5 Port Solenoid Valve


t ion :
su m p
r co n
po w e
d u ce d rcuit]
R e aving ci
ower s
5 w ith p

0.5 w
[W
Series VF3000

rd]

1. 5 5 vent
iona
l: 2 .0 W
[Standa
) ∗ Wit
h DC
light

 Built-in full-wave rectifier (AC)


 Noise reduction
(Con Noise is considerably reduced by changing it to DC mode with
a full-wave rectifier.
Power consumption is reduced  Reduced apparent power
by power saving circuit. Conventional: 5.6 VA → 1.55 VA
Power consumption is decreased by approx. 1/3 by reducing
the wattage required to hold the valve in an energized state.
(Effective energizing time is over 40 ms at 24 VDC.) Refer to
 Built-in strainer in the pilot valve
Unexpected troubles due to foreign matter can be prevented.
electrical power waveform as shown below.
Note) Be sure to mount an air filter on the inlet side.

Electrical power waveform with power saving circuit


Applied voltage
24 V
Rubber material: HNBR
Ozone-resistant specification
0V ∗ The pilot valve poppet is made of FKM.

Standard
1.55 W

Energy saving
0.55 W
With power saving circuit
0W
40 ms

Strainer

RoHS compliant

Series VF1000/3000/5000
CAT.ES11-99B
VF-B.qxd 10.12.1 9:37 AM Page 2

Series VF1000/3000/5000

Model Selection by Operating Conditions q


Single Unit

Sonic conductance Port Electrical Light/surge Manual


Series Type of actuation Voltage
C [dm3/(s·bar)] size entry voltage suppressor override

VF1000 2-position single


VF1000
Grommet

VF3000
M5 x 0.8
0.76
VF5000 1/8

L-type plug
2-position double connector
VF1000
VF3000

Non-locking
Body ported

push type
VF3000
VF5000 1/8
4.0 P. 1
1/4 M-type plug
connector

3-position closed center


DC
VF5000  With surge voltage
suppressor Push-turn
12 VDC  With light/surge locking
3-position exhaust center 24 VDC DIN slotted type
voltage suppressor
terminal  With surge voltage
24 VAC
1/4 suppressor (Non-
8.8 100 VAC
3/8 polar)
200 VAC  With light/surge
3-position pressure center 110 VAC voltage suppressor
220 VAC (Non-polar)
240 VAC AC
 With light/surge
voltage suppressor
VF3000 2-position single DIN (EN1753 Push-turn
01-803) locking
terminal lever type

2-position double 1/4


3.1
3/8
Base mounted

3-position closed center

P. 15
VF5000 Conduit
terminal
3-position exhaust center

1/4
9.4 3/8
1/2
3-position pressure center

Features 1
VF-B.qxd 10.12.1 9:37 AM Page 3

Series VF1000/3000/5000

Model Selection by Operating Conditions w


Manifold

EXH port Manifold Applicable Applicable


Series
type base model valve stations

VF1000 VV5F1-30
4(A), 2(B) port
M5, 1/8
Common EXH

5/3(R) port
1(P) port 1/8
1/8 VF130 2 to 20
VV5F1-31 4(A), 2(B) port
VF133 stations
M5, 1/8

Individual EXH

5(EA), 3(EB) port 1(P) port


M5 x 0.8 1/8

VF3000 VV5F3-30 4(A), 2(B) port


1/8, 1/4
Body ported

5(R), 3(R) port VF330 2 to 20


Common EXH 1/4 VF333 stations
P. 27

1(P) port
1/4
VF5000 VV5F5-20 4(A), 2(B) port

5(R), 3(R) port 2 to 10


Common EXH 3/8 stations

1(P) port
3/8 VF520
VV5F5-21 4(A), 2(B) port VF523

5(R), 3(R) port 2 to 15


Common EXH 1/2 stations

1(P) port
1/2

VF3000 VV5F3-40
5(R), 3(R) port
1/4

VF340 2 to 20
Common EXH 1(P) port VF343 stations
1/4
Base mounted

4(A), 2(B) port


1/4
P. 39
VF5000 VV5F5-40 5(R), 3(R) port
3/8

2 to 10
Common EXH VF544
stations
1(P) port
3/8
4(A), 2(B) port
1/4

Features 2
VF-B.qxd 10.12.1 9:37 AM Page 4

Cylinder Speed Chart q


This chart is provided as guidelines only.
For performance under various conditions, use SMC’s
Model Selection Program before making a judgement.
Body Ported
Bore size
Series CJ2 Series CM2 Series MB, CA2 Series CS1
Average
Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series speed Load factor 50% Load factor 50% Load factor 50% Load factor 50%
(mm/s) Stroke 60 mm Stroke 300 mm Stroke 500 mm Stroke 1000 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
1000
800 Perpendicular,
upward actuation
600
VF1120-01 Horizontal actuation
400
200
0
1000
800
600
VF3130-02
400
200
0
1000
800
600
VF5120-03
400
200
0
∗ With : when using steel piping

Base Mounted
Bore size
Series CJ2 Series CM2 Series MB, CA2 Series CS1
Average
Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa Pressure 0.5 MPa
Series speed Load factor 50% Load factor 50% Load factor 50% Load factor 50%
(mm/s) Stroke 60 mm Stroke 300 mm Stroke 500 mm Stroke 1000 mm
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180 ø200
1000 Perpendicular,
800 upward actuation
600 Horizontal actuation
VF3140-03
400
200
0
1000
800
600
VF5144-04
400
200
0
∗ With : when using steel piping

Front matter 1
VF-B.qxd 10.12.1 9:37 AM Page 5

Cylinder Speed Chart w


This chart is provided as guidelines only.
For performance under various conditions, use SMC’s
Conditions Model Selection Program before making a judgement.

Body Ported
Body ported Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tube bore x Length T0604 x 1 m T0806 x 1 m —
VF1120-01 Speed controller AS3001F-06 AS3001F-08 —
Silencer AN101-01 —
Tube bore x Length T0604 x 1 m T1075 x 1 m —
VF3130-02 Speed controller AS3001F-06 AS4001F-10 —
Silencer AN110-01 —
Tube bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
VF5120-03 Speed controller AS3001F-06 AS4001F-10 AS4001F-12
Silencer AN200-02 AN202-02

Body Ported [when using SGP (Steel Piping)]


Body ported Series CS1
Tube bore x Length SGP10A x 1 m
VF5120-03 Speed controller AS420-03
Silencer AN200-02

Base Mounted
Base mounted Series CJ2 Series CM2 Series MB, CA2 Series CS1
Tube bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m —
VF3140-03 Speed controller AS3001F-06 AS4001F-10 AS4001F-12 —
Silencer AN200-02 —
Tube bore x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m
VF5144-04 Speed controller AS3001F-06 AS4001F-10 AS4001F-12
Silencer AN200-02

Base Mounted [when using SGP (Steel Piping)]


Base mounted Series CS1
Tube bore x Length SGP10A x 1 m
VF3140-03 Speed controller AS420-03
Silencer AN300-03
Tube bore x Length SGP15A x 1 m
VF5144-04 Speed controller AS420-04
Silencer AN400-04

Front matter 2
VF-B.qxd 10.12.1 9:37 AM Page 6

Pilot Operated 5 Port Solenoid Valve

Series VF1000/3000/5000
Body Ported Single Unit Note) Only DIN and conduit terminal types
are available with AC mode.
How to Order Valve Refer to the electrical entry for details.

Body ported VF 3 1 3 0 5 G 1 01
Series
1 VF1000 Type of actuation Bracket
3 VF3000 1 2-position single Nil Without bracket
Thread type
5 VF5000 2 2-position double F With bracket
Nil Rc
3 3-position closed center VF1000/3000
F G Single type
4 3-position exhaust center
N NPT (The bracket cannot be
5 3-position pressure center
T NPTF connected after
∗ Only 1 and 2 are available with the VF1000. delivered.)
∗ M5 is available
Body model with Nil only.
Symbol VF1000 VF3000 VF5000 Pressure specification
2  —  Nil Standard (0.7 MPa)
3 —  — K High-pressure type (1 MPa)

Body option Coil specification VF1000


0: Pilot valve individual exhaust Nil Standard Double type
T With power saving circuit (DC only) only
Note) Be sure to select the power saving circuit type
when it is continuously energized for long periods
of time. (Refer to back pages 5 and 6 for details.)
PE port∗ EA/EB port ∗ T type is available with DC mode only. When T is
VF1000 VF3000 VF5000 selected, only Z type of light/surge voltage suppressor
∗ Not available with the VF5000.
   is available. (Note that when the electrical entry of DIN
terminal type without connector is selected, only DOS
3: Main/Pilot valve common Made to Order
and YOS are available.)
exhaust Rated voltage Nil —
DC AC (50/60 Hz) Pilot exhaust port with piping thread (M3)
X500 specification (Refer to page 14).
5 24 VDC 1 100 VAC
PE port EA/EB port
6 12 VDC 2 200 VAC
3 110 VAC [115 VAC]
A, B port size
VF1000 VF3000 VF5000 Symbol Port size VF1000 VF3000 VF5000
4 220 VAC [230 VAC]
—   M5 M5 x 0.8  — —
7 240 VAC
∗ Refer to “Made to Order” (P.14) 01 1/8   —
when piping to PE port is required. B 24 VAC
02 1/4 —  
Electrical entry 03 3/8 — — 
L-type plug M-type plug DIN DIN (EN175301-803) Conduit
Grommet Manual override
connector connector terminal terminal terminal
Nil: Non-locking D: Push-turn locking E: Push-turn locking
[IP65 compatible] [IP65 compatible] [IP65 compatible] push type slotted type lever type

G: Lead wire L: With lead wire M: With lead wire


length 300 mm (length 300 mm) (length 300 mm)
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal
Light/surge voltage suppressor
Symbol Light/surge voltage suppressor DC AC
LN: MN: Nil Without light/surge voltage suppressor  
Without lead wire Without lead wire S With surge voltage suppressor  —
Note)

G: Lead wire
length 300 mm
Z With light/surge voltage suppressor  
H: Lead wire R With surge voltage suppressor (Non-polar)  —
length 600 mm U With light/surge voltage suppressor (Non-polar)  —
DC Note) There is no S option for AC mode, since a rectifier
Without light/ prevents surge voltage generation.
surge voltage LO: MO: DO: YO: ∗ In the DIN terminal type, since a light is installed in the con-
suppressor Without connector Without connector Without connector Without connector nector, DOZ, DOU, YOZ, YOU are not available.
CE DC
compliant AC Note 2) — — — Caution
∗ LN and MN types are with 2 sockets. When using the surge voltage suppressor
∗ Refer to back page 3 when different length of lead wire for L/M-type plug connector is required. type, residual voltage will remain. Refer to
∗ Refer to back page 4 for details on the DIN (EN175301-803) terminal.
back page 6 for details.
Note 1) When using with IP65, select the main/pilot valve common exhaust type. (Except VF1000)
Note 2) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking compliant.
1
VF-B.qxd 10.12.1 9:37 AM Page 7

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Specifications

Model VF1000 VF3000 VF5000


Fluid Air
Operating 2-position single/3-position 0.15 to 0.7
Series VF1000 Standard
pressure 2-position double 0.1 to 0.7
range High- 2-position single/3-position 0.15 to 1.0
pressure
(MPa) type 2-position double 0.1 to 1.0
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Max. operating 2-position single/double 10 10 5
Series VF3000 frequency (Hz) 3-position — 3 3
Non-locking push type
Manual override Push-turn locking slotted type
Push-turn locking lever type
Pilot exhaust type Individual exhaust, Main/Pilot valve common exhaust (Except VF1000)
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 300/50
Series VF5000
Enclosure Dustproof (IP65∗ for D, Y, T)
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the
main valve and armature in both energized and de-energized states every once for each
condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at
both energized and de-energized states in the axial direction and at the right angles to the
main valve and armature. (Values at the initial period)
∗ Based on IEC60529. When using with IP65, select the main/pilot valve common exhaust type.

Made to Order
(Refer to page 14 for details.)
Solenoid Specifications
Pilot exhaust port with piping
X500 Grommet (G), (H) DIN terminal (D)
thread (M3) specification
L-type plug connector (L) DIN (EN175301-803) terminal (Y)
Electrical entry M-type plug connector (M) Conduit terminal (T)
G, H, L, M D, Y, T
Coil rated DC 24, 12
voltage (V) AC (50/60 Hz) 24, 100, 110, 200, 220, 240
Allowable voltage fluctuation ±10%∗ of rated voltage
Power con- Standard 1.5 (With light: 1.55) 1.5 (With light: 1.75)
DC
sumption (W) With power saving circuit 0.55 (With light only) 0.75 (With light only)
24 V 1.5 (With light: 1.55) 1.5 (With light: 1.75)
100 V
Apparent 110 V [115 V]
AC 1.55 (With light: 1.65) 1.55 (With light: 1.7)
power (VA)∗ 200 V
220 V [230 V]
240 V
Surge voltage suppressor Diode (Non-polar type: Varistor)
Indicator light LED (Neon bulb is used for AC mode of D, Y, T.)
∗ It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
∗ Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable voltage
fluctuation should be within the following range.
24 VDC: –7% to +10% 12 VDC: –4% to +10%
Response Time

Response time ms (at 0.5 MPa)


Pressure Operating pressure
Series Type of actuation Without light/surge With light/surge voltage suppressor
specification range (MPa) AC
voltage suppressor S, Z type R, U type
Single 0.15 to 0.7 20 45 23 45
Standard
Double 0.1 to 0.7 12 12 12 12
VF1000 2-position
Single High-pressure 0.15 to 1.0 23 48 26 48
Double type 0.1 to 1.0 15 15 15 15
Single 0.15 to 0.7 20 45 23 45
2-position
Double Standard 0.1 to 0.7 12 12 12 12
3-position 0.15 to 0.7 30 55 33 55
VF3000
Single 0.15 to 1.0 23 48 26 48
2-position High-pressure
Double 0.1 to 1.0 15 15 15 15
type
3-position 0.15 to 1.0 33 58 36 58
Single 0.15 to 0.7 30 55 33 55
2-position
Double Standard 0.1 to 0.7 15 15 15 15
3-position 0.15 to 0.7 50 75 53 75
VF5000
Single 0.15 to 1.0 33 58 36 58
2-position High-pressure
Double 0.1 to 1.0 18 18 18 18
type
3-position 0.15 to 1.0 53 78 56 78
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage)
2
VF-B.qxd 10.12.1 9:37 AM Page 8

