%
BK (2) Reflex XU1B18XP340 2 Grey 18% 2 Grey 18%
BU
OG
71
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, DC
18 mm Tubular, Metal Body / Classic - Front Sensing, DC
Features
thread
M18x1 • Housing: Metal • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors
1 0.1 0.1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10
A 0.01 0.1 1 10 40 100
0.11 0.15 S (m) D (m) D (m)
0.12 D (cm)
With reflector XUZC50 Object 10 x 10 cm
A-B : Object reflection coefficient White 90%
Black 6% Sensing range
Grey 18% Non sensing range
White 90% (Matt surfaces)
72
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, DC
18 mm Tubular, Metal Body / Classic - Front Sensing, DC
Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
Emitter Thru-beam receiver, Operating -13° to 131° F (-25° to 55° C)
reflex and diffuse Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
1 (+) 1 (+) NEMA Type 4X, 12
Enclosure Rating
2 4 2 4 IEC Type IP67 conforming to IEC 60529
Test Program- Case Nickel plated brass
Output
3 (-) ming 3 (-) Enclosure Material Lens PMMA
Photoelectric Sensors
Cable PvR
Light operate (no object present) Mounting nuts 5 N•m (44.4 lb-in)
Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
Retroreflective
Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2mm (f = 10 Hz to 55 Hz)
PNP output Shock resistance (IEC600 68-2-27) 30 gn, duration 11 ms
OG
LED indicator type 360° ring LED: shows output status
BN Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
Connection
BK Connector 4 pin Micro style DC (M12 male)
BU Electrical
Voltage Range 12 – 24 Vdc
NPN output Voltage Limit (including ripple) 10 – 30 Vdc
OG Voltage Drop (across switch)
1.5 V
BN closed state max.
BK Retroreflective 35 mA
Current Consumption (no load) Max. Proximity (diffuse) 35 mA
BU Thru-beam 50 mA
Load Current Max. 100 mA
Diffuse Max. Operating frequency 500 Hz
PNP output On delay max. 1 ms
OG Retroreflective 1 ms
BN Off delay max Proximity (diffuse) 1 ms
Thru-beam 1 ms
BK
Power-up delay max 15 ms
BU
Short circuit protection Yes
Overload protection Yes
NPN output
OG Reverse polarity protection Yes
BN E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
BK ®
BU Accessories
Dark operate (no object present)
Description Catalog Number
Retroreflective
Swivel ball mounting bracket XUZA218
PNP output Plastic mounting bracket XSZB118
BN Metal 90° Mounting bracket 9006PA18
Zinc diecast 90° Mounting bracket XUZA118
BK
Plastic mounting nuts XSZE218
BU
Stainless Steel mounting nuts XSZE318
OG 90° mirror adapter for side sensing (Thru-beam only)
NPN output XUBZ02
Decrease sensing distance by 20% (0.80)
BN 90° mirror adapter for side sensing (All other models)
XUBZ01
BK Decrease sensing distance by 20% (0.80)
BU Detection Curves
OG
Thru-beam Reflex Diffuse (Sn = 10 cm) Diffuse (Sn = 40 cm)
Diffuse Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
PNP output 6 T/R 1.4 T/R
15 4 1 1 2
T O 12 mm T/R 2 1 1
BN R 2
10 15 m 2 3 4 m
BK -2 0.2 10 cm 40 cm
-15 -4 -1 -1
BU -6 -1.4
OG Sn 15 m Sn 2 m (1) Sn 0.10 m Sn 0.40 m
NPN output Sn 4 m (2)
BN
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
BK (1) Polarized reflex XU9B18XP340 1 White 90% 1 White 90%
BU
(2) Reflex XU1B18XP340 2 Grey 18% 2 Grey 18%
OG
73
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, DC
Features
thread
M18x1 • Housing: Metal • Sensing modes: Thru-beam (emitter and receiver
• Modulated LED output indication packaged together), Retroreflective, Polarized
Retroreflective (XUZC50 reflector included in
• Short circuit (SCP) reverse polarity and
Retroreflective models), Proximity Diffuse,
overload protection
Proximity Diffuse with Background Suppression
• Light/Dark selectable
• Connector versions available
Photoelectric Sensors
.94
24
Variation of usable sensing distance Beam Break test (for thru-beam emitter only)
Diffuse system with adjustable Diffuse system with adjustable A-B : Object reflection Beam made BN/1 Beam broken
background suppression background suppression BN/1
coefficient
Potentiometer at minimum Potentiometer at maximum
Black 6% VI/2 VI/2
B B Grey 18%
Non sensing range
(Matt surfaces) BU/3 BU/3
White 90%
Sensing range
74
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, DC
Wiring Specifications
Mechanical
Connector
Thru-beam receiver, For usable sensing range, see excess gain curve charts
Emitter reflex and diffuse Operating -13° to 131° F (-25° to 55° C)
1 (+) 1 (+) Temperature Range
Storage -40° to 158° F (-40° to 70° C)
2 4 2 4 NEMA Type 4X (indoor), 12
Enclosure Rating
Test Program- Output IEC Type IP67 conforming to IEC 60529
3 (-) ming 3 (-) Case Nickel plated brass
Photoelectric Sensors
Enclosure Material Lens PMMA
Light operate Dark operate Cable PvR
(no object present) (no object present)
Mounting Nuts 5 N•m (44.4 lb-in)
Retroreflective Retroreflective Maximum Tightening Torque
Connector 2 N•m (17.7 lb-in)
PNP output OG PNP output Vibration Resistance (IEC600 68-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
BN
BN
BK Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
BK
BU
BU LED Indicator Type 360° ring LED: shows output status
OG
NPN output Cable 5 mm diameter cable, 4 x 0.34 mm2 c.s.a.
OG NPN output Connection
Connector 4 pin Micro style DC (M12 male)
BN BN
BK BK Electrical
BU BU
OG
Voltage Range 12 – 24 Vdc
Diffuse Diffuse Voltage Limit (Including Ripple) 10 – 30 Vdc
PNP output PNP output Voltage Drop (Across Switch) Closed State Maximum 1.5 V
OG
BN BN
Retroreflective 35 mA
BK Current Consumption (No Load)
BK Proximity (Diffuse) 35 mA
BU BU Maximum
OG
Thru-beam 50 mA
NPN output Load Current Maximum 100 mA
OG NPN output
BN BN Maximum Operating Frequency 500 Hz
BK BK
BU
On Delay Maximum 1 ms
BU
OG Retroreflective 1 ms
Off Delay Maximum Proximity (Diffuse) 1 ms
Thru-beam 1 ms
Power-up Delay Maximum 15 ms
Short Circuit Protection Yes
Overload Protection Yes
Reverse Polarity Protection Yes
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®
Accessories
Description Catalog Number
Swivel Ball Mounting Bracket XUZA218
Plastic Mounting Bracket XSZB118
Metal 90° Mounting Bracket 9006PA18
Zinc Diecast 90° Mounting Bracket XUZA118
Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318
Detection Curves
Thru-beam Polarized reflex Diffuse (Sn = 40 cm) Diffuse Background
suppression (Sn = 10 cm)
Dia. of beam Dia. of beam Dia. of beam Dia. of beam
cm cm cm cm
6 T/R T/R
15 4 1 1
T O 12 mm R T/R 1 1
2
2
10 15 m 1 2 m
-2 0.2 40 cm 12 cm
-15 -4 -1
-6 -1
Sn 15 m Sn 2 m Sn 0.10 m
Sn 0.40 m
With reflector XUZC50 Object 10 x 10 cm Object 20 x 20 cm
1 White 90% 1 White 90%
2 Grey 18% 2 Grey 18%
75
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - Front Sensing, AC/DC
Features
• Housing: Nickel plated brass
• Modulated LED output indication
thread
• Short circuit (SCP) reverse polarity and overload protection
M18x1 • Sensing modes: Thru-beam (emitter and receiver packaged together), Retroreflective,
.16 Potentiometer Polarized Retroreflective (XUZC50 reflector included in Retroreflective models), Proximity
Photoelectric Sensors
M18 x1
4 LED Diffuse, Proximity Diffuse with Background Suppression
• Also available in side sensing style
.16
• 2 meter cable standard
Dia.
2.16 5 • Connector versions available
55 3.15
• Wide selection of mounting brackets available
80
XU●M18●230 • Self locking mounting nuts included
.16 Potentiometer • UL Listed, CSA Certified
4 M18x1 LED
• CE Mark
Voltage Load Operating
Circuit Output Voltage Connection Catalog
Drop Current Frequency
Type Mode Range Type Number
Max. Max. Max.
2.16 Thru-Beam System (Emitter - Receiver) – 15 m (48') Nominal Sensing Distance a
55 3.15
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU2M18MA230
80 3.62 .94 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU2M18MA230K
92 24 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU2M18MB230
XU●M18●230K
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU2M18MB230K
Polarized Retroreflective – 2 m (6.6') Nominal Sensing Distance a (XUZC50 reflector included)
Variation of usable sensing
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MA230
distance 2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU9M18MA230K
Diffuse system with adjustable background 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU9M18MB230
suppression. Potentiometer at minimum. 2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU9M18MB230K
B Proximity Diffuse – 40 cm (15.7") Nominal Sensing Rangea
2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MA230
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU5M18MA230K
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU5M18MB230
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU5M18MB230K
Proximity Diffuse with Background Suppression – 12 cm (4.7") Nominal Sensing Distance
A 0.01 0.07 0.1 S (m) 2 wire Light 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MA230
0.08
2 wire Light 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU8M18MA230K
2 wire Dark 24-240 V 2 M (6.6’) cable 6V 200 mA 25 Hz XU8M18MB230
Diffuse system with adjustable background
2 wire Dark 24-240 V 3 pin Micro AC/DC connector c 6 V 200 mA 25 Hz XU8M18MB230K
suppression. Potentiometer at maximum.
B a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
c See p. 518 for matching connector cables
30
A-B : Object reflection cefficient 20 10
Black 6% Sensing range
Grey 18% Non sensing range 10 1
8
White 90% (Matt surfaces)
5
1
Marginal Detection 3
2
Thru-beam and reflex systems
1 0.1 0.1
Signal 1.5 1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10 0.1 1 10 40 100
level 1 D (m) D (m)
0.7 D (cm)
With reflector XUZC50 Object 10 x 10 cm
Red LED White 90%
Optimum
(alignment) Dual Dimensions inches
mm
LED off LED on
76
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – Front Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - Front Sensing, AC/DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam, reflex and diffuse Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 3
Storage - 40° to 158° F (- 40° to 70° C)
NEMA Type 4X, 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass
Enclosure Material Lens PMMA
Photoelectric Sensors
2 wire
Cable PvR
AC/DC Receiver
Mounting nuts 5 N•m (44.4 lb-in)
BN +/- Max. Tightening torque
Connector 2 N•m (17.7 lb-in)
BU +/- Vibration resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
2 wire LED indicator type 360° ring LED: shows output status
AC/DC Emitter ConnectionAC/DC Cable 5 mm diameter cable, 2 x 0.34 mm2 C.S.A.
AC/DC Connector 3 pin Micro style AC/DC (M12 male)
BN +/-
Electrical
BU +/- Voltage Range AC/DC Models 24 – 240 Vac/dc
Voltage Limit (including ripple) AC/DC Models 20 – 264 Vac/dc
Voltage Drop (across switch)
AC/DC Models 6V
closed state max.
Residual leakage Current
AC/DC Models 1.5 mA
(Open State)
20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization category DC-
Load Current AC/DC Models 10 – 200 mA 13
Vdc > 58 IEC 60947-5-2 Utilization category DC-12
Max. Operating frequency AC/DC Models 25 Hz
On delay max. AC/DC Models 20 ms
Retroreflective 20 ms
Off delay max Proximity (diffuse) 20 ms
Thru-beam 20 ms
Power-up delay max AC/DC Models 300 ms
Short circuit protection No
Overload protection No
Reverse polarity protection No
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®
Accessories
Description Catalog Number
Swivel ball mounting bracket XUZA218
Plastic mounting bracket XSZB118
Metal 90° mounting bracket 9006PA18
Zinc diecast 90° mounting bracket XUZA118
Plastic mounting nuts XSZE218
Stainless steel mounting nuts XSZE318
90° mirror adapter for side sensing (Thru-beam only)
XUBZ02
Decreases sensing distance by 20% (0.80)
90° mirror adapter for side sensing (All other models)
XUBZ01
Decreases sensing distance by 20% (0.80)
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, AC/DC
Detection Curves
Diffuse Background Suppression
Thru-Beam System Polarized Reflex Diffuse (Sn = 40 cm)
(Sn = 10 cm
6
1 1
15 4
2
1 2 3 m 0,3 60 cm 12 cm
10 15 20 m -2 0,2
-15 -4 -1 -1
-6
2
With reflector XUZ C50 Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 %
77
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, AC/DC
Features
thread
• Housing: Nickel plated brass • Sensing modes: Thru-beam (emitter and receiver
M18x1
• Modulated LED output indication packaged together), Polarized Retroreflective
(XUZC50 reflector included in Retroreflective
• Short circuit (SCP) reverse polarity and
models), Proximity Diffuse, Proximity Diffuse with
overload protection
Background Suppression
• 2 meter cable standard
• Also available in side sensing style
Photoelectric Sensors
30 Signal 1.5
level 1
20 10 0.7
10 1
8 Red LED
5 1 Optimum
3 (alignment)
2
LED off LED on
1 0.1 0.1
1 2 3 4 5 6 8 10 15 20 30 50 0.1 0.5 1 2 5 10 0.1 1 10 40 100
D (m) D (m) D (cm)
With reflector XUZC50 Object 10 x 10 cm White 90%
78
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Classic – 90 Degree Sensing, AC/DC
18 mm Tubular, Metal Body / Classic - 90 Degree Sensing, AC/DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Thru-beam, reflex and diffuse
Operating -13° to 131° F (-25° to 55° C)
Temperature Range
2 3 Storage - 40° to 158° F (- 40° to 70° C)
NEMA Type 4X (indoor), 12
Enclosure Rating
IEC Type IP67 conforming to IEC 60529
Case Nickel plated brass
Photoelectric Sensors
2 wire Enclosure Material Lens PMMA
AC/DC Receiver Cable PvR
BN +/- Mounting Nuts 5 N•m (44.4 lb-in)
Maximum Tightening torque
Connector 2 N•m (17.7 lb-in)
BU +/-
Vibration Resistance (IEC 60068-2-6) 25 gn, amplitude ± 2 mm (f = 10 Hz to 55 Hz)
Shock Resistance (IEC 60068-2-27) 30 gn, duration 11 ms
2 wire
AC/DC Emitter LED Indicator Type 360° ring LED: shows output status
Accessories
Description Catalog Number
Swivel Ball Mounting Bracket XUZA218
Plastic Mounting Bracket XSZB118
Metal 90° Mounting Bracket 9006PA18
Zinc Diecast 90° Mounting Bracket XUZA118
Plastic Mounting Nuts XSZE218
Stainless Steel Mounting Nuts XSZE318
See page 94 for complete assembly.
Detection Curves
Diffuse Background Suppression
Thru-Beam System Polarized Reflex Diffuse (Sn = 40 cm)
(Sn = 10 cm
6
1 1
15 4
2
1 2 3 m 0,3 60 cm 12 cm
10 15 20 m -2 0,2
-15 -4 -1 -1
-6
2
With reflector XUZ C50 Object : 3.9 x 3.9" (10 x 10 cm), 1 : White 90 %, 2 : Gray 18 %
79
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Stainless Steel Tubular
Front Sensing, DC
18 mm Stainless Steel Tubular Front Sensing, DC
Features
thread
M18x1 • Housing: Stainless Steel
• Food and Beverage Rated
• Mounting Nuts included
• UL Listed, CSA Certified
Photoelectric Sensors
• CE Marked
Load
Circuit Voltage Connection Operating
Output Mode Current Catalog Number
Type Range Type ♦ Frequency
Max.
Thru-Beam (emitter & receiver) – 15m (48’) Nominal Sensing Distance
Dimensions - Front Sensing Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18PP341
0.16 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18NP341
4 M18x1 (1)
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341D
Retroreflective – 4m (13’) Nominal Sensing Distance (reflector sold separately)
dia. 0.19 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18PP341
1.96 5 0.94
50 2.4 24 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18NP341
62 (2) Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18PP341D
XU•N18••341 Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18NP341D
Polarized Retroreflective – 2m (6.6’) Nominal Sensing Distance
0.16 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18PP341
4 M18x1 (1)
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18NP341
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18PP341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18NP341D
1.96 0.94 Proximity Diffuse – 10cm (4”) Nominal sensing Distance
50 2.4 24
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18PP341
62 2.8
72
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18NP341
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18PP341D
XU•N18••341D
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18NP341D
♦ 5m cable length available with L5 suffix
Dual Dimensions inches
mm
Excess Gain Curves
Thru-beam Retroreflective Polarized Retroreflective Diffuse
100 100 10
80
50
50
20 30
30
20
20 10 15
10 1 10
8 7
5 5
1
3
3
2 2
1 0,1 0,1 1
1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,5 1 1,5 3 5 0,1 0,2 0,5 1 2 5 10 20 60
0,1 0,2 0,5 1 45 10
D (m) D (m) D (cm)
D (m)
80
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Stainless Steel Tubular
Front Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature Range Operating -13 deg to +131 deg F (-25 deg to +55 deg C)
Storage -40 deg to +158 deg F (-40 deg to +70 deg C)
1 2
Enclosure Rating NEMA Type 4X (indoor), 12
1 (+) 1 (+) IEC Type IP67 Double Insulated
Enclosure Material Case Stainless Steel
Photoelectric Sensors
2 4 2 4
Test Program- Output Lens PMMA
3 (-)
ming 3 (-) Cable PVR
Maximum Tightening Torque Mounting nuts 15 Nm (133.3 lb-in)
Light operate (no object present) Connector 2 Nm (17.7 lb-in)
Vibration Resistance (IEC 68868-2-6) 7g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Retroreflective - PNP output
OG Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
BN LED indicator Output Yellow
Connection Cable 5mm O.D. 4 conductor 0.34mm2
BK
Connector 4 pin Micro style DC (M12)
BU
Electrical
Diffuse - PNP output Voltage Range 12 – 24 Vdc
OG Voltage Limit (including ripple) 10 – 30 Vdc
BN Voltage Drop (across switch) closed state maximum 1.5 V
BK Current Consumption (no load) maximum 30mA (reflex & diffuse), 50mA (thru-beam)
BU Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
Retroreflective - NPN output On Delay Maximum 1 ms
OG
Off Delay Maximum 1 ms
BN
Power up Delay Maximum 15 ms
BK
Short Circuit Protection Yes
BU Overload Protection Yes
Diffuse - NPN output Reverse Polarity Protection Yes
OG Agency Listings UL CSA CE
BN
BK
Accessories
BU Description Catalog Number
Reflector 50x50mm XUZC50
Dark operate (no object present) 90 degree metal mounting bracket XUZA118
Retroreflective - PNP output Plastic clamp mounting bracket XUZA218
BN 3-D mounting bracket (Stem nut included) XUZB2003
BK M12 stem XUZ2001
BU
Detection Curves
OG
Diffuse - PNP output Thru-beam Retroreflective Polarized Retroreflective Diffuse
BN 1,4
6
15 10 1
BK Ø 12 mm 4 2 1
4 2
BU
10 15 m 4 m 1,5 2 m 10 cm
OG -4 2 -2 0,2
-15 -4 -1
-10 -1,4
Retroreflective - NPN output -6
Sn ≤ 0,10 m
BN
BK Object: 3.9 x 3.9" (10 x 10 cm)
With Reflector XUZC50 With Reflector XUZC50
1: White 90%, 2: Grey 18%
BU
OG
Beam Break Test (For thru-beam emitter only)
Diffuse - NPN output
Beam Made Beam Broken
BN
BK BN/1 + BN/1 +
BU
OG VI/2 VI/2
BU/3 – BU/3 –
81
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Stainless Steel Tubular
90 Degree Sensing, DC
18 mm Stainless Steel Tubular 90 Degree Sensing, DC
Features
thread
M18x1 • Housing: Stainless Steel
• Food and Beverage Rated
• Mounting Nuts included
• UL Listed, CSA Certified
Photoelectric Sensors
• CE Marked
Load
Circuit Voltage Connection Operating
Output Mode Current Catalog Number
Type Range Type ♦ Frequency
Max.
Thru-Beam (emitter & receiver) – 15m (48’) Nominal Sensing Distance
Dimensions Side Sensing Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18PP341W
0.16
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU2N18NP341W
4 M18x1 (1) Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU2N18PP341WD
Retroreflective – 4m (13’) Nominal Sensing Distance (reflector sold separately)
dia. 0.19 Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18PP341W
1.96 5 0.94
50 3.07 24 Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU1N18NP341W
78 Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18PP341WD
XU•N18••341W Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU1N18NP341WD
Polarized Retroreflective – 2m (6.6’) Nominal Sensing Distance
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18PP341W
0.16
4 M18x1 (1) Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU9N18NP341W
Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU9N18NP341WD
Proximity Diffuse – 10cm (4”) Nominal sensing Distance
1.96 0.94
50 24
Light/Dark operate PNP 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18PP341W
2.4
62 2.8
Light/Dark operate NPN 12-24 Vdc 2m (6.6’) cable 100 mA 500 Hz XU5N18NP341W
88 Light/Dark operate PNP 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18PP341WD
Light/Dark operate NPN 12-24 Vdc 4pin Micro conn 100 mA 500 Hz XU5N18NP341WD
XU•N18••341WD
♦ 5m cable length available with L5 suffix
100 100 10
80
50
50
20 30
30
20
20 10 15
10 1 10
8 7
5 5
1
3
3
2 2
1 0,1 0,1 1
1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,5 1 1,5 3 5 0,1 0,2 0,5 1 2 5 10 20 60
0,1 0,2 0,5 1 45 10
D (m) D (m) D (cm)
D (m)
82
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Stainless Steel Tubular
90 Degree Sensing, DC
18 mm Stainless Steel Tubular 90 Degree Sensing, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature Range Operating -13 deg to +131 deg F (-25 deg to +55 deg C)
Storage -40 deg to +158 deg F (-40 deg to +70 deg C)
1 2
Enclosure Rating NEMA Type 4X (indoor), 12
1 (+) 1 (+) IEC Type IP67 Double Insulated
Enclosure Material Case Stainless Steel
Photoelectric Sensors
2 4 2 4
Test Program- Output Lens PMMA
3 (-)
ming 3 (-) Cable PVR
Maximum Tightening Torque Mounting nuts 15 Nm (133.3 lb-in)
Light operate (no object present) Connector 2 Nm (17.7 lb-in)
Vibration Resistance (IEC600 68-2-6) 7g, amplitude +/- 1.5mm (f=10 Hz to 55 Hz)
Retroreflective - PNP output
OG Shock Resistance (IEC 60068-2-27) 30g, duration 11ms
BN LED indicator Output Yellow
Connection Cable 5mm O.D. 4 conductor 0.34mm2
BK
Connector 4 pin Micro style DC (M12)
BU
Electrical
Diffuse - PNP output Voltage Range 12 – 24 Vdc
OG Voltage Limit (including ripple) 10 – 30 Vdc
BN Voltage Drop (across switch) closed state maximum 1.5 V
BK Current Consumption (no load) maximum 30mA (reflex & diffuse), 50mA (thru-beam)
BU Load Current maximum 100 mA
Maximum Operating Frequency 500 Hz
Retroreflective - NPN output On Delay Maximum 1 ms
OG
Off Delay Maximum 1 ms
BN
Power up Delay Maximum 15 ms
BK
Short Circuit Protection Yes
BU Overload Protection Yes
Diffuse - NPN output Reverse Polarity Protection Yes
OG Agency Listings UL CSA CE
BN
BK
Accessories
BU Description Catalog Number
Reflector 50x50mm XUZC50
Dark operate (no object present) 90 degree metal mounting bracket XUZA118
Retroreflective - PNP output Plastic clamp mounting bracket XUZA218
BN 3-D mounting bracket (Stem nut included) XUZB2003
BK M12 stem XUZ2001
BU
Detection Curves
OG
Diffuse - PNP output Thru-beam Retroreflective Polarized Retroreflective Diffuse
BN 1,4
6
15 10 1
BK Ø 12 mm 4 2 1
4 2
BU
10 15 m 4 m 1,5 2 m 10 cm
OG -4 2 -2 0,2
-15 -4 -1
-10 -1,4
Retroreflective - NPN output -6
Sn ≤ 0,10 m
BN
BK Object: 3.9 x 3.9" (10 x 10 cm)
With Reflector XUZC50 With Reflector XUZC50
1: White 90%, 2: Grey 18%
BU
OG
Diffuse - NPN output Beam Break Test (For thru-beam emitter only)
BN Beam Made Beam Broken
BK
BU BN/1 + BN/1 +
OG
VI/2 VI/2
BU/3 – BU/3 –
83
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
High Excess Gain, Thru Beam, DC
18 mm Tubular, Metal Body / High Excess Gain, Thru Beam, DC
Features
thread
M18x1 • Very high excess gain of 250,000 at 10 cm with strength to “burn through” polluted
environments such as in car washes or lumber milling applications
• Two distinct outputs: analog and digital with PNP output
• Analog can gauge density with sharp precision, as in hopper fill applications
• Digital output is ideal for detecting the presence of an object in nearly opaque packaging
Photoelectric Sensors
10 5
Dual Dimensions inches 8
mm
5
3
2
Beam Pattern 10 4
8
Dia. of beam 5
cm
3
2
15
Ø 12 mm
10 3
800
70 m
500
-15 300
200
Sn ≤50 m
100
80
50
30
20
10
8
5
3
2
1
0.1 0.2 0.3 0.5 1 2 3 5 10 20 30 50 100
D(m)
84
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
High Excess Gain, Thru Beam, DC
18 mm Tubular, Metal Body / High Excess Gain, Thru Beam, DC
Wiring Specifications
Mechanical
1 + For usable sensing range, see excess gain curve chart
2 Ie = 4 to 20 mA Operation -13° to 131° F (-25° to 55° C)
Temperature Range
mA Storage - 40° to 158° F (- 40° to 70° C)
Ie = 0 to 100 mA
4 NEMA Type 3, 4, 4X, 6, 12, 13
R
Enclosure Rating
3 R IEC Type IP67 conforming to IEC 60529
– Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)
R maxi < 800 Ω (Ue = 24 V), < 300 Ω (Ue = 12 V)
Photoelectric Sensors
Shock Resistance 30 G for 11 ms conforming to 68-2-27
Mounting Nuts 15 N•m (133 lb-in)
Tightening Torque
Connector 2 N•m (17.7 lb-in)
Beam Break Test (Emitter Only)
Repeatability (% of Sr) 3%
+ One green power LED c
LED Indicator Type
1 One yellow output LED c
2 Enclosure Material Nickel plated brass
Wiring 4 pin Micro connector
3 Electrical
– Voltage Limit (Including Ripple) 10 – 30 Vdc
Beam Made
Current Consumption (Maximum) (No Load) 55 mA (emitter and receiver)
+ Voltage Drop (Maximum) 1.5 V
1 Analog Output Range 4 to 20 mA
2 At -25° to 55° C 10%
Current Drift Due to Temperature
At 0° to 40° C 5%
3 Current Drift Due to Alignment 3%
– Power-up Delay (Maximum) 50 ms
Beam Broken
On Delay (Maximum) 15 ms
Off Delay (Maximum) 15 ms
Discrete (on/off) Output Green LED is illuminated c
Connector LED Operation
Analog Output Yellow LED is illuminated c
Emitter Receiver Short Circuit Protection Yes
1 (+) 1 (+) Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes
2 4 2 4 E 164869 LR 44087
Test Analog Solid State Agency Listings CCN NRKH Class 3211 03
®
Output Output
3 (–) 3 (–)
c See description of LED operation below.
