Beruflich Dokumente
Kultur Dokumente
0.05
Rf
La 230V Vf = 230 = (Rf+Lfp) if
Lf if(t) = 4(1-e-3.59t)A
Ea if(t) = 4A
(-)
3) I2 + Rf = 42 x 57.5 = 0.92 KW
438.82 x 0.05 = 9.63 KW
Rtot = 1.8 + 0.92 + 9.63 = 12.35
EF = Putil / Ping
Ping = Putil + Pperd = 100 + 12.35 = 112.35 KW
EF = 100 / 112.35 = 89%
4) Ping = Ea x Ia
Ping = 251.94 x 438.8 = 110.55 KW
Pm primo = Ping / 0.96
Pmp = 115.2 kw = 154.4 HP
Wm = 157.5 x 30/ = 1504 RPM
If = 258/125 = 2.06A
Ia = 200 +2.06 = 202.06 A
Ea = Va + Ra Ia = 258 + 0.06 x 202.06
2) Ea = 262.12 volt
3) Ping = 50,000 + Ra ia2 + R + if2 +1000
= 50,000 + 0.06 x 202.062 + 125 x 2.062 + 1
= 50,000 + 2449.6 + 530.5 + 1000
= 53980.1 VAT
EF = 50/53980.1 = 92.63%
Ping = Ea x ia = 262.12 x 202.06 + 1000 = 53,964 VAT
HP = 72.34 =
IL = 200A
If = 250/125 = 2A
ia = 202 A
MAQUINAS DE CORRIENTE CONTINUA HUBER MURILLO M Page 3
SOLUCION DE PROBLEMAS DE MAQUINAS DE CORRIENTE CONTINUA
Solución:
A) Radj = 0
Ifmax = 120/24 = 5A
Radj = 30
Ifmin = 120 / 24+30 = 2.22A
5A 128 volt
2.22 A 87 volt
B) EA=
RPM = 1800
Radj = 0 Ifmax = 5A 1800 RPM + 128 V
24 + 6
D) Ia = 50A a 1700 RPM Ea = 106 volt
If = ?
La tension Ea = Gaf x if x Wm
volt
Rf + Radj =
Va = Ea – Ra ia = GafifWm – 0 (ia=0)
Va = 2 x 1 x 30 = 188.5 voltios
Ea = 188.5 voltios
Pérdidas = 540 = ia2 x Ra = ia2 x 0.6
ia = 30 amp
Va = 188.5 – 30 x 0.6 = 170.5 volt.
Putil = Va x ia = 170.5 x 30 = 5,115 VAT
Reg(%) =
EF(%) =
FP = 1
0.20= Va=157.1 volt
Va = Ea – Ra ia
0 = 188.5 – 0.6 x iacc
iacc =
Está acoplado a una carga de 0.1 Kg - m2 de inercia, cuyo torque esta definido
como 0.10Wm para limitar la corriente de arranque el motor es arrancando con
una resistencia de 3.4Ω está en serie con la armadura y aplicándosele 240 volt.
La corriente de campo es If=1 amp
Calcular:
3.4Ω
If
240 voltios + Vf -
a)
…(1)
…(2)
…(3)
MAQUINAS DE CORRIENTE CONTINUA HUBER MURILLO M Page 8
SOLUCION DE PROBLEMAS DE MAQUINAS DE CORRIENTE CONTINUA
…(4)
b)
c)
d)
e)
f)
g)
h)
i)
240 voltios
Ea
3.4
0.6
240 voltios
0.012
wm
+ ia
Ra
Rf Lf
La
230v
115v
Ea
_ F1
Vf
F2
Trabajando en vacio :
Gaf = 0.6017 Hy
Te – Tl = Jt x P x Wm + Dt x Wm ........ (3)
Te = D x Wm
Gaf x If x Ia = Dt x Wm
0.6017 x 2.875 x 5.2 = Dt x 1265 x
30
Dt = 0.0679 N - m – seg.
Tl = 143.6 N – m.
Valor estacionario
Ifo
If(t)
If = Ifo + If(t)
V + V Ia = Iao + Ia(t)
Reemplazando ( ) en ( 1 ) :
Vf + Vf = Rf ( Ifo + If ) + Lf p( Ifo + If )
Luego :
Vf = R + If + Lf P If .................. (3)
Reemplazando en 2 :
( Wmo + Wm ).
Luego :
Vf = -11.5 Volt.
-11.5 = Rf If + L + P If
-11.5 = ( 40 + 20P ) If
11.5
If(t) = - (1- e-2t) Amp.
40
+ 0.6017 x 1192 x x (-0.2875)
30
Ecuación mecanica
-Tl + Gaf Ifo Iao + Gaf If Iao + Gaf Ifo Ia + Gaf If Ia = Jp Wmo + Jp Wm + D
Wmo + D Wm
Wm
116.85
t(seg.)
t=0.1346
Wmo - Wm = rad/seg.
Wm│tmax= 0
t
-24.275e-2tmax
0 = 490.74 e – 24.492e-2tmax
Ln ( 490.74/24.492 = e(24.275-2)tmax)
3 = 22.275 tmax
Ia
Ra
Rf Lf Lf CARGA EN CORTO
CORCUITO
If
Ea
+ Vf _
Solucion:
= Putil/ Pentrada
Vf= Rf x if
200 = Rf x 1 A
1.1765 Vpc = Vv
1.1765 ( 212.5) = Vv = Ea
Ea = Ra x ia ( 80%) + Vc
VL = 220 V
Gaf= 1.999Hy
Te = Gaf x if x ia
Te = 1.999x(1) x 15.5
Te = 30.98 N-m
V= Ea- Raia
= 88%
PROBLEMA N° 9.- Una MCC tipo shunt de 5HP, 120 voltios, 41 amperios, 1800 RPM;
trabaja a plena carga y utiliza escobillas electrografíticas para conectar el circuito de
armadura y el tablero de bornes de la máquina. Los parámetro del MCC son los
siguientes:
IL Ia
+
If Ra
Lf
Rf Lf
Ea
_
Rf75o = 0.6558 Ω.
Rft75o = 145.8 Ω.
120 = Rf X If ………(1)
If = 0.8234 A.
Y tambien:
Gaf = 0.5870 Hy
IL = 41 + 0.8234
IL = 41.8234 A.
V = Raia + Ea + 2 V
118= 26.896+ Ea
Ea=91.1 volt
Ping= V x IL
Rs = 0.3 Ω