Series VF1000/3000/5000

Flow-rate Characteristics/Weight

Port size Flow-rate characteristics Note 1)


Weight (g) Note 2)
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Valve model Type of actuation 1, 4, 2 5, 3
(P, A, B) (EA, EB) C [dm3/ C [dm3/
(s/bar)] b Cv (s/bar)] b Cv Grommet DIN terminal

2- Single 0.49 0.40 0.13 0.52 0.35 0.13 140 176


VF120-M5 position M5 x 0.8
Double 0.49 0.40 0.13 0.52 0.35 0.13 200 272
2- Single 0.76 0.22 0.17 0.53 0.28 0.13 136 172
VF120-01 position 1/8 M5 x 0.8
Double 0.76 0.22 0.17 0.53 0.28 0.13 196 268
2- Single 3.0 0.38 0.78 2.8 0.30 0.67 182 218
position Double 3.0 0.38 0.78 2.8 0.30 0.67 243 315
Closed center 2.4 0.31 0.64 1.8 0.37 0.46 260 332
VF330-01 1/8 3.0 0.32 0.76
3- Exhaust center 2.6 0.37 0.70 260 332
[2.5] [0.28] [0.62]
position
3.0 0.42 0.83
Pressure center 2.4 0.27 0.59 260 332
[1.4] [0.44] [0.39]
2- Single 4.0 0.36 1.0 3.1 0.32 0.75 178 214
position Double 4.0 0.36 1.0 3.1 0.32 0.75 239 311
Closed center 2.4 0.45 0.68 1.9 0.37 0.47 256 328
VF330-02 1/4 1/8 3.1 0.36 0.79
3- Exhaust center 3.0 0.42 0.82 256 328
[2.7] [0.29] [0.66]
position
5.5 0.37 1.4
Pressure center 2.6 0.32 0.64 256 328
[1.4] [0.50] [0.40]
2- Single 7.1 0.46 1.9 7.7 0.51 2.2 313 349
position Double 7.1 0.46 1.9 7.7 0.51 2.2 368 440
Closed center 6.7 0.46 1.8 6.6 0.41 1.8 406 478
VF520-02 1/4 8.0 0.45 2.2
3- Exhaust center 7.1 0.42 1.9 406 478
[7.4] [0.47] [2.1]
position
6.8 0.51 2.0
Pressure center 5.7 0.37 1.4 406 478
[2.7] [0.50] [0.78]
2- Single 8.8 0.44 2.4 10.0 0.49 2.9 299 335
position Double 8.8 0.44 2.4 10.0 0.49 2.9 354 426
Closed center 7.5 0.43 2.0 7.5 0.38 1.9 391 463
VF520-03 3/8 10.0 0.48 3.0
3- Exhaust center 8.3 0.40 2.2 391 463
[8.7] [0.46] [2.4]
position
9.2 0.50 2.6
Pressure center 6.1 0.35 1.6 391 463
[3.0] [0.49] [0.85]
Note 1) [ ]: Normal position
Note 2) Values without bracket

3
VF-B.qxd 10.12.1 9:37 AM Page 9

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Construction/Body Ported
2-position single
VF1000 VF3000/5000
Symbol
2-position single
u wr u w t q e
VF1000 q e
(B) (A) (A) (B)
2 4 4 2
y
VF3000
VF5000 3 5
t
(EB) (EA)

1 5 1 3
Strainer (EA) (P) (EB)
(P)
r y

2-position double
Symbol
2-position double
u wr q u w t q
VF1000
(B) (A) (A) (B)
2 4 4 2

VF3000
VF5000
3 5
(EB) (EA)

1 5 1 3
(P) t r
(EA) (P) (EB)

3-position closed center/exhaust center/pressure center


u w t q
Symbol
3-position closed center (A) (B)
4 2

3-position exhaust center


5 1 3
(EA) (P) (EB)
r
(Drawing shows a closed center type.)
3-position pressure center

Component Parts
No. Description Material Note
1 Body Aluminum die-casted White
2 Adapter plate Resin Gray
3 End plate Aluminum die-casted (VF5000: Resin) White
4 Piston Resin
5 Spool valve Aluminum, HNBR
6 Spring Stainless steel

Replacement Parts
No. Description Part no. Note
7 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 5. Built-in strainer

Bracket Assembly Part No.


Description Part no.
Bracket (for VF1000 double) DXT144-8-1A (With 2 mounting screws)

4
356-VF-CT.qxd 11.1.12 5:02 PM Page 1

Series VF1000/3000/5000

How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.

Valve model: VF첸첸첸첸


∗ Select from the below in accordance with the valve used.
5 G Z 첸 1 첸첸첸
왎 Grommet or L/M-type

V2 11 5 G Z
Light/surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor 쑗 쑗
S With surge voltage suppressor 쑗 — Note)
Z With light/surge voltage suppressor 쑗 쑗
R With surge voltage suppressor (Non-polar) 쑗 —
V211
U With light/surge voltage suppressor (Non-polar) 쑗 —
Pilot valve assembly
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.

Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 6
for details.

Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to back page 3 when different length of
lead wire for L/M-type plug connector is required.

왎 DIN or Conduit type


DIN connector
(Refer to back page 4.) V2 12 5
Pressure specification Rated voltage
Nil Standard (0.7 MPa)
DC
K High-pressure type (1 MPa)
5 24 VDC
6 12 VDC
Coil specification
Nil Standard
AC (50/60 Hz)
T With power saving circuit (DC only) 1 100 VAC
∗ T type is available with DC mode only.
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
V212 7 240 VAC
Pilot valve assembly B 24 VAC

Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.

Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
5
VF-B.qxd 10.12.1 9:37 AM Page 11

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Series VF1000/Body Ported/Dimensions


2-position single
H 1-M5 (-F)
Grommet (G) (H): VF1120- G H 1-01 (-F)
Grommet (G) (H): VF1120- G
M5 x 0.8 1/8
[4(A), 2(B) port] 6 14.8 [4(A), 2(B) port] 11.5 12

(1
(11 tanc

6. tan en
(D etw

6) ce po
Manual override

(D
Manual override

b
is e
.7)
is

1.7
1.7

26.4

26.4
4A 4A

12
10

eb
2B 2B

rts
etw

)
ee
(1.6) (1.6)
G: Approx. 300 41.5 G: Approx. 300 41.5

np
H: Approx. 600 H: Approx. 600

ort
80 (6) 80 (6)

s)
(Lead wire length) (13 (Lead wire length)
.4)
(D
(Indicator light) bet istan
we ce
en
por
ts)
- +
44.5

5EA

(45)
(55)
35
14.5 6
21.5

17.5
3EB

M5 x 0.8
[5(EA), 3(EB) port] 12 11.8 2 x ø5.5 (16)
(For mounting)
(26)
ø2.3 M5 x 0.8, 1/8
1.3

(PE port) [1(P) port]


1P
Grommet (G) (H)
DC without light/surge voltage suppressor
17.8
43.4
10 12.8
2 x M4 x 0.7 thread depth 5 5EA

(For mounting)
15.8

3EB

G: Approx. 300
12.5

H: Approx. 600 81.2


(Lead wire length)

01  (-F) DIN terminal (D) (Y): VF1120- Y 1- 01  (-F)


L-type plug connector (L): VF1120-L1- M5 D M5

Max. 10 86.8
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 86.3
(Lead wire length)
Pg9
84.5

5EA
75.5
21.8

3EB

5EA

3EB

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

01  (-F) Conduit terminal (T): VF1120-T1- 01  (-F)


M-type plug connector (M): VF1120-M1- M5 M5
(Lead wire length)

Max. 10 89.2
Approx. 300

77.9 Applicable cable O.D.


(Indicator light)
ø4.5 to ø7
72.8

Pg9
88.7 [78.7]
78.7 [68.7]
55.5

5EA 5EA

3EB 3EB

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
6
VF-B.qxd 10.12.1 9:37 AM Page 12

Series VF1000/3000/5000

Series VF1000/Body Ported/Dimensions


2-position double
H 1-M5
Grommet (G) (H): VF1220- G H 1-01
Grommet (G) (H): VF1220- G
1/8 (D 16 (

(Di betw orts)


M5 x 0.8
be stan .6)
i

(1
sta een
1.7
[4(A), 2(B) port] [4(A), 2(B) port] tw ce

nce
po een

(4)
Manual override Manual override rts
)
1.7

1.7
26.4

26.4
12
4A 4A

10
2B 2B

1.7
1.7
6 11.5
G: Approx. 300 47.5 G: Approx. 300 47.5
H: Approx. 600 124.4 H: Approx. 600 124.4
(Lead wire length) (Lead wire length)
bet ( (1
(Indicator light) we Dista 3.4)
en nce
por
ts)

- +
44.5

5EA
6
21.5

3EB
14.5

M5 x 0.8 12
(5.5)

[5(EA), 3(EB) port] (40) 2 x ø4.5


(50) (For mounting)

2 x ø2.3 M5 x 0.8, 1/8


[1(P) port]
Grommet (G) (H)
1.3

(PE port)
1P
DC without light/surge voltage suppressor
1.3

51.3
10
12.5

3EB
15.8

5EA

G: Approx. 300
2 x M4 x 0.7 thread depth 5 H: Approx. 600 126.8
(For mounting bracket) (Lead wire length)

01 
L-type plug connector (L): VF1220-L1- M5 DIN terminal (D) (Y): VF1220- DY 1- M5
01 
Max. 10 138.1
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 137.1
(Lead wire length)
Pg9
84.5

5EA
75.5
21.8

3EB

5EA

3EB

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

01  Conduit terminal (T): VF1220-T1- 01 


M-type plug connector (M): VF1220-M1- M5 M5
(Lead wire length)
Approx. 300

Max. 10 142.9
120.3 Applicable cable O.D.
(Indicator light)
110.1 ø4.5 to ø7

Pg9
88.7 [78.7]
78.7 [68.7]
55.5

5EA 5EA

3EB 3EB

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
7
VF-B.qxd 10.12.1 9:37 AM Page 13

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Series VF3000/Body Ported/Dimensions


2-position single
H 1- 02  (-F)
Grommet (G) (H): VF3130- G 01

1/8, 1/4
[4(A), 2(B) port] 10 25.5 2 x ø4.3
Manual override (For mounting)
1.7

4A 2B

26.4
20
23 19
(1.6)
G: Approx. 300 67
H: Approx. 600 105.5 (6)
(Lead wire length)

(Indicator light)

(10)
- +
44.5

(45)
(55)
31.5
35
21.5

17.5
7

2 x ø4.2 20.5 20.3


(For mounting) 2 x ø5.5 (16)
(For mounting)
1/8, 1/4
(26) Grommet (G) (H)
(18.4)
(18.4)
DC without light/surge voltage suppressor
[1(P) port] (Distan
1/8 ce betw
[5(EA), 3(EB) port] een po
rts)
1.3

3EB
8

15.8

5EA
1P
G: Approx. 300
ø2.3 36 12.5 H: Approx. 600 106.7
(PE port) 30.5 (Lead wire length)
68.9

02  (-F) DIN terminal (D) (Y): VF3130- Y 1- 02  (-F)


L-type plug connector (L): VF3130-L1- 01 D 01

Max. 10 112.3
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 111.8
(Lead wire length)

Pg9
84.5
75.5
21.8

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

02  (-F) Conduit terminal (T): VF3130-T1- 02  (-F)


M-type plug connector (M): VF3130-M1- 01 01
(Lead wire length)

Max. 10 114.7
Approx. 300

103.4 Applicable cable O.D. (Indicator light)


ø4.5 to ø7
98.3
88.7 [78.7]

Pg9
78.7 [68.7]
55.5

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
8
VF-B.qxd 10.12.1 9:37 AM Page 14

Series VF1000/3000/5000

Series VF3000/Body Ported/Dimensions


2-position double
H 1- 02 
Grommet (G) (H): VF3230- G 01

1/8, 1/4
[4(A), 2(B) port] 23 2 x ø4.3
Manual override 10 (For mounting)
1.7

4A 2B

26.4
20
1

1.7
73
G: Approx. 300
H: Approx. 600 149.9
(Lead wire length)

(Indicator light)

- +
44.5
31.5
21.5

2 x ø4.2 20.5
(For mounting)
Grommet (G) (H)
1/8, 1/4
DC without light/surge voltage suppressor
[1(P) port] (18.4)
1/8 (Distan (18.4)
[5(EA), 3(EB) port] ce betw
een po
rts)
1.3

3EB
15.8

5EA
1P

G: Approx. 300
8

1.3

2 x ø2.3
36 H: Approx. 600 152.3
(PE port)
76.8 (Lead wire length)

02 
L-type plug connector (L): VF3230-L1- 01 DIN terminal (D) (Y): VF3230- DY 1- 01
02 
Max. 10 163.6

Applicable cable O.D.