0 to 99.5% 20
18
15
99.5 to 99.95%
10
5
99.95 to 100% 4
0
0 0.1 99.4 99.5 99.6 99.7 99.8 99.9 99.95 100% 0 1 0 1
Amount of Opaque
Example
Detection of number of sheets of white paper weighing 80 g (2.8 oz) with emitter and receiver at 10 cm apart.
Connector Cables (M12 or D suffix) Number of sheets 1 11 27 31
XSZCD101Y Micro Conn., 4 pin, 2 m, straight Analog output current (mA) 17,3 12 6 5
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . . Page 94, 157
85
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Analog Output, Proximity Diffuse, DC
18 mm Tubular, Metal Body / Analog Output, Proximity Diffuse, DC
Features
thread
M18x1 • 4 to 20 mA output, rather than discrete (on/off) output. As target characteristics change,
output adjusts accordingly
• Analog technology in popular 18 mm diameter body style
• Rugged metal enclosure with Micro style connector
• Potentiometer adjusts sensor’s sensitivity and reduces the color effects of the target
Photoelectric Sensors
Potentiometer at Maximum
.94 Is (mA)
24 25
20
Dual Dimensions inches
mm
15
2 1
10
5
4
1
0 10 20 30 40 50
D (cm)
Target Color
1 White 90%
2 Grey 15%
Potentiometer at Minimum
Is (mA)
25
20
2 1
15
10
5
4
1
0 10 20 30 40 50
D (cm)
Target Color
1 White 90%
2 Grey 15%
86
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Analog Output, Proximity Diffuse, DC
18 mm Tubular, Metal Body / Analog Output, Proximity Diffuse, DC
Wiring Specifications
Mechanical
Connector
Operation -13° to 131° F (-25° to 55° C)
1 (+) Temperature Range
Storage - 40° to 158° F (- 40° to 70° C)
Analog 2 4 NEMA Type 3, 4, 4X (Indoor), 6, 12, 13
Output Enclosure Rating
IEC Type IP67 per IEC 56029, IP671 per NFC 20-010
3 (–)
Vibration 7 G amplitude + 1.5 mm (f=10 to 55 Hz)
Photoelectric Sensors
1 + Shock Resistance 30 G for 11 ms conforming to 68-2-27
2 Mounting Nuts 15 N•m (133 lb-in)
Ie = Tightening Torque
R 4 to Connector 2 N•m (17.7 lb-in)
mA 20 mA
D Repeatability (% of Sr) 3%
3 –
LED Indicator Type One green LED showing output
Enclosure Material Nickel plated brass (window is PMAA)
Wiring 4 pin Micro connectorc
Electrical
Voltage Range 12 – 24 Vdc
Voltage Limit (Including Ripple) 10 – 30 Vdc
Current Consumption (Maximum) (No Load) 30 mA
Output Range 4 mA to 20 mA
At -25° to 55° C 10%
Maximum Output Current Drift
At 0° to 40° C 5%
Power-up Delay (Maximum) 50 ms
Light Emission Infrared
At 20 mA LED burns brightly (at maximum)
LED Intensity
At 4 mA LED burns dimly (at minimum)
Short Circuit Protection Yes
Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®
87
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Metal Body
Ultra Violet (UV), DC
18 mm Tubular, Metal Body / Ultra Violet (UV), DC
Features
thread
M18x1
• For detection of Ultra Violet marks and products containing UV blueing agents, as used for
packaging identification and quality assurance.
• Either Mark Reader or standard Diffuse sensing modes
• Sensitivity adjustment by 20 turn potentiometer
• 20 ms Off Delay built in timing feature
Photoelectric Sensors
• Popular 18 mm tubular body style in rugged metal enclosure with a 4 pin micro style
connection
Load Operating
Circuit Output Voltage Connection Catalog
Current Frequency
Type Mode Range Type Number
Max. Max.
.16 cm
4 3
M18x1 (1) (2)
2 8 cm
2.16 3
55 .94
3.23 24
82 Target 5 x 5 cm, white 90%
3.79
95 Spot size at 20 mm
Oval Dia. 3 x 1 mm
1.Potentiometer
2. Green LED Dual Dimensions inches
mm
88
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Metal Body
Ultra Violet (UV), DC
18 mm Tubular, Metal Body / Ultra Violet (UV), DC
Wiring Specifications
Mechanical
Connector
20 mm when reading UV mark
1 (+) Nominal sensing range
0 to 80 mm as standard diffuse
Time Delay 2 4 Output UV spot dimensions 0.12 x 0.04 " (3 x 1 mm) diameter
(1) Operation -13° to 131° F (-25° to 55° C)
3 (–) Temperature range
Storage -40° to 158° F (-40° to 70° C)
Photoelectric Sensors
Off delay: Enclosure rating IEC Type IP67 conforming to IEC 60529
For no delay, connect contact 2 to (+) Tightening Torque 15 N•m/11 lb-ft.
For 20ms delay, connect contact 2 to (-) Vibration 7G amplitude + 0.6 mm (f=10 to 55 Hz)
Shock resistance 30gn for 11 ms conforming to IEC 60068-2-27
1 +
4 LED indicator type Red - output
Enclosure material Nickel Plated Brass (window is PMAA)
3 – Sensitivity Adjustment 20 turn potentiometer
2
Connection M12, 4 pin connector
Without time delay
Light emission Ultra Violet
1 + Electrical DC models
4 Voltage Range 12 - 24 V (with SCP)
Voltage limit (including limit) 10 - 30 Vdc
3 –
2 Operating Frequency 1000 Hz
Current consumption (max.)(no load) 20 mA
With time delay (20ms)
Voltage drop (max.) 1.5V PNP
Power-up delay (max.) 100 ms
On delay (max.) 500 µs
Off delay (max.) 500 µs
Timing function 20 ms “off delay” selectable by wiring
E 164869 LR 44087
Agency Listings CCN NRKH Class 3211 03
®
0.79"
20 mm
spot : 3x1 mm
3.15"
80 mm
Diffuse Mode
WH 90% Kodak
2x2" (5x5cm)
Dual Dimensions inches
mm
89
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular, Plastic Body
Laser, Thru-beam Mode, DC
18 mm Tubular, Plastic Body / Laser, Thru-beam Mode, DC
Features
thread
M18x1 • Extremely long sensing distance of 100 meters (328 ft) in an 18mm tubular body
• Can detect very small objects
• Adjustable beam (or focus point) down to 0.5mm
• System checking and marginal detection LEDs
Photoelectric Sensors
• “Reserve Mode” option increases beam strength for visible alignment during setup
• Mounting nuts and adjustment screwdriver included
• Micro style connector standard c
• UL Listed, CSA Certified
Load
Circuit Output Voltage Operating
Current Catalog Number
Type Mode Range Frequency Max.
Max.
ON
1 +
2
2
3 –
OFF
1 +
2
3 –
1
The adjustment of the focusing point enables the detection of targets down XU2P18kP340DLR XU2P18KP340DLT
to a size of 0.5 mm.
To adjust the focusing point, loosen the fixing screws (1) and rotate the
serrated sleeve (2) located on the face of the sensor.
Re-tighten fixing screws.
Note: Saddle clamp XUZA218 incorporating a ball joint (see page 94) is
particularly suited for mounting the detector and adjusting the beam
alignment when the sensing range is several tens of meters.
cm 1.5
Signal 1
level 0.7
LED off
Red LED LED on
Optimum
Sn = 100 m – alignment
+
Operating precautions
CAUTION
LASER RADIATION —
DO NOT STARE INTO BEAM
90
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular, Plastic Body
Laser, Thru-beam mode, DC
18 mm Tubular, Plastic Body / Laser, Thru-beam Mode, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Emitter
Operation 14° F to +113° F (-10° C to +45° C)
Temperature range
1 (+) Storage -40° F to +158° F (-40° C to +70° C)
Enclosure rating IEC IP67 conforming to IEC 60529
2 4
Tightening torque (max.) 4 N•m (35.5 lb-in)
Test
Photoelectric Sensors
7 G, amplitude +/- 1.5 mm (f = 10 to 55 Hz)
3 (–) Vibration
conforming to IEC 60068-2-6
Receiver Shock resistance 50 gn for 11ms conforming to 68-2-27
Case PC/ABS
1 (+) Enclosure material
Lens PMMA
2 4
Wiring Micro style connector
Programm Output
ing Electrical
3 (–)
Voltage range 12 to 24 Vdc
Emitter Voltage limit (including ripple) 10 to 30 Vdc
4
–
3
Excess gain curve (ambient temperature: +25° C)
Dark mode (no object present)
Receiver mm
PNP output 12
10
1 +
Minimum size of the
object to be sensed
4 –
3 1
2
0.5
NPN output
1 + 0.1
4 0.1 0.3 1 2 10 20 100 (m)
– Focusing point
3
2
Dimensions
.157
4
(2)
(1)
(1) LED
91
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUB Plus 18 mm Short Body
Transparent Material Detection, DC
XUB Plus 18 mm Short Body / Transparent Material Detection, DC
2.17" Features
thread
55
M18x1 • Ultra short body
• Adjustable sensitivity
• Light/Dark selectable
• Short circuit and overload protection
1.34"
Photoelectric Sensors
34 • Advanced features: 360° multi-functional LED indicator: Output on, Marginal detection
indicator and short circuit indicator, and transparent object detection in retroreflective mode
2.17"
55 • UL Recognized, CSA Certified, CE Mark
Load
Circuit Output Voltage Operating
Current Catalog Number
Type Mode Range Frequency Max.
Max.
Retroreflective – 31.5" (80 cm) Nominal Sensing Range c - 2 m (6.6') cable (Reflector
sold separately)
1.34" 3 wire, PNP Light/Dark 12-24 V 100 mA 500 Hz XUBH01353
34
2.76" 3 wire, NPN Light/Dark 12-24 V 100 mA 500 Hz XUBJ01353
70
Retroreflective – 31.5" (80 cm) Nominal Sensing Range - Micro Style Connector f
(Reflector sold separately)
Dual Dimensions inches
mm 3 wire, PNP Light/Dark 12-24 V 100 mA 500 Hz XUBH01353D
3 wire, NPN Light/Dark 12-24 V 100 mA 500 Hz XUBJ01353D
c When used with XUZC50 reflector. 24" (60 cm) sensing range when used with XUZC24 reflector.
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
f See p. 518 for matching connector cables
(1) (1) 1
(2) 10 20 30 50 80 100 D (cm)
E
(1) 5 cm min.
(2) Sensor-reflector distance With reflector XUZC50
(see table below)
On
D On
ff
– LED
DO
Off
ent – LE
ED
– LE
Sensor-reflector distance
ent
–L
Material Reflector
ent
alignm
l alignm
nt
0 20 cm 40 cm 60 cm 80 cm
me
gnm
lign
li
XUZC50
al
a
Margina
ct a
Margin
t
Tinted glass
rrec
orre
XUZC24
Inco
Inc
XUZC50
PVC bottles
XUZC24
R
XUZC50
RED LED off Clear glass
XUZC24
RED LED on
XUZC50
PET bottles
XUZC24
XUZC50
PE film
XUZC24
92
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUB Plus 18 mm Short Body
Transparent Material Detection, DC
XUB Plus 18 mm Short Body / Transparent Material Detection, DC
Wiring Specifications
Mechanical
Connector For usable sensing range, see excess gain curve charts
1 (+) Temperature range -13° F to +131° F (-25° C to +55° C)
Program- 2 4 Output Enclosure rating IEC IP67 (IEC 60529)
ming
Enclosure material Case PC/ABS, Lens PMMA
Photoelectric Sensors
Vibration resistance 7 G, amplitude +/- 1.5 mm (f= 10 to 55 Hz)
Shock resistance 50 G, for 11ms
PNP output + light Cable: PvR, 0.16" (4 mm2) dia.
Prog.
OG
BN
- dark
Conductors: 24 AWG (0.222 mm2)
H
BR
Load
Electrical
BU
Voltage range 12 to 24 Vdc
Voltage limit (including ripple) 10 to 30 Vdc
Voltage drop (across switch), closed state 1.5 V
NPN output Maximum load current 100 mA
BN
J Current consumption (no load) 35 mA Retroreflective
BR Load
OG
+ light On delay (max.) 1 ms (1.5 ms thru-beam)
Prog.
- dark Off delay (max.) 1 ms (1.5 ms thru-beam)
Power-up delay (max.) 30 ms
Short circuit protection Yes
Overload protection Yes
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Protective Circuitry
Fast transients (motor start/stop
IEC 61000-4-4, L3a (1 kV)
interference)
Beam Pattern Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E 164353 LR 44087
cm Agency Listings CCN NKCR2 Class 3211 03
®
6
4 Physical Characteristics
E/R 2
Ambient light immunity 10,000 Lux
-2 .2 2 3
m Emitter wave length: Retroreflective 880nm Pulsed Infrared LED
-4 a L indicates level number.
-6 Sn: ≤ 2 m
Sn: ≤ 3 m Options
With reflector XUZC50 Description Suffix
Polarized reflex Extended cable length (5 meter (16’) cable) L05
Reflex Extended cable length (10 meter (33’) cable) L10
Accessories
Description Catalog Number
Mounting bracket (metal) 9006PA18
Universal mounting bracket (plastic) XSZB118
90° mirror adapter for side sensing (All other models)
PA18 XUBZ01
Decrease sensing distance by 20% (0.80)
XUBZ01
XSZB118
93
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
18 mm Tubular
Accessories, Replacements
18 mm Tubular / Accessories, Replacements
Accessories
Description Catalog Number
Plastic swivel ball mounting bracket (18 mm) XUZA218
Plastic mounting bracket XSZB118
Metal 90° mounting bracket 9006PA18
XUZA218 Zinc diecast 90° mounting bracket XUZA118
Plastic mounting nuts XSZE218
Photoelectric Sensors
94
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
18 mm Tubular
Accessories Dimensions
18 mm Tubular / Accessories Dimensions
Dimensions
XUZA218
.39 1.77 .73
10 Dia.
45 18.5
.31 .94 .31
8 24 8
.25
6.5
o
150
Photoelectric Sensors
.20
1.06
27
.98
25
5
19.5
.77
2.16 15 o
55
XUZA118
.10 .59
2.5 15
.73 .04
Dia. .39 .25
18.5 1
1.38 10 6.5
35
16.5
.65
1.10 .25 .79
28 6.5 20
1.97
50
XSZB118
1.51 .71
38.3 Dia.
18
.45
11.5
.87
22
20.1
.79
.14
.62 3.5
(1) 15.7
1.02
26
9006PA18
35
18 1.38
0.69 10 18 2
0.40 0.71 0.08
Full R
31 40 33
1.20 1.57 1.28
5
0.21
18 25 13 Dia. Hole
Dia Dual Dimensions inches
0.69 0.98 0.49 mm
0.22 0.76
1.4 5.75 19.5
0.76
19.5
∅ 0.72 M4 36 0.86
18.5 22.0
1.3
33
∅ 0.25
1.6
40
12 12.5
1.9
120
4.7
1.57
0.9 40
23
0.9
23
95
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM L Miniature
Classic Economy, DC
XUM L Miniature / Classic Economy, DC
Polarized Retroreflective – Nominal Sensing Range 13' (4m) a (Reflector sold separately)
2m cable
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0259
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0259
Connector Nano style-4 pin c
PNP Light/dark 12-24 V 100 mA 500 Hz XUMLH0259S
NPN Light/dark 12-24 V 100 mA 500 Hz XUMLJ0259S
96
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM L Miniature
Classic Economy, DC
XUM L Miniature / Classic Economy, DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
Emitter Temperature range -13° F to +131° F (-25° C to +55° C)
Test 2 4 NEMA Type 1, 3, 4, 6, 6P (cable only), 12, 13
Enclosure rating
IEC Type IP65 conforming to IEC 60529
1 3
+ – Enclosure material Housing: ABS/PC; Lens; PMMA, PC; Cable: PVC
Photoelectric Sensors
Vibration resistance 7G amplitude ± 1.5 mm (f= 10 to 55 Hz)
Shock resistance 50G 3 axes, 3 times
Receiver (reflex and prox diffuse) Wiring cable versions 6' cable, .18" dia., 3, 4 x #24 AWG
Light/dark Electrical
selector Output Voltage Limit q (including ripple) 10 - 30 Vdc
2 4
Load current max. 100 mA, protected against overload and short circuit
1 3 Voltage drop “closed” state 1.5 V
+ – No load current consumption max. 50 mA - receiver, emitter; 35 mA -reflex, diffuse
Test input voltage max. 1.5 V @ 1 mA max.
Receiver Switching frequency max. 500 Hz (400 Hz for thru beam)
PNP Output (Sourcing) Power up delay max. 30 ms
+ Light On/Off delay max. 1 ms (1.5 ms for thru beam)
Select
Polarized - red 660 nm
OG - Dark
Wavelength Proximity short range 660 nm
BN
H All others 880 nm
BK
BU
LOAD
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
NPN Output (Sinking)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
BN Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
H
BK E 164869 LR 44087
LOAD
100 20 20
2 2
10 10
1
5
1
10 5
1 1 1
0.1 1 10 2 10 20 50 100 200 500 1000 2 1 2 5 10 20 50 100
8 D (m) 400 D (cm) 40 D (cm)
With reflector 1 Polarized Target 10 x 10cm, 1 Short range
XUMZ0k XUZ C50 2 Infra-red White 90% 2 Standard diffuse
Thru-Beam Aperture
97
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature, High Performance
Classic, DC
XUM Miniature, High Performance / Classic, DC
High performance, self contained medium range miniature photoelectric sensors for industrial
applications.
Features:
• Very small dimensions: 1.4" x 0.87" x 0.39" (35.5 X 22 X 9.9mm) fixed.
• Marginal Detection Signal (MDS) provided for alarm output and alignment help.
Photoelectric Sensors
ns – Lim it e dE
P ro du c t PNP 3 wire Light /dark 12-24 V c 100 mA 500 Hz XUMH03353
Applicatio
NPN 3 wire Light /dark 12-24 V 100 mA 500 Hz XUMJ03353
Availability
On
D On
Off
ent – LE
LED
ED
e
alignm
l alignm
nt
nme
me
Margina
ct a
Margin
rrec
Inc
optical
axis
recommended
16" operating zone
A B
98
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature, High Performance
Classic, DC
XUM Miniature, High Performance / Classic, DC
Wiring Specifications
Mechanical
PNP output For usable sensing range, see excess gain curve charts
+ Light Temperature range -13° F to 131° F (-25° C to 55° C)
Select
OG - Dark
NEMA Type 1, 3, 4, 6, 6P, 12, 13
Enclosure rating
BN IEC Type IP67 conforming to IEC 60529
H BK
LOAD
Enclosure material Housing: ABS/PC; Lens: PMMA,PC; Cable: PVC
BU
Vibration resistance 7G amplitude ± 1.5 mm (f = 10 to 55 Hz)
Photoelectric Sensors
LOAD
W MDS Shock resistance 50G 3 axes, 3 times
Wiring 6’ cable, .18" dia., 3 x #24 AWG
Electrical
Voltage limit (including ripple) 10-30 Vdc
NPN output Load current max. 100 mA, protected against overload and short circuit
Voltage drop “closed” state 1.5 V
MDS
No load current consumption 30 mA - receiver; 20 mA - emitter 35 mA - reflex, diffuse
W
BN
LOAD
Test output current max. 50 mA
J BK LOAD Test input voltage max. 1.5 V @ 1 mA max.
BU
Switching frequency max. 500 Hz
+ Light
OG SELECT Power up delay max. 1 ms
- Dark On/Off delay max. 1 ms
Polarized 660 nm
Wavelength Convergent (red) 660 nm
All others 880 nm
Beam break test (purple wire) Ambient light immunity 10,000 LUX
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
E DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Brown + Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
ns – Lim it e d P ro du c t
Blue - a L indicates level number.