ø4.5 to ø7
Approx. 300 162.6
(Lead wire length)

Pg9
84.5
75.5
21.8

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

02  Conduit terminal (T): VF3230-T1- 02 


M-type plug connector (M): VF3230-M1- 01 01
(Lead wire length)

Max. 10 168.4
Approx. 300

145.8 Applicable cable O.D.


(Indicator light)
ø4.5 to ø7
135.6
88.7 [78.7]
78.7 [68.7]

Pg9
55.5

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
9
VF-B.qxd 10.12.1 9:37 AM Page 15

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Series VF3000/Body Ported/Dimensions


3-position closed center/exhaust center/pressure center
3
H 1- 02 
Grommet (G) (H): VF3 4 30- G 01
5
1/8, 1/4
[4(A), 2(B) port] 23
2 x ø4.3
Manual override 10 (For mounting)
1.7

4A 2B

26.4
20
1

1.7
36.5 52.5

G: Approx. 300 75
H: Approx. 600 165.9
(Lead wire length)

(Indicator light)

- +
44.5
31.5
21.5

2 x ø4.2 20.5
(For mounting) Grommet (G) (H)
1/8, 1/4 DC without light/surge voltage suppressor
[1(P) port] (18.4)
(18.4)
1/8 (Distan
ce betw
[5(EA), 3(EB) port] een po
rts)
1.3

3EB
15.8

5EA
1P
1.3
8

2 x ø2.3 36 76.2
G: Approx. 300
(PE port) 38.4 54.4 H: Approx. 600 168.3
(Lead wire length)

3 3
02 
L-type plug connector (L): VF3 4 30-L1- 01
5
DIN terminal (D) (Y): VF3 4 30- DY 1- 01
02  5
Max. 10 179.6
Applicable cable O.D.
81.8
Approx. 300 178.6 ø4.5 to ø7
(Lead wire
length) 81.3

Pg9
84.5
75.5
21.8

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

3 3
02  Conduit terminal (T): VF3 4 30-T1- 02 
M-type plug connector (M): VF3 4 30-M1- 01 01
5 5
(Lead wire length)

Max. 10 184.4
Approx. 300

161.8
Applicable cable O.D. 84.2
72.9 ø4.5 to ø7 (Indicator light)
67.8 83.8
88.7 [78.7]

Pg9
78.7 [68.7]
55.5

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
10
VF-B.qxd 10.12.1 9:37 AM Page 16

Series VF1000/3000/5000

Series VF5000/Body Ported/Dimensions


2-position single
H 1- 03 
Grommet (G) (H): VF5120- G 02

G: Approx. 300
H: Approx. 600 142.2
(Lead wire length) 103.7
44 28.5
(28.2)
(Distance be
tween ports)
2B

3
24
32
1.2

4A
Manual override
1/4, 3/8
2 x ø4.3 28 36.5
[4(A), 2(B) port]
(For mounting)

(Indicator light) 50.5

- +
36
45
40
22

Grommet (G) (H)


4.5

3 x ø4.3 27 37
(For mounting) DC without light/surge voltage suppressor
1/4, 3/8 G: Approx. 300
[1(P), 5(EA), 3(EB) port] H: Approx. 600 143.4
52 (Lead wire length)
0.4

3EB
16.3

5EA 1P
ø2.3 50.5
(PE port)
100.8

03 
L-type plug connector (L): VF5120-L1- 02 DIN terminal (D) (Y): VF5120- DY 1- 02
03 
Max. 10 149
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 148.5
(Lead wire length)

Pg9
85
76
22.3

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

03  Conduit terminal (T): VF5120-T1- 03 


M-type plug connector (M): VF5120-M1- 02 02
(Lead wire length)

Max. 10 151.4
Approx. 300

140.1 Applicable cable O.D.


ø4.5 to ø7
135
(Indicator light)

Pg9
89.2 [79.2]
79.2 [69.2]
56

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
11
VF-B.qxd 10.12.1 9:37 AM Page 17

Pilot Operated 5 Port Solenoid Valve


Body Ported/Single Unit Series VF1000/3000/5000

Series VF5000/Body Ported/Dimensions


2-position double
H 1- 03 
Grommet (G) (H): VF5220- G 02

G: Approx. 300
H: Approx. 600 183.3
(Lead wire length)
106.4
(28.2)
(Distance be
tween ports)

1.2
3
2B

24
32
1.2

4A
Manual override
28 1/4, 3/8
2 x ø4.3 44 [4(A), 2(B) port]
(For mounting)
(Indicator light)

- +
36
45
40
22

4.5

3 x ø4.3 27 Grommet (G) (H)


(For mounting) DC without light/surge voltage suppressor
1/4, 3/8 G: Approx. 300
H: Approx. 600 185.7
[1(P), 5(EA), 3(EB) port]
(Lead wire length)
52
0.4

3EB
16.3

5EA 1P
0.4

2 x ø2.3
100.6
(PE port)

03 
L-type plug connector (L): VF5220-L1- 02 DIN terminal (D) (Y): VF5220- DY 1- 02
03 
Max. 10 197
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 196
(Lead wire
length)
Pg9
85
76
22.3

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

03  Conduit terminal (T): VF5220-T1- 03 


M-type plug connector (M): VF5220-M1- 02 02
(Lead wire length)

Max. 10 201.8
Approx. 300

179.2 Applicable cable O.D.


169 ø4.5 to ø7

(Indicator light)

Pg9
89.2 [79.2]
79.2 [69.2]
56

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
12
VF-B.qxd 10.12.1 9:37 AM Page 18

Series VF1000/3000/5000

Series VF5000/Body Ported/Dimensions


3-position closed center/exhaust center/pressure center
3
H 1- 03 
Grommet (G) (H): VF5 4 20- G 02
5
G: Approx. 300
H: Approx. 600 202.3
(Lead wire length) 91.7
53.2 72.2
(28.2)
(Distance be
tween ports

1.2
)
3
2B

24
32
1.2

4A
Manual override
28 1/4, 3/8
2 x ø4.3 [4(A), 2(B) port]
44
(For mounting)
(Indicator light)

- +
36

45
40
22

Grommet (G) (H)


4.5

3 x ø4.3 27
(For mounting) DC without light/surge voltage suppressor
G: Approx. 300
1/4, 3/8 H: Approx. 600 204.7
[1(P), 5(EA), 3(EB) port] (Lead wire length) 92.9
52
0.4

3EB
16.3

5EA 1P
0.4

2 x ø2.3
(PE port) 50.3 69.3

3 3
L-type plug connector (L): VF5 4 20-L1- 02
03 DIN terminal (D) (Y): VF5 4 20- DY 1- 02
03 
5 5
Max. 10 216
98.5
Applicable cable O.D.
Approx. 300 215 ø4.5 to ø7
(Lead wire
98
length)
Pg9
85
76
22.3

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

3 3
03 
M-type plug connector (M): VF5 4 20-M1- 02
5 03 
Conduit terminal (T): VF5 4 20-T1- 02
5
(Lead wire length)

Max. 10 220.8
198.2
Approx. 300

Applicable cable O.D. 100.9


89.6
ø4.5 to ø7 (Indicator light)
84.5 103.5

Pg9
89.2 [79.2]
79.2 [69.2]
56

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
13
VF-B.qxd 10.12.1 9:37 AM Page 19

Series VF1000/3000/5000
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.

1 Body Ported Pilot Exhaust Port with Piping Thread (M3) Specification
In this specification, piping to the pilot exhaust port (PE port) is available when the valve is used in an environment where the
exhaust from the pilot valve is not allowable, or intrusion of ambient dust should be prevented.

How to Order Valve

VF 3 30 1 X500
Series
1 VF1000
3 VF3000 Entry is the same as standard products.
5 VF5000 The specifications and performance are the same as those of standard models.

Type of actuation Body model


1 2-position single Symbol VF1000 VF3000 VF5000
2 2-position double 2  — 
3 3-position closed center 3 —  —
4 3-position exhaust center
5 3-position pressure center

• 2-position single Pilot exhaust port (PE port)


M3 x 0.5
L2

3EB

5EA
1P

L1

• 2-position double
L2

3EB

5EA
1P
L2

L3

• 3-position closed center/exhaust center/pressure center


L2

3EB

5EA
1P
L2

L4 L5

Series L1 L2 L3 L4 L5
VF1000 34.5 4.2 33.4 — —
VF3000 60 4.2 59 29.5 45.5
VF5000 95 3.45 89 44.5 63.5
14
VF-B.qxd 10.12.1 9:37 AM Page 20

Pilot Operated 5 Port Solenoid Valve

Series VF3000/5000
Base Mounted Single Unit Note) Only DIN and conduit terminal types
are available with AC mode.
How to Order Valve Refer to the electrical entry for details.

Base mounted
(VF1000: Not available) VF 3 1 4 0 K T 5 G Z D 1 02
Series Thread type
3 VF3000 Nil Rc
Type of actuation F G
5 VF5000
1 2-position single N NPT
∗ Not available
2 2-position double T NPTF
with the VF1000.
3 3-position closed center
4 3-position exhaust center Port size (Sub-plate)
5 3-position pressure center Symbol Port size VF3000 VF5000
Nil Without sub-plate
Body model
02 1/4  
Body option 03 3/8  
0: Pilot valve individual exhaust Pressure specification 04 1/2 — 
Nil Standard (0.7 MPa) ∗ Without the sub-plate, two mounting
K High-pressure type (1 MPa) screws and gasket are accompanied.
Manual override
PE port EA/EB port Coil specification
Nil: Non-locking D: Push-turn locking E: Push-turn locking
VF3000 VF5000 Nil Standard
push type slotted type lever type
 — T With power saving circuit (DC only)
3: Main/Pilot valve common Note) Be sure to select the power saving circuit type
exhaust when it is continuously energized for long periods
of time. (Refer to back pages 5 and 6 for details.)
∗ T type is available with DC mode only. When T is
selected, only Z type of light/surge voltage suppressor
is available. (Note that when the electrical entry of DIN
PE port EA/EB port terminal type without connector is selected, only DOS
VF3000 VF5000 and YOS are available.)
 — Rated voltage
4: Pilot valve base exhaust Light/surge voltage suppressor
DC AC (50/60 Hz) Symbol Light/surge voltage suppressor DC AC
5 24 VDC 1 100 VAC Nil Without light/surge voltage suppressor  
PE port 6 12 VDC 2 200 VAC S With surge voltage suppressor  —Note)
3 110 VAC [115 VAC] Z With light/surge voltage suppressor  
VF3000 VF5000 4 220 VAC [230 VAC] R With surge voltage suppressor (Non-polar)  —
—  7 240 VAC U With light/surge voltage suppressor (Non-polar)  —
B 24 VAC Note) There is no S option for AC mode, since a rectifier
prevents surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the con-
Electrical entry nector, DOZ, DOU, YOZ, YOU are not available.
L-type plug M-type plug DIN DIN (EN175301-803) Conduit
Grommet
connector connector terminal terminal terminal
Caution
[IP65 compatible] [IP65 compatible] [IP65 compatible]
When using the surge voltage suppressor
type, residual voltage will remain. Refer to
back page 6 for details.

G: Lead wire L: With lead wire M: With lead wire


length 300 mm (length 300 mm) (length 300 mm)
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal

LN: MN:
Without lead wire Without lead wire
G: Lead wire
length 300 mm
H: Lead wire ∗ LN and MN types are with 2 sockets.
length 600 mm ∗ Refer to back page 3 when different length of lead wire for L/M-
DC type plug connector is required.
Without light/ ∗ Refer to back page 4 for details on the DIN (EN175301-803)
surge voltage LO: MO: DO: YO: terminal.
suppressor Without connector Without connector Without connector Without connector Note 1) When using with IP65, select the main/pilot valve common
exhaust type or pilot valve base exhaust type.
CE DC Note 2) With the same specifications as the DC type, all lead wire
compliant AC Note 2) — — — entries for the 24 VAC type are CE marking compliant.
15
VF-B.qxd 10.12.1 9:37 AM Page 21

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Single Unit Series VF3000/5000

Specifications

Model VF3000 VF5000


Fluid Air
Operating 2-position single/3-position 0.15 to 0.7
Standard
pressure 2-position double 0.1 to 0.7
range High- 2-position single/3-position 0.15 to 1.0
pressure
(MPa) type 2-position double 0.1 to 1.0
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Series VF3000 Max. operating 2-position single/double 10 5
frequency (Hz) 3-position 3 3
Non-locking push type
Manual override Push-turn locking slotted type
Push-turn locking lever type
Individual exhaust, Main/ Pilot valve
Pilot exhaust type
Pilot valve common exhaust base exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 300/50
Enclosure Dustproof (IP65∗ for D, Y, T)
Series VF5000
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the
main valve and armature in both energized and de-energized states every once for each
condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at
both energized and de-energized states in the axial direction and at the right angles to the
main valve and armature. (Values at the initial period)
∗ Based on IEC60529. When using with IP65, select the main/pilot valve common exhaust type or pilot valve base exhaust type.

Solenoid Specifications

Grommet (G), (H) DIN terminal (D)


L-type plug connector (L) DIN (EN175301-803) terminal (Y)
Electrical entry M-type plug connector (M) Conduit terminal (T)
G, H, L, M D, Y, T
Coil rated DC 24, 12
voltage (V) AC (50/60 Hz) 24, 100, 110, 200, 220, 240
Allowable voltage fluctuation ±10%∗ of rated voltage
Power con- Standard 1.5 (With light: 1.55) 1.5 (With light: 1.75)
DC
sumption (W) With power saving circuit 0.55 (With light only) 0.75 (With light only)
24 V 1.5 (With light: 1.55) 1.5 (With light: 1.75)
100 V
Apparent 110 V [115 V]
AC
power (VA)∗ 200 V 1.55 (With light: 1.65) 1.55 (With light: 1.7)
220 V [230 V]
240 V
Surge voltage suppressor Diode (Non-polar type: Varistor)
Indicator light LED (Neon bulb is used for AC mode of D, Y, T.)
∗ It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
∗ Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable voltage
fluctuation should be within the following range.
Response Time 24 VDC: –7% to +10% 12 VDC: –4% to +10%

Response time ms (at 0.5 MPa)


Pressure Operating pressure
Series Type of actuation Without light/surge With light/surge voltage suppressor
specification range (MPa) AC
voltage suppressor S, Z type R, U type
Single 0.15 to 0.7 20 45 23 45
Standard
Double 0.1 to 0.7 12 12 12 12
VF1000 2-position
Single High-pressure 0.15 to 1.0 23 48 26 48
Double type 0.1 to 1.0 15 15 15 15
Single 0.15 to 0.7 20 45 23 45
2-position
Double Standard 0.1 to 0.7 12 12 12 12
3-position 0.15 to 0.7 30 55 33 55
VF3000
Single 0.15 to 1.0 23 48 26 48
2-position High-pressure
Double 0.1 to 1.0 15 15 15 15
type
3-position 0.15 to 1.0 33 58 36 58
Single 0.15 to 0.7 30 55 33 55
2-position
Double Standard 0.1 to 0.7 15 15 15 15
3-position 0.15 to 0.7 50 75 53 75
VF5000
Single 0.15 to 1.0 33 58 36 58
2-position High-pressure
Double 0.1 to 1.0 18 18 18 18
type
3-position 0.15 to 1.0 53 78 56 78
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at rated voltage)
16
VF-B.qxd 10.12.1 9:37 AM Page 22

Series VF3000/5000

Flow-rate Characteristics/Weight

Flow-rate characteristics Note 1)


Weight (g) Note 2)
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → EA/EB)
Valve model Type of actuation Port size
C [dm3/ C [dm3/
(s/bar)] b Cv (s/bar)] b Cv Grommet DIN terminal

2- Single 2.8 0.14 0.64 2.5 0.18 0.57 344 (192) 380 (228)
position Double 2.8 0.14 0.64 2.5 0.18 0.57 405 (252) 477 (324)
Closed center 2.1 0.22 0.49 1.6 0.26 0.41 422 (270) 494 (342)
VF340-02 1/4 2.8 0.23 0.66
3- Exhaust center 2.3 0.21 0.53 422 (270) 494 (342)
[2.1] [0.26] [0.50]
position
2.9 0.16 0.67
Pressure center 2.1 0.23 0.49 422 (270) 494 (342)
[1.1] [0.45] [0.32]
2- Single 3.1 0.24 0.76 2.6 0.23 0.62 327 (192) 363 (228)
position Double 3.1 0.24 0.76 2.6 0.23 0.62 388 (252) 460 (324)
Closed center 2.2 0.33 0.57 1.6 0.34 0.40 405 (270) 477 (342)
VF340-03 3/8 2.8 0.30 0.68
3- Exhaust center 2.6 0.27 0.61 405 (270) 477 (342)
[2.3] [0.28] [0.55]
position
3.4 0.29 0.80
Pressure center 2.2 0.31 0.52 405 (270) 477 (342)
[1.3] [0.48] [0.38]
2- Single 7.3 0.49 2.1 7.3 0.50 2.0 486 (297) 522 (333)
position Double 7.3 0.49 2.1 7.3 0.50 2.0 541 (352) 613 (424)
Closed center 6.6 0.35 1.7 6.3 0.31 1.6 578 (390) 650 (462)
VF544-02 1/4 8.1 0.35 2.1
3- Exhaust center 7.4 0.33 1.9 578 (390) 650 (462)
[7.4] [0.34] [1.9]
position
8.0 0.35 2.1
Pressure center 5.6 0.31 1.5 578 (390) 650 (462)
[2.9] [0.48] [0.85]
2- Single 8.4 0.34 2.2 8.9 0.29 2.3 473 (297) 509 (333)
position Double 8.4 0.34 2.2 8.9 0.29 2.3 529 (352) 601 (424)
Closed center 7.3 0.34 2.0 7.1 0.28 1.8 566 (390) 638 (462)
VF544-03 3/8 14.0 0.26 3.4
3- Exhaust center 8.1 0.27 2.0 566 (390) 638 (462)
[8.3] [0.31] [2.2]
position
8.1 0.33 2.0
Pressure center 5.7 0.31 1.4 566 (390) 638 (462)
[2.5] [0.48] [0.74]
2- Single 9.4 0.43 2.7 12.0 0.32 3.0 545 (297) 581 (333)
position Double 9.4 0.43 2.7 12.0 0.32 3.0 600 (352) 672 (424)
Closed center 7.1 0.41 2.1 7.4 0.32 2.0 638 (390) 710 (462)
VF544-04 1/2 13.0 0.21 3.1
3- Exhaust center 8.6 0.39 2.4 638 (390) 710 (462)
[8.9] [0.40] [2.5]
position
11.0 0.18 2.6
Pressure center 6.1 0.35 1.6 638 (390) 710 (462)
[2.6] [0.47] [0.78]
Note 1) [ ]: Normal position
Note 2) Values without bracket

17
VF-B.qxd 10.12.1 9:37 AM Page 23

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Single Unit Series VF3000/5000

Construction/Base Mounted
VF3000/5000 t q e y
u w r
Symbol 2-position single
2-position single

Strainer
5 4 1 2 3
i (EA) (A) (P) (B) (EB)

u w r t q
Symbol 2-position double
2-position double

o
i 5 4 1 2 3
(EA) (A) (P) (B) (EB)

Symbol
3-position closed center 3-position closed center/exhaust center/pressure center
u w r t q

3-position exhaust center

3-position pressure center


o
i 5
(EA)
4
(A)
1
(P)
2
(B)
3
(EB)

(Drawing shows a closed center type.)

Sub-plate part no.

Component Parts VF 3 000 71 1


No. Description Material Note Series Thread type
1 Body Aluminum die-casted White 3 VF3000 Nil Rc
2 Adapter plate Resin Gray 5 VF5000 F G
Aluminum die-casted N NPT
3 End plate White Port size
(VF5000: Resin) T NPTF
4 Piston Resin Symbol Port size VF3000 VF5000

5
1 1/4  
Spool valve Aluminum, HNBR
2 3/8  
6 Spring Stainless steel
3 1/2 — 
Replacement Parts
Part no.
No. Description Note
VF3000 VF5000
7 Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 19. Built-in strainer
8 Gasket DXT031-30-11 DXT156-9-8 HNBR
1/4: VF5000-71-1
1/4: VF3000-71-1 Aluminum
9 Sub-plate 3/8: VF5000-71-2
3/8: VF3000-71-2 die-casted
1/2: VF5000-71-3
Round head combination DXT031-44-1 For valve
Caution
— —
screw (1 pc.) (With M4 x 39.5 SW) mounting Tightening Torque of
Hexagon socket head AXT620-32-1 For valve Valve Mounting
— —
cap screw (1 pc.) (With M4 x 48 SW) mounting M4: 1.4 N·m
18
356-VF-CT.qxd 11.1.12 5:02 PM Page 2

Series VF3000/5000

How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.

Valve model: VF첸첸첸첸


∗ Select from the below in accordance with the valve used.
5 G Z 첸1 첸첸첸
왎 Grommet or L/M-type

V2 11 5 G Z
Light/surge voltage suppressor DC AC
Nil Without light/surge voltage suppressor 쑗 쑗
S With surge voltage suppressor 쑗 — Note)
Z With light/surge voltage suppressor 쑗 쑗
R With surge voltage suppressor (Non-polar) 쑗 —
V211
U With light/surge voltage suppressor (Non-polar) 쑗 —
Pilot valve assembly
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.

Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 6
for details.

Electrical entry
G Grommet (Lead wire length 300 mm)
H Grommet (Lead wire length 600 mm)
L With lead wire
L-type plug
LN connector
Without lead wire
LO Without connector
M With lead wire
M-type plug
MN connector
Without lead wire
MO Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to back page 3 when different length of
lead wire for L/M-type plug connector is required.

왎 DIN or Conduit type


DIN connector
(Refer to back page 4.) V2 12 5
Pressure specification Rated voltage
Nil Standard (0.7 MPa)
DC
K High-pressure type (1 MPa)
5 24 VDC
6 12 VDC
Coil specification
Nil Standard
AC (50/60 Hz)
T With power saving circuit (DC only) 1 100 VAC
∗ T type is available with DC mode only.
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
V212 7 240 VAC
Pilot valve assembly B 24 VAC

Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.

Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
19
VF-B.qxd 10.12.1 9:37 AM Page 25

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Single Unit Series VF3000/5000

Series VF3000/Base Mounted/Dimensions


2-position single
H 1- 03 
Grommet (G) (H): VF3140- G 02

1/4, 3/8 28 33
[4(A), 2(B) port]

13
22
84.5
50 Manual 36 20
override
1.7

4A 2B

5EA

26.4
35
42
- +

3EB

5EA 1P 3EB

(Indicator light) G: Approx. 300


Grommet (G) (H)
H: Approx. 600 123 DC without light/surge voltage suppressor
(Lead wire length)
2 x ø4.3 G: Approx. 300
(For mounting) H: Approx. 600 124.2
(Lead wire length)
73

63.5

44.3
PE port
27
22
13

1/4, 3/8 25 25
[1(P), 5(EA), 3(EB) port] 43
81

03 
L-type plug connector (L): VF3140-L1- 02 DIN terminal (D) (Y): VF3140- DY 1- 02
03 
Max. 10 129.8
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 129.3
(Lead wire length)
Pg9
113
104
50.3

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

03  Conduit terminal (T): VF3140-T1- 03 


M-type plug connector (M): VF3140-M1- 02 02
(Lead wire length)

Max. 10 132.2
Approx. 300

Applicable cable O.D. (Indicator light)


120.9
ø4.5 to ø7
115.8

Pg9
117.2 [107.2]
107.2 [97.2]
84

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
20
VF-B.qxd 10.12.1 9:37 AM Page 26

Series VF3000/5000

Series VF3000/Base Mounted/Dimensions


2-position double
H 1- 03 
Grommet (G) (H): VF3240- G 02

1/4, 3/8 28 33
[4(A), 2(B) port]

13
22
50 Manual 36 20
override
1.7

4A 2B

5EA

26.4
35
42
- +

3EB

5EA 1P 3EB 1.7


(Indicator light) 2 x ø4.3
(For mounting)
73 11.5 Grommet (G) (H)
G: Approx. 300 27 DC without light/surge voltage suppressor
H: Approx. 600 149.9
(Lead wire length) G: Approx. 300
H: Approx. 600 152.3
(Lead wire length)
73

44.3

2 x PE port
27
22
13

28.2
1/4, 3/8 25 25
[1(P), 5(EA), 3(EB) port] 43
81

03 
L-type plug connector (L): VF3240-L1- 02 DIN terminal (D) (Y): VF3240- DY 1- 02
03 
Max. 10 163.6
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 162.6
(Lead wire length)
Pg9
113
104
50.3

33.3

33.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

03  Conduit terminal (T): VF3240-T1- 03 


M-type plug connector (M): VF3240-M1- 02 02
(Lead wire length)

Max. 10 168.4
Approx. 300

Applicable cable O.D.


145.8 ø4.5 to ø7 (Indicator light)

115.8 19.8

Pg9
117.2 [107.2]

107.2 [97.2]
84

36.2
24.9 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
21
VF-B.qxd 10.12.1 9:37 AM Page 27

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Single Unit Series VF3000/5000

Series VF3000/Base Mounted/Dimensions


3-position closed center/exhaust center/pressure center
3
Grommet (G) (H): VF3 4 40- G
H 1- 03 
02
5

1/4, 3/8 28 33
[4(A), 2(B) port]

13
22
50 Manual 36 20
override
1.7

4A 2B

5EA

26.4
35
42
– +

3EB

5EA 1P 3EB

(Indicator light) 2 x ø4.3 1.7


(For mounting)
84.5 4.5 Grommet (G) (H)
G: Approx. 300 43 DC without light/surge voltage suppressor
H: Approx. 600 165.9
G: Approx. 300
(Lead wire length) H: Approx. 600 168.3
(Lead wire length)
73

44.3

2 x PE port
27
22
13

1/4, 3/8 44.2


25 25
[1(P), 5(EA), 3(EB) port]
43
81

3 3
L-type plug connector (L): VF3 4 40-L1- 02
03  DIN terminal (D) (Y): VF3 4 40- DY 1- 02
03 
5 5
Max. 10 179.6
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 178.6
(Lead wire length)
Pg9
113

104
50.3

49.3

49.8
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).

3 3
M-type plug connector (M): VF3 4 40-M1- 02
03  Conduit terminal (T): VF3 4 40-T1- 03 
02
5 5
(Lead wire length)
Approx. 300

Max. 10 184.4
Applicable cable O.D.
161.8 ø4.5 to ø7
115.8 35.8 (Indicator light)

Pg9
117.2 [107.2]

107.2 [97.2]
84

40.9 52.2
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
22
VF-B.qxd 10.12.1 9:37 AM Page 28

Series VF3000/5000

Series VF5000/Base Mounted/Dimensions


2-position single 02
Grommet (G) (H): VF5144- G
H 1- 03
04

1/4, 3/8, 1/2

(15.5)
27 36
[4(A), 2(B) port]

14
(31) (40)
20.5
(24.5)

(Indicator light)

51 2 x ø5.3 (2 x ø6.5) 82 5
(55) (For mounting) (87) (6.5)
Manual override 4A 2B

(45)

(58)
42

52
- +

4A

2B
PE

1.2
6.5

5EA 1P 3EB
Grommet (G) (H)
22.5 103.7
G: Approx. 300 DC without light/surge voltage suppressor
(26.5) H: Approx. 600 142.2 G: Approx. 300
2 x M5 x 0.8 (Lead wire length) H: Approx. 600 143.4
(PE port) (Lead wire length)
(15.5)

(78)
74
14

(49.3)
45.3
(32.5)
28.5

30 30
(31) (31) 1/4, 3/8, 1/2
50 [1(P), 5(EA), 3(EB) port]
(54)
92 4.5
The dimensions in ( ) are for 1/2 piping port size. (100) (0.5)

02 02
L-type plug connector (L): VF5144-L1- 03  DIN terminal (D) (Y): VF5144- DY 1- 03 
04 04
Max. 10 149
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 148.5
(Lead wire length)
Pg9
(118)
114

(109)
105
(55.3)
51.3

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.

02 02
M-type plug connector (M): VF5144-M1- 03  Conduit terminal (T): VF5144-T1- 03 
04 04
Approx. 300
(Lead wire length)

Max. 10 151.4
Applicable cable O.D.
140.1 ø4.5 to ø7
135
(Indicator light)
Pg9
(112.2 [102.2])
(122.2 [112.2])
118.2 [108.2]

108.2 [98.2]
(89)
85

Unless otherwise indicated, dimensions are the same as Grommet (G).


Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: Without indicator light
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
23
VF-B.qxd 10.12.1 9:37 AM Page 29

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Single Unit Series VF3000/5000

Series VF5000/Base Mounted/Dimensions


2-position double
02
H 1- 03 
Grommet (G) (H): VF5244- G
04
1/4, 3/8, 1/2
27 36

(15.5)
[4(A), 2(B) port]
(31) (40)

14
20.5
(24.5)

(Indicator light)
2 x ø5.3 (2 x ø6.5)
51 82 5
(For mounting)
(55) (87) (6.5)
Manual override 4A 2B

1.2

(45)

(58)
42

52
- +

4A

2B
PE

1.2
6.5

5EA 1P 3EB
2 x M5 x 0.8
22.5 99.2 7.2
(PE port)
(103.2) (3.2)
Grommet (G) (H)
(26.5)
45.6 DC without light/surge voltage suppressor
G: Approx. 300 G: Approx. 300
H: Approx. 600 183.3 (41.6)
H: Approx. 600 185.7
(Lead wire length) (Lead wire length)
(78)
74

(49.3)
45.3
(32.5)
28.5

46.9
(42.9)
(15.5)
14

30 30
(31) (31)
50
1/4, 3/8, 1/2
(54)
92 [1(P), 5(EA), 3(EB) port]
The dimensions in ( ) are for 1/2 piping port size. (100)

02 02
L-type plug connector (L): VF5244-L1- 03  DIN terminal (D) (Y): VF5244- DY 1- 03 
04 04
Max. 10 197
Applicable cable O.D.
ø4.5 to ø7
Approx. 300 196
(Lead wire
length) Pg9
(118)
114

(109)
(55.3)

105
51.3

52
(48)
52.5
(48.5)

Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.

02 02
M-type plug connector (M): VF5244-M1- 03  Conduit terminal (T): VF5244-T1- 03 
04 04
Max. 10 201.8
Approx. 300
(Lead wire length)

Applicable cable O.D.