Applicatio
Beam present Options
Description Selected Versions Suffix
Availability
5m (16') cable on selected versions t L05
E 10m (33') cable on selected versions c L10
Brown +
Accessories
Purple
Description Sensing Distance Catalog Number
Thru-beam aperture (1) 0.5 mm and (1) 1 mm 4.5 cm (1.78") XUMZ01
Thru-beam aperture (1) 1.5 mm and (1) 2 mm 4.5 cm (1.78") XUMZ03
Blue -
Beam broken
Excess gain curves
Thru-beam Reflex Diffuse
gain gain gain
100
0 target 20 X 20
500 RF 30
300 50
white 90 %
40
0.7 m
100 20 20
50 15 infrared 15
10 10 0.1 m
7 9
10
5 3 3
99
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact
Classic – AC/DC, DC with Timer
XUK SubCompact / Classic - AC/DC, DC wtih Timer
Features:
• Increasingly popular rectangular body style perfect for mounting flat against machine wall
• Versatility is incorporated in every mode of detection
• Universal features makes retrofit easy
• 10 sec., three mode programmable time delay
Photoelectric Sensors
1.34
1.57
34
n s –
Ø4,5
Applicatio
2.30
58 included)
Cable style - 2 Meter (6.6’) length c
Availabil
1.57
le
50
d
20
High Percision
.71 .86
18 22 PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK5AKSAL2
Micro style connector
Ø6x12 .47 .27 PNP/NPN Light/Dark 12 - 24 V 100 mA q 1000 Hz XUK5AKSAM12
12 7
Proximity Diffuse – 1 m (3.3') Nominal Sensing Distance – Adjustable High Precision
Cable style - 2 Meter (6.6’) length c
2.30
.71
58
18
10 4
82
7 10
10
2 3
8
5 3 2
3.15
6
80
4
1 1
0,1 0,2 0,4 0,8 2 4 6 10 20 30 0,7 1,5 3 5 7 10 20 70 100 1 2
0,6 1 8 D (m) 1 2 30 50 D (m) 0 0,5 1 1,5 2
D (m) 0
With Reflector 1. Polarized Retroreflective 0 20 40 60 80 100
2. Retroreflective 1 White 90 % 3 Black 6%
2 Gray 18%
100
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact
Classic – AC/DC, DC with Timer
XUK SubCompact / Classic - AC/DC, DC with Timer
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3
Temperature range Operation -13° to 131° F (-25° to 55° C)
Storage -30° to 158° F (-30 to 70° C)
1 2
Enclosure rating NEMA Type 4, 4X (indoor), 12, 13
IEC Type IP65 conforming to IEC 60529
PNP Yellow on
Vibration 7G amplitude (f=10 to 55 Hz) Conforming to IEC 60068-2-6
Photoelectric Sensors
BN + Shock resistance 10gn for 11 ms conforming to 68-2-27
BK Wiring 22 AWG (.34 mm2)
– Tightening torque (max.) 5 N•m (44.4 lb-in)
BU
Case PC/ABS
Enclosure material Lens PMMA
Cable PvR
NPN Yellow on Electrical
AC/DC DC
BN + Voltage limit (including ripple) 21.6 - 264 Vac 10 - 30 Vdc
BK Voltage drop (across switch, closed state) — 1.5 V
–
BU Current consumption (max.)(no load) — 35 mA with SCP
Yellow Output LED yes yes
Red Stability LED no yes
Relay Wiring Power-up delay (max.) 60 ms 80 ms
On delay (max.) 25 ms 0.5 ms
Light switching (no object present)
Thru-beam receiver and reflex Off delay (max.) 25 ms 0.5 ms
Diffuse Short Circuit Protection —
BN BN
GY GY Protective Circuitry Overload Protection yes
WH WH
Reverse polarity protection — yes
n s
Diffuse
– L im ite d P ro d u c t BN
Options
Applicatio
GY GY
WH WH
BK BK Description Suffix
BU BU
8
10 Meter (33’) length cable L10
Transmitter
it y E x c e p t fo r X U K
Availabil
1.L.ON D.ON
BN 6 2.TIM. ON OFF Timing Function
y D if
BU
High Percision
4 4.On Delay / Off Delay
BU (Blue) 7 T 8
BN (Brown) 5 5.PNP or NPN
Relay common WH (White) T = Time delay
N.O. contact BK (Black) 6.Yellow LED - output on
N.C. contact GY (Grey) 3.DL 1 SHOT
7.Red LED - alignment and alarm
4.ON OFF
5. PNP NPN 8.Self teaching button (SET)
Recommended mounting
distances Detection Curves
max. 1.5 m
Thru-beam Retroflective Proximity Diffuse
min. 0
Dia. of beam (Copn) (Copn)
cm cm
10 cm
10
8
5 Ø 16 mm 5 4
20 30 m 0,2
5 7 10 m
-4
1 m
-5 -5
-8
-10 -10 Sn ≤ 1 m
Sn 5 m (1)
Sn 20 m Sn 7 m (2)
101
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUC Compact Limit Switch Body Style
DC or AC/DC Timer
XUC Compact Limit Switch Body Style / DC or AC/DC Timer
Features:
• Sleek but rugged compact body with • Two 360° LED indicators (output and
very long sensing distances stability)
• Solid state (NPN or PNP selectable) or • Light/Dark selectable
Relay output (N.O./N.C.) • Hinged transparent cover protects
• Built in 0-15 second timer option on adjustments
Photoelectric Sensors
3.06 Proximity Diffuse with Adjustable Background Suppression – 1.2 M (3.9') Nominal
78
Sensing Distance d
150°
1.73 Cable style – 2 Meter (6.6') length
44
AC/DC relay f Light/Dark 24 - 240 3A 20 Hz XUC8ARCTL2
PNP/NPN Light/Dark 12 - 24 V 100 mA 500 Hz XUC8AKSNL2
Sn 50 m Sn 6 m Sn 1.2 m
Thru-Beam Retroflective Diffuse
102
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUC Compact Limit Switch Body Style
DC or AC/DC Timer
XUC Compact Limit Switch Body Style / DC or AC/DC Timer
Photoelectric Sensors
Delay
Range T1 T2 Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
1 2 Light T1 T2 Time
6789 Case PC/ABS
On 0 to 2s Delay
Enclosure Material Lens PMMA
6 7 8 9 Cable PvR
Dark 0 to 15s Delayed Electrical
3 4 5 On One Shot
AC/DC DC
T2
T1 Voltage limit (including ripple) 20 - 264 Vac/dc 10 - 38 Vdc
LED Potentiometers
1 Output 3 Sensitivity
Voltage drop (across switch, closed state) — 1.5 V
2 Instability 4 T1 50 mA (thru-beam)
Power current consumption (max.) (no load) 2W
5 T2 35 mA (others)
Switches
6 Light On / Dark On Power-up delay (max.) 60 ms 15 ms
7 T1 = On Delay Time 0-2s or 0-15s On delay (max.) 25 ms 1 ms
8 T2 = Off Delay Time or One Shot Off delay (max.) 25 ms 1 ms
Time 0-2s or 0-15s
9 Time Delay / One Shot: 0-2s or 0-15s Red LED: stability yes no
Yellow LED: output yes yes
Wiring E164869
Agency Listings CCN NRKH
AC/DC (5-Wire ) ®
Transmitter
BN/4
Options
BU/2 Description Suffix
Light switching (no object present) 5 Meter (16.4') Cable L5
Thru-beam receiver and reflex
BN/4
Diffuse
BN/4 Mounting Brackets
WH/5 WH/5
GY/3 GY/3
BK/1 BK/1 Description Catalog Number
BU/2 BU/2
Swivel Ball Bracket (plastic) XSZSB30
Dark switching (no object present)
Thru-beam receiver and reflex 90 ° Bracket (steel) 9006 PA30
Diffuse
BN/4 BN/4
WH/5 WH/5
Excess gain curve (ambient temperature: +25° C)
GY/3 GY/3
BK/1 BK/1
BU/2
Thru-beam system Reflex system With reflector Variation of usable sensing distance
BU/2
gain gain XUZ-C50 Diffuse system with adjustable
Connector schemes XUC•ARCTU78 10000 background suppression
Thru-beam Thru-beam receiver, 40 B
transmitter reflex and diffuse 1000 30
3 Relay Common 20
3
4 2 4 2 100 10
5 1 5 1 5
N.C. N.O. 10 A 0.05 1.10 1.50 S (m)
Cable connections XUC•ARCTL• 1.30
BU (Blue) 1 1 A-B : Object reflection coefficient
BN (Brown) 1 2 5 10 80100 0.1 0.2 0.4 0.8 2 3 5 7 10 Black 6% Sensing range
Relay common GY (Grey) D (m) 0.6 1 4 6 9 D (m) Grey 18% Non sensing zone
N.O. contact BK (Black) White 90%
N.C. contact WH (White)
Connector Cables
(M12 or D suffix; U78 or A suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCA1501Y Mini Conn., 5 pin, 2 m, straight
XSZCA9501Y Mini Conn., 5 pin, 2 m, 90°
For additional cable options and lengths see p. 518
103
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUL Sub-compact
DC, AC/DC
XUL SubCompact / DC, AC/DC
Features:
• Subcompact medium range self contained • Side or front mounting
photoelectric sensors for industrial • LED visible from two directions (front, top)
applications
• Easy to wire (45° cable entry)
• DC or AC/DC solid state output, AC/DC
• Cable or connector options available ➁
relay output
• 2-wire solid state output saves wiring time
Photoelectric Sensors
n s – L im ite d P ro d u c t
AC/DC – 6' (2 m) cable
Applicatio
Solid state output Light 20-264 V 20-60 V 500 mA 20 Hz XULA06021
Solid state output Dark 20-264 V 20-60 V 500 mA 20 Hz XULA06011
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM06031
Availability
DC – 6' (2 m) cable
3 wire PNP Light/Dark – 10-30 V 200 mA 250 Hz XULH06353
3 wire NPN Light/Dark – 10-30 V 200 mA 250 Hz XULJ06353
Polarized Retroreflective – Nominal Sensing Range 16' (5 m) a (Reflector sold separately)
AC/DC – 6' (2 m) cable
Solid state output Light 20-264 V 20-60 V 500 mA 20 Hz XULA040219
Solid state output Dark 20-264 V 20-60 V 500 mA 20 Hz XULA040119
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM040319
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH043539
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ043539
Proximity Diffuse – Nominal Sensing Range 2.3' (.7 m) a
AC/DC – 6' (2 m) cable
Solid state output Light 20-264 V 20-60 V 500 mA 200 Hz XULA700115
Solid state output Dark 20-264 V 20-60 V 500 mA 200 Hz XULA700215
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH703535
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ703535
Proximity Diffuse w/ Background Suppression – Sensing Range – 0.15' (0.3 m) ➀ a
AC/DC – 6' (2 m) cable
5 wire, relay output Light 20-264 V 20-60 V 2A 20 Hz XULM300318
DC – 6' (2 m) cable
3 wire PNP Light/dark – 10-30 V 200 mA 200 Hz XULH303538➂
3 wire NPN Light/dark – 10-30 V 200 mA 200 Hz XULJ303538➂
Proximity Diffuse w/ Adjustable Background Suppression: Sensing Range – 0.5 - 0.15 m a
DC – 6' (2 m) cable
3 wire PNP Light/dark – 12-24 Vdc 200 mA 200 Hz XULH153538
3 wire NPN Light/dark – 12-24 Vdc 200 mA 200 Hz XULJ153538
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Fixed, no sensitivity adjustment.
➁ See p. 518 for matching connector cables.
➂ Supplied with potentiometer to adjust range between 15 and 30 cm.
k 20 < Vdc < 58 IEC 60947-5-2 Utilization category DC-13. Vdc > 58 IEC 60947-5-2 Utilization category DC-12.
104
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUL Sub-compact
DC, AC/DC
XUL SubCompact / DC, AC/DC
Wiring Specifications
Mechanical
Connector
For usable sensing range, see excess gain curve charts
4 3 1
Temperature range -13° F to 140° F (-25° C to 60° C)
NEMA Type 1, 3, 4, 6, 6P, 12, 13
2 3 Enclosure rating
1 2 CENELEC Type IP67 conforming to IEC 60529 and IP671 conforming to NFC 20-010
Enclosure materials Housing: ABS/PC Lens: PMMA Cable: PVC
Vibration resistance 7 G, mm amplitude (f = 10 to 55 Hz)
DC AC/DC
Photoelectric Sensors
Shock resistance 20 G for 11 ms
Emitter Emitter Wiring 6' (2 m) cable, 0.2" OD, 4 x 22 AWG or 2 x 22 AWG
BN BN AC/D
Electrical DC Models Relay AC/DC Model solid state
BU BU AC/D Voltage range - 24-240 Vac/dc 24-240 Vac/dc
Leakage current 1.7 mA 1.5 mA 1.7 mA AC; 1.5 mA DC
Minimum load current 0 mA 0 mA 5 mA
DC Receivers 3 wire
Power Supply Current (no load) 30 mA 5 mA (emitter) 25 mA (all others)
Cable, PNP On delay max. 4 ms 25 ms 25 ms
BN
BK Off delay max. 4 ms 25 ms 25 ms
BU Power up delay max. 15 ms 60 ms 60 ms
Wavelength 880 nm 880 nm 880 nm
Select OG + light
- dark
Polarized 660 nm 660 nm 660 nm
Cable, NPN Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
BN DC 2 wire: IEC 61000-4-2, L3a (8 kV)
BK
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
BU Protective Circuitry
AC/DC: IEC 61000-4-2, L3a (8 kV)
+ light
Select OG
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
- dark
Connector, PNP Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
1 E164353 LR44087
4 Agency Listings CCN NKCR Class
®
3 3211 03
n s – L im it
4
e
3
d P ro d u c t Description
Micro style DC receptacle (DC models only) See p.518 for matching connector
Suffix Adder
D
Applicatio
+ light cables
Select 2 Micro style AC/DC receptacle (AC\DC models only) K
- dark 16' (5 m) cable L05
33' (10 m) cable L10
Availability
AC/DC Receivers:
Example: XUL 08014L10
Relay Solid state
BK
OG
AC/DC
- BN AC/DC
Accessories
RD
BN AC/DC BU AC/DC Description Catalog Number
BU
Mounting bracket (Included) XULZ41
target 20x20 cm
500 50 white 90 %
50 10
30 30 7
25 25 RF 30
100
15 15 5
50 RF 30 Polarized 4
10 10
7 7 3
10
5 3 3 2
Diffuse system with adjustable background suppression XUL•15•••• Diffuse system with adjustable background suppression XUL•30••••
Potentiometer at minimum Potentiometer at maximum Potentiometer at minimum Potentiometer at maximum
B B B B A-B: Object reflection coefficient
A-B: Object reflection coefficient
Black 6% Black 6%
Grey 18% Grey 18%
White 90% White 90%
Sensing range Sensing range
Non detection zone Non detection zone
(Matt surfaces) (Matt surfaces)
A A
A 0.01 0.15 S (m) A 0.01 0.20 0.35 S (m) 0.01 0.07 S (m) 0.01 0.17 S (m)
0.10 0.20 0.30 0.05 0.15
Connector Cables
(M12 or D suffix; U20 or K suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
XSZCK101Y Mini Conn., 5 pin, 2 m, straight
XSZCK111Y Mini Conn., 5 pin, 2 m, 90° Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 166
Reflectors . . . . . . . . . . . . . . . . . . . . . . . . . . Page 156
For additional cable options and lengths see p. 518 Sensing pattern. . . . . . . . . . . . . . . . . . . . . . Page 159
105
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ L Compact Economy
AC/DC
XUJ L Compact Economy / AC/DC
Compact rectangular long range Economy self-contained photoelectric sensors for demanding
industrial application.
Features:
• Housings: high performance synthetic resin (ULTEM™) ➁
• Reduced condensation on the lenses at heat/cold changes
Photoelectric Sensors
Polarized Retroreflective – 24' (7.3 m) Nominal Sensing Range ➀ a (Reflector sold separately)
AC/DC relay
N.O.+N.C. Light 20-264 V 20-60 V 2A 20 Hz XUJLM0619
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Range when used with RF30 or XUZC50 reflector.
➁ ULTEM is a GE plastics trademark.
k 20 ≤ Vdc ≤ 58 IEC 60947-5-2 Utilization category DC-13
Vdc ≥ 58 IEC 60947-5-2 Utilization category DC-12
106
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ L Compact Economy
AC/DC
XUJ L Compact Economy / AC/DC
Wiring Specifications
Mechanical
Connector
3 For usable sensing range, see excess gain curve charts
1 3
4 2 Temperature range -13° F to +131° F (-25° C to +55° C)
Photoelectric Sensors
Light mode: output is energized when Shock resistance 30 G, for 11 ms
target is not present Wiring - screw terminals #16 AWG
Electrical
Power supply current (no load) (max.) 30 mA
1 L1/– Relay contract voltage rating (max.) 250 Vac
2
L2/+ On delay (max.) 25 ms
5 Off delay (max.) 25 ms
4 Power up delay (max.) 60 ms
3
880 nm
Wavelength
5 Wire Relay AC/DC Polarized 660 nm
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
Electrostatic discharges AC/DC: IEC 61000-4-2, L3a (8 kV)
Protective Circuitry Fast transients (motor start/stop
1 IEC 61000-4-4, L3a (1 kV)
L1/– interference)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
2
L2/+ E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
®
Emitter
a L indicates level number.
Options
Description Matching Connector Cables Suffix
Metric cable entry PG9 P9
Receptacle mini style 5 pin - AC/DC models XSZCA1501Y R5
Receptacle mini style 3 pin - N.O. output XSZCA901Y R30
Receptacle mini style 3 pin - N.C. output XSZCA901Y R31
For additional cable options and lengths see p. 518
Accessories
Description Catalog Number
Protective Cover - bottom entry, metric XUJZ09
Alignment tool XUZD09
“Universal” mounting bracket (included) XUZA49
Thru-beam aperture 0.11" (3 mm), sensing distance 39.4" (1 m) XUJZ02
Thru-beam aperture 5 mm dia. (1 m sensing) XUZ202
10 10 10
50 5 5
1 1 1
50.1 0.2 0.4 1 2 4 10 1520 0.1 0.2 0.4 1 2 4 8 10 0.1 0.2 0.4 1 2 4 6 10
D (m) D (m) D (m)
* with reflector RF30
107
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ Compact Universal
DC, AC/DC
XUJ Compact Universal / DC, AC/DC
Compact rectangular long range self contained photoelectric sensors for demanding industrial application.
Features:
• Housings: high performance synthetic • Marginal Detection Signal (MDS) test
resin (ULTEM™) ➂ output for DC models
• Reduced condensation on the lenses at heat/cold • AC/DC models available with separate
changes (independent) ON and OFF delay timer
Photoelectric Sensors
• 0.5" NPT conduit entrance is standard (metric • Reverse polarity protection for DC models
version available) • Noise and transient protection
• FINGER GUARD™ isolated terminals in “ready- • Short circuit protection (SCP) standard for DC
to-wire” position models
Alignment Operation
• Double insulated (no grounding required) • 2 LED alignment system with 360° visibility
• Adjustments protected by optional cover • Light/Dark selectable (by wiring) output function
E • Infrared modulated LED emission for a high • Sensitivity adjustment and mounting bracket
ambient light immunity (visible red for polarized allows easy alignment in 2 planes (included)
models) • Analog proximity diffuse available: Page 110.
On
D On
Off
– LED
ED
ent
–L
l alignm
men
l alignm
nt
lign
Margina
ct a
Margin
Max. Max.
rrec
orre
Inco
Emitter AC/DC
– – 20-264 V 20-60 V – – – XUJM1000
R
Receiver DC
RED LED off
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK103534
RED LED on Receiver AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM100314
Receiver AC/DC relay with timer (.25s to 15s)
Test Output N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT100314
Retroreflective – 29.5' (9 m) Nominal Sensing Range ➀ a (Reflector sold separately)
Red LED
MDS DC model
t t
output PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK06353
signal AC/DC relay
State 0 : output connected to -
State 1 : output connected to + N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM06031
t = 160 ms* AC/DC relay with timer (.25s to 15s)
* time delay to avoid nuisance signals N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT06031
Polarized Retroreflective – 26.2' (8 m) Sensing Range ➀ a (Reflector sold separately)
DC model
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK063539
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM060319
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 Vac 20-60 V 2A 20 Hz No XUJT060319
Proximity (Diffuse) w/ Background Suppression – 27" (70 cm) Sensing Range ➁ ➃ a
DC model
PNP/NPN Light/Dark – 10-38 V 200 mA 200 Hz Yes XUJK703538
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM700318
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT700318
Proximity (Diffuse) w/ Background Suppression – 48" (1.2 m) Sensing Range ➁ ➃ a
XUZD09 DC model
Alignment Tool PNP/NPN Light/Dark 10-38 V 200 mA 200 Hz Yes XUJK123538
AC/DC relay
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJM120318
AC/DC relay with timer (.25s to 15s)
N.O.+N.C. Light/Dark 20-264 V 20-60 V 2A 20 Hz No XUJT120318
a Excess gain one - in normal ambient conditions, maximum usable sensing distance is 75% of normal.
➀ Range when used with RF30 reflector.
➁ With white 90% Kodac 20 x 20 cm (8" x 8")paper.
➂ ULTEM is a GE plastics trademark.
➃ Analog Proximity (diffuse) with background suppression - see page 110.
108
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ Compact Universal
DC, AC/DC
XUJ Compact Universal / DC, AC/DC
Wiring Specifications
Mechanical
Emitter For usable sensing range, see excess gain curve charts
1 Temperature range -13° F to 140° F (-25° C to 60° C)
NEMA Type 1,3,6,12,13
3 Enclosure rating IP67 conforming to IEC 60529 and IP671 conforming to NFC 20-
IEC Type
010, double insulated
Test Output (thru-beam & reflex) Vibration resistance 7 G, 1.5 mm amplitude, f=10 Hz to 55 Hz
2/3 Shock resistance 30 G, for 11 ms
Photoelectric Sensors
NPN Wiring - screw terminals #16 AWG
6 PNP
Electrical AC models DC models
1
Voltage drop across switch (max.) 0 1.5 V
Light switching (no object present) Power supply current (no load) (max.) 45 mA 30 mA
Thru-beam receiver & reflex Relay contract voltage rating (max.) 250 Vac –
On delay (max.) 25 ms 2 ms
PNP output
Off delay (max.) 25 ms 2 ms
3
Power up delay (max.) 60 ms 15 ms
5 880 nm 880 nm
Wavelength
1 Polarized 660 nm 660 nm
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
NPN output
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
3
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
4
Protective Circuitry AC/DC: IEC 61000-4-2, L3a (8 kV)
1 Fast transients (motor start/stop
IEC 61000-4-4, L3a (1 kV)
interference)
Diffuse Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
PNP output E164353 LR44087
2 Agency Listings CCN NKCR Class 3211 03
®
5
a L indicates level number.
1
NPN output Options
2 Description Matching Connector Cables Suffix
4 Metric cable entry PG9 P9
1 Receptacle micro style DC XSZCD101Y D1
Receptacle micro style DC - bottom XSZCD101Y D2
Receptacle mini style 5 pin - AC/DC models XSZCA1501Y R5
Dark switching (no object present) Receptacle mini style 3 pin AC or AC/DC modelst XSZCA901Y R3
Thru-beam receiver & reflex
For additional cable options and lengths see p. 518
PNP output
t NPN output, dark – standard. For other configurations contact plant.
2
5 Accessories
1 Description Catalog Number
NPN output Alignment tool XUZD09
2 Protective cover (top) XUJZ01
4 Mounting bracket (included) XUZA41
Thru-beam aperture 0.11" (3mm), sensing distance 39.4" (1m) XUJZ02
1
Diffuse
Excess Gain Curves
PNP output
3 Thru-beam (Temp : 25°C) Infrared reflex (Temp : 25 °C) Polarized reflex (Temp : 25 °C)
5 gain gain
1 500
NPN output
40 40
3 100
30 30
4 50 20 20
1 10 10
10
5 5
Terminal connections 5
Solid state output
D (m) RF 30 D (m) RF 30 D (m)
1 — (-)
1 1 1
2 — (+) 0.1 0.2 0.4 0.6 0.8 1 2 3 456 10 15 20 0.1 0.2 0.4 0.60.8 1 2 3 4 5 6 910 0.1 0.2 0.4 0.6 0.81 2 3 4 5 6 7 910
109
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJ Analog with Background Suppression
Analog Output — DC
XUJ Analog with Background Suppression / Analog Out - DC
2.40 Features:
61 LED
• Distance indication (measurement) that is independent of target color or texture.
• Elimination of background influence.
• Dual outputs 4-20 mA and 0-10 Vdc (Selectable).
.10
• Long range proximity (Diffuse) with background suppression 20-80 cm (7.87" - 31.50").
2.6
Photoelectric Sensors
• LED indicator which gives an illumination level proportional to the output voltage.
.66
17
.39 .78
• UL Listed, CSA Certified, CE Mark
.35
10 20 9 3.29
83.6
Applications:
A : 1/2" NPT • Bulk or liquid level control.
B : 1 elongated hole Ø 4.2 x 14
• Thickness monitoring.
• Winder speed control.
• Position indication for feedback to drives and similar devices in web control applications.
1.07 • Size sorting such as fruit and vegetables.
1.35
.05
27.2
13
E
1.18*
30
98.85
3.89
2.46
62.5
10 10
1.28
32.6
* Front mounting
(Ø 4 screws and inserts supplied)
110
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUJ Analog with Background Suppression
Analog Output — DC
XUJ Analog with Background Suppression / Analog Output - DC
Wiring Specifications
Connector Mechanical
3 Temperature range -13° F to 140° F (-25° C to 60° C)
4 2 NEMA Type 1,3,6,12,13
Enclosure rating IP67 conforming to IEC 60529 and IP671
5 1 IEC Type
conforming to NFC 20-010, double insulated
Vibration 7G, 1.5 mm amplitude, f =10 Hz to 55 Hz
Photoelectric Sensors
1 – (-) Comm. Shock resistance 30G for 11 ms
Wiring – screw terminals #16 AWG
2 –
Electrical
Voltage limit (including ripple) 20-30 Vdc
3 – (+) 24 Vdc
Power supply current (no load) 40 mA
4 – Vs Operating frequency maximum 50 Hz
Voltage output 0-10 Vdc
5 – Is Current output 15 mA
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
6 – (-) Com. DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges
Protective Circuitry DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
Note: Terminals 1 and 6 are
internally connected. Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
®
Options
Description Matching Connector Cables Suffix Adder
Receptacle mini style 5 pin XSZCA1501Y R5
For additional cable options and lengths see p. 518
Accessories
Catalog
Description
Number
Protective cover (top) XUJZ01
Mounting bracket (included) XUZA41
10V 20
OV
15 20 80 D (cm) 15 20 80 D (cm)
111
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Long Range, Plug In
AC/DC, DC
XUE Long Range, Plug In / AC/DC, DC
Plug-in rectangular long range self contained photoelectric sensors for demanding industrial
applications.