179.2
ø4.5 to ø7
130.5 38.5 (Indicator light)
(134.5) (34.5)
Pg9
(122.2 [112.2])
118.2 [108.2]

(112.2 [102.2])
108.2 [98.2]
(89)
85

54.9
43.6 (50.9)
(39.6) Unless otherwise indicated, dimensions are the same as Grommet (G).
Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: Without indicator light
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
24
VF-B.qxd 10.12.1 9:37 AM Page 30

Series VF3000/5000

Series VF5000/Base Mounted/Dimensions


3-position closed center/exhaust center/pressure center
3 02
H 1- 03 
Grommet (G) (H): VF5 4 44- G
04
5

1/4, 3/8, 1/2


27 36

(15.5)
[4(A), 2(B) port]
(31) (40)

14
20.5
(24.5)

(Indicator light)
51 2 x ø5.3 (2 x ø6.5) 82 5
(For mounting)

1.2
(55) (87) (6.5)
Manual override 4A 2B

(45)

(58)
42

52
- +

4A

2B
PE

1.2
6.5

5EA 1P 3EB
2 x M5 x 0.8
99.2 26.2
22.5
(PE port) Grommet (G) (H)
(26.5) (103.2) (22.2)
64.6
DC without light/surge voltage suppressor
G: Approx. 300
(60.6) G: Approx. 300
H: Approx. 600 202.3
H: Approx. 600 204.7
(Lead wire length)
(Lead wire
length)
(78)
74

(49.3)
45.3
(32.5)
28.5

65.9
(61.9)
(15.5)
14

30 30
(31) (31)
50
(54) 1/4, 3/8, 1/2
92
[1(P), 5(EA), 3(EB) port]
The dimensions in ( ) are for 1/2 piping port size. (100)

3 02 3 02
L-type plug connector (L): VF5 4 44-L1- 03  DIN terminal (D) (Y): VF5 4 44- DY 1- 03 
5 04 5 04
Max. 10 216
Applicable cable O.D.
Approx. 300 215 ø4.5 to ø7
(Lead wire
length)
Pg9
(55.3)

(118)
51.3

114

(109)
105

71
(67)
71.5
(67.5)
Unless otherwise indicated, dimensions are the same as Grommet (G). Unless otherwise indicated, dimensions are the same as Grommet (G).
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.

3 02 3 02
M-type plug connector (M): VF5 4 44-M1- 03  Conduit terminal (T): VF5 4 44-T1- 03 
5 04 5 04
(Lead wire length)

Applicable
Approx. 300

Max. 10 220.8
cable O.D.
198.2 ø4.5 to ø7
130.5 57.5 (Indicator light)
(134.5) (53.5)
Pg9
(122.2 [112.2])
118.2 [108.2]

(112.2 [102.2])
108.2 [98.2]
(89)
85

73.9
62.6
(69.9)
(58.6)
Unless otherwise indicated, dimensions are the same as Grommet (G).
Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: Without indicator light
The dimensions in ( ) are for 1/2 piping port size. The dimensions in ( ) are for 1/2 piping port size.
25
VF-B.qxd 10.12.1 9:37 AM Page 31

26
VF-B.qxd 10.12.1 9:37 AM Page 32

Pilot Operated 5 Port Solenoid Valve

Series VF1000/3000/5000
Body Ported Manifold Note) Only DIN and conduit terminal types
are available with AC mode.
How to Order Manifold Refer to the electrical entry for details.

Common exhaust Individual exhaust (VF1000 only)

VV5F 1 30 04 1 VV5F1 31 04 3
Series
Thread type Stations Thread type
1 VF1000
Stations Nil Rc 02 2 stations Nil Rc
3 VF3000
02 2 stations 00F G 00F G
5 VF5000
Manifold model 00N NPT 20 20 stations 00N NPT
Symbol P, R port size VF1000 VF3000 VF5000 20 20 stations 00T NPTF 00T NPTF
1/8  — — ∗ Up to 10 stations
30
1/4 —  — for VV5F5-20, and Manifold model
up to 15 stations
20 3/8 — —  for VV5F5-21. Symbol P, R port size EA, EB port size
21 1/2 — —  31 1/8 M5
∗ The A and B ports are made on the top.
How to Order Valve (With a gasket and two mounting screws)

VF 3 1 3 0 5 G 1 01
Series Thread type
1 VF1000 Type of actuation Nil Rc
Coil specification
3 VF3000 1 2-position single A, B port size F G
Nil Standard
5 VF5000 2 2-position double
Symbol Port size VF1000 VF3000 VF5000 N NPT
T With power saving circuit (DC only)
3 3-position closed center
M5 M5 x 0.8  — — T NPTF
Note) Be sure to select the
4 3-position exhaust center
power saving circuit type 01 1/8   — ∗ M5 is available
5 3-position pressure center when it is continuously 02 1/4 —   with Nil only.
∗ Only 1 and 2 are available with the VF1000. energized for long periods
of time. (Refer to back
03 3/8 — — 
pages 5 and 6 for details.)
Body option ∗ T type is available with DC mode Manual override
0: Pilot valve individual 3: Main/Pilot valve only. When T is selected, only Z Nil: Non-locking
exhaust common exhaust
type of light/surge voltage suppres- Light/surge voltage suppressor push type
sor is available. (Note that when
the electrical entry of DIN terminal Symbol Light/surge voltage suppressor DC AC
type without connector is selected, Nil Without light/surge voltage suppressor  
only DOS and YOS are available.)

Note)
S With surge voltage suppressor —
PE port EA/EB port PE port EA/EB port
Pressure specification Z With light/surge voltage suppressor  
Nil Standard (0.7 MPa)
VF1000 VF3000 VF5000 VF1000 VF3000 VF5000 R With surge voltage suppressor (Non-polar)  —
      K High-pressure type (1 MPa) U With light/surge voltage suppressor (Non-polar)  —
Rated voltage Note) There is no S option for AC mode, since a
Body model rectifier prevents surge voltage generation. D: Push-turn locking
Symbol VF1000 VF3000 VF5000 DC AC (50/60 Hz) ∗ In the DIN terminal type, since a light is installed slotted type
2 — —  5 24 VDC 1 100 VAC 4 220 VAC [230 VAC] in the connector, DOZ, DOU, YOZ, YOU are not
available.
3   —
Note)
6 12 VDC 2 200 VAC 7 240 VAC
Note) Manifold only 3 110 VAC [115 VAC] B 24 VAC
Electrical entry
DIN DIN (EN175301-803) Conduit
Grommet L-type plug connector M-type plug connector
terminal terminal terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible] E: Push-turn locking
lever type

G: Lead wire G: Lead wire L: With lead wire LN: M: With lead wire MN:
length 300 mm length 300 mm (length 300 mm) Without lead (length 300 mm) Without lead
H: Lead wire H: Lead wire wire wire D: With connector Y: With connector T: Conduit
length 600 mm length 600 mm terminal
DC
Without light/
surge voltage
suppressor LO: MO: DO: YO: Caution
Without connector Without connector Without connector Without connector When using the
CE DC surge voltage sup-
compliant AC Note 2) — — — pressor type, resid-
∗ LN and MN types are with 2 sockets. ∗ Refer to back page 3 when different length of lead wire for L/M-type plug connector is required. ual voltage will re-
∗ Refer to back page 4 for details on the DIN (EN175301-803) terminal. main. Refer to back
Note 1) When using with IP65, select the main/pilot valve common exhaust type. page 6 for details.
Note 2) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking compliant.
27
VF-B.qxd 10.12.1 9:37 AM Page 33

Pilot Operated 5 Port Solenoid Valve


Body Ported/Manifold Series VF1000/3000/5000

Manifold Specifications

Series VF1000 VF3000 VF5000


VV5F1-30 VV5F3-30 VV5F5-21
4(A), 2(B) port
4(A), 2(B) port 4(A), 2(B) port
1/4, 3/8
1/8 1/8, 1/4 1(P) port
1/2
1(P) port
1/4

VV5F5-20
VV5F1-31
4(A), 2(B) port
Manifold 4(A), 2(B) port
1(P) port 1/4, 3/8
base model 1/8 5(R), 3(R) port
1/8
5(R), 3(R) port 1/2
5/3(R) port
1/8 1/4
1(P) port
3/8

5(EA), 3(EB) port


M5 x 0.8 5(R), 3(R) port
1(P) port
1/8 3/8

EXH
Common EXH Individual EXH Common EXH Common EXH Common EXH
port type

Applicable VF130 VF330 VF520


valve model VF133 VF333 VF523
Applicable
2 to 20 stations 2 to 20 stations 2 to 10 stations 2 to 15 stations
stations

Manifold base
Weight: W [g] W = 29n + 21 W = 51n + 35 W = 63n + 64 W = 97n + 80 W = 139n + 550
Stations: n

Note) Supply pressure to 1(P) ports and exhaust pressure from R ports on both sides for 10 stations or more (5 stations or more for the VF5000).

How to Order Manifold Assembly

Example (VV5F3-30)
Closed center (24 VDC) Double solenoid (24 VDC)
VF3330-5GZ1-02 (1 set) VF3230-5GZ1-02 (1 set)

Single solenoid (24 VDC)


VF3130-5GZ1-02 (3 sets)

Manifold base (5 stations)


Us
ide VV5F3-30-051
Sta
tion
s

3
2
1 Ds
ide

VV5F3-30-051 ···························· 1 set (Type 30, 5-station manifold base part no.)
∗ VF3130-5GZ1-02 ······················· 3 sets (Single solenoid part no.)
∗ VF3230-5GZ1-02 ······················· 1 set (Double solenoid part no.)
∗ VF3330-5GZ1-02 ······················· 1 set (Closed center part no.)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

• The valve arrangement is numbered as the 1st station from D side.


• Indicate the valves to be attached below the manifold base part number, in order starting from station 1
as shown in the drawing. If the arrangement becomes complicated, then indicate on the manifold
specification sheet.

28
VF-B.qxd 10.12.1 9:37 AM Page 34

Series VF1000/3000/5000

Manifold Options
 For body ported  Mounting screw, gasket part no.
Blanking plate assembly

Valve mounting screw

Gasket

Series Blanking plate assembly part no. Series Valve mounting screw (1 pc.) Gasket
VF1000 DXT144-13-3A VF1000 Round head combination screw DXT144-12-2
VF3000 DXT031-38-5A DXT031-44-1
VF3000 (With M4 x 39.5 SW) DXT155-25-7
VF5000 VF5000-70-1A
Hexagon socket head cap screw
VF5000 AXT620-32-1 DXT156-9-6
(With M4 x 48 SW)
 Individual EXH spacer assembly

Caution
Tightening Torque of Mounting Screw
M4: 1.4 N·m

Warning
When mounting a valve or spacer on the manifold base or sub-plate,
etc., the mounting orientation is already decided. If mounted in a
wrong direction, the equipment to be connected may result in mal-
function. Refer to external dimensions in mounting.

EXH port

EXH port

VF 3 000 75 1 A
Series Thread type
Symbol Series Port size Nil Rc
3 VF3000 1/8 F G
5 VF5000 1/4 N NPT
T NPTF

29
VF-B.qxd 10.12.1 9:37 AM Page 35

Pilot Operated 5 Port Solenoid Valve


Body Ported/Manifold Series VF1000/3000/5000

Series VF1000/Dimensions
Type 30/VV5F1-30-1-: Common exhaust
Grommet (G) (H)
1/8 Grommet (G) (H)
[4(A), 2(B) port] DC without light/
2 x ø5.5 surge voltage suppressor
L1
(For mounting)
L2 5 M5 x 0.8
[4(A), 2(B) port]
M5
12 10
23.8
17.5

17.8
10

6
124.4

126.8
4A
R

R
4A

4A

4A

4A

4A
R

21
35
2B
2B

2B

2B

2B

2B

P
P

11.5
62.2

63.4
1/8
23.8

[1(P), 5/3(R) port]


Manual
override PE port
(Pitch) 1.7
(Lead wire length)

(Lead wire length)


P = 27.5 23.5 36.3
G: Approx. 300

G: Approx. 300
H: Approx. 600

H: Approx. 600
(Station n) (Station 1)

(Indicator light) L-type plug connector (L)

- + - + - + - + - +
65
42
20

137.1
68.5

L: Dimensions n: Stations
(Lead wire length)

n 2 3 4 5 6 7 8 9 10 11 12 13 14 42.3
L
Approx. 300

L1 74.5 102 129.5 157 184.5 212 239.5 267 294.5 322 349.5 377 404.5
L2 64.5 92 119.5 147 174.5 202 229.5 257 284.5 312 339.5 367 394.5

n 15 16 17 18 19 20
L
L1 432 459.5 487 514.5 542 569.5
L2 422 449.5 477 504.5 532 559.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)

(Indicator light)
120.3
110.1

138.1

142.9
60.1
55

71.5
69

Approx. 300 76 Pg9


Pg9
(Lead wire length)
Max. 10
Max. 10

96 99.2 [89.2]
105 109.2 [99.2]
Applicable cable O.D.
Applicable cable O.D.
ø4.5 to ø7
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
30
VF-B.qxd 10.12.1 9:37 AM Page 36

Series VF1000/3000/5000

Series VF1000/Dimensions
Type 31/VV5F1-31-3-: Individual exhaust
Grommet (G) (H) Grommet (G) (H)
DC without light/
surge voltage suppressor

(Lead wire length)


(Lead wire length)

G: Approx. 300
H: Approx. 600
G: Approx. 300
H: Approx. 600

L1
M5 M5 x 0.8
5 L2 41.3
Manual [4(A), 2(B) port]
override
7.5
1/8
23.8

63.4
62.2

[1(P) port]
11.5

6
124.4

126.8
2B

2B

2B

2B

2B

2B
P

P
P

34
4A

4A

4A

4A

4A

4A

9.3
17
17.8

10
23.8

ø8.2
2 x ø5.5 (Not used.)
1.7 (For mounting)
(Pitch) PE port
23.5 P = 27.5 1/8
[4(A), 2(B) port]

(Station 1) (Station n)

(Indicator light)
L-type plug connector (L)

(Lead wire length)


- + - +

Approx. 300
70
47
25

EA EB EA EB 47.3
M5 x 0.8
[5(EA), 3(EB) port]
11 (Pitch)
18 P = 27.5
68.5
137.1

L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 74.5 102 129.5 157 184.5 212 239.5 267 294.5 322 349.5 377 404.5
L2 64.5 92 119.5 147 174.5 202 229.5 257 284.5 312 339.5 367 394.5

n 15 16 17 18 19 20
L
L1 432 459.5 487 514.5 542 569.5
L2 422 449.5 477 504.5 532 559.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
Applicable cable Applicable cable
O.D. O.D.
ø4.5 to ø7 ø4.5 to ø7
110 114.2 [104.2]
Approx. 300 81
Max. 10
Max. 10