Features:
• Housing: epoxy filled plastic (thermoplastic • AC/DC models available with programmable
polyester) timers
• Selected models are offered in low • Reverse polarity protection for DC models
Photoelectric Sensors
112
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE Long Range, Plug In
AC/DC, DC
XUE Long Range, Plug In / AC/DC, DC
Wiring Specifications
Connector Mechanical AC Models DC Model
1 3 3 For usable sensing range, see excess gain curve charts
4 2 -13° F to 158° F (-25° C to 70°
Temperature range -13° F to 131° F (-25° C to 55° C)
C)
2 5 1
NEMA Type 1, 3, 4, 13 1, 3, 4, 13
Enclosure rating IP67 conforming to IEC 60529 and IP673 conforming to NFC 20-
IEC Type IP67
010
DC Emitter
AC/DC emitter
Photoelectric Sensors
L1 L2 Vibration resistance 7 G @ 0.6 mm Amplitude 7 G @ 0.6 mm Amplitude
Brown XUEH and XUEA 30 G for 11 ms 10 G for 11 ms
A1 Shock resistance
XUEF and XUET 20 G for 11 ms
Blue Electrical
A2
5mA (XUEA);
Minimum switching current
15mA for relay output
Thru-Beam Reflex/Prox Thru-Beam Reflex/Prox Background
Power supply current (no load) 45 mA 35mA
XUEA… On delay (max) 25 ms 25 ms 2.5ms 1.5ms 8ms
2 wire AC/DC Off delay (max) 30 ms 30 ms 2ms 1ms 8ms
L1 L2
Power up delay 120 ms 80 ms 70ms 27ms 30ms
A1 Wavelength 880 nm 880 nm 880nm 880nm 880nm
LOAD Polarized – 660 nm – 660nm –
A2 Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V/M)
DC 2 wire: IEC 61000-4-2, L3a (8 kV)
Electrostatic discharges DC 3 wire: IEC 61000-4-2, L2a (4 kV)
Protective Circuitry
AC/DC: IEC 61000-4-2, L3a (8 kV)
XUEH… Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
H NPN - Sinking Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
N E164353 LR44087
Agency Listings CCN NKCR Class 3211 03
LOAD ®
Accessories
XUEF… Description Suffix Min. Quantity
A1
Mounting bracket (included) XUZA44 1
F L1
12 Glass lens cover and sun shade XUZD02 1
N/C
11 Alignment tool XUZD09 1
COMMON
13 Fuse 0.8A fast blow – for XUEA XUZE08 10
N/O
A2 L2
De-Energized
Timing Features
XUET models (including the fiber optic model) feature a sophisticated timing circuit (0.03-60 sec.) which can be programmed via the
selector switches located under the top cover. In conjunction with the light-dark switch, the following functions can be implemented:
XUET…
A1 L1
T
16 N/C
15
COMMON Alignment
18
N/O LED's
ON Delay - on beam reception Sensitivity
A2 L2
De-Energized - on beam interruption On/Off adjustment
OFF Delay - on beam reception LED
- on beam interruption Light/Dark
Monostable (one shot) selector Timing
- on beam reception switch adjustment
- on beam interruption
Timer
selector
switches
(XUET only)
113
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Long Range, Plug-In
AC/DC, DC
XUE Long Range, Plug-In / AC/DC, DC
DC Output Sensors
Description Catalog Number
Wiring receptacle, 0.5" NPT cable entry ZUEZ03H7
Wiring Receptacle Wiring receptacle, metric (CM12) cable entry ZUEZ03
Switch body proximity, PNP/NPN ZUEH017535H7
Switch body retroreflective, PNP/NPN ZUEH10753H7
Switch body proximity with background suppression PNP/NPN ZUEH753538
Switch body thru-beam receiver PNP/NPN ZUEHB07534
(F1)
<t
Time delay on breaking of the beam:
(F2)
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2)
C4 t t t 0: relay de-energized 1: relay energized
C5
C6 0 Dark switching with output delay,
duration: 1 Receiver light: on
1
thru-beam and
t t t t
Dark switching with monostable (one shot) reflex system
0 period, duration: 1 detectors the light
beam is intact (no
1 Light switching with output delay, target present);
t t t duration: 1 on diffuse system
detectors light is
0 being reflected
Light switching with monostable (one shot)
1 period, duration: 1 back to the
t t t t receiver from the
target (target
0 present).
Receiver dark: on
(F1)
thru-beam and
<t reflex system
Time delay on breaking of the beam: detectors the light
(F2) beam is broken
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2) (target present);
C4 t t t 0: relay de-energized 1: relay energized on diffuse system
C5 detectors light is
C6 0 Dark switching with output delay, not being
1
duration: 1 reflected back to
t t t t the receiver from
Dark switching with monostable (one shot) the target (no
0 period, duration: 1 target present).
114
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE Long Range, Plug-in
Replacement Parts
XUE Long Range, Plug-In / Replacement Parts
Photoelectric Sensors
Switch Body Receiver AC/DC ZUET300314
2000
1000 50
400 XUZC24
20
100
10
70
7
10
RF 30
3
D (m)
D (m)
1 1
0.8 1 2 4 6 8 10 20 30 4050 100 0.1 0.2 0.4 0.6 0,8 1 2 3 5 7 910 15
50 30
target 20 x 20 cm
20
20 white 90 %
RF 30 10
10
7
7
5
3 3
D (m) D (m)
1 1
0.1 0.2 0.4 0.6 0.8 1 2 3 5 7 8 10 15 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 1.5 2 2.5
115
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFA Glass Fiber Optics and Amplifiers
Description, Selection
XUFA Glass Fiber Optics and Amplifiers / Description, Selection
.281" (7.1) The XUFA is one of the most versatile heavy duty glass core fiber optics in stainless steel
.187" (4.7)
sheetings available.
.125" (3.1)
Features:
Smooth, straight
• Coiled stainless steel sheathing withstands most aggressive environments while
maintaining a high degree of flexibility
• Transmission of light through the fiber optics is not affected by water, gasoline, oil, sulfuric
Photoelectric Sensors
1.5" (38.1)
.125" (3.1)
acid or other organic acids
Threaded, straight • Most common sensing tips are standard (Other tip configurations and cable lengths can be
1.1"
made on order - contact factory)
.281" (7.1)
28
• Very high temperature range -49° F to 527° F (-45° C to 275° C)
.8" (20.3)
• Two scanning modes are recommended: Thru-beam using a pair of cables (emitter-
Smooth, 90 .187" (4.7) receiver)
.125" (3.1)
• Proximity (diffuse) using a bifurcated cable with a triple sensing tip in which emitter and
28
.281" (7.1)
1.1" receiver fibers are mixed.
Note: With some precautions to avoid the proximity effect, the bifurcated cable can also be
.8" (20.3)
used in retroreflective scanning mode.
5/16-24
1.5" (38.1)
• AC/DC relay output, XUE model with timer
Threaded 90 • Selectable Light/Dark
.125" (3.1)
.75"(19)
Thru-beam (pair) (single emitter and receiver sold as a pair)
.46 (11.7)
Smooth, straight 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110213
.75"
19 Threaded, straight 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110113
.25" (6.3)
Window, short Threaded, straight 11.8" (30 cm) 12' (3.66 m) 0.125" (3.2 mm) XUFA1101112
Smooth, 90 ° 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110413
Threaded, 90 ° 11.8" (30 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA110313
Window, short 10" (25.5 cm) 36" (91.4 cm) 0.38" x 0.032" (9.65 mm x 0.81mm) XUFA110513
Proximity (bifurcated) (Y-shaped dual reflective type)
Smooth, straight 4.33" (11 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210213
Threaded, straight 5.51" (14 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210113
Threaded, straight 4.53" (11.5 cm) 12' (3.66 m) 0.125" (3.2 mm) XUFA2101112
Smooth, 90 ° 3.94" (10 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210413
Threaded, 90 ° 4.72" (12 cm) 36" (91.4 cm) 0.125" (3.2 mm) XUFA210313
Window, short 3.94" (10 cm) 36" (91.4 cm) 0.38" x 0.032" (9.65 mm x 0.81mm) XUFA210513
a Excess gain one – in normal ambient conditions, maximum usable sensing distance is 75% of normal.
116
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFA Glass Fiber Optics
Specifications
XUFA Glass Fiber Optics / Specifications
Photoelectric Sensors
Cable Screw terminals #16 AWG
XUET1401266
Electrical
A1 L1 Power supply current 45 mA
16
N/C Voltage drop across switch –
15
COMMON On delay 25 ms
18
N/O
A2 Off delay 30 ms
De-Energized L2
Power up delay 80 ms
Wavelength 880 nm
E164343 LR60942
Agency Listings CCN NKCR Class 4812 05
®
Accessories
Description Magnification factor (thru-beam) t Catalog Number
XUFAZ01 Lenses (pair) for threaded tips X10 XUFAZ01
Lenses (pair) for smooth tips X10 XUFAZ02
t Will improve range approximately 3 to 5 times
XUFAZ02
117
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUE Amplifier for XUFA Glass Fiber Optics
XUE Amplifiers for XUFA Glass Fiber Optics
Self-contained Amplifier
Circuit Type Output Mode Voltage Range Max. Load Current Max. Operating Frequency Catalog Number
N.O.+N.C. Light/Dark 20 - 264 Vac/dc 2A 20 Hz XUET1401266
See page 167 for dimensions
Timing Features
The XUE T model features a sophisticated timing circuit (.03-60 sec.) which
Photoelectric Sensors
can be programmed via the selector switches located under the top cover.
Alignment
In conjunction with the light/dark switch, the following functions can be
LED's
implemented. Sensitivity
on beam reception On/Off adjustment
ON delay:
on beam interruption LED
on beam reception Light/Dark
OFF delay: selector
XUET on beam interruption Timing
switch adjustment
(F1)
<t
Time delay on breaking of the beam:
(F2)
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2)
C4 t t t 0: relay de-energized 1: relay energized
C5
C6 0 Dark switching with output delay,
duration: 1 Receiver light: on
1
thru-beam and
t t t t
Dark switching with monostable (one shot) reflex system
0 period, duration: 1 detectors the light
beam is intact (no
1 Light switching with output delay, target present);
t t t duration: 1 on diffuse system
detectors light is
0 being reflected
Light switching with monostable (one shot)
1 period, duration: 1 back to the
t t t t receiver from the
target (target
0 present).
Receiver dark: on
(F1)
thru-beam and
<t reflex system
Time delay on breaking of the beam: detectors the light
(F2) beam is broken
C1 C2
C3 1 F1: beam intact (1) F2: beam broken (2) (target present);
C4 t t t 0: relay de-energized 1: relay energized on diffuse system
C5 detectors light is
C6 0 Dark switching with output delay, not being
1
duration: 1 reflected back to
t t t t the receiver from
Dark switching with monostable (one shot) the target (no
0 period, duration: 1 target present).
118
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUET Amplifier Specifications
XUET Amplifier Specifications
Wiring Specifications
XUET… Mechanical XUET
Operating -13° to 158° F (-25° to 70° C)
A1 L1 Temperature range
T Storage -13° to 158° F (-25° to 70° C)
16 N/C
15 NEMA Type 1
COMMON Enclosure Rating IP40 conforming to IEC 60529 and IP400 conforming to NFC
18
N/O IEC Type
20-101 with fibers connected
A2 L2
De-Energized Vibration resistance 7 G @ 0.6 mm amplitude
Photoelectric Sensors
Shock resistance 20 G for 11 ms
Electrical
Voltage Range 20 - 264 Vac/dc
Voltage Drop (Across Switch)
N/A
Closed State max.
Leakage Current N/A
Max Load Current 2A
Current Consumption -- No Load 45 mA max.
On delay max. 25 ms
Off Delay Max. 30 ms
Reverse Polarity Protection N/A
False Pulse Protection Yes
Line Transients No
2000
1000 50
400 XUZC24
20
100
10
70
7
10
RF 30
3
D (m)
D (m)
1 1
0.8 1 2 4 6 8 10 20 30 4050 100 0.1 0.2 0.4 0.6 0,8 1 2 3 5 7 910 15
50 30
target 20 x 20 cm
20
20 white 90 %
RF 30 10
10
7
7
5
3 3
D (m) D (m)
1 1
0.1 0.2 0.4 0.6 0.8 1 2 3 5 7 8 10 15 0.05 0.08 0.1 0.2 0.4 0.6 0.8 1 1.5 2 2.5
119
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN Plastic and XUFS Glass Fiber Optics
XUFN Plastic and XUFS Glass Fiber Optics
Features
XUFN series of plastic core fiber optics provides flexibility in usage at an affordable price.
Threaded
• Smooth plastic jacket (polyethylene) in • Standard separate emitter-receiver bundles
straight or coiled versions, withstands most or randomized receiver with an emitter core
3.5" Flexible nozzle
industrial environments including food for very near detection are available. Note:
processing and pharmaceuticals with some precautions to avoid the proximity
Photoelectric Sensors
• Straight cable standard effect, the bifurcated cable can also be used
in retroreflective scanning mode
• Threaded and flexible nozzle tips
• XUFS series of glass core fiber optics
• Suitable for very small part detection
provides raggedness, higher temperature
Coiled cable
• Two scanning modes are recommended ratings and excellent withstanding in
• Thru-beam using a pair of cables (emitter- aggressive/chemical environments
receiver), Proximity (diffuse) using a • Coiled fiber cable for applications with
bifurcated cable with a single sensing tip in significant movement between the amplifier
which emitter and receiver fibers are mixed and the sensing tip
Plastic Fiber Optics
Flexible nozzle, coiled cable Sensing distance, Sn a Beam Cable Catalog
Tip
(max.) standard w/XUFZ01 lenses Diameter Diameter (OD) Number
Thru-beam (pairs) – 6.6' (2 m) long (single emitter and receiver sold as a pair)
Straight cable
Threaded 9.84" (250 mm) 73.68" (1.87 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN12301a
.6" Flexible nozzle 33’ (10 m) Threaded 4.43" (113 mm) 44.30" (1.13 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN12301L10a
Threaded 2.46" (62 mm) 19.68" (0.5 m) 0.02" (0.5 mm) 0.04" (1 mm) XUFN35301
3.5" Flexible nozzle 8.85" (225 mm) – 0.04" (1 mm) 0.09" (2.2 mm) XUFN12311
3.5" Flexible nozzle 2.48" (63 mm) – 0.02" (0.5 mm) 0.04" (1 mm) XUFN35311
Coiled cable
Threaded 7.30" (185 mm) 49.2" (1.2 m) 0.04" (1 mm) 0.09" (2.2 mm) XUFN10302
Direct plug 3.5" Flexible nozzle 7.30" (185 mm) – 0.04" (1 mm) 0.09" (2.2 mm) XUFN10312
3.5" Flexible nozzle 0.89" (23 mm) 2 x 0.02" (0.5 mm) 0.04" (1 mm) XUFN01331
Ø0.15 0.6" Flexible nozzle 0.30" (7.5 mm) 2 x 0.01" (0.265 mm) 0.04" (1 mm) XUFN04331
13
Coiled cable
Ø0.2 Threaded 1.00" (25 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN15322
5
3.5" Flexible nozzle 1.00" (25 mm) 2 x 0.04" (1 mm) 0.09" (2.2 mm) XUFN15332
38.2970
Direct plug
M0.1 (2.6) 0.02" (0.5 mm)+ 8 x
3.5" Flexible nozzle 1.48" (37 mm) 0.06" (1.5 mm) XUDZ01
M4 0.01" (0.265 mm)
1.0
25
➀ Not recommended for very short sensing distances under 0.2" (5 mm) (coherent).
➁ Recommended for very short sensing distances (randomized).
Ø0.16
38.2
970
a Sensing distances change when used with ZUCN0016, ZUCN0017 and XUET1401266 amplifiers. Contact Square D for information and
5
beam patterns.
Glass Fiber Optics
Ø0.08 Ø0.08 Ø0.08
Sensing distance, Sna Beam Catalog
Type
2.2 2.2 2.2 (max.) standard w/ XUFZ01 lenses Diameter Number
120
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN Plastic and XUFS Glass Fiber Optics
XUFN Plastic and XUFS Glass Fiber Optics
Specifications
Fiber optic type XUFN XUFS
Temperature -14° F to 140° F (-25° to 60° C) -40° F to 356° F (-40° to 180° C)
XUFZ02
Vibration 7 G, 1.5 mm amplitude
Shock 30 G, for 11 ms
core PMMA glass
Materials
jacket PE (polyethylene) stainless steel
Photoelectric Sensors
0.04" (1 mm) OD 0.39" (10 mm) –
Minimum bend radius
XUFZ01 0.08" (2.2 mm) OD 1.0" (25 mm) 3.5" (90 mm)
Accessories
Description Catalog Number
Lenses (pair) for standard threaded tips x10 Magnification t XUFZ01
fois
11 eule once
F-Z e s
XU u un hole
90° mirrors (pair) for standard threaded tips XUFZ02
† o ch
1 tr e ea
er s
lis e u
Uti leas
P Fiber cable cutter (one is included with each fiber optic cable) XUFZ11
4 mm stainless steel sheathing XUFZ210
6 mm stainless steel sheathing XUFZ310
XUFZ11 t Will improve range approximately 3 to 5 times
150 mm
120 mm 1
100 mm
70 mm
50 mm
2
0 mm
2m 5m 10 m
1 XUFN12301L10
2 XUFN05321L10
XUFZk10
121
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN Fiber Optic Cables for Specific Applications
XUFN Fiber Optic Cables for Specific Applications
M2.6x0.45 Features:
0.47 0.12
12 3
0.79
20 Suited for specific applications which were difficult to tackle in the past.
M8 x 1.25 M4x0.7
Thru-Beam Power
High Focus XUFNkP…
Lens XUFNS S for soft:
XUFN2L…
• Flexible enough for maneuvering tight corners
M2.6x0.45 • Bend radius of 4 mm
0.47 0.12
12 3
Ø0.19
5
0.79
Ø0.16
• Resists chemical aggressions
2000
78.7
4
Ø0.08
2.2 • Ideal for food and beverage, assembly and electronic, semiconductor
Soft Flexibility
XUFNkS… XUFNL L for lens:
3.93
100
Ø0.08
2.2
• Integrated focusing lens for precise “spot” sensing
Teflon Coated • Senses longer distances
XUFNkT…
• Convergent beam types sense to three different ranges
XUFN5L02…
XUFN5L01… XUFN5L03…
122
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN Fiber Optic Cables for Specific Applications
XUFN Fiber Optic Cables for Specific Applications
Photoelectric Sensors
a Nominal sensing distance. Recommended usable distance is x0.8 of the nominal sensing distance. This will cover variances in
temperature, supply voltage and manufacturing tolerances.
XUFZ13, XUFZ03
Separate Tips and Mounting Brackets (pair) for un-terminated cables – Thru-Beam mode
Sensing Distance a
Mounting 1.4 mm beam Catalog Number
1 mm beam Diameter
Diameter
Axial 3.94" (100 mm) 5.91" (150 mm) XUFZ13
Non-Magnified Frontal 2.76" (70 mm) 3.94" (100 mm) XUFZ14
Side 2.76" (70 mm) 3.94" (100 mm) XUFZ15
XUFZ14, XUFZ04 Axial 31.50" (800 mm) 23.62" (600 mm) XUFZ03
Magnified Frontal 23.62" (600 mm) 15.75" (400 mm) XUFZ04
Side 23.62" (600 mm) 15.75" (400 mm) XUFZ05
a Distance is at 2m cable length
+ For other cable length:
5 m cable – apply a reduction factor of 0.70 x Sn
10 m cable – apply a reduction factor of 0.50 x Sn
20 m cable – apply a reduction factor of 0.30 x Sn
200 mm
1
150 mm
120 mm
100 mm
2
50 mm
0 mm
4 m 10 m 20 m 30 m 40 m
1 XUFZ911, 921
2 XUFZ910, 920
L = 59.0 Ø0.08
1500 2.2
0.7
Ø0.08 18
2.2
M0.11x0.02 8 head, threaded 1.48" (38 mm) – 16 x 0.01" (0.265 mm) 0.09" (2.2 mm) XUFN02801
3x0.5 a Nominal sensing distance. Recommended usable distance is x0.8 of the nominal sensing distance. This will cover variances in
temperature, supply voltage and manufacturing tolerances.
XUFN02801
123
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Classic XUD and XUD PLUS Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
XUD and XUD PLUS Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics
Features
XUD Amplifiers
• Miniature DIN rail or lateral mounting
• Selectable Light/Dark
• 2 potentiometer adjustments (coarse, fine)
Photoelectric Sensors
n s – L im ite d P ro d u c t XUD Amplifiers for XUFN Plastic and XUFS glass fiber optics
Applicatio
related to sensitivity adjustment Amplifiers – DC models
Sensing distance
Voltage rangea Operating Catalog
Availability
(%) Circuit Type Output Mode Load Current
Max. Frequency Number
100
1 6.6’ (2 m) cable
80
PNP Light/dark 10-30 V 100 mA 500 Hz XUDH003537
60 NPN Light/dark 10-30 V 100 mA 500 Hz XUDJ003537
40
2 Connector – nano style c
20 PNP Light/dark 10-30 V 100 mA 500 Hz XUDH003537S
NPN Light/dark 10-30 V 100 mA 500 Hz XUDJ003537S
0
0 0.25 0.5 0.75 1 N
N: Number of turns on potentiometer P1
1 Potentiometer P2 at maximum XUD PLUS Universal Amplifiers
2 Potentiometer P2 at minimum
.2 meters (7.8") max sensing ranget in Thru-beam mode
.7 meters (2.8") max sensing ranget in Diffuse mode
Voltage range Operating Catalog
Circuit Type Output Mode Load Current
Max. Frequency Number
Verification of correct operation
Cable – 2 meter
Intensity of beam received
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003937
NPN Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDJ003937
1.2 Connector – nano style c
1
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003937S
0.8
NPN Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDJ003937S
Remote potentiometer
Red LED
PNP Light/dark 10-30 Vdc 100 mA 1000 Hz or 4000 Hz XUDH003997S
Green LED
t When used with standard 1mm diameter plastic fiber optics
Optimum + a Including ripple
– alignment c See p. 518 for matching connector cables
LED off
LED on
124
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Classic XUD and XUD PLUS Amplifiers, DC
For XUFN Plastic and XUFS Glass Fiber Optics
XUD and XUD PLUS Amplifiers, DC / For XUFN Plastic and XUFS Glass Fiber Optics
Photoelectric Sensors
H Shock 50 G, for 11 ms
Sourcing BU - Cable 4 #24 AWG, PVC
Electrical
40 mA
Power supply current
BN + < 35 mA for XUD PLUS
BK 1.5 Vdc
Light Mode: Voltage drop across switch
Connect to + <1.8 Vdc for XUD PLUS
NPN
OG Short circuit protection Yes
J Dark Mode: Overload protection Yes
Connect to -
Sinking BU - Reverse polarity protection Yes
On delay 1 ms 500 ms (XUD Plus) t
Off delay 1 ms 500 ms (XUD Plus) t
Power up delay 30 ms
Wavelength 660 nm (red)
Connector Version
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
Light + ®
2 (WH) (BK) t Quick response mode available, 120 ms. Sn is cut in half in quick response mode.
(BN) 1 +
3 - (BU)
n s – L im ite d P ro d u c t
Applicatio
Availability
XUDH0039975
Remote Potentiometer
1 +
2 R -
3
12 V, R = 200 k½
24 V, R = 50 k½
Connector Version
Gain
Control 2 Output
4
1 3
+ –
125
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
XUV Sensors with Separate Optical Heads
The XUV series of separate optical sensing heads and amplifiers provides maximum flexibility
in difficult applications.