(Lead wire length) 101 104.2 [94.2]


Pg9 Pg9
60.1
55
120.3
110.1

71.5
69

(Indicator light)
138.1

142.9

[ ]: Without indicator light


Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
31
VF-B.qxd 10.12.1 9:37 AM Page 37

Pilot Operated 5 Port Solenoid Valve


Body Ported/Manifold Series VF1000/3000/5000

Series VF3000/Dimensions
Type 30/VV5F3-30-1-: Common exhaust
Grommet (G) (H)
Grommet (G) (H)
DC without light/
L1 surge voltage suppressor

)
.8) ce rts
L2 6

(23 stan n po
1/8, 1/4
17.5

e
[4(A), 2(B) port]

(D twe
11.5

be
i
1
52.5
36.5

32.5
R
R
165.9

168.3
2B

2B

2B

2B

2B

149.9

152.3
46
65
P
P
36.5

24
23

4A

4A

4A

4A

4A

R
R

76.2
75

4 x ø5.5 1/4
(For mounting) [1(P), 5(R), 3(R) port]

1.7 PE port

G: Approx. 300
H: Approx. 600
(Lead wire length)

(Lead wire length)


(Pitch) 43.8
G: Approx. 300
H: Approx. 600

Manual
P = 27.5 28
override

(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)

- + - + - + - + - +
72.5
49.5
27

178.6
162.6
81.3

L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
(Lead wire length)

49.8
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5
Approx. 300

L2 71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5

n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6

161.8

179.6

184.4
135.6

145.8

163.6

168.4

(Indicator light)
67.8

72.9

81.8

84.2

Approx. 300 83.5 Pg9 Pg9


(Lead wire length)
Max. 10
Max. 10

103.5 Applicable 106.7 [96.7]


112.5 cable O.D.
ø4.5 to ø7 116.7 [106.7]
Applicable
cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
32
VF-B.qxd 10.12.1 9:37 AM Page 38

Series VF1000/3000/5000

Series VF3000/Dimensions
Type 30/VV5F3-30-1-: When the individual EXH spacer (VF3000-75-1A) is mounted.
Grommet (G) (H)
Grommet (G) (H)
DC without light/
L1 1/8, 1/4 surge voltage suppressor

)
.8) ce rts
L2 6 [4(A), 2(B) port]

(23 stan n po
e
(D twe
17.5

be
i
1 11.5
52.5
36.5

32.5
R
R
165.9

168.3
2B

2B

2B

2B

2B

149.9

152.3
46
65
P
P
36.5
23

24
4A

4A

4A

4A

4A

R
R

76.2
75

4 x ø5.5 1/4
(For mounting) [1(P), 5(R), 3(R) port]

1.7 PE port
(Lead wire length)

G: Approx. 300
H: Approx. 600
Manual

(Lead wire length)


(Pitch) 59.8
G: Approx. 300
H: Approx. 600

override P = 27.5 28

(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)

Individual EXH spacer - + - + - + - + - +

(VF3000-75-1A)
88.5
65.5

EXH. EXH. EXH. EXH. EXH.


35.5

178.6
27

162.6

1/8 5
(EXH port)
81.3

L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
(Lead wire length)

L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5 65.8
Approx. 300

L2 71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5

n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6

161.8

179.6

184.4
135.6

145.8

163.6

168.4

(Indicator light)
67.8

72.9

81.8

84.2

Approx. 300 99.5


Pg9 Pg9
(Lead wire length)
Max. 10
Max. 10

119.5 Applicable 122.7 [112.7]


cable O.D.
128.5 132.7 [122.7]
ø4.5 to ø7

Applicable cable O.D.


ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
33
VF-B.qxd 10.12.1 9:37 AM Page 39

Pilot Operated 5 Port Solenoid Valve


Body Ported/Manifold Series VF1000/3000/5000

Series VF5000/Dimensions
Type 20/VV5F5-20-1-: Common exhaust
Grommet (G)
Grommet (G) (H)
L1 DC without light/
L2 6.5 surge voltage suppressor
1/4, 3/8
[4(A), 2(B) port]
17.5
3
12.5

rts)
72.2
53.2

50.5

een po
30
28

R
202.3

204.7
183.3

185.7
2B

2B

2B

2B

2B

60
83
P

ce betw
4A

4A

4A

4A

4A
53.2

91.7

92.9

n
3/8

ta
(30.4)
is
[1(P), 5(R), 3(R) port]

(D
PE port
4 x ø7

G: Approx. 300
H: Approx. 600
1.2
(Pitch) (For mounting) 47.3

(Lead wire
P = 33 30 Manual override

length)
(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)

- + - + - + - + - +
76
53
29.5

215
196
98
Approx. 300
(Lead wire

53.3
L: Dimensions n: Stations
length)

n 2 3 4 5 6 7 8 9 10
L
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

198.2

220.8
216
179.2

201.8
197

(Indicator light)
84.5

89.6

100.9
98.5

Approx. 300 87 Pg9 Pg9


(Lead wire length)
Max. 10

107 Applicable
Max. 10

110.2 [100.2]
116 cable O.D.
ø4.5 to ø7 120.2 [110.2]
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
34
VF-B.qxd 10.12.1 9:37 AM Page 40

Series VF1000/3000/5000

Series VF5000/Dimensions
Type 20/VV5F5-20-1-: When the individual EXH spacer (VF5000-75-1A) is mounted.
Grommet (G)
Grommet (G) (H)
L1 DC without light/
L2 6.5 surge voltage suppressor
1/4, 3/8
[4(A), 2(B) port]
17.5
3
12.5

rts)
72.2
53.2

50.5

een po
30
28

R
202.3

204.7
183.3

185.7
2B

2B

2B

2B

2B

60
83
P

ce betw
4A

4A

4A

4A

4A
53.2

91.7

92.9

(Distan
(30.4)
G: Approx. 300
H: Approx. 600
1.2 4 x ø7
PE port
(For mounting) 73.8

(Lead wire
(Pitch)
P = 33 30 Manual override 3/8

length)
[1(P), 5(R), 3(R) port]

(Station n) (Station 1)
L-type plug connector (L)
(Indicator light)

Individual EXH
spacer - + - + - + - + - +

(VF5000-75-1A)
102.5

R R R R R
79.5
43.5

215
29.5

196

1/4
EXH port
98
Approx. 300
(Lead wire

79.8
L: Dimensions n: Stations
length)

n 2 3 4 5 6 7 8 9 10
L
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

198.2

220.8
216
179.2

201.8
197

(Indicator light)
84.5

89.6

100.9
98.5

Approx. 300 113.5 Pg9 Pg9


Applicable
Max. 10

(Lead wire length)


Max. 10

133.5 136.7 [126.7]


cable O.D.
142.5 146.7 [136.7]
ø4.5 to ø7
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
35
VF-B.qxd 10.12.1 9:37 AM Page 41

Pilot Operated 5 Port Solenoid Valve


Body Ported/Manifold Series VF1000/3000/5000

Series VF5000/Dimensions
Type 21/VV5F5-21-1-: Common exhaust
Grommet (G)
Grommet (G) (H)
L1 DC without light/
L2 17.5 surge voltage suppressor
20
15
3

)
72.2

en ports
53.2
202.3

204.7
183.3

185.7
2B

2B

2B

2B

2B

110
125
28

68

e betwe
P

P
4A

4A

4A

4A

4A
53.2
91.7

92.9

(Distanc
R

(34.4)
G: Approx. 300
H: Approx. 600
4 x ø9
1/4, 3/8 PE port
1.2 (For mounting) 49.8
[4(A), 2(B) port]

(Lead wire
Manual override 1/2

length)
(Pitch)
[1(P), 5(R), 3(R) port]
P = 33 30

(Station n) (Station 1) L-type plug connector (L)

(Indicator light)

- + - + - + - + - +

R
78.5
55.5

215
35

196

P
2.5

98

R
Approx. 300
(Lead wire

55.8
L: Dimensions n: Stations
length)

n 2 3 4 5 6 7 8 9 10 11 12 13 14 15
L
L1 163 196 229 262 295 328 361 394 427 460 493 526 559 592
L2 128 161 194 227 260 293 326 359 392 425 458 491 524 557 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

R
198.2

220.8
216
179.2

201.8
197
P

(Indicator light)
84.5

89.6

100.9
98.5
R

Approx. 300 89.5 Pg9 Pg9


Max. 10

(Lead wire length)


Max. 10

109.5 Applicable 112.7 [102.7]


cable O.D.
118.5 122.7 [112.7]
ø4.5 to ø7
Applicable cable O.D.
ø4.5 to ø7
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the [ ]: Without indicator light
same as Grommet (G). same as Grommet (G). Unless otherwise indicated, dimensions are the
same as Grommet (G).
36
VF-B.qxd 10.12.1 9:37 AM Page 42

Series VF1000/3000/5000

Series VF5000/Dimensions
Type 21/VV5F5-21-1-: When the individual EXH spacer (VF5000-75-1A) is mounted.
Grommet (G)
Grommet (G) (H)
L1 DC without light/
L2 17.5 surge voltage suppressor

20
15
3

)
R

R
72.2

en ports
53.2
202.3

204.7
183.3

185.7
2B

2B

2B

2B

2B

110
125
28

68

e betwe
P

P
4A

4A

4A

4A

4A
53.2
91.7

92.9

(Distanc
R

(34.4)
G: Approx. 300
H: Approx. 600
4 x ø9
1/4, 3/8 PE port
(For mounting) 76.3

(Lead wire
[4(A), 2(B) port] 1.2
Manual override 1/2

length)
(Pitch) [1(P), 5(R), 3(R) port]
P = 33 30

(Station n) (Station 1) L-type plug connector (L)

(Indicator light)
Individual EXH
spacer
- + - + - + - + - +
(VF5000-75-1A)

R
105

R R R R R
215
82

196

P
46
35
2.5

1/4
98

R
EXH port
Approx. 300
(Lead wire

82.3
L: Dimensions n: Stations
length)

n 2 3 4 5 6 7 8 9 10 11 12 13 14 15
L
L1 163 196 229 262 295 328 361 394 427 460 493 526 559 592
L2 128 161 194 227 260 293 326 359 392 425 458 491 524 557 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

R
198.2

220.8
216
179.2

201.8
197
P

P
84.5

(Indicator light)
89.6

100.9
98.5
R

Approx. 300 116 Pg9 Pg9


(Lead wire length)
Max. 10

Max. 10

136 Applicable 139.2 [129.2]


cable O.D.
145 149.2 [139.2]
ø4.5 to ø7
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
37
VF-B.qxd 10.12.1 9:37 AM Page 43

38
VF-B.qxd 10.12.1 9:37 AM Page 44

Pilot Operated 5 Port Solenoid Valve

Series VF3000/5000
Base Mounted Manifold Note) Only DIN and conduit terminal types
are available with AC mode.
How to Order Manifold Refer to the electrical entry for details.

Common exhaust VV5F 3 40 05 2 02 F


Series Stations Thread type
Symbol Series P, R port size A, B port size 02 2 stations Nil Rc
3 VF3000 1/4 1/4 F G
5 VF5000 3/8 1/4 20 20 stations N NPT
∗ The A and B ports are made on the bottom. ∗ Up to 10 stations for VV5F5. T NPTF

How to Order Valve (With a gasket and two mounting screws)

VF 3 1 4 0 5 G 1
Series Manual override
3 VF3000 Type of actuation Nil: Non-locking D: Push-turn locking E: Push-turn locking
5 VF5000 1 2-position single push type slotted type lever type
∗ Not available 2 2-position double
with the VF1000. 3 3-position closed center
4 3-position exhaust center
5 3-position pressure center

Body model
Body option
0: Pilot valve individual exhaust Light/surge voltage suppressor
Pressure specification Symbol Light/surge voltage suppressor DC AC
Nil Standard (0.7 MPa) Nil Without light/surge voltage suppressor  
K High-pressure type (1 MPa) S With surge voltage suppressor  —
Note)

PE port EA/EB port


Z With light/surge voltage suppressor  
VF3000 VF5000
R With surge voltage suppressor (Non-polar)  —
 —
U With light/surge voltage suppressor (Non-polar)  —
3: Main/Pilot valve common Rated voltage
Note) There is no S option for AC mode, since a rectifier prevents
exhaust
DC AC (50/60 Hz) surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the connector,
5 24 VDC 1 100 VAC DOZ, DOU, YOZ, YOU are not available.
6 12 VDC 2 200 VAC
PE port EA/EB port 3 110 VAC [115 VAC] Caution
VF3000 VF5000 4 220 VAC [230 VAC]
When using the surge voltage suppressor type,
 — 7 240 VAC
residual voltage will remain. Refer to back page 6
4: Pilot valve base exhaust B 24 VAC
for details.
Electrical entry
DIN DIN (EN175301-803) Conduit
PE port Grommet L-type plug connector M-type plug connector
terminal terminal terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
VF3000 VF5000
— 
Coil specification
Nil Standard
T With power saving circuit (DC only) G: Lead wire G: Lead wire L: With lead wire LN: M: With lead wire MN:
Note) Be sure to select the power saving length 300 mm length 300 mm (length 300 mm) Without lead (length 300 mm) Without lead
circuit type when it is continuously H: Lead wire H: Lead wire wire wire D: With connector Y: With connector T: Conduit
energized for long periods of time. length 600 mm length 600 mm terminal
(Refer to back pages 5 and 6 for DC
details.) Without light/
∗ T type is available with DC mode only. surge voltage
When T is selected, only Z type of suppressor
light/surge voltage suppressor is avail-
LO: MO: DO: YO:
able. (Note that when the electrical en-
Without connector Without connector Without connector Without connector
try of DIN terminal type without
connector is selected, only CE DC
DOS and YOS are available.) compliant AC Note 2) — — —
∗ LN and MN types are with 2 sockets. ∗ Refer to back page 3 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to back page 4 for details on the DIN (EN175301-803) terminal.
Note 1) When using with IP65, select the main/pilot valve common exhaust or pilot valve base exhaust type.
Note 2) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking compliant.
39
VF-B.qxd 10.12.1 9:37 AM Page 45

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Manifold Series VF3000/5000

Manifold Specifications

EXH Applicable valve Applicable Manifold base


Series Manifold base model
port type model stations Weight: W [g] Stations: n

VV5F3-40

5(R), 3(R) port


1/4

Common VF340 2 to 20
VF3000 EXH VF343 stations
W = 110n + 116

1(P) port
1/4

4(A), 2(B) port


1/4

VV5F5-40 PE port
M5 x 0.8

5(R), 3(R) port


3/8

Common 2 to 10
VF5000 EXH
VF544 stations
W = 161n + 128

1(P) port
3/8
4(A), 2(B) port
1/4

Note) Supply pressure to 1(P) ports and exhaust pressure from R ports on both sides for 10 stations or more (5 stations or more for the VF5000).