Features:
M 18 x 1 Thru beam M 18 x 1 -- Reflex • Thru-beam retro-reflex and proximity diffuse in several housing styles:
Cylindrical – threaded or clip-on for easy replacement
• Extra flat for hard to access places, i.e. small conveyers
Photoelectric Sensors
126
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Technical Data
XUV Sensors with Separate Optical Heads / Technical Data
Photoelectric Sensors
Degree of protection
k NEMA Type 1, 4, 13 1, 5 1, 4, 6, 6P, 13
k IEC Type IP66 IP50 IP67
Cable 0.08 x 0.16" (2.2 x 4 mm) Cable dia. 0.07" (1.8 mm) Cable dia. 0.07" (1.8 mm)
oval section
Connections Length: 19.7’ (6 m) Length: 6.5’ (2 m) Length: 6.5’ (2 m)
Cross section 0.01"2 (0.3 mm2 ) Cross section 0.01"2 (0.3 mm2 ) Cross section 0.01"2 (0.3 mm2 )
Shielded (AWG 22) (AWG 22) (AWG 22)
Material Case: ABS/PC; Cable: PVC
880 nm 880 nm 880 nm Green 565 nm 565 nm
Wavelength
Red 660 nm 660 nm
Mechanical Characteristics
Retroreflective Diffuse Convergent
Threaded Clip-on Extra flat Threaded 20 mm 10 mm
Operation from -13°F to +131°F (-25 to +55°C).
Temperature range
Storage from -22°F to =158°F (-30 to +70°C)
Resistance to vibration 7G amplitude ± 0.6" (1.5 mm) F = 10 to 55 Hz
Resistance to shock 50G, 3 axes, 3 times
Degree of protection
NEMA Type 1, 4, 13 1, 5 1, 4, 13 1, 5
IEC Type IP66 IP50 IP66 IP50
Cable 0.08 x 0.16" (2.2 x 4 mm)
oval section Cable dia. 0.07" (1.8 mm) Cable dia. 0.07" (1.8 mm)
Length: 13’ (4 m) Length: 6.5’ (2 m) Length 6.5’ (2 m)
Connections
Cross section 0.01"2 (0.3 mm2) Cross section 0.01"2 (0.3 mm2) Cross section 0.01"2 (0.3 mm2)
shielded (AWG 22) (AWG 22)
(AWG 22)
Material Case: ABS/PC; Cable: PVC
Wavelength 880 nm 880 nm 660 nm 660 nm
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
®
127
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifiers, DC
XUV Sensors with Separate Optical Heads / Amplifiers, DC
The XUV series of amplifiers designed for use with XUV optical sensing heads provide
maximum flexibility in difficult applications. Features include:
• DIN rail mounting
• Light/Dark programmable
• 3-LED alignment system
• Gating (synchro) input for each channel (except XUVF)
Photoelectric Sensors
XUVF
XUVF • AC single and dual channel, relay output
• Screw terminals and power supply (12 Vdc)
• Fixed time (40 ms) pulse stretcher XUVF – selectable ON/OFF
DC Amplifiers
Operating
Test Synchro Catalog
Output Frequency
Output Input Number
Max.
PNP 500 Hz/2500 Hz Yes Yes XUVH003530
NPN 500 Hz/2500 Hz Yes Yes XUVJ003530
AC Amplifiers
Operating
No. of Test Synchro Catalog
Frequency
Channels Output Input Number
Max.
1 50 Hz – – XUVF000510
2 50 Hz – Yes XUVF000511
For optical heads, see Page 126.
128
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data
Photoelectric Sensors
Shock resistance 30 G
4.5 mm dia. (0.18") Length 2 m (6.6") Terminals 1-8: 16-20 AWG
Wiring
#22 AWG (0.2 mm2) Terminals 9-29: 20-24 AWG
Plastic ABS Plastic ABS
Housing material
Cable PVC Cable PVC
Voltage range (max.) 10 - 30 Vdc including ripple 90 - 264 Vac
Output current (max.) 100 mA 1 A (resistive load)
Short-circuit/overload protection Standard –
Relay output voltage (max.) – 250 Vac, 30 Vdc
Power supply current (no load) 45 mA 30 mA 80 mA
Voltage drop (max.) 1.5 V –
Operating frequency (max.) 500 Hz 2500 Hz 50 Hz 50 Hz
On/Off delay 1 ms 0.2 ms 10 ms 10 ms
Power up delay 1 ms 0.2 ms 10 ms 10 ms
Pulse stretcher (monostable) delay 40 ms 40 ms 40 ms
Test input voltage (max.) 1.5 V @ 1 mA – –
Test output current (max.) 50 mA – –
Radio frequency immunity (RFI) IEC 61000-4-3, L3a (10 V per meter)
DC: IEC 61000-4-2, L2a (4 kV)
Electrostatic discharges
Protective Circuitry AC: IEC 61000-4-2, L3a (8 kV)
Fast transients (motor start/stop interference) IEC 61000-4-4, L3a (1 kV)
Impulse voltages (lightning, etc.) IEC 60947-5-2, L3a (2.5 kV)
E164869 LR44087
Agency Listings CCN NRKH Class 3211 03
®
Replacement Parts
Description Catalog Number
Protective cover for DC amplifiers XUVZ02
129
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data
DC Amplifier XUVH XUVJ Test input (Beam break) Variation of sensing distance
PNP output NPN output Brown + Depending on the sensitivity adjustment
PNP
Synchro MSD Purple sensing dist. (%) P2 (Fine) Max.
E
W 100
Grey H Gating sensor BN LOAD
J Blue -
80
BN BK
H LOAD
BK BU Normal = Emitter ON 60
LOAD
BU NPN Brown + 40 P2 (Fine) Min.
Photoelectric Sensors
Grey
W MSD LOAD Synchro Purple 20
E
J Gating sensor 0
Blue -
0 0.25 0.5 0.75 1
Number of turns of potentiometer P1
Test = Emitter OFF
Marginal Detection LED Marginal Detection Signal (MDS) Optical head wire stripping dimensions
Excess gain optical axis .27 .15
Red LED
7 4
Output t t
1.2 .19 .59
1 MDS
5 15
0.8
State 0 : output off
State 1 : output on
Red LED
t = 40 ms*
Green LED * time delay to avoid nuisance signals
Optimum
alignment
angle
LED off LED on Dual Dimensions inches
mm
3 Reception (white)
L COARSE H L FINE H
L L 0 T 4 Rec. shield
2 UNST.
4
3
5 1 Response time selector switch:
3 6 H = quick response time 4
L = standard response time
2 Light/dark switching selector switch: 1
D = dark switching 2
L = light switching
3 Time delay selector switch:
1 Plastic screwdriver (supplied) 1 = ON
2 Potentiometer P2 (fine adjustment) 0 = OFF
3 Potentiometer P1 (coarse adjustment)
4 White wire function selector switch:
4 Red LED A = Test output
5 Green LED T = Test input
6 Yellow LED
130
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Sensors with Separate Optical Heads
Amplifier Technical Data
XUV Sensors with Separate Optical Heads / Amplifier Technical Data
AC wiring diagrams
Photoelectric Sensors
13 Receiver (white wire)
15 Receiver (shielded cable)
Potentiometers
17 Emitter shield
A
19 Emitter (red wire)
Switches LED Indicators
1 2
1 2 3 1 Power supply (green)
LED indicators
2 Unstable (red)
3 Output (yellow)
2 4 6 8
Potentiometers
Terminals A Sensitivity adjustment
Switches
1 Light/Dark
131
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUK Sub-compact Photoelectric Sensors
Transparent Detection with Timer – DC
XUK SubCompact Photoelectric Sensors / Transparent Detection with timer - DC
Features:
• For detection of PVC, PET and glass targets at a high rate of speed
• Easy set up with a self-teaching feature, enabled by the press of a button
• Alarm output warns of marginal signal
• Time delay (perfect for avoiding jamming on bottling line) adjustment by potentiometer
Photoelectric Sensors
.19 2xØ4
5
1.57 Recommended mounting distances
40 max. 4.9' (1.5 m)
min. 0
1.57
40
1.34
1.57
40
34
10° Ø4,5
2.30
58
1.57
1.97 40
50
.79
20
.71 .86
18 22
58
18
.59
15
Ø6 .51
13
Ø6x13
.47 .19
12 5
2.56
65
3.23
82
3.15
80
132
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUK Sub-compact Photoelectric Sensors
Transparent Detection with Timer – DC
XUK SubCompact Photoelectric Sensors / Transparent Detection with Timer - DC
Wiring Specifications
Mechanical
Operation 13 to 131° F (-25 to 55° C)
Temperature Range
PNP Yellow on Storage 40 to 158° F (-40 to 70° C)
NEMA Type 3,4,4X,6,12,13
Enclosure Rating
BN + IEC Type IP67 conforming to IEC 60529
Vibration 7G amplitude + 1.5 mm (f=10 to 55 Hz)
BK
– Shock Resistance 30G for 11 ms conforming to 68-2-27
BU Connection 6 mm dia. PVC cable with 0.34 mm wire
Photoelectric Sensors
Tightening Torque (Maximum) 5 N•m
Case PC/ABS
Enclosure Material Lens PMMA
NPN Cable PvR
Yellow on
Electrical
BN + Voltage Limit (Including Ripple) 10 - 30 V
Voltage Drop (Across Switch, Closed State) 2V
BK
– Current Consumption (Maximum) (No Load) 35 mA
BU Yellow Output LED Yes
Red Stability LED Yes
Power-up Delay (Maximum) 80 ms
On Delay (Maximum) 0.3 ms
Off Delay (Maximum) 0.3 ms
Short Circuit Protection Yes
Protective Circuitry Overload Protection Yes
Reverse Polarity Protection Yes
Agency Listings
®
1 Timing Function
A 2 1. Light on - Dark on
3 2. Timer on - Timer off
3. Delay / One shot
4 4. On Delay / Off Delay
7 T 8 5. PNP or NPN
5
B T = Time delay 6. Yellow LED - output on and learning mode
7. Red LED - alignment and alarm
3.DL 1 SHOT 8. Self teaching button (SET)
4.ON OFF
5. PNP NPN
Time Delay No time delay Normal time delay (T) time Normal time delay (T) time Monostable time delay (T)
delay on trip "OFF-DELAY" delay on reset "OFF-DELAY"
Switch Positions
1 1 1 1
2 2 2 2
3 3 3 3
4 4 4 4
Receiver state Beam made
Beam broken
T T T T T T T
Light switching Relay on
1 Relay off
T T T T T T T
Dark switching Relay on
1 Relay off
133
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUM Miniature, Color Mark Detector
DC
XUM Miniature, Color Mark Detector / DC
High performance, self contained medium range miniature photoelectric sensors for color mark
detection.
Features:
• Very small dimensions 1.4" x 0.87" x 0.39" (35.5 x 22.1 x 9.9mm)
• Marginal Detection Signal (MDS) provided for alarm output and alignment help.
Photoelectric Sensors
optical
axis
recommended
Minimum detectable 16" operating zone
width of mark: 1mm
A B
134
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUM Miniature, Color Mark Detector
DC
XUM Miniature, Color Mark Detector / DC
Wiring Specifications
Mechanical
Temperature range -13° F to 131° F (-25° C to 55° C)
PNP output NEMA Type 1, 3, 4, 6, 6P, 12, 13
Enclosure rating
Prog. + Light IEC Type IP67 conforming to IEC 60529
Enclosure material Housing: ABS/PC; Lens: PMMA,PC; Cable: PVC
OG - Dark
BN
Vibration resistance 7 G amplitude ± 1.5mm (f= 10 to 55 Hz)
H BK Shock resistance 50 G 3 axes, 3 times
Photoelectric Sensors
LOAD
BU Wiring 6’ cable, 0.18" dia., 3 x #24 AWG
W MDS LOAD
Electrical
Voltage limits (including ripple) 10-30 Vdc
Load current max. 100 mA, protected against overload and short circuit
NPN output Voltage drop “closed” state 1.5 V
MDS No load current consumption 35 mA
W LOAD
Test output current max. 50 mA
BN Test input voltage max. 1.5 V @ 1 mA max.
J BK LOAD
Purple
a L indicates level number.
Accessories
Blue -
Description Sensing Distance Catalog Number
Thru-beam aperture (1) 0.5 mm and (1) 1 mm 4.5 cm (1.78") XUMZ01
Beam broken Thru-beam aperture (1) 1.5 mm and (1) 2 mm 4.5 cm (1.78") XUMZ03
E Brown +
Purple
Blue -
135
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUMW Liquid Detection Sensor
DC
XUMW Liquid Detection Sensor / DC
Features:
• Reliable detection of transparent or color liquids
• Able to detect liquid in thick containers
• Ability to control container filling
Circuit Voltage Connection Load Current Operating Frequency
Output Mode Catalog Number
Photoelectric Sensors
Application Examples
Dimensions
d
0.06
41 5.6 13
0.45
11.5
0.9
23
1.2
32
d
0.4
(3)
10
0.1
2.5
1
0.8 2
40
20
60
0.12
3
Intensity of
beam 80
100
500 1000 1500 1700
Dual Dimensions inches 1100 1450
mm Transmission wavelength (nm)
136
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUMW Liquid Detection Sensor
DC
XUMW Liquid Detection Sensor / DC
Specifications
Wiring Mechanical
200 mm for optimum liquid detection
Emitter Nominal Sensing Range (Sn)
10 m as standard thru-beam
Operation 32 to +104 ° F (0 to +40 ° C)
Temperature Range
Storage 24 to +122 ° F(-5 to +50 ° C)
Enclosure Rating IEC Type IP65 conforming to IEC60529
Photoelectric Sensors
Black PNP Output Black PNP Output Vibration 25 gn, amplitude +/- 2mm (f=10 to 55 Hz)
White NPN Output White NPN Output Shock Resistance 30 gn for 11ms conforming to IEC 60068-2-27
WH WH Output Yellow
LED indicator
Signal Stability Green
Case PBT
Enclosure material
Lens Polycarbonate
N.C. N.O.
(no object present) (no object present) Connection 2 m (6.6’) cable, 4 mm O.D. 2, 3 conductor x0.2 mm2
Light emission Infrared (1450 nm)
Electrical
Voltage Range 12-24 Vdc
Voltage limit (including ripple) 10-30 Vdc
Operating Frequency 1000 Hz
Current consumption (no load) 45 mA
Voltage Drop (max.) 2V
Power-up delay (max.) 50 ms
On-delay (max.) 0.5 ms
Off-delay (max.) 0.5 ms
Agency Listings
50
Output On
20 Yellow LED Off
10 Stability On
Green LED Off
5
2
1
0,1 0,2 0,5 1 2 5 10 20 50 100
D (m)
1,15
0,75
1 2 3 4
LED
1 Yellow output LED
Time 2 Green stability LED
ON Potentiometer
OFF 3 Sensitivity adjustment switch
4 Light / Dark switching programming
ON
OFF
ON
OFF
137
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUR Color Mark Registration, DC
XUR Color Mark Registration, DC
Features:
• 20 turn sensitivity/potentiometer
• Light/dark selectable
• Red or green lens option, selectable via adjustment screw
• Standard Micro style connector receptacle t
Photoelectric Sensors
Threshold
adjustment D
L Output state
PUT
OUT LED
Red/green
An angle of 5 to 10° from vertical is recommended transmission
for reflective or transparent surfaces. (switch fitted with LEDs to assist
protective cover) adjustment
Maximum vertical inclination: 20°
A
.20
5
.06
1.5
C
A B C
XURK 9 5 1.5
XURK + XURZ01 18 7 2
XURK + XURZ02 7 4 1
138
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUR Color Mark Registration, DC
XUR Color Mark Registration, DC
Wiring Specifications
Connector Mechanical
1 (+) Operation 14° to 131° F (-10° to 55° C)
Temperature range
Storage -4° to 158° F (-20° to 70° C)
2 4
Output Enclosure rating IEC Type IP67 conforming to IEC60529 and IP673, NCF 20-010
Vibration 7 G amplitude ±.6 mm conforming to IEC 60068-2-6
3 (–)
Shock resistance 30 G for 11 ms, conforming to IEC 60068-2-7
Photoelectric Sensors
Light mode Case ZAMAC
Enclosure material
Lens Glass
PNP output
Wiring Micro connector
1 + Spot dimensions 1.5 x 5 (min. detectable width 0.5mm)
4
Max. Linear speed of mark 10 ms (for 1 mm wide mark)
3 – Max. Vertical inclination of reader 20°
2
Electrical
Voltage range 12 - 24 Vdc
NPN output
Voltage limit (including ripple) 10 - 30 Vdc
1 + NPN 1.2 V
Voltage drop (across switch, closed state)
4 PNP 2.2 V
3 – Load current (max.) 100 mA
2
Current consumption (max.)(no load) 80 mA
Operating frequency (max.) 1000 Hz
Power-up delay (max.) 100 ms
Dark mode On delay (max.) 50 ms
Off delay (max.) 50 ms
PNP output
Time delay Off delay 20ms
1 +
4 Physical Characteristics
Red 635 nm
3 – Emitter wave length:
Green 565 nm
2
Short circuit protection yes
Protective Circuitry Overload protection yes
NPN output Reverse polarity protection yes
1 +
4
3 –
2
Accessories
Description Catalog Number
Magnifying lens XURZ01
Focusing lens XURZ02
1.10
50
28
3
3.43
40
2.95
75
30
1.64
41.5
20
1.44
36.5
10
0
0 5 10 15 20 25
.16
30 24 15.5 1 XURK z z z z z z z
2 XURZ01
3 XURK XURZ02
Connector Cables (M12 or D suffix) Dual Dimensions inches
mm
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
139
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURK1 Self-Teaching Color Mark Registration, DC
XURK1 Self-Teaching Color Mark Registration, DC
Features:
• Self teaching for memorization of target and precision repeatability
• 0 to 5.5 V analog output, depending on the illumination level of mark
• Magnifying lenses increases sensing distance to 18mm or focuses to 7mm
• Optional straight or 90 ° sensing set up
Photoelectric Sensors
.82
1.56 21
40 .33
8
.94
24
.60
Detection Zone and
M12x1
15 Mark Size (mm)
1.10
1.10 28 a
28
3.20
81
1.08
27 b
1.44 8xM5x6
37 c
.55
14
Ø25
a b c
.23 1.66 .17
6 42 4
2.28 1.22 IN mm IN mm IN mm
58 31
XURK1KSMM12 .35 9 .20 5 .08 2
Vertical Plane
5° < α < 20°
α α
5° 5° An angle of 5 to 10°
from vertical is recommended
for reflective or
transparent surfaces.
Max. vertical
inclination: 20°
140
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURK1 Self-Teaching Color Mark Registration, DC
XURK1 Self-Teaching Color Mark Registration, DC
Wiring Specifications
Mechanical
PNP
9 mm
Nominal sensing range
1 + (7 mm with XURZ01,18 mm with XURZ01
2
Spot dimension 1.5 x 5 mm diameter
R
4 0 to 5.5 V Min. detectable width of mark 0.5 mm
3 – Max. linear speed of mark 10 m/s (for 1 mm mark)
Photoelectric Sensors
Operation: 14° to 131° F (-10° to 55° C)
Temperature range
Storage: -4° to 158° F (-20° to 70° C)
NPN Enclosure rating IEC Type: IP67 conforming to IEC 60529
1 +
Vibration 7 G amplitude + 0.65 mm (f=10 to 55 Hz)
2
Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
4
R 0 to 5.5 V
LED indicator type Red - output, green - learning mode
3 –
Enclosure material Die cast Zinc
Sensitivity Adjustment Automatic, through self-teach function
1 (+) Connection M12, 4 pin connector
Light emission Red or green (automatic selection)
Analog 2 4 Solid State
Output Output Electrical DC models
3 (–) Voltage limits (including ripple) 10 - 30 Vdc
Rated Supply Voltage 12 - 24 V (with reverse polarity protection)
Operating Frequency 10,000 Hz
Analog output 0 - 5.5 V (voltage proportional to light reflected by the object)
Current consumption (max.)(no load) 80 mA
Power-up delay (max.) 100 ms
On delay (max.) 50 µs
Off delay (max.) 50 µs
Timing 20 ms “off delay”
Accessories
Description Catalog Number
Mark magnification lens XURZ01
Mark reduction lens XURZ02
100
90
2 1
80
70 XURZ01
60
50
40
3
30
20
10
XURZ02
0 XURK1KSMM12 Lens
0 5 10 15 20 25
Distance (mm) 1. Green LED, unit in
learning mode
1 XURK1KSMM12 2. Red LED, output state
2 XURK1KSMM12 + XURZ01
3. Learning mode button
3 XURK1KSMM12 + XURZ02 for mark
141
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURU Ultra Violet (UV) Self-Teaching, DC
XURU Ultra Violet (UV) Self-Teaching, DC
Features:
• Detects invisible marks, glues, varnishes, etc.
• For detection of Ultra Violet marks and products containing UV blueing agents, as used for
packaging identification and quality assurance.
• 0 to 7 V analog output, depending on the illumination level of UV mark
• Self Teaching for memorization of target and precision repeatability
Photoelectric Sensors
.33 .82
21 1.22
9 31 a
1.67
42 .94 .23
8xM5x6 6
24
1.56
40
a Ø
IN mm IN mm
1.44 1.10 XURU1KSMM12 .35 9 .20 5
37 28
XURU1KSMM12 + XURZ01 .71 18 .28 7
Dual Dimensions inches
mm XURU1KSMM12 + XURZ02 .28 7 .12 3
Excess Gain Curve
% of signal
100
90
2 1
80 Vertical Plane
70
5° < α < 20°
60
α α
50
An angle of 5 to 10°
40
3 5° 5°
from vertical is recommended
for reflective or
30 transparent surfaces.
20 Max. vertical
inclination: 20°
10
0
0 5 10 15 20 25
Distance (mm)
1 XURU1KSMM12
2 XURU1KSMM12 + XURZ01
3 XURU1KSMM12 + XURZ02
142
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURU Ultra Violet (UV) Self-Teaching, DC
XURU Ultra Violet (UV) Self-Teaching, DC
Wiring Specifications
Mechanical
PNP 9 mm
Nominal sensing range
1 + (7 mm with XURZ01,18 mm with XURZ01)
2 UV spot dimensions 5 mm diameter
R
4 0 to 7 V Operation 14° to 131° F (-10° to 55° C)
3 Temperature range
– Storage -4° to 158° F (-20° to 70° C)
Photoelectric Sensors
NEMA Type 3,4,4X,6,6,12,13
Enclosure rating
IEC Type IP67 conforming to IEC 60529
NPN
1 Vibration 7 G amplitude + 0.6 mm (f=10 to 55 Hz)
+
2 Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
Accessories
Description Catalog Number
Mark magnification lens XURZ01
Mark reduction lens XURZ02
XURZ01
XURZ02
XURU1KSMM12 Lens
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
For additional cable options and lengths see p. 518
143
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XURC Full Color and Fiber Optic Full Color Detectors
XURC Full Color and Fiber Optic Full Color Detectors
Features
• Ideal for applications such as sorting, label detection and multi-color printing
• Self-teaching with adjustable sensitivity for comparing and matching of similar colors
• Three channels with independent outputs
• Selectable response time
Photoelectric Sensors
XURC4
2.60 .40
.21 3.24 .21 .99 66 10
(2)
5 82 5 25
1.45
37 .63
16
.19
1.73
5
.98
44
25
1.18
30 Ø4.4 (3)
(4) .59
15
Dual Dimensions inches (1)
mm
(1) DIN Rail Mounting Accessory (Included)
(2) Locking Latch for Fiber Optic Cables
144
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XURC Full Color and Fiber Optic Full Color Detectors
XURC Full Color and Fiber Optic Full Color Detectors
Wiring Specifications
Mechanical
+ Operation 14° to 122° F (-10° to 50° C) q
PNP BN Temperature Range
Ue: 12 to 24 V PK (Set) Storage -22° to 158° F (-30° to -70° C)
le : 100 mA VT (Sync)
BK (OutA) Enclosure Rating IEC Type IP67 conforming to IEC 60529
WH (Out B) Vibration Amplitude 0.75 mm, f =10-55 Hz (2 hours/each of 3 axes)
GY (Out C) Shock Resistance 50 G (5 shocks/each of 3 axes)
BU –
Photoelectric Sensors
Maximum Operating Humidity 35 to 85% RH q
XURC•PPML2 at 40 mm at 50 mm at 60 mm
Spot diameter
4 mm 6 mm 8 mm
Case Aluminum
+ Enclosure Material Lens Glass
NPN BN BK (OutA)
Ue: 12 to 24 V WH (Out B) Cover Polyarylate
le : 100 mA GY (Out C) Wiring 24 AWG (0.2 mm2), Cable: vinyl rubber sleeve
PK (Set)
VT (Sync) Electrical
BU Voltage Range 12 - 24 Vdc
–
Voltage Limit (Including Ripple) 10 - 30 Vdc
XURC•NPML2
Voltage Drop (Across Switch, Closed State) 1.5 V
Load Current (Maximum) 100 mA
Current Consumption (Maximum) (No Load) 150 mA
Wire Definitions Power-up Delay (Maximum) 100 ms
Output time delay, internal synchronization mode Output time delay, external synchronization mode
Object Object
detected detected
ON Ext. synchro
Output signal
OFF 40 ms 40 ms
ON
Output
OFF 40 ms 40 ms
145
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Advanced Label Detection Fork, DC
XUV Advanced Label Detection Fork, DC
Features:
• Detects opaque colors on transparent background
• Self teaches to memorize label for accurate detection
• Adjustable from straight to 90 ° connection
• Two LEDs indicate three conditions: yellow - output, green - ready, red - error
Photoelectric Sensors
Thru-beam - 2mm (0.079") Nominal Sensing Range – Visible red/green light emission
PNP/NPN Light/Dark 12 - 24 Vdc 100 mA 10K Hz XUVK0252VS
Function table
Output state (PNP or NPN) indicator (illuminated when detector output is ON)
Thru-beam system
Mode
Absence of label in the beam Presence of label in the beam
Light switching
Dark switching
1 Applications: the infra-red transmission beam detector XUV-K0252S is suitable for the detection of all types of opaque legends; the red/
green transmission beam detector XUV-K0252VS is suitable for the detection of all types of opaque and different colors.
2 The detector incorporates “self-teaching” setting: the light or dark switching function is selected when performing the first stage of the
“self-teaching” setting procedure during set-up of the detector (see “self-teaching” setting procedure, below).
146
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Advanced Label Detection Fork, DC
XUV Advanced Label Detection Fork, DC
.08 Specifications
2
.35 .35 .79 Mechanical
.30
7.5
9 9 20
Operation 32° to 131° F (0° to 55° C)
Temperature range
Storage -4° to 158° F (-20° to 70° C)
Enclosure rating IEC Type IP65 conforming to IEC 60068-2-27
1 2 Vibration 7 G amplitude + 1 mm (f = 10 to 42 Hz) conforming to IEC 60068-2-6
1.97
50
Photoelectric Sensors
Case Zinc alloy
3.54
90
Enclosure material
3.83
97.5
Lens Glass
Ø0.17 3
Wiring Female NANO connector
Ø4.25
4 Electrical
Voltage range 12 - 24 Vdc
1.02
.71
18
26
9 9 20 Protective Circuitry
Reverse polarity
yes
protection
1 2
1.97
50
3.54
90
Ø0.17 3
Ø4.25
4
M8
1.02
.71
18
26
.31
8
.71 .16
18 4
1.02 .30
26 7.5
Connector
NPN output 2 4 PNP output
1 3
+ –
147
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Self-Contained Fork Type (30 mm)
Economy, DC
XUV Self-Contained Fork Type (30 mm) / Economy, DC
Features:
• Self contained electronics eliminates the need for a separate amplifier
• Ideal for detection of small parts at fast speeds
• 360° LED output indicator
• ABS enclosure
Photoelectric Sensors
• CE mark
Voltage Range Load Current Operating Catalog
Circuit Type Output Mode Connection
Max Max Frequency Number
Thru-Beam – 30mm (1.18") Nominal Sensing Range
PNP Dark 19-38 Vdc 150 mA 1000 Hz 2m (6.6’) cable XUVH0312
NPN Dark 19-38 Vdc 150 mA 1000 Hz 2m (6.6’) cable XUVJ0312
Function Table
Thru-Beam System
Function
No object present in the beam Object present in the beam
Detection Curve
.06 (± .01) in.
1.5 (± 0.3) mm
148
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUV Self-Contained Fork Type (30 mm)
Economy, DC
XUV Self-Contained Fork Type (30 mm) / Economy, DC
Wiring Specifications
Mechanical
Dark mode (no object present) Operating 23° to 131° F (-5° to 55° C)
Temperature Range
Storage - 4° to 158° F (- 20° to 70° C)
PNP output Enclosure Rating IEC Type IP54 conforming to IEC 60529
Case PC/ABS
BN Enclosure Material Lens PMMA
Cable PVC
Photoelectric Sensors
BK
Vibration resistance (IEC 60068-2-6) 7 gn, amplitude ± 1mm (f = 42 Hz to 150 Hz)
BU
Shock resistance (IEC 60068-2-27) 30 gn, duration 11 ms
LED indicator type 360° ring LED: shows output status
Connection Cable 5 mm diameter cable, 3 x 0.5 mm2
Electrical
Voltage Limits (including ripple) 19 – 38 Vdc
Voltage Drop (across switch) closed state max. 1.5 V
Current consumption (no load) Max. 20 mA
Load Current Max. 150 mA
Max. Operating frequency 1000 Hz.
On delay max. 500 µs
Off delay max 500 µs
Power-up delay max 30 ms
Short circuit protection Yes
Overload protection Yes
Reverse polarity protection Yes
Physical Characteristics
Ambient light immunity 1000 Lux.
Emitter wave length 880 nm
2.28 = .55 =
58 14
1.18
30
(1)
149
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUVF Dynamic Fork Type – DC
XUVF Dynamic Fork Type - DC
XUVF sensors detect the dynamic flow of all types of objects (both metal or plastic, and of any
color or shape)
Fork body detects moving targets for use in applications such as:
• Parts ejection, as in air compression transfer of parts
• Counting parts traveling down a chute
Photoelectric Sensors
Features:
• Detects targets falling at a minimum of 10 cm per second, maximum 15 meters per second
• Off-delay (reset) timer function: 0 to 5 seconds
• Sensitivity and timing adjustment by separate potentiometers
• Green output LED and red alarm LED for clear indications
• Sturdy aluminum body and M8 (Nano) connector
Voltage Load Operating
Circuit Output Catalog
Range Current Frequency
Type Type Number
Max. Max. Max.
Thru Beam - 30mm x 30mm Fork – Minimum Target 2mm – Nano Style Connector
PNP/NPN Light/Dark 18 - 30 Vdc 100 mA 500 Hz XUVF30M8
Thru Beam - 60mm x60mm Fork – Minimum Target 2mm – Nano Style Connector
PNP/NPN Light/Dark 18 - 30 Vdc 100 mA 500 Hz XUVF60M8
5.16
131
Dual Dimensions inches .63
mm
2.36 16
60
4.25
108
1.18 .63
30 16
2.75
(R) (R) (E) 70
(E) 1.41
36
.13 .13
3.5 3.5
M8 M8
.86 2xØ4.2 .86 2xØ4.2
22 22
.59
15
Sensitivity
.59 T imer off
15
delay 0 to 5s.
3.38
Sensitivity 86
T imer off
1.97 LEDs
50 delay 0 to 5s.
.45 .45 E=Emitter
11.6 LEDs 11.6 R=Receiver
XUVF30M8 XUVF60M8
150
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUVF Dynamic Fork Type – DC
XUVF Dynamic Fork Type - DC
Wiring Specifications
Connector Mechanical
Alarm Output Operation 32° to 140° F (0° to 60° C)
Temperature range
2 4 Storage -4° to 176° F (-20° to 80° C)
1 (+) 3 (–) Enclosure rating IEC Type IP65 conforming to IEC 60529
Vibration 25 G amplitude ± 2 mm (f =10 to 55 Hz)
Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
Photoelectric Sensors
PNP 1 +
Case Aluminum
4 Enclosure material
Output Lenses Polycarbonate
2 Alarm Connection M8 (Nano Style 4 Pin DC) connector
3 – Minimum target size 2mm diameter
Emission type Infrared
Sunlight: 4000 lux
Ambient Immunity (max)
NPN 1 + Incandescent: 400 lux
4 Output Electrical
2 Alarm Voltage limits (including ripple) 18–30 Vdc (reverse polarity protected)
3 – Voltage drop (across switch, closed state) 2V
Current consumption (max.)(no load) 120 mA
Power-up delay (max.) 100 ms
On delay (max.) 1 ms
Off delay (max.) 1 ms
Timing Off-delay (reset): 0 to 5 seconds
Two LED Indicators Output, alarm, supply failure and short circuit
Minimum Target Speed 10 cm/s @ 2 mm Dia.
Maximum Target Speed 15 cm/s @ 2 mm Dia.
Output
on GR
Alarm
on RD
Detection of parts passing through fork: green LED indicates output. If parts are lodged inside fork, red LED indicates alarm.
151
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUVF Dynamic Window Type – DC
XUVF Dynamic Window Type - DC
XUVF sensors detect the dynamic flow of all types of objects (both metal and plastic, and of
any color or shape).
Window body detects moving targets for use in applications such as:
• Parts ejection, as in air compression transfer of parts
• Counting parts traveling down a chute
Photoelectric Sensors
Features:
• Detects targets falling at a minimum of 10 cm per second, maximum 15 meters per second
• Off-delay (reset) timer function: 0 to 5 seconds
• Sensitivity and timing adjustment by separate potentiometers
• Green output LED and red alarm LED for clear indications
• Sturdy aluminum body and M12 (Micro) connector
Voltage Load Operating
Circuit Output Catalog
Range Current Frequency
Type Type Number
Max. Max. Max.
Thru Beam - 200mm x 120mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF120M12
Thru Beam - 200mm x 180mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF180M12
Thru Beam - 200mm x 250mm Window – Minimum Target 4mm – Micro Style Connector
PNP/NPN Light/Dark 18–30 Vdc 100 mA 500 Hz XUVF250M12
Sensitivity adjustment
potentiometer
.86
22
Dimensions
a a1
Dual Dimensions inches
IN mm IN mm mm
152
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUVF Dynamic Window Type – DC
XUVF Dynamic Window Type - DC
Wiring Specifications
Connector Mechanical
1 ( +) Temperature range Operation 32° to 140° F (0° to 60° C)
Photoelectric Sensors
PNP 1 + Case Aluminum
Enclosure material
4 Output Lenses Polycarbonate
2 Connection M12 Micro Style 4 pin connector
Alarm
3 Minimum target size 4 mm diameter
–
Emission type Infrared
Sunlight: 4000 lux
Ambient Immunity (max)
NPN 1 + Incandescent: 400 lux
4 Output Electrical
Voltage limits (including ripple) 18–30 Vdc (reverse polarity protected)
2 Alarm
Voltage drop (across switch, closed state) 2V
3 –
Current consumption (max.)(no load) 400 mA
Power-up delay (max.) 100 ms
On delay (max.) 1 ms
Off delay (max.) 1 ms
Timing Off-delay (reset): 0 to 5 seconds
LED Indicators Output, alarm, supply failure and short circuit
Minimum Target Speed 10 cm/s @ 4 mm Dia.
Maximum Target Speed 15 cm/s @ 4 mm Dia.
Detection of parts passing through window: green LED indicates output. If parts are lodged inside window, red LED indicates alarm,
but sensing operation is not affected.
153
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUZ Power Supply/Converter, AC to DC
ZUZ Power Supply/Converter, AC to DC
Features:
• AC supply, DC output
• Two channel amplifier, for PNP Solid State
• Three LED indicators: Power, Output 1, Output 2
• N.O. and N.C. output per channel
Photoelectric Sensors
.29
7.3
91.5
2.7 1.77
68.5 45
+
.59
15
1.51
1.44
36.5
38.5
– .75 .75
3.09
78.5
63.5
2.5
19.2 19.2
.94
1.77
24
45
.78
4.5
Dual Dimensions inches
mm
154
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUZ Power Supply/Converter, AC to DC
XUZ Power Supply/Converter, AC to DC
Specifications
Mechanical
Storage -22° F to 158° F (-30° C to 70° C)
Temperature range
Operation 14° F to 131° F (-10° C to 55° C)
Enclosure rating IEC Type IP20 conforming to IEC 60529
Vibration 7 G +/- 1.5 mm F: 10-55 Hz
Shock resistance 10 G at 3 axes / 3 times
Photoelectric Sensors
Supply: green
LED indicator type Output - channel 1: yellow
Output - channel 2: yellow
Enclosure material ABS
Electrical
Voltage range 100-240 Vac
Voltage on Relay Output 264 Vac, 30 Vdc
Current consumption (max.)(no load) 10 mA
Operating frequency (max.) 50 Hz
Power-up delay (max.) 20 ms
On delay (max.) .1 ms
Time delay 40 ms (fixed)
Relay load current 1A
Terminals
1-2 Supply AC
3 N.C. contact output, channel 1
9 11 13 15 17 19 4 N.C. contact output, channel 2
5 Common output, channel 1
6 Common output, channel 2
7 N.O. contact output, channel 1
8 N.O. contact output, channel 2
9 Supply DC 12 V (–) for detector controlling channel 1
11 Connection terminal for output of detector controlling channel 1
13 Supply DC 12 V (+) for detector controlling channel 1
D1 D2 D3 15 Supply DC 12 V (–) for detector controlling channel 2
17 Connection terminal for output of detector controlling channel 2
19 Supply DC 12 V (+) for detector controlling channel 2
LED indicators
2 4 6 8
D1 Supply (green)
D2 Output, channel 1 (yellow)
D3 Output, channel 2 (yellow)
1 3 5 7
Connections
BN +
11 13 15 17 19
OUT2 OUT1
PNP
8
BK
IN2
BU
5
6
-
BN
+
PNP
3
4
BK
IN1
2
BU
-
9
AC
155
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Reflectors
Specifications
Reflectors / Specifications
0.3" Corner cube reflectors used with retroreflective photoelectric sensors provide a high degree of
reliability since they return the light to its source even if the reflector and the switch are skewed
quite significantly in respect to each other. Corner cube reflectors also have the only reflective
surface that works with polarized photoelectric sensors. The nominal sensing distance for every
retroreflective switch model in this catalog was established using a 3" RF30 reflector. Smaller
3"
reflectors will result in shorter sensing distances. They are used to detect smaller targets
comparable with their dimension. The standard reflectors present a “blind spot” at about 10%
Photoelectric Sensors
of the sensing distance. Special reflectors XUZC24/50 are designed to eliminate this
inconvenience and allow the reflector to come as close as touching the sensor lenses.
RF30
RF30 and RF20 models can be mounted via a bolt. RF10 models can be mounted using a bezel
0.3"
or plate (not provided) or using its own adhesive tape. Rectangular shaped reflectors increase
sensing precision. They are also easier to mount side-by-side to increase the reflective surface.
Reflective tape can be used for covering unusually shaped targets. It is not a corner cube
reflector. Only Super reflective tape is a corner cube reflector. It can also be used with polarized
2"
retroreflective sensors.
Reflectors
RF20 Description Reflectivity Temperature Rating Catalog Number
3" diameter, acrylic lens 4000X 150° F (65° C) RF30
2" diameter, acrylic lens 4000X 150° F (65° C) RF20
1" diameter, acrylic lens 4000X 150° F (65° C) RF10
1"
2.0
59
1.85
47
2.83
72
2.36
2.71
60
69
100 2.8
8 73 XUZB• XUZC••
XUZC100 XUZD15 4xØ4.5 4xR2.25 .31 .13
8 3.5 .31
XUZC50 8
156
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Accessories
Accessories
Covers
Protective Cover XUJ, XUE XUZD25
Potentiometer Cover XUJ XUJZ01
XUJZ01 XUZD15
Reflector Cover XUZC XUZD15
Transparent Cover XUD XUDZ02
XUZD25
Photoelectric Sensors
Transparent Cover XUV XUVZ02
Alignment Tool XUJ, XUE (Thru-beam) XUZD09
Lens Hood XUE XUZD02
Bottom Entry Conduit Cover (9mm) XUJ XUJZ09
Masks
XUZD09 Mask: 10cm/40cm Range, 0.5mm/1mm Diameter Classic XUM (Thru-beam except XUML) XUMZ01
XUVZ02
Mask: 0.9m/1.5m Range, 1.5mm/2mm Diameter Classic XUM (Thru-beam except XUML) XUMZ03
Mask: 1M Range, 6mm Diameter XUJ (Thru-beam) XUJZ02
Mirrors
90 ° Mirror Adaptor XU 18mm (Retroreflective and Diffuse) XUBZ01
XUDZ02 90 ° Mirror Adaptor XU 18 mm (Thru-beam) XUBZ02
Mounting Hardware
XUZD02 Mounting Bracket (Plastic) XUML•S XUZA46
XULZ41 a
Mounting Bracket (Metal) XUL XULZ43
XULZ43
XUMZ0k Mounting Bracket (Metal) XUJ XUZA41
Adjustable Mounting Bracket (Metal) XUJ XUZA43
XUJZ09 Mounting Bracket (Metal) XUE XUZA44
Mounting Bracket (Metal) XUM XUZA47
XUBZ01 Mounting Bracket (Metal) XUJL, XUJB XUZA49
Mounting Bracket (Metal) XU 18 mm, XUB XUZA118
XUJZ02
Swivel Mounting Bracket (Plastic) XU 18 mm, XUB XUZA218
XUBZ02 Precision adjustment mounting bracket (micro metric precision) XU2 18 mm laser, XUB XUZA318
Mounting Bracket (Plastic) XUA XSAZ108
Mounting Bracket (Plastic) XUA XSZB108
Mounting Bracket (Plastic) XU 18 mm, XUB XSAZ118
Mounting Bracket (Plastic) XU 18 mm, XUB XSZB118
Mounting Nuts (Plastic) XU 18 mm, XUB XSAZ318
Swivel mounting bracket (Plastic) XUC XSZSB30
a See p. 170 for mounting positions of the XULZ41.
XSAZ1•• XSZB1••
XUZA46 XUZA44
XSAZ1kk
XSA a b b1 c d d1 dia d2 dia d3 dia f g g1
Z108 23.5/.92 14.2/.56 16.7/.66 10/.39 8/.31 8.5.33 2/0.7 3/.12 13/.51 16/.63 5/.19
Z118 41/1.61 30/1.18 33/1.3 20/.79 18/.71 18.5/.72 3.9/.15 6/.23 29/1.14 30/1.18 8/.31
Z130 53/2.06 39.5/1.55 42.5/1.67 20/.79 21.5/.85 30./1.2 3.9/.15 5/.19 39/1.53 40/1.57 10/.39
XSZBkkk
XUZA318 XUZA49 XSZ a a1 b b1 b2 dia
B108 19.9/.78 14.5/.57 14/.55 12.5/.49 7.5/.29 8/.31
B118 26/1.02 15.7/.62 22/.86 20.1/.79 11.5/.45 18/.71
B130 39/1.53 21.7/.85 35.5/1.40 31/1.22 18.5/.73 30/1.18
157
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Accessories
Accessories
1.89
48 2x¯7
0.63
=
16
3.46
2.83
88
72
(1)
¯4,2
133.5
6.26
=
101.5
4.0
Photoelectric Sensors
5.87
10¡ 10¡
149
3.15 2.87 5xØ8
73
2.6
80
66
¯4 ¯6 3.59
10¡10¡
91
0.87
XUZD15
0.63
22
0.63
16
16
¯6
= =
3.28 1.73 1.73
83.4 5.04É5.32 44 44
128É135
XUZD25
Ø7
1.06
27
2.75 1.45
9.45 70 37
240
XUZD09 0.10
2.5 Ø18.5
1.38
35
1.69
2.32
43
59
1.10 = =
12.7 28 1.97
(0.50) 50
M30x1 0.59
15
0.039
0.25
1
6.5
0.79 0.90 6.34
20 1.3 23
0.39
= =
(0.25)
10
0.65
16.5
33
27.9
XUZD0• (1.10) 20.3 0.25 0.79
6.5 20
(0.80)
14.2 XUZA118
4x¯4.2 0.27 (0.56)
7 0.39 1.77 Ø18.5
29.2 10 45
=
(1.15)
=
1.57
40
15
1.18
30
28.7 50.8
0.98
=
2.64
25
(1.13)
67
(2.00)
0.19
5
=
2.16
66.7 55
4x¯4.2
(2.62)
0.31 0.94 0.31
0.27
7
8 = 24 = 8
0.25
6.5
= = = 1.18 = XSZSB30
= 1.18 = 30
1.57
1.06
27
19.5
30
0.76
40
1.57 1.65
40 42 15
XUZA43
XUZA218
1.51 Ø
38.3
b
Ød1
b1
b2
0.14
Dual Dimensions inches
2.5 b1
3.5
b
mm a1
f
0.98
(1) a
Ød3
Ød2
= = = =
c G G1 0.16 0.86 0.31
a 4 22 8
XSAZ1kk XSZB
Z118 41/1.61 30/1.18 33/1.3 20/.79 18/.71 18.5/.72 3.9/.15 6/.23 29/1.14 30/1.18 8/.31 B118 26/1.02 15.7/.62 22/.86 20.1/.79 11.5/.45 18/.71
Z130 53/2.06 39.5/1.55 42.5/1.67 20/.79 21.5/.85 30./1.2 3.9/.15 5/.19 39/1.53 40/1.57 10/.39 B130 39/1.53 21.7/.85 35.5/1.40 31/1.22 18.5/.73 30/1.18
158
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
3-D Accessories
3-D Accessories
Photoelectric Sensors
M12 Stem (75mm usable length) XUZB, XUZM, XUZK, XUZX XUZ2001
3-D mounting base XUZ2001 XUZ2003
XUZ2001
XUZ2003
159
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
3-D Accessories
Dimensions
3-D Accessories, Dimensions
2.36
40 2.36
60
2.2
60
40.02
1.57
1.57
100
3.9
1.3
Photoelectric Sensors
2.8
33
73
M4 ∅0.21
0.18 5.5
0.17
4.5 ∅
4.5 ∅ 0.22
45 2.48
5.5
63
1.77
1.1
28
0.2
1.3
5
33
1.57
19.5
0.98 40
18.5 22.0
42 1.3
33
0.98
25
1.65
25
1.3
33
3.9
99
1.6
40
M5 M4 M3 M3
1.59
40.5
1.63
41.5
1.4
36
0.47
∅ 0.25 0.57 12
120
4.7
45
12.5
1.9
1.57
0.9 40
23
0.9
23
160
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUML, XUM Classic and XUL Sensing Patterns
ing Patterns
XUML
Thru-beam Retroreflective Proximity Diffuse
cm cm 1
6 6 cm
2 2
6 mm
T 2 2 1
4 R
4
Photoelectric Sensors
8 m 2 4 m 0.1 0.2 0.4 m
-2 0.2
-2
-4 -4 -2
-6 Su 8m -6 (1) Su 2m -1
Su 0.4 m
(2) Su 4m
10 x 10 cm target
(1) Polarized (2) Infra-red (std.) 1 white 90%
XUZC50 reflector 2 grey 18%
XUM Classic
Thru-beam system Reflex system Diffuse system (example 0.7 m)
cm cm
6 6 cm
4 4 2
Dia. 6 mm 1
E 2 R m 2 m m
7 0.2 2 3 0.2 0.4 0.7
-2 -2 Su 2 m (polarized) -1 target
-4 -4 -2 20 x 20 cm
Su 7m 6'
-6 -6 white 90%
23' Su 3 m (infrared) Su 0.7 m grey 18%
9' 2.29'
XUL
Thru-beam system Polarized reflex system Diffuse system Diffuse system with
background suppression
cm cm
mm mm
10 10
10 10 8 8
6 6
5 Dia.16 mm 5 4 4
m 2 2 m
161
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUJL, XUJ and XUE Sensing Patterns
XUJL, XUJ and XUE Sensing Patterns
XUJL
Thru-beam system Retroreflective system Polarized retroreflective system
cm
10 cm cm
6 6
6
20 mm 4 4
2 2 2
0 0 0
Photoelectric Sensors
20 m -2 10 m -2 8 m
-2
-6 -6 -6
-4 -4
-10 Su 15 m Su 8m Su ≤ 6 m
XUJ
Thru-beam system Retroreflective system Diffuse system (side approach recommended)
XUE
Thru-beam system Retroreflective system Diffuse system (side approach recommended)
4
D (cm)
8
10 20 30 40 50 60 70 80 90 100
4
8
cm
162
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUFN and XUFS Sensing Patterns
XUFN and XUFS Sensing Patterns
Thru-beam system
20 mm
mm mm mm mm mm
mm
Su ≤ 30 mm
Photoelectric Sensors
Su
20
(1)
120 10
10
120
20 200
mm
120 mm 100
100 mm
120 mm
4 2 - -
Su ≤ 200 mm
15
dia. of 2 4
60 beam
60 cm 100
50
Su
Su
6 3 -3 -6
Su
dia. of
beam
cm cm cm
cm
4 2 -2 -4 4 2 -2 -4
4 2 -2 -4
dia. of dia. of 6 3 -3 -6
dia. of beam beam dia. of
beam
beam
mm mm mm
35 mm
35 mm
mm mm
Su
200 300
Su
Su ≤ 300 mm
25
Su ≤ 200 mm
100 25
100 mm
cm
cm 100 150
4 2 -2 -4
50
dia. of 4 2 -2 -4
beam dia. of
Su
beam
cm cm
cm 6 3 -3 -6 8 4 -4 -8
4 2 -2 -4 dia. of dia. of
dia. of beam beam
beam
Brackets: XUFZ03, Z04 or Z05 Brackets: XUFZ03, Z04 or Z05 Brackets: XUFZ13, Z14 or Z15 Brackets: XUFZ13, Z14 or Z15
Cable: XUFZ910 or Z920 Cable: XUFZ911 or Z921 Cable: XUFZ910 or Z920 Cable: XUFZ911 or Z921
mm mm
mm mm
Su
Su
dia. 5 mm dia. 5 mm
Su
Su
cm 6 -6 cm 6 -6
cm 2 -2 cm 4 -4
dia. of dia. of
dia. of dia. of beam beam
beam beam
163
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN, XUFS, and XUE Sensing Patterns
XUFN, XUFS, and XUE Sensing Patterns
mm
Su ≤ 15 mm
Su ≤ 12 mm
Su ≤ 20 mm
Su ≤ 4 mm
Photoelectric Sensors
1
mm mm mm mm
50
1 1 2 1
40
15 20
Su ≤ 50 mm
10 10 2
30 10
20 mm 4 2 -2 -4 mm 4 2 -2 -4 mm 4 2 -2 -4 mm 4 2 -2 -4
mm 6 4 2 -2 -4 -6
dia. of
beam
XUFS0520
mm
70
50
Su ≤ 70 mm
cm
2 1 -1 -2
dia. of
beam
164
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUML and XUM Dimensions
XUML and XUM Dimensions
XUML Classic
Cable version
4.5
(3) 15
7.5 4
Photoelectric Sensors
3.5
18
25.5
34
41
3.2
17.5
8.3 (1) Oblo ng hole 3 x 4 mm
5
(2) LEDs
(1) (3) Oblo ng hole 8.2 x 3.2 mm
4 mm dia. 5 (4) Sensitivity potentiometer
Connector version
XUZA46 bracket
27 12 (3) 12 (2)
5.5
3.5
(1)
4
25.5
25.5
34
37
(1)
17.5
5
XUM Classic
Sensitivity Sensitivity
adjustment adjustment .39
.86
.94 22 10
LED 24
1.26
32
.31
1.45
8
37
1.00
25.5
Dia. 4.5
2 elongated
Dia. 4.5 Dual Dimensions inches
holes dia. 3 x 4 mm
165
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUL, XUJL and XUJ Dimensions
XUL, XUJL and XUJ Dimensions
XUL
.27
7
AC XUG A 14.5
.43
11
Photoelectric Sensors
10¡ 10¡
2.75
dia.