How to Order Manifold Assembly

Example (VV5F3-40)

Closed center (24 VDC) Double solenoid (24 VDC)


VF3340-5GZ1 (1 set) VF3240-5GZ1 (1 set)

Single solenoid (24 VDC)


VF3140-5GZ1 (3 sets)

Us Manifold base (5 stations)


ide VV5F3-40-052-02
Sta
tion
s

3
2
1 Ds
ide

VV5F3-40-052-02 ······················· 1 set (Type 40, 5-station manifold base part no.)
∗ VF3140-5GZ1 ······················· 3 sets (Single solenoid part no.)
∗ VF3240-5GZ1 ······················· 1 set (Double solenoid part no.)
∗ VF3340-5GZ1 ······················· 1 set (Closed center part no.)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

• The valve arrangement is numbered as the 1st station from D side.


• Indicate the valves to be attached below the manifold base part number, in order starting from station 1
as shown in the drawing. If the arrangement becomes complicated, then indicate on the manifold
specification sheet.

40
VF-B.qxd 10.12.1 9:37 AM Page 46

Series VF3000/5000

Manifold Options
 For base mounted  Mounting screw, gasket part no.
Blanking plate assembly

Valve mounting screw

Gasket

Series Blanking plate assembly part no. Series Valve mounting screw (1 pc.) Gasket
VF3000 DXT031-38-5A Round head combination screw
VF5000 VF5000-70-2A VF3000 DXT031-44-1 DXT031-30-11
(With M4 x 39.5 SW)
Hexagon socket head cap screw
VF5000 AXT620-32-1 DXT156-9-8
(With M4 x 48 SW)
 Individual EXH spacer assembly

Caution
Tightening Torque of Mounting Screw
M4: 1.4 N·m

Warning
When mounting a valve or spacer on the manifold base or sub-plate,
etc., the mounting orientation is already decided. If mounted in a
wrong direction, the equipment to be connected may result in mal-
function. Refer to external dimensions in mounting.
EXH port

EXH port

VF 3 000 75 2 A
Series Thread type
Symbol Series Port size Nil Rc
3 VF3000 1/8 F G
5 VF5000 1/4 N NPT
T NPTF
41
VF-B.qxd 10.12.1 9:37 AM Page 47

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Manifold Series VF3000/5000

Series VF3000/Dimensions
Type 40/VV5F3-40-2-02: Common exhaust
Grommet (G) (H) Grommet (G) (H)
L1 DC without light/
L2 6 surge voltage suppressor
19

ts)
13

por
0.5

ween
52.5

et
36.5

eb
33
165.9

168.3
R
R

23 23
149.9

152.3

tanc
66
P
P
36.5

(Dis
8
24
R
R

.
(23
76.2
75

1/4
[1(P), 5(R), 3(R) port]

1.7 Manual override


(Pitch)
(Lead wire length)

4 x ø5.5

(Lead wire length)


46.8
P = 27.5 28
G: Approx. 300

G: Approx. 300
H: Approx. 600

H: Approx. 600
(For mounting)

(Station n) (Station 1)

(Indicator light)

- + - + - + - + - +
75.5
52.5
30

ø2.3
(PE port)
1/4 L-type plug connector (L)
[4(A), 2(B) port]
(29. nce be
(Dis
7)
ta

A A
28

B B
178.6
twe

162.6

10
en

(Pitch)
port

P = 27.5 23
81.3
s)

L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5
Approx. 300

L2 52.8
(Lead wire

71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5
length)

n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6

161.8

179.6

184.4
135.6

145.8

163.6

168.4

(Indicator light)
67.8

72.9

81.8

84.2

Approx. 300 86.5 Pg9 Pg9


(Lead wire length) Applicable
Max. 10

106.5
Max. 10

cable O.D. 109.7 [99.7]


115.5
ø4.5 to ø7 119.7 [109.7]
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
42
VF-B.qxd 10.12.1 9:37 AM Page 48

Series VF3000/5000

Series VF3000/Dimensions
Type 40/VV5F3-40-2-02: When the individual EXH spacer (VF3000-75-2A) is mounted.
Grommet (G) (H) Grommet (G) (H)
L1 DC without light/
L2 6 surge voltage suppressor
19

)
orts
13

en p
0.5

twe
52.5

e be
36.5 36.5

33
165.9

168.3
R
R

23 23
149.9

152.3

tanc
66
P
P

(Dis
.8
24
R

(23
R

76.2
75

1/4
[1(P), 5(R), 3(R) port]

1.7 Manual override


(Pitch)
(Lead wire length)

(Lead wire length)


4 x ø5.5 62.8
P = 27.5 28
G: Approx. 300

G: Approx. 300
H: Approx. 600

H: Approx. 600
(For mounting)

(Station n) (Station 1)
(Indicator light)

- + - + - + - + - +
Individual EXH
spacer
91.5
68.5

EXH. EXH. EXH. EXH. EXH.

(VF3000-75-2A)
38.5
30

1/8 5
(EXH port) ø2.3
(PE port) L-type plug connector (L)
(29. nce be
(Dis

1/4
7)
ta

[4(A), 2(B) port]


twe

A A
28

B B
en

178.6
port

162.6
s)

10
(Pitch)
P = 27.5 23
81.3

L: Dimensions n: Stations
n 2 3 4 5 6 7 8 9 10 11 12 13 14
L
L1 83.5 111 138.5 166 193.5 221 248.5 276 303.5 331 358.5 386 413.5
Approx. 300
(Lead wire

L2 71.5 99 126.5 154 181.5 209 236.5 264 291.5 319 346.5 374 401.5 68.8
length)

n 15 16 17 18 19 20
L
L1 441 468.5 496 523.5 551 578.5
L2 429 456.5 484 511.5 539 566.5 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
151.6

161.8

179.6

184.4
135.6

145.8

163.6

168.4

(Indicator light)
67.8

72.9

81.8

84.2

Approx. 300 102.5 Pg9 Pg9


(Lead wire length) Applicable
Max. 10

122.5
Max. 10

125.7 [115.7]
131.5 cable O.D.
ø4.5 to ø7 135.7 [125.7]
Applicable cable O.D.
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
43
VF-B.qxd 10.12.1 9:37 AM Page 49

Pilot Operated 5 Port Solenoid Valve


Base Mounted/Manifold Series VF3000/5000

Series VF5000/Dimensions
Type 40/VV5F5-40-2-02: Common exhaust
Grommet (G) Grommet (G) (H)
L1 DC without light/
L2 6.5
surge voltage suppressor

28
20.5

)
rts
po
13

en
e
etw
) ce b
72.2
53.2

50.5

(1 ista n
PE

PE
R

R
202.3

204.7

(D
rts
7
183.3

185.7

(27.3 between po
55
71
79
P
P

1.3
53.2

27.5
R

PE

PE
91.7

92.9

nce
)
3/8

(Dista
[1(P), 5(R), 3(R) port]
M5 x 0.8
4 x ø7
1.2 (PE port)
(Pitch) (For mounting)

(Lead wire length)


49.3

G: Approx. 300
P = 33 30

H: Approx. 600
Manual override

(Station n) (Station 1)

(Indicator light)

- + - + - + - + - +
L-type plug connector (L)
78
55
32.5

PE
215
196

1/4
[4(A), 2(B) port]

PE
98

A A
24

B B
Approx. 300
(Lead wire

55.8
L: Dimensions n: Stations
length)

(Pitch) n 2 3 4 5 6 7 8 9 10
L
P = 33 30
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

PE

PE

PE
198.2

220.8
216
179.2

201.8
197
PE

PE

PE

(Indicator light)
84.5

89.6

100.9
98.5

Approx. 300 89 Pg9 Pg9


(Lead wire length)
Max. 10

Applicable
Max. 10

109 112.2 [102.2]


118 cable O.D.
122.2 [112.2]
Applicable cable O.D. ø4.5 to ø7
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
44
VF-B.qxd 10.12.1 9:37 AM Page 50

Series VF3000/5000

Series VF5000/Dimensions
Type 40/VV5F5-40-2-02: When the individual EXH spacer (VF5000-75-2A) is mounted.
Grommet (G) Grommet (G) (H)
L1 DC without light/
surge voltage suppressor
L2 6.5 ts)
por
eenw
28 bet
ce n
20.5 ista (D
7)
13 (1
72.2
53.2

50.5

rts)
PE
PE
R

204.7
202.3

(27.3 between po
185.7
183.3

55
71
79
P
P

1.3
53.2

27.5

PE
R

PE

nce
91.7

92.9

)
ta
3/8

(Dis
[1(P), 5(R), 3(R) port]

M5 x 0.8
1.2 4 x ø7
(Pitch) (PE port)
(For mounting)

(Lead wire length)


P = 33 30 74.8

G: Approx. 300
H: Approx. 600
Manual override

(Station n) (Station 1)
(Indicator light)

Individual EXH
- + - + - + - + - +
spacer
(VF5000-75-2A) L-type plug connector (L)
103.5

R R R R R
80.5
45.5
32.5

1/4 4
(EXH port)

PE
215
196

1/4
[4(A), 2(B) port]

PE
98

A A
24

B B
Approx. 300
(Lead wire

80.8
L: Dimensions n: Stations
length)

(Pitch) n
P = 33 30 L 2 3 4 5 6 7 8 9 10
L1 93 126 159 192 225 258 291 324 357
L2 80 113 146 179 212 245 278 311 344 Unless otherwise indicated, dimensions are the
same as Grommet (G).

M-type plug connector (M) DIN terminal (D) (Y) Conduit terminal (T)
103.5
84.5

PE

PE

PE
198.2

220.8
216
179.2

201.8
197
PE

PE

PE

(Indicator light)
84.5

89.6

100.9
98.5

Approx. 300 114.5 Pg9 Pg9


Max. 10

(Lead wire length) 134.5 Applicable


Max. 10

137.7 [127.7]
143.5 cable O.D.
147.7 [137.7]
Applicable cable O.D. ø4.5 to ø7
ø4.5 to ø7 [ ]: Without indicator light
Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the Unless otherwise indicated, dimensions are the
same as Grommet (G). same as Grommet (G). same as Grommet (G).
45
VF-B.qxd 10.12.1 9:37 AM Page 51
VF-B.qxd 10.12.1 9:37 AM Page 52

These safety instructions are intended to prevent hazardous situations and/or


Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or
moderate injury.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots - Safety.
Warning: risk which, if not avoided, could result in death or
serious injury.
etc.

Danger indicates a hazard with a high level of risk


Danger : which, if not avoided, will result in death or serious
injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating If considering using the product in other industries, consult SMC
conditions, its compatibility with specific equipment must be decided by beforehand and exchange specifications or a contract if necessary.
the person who designs the equipment or decides its specifications
If anything is unclear, contact your nearest sales branch.
based on necessary analysis and test results. The expected performance
and safety assurance of the equipment will be the responsibility of the
person who has determined its compatibility with the product. This person
should also continuously review all specifications of the product referring Limited warranty and Disclaimer/
to its latest catalog information, with a view to giving due consideration to
any possibility of equipment failure when configuring the equipment. Compliance Requirements
2. Only personnel with appropriate training should operate The product used is subject to the following “Limited warranty and
machinery and equipment. Disclaimer” and “Compliance Requirements”.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment
Read and accept them before using the product.
including our products must be performed by an operator who is
appropriately trained and experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and 1. The warranty period of the product is 1 year in service or 1.5
machinery/equipment until safety is confirmed.
years after the product is delivered.∗2)
1. The inspection and maintenance of machinery/equipment should only
be performed after measures to prevent falling or runaway of the Also, the product may have specified durability, running distance or
driven objects have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures
2. For any failure or damage reported within the warranty period which is
as mentioned above are implemented and the power from any
appropriate source is cut, and read and understand the specific clearly our responsibility, a replacement product or necessary parts will
product precautions of all relevant products carefully. be provided.
3. Before machinery/equipment is restarted, take measures to prevent This limited warranty applies only to our product independently, and not
unexpected operation and malfunction. to any other damage incurred due to the failure of the product.
4. Contact SMC beforehand and take special consideration of
3. Prior to using SMC products, please read and understand the warranty
safety measures if the product is to be used in any of the
following conditions. terms and disclaimers noted in the specified catalog for the particular
1. Conditions and environments outside of the given specifications, or use products.
outdoors or in a place exposed to direct sunlight. ∗2) Vacuum pads are excluded from this 1 year warranty.
2. Installation on equipment in conjunction with atomic energy, railways, A vacuum pad is a consumable part, so it is warranted for a year after it is
air navigation, space, shipping, vehicles, military, medical treatment, delivered.
Also, even within the warranty period, the wear of a product due to the use of
combustion and recreation, or equipment in contact with food and
the vacuum pad or failure due to the deterioration of rubber material are not
beverages, emergency stop circuits, clutch and brake circuits in press covered by the limited warranty.
applications, safety equipment or other applications unsuitable for the
standard specifications described in the product catalog.
3. An application which could have negative effects on people, property,
or animals requiring special safety analysis.
Compliance Requirements
4. Use in an interlock circuit, which requires the provision of double 1. The use of SMC products with production equipment for the manufac-
interlock for possible failure by using a mechanical protective function, ture of weapons of mass destruction (WMD) or any other weapon is
and periodical checks to confirm proper operation.
strictly prohibited.