70
1.18
3mm B
30
1.5
39
2.14
54.5
1.10
28
B
1.10*
3.15
80
28
6mm 6mm
dia. dia.
A 10¡
.17
4.5
.55
14
.39
10
.47
12
10¡ A : 1 elongated hole, dia. 4.1 x 10 mm
10¡ 1.59
B : 1 elongated hole, dia. 3.1 x 10 mm
1.18
.81 40.5
30
20.6 20.6 *Front mounting (3mm dia.
1.18 .81 screws and inserts supplied)
30
XUJLM
XUJLM• • • • XUJLM• • • • P9 Front face Mounting bracket
XUZA49
0.1 2.4 0.1 2.6 1.07
1.1
2.6 (7) 61 2.6 (7) 66 (4) (8) 27.2
28
(4) 0.4
(9)
97.50
10
0.51
3.84
6.5 24 14 12
2.46 (62.5)
1.0 1.0 1.0 1.0 T
0.4 0.4 1.0 1.0
10 10 25 25
25 25 25 25 (10)
(1)
2.5 (62.5)
30 (6)
0.63 0.63
3.3
85
1.2
16 16
30.5
1.2
(5) 0.5
0.47 0.55 (3) 0.25 0.47 0.55 (3) 0.5 0.5 12.8
12 (2) 14 3.3 6.25 12 (2) 14 2.2 12.7 2.17 12.8
83.6 57 55.2
Notes
(1) cable gland – P11 (0.5" NPT standard) (5) cable gland – P9 (bottom entry option) (9) 2 oblong holes 6.5 dia. x 16.5
(2) 2 oblong holes 6.5 dia. x 10 mm (6) front mounting (4 mm screws and nuts incl.) (10) 1 oblong hole 6.5 dia. x 30.5
(3) 1 oblong hole 6.5 dia. x 24 mm (7) on polarized models only
(4) 8 oblong holes 4.2 dia. x 10 mm (8) ON/OFF LED – yellow
XUJ
2.40 .10 2.60
1.35
1.07
.05
61 LED LED sensitivity and 2.6 LED LED 66 sensitivity and 27.2
time delay time delay
potentiometers polarized potentiometers
models
only
3.34
R
85
.51
13
.10
2.6 E
A
1.18*
1.18
1.18
98.85
3.89
30
30
30
1.20
30.5
2.46
62.5
.66
17
B B
17
C
10¡10¡ 10¡ 10¡ 10 10
.39 .78 .35 .39 .78 .35 1.28
10 20 9 10¡ 20 9 32.6
2.88 2.24
75.9 57
* Front mounting
A : 1/2 " NPT Note : Receiver (R) and Emitter (E) (∅ 4 screws and inserts supplied)
B : 1 elongated hole ∅ 4.2 x 14 are reversed on diffuse models
C : CM8 / PG9 cable gland with background suppression Dual Dimensions inches
mm
166
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
XUE and XUD Classic Dimensions
XUE and XUD Dimensions
XUE
XUE.300..., XUE.10031 XUE.080319 Mounting bracket Lens hood for XUE/XUR
2.79 .43 1.31 XUZD01/D02
71 11 35.5 13¡
(3)
2.52
64
Photoelectric Sensors
22.3
.87
1.69
2.32
100
3.9
43
59
T
1.97
50
102.5 dia.
4.74
LED 6
(2)
.15
2.79
15 15
7
71
10¡ 10¡
1.28
.78 .90
34
20 23
1.31
35.5
1.30
25.5
.94
(1) 33
XUD Classic
.19 2.00 Mounting Plate
5 51
.26
6.6
.28
7.3
1.10
R
28
.03
7.4
1.46
37.3
1.26
E dia. 4.5
32
13.3
14.2
.52
.55
1.18 .27 .19 .43
.55 2 x dia. 3.2 5 111.06
14.2 30 7 3.5x5.2 3.5x5.2
Omega rail 27
mounting
167
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUFN and XUFS Dimensions
XUFN and XUFS Dimensions
Thru-beam (pairs)
L = 59.0 Ø0.08
Photoelectric Sensors
1500 2.2
0.7
Ø0.08 18
2.2
.11
.11
.11
3
3
L = 19.7 Ø0.04
M 2.6 dia. 0.06 M 2.6 dia. 0.06 M 2.6 dia. 0.03 500 1
x 0.45
0.39
1.5 x 0.45 1.5 x 0.45 0.8
.59 .19 3.5
15 5 90
3.5
10
.47
12
90
.47
.47
12
12
M4 M3 M0.11x0.02
M4
x 0.7 x 0.5 3x0.5
x 0.7
.59
15
M3
M4 M4 x 0.5
x 0.7 x 0.7
Ø0.08 Ø0.08
1 x dia. 1 1 x dia. 1 1 x dia. 1 1 x dia. 1 1 x dia. 0.5 1 x dia. 0.5 2.2 2.2
16 x dia. 2 x dia.
0.265 0.265 XUFZ910 ZUFZ921
Proximity (bifurcated)
Note: Emitter cable for XUFN05323, M6
XUFN04351, and XUFN02323
dia. 0.04 is marked with a white trace. Dia
dia. 0.08 dia. 0.04 On the amplifiers the emitter
dia. 0.08
32.5
dia. 0.08 1 1
1.3
2.2 2.2 is at the bottom. 0.04 (1)
2.2 Ø0.5
.70 13
18
M6 M4
Ø1.2
.11 .47
x 0.75
.59
15
2.2 5
M6 M 2.6
.70
18
x 0.75 x 0.45
.59
15
.11
3
dia.
.47
15 .59 12
0.04 (1) M3
3
2.2 M 6 1.5
15
38.1
x 0.5
970
3.5
90
x 0.75
.59
15
M4
.59
dia.
.47
3 12
2.2 M 2.6
11
8
x 0.7 x 0.45
M4
.47
x 0.7
90 0.11 12
.59
15
15
Nuts M6 M4 M3
dia. 0.06
3.5 .13
90 3.5
3.5 0.2
Across flats 10 7 5
3.5
1.5
90 5
dia. 0.1 dia. 2.5 Note: Used only with XUD detectors
2.5
( to be used only with XUD detectors ) Ø0.08 Ø0.08
2.2 2.2
XUFN05321 XUFN15322 XUFN05323 XUFN01321 XUFN04331 XUDZ01 XUFN02323
XUFN05331 XUFN15332 XUFN01331
XUFS0520
168
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Dimensions of Accessories for XUF, XUA
Dimensions of Accessories for XUF, XUA
XUF
XUFZ210
M8x1 M4
Photoelectric Sensors
15 1000 20
XUFZ310
M10x1 M6
10
15 1000 20
0.10
2.75
0.10
2.75
0.22 (1) 0.10 0.22 0.10 0.22 0.10
5.5 2.75 5.5 2.75 5.5 (1) 2.75
ø0.2 (5)
ø0.18
4.5
0.37
0.37
0.37
ø0.14 ø0.14 ø0.14
9.5
0.6
0.6
9.5
9.5
15
15
0.11 (1)
3.5 3.5 3.5
0.23
3 0.4
0.6
0.23
0.23
15
6
6
10
0.3 0.47 0.3 0.47 0.3 0.47
7.5 12 7.5 12 7.5 12
0.10
2.75
0.22 0.10 0.22 0.10
0.10
2.75
ø0.11 (1) 0.22 0.10
2.8 5.5 2.75 5.5 2.75 5.5 2.75
ø0.2 (5)
0.6
15
9.5 0.6
9.5 0.6
15
15
(1)
ø0.14 ø0.14 ø0.14
0.37
0.37
0.37
0.25 (1)
9.5
6.5
0.23
0.23
0.36
6
6
6
9.2
0.3 0.47 0.3 0.47 0.3 0.47
7.5 12 7.5 12 7.5 12
XUA
1.06 .87
10 27 38.3
22 .260 dia. .63
6.6 16
.16
4
169
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
XUV Detectors Dimensions
XUV Detectors Dimensions
Thru-beam (pairs)
3
3.5
65.5
2.5
dia.
1.39
35.5
.21
5.5
.78
20
11
.78
.19
5
.21
5.5
20
1.77
45
3.0
.17
4.5
78
.13
.78
20
.86
22
3.5
.47
.11
.11
3
12 .17 .78
dia. 17 3
4.5 20 .43
2 holes dia. 4.6 11
2 holes Ø 3.4
.39
1.73
10
44 .94
.39
10
24
Reflex/Diffuse
XUVN0244 XUVN0245 XUVN05415 XUVN02428 XUVN01428
1.18
30 1.02
dia. 26
.78 2 holes Ø 2.4 .11
.78
.39
20
10
20 3
.19
18.5
.90
.72
23
5
.31
.78
.43
20
11
8
.78
20
.86
22
.23
6
dia. .66 .13 2 elongated
2 holes Ø 3.4
17 3.5 holes Ø 3.4 x 4.4
.65
16.5
.35
9
.35
1.41
9
36
Amplifiers
XUVF Examples of utilization and mounting positions of the XULZ41 mounting bracket
3.60
91.5 45
.59
15
2.69 1.77
68.5 45
1.43
36.5
3.09
78.5
2.50
63.5
XUVH/J
1.26
32
.78
20
.39 1.18
.55
10 30
2.36 Dual Dimensions inches
14.2 mm
60
170
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Substitution Guide
Substitution Guide
Old Design New Design Old Design New Design Old Design New Design
Design 18 XU1P18PP340WL5 XUB1APAWL5 + XUZC50 XU2P18PP340W XUB2APBWL2R + XUB2AKSWL2T
Photoelectric Sensors
XU1N18NP340 XUB1BNANL2 + XUZC50 XU2B18PP340D XUB0APSNM12 + XUB0AKSNM12T XU5B18PP340 XUB0APSNL2
XU1N18NP340 XUB1BNBNL2 + XUZC50 XU2M18NP340 XUB0BNSNL2 + XUB0BKSNL2T XU5B18PP340D XUB0APSNM12
XU1N18NP340D XUB1BNANM12 + XUZC50 XU2M18NP340D XUB0BNSNM12 + XUB0BKSNM12T XU5B18PP340L5 XUB0APSNL5
XU1N18NP340D XUB1BNBNM12 + XUZC50 XU2M18NP340WD XUB0BNSWM12 + XUB0BKSWM12T XU5M18NP340 XUB0BNSNL2
XU1N18NP340L5 XUB1BNANL5 + XUZC50 XU2M18PP340 XUB0BPSNL2 + XUB0BKSNL2T XU5M18NP340D XUB0BNSNM12
XU1N18NP340L5 XUB1BNBNL5 + XUZC50 XU2M18PP340D XUB0BPSNM12 + XUB0BKSNM12T XU5M18NP340L5 XUB0BNSNL5
XU1N18NP340T10 XUB1BNANL2T10 + XUZC50 XU2M18PP340L10 XUB0BPSNL10 + XUB0BKSNL10T XU5M18NP340W XUB0BNSWL2
XU1N18NP340T10 XUB1BNBNL2T10 + XUZC50 XU2M18PP340L5 XUB0BPSNL5 + XUB0BKSNL5T XU5M18NP340WL5 XUB0BNSWL5
XU1N18NP340W XUB1BNAWL2 + XUZC50 XU2M18PP340W XUB0BPSWL2 + XUB0BKSWL2T XU5M18PP340 XUB0BPSNL2
XU1N18NP340W XUB1BNBWL2 + XUZC50 XU2M18PP340WD XUB0BPSWM12 + XUB0BKSWM12T XU5M18PP340D XUB0BPSNM12
XU1N18NP340WD XUB1BNAWM12 + XUZC50 XU2M18PP340WL5 XUB0BNSWL5 + XUB0BKSWL5T XU5M18PP340L5 XUB0BPSNL5
XU1N18NP340WD XUB1BNBWM12 + XUZC50 XU2N18NP340 XUB2BNANL2R + XUB2BKSNL2T XU5M18PP340W XUB0BPSWL2
XU1N18PP340 XUB1BPANL2 + XUZC50 XU2N18NP340 XUB2BNBNL2R + XUB2BKSNL2T XU5M18PP340WD XUB0BPSWM12
XU1N18PP340 XUB1BPBNL2 + XUZC50 XU2N18NP340D XUB2BNANM12R + XUB2BKSNM12T XU5M18PP340WL5 XUB0BPSWL5
XU1N18PP340D XUB1BPANM12 + XUZC50 XU2N18NP340D XUB2BNBNM12R + XUB2BKSNM12T XU5N18NP340 XUB4BNANL2
XU1N18PP340D XUB1BPBNM12 + XUZC50 XU2N18NP340WD XUB2BNAWM12R + XUB2BKAWM12T XU5N18NP340 XUB4BNBNL2
XU1N18PP340L5 XUB1BPANL5 + XUZC50 XU2N18NP340WD XUB2BNBWM12R + XUB2BKAWM12T XU5N18NP340D XUB4BNANM12
XU1N18PP340L5 XUB1BPBNL5 + XUZC50 XU2N18PP340 XUB2BPANL2R + XUB2BKSNL2T XU5N18NP340D XUB4BNBNM12
XU1N18PP340T10 XUB1BPANL2T10 + XUZC50 XU2N18PP340 XUB2BPBNL2R + XUB2BKSNL2T XU5N18NP340L5 XUB4BNANL5
XU1N18PP340T10 XUB1BPBNL2T10 + XUZC50 XU2N18PP340D XUB2BPANM12R + XUB2BKSNM12T XU5N18NP340L5 XUB4BNBNL5
XU1N18PP340W XUB1BPAWL2 + XUZC50 XU2N18PP340D XUB2BPBNM12R + XUB2BKSNM12T XU5N18NP340T10 XUB4BNANL2T10
XU1N18PP340W XUB1BPBWL2 + XUZC50 XU2N18PP340L5 XUB2BPANL5R + XUB2BKSNL5T XU5N18NP340T10 XUB4BNBNL2T10
XU1N18PP340WD XUB1BPAWM12 + XUZC50 XU2N18PP340L5 XUB2BPBNL5R + XUB2BKSNL5T XU5N18NP340W XUB4BNAWL2
XU1N18PP340WD XUB1BPBWM12 + XUZC50 XU2N18PP340W XUB2BPAWL2R + XUB2BKSWL2T XU5N18NP340W XUB4BNBWL2
XU1N18PP340WL5 XUB1BPAWL5 + XUZC50 XU2N18PP340W XUB2BPBWL2R + XUB2BKSWL2T XU5N18NP340WD XUB4BNAWM12
XU1N18PP340WL5 XUB1BPBWL5 + XUZC50 XU2N18PP340WD XUB2BPAWM12R + XUB2BKAWM12T XU5N18NP340WD XUB4BNBWM12
XU1P18NP340 XUB1ANANL2 + XUZC50 XU2N18PP340WD XUB2BPBWM12R + XUB2BKAWM12T XU5N18NP340WL5 XUB4BNAWL5
XU1P18NP340 XUB1ANBNL2 + XUZC50 XU2N18PP340WL5 XUB2BPAWL5R + XUB2BKSWL5T XU5N18NP340WL5 XUB4BNBWL5
XU1P18NP340D XUB1ANANM12 + XUZC50 XU2N18PP340WL5 XUB2BPBWL5R + XUB2BKSWL5T XU5N18PP340 XUB4BPANL2
XU1P18NP340D XUB1ANBNM12 + XUZC50 XU2P18NP340 XUB2ANANL2R + XUB2AKSNL2T XU5N18PP340 XUB4BPBNL2
XU1P18NP340L5 XUB1ANANL5 + XUZC50 XU2P18NP340 XUB2ANBNL2R + XUB2AKSNL2T XU5N18PP340D XUB4BPANM12
XU1P18NP340L5 XUB1ANBNL5 + XUZC50 XU2P18NP340D XUB2ANANM12R + XUB2AKSNM12T XU5N18PP340D XUB4BPBNM12
XU1P18NP340W XUB1ANAWL2 + XUZC50 XU2P18NP340D XUB2ANBNM12R + XUB2AKSNM12T XU5N18PP340L5 XUB4BPANL5
XU1P18NP340W XUB 1ANBWL2 + XUZ C50 XU2P18NP340W XUB2ANAWL2R + XUB2AKSWL2T XU5N18PP340L5 XUB4BPBNL5
XU1P18NP340WD XUB1ANAWM12 + XUZC50 XU2P18NP340W XUB2ANBWL2R + XUB2AKSWL2T XU5N18PP340T10 XUB4BPANL2T10
XU1P18NP340WD XUB1ANBWM12 + XUZC50 XU2P18NP340WD XUB2ANAWM12R + XUB2AKAWM12T XU5N18PP340T10 XUB4BPBNL2T10
XU1P18PP340 XUB1APANL2 + XUZC50 XU2P18NP340WD XUB2ANBWM12R + XUB2AKAWM12T XU5N18PP340W XUB4BPAWL2
XU1P18PP340 XUB1APBNL2 + XUZC50 XU2P18PP340 XUB2APANL2R + XUB2AKSNL2T XU5N18PP340W XUB4BPBWL2
XU1P18PP340D XUB1APANM12 + XUZC50 XU2P18PP340 XUB2APBNL2R + XUB2AKSNL2T XU5N18PP340WD XUB4BPAWM12
XU1P18PP340D XUB1APBNM12 + XUZC50 XU2P18PP340D XUB2APANM12R + XUB2AKSNM12T XU5N18PP340WD XUB4BPBWM12
XU1P18PP340L5 XUB1APANL5 + XUZC50 XU2P18PP340D XUB2APBNM12R + XUB2AKSNM12T XU5N18PP340WL5 XUB4BPAWL5
XU1P18PP340L5 XUB1APBNL5 + XUZC50 XU2P18PP340L10 XUB2APANL10R + XUB2AKSNL10T XU5N18PP340WL5 XUB4BPBWL5
XU1P18PP340W XUB1APAWL2 + XUZC50 XU2P18PP340L10 XUB2APBNL10R + XUB2AKSNL10T XU5P18NP340 XUB4ANANL2
XU1P18PP340W XUB1APBWL2 + XUZC50 XU2P18PP340L5 XUB2APANL5R + XUB2AKSNL5T XU5P18NP340 XUB4ANBNL2
XU1P18PP340WD XUB1APAWM12 + XUZC50 XU2P18PP340L5 XUB2APBNL5R + XUB2AKSNL5T XU5P18NP340D XUB4ANANM12
XU1P18PP340WD XUB1APBWM12 + XUZC50 XU2P18PP340W XUB2APAWL2R + XUB2AKSWL2T XU5P18NP340D XUB4ANBNM12
171
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Substitution Guide
Substitution Guide
Old Design New Design Old Design New Design Old Design New Design
Design 18 XU9N18NP340 XUB9BNANL2 + XUZC50 XUDJ003937S XUDA2NSMM8
172
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Substitution Guide
Substitution Guide
Old Design New Design Old Design New Design Old Design New Design
Design Compact XUJT060319P9 XUX0ARCTT16 + XUZX2000 XULH043539DH7 XUK9APANM12 + XUZK2003
XUJLM0811 XUX1ARCNT16 + XUZX2000 XUJT06031D1 XUX0ARCTT16 + XUZX2000 XULH043539DH7 XUK9APBNM12 + XUZK2003
XUJLM0811H7 XUX1ARCNT16 + XUZX2000 + XUZX2001 XUJT06031D2 XUX0ARCTT16 + XUZX2000 XULH043539H7 XUK9APANL2 + XUZK2003
XUJLM0811P9 XUX1ARCNT16 + XUZX2000 XUJT06031P9 XUX0ARCTT16 + XUZX2000 XULH043539H7 XUK9APBNL2 + XUZK2003
XUJLM0811T10 XUX1ARCNT16T10 + XUZX2000 XUJT100314 XUX0ARCTT16 + XUZX2000 XULH043539L05 XUK9APANL5 + XUZK2003
Photoelectric Sensors
XUJLM1503 XUX0ARCTT16T + XUZX2000 XUJT100314D1 XUX0ARCTT16 + XUZX2000 XULH043539L05 XUK9APBNL5 + XUZK2003
XUJLM1503H7 XUX0ARCTT16T + XUZX2000 + XUZX2001 XUJT100314D2 XUX0ARCTT16 + XUZX2000 XULH043539L10 XUK9APANL10 + XUZK2003
XUJLM1503P9 XUX0ARCTT16T + XUZX2000 XUJT100314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH043539L10 XUK9APBNL10 + XUZK2003
XUJLM1514 XUX2ARCNT16R + XUZX2000 XUJT100314P9 XUX0ARCTT16 + XUZX2000 XUJLM0619 XUK9ARCNL2 + XUZX2000
XUJLM1514H7 XUX2ARCNT16R + XUZX2000 + XUZ X2001 XUJT120318 XUX0ARCTT16 + XUZX2000 XUJLM0619H7 XUK9ARCNL2 + XUZX2000
XUJLM1514P9 XUX2ARCNT16R + XUZ X2000 XUJT120318D1 XUX0ARCTT16 + XUZX2000 XUJLM0619P9 XUK9ARCNL2 + XUZX2000
XUJM06031 XUX0ARCTT16 + XUZX2000 XUJT120318D2 XUX0ARCTT16 + XUZX2000 XULH06353 XUK1APANL2 + XUZK2003
XUJM060319 XUX0ARCTT16 + XUZX2000 XUJT120318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH06353 XUK1APBNL2 + XUZK2003
XUJM060319D1 XUX0ARCTT16 + XUZX2000 XUJT120318P9 XUX0ARCTT16 + XUZX2000 XULH06353D XUK1APANM12 + XUZK2003
XUJM060319D2 XUX0ARCTT16 + XUZX2000 XUJT700318 XUX0ARCTT16 + XUZX2000 XULH06353D XUK1APBNM12 + XUZK2003
XUJM060319H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUJT700318D1 XUX0ARCTT16 + XUZX2000 XULH06353H7 XUK1APANL2 + XUZK2003
XUJM060319P9 XUX0ARCTT16 + XUZX2000 XUJT700318D2 XUX0ARCTT16 + XUZX2000 XULH06353H7 XUK1APBNL2 + XUZK2003
XUJM06031D1 XUX0ARCTT16 + XUZX2000 XUJT700318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH06353L05 XUK1APANL5 + XUZK2003
XUJM06031D2 XUX0ARCTT16 + XUZX2000 XUJT700318P9 XUX0ARCTT16 + XUZX2000 XULH06353L05 XUK1APBNL5 + XUZK2003
XUJM06031P9 XUX0ARCTT16 + XUZX2000 XUK1ARCTL10 XUK0ARCTL10 + XUZK2003 + XUZA50 XULH06353L10 XUK1APBNL10 + XUZK2003
XUJM1000 XUX0AKSAT16T + XUZX2000 XUK1ARCTL2 XUK0ARCTL2 + XUZK2003 + XUZA50 XULH083534 XUK2APANL2R + XUZK2003
XUJM1000 XUX0ARCTT16T + XUZX2000 XUK2AKSAL10 XUK0AKSAL10 + XUZK2003 + XUK0AKSAL10T + XUZK2003 XULH083534 XUK2APBNL2R + XUZK2003
XUJM1000D1 XUX0AKSAM12T + XUZX2000 XUK2AKSAL10R XUK0AKSAL10 + XUZK2003 XULH083534D XUK2APANM12R + XUZK2003
XUJM1000D1 XUX0ARCTT16T + XUZX2000 XUK2AKSAL10T XUK0AKSAL10T + XUZK2003 XULH083534D XUK2APBNM12R + XUZK2003
XUJM1000D2 XUX0AKSAM12T + XUZX2000 XUK2AKSAL2 XUK0AKSAL2 + XUZK2003 + XUK0AKSAL2T + XUZK2003 XULH083534DH7 XUK2APANM12R + XUZK2003
XUJM1000D2 XUX0ARCTT16T + XUZX2000 XUK2AKSAL2R XUK0AKSAL2 + XUZK2003 XULH083534DH7 XUK 2APBNM12R + XUZK2003
XUJM1000H7 XUX0AKSAT16T + XUZX2000 + XUZX2001 XUK2AKSAL2T XUK0AKSAL2T + XUZK2003 XULH083534L05 XUK2APANL5R + XUZK2003
XUJM1000H7 XUX0ARCTT16T + XUZX2000 + XUZX2001 XUK2AKSAM12 XUK0AKSAM12 + XUZK2003 + XUK0AKSAM12T + XUZK2003 XULH083534L05 XUK2APBNL5R + XUZK2003
XUJM1000P9 XUX0AKSAT16T + XUZX2000 XUK2AKSAM12R XUK0AKSAM12 + XUZK2003 XULH083534L10 XUK2APANL10R + XUZK2003
XUJM1000P9 XUX0ARCTT16T + XUZX2000 XUK2AKSAM12T XUK0AKSAM12T + XUZK2003 XULH083534L10 XUK2APBNL10R + XUZK2003
XUJM100314 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10 XUK0ARCTL10 + XUZK2003 + XUK2ARCTL10T + XUZK2003 XULH153538 XUK0AKSAL2 + XUZK2003
XUJM100314D1 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10R XUK0ARCTL10 + XUZK2003 XULH153538D XUK0AKSAM12 + XUZK2003
XUJM100314D2 XUX0ARCTT16 + XUZX2000 XUK2ARCTL10T XUK2ARCTL10T + XUZK2003 XULH153538H7 XUK0AKSAL2 + XUZK2003
XUJM100314H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK2ARCTL2 XUK0ARCTL2 + XUZK2003 + XUK2ARCTL2T + XUZK2003 XULH153538L05 XUK0AKSAL5 + XUZK2003
XUJM100314P9 XUX0ARCTT16 + XUZX2000 XUK2ARCTL2R XUK0ARCTL2 + XUZK2003 XULH303538 XUK0AKSAL2 + XUZK2003
XUJM120318 XUX0ARCTT16 + XUZX2000 XUK2ARCTL2T XUK2ARCTL2T + XUZK2003 XULH303538D XUK0AKSAM12 + XUZK2003
XUJM120318D1 XUX0ARCTT16 + XUZX2000 XUK5AKSAL10 XUK0AKSAL10 + XUZK2003 XULH303538DH7 XUK0AKSAM12 + XUZK2003
XUJM120318D2 XUX0ARCTT16 + XUZX2000 XUK5AKSAL2 XUK0AKSAL2 + XUZK2003 XULH303538L05 XUK0AKSAL5 + XUZK2003
XUJM120318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK5AKSAM12 XUK0AKSAM12 + XUZK2003 XULH303538L10 XUK0AKSAL10 + XUZK2003
XUJM120318P9 XUX0ARCTT16 + XUZX2000 XUK5ARCTL10 XUK0ARCTL10 + XUZK2003 XULH703535 XUK5APANL2 + XUZK2003
XUJM700318 XUX0ARCTT16 + XUZX2000 XUK5ARCTL2 XUK0ARCTL2 + XUZK2003 XULH703535 XUK5APBNL2 + XUZK2003
XUJM700318D1 XUX0ARCTT16 + XUZX2000 XUK9AKSAL10 XUK0AKSAL10 + XUZK2003 + XUZA50 XULH703535D XUK5APANM12 + XUZK2003
XUJM700318D2 XUX0ARCTT16 + XUZX2000 XUK9AKSAL2 XUK0AKSAL2 + XUZK2003 + XUZA50 XULH703535D XUK5APBNM12 + XUZK2003
XUJM700318H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XUK9AKSAM12 XUK0AKSAM12 + XUZK2003 + XUZA50 XULH703535H7 XUK5APANL2 + XUZK2003
XUJM700318P9 XUX0ARCTT16 + XUZX2000 XUK9ARCTL10 XUK0ARCTL10 + XUZK2003 + XUZA50 XULH703535H7 XUK5APBNL2 + XUZK2003
XUJT06031 XUX0ARCTT16 + XUZX2000 XUK9ARCTL2 XUK0ARCTL2 + XUZK2003 + XUZA50 XULH703535L05 XUK5APANL5 + XUZK2003
XUJT060319 XUX0ARCTT16 + XUZX2000 XULH043539 XUK9APANL2 + XUZK2003 XULH703535L05 XUK5APBNL5 + XUZK2003
XUJT060319D1 XUX0ARCTT16 + XUZX2000 XULH043539 XUK9APBNL2 + XUZK2003 XULH703535L10 XUK5APANL10 + XUZK2003
XUJT060319D2 XUX0ARCTT16 + XUZX2000 XULH043539D XUK9APANM12 + XUZK2003 XULH703535L10 XUK5APBNL10 + XUZK2003
XUJT060319H7 XUX0ARCTT16 + XUZX2000 + XUZX2001 XULH043539D XUK9APBNM12 + XUZK2003 XULJ043539 XUK9ANANL2 + XUZK2003
173
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Substitution Guide
Old Design New Design Old Design New Design Old Design New Design
Design Compact 50 x 50 XUMH023539L10 XUM0APSAL10 + XUZM2003 XUMLJ0451S XUM1ANBM8 + XUZM2003
XULJ043539 XUK9ANBNL2 + XUZK2003 XUMH03353 XUM0APSAL2 + XUZM2003 XUMLJ0854 XUM2ANANL2R + XUZM2003
XULJ043539D XUK9ANANM12 + XUZK2003 XUMH03353L10 XUM0APSAL10 + XUZM2003 XUMLJ0854 XUM2ANBNL2R + XUZM2003
XULJ043539D XUK9ANBNM12 + XUZK2003 XUMH07301 XUM2AKSNL2T + XUZM2003 XUMLJ0854S XUM2ANANM8R + XUZM2003
XULJ06353 XUK1ANANL2 + XUZK2003 XUMH07301L10 XUM2AKSNL10T + XUZM2003 XUMLJ0854S XUM2ANBNM8R + XUZM2003
Photoelectric Sensors
174
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
General
General
Principles of A photo-electric sensor basically comprises a light beam emitter (light emitting
Composition of diode) and a light sensitive receiver (photo-transistor).
optical detection a photo-electric A light emitting diode is an electronic semi-conductor component which emits
sensor light when an electrical current flows through it. This light can be visible or
invisible, depending on the transmission wavelength.
Detection occurs when an object enters the transmitted light beam and, in so
doing, affects the intensity of the light at the receiver. As the light intensity at
Photoelectric Sensors
the receiver decreases, a point is reached whereby the output of the sensor
changes state.
1 3 4
Depending on the model, the transmission beam is either infra-red, visible red
Light spectrum or visible green.
Visible red light emitting diodes (LEDs) and photo-transistors are used for
plastic fiber optic and polarized retroreflective system sensors.
10
1 nm 400 nm 750 nm 3 µm
100 200 300 500 600 700 800 900 1000 1100
175
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Detection Systems
Detection Systems
176
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems
Thru-beam The thru-beam system requires precise alignment of the emitter and receiver.
Alignment of emitter
system and receiver
For long sensing distance thru-beam systems it is recommended that the
mechanical alignment tool be used.
Photoelectric Sensors
Retroreflective The reflector comprises a considerable number of corner cube cavities which
Function of ensure total reflection of all light rays back along the same path.
system the reflector Types of reflector:
- circular,
- rectangular,
- reflective tape.
The reflector orientation angle (α) must be between 10 and 20°
(see sensing distance correction coefficient below).
40
α 30
20
10
0
0 80 % 100 %
177
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems
Retroreflective The positioning of the reflector must be very precise, in order to reflect the
Positioning transmitted beam back to the receiver.
system (cont.) the reflector
Photoelectric Sensors
Incorrect orientation
Incorrect centering
Correct position
When using a reflector with small corner cubes (for example XUZC80) for short
Using reflectors for sensing distances (D < 10% Sn), almost all of the beam is reflected back to the
short sensing emitter and the sensor fails to
distances operate correctly. The use of a reflector with large corner cubes (for example
XUZC24 and XUZC50) ensures that the light beam will be
reflected back towards the receiver.
D D
D < 10% Sn
1
2
1
3
4
1Non polarized
2Vertically polarized
3Horizontally polarized
4The reflector depolarizes the light beam
178
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of the Various Detection Systems
Specific Aspects of the Various Detection Systems
Photoelectric Sensors
0,5 Sn
Object reflection
coefficient
0,1 Sn
10 % 50 % 100 % 140 %
White paper
Brown cardboard
Planed wood
Wooden pallets
Aluminum
Plastic bottles
Rubber
The curve above indicates the usable sensing distance (Sn) correction factor
related to the reflection coefficient of the object.
Note: If the application requires that different object materials be
detected at the same distance, the choice of sensor and adjustment of the
sensitivity is based on the object which has the lowest reflection coefficient.
ON ON
Object 1 Object 2
Transmitter
Background
Back- Non
ground
spot detection
Detection
threshold Object
spot 1
Detection
Object
spot 2
179
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Systems - General
Specific Systems - General
Fiber optics The fiber optic acts as a light conductor. Light rays entering the fiber at a certain
Principle angle are conveyed to the required place, with minimum loss.
1 2
Photoelectric Sensors
1 core 2 sheath
Plastic fibers The core of the fiber is flexible plastic (PMMA). There is
usually a single fiber, 0.25 to 1 mm,
depending on the model.
They are used with amplifiers transmitting red light.
Minimum bend radius:
-10 mm for fiber with 0.25 mm core,
-25 mm for fiber with 1 mm core.
Advantage: Fibers can be cut to the required length.
Separate amplifier.
XU 3537
Specific aspects
H00
D-
-Compact.
t
-Detection of very small
objects.
-Precise detection.
Proximity Detection of color index mark on contrasting plain color background. Principle
Detection of of operation based on the difference between the colors (contrast) of the
diffuse system contrasting colors background and index mark in green or red light. The stronger the contrast
for color mark between the colors, the higher the difference
between the received signal strengths and the more reliable the
reading detection.
180
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Outputs and Wiring
Outputs and Wiring
Photoelectric Sensors
3-wire BN + • Protected against overload and
3-wire DC PNP short-circuit.
BK
PNP or NPN type • 4 models:
BU – - PNP light switching,
- NPN light switching,
BN + - PNP dark switching,
NPN
BK
- NPN dark switching.
BU –
181
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Outputs and Connections
Outputs and Connections
Output
Light switching:
functions beam received
= output ON
Thru-beam and
retroreflective systems:
OFF
Photoelectric Sensors
ON
ON
Proximity diffuse system:
OFF
Dark switching:
beam not received
(broken)
= output ON Thru-beam and
ON
retroreflective systems:
OFF
ON
Connection Factory fitted molded cable, good protection against splashing liquids.
Pre-cabled
methods
182
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Complementary Functions
Complementary Functions
Output signal Some models of XUJ, XUE and XUV sensors incorporate an
Principle adjustable time delay.
time delay The following configurations are possible:
- light switching output, time delay on beam break,
- dark switching output, time delay on beam break,
- light switching output, time delay on beam make,
- dark switching output, time delay on beam make.
Photoelectric Sensors
Delay on beam make Delay on beam break
Object leaves detection zone: beam Object enters detection zone: beam
made broken
Object enters detection zone: beam Object leaves detection zone: beam
made broken
The time delay is triggered as the beam is made and the output will not change
Time delay on beam state until the preset time (T) has elapsed. If the beam is
make broken and re-made during this period, the timer resets to zero.
Receiver state
(beam made/
t
beam broken)
Time delay t
period T
1
Light switching
output t
0
Dark switching 1
output t
0
The time delay is triggered as the beam is broken and the output will not change
Time delay on beam state until the preset time (T) has elapsed. If the beam is made and re-broken
make during this period, the timer resets to zero.
Receiver state
(beam made/
t
beam broken)
Time delay t
period T T
Light switching 1
output t
0
Dark switching 1
output t
0
183
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Complementary Functions
Complementary Functions
One shot function The one shot function is an extension of the time delay function and can
Principle either be on beam make or on beam break.
As the beam is made or broken, the output of the sensor immediately
changes state and remains in this condition during the preset time T,
irrespective of further beam makes or breaks.
After the preset time T has elapsed the output returns to its initial state,
until the next beam make or beam break.
Photoelectric Sensors
Time delay and Sensor type Time delay Monostable Time delay
Sensors incorporating function function
one shot function feature
-
XUJT••••• Adjustable
0.25 to
and/or c
15 s
XUET••••• Adjustable
q 0.03 to 1 s
or a or a or 1 to 60 s
XUVH••••• 40 ms
XUVJ••••• fixed
XUVF••••• 40 ms
fixed
XUVT••••• Adjustable
q 0.03 to 3s or 1
or a or a to 60 s
Beam break test For verification of correct operation of the sensor. A test input enables the transmitted beam to be broken in order to verify
that the output of the sensor changes state. This function is incorporated in sensors type XUM and XUV.
BN + BN +
VI VI
BU – BU –
184
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Complementary Functions
Complementary Functions
Verification of Signal 1,2 A red LED illuminates when the intensity of the light beam
level 0,81 at the receiver is no longer strong enough to ensure correct
correct operation of the sensor. This being the possible result of
operation Red LED
dirty lenses, excessively polluted atmosphere, disturbance
of optical alignment, etc.
This function is incorporated in retroreflective and
LED off LED on thru-beam system sensors type XU•B18,
Photoelectric Sensors
XU•M18 (DC), XUM, XUJ, XUD and XUV.
Signal 1,2 In addition to the red LED indicting loss of received beam
level 1
0,8 strength, a warning output is available for
remote signalling. The output signal is delayed by 160 ms to
eliminate temporary conditions.
Red LED
This function is incorporated in retroreflective and
t t
thru-beam system sensors type XUM, XUJ and XUV.
Warning 1
output 0
Green LED
Optimum
alignment
185
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Complementary Functions
Complementary Functions
Synchronization The synchronization input is an additional wire which is used externally to either activate or deactivate the sensor. When the
sensor is deactivated (blocked) its output is OFF, irrespective of the presence or absence of an object. This synchronization
inputs input is incorporated in amplifiers for use with optical sensing heads (type XUV).
PNP
Sensor deactivated (blocked)
Output OFF
–
+
Synchronization input connected to “+”
PNP
Sensor activated
+
NPN type sensors Synchronization input connected to “–”
NPN
Sensor deactivated (blocked)
Output OFF
–
186
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Curves
Curves
Photoelectric Sensors
Acceptable detection
T = emitter
R R = receiver
d ≤ Sn
1 Effective beam
2 Mask
1 2
Acceptable detection
T = emitter
R = receiver
T/R
Sn
187
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Curves
Curves
Gain curves The operating distance (Sa) is the assured operating distance of the sensor,
Principle taking into account the environment (dust, etc.) and the
reflector used.
Sa < Sn (Sn = nominal sensing distance).
The gain curve indicates the acceptable safety margin for a thru-beam or
retroreflective system sensor before jeopardizing its correct operation.
The gain is defined by the following ratio:
Photoelectric Sensors
Gain 1 corresponds to the minimum signal received which will cause the sensor’s
output to change state.
100
Polluted environment
50
(necessary gain = 10)
Sa ≤ 3 m
Very polluted environment
10
(necessary gain = 50)
5
Sa ≤ 1 m
1
0,1 0,2 0,4 0,8 2 3 5 10 15 20
0,6 1 4 6 D (m)
1
0,2 0,6 1 2 4 6 8 10
0,1 0,4 0,8 3 5 9 D (m)
188
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Standards and Certifications - Parameters Related to the Environment
Standards and Certifications - Parameters Related to the Environment
Influence of climatic Standard photo-electric sensors are designed to have a high immunity to
Ambient light ambient light.
environment
Photoelectric Sensors
Note: Caution should be taken, however, in the event of pulsed lights (neon signs,
flashing beacons, flash lights, etc.).
3 Outdoor mounting
1 Protective cover
2 Sun shade
3Thermally insulated support
Resistance to Owing to the very wide range of chemicals encountered in modern industry, it is very difficult to give general
guidelines common to all sensors. To ensure lasting efficient operation, it is essential that the chemicals coming into
chemicals in the contact with the sensors will not affect their casings and, in doing so, prevent their reliable operation. Refer to
environment “Enclosure Materials” on the specification pages relating to the various sensor models.
Resistance to shock The sensors are tested in accordance with the standard IEC 60068-2-27.
Resistance to The sensors are tested in accordance with the standard IEC 60068-2-6.
vibration
Degrees of Please refer to the reference/characteristic pages for the various sensors.
protection IP67: Protection against the effects of immersion, tested in accordance with the standard IEC 60529. sensor
immersed for 30 minutes, in 1 m of water.
No deterioration in either operating or insulation characteristics is permitted.
189
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Specific Aspects of Electronic Detectors
Specific Aspects of Electronic Detectors
Terminology MA
Ir Leakage current (Ir)
The leakage current (Ir) corresponds to the current flowing through the sensor
when in the “open” state.
XU Characteristic of 2-wire type photo-electric sensors.
Supply voltage V on
First-up delay
Detector operational at state 1
The time (t) between the connection of the power supply to the
Detector at state 0 photo-electric sensor and its fully operational state.
t
Delays
• Response time (Ra):
Ra Rr The time delay between entry of an object into the operating zone of
the sensor, and the subsequent change of output state.
This parameter limits the speed and size of the object.
• Recovery time (Rr):
The time delay between an object leaving the operating zone,
in which it is being detected, and the subsequent change of
output state.
This parameter limits the interval between successive objects.
Supply Check that the voltage limits of the sensor are compatible with the rated voltage
Photo-electric of the AC supply used.
detectors for
AC circuits
(AC and AC/DC models)
DC source: Check that the voltage limits of the sensor and the
Photo-electric sensors acceptable level of ripple, are compatible with the supply used.
for DC circuits
190
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Specific Aspects of Electronic Detectors
Specific Aspects of Electronic Detectors
Types of output These sensors are wired in series with the load to be switched.
2-wire Because of this they are subject to:
- a leakage current (in the open state),
- a voltage drop (in the closed state).
AC/DC
For polarized (polarity conscious) DC sensors, the supply polarities must be
observed.
AC/DC For non polarized (not polarity conscious) AC sensors, the supply
Photoelectric Sensors
polarity load connections to + or – are immaterial.
Advantages:
- The sensors can be wired in the same way as mechanical limit switches.
- For AC and AC/DC models, they can be connected to either positive (PNP)
or negative (NPN) logic inputs. No risk of incorrect connections.
But:
Check the possible effects of residual current and voltage drop on the input
device being controlled (pick-up and drop-out thresholds).
These sensors comprise 2 wires for the DC supply and a third wire for
3-wire transmission of the output signal.
- PNP type: switching the positive side to the load,
+ - NPN type: switching the negative side to the load.
PNP
The programmable universal sensors provide a choice of function,
either: PNP/N.O., PNP/N.C., NPN/N.O., NPN/N.C.
–
+ Advantages:
- Programmable output signal, no residual current, low voltage drop.
NPN - N.O. + N.C. versions, for solid state input coincidence control
– (4-wire type: XUJ and XUE).
- Programmable models, reduced stock levels.
But:
Certain models must only be used with their designated PNP or NPN type of
logic input.
1,5 1,5
107 10
7
106 106
220 V
110 V
220 V
110 V
48 V
24 V
48 V
24 V
191
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors
U sensor =
n sensors
192
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors
Photoelectric Sensors
• When the contact closes, the
sensor will not operate until a cer-
tain time “T” has elapsed (corre-
sponding to the first-up delay).
AC AC AC
Scheme 1 Scheme 2 Scheme 3
No restrictions.
3-wire type The use of “flywheel” diodes is
recommended when an inductive load
(relay) is being switched.
No restrictions.
5-wire type For these sensors, the supply and
output circuits are electrically separate.
The sensor/relay contact galvanic
isolation is 1500 to 2500 V, depending
on the model.
The maximum voltage across each
contact is 250 Vac, depending on the
model.
193
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors
1 1
≥10
cm
2
2
1 Control cable
2 Power cable
The level of dust and damp protection depends on how carefully the screws,
Dust and damp seals, cable glands, blanking plugs, etc. have been tightened.
protection of cable To ensure efficient dust and damp protection, use the correct diameter cable for
glands the cable gland used.
Capacitive load At switch-on, it is necessary to limit (by resistor) the charging current of the
capacitive load C.
(greater than -R The voltage drop in the sensor can also be taken into account by
0.1 µF) subtracting it from the supply voltage for calculation of R.
-C V (supply)
R=
I max. (sensor)
Load + If the load comprises an incandescent lamp, the cold state resistance can be 10
times lower than the hot state resistance. This can cause very high current levels
comprising an a on switching.
incandescent –
Fit a pre-heat resistance in parallel with the photo-electric sensor.
lamp + V2
R= x 10
P
a V = supply voltage
P = lamp power
–
194
© 1997-2002 Schneider Electric All Rights Reserved 10/02
Photoelectric Sensors
Electrical Installation of Electronic Detectors
Electrical Installation of Electronic Detectors
The sensors output will not Output stage faulty or complete failure Check that the sensor is compatible with the supply being used.
change state when an object of the sensor (in either case, the Check the load current characteristics:
enters the operating zone sensor must be replaced), or the short- - if load current I ≥ maximum current, a relay should be interposed
circuit protection has tripped between the sensor and the load,
- if load current I ≤ maximum current, check for wiring faults (short-circuit).
Photoelectric Sensors
In any case, a “quick-blow” fuse should be placed in series with the sensor.
Wiring error Verify that the wiring conforms to the wiring shown on the sensor
label or instruction sheet.
Supply fault Check that the sensor is compatible with the supply (AC or DC).
Check that the supply voltage is within the voltage limits of the sensor.
Remember that with rectified, filtered supply: U peak = U nominal x √2.
With a retroreflective system: The retroreflective system must operate in conjunction with a reflector.
- incorrect use of reflector, Respect the operating distances. Clean the reflector.
- poor state of reflector Replace the reflector if it has been damaged.
False or erratic operation, with or Influence of reflective background or Refer to the instruction sheet supplied with the sensor. For adjustable sensors,
without the presence of an object surface of the object (stray reflections) reduce or increase the sensing distance.
in the operating zone
Influence of immediate environment Check the cleanliness of the lenses and reflector.
Fit a lens hood, where required.
Influence of transient interference on Ensure that any DC supplies, when derived from rectified AC, are correctly
the supply lines. smoothed (C > 400 µF).
Separate AC power cables and DC low level cables.
Where very long distances are involved, use suitable cable: screened and twisted
pairs of the correct cross-sectional area
Equipment liable to emit Position the sensors as far away as possible from any sources of interference.
electromagnetic interference
Response time of the sensor too slow Check the suitability of the sensor for the object to be detected.
for the particular object being detected If necessary, select a photo-electric sensor with a higher switching frequency.
Influence of high temperature Eliminate sources of radiated heat, or protect the sensor casing with a heat shield.
Realign, having adjusted the temperature around the fixing support.
Contact deterioration On an inductive load, use an RC suppressor connected in parallel with the load.
Example: LA4D•••
To eliminate contact contamination, the minimum current recommended is 15 mA.
The relay output models are not recommended for rapid counting of objects since
their service life is too short.
Use models with solid state output.
Dusty atmosphere Clean the lenses and reflectors with a soft cloth.
195
10/02 © 1997-2002 Schneider Electric All Rights Reserved
Photoelectric Sensors
Photoelectric Sensors
196
© 1997-2002 Schneider Electric All Rights Reserved 10/02