2. The exports of SMC products or technology from one country to


another are governed by the relevant security laws and regulations of
the countries involved in the transaction. Prior to the shipment of a
SMC product to another country, assure that all local rules governing
that export are known and followed.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

Back page 1
VF-B.qxd 10.12.1 9:37 AM Page 53

Series VF
Specific Product Precautions 1
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Manual Override How to Use L/M-Type Plug Connector

Warning Caution
Without an electric signal for the solenoid valve the 1. Attaching and detaching connectors
manual override is used for switching the main valve. • To attach a connector, hold the lever and connector unit
Connected actuator is started by manual operation. between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
Use the manual override after confirming that there is groove and locks.
no danger. • To detach a connector, remove the pawl from the groove by
 Non-locking push type
pushing the lever downward with your thumb, and pull the
connector straight out.
Cover
Push down on the manual
override with a small
Groove
screwdriver until it stops. Pin Lever
Release the screwdriver DC polarity indication
and the manual override Cover

will return. Groove


Pin Connector

 Push-turn locking slotted type Socket

Lead wire
Lever
Locked condition

2. Crimping lead wires and sockets


Not necessary if ordering the lead wire pre-connected model.
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
PUSH

LOCK

ends of the core wires evenly into the sockets, and then crimp
with a crimping tool. When this is done, take care that the
coverings of the lead wires do not enter the core wire crimping
area. (Please contact SMC for details on the crimping tool.)
Core wire Crimping area
crimping area
Socket
Core wire
(Part no.: DXT170-71-1)
Push down on the manual override with a small flat head Lead wire
screwdriver until it stops. Turn it clockwise by 90° to lock it. Turn
it counterclockwise to release it. Insulation

Hook 0.2 to 0.33 mm2


 Push-turn locking lever type Max. cover diameter: ø1.9 mm

Locked condition 3. Attaching and detaching sockets with lead wire


• Attaching
Insert the sockets into the square holes of the connector (+, –
indication), and continue to push the sockets all the way in
until they lock by hooking into the seats in the connector.
PUSH

LOCK

(When they are pushed in, their hooks open and they are
locked automatically.) Then, confirm that they are locked by
pulling lightly on the lead wires.
• Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket’s hook with a stick having a thin tip
After pushing down, turn in the direction of the arrow. If it is not turned, (approx. 1 mm). If the socket will be used again, first spread
it can be operated the same way as the non-locking push type. the hook outward.

Caution Socket Connector


Lead wire
When locking the manual override with the push-turn locking type
(D or E type), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and other trouble such as air leakage, etc. Hook Insert a socket into square hole Not in use
Do not apply excessive torque when turning the locking type
manual override. (0.1 N·m)
Back page 2
356-VF-CT.qxd 11.1.12 5:02 PM Page 3

Series VF
Specific Product Precautions 2
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Plug Connector Lead Wire Length How to Use DIN Terminal


The DIN terminal type with an IP65 (enclosure) is protected
Caution against dust and water, however, it must not be used in water.
Plug connector lead wires have a standard length of
300 mm, however, the following lengths are also Caution
available.
Connection
1) Loosen the set screw and pull the connector out of the sole-
How to Order Connector Assembly noid valve terminal block.
2) After removing the set screw, insert a flat head screwdriver,
DC : V200-30-4A- etc. into the notch on the bottom of the terminal block and pry
it open, separating the terminal block and the housing.
3) Loosen the terminal screws on the terminal block, insert the
100 VAC : V200-30-1A-
core of the lead wire into the terminal, and attach securely with
the terminal screws.
200 VAC : V200-30-2A- In addition, when using the DC mode type with a surge vol-
tage suppressor (polar: S and Z types), connect wires corre-
sponding to the polarity (+ or –) that is printed on the terminal
AC other voltages: V200-30-3A- block.
4) Tighten the ground nut to secure the wire.
Without lead wire : V200-30-A In the case of connecting wires, select cabtire cords carefully
(With connector and 2 sockets) because if those out of the specified range (ø4.5 to ø7) are
used, it will not be able to satisfy IP65 (enclosure).
Lead wire length Tighten the ground nut and set screw within the specified
Nil 300 mm range of torque.
6 600 mm
10 1000 mm Ground nut
Tightening torque Set screw
15 1500 mm
2.5 to 3.75 N·m Tightening torque
20 2000 mm 0.5 to 0.6 N·m
25 2500 mm
30 3000 mm Washer Housing
50 5000 mm
Grommet
How to Order (Rubber)
Terminal block
Include the connector assembly part number together with the
part number for the plug connector’s solenoid valve without Terminal screw
3 locations
connector. Tightening torque
+ 0.4 to 0.5 N·m
(Example) 2000 mm lead wire length (Location for –
light mounting)
DC AC (Voltage (Polarity indication)
symbol)
VF3130-5LO1-02 VF3130-1LO1-02
V200-30-4A-20 V200-30-1A-20 ∗ Refer to back page 4 for the DIN connector part no.

Changing the entry direction


After separating terminal block and housing, the cord entry
direction can be changed by attaching the housing in the
opposite direction.
∗ Make sure not to damage elements, etc., with the lead wires of
the cord.
Precautions
Plug in and pull out the connector vertically without tilting to one
side.

Applicable cable
Cable O.D.: ø4.5 to ø7
(Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
JIS C 3306

Applicable crimped terminal


O terminal: R1.25-4M that is specified in JIS C 2805
Y terminal: 1.25-3L, which is released by JST Mfg. Co., Ltd.
Stick terminal: Size 1.5 or shorter

Back page 3
VF-B.qxd 10.12.1 9:37 AM Page 55

Series VF
Specific Product Precautions 3
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

DIN (EN175301-803) Terminal How to Use Conduit Terminal


Y type DIN terminal corresponds to the DIN connector with
terminal pitch 10 mm, which complies with EN175301-803B. Caution
Since the terminal pitch is different from the D type DIN
connector, these two types are not interchangeable.
Connection
1) Loosen the set screw and remove the terminal block cover
from the terminal block.
Y type D type 2) Loosen the terminal screws on the terminal block, insert the
core of the lead wire or crimped terminal
10 11 into the terminal, and attach securely with
the terminal screws.
In addition, when using the DC mode type
with a surge voltage suppressor (polar: S
5.5

8.5

and Z types), connect wires to terminal 1 (+) (–)


and 2 corresponding to the polarity (+ or –)
as shown on the right figure.
3) Secure the cord by fastening the ground nut.

In the case of connecting wires, select cabtire cords carefully be-


How to Order DIN Connector cause if those out of the specified range (ø4.5 to ø7) are used, it
will not be able to satisfy IP65 (enclosure).
Caution Tighten the ground nut and set screw within the specified range
of torque.
-2A
 Without indicator light 0 0 -66
DC, AC, Other voltages: V200- -1 V2 Set screw
m bly Tightening torque
ss e
0.5 to 0.6 N·m
ra
 With indicator light c ove
k
loc Terminal block
DC i n al b Grommet cover
Polar type (Z) : V200- -3- e rm (Rubber)
T
Washer
Ground nut Ground terminal
Non-polar type (U) : V200- -5- Tightening torque screw
Rated voltage 2.5 to 3.75 N·m Tightening torque
0.5 to 0.6 N·m
05 24 VDC
06 12 VDC Terminal screw
(2 locations)
Tightening torque
AC (Z) : V200- -7- 0.5 to 0.6 N·m
Connector specification Rated voltage
61 D type 01 100/110 VAC [115 VAC]
63 Y type 02 200/220 VAC [230 VAC] Applicable cable
07 240 VAC Cable O.D.: ø4.5 to ø7
B 24 VAC (Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
JIS C 3306
Circuit diagram with light (Built-in connector)
Applicable crimped terminal
DC (Z) circuit diagram DC (U) circuit diagram O terminal: Equivalent to R1.25-3 that is specified in JIS C 2805
Y terminal: Equivalent to 1.25-3, which is released by JST Mfg.
Co., Ltd.
+ – 1 2 ∗ Use O terminal when a ground terminal is used.

LED R D LED
LED: Light emitting diode LED: Light emitting diode
D: Protective diode R: Resistor
R: Resistor

AC (Z) circuit diagram

Note) The 24 VAC specifications are


NL R the same as those in the DC
(U) circuit diagram.
NL: Neon bulb, R: Resistor
Back page 4
VF-B.qxd 10.12.1 9:37 AM Page 56

Series VF
Specific Product Precautions 4
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Leakage Voltage Light/Surge Voltage Suppressor

Caution Caution
Especially when a resistor and a switching element are used <DC>
in parallel or C-R device (surge voltage suppressor) is used
 Polar type
for the protection of the switching device, note that leakage
voltage will be increased by passing leakage voltage through With surge voltage suppressor (S) Polarity protection diode
the resistor and C-R device. Therefore, suppressor residual
leakage voltage should be as follows. Red (+)

Switching element Coil


Diode
OFF
C R Black (–)
Power Leakage Valve
voltage
Leakage current
 Grommet or L/M-type plug connector
With light/surge voltage suppressor (Z)
DC coil Polarity protection diode

3% or less of the rated voltage Red (+)

Coil
AC coil LED
Black (–)
8% or less of the rated voltage Diode
 DIN or Conduit terminal
With light/surge voltage suppressor (Z) Polarity protection diode
Continuous Duty Diode
(+)
LED
Caution Coil

 If a valve is energized continuously for long periods of time, (–)


the rise in temperature due to heat-up of the coil assembly For DIN type, installed
may cause a decline in solenoid valve performance, reduce in the connector
service life, or have adverse effects on peripheral equipment.
If the valve is energized continuously for long periods of time,  Non-polar type
or the total energizing time per day becomes longer than the With surge voltage suppressor (R)
non-energizing time, use a valve with power saving circuit.
(–) (+)
 When the valve is mounted onto a control panel, take meas-
ures against radiation in order to keep the valve temperature Coil
Varistor
within the specified range.
(+) (–)

 Grommet or L/M-type plug connector


With light/surge voltage suppressor (U)
(–) (+)
LED

Varistor Coil

(+) (–)

 DIN or Conduit terminal


With light/surge voltage suppressor (U)
Varistor
(–) (+)
LED
Coil

(+) (–)
For DIN type, installed
in the connector

• Please connect correctly the lead wires to + (positive) and –


(negative) indications on the connector. (For non-polar type, the
lead wires can be connected to either one.)
• When the valve with polarity protection diode is used, the vol-
tage will drop by approx. 1 V. Therefore, pay attention to the al-
lowable voltage fluctuation (For details, refer to the solenoid
specification of each type of valve).
• Solenoids, whose lead wires have been pre-wired: + (positive)
side red and – (negative) side black.
Back page 5
VF-B.qxd 10.12.1 9:37 AM Page 57

Series VF
Specific Product Precautions 5
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Light/Surge Voltage Suppressor Light/Surge Voltage Suppressor

Caution Caution
 With power saving circuit Residual voltage of the surge voltage suppressor
Power consumption is decreased by approx. 1/3 by reducing Note) if a varistor or diode surge voltage suppressor is used,
the wattage required to hold the valve in an energized state. there is some residual voltage to the protection element
(Effective energizing time is over 40 ms at 24 VDC.) and rated voltage. Therefore, refer to the table below and
Refer to the electrical power waveform as shown below. pay attention to the surge voltage protection on the control-
ler side. Also, since the response time does change, refer
<Electrical power waveform of energy saving type> to the specifications on page 2 and 16.
Residual Voltage
Applied voltage DC
Surge voltage suppressor AC
24 V 24 V 12 V
S, Z Approx. 1 V Approx. 1 V
R, U Approx. 47 V Approx. 32 V —
0V
Countermeasure for Surge Voltage Intrusion

1.55 W
Standard Caution
With non-polar type solenoid valves, at times of sudden interruption
With power saving circuit of the loading power supply, such as emergency shutdown, surge
0.55 W voltage intrusion may be generated from loading equipment with a
large capacity (power consumption), and the solenoid valve in a de-
0W energized state may switch over (see Figure 1).
40 ms When installing a breaker circuit for the loading power supply, consider
using a solenoid valve with polarity (with polarity protection diode), or
install a surge absorption diode between the loading equipment COM
line and the output equipment COM line (see Figure 2).
• Since the voltage will drop by approx. 0.5 V due to the transis-
tor, pay attention to the allowable voltage fluctuation. (For de- Output circuit
tails, refer to the solenoid specifications of each type of valve.) Surge voltage
24 V
0V
Polarity protection diode Diode sol.1: Energized
R –60 V
Internal circuit

Red (+) Surge voltage


Coil 0V
sol.2: De-
PWM circuit

R
energized Surge –60 V
voltage
24 V
0V
Large capacity
LED R
load: Energized –60 V

Black (–)

<AC> Relay
Power supply circuit breaker
There is no S option, since a rectifier prevents surge voltage
24 VDC
generation.
Figure 1. Surge intrusion circuit example (NPN outlet example) (24 VDC)
 Grommet or L/M-type plug connector
With light/surge voltage suppressor (Z) Output circuit
Surge voltage
(~) 24 V
0V
sol.1: Energized –2 V or less
Varistor LED Coil R
Internal circuit

Surge voltage
0V
(~) sol.2: De- –2 V or less
R energized Surge voltage
 DIN or Conduit terminal 24 V
0V
With light/surge voltage suppressor (Z) Large capacity –2 V or less
R
load: Energized
(~) Diode Countermeasure parts

– (Anode) + (Cathode)
Neon bulb Note)
Varistor Coil Relay
Power supply circuit breaker
(~)
For DIN type, installed in the connector 24 VDC
Figure 2. Surge intrusion circuit example (NPN outlet example) (24 VDC)
Note) LED for 24 VAC.
Back page 6
VF-B.qxd 10.12.1 9:37 AM Page 58

Series VF
Specific Product Precautions 6
Be sure to read before handling.
Refer to back page 1 for Safety Instructions, “Handling Precautions for SMC Products”
(M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

One-touch Fittings Precautions

Caution
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings
to be used should first be confirmed in their respective catalogs.
Fittings whose compliance with the VF series is already confirmed are stated below. If the fitting within the applicable range is selected,
there will not be any interference.

Applicable Fittings: Series KQ2H, KQ2S


Applicable tubing O.D.
Series Model Piping port Port size
ø3.2 ø4 ø6 ø8 ø10 ø12 ø16
4(A), 2(B) M5
VF120-1-M5
5(EA), 3(EB) M5
4(A), 2(B) 1/8
VF120-1-01
5(EA), 3(EB) M5
VF1000 VF13-1-M5 4(A), 2(B) M5
VF13-1-01 4(A), 2(B) 1/8
Type 30 manifold base 1(P), 5/3(R) 1/8
1(P) 1/8
Type 31 manifold base
5(EA), 3(EB) M5

Applicable tubing O.D.


Series Model Piping port Port size
ø3.2 ø4 ø6 ø8 ø10 ø12 ø16
4(A), 2(B) 1/8
VF33-1-01
1(P), 5(EA), 3(EB) 1/8
4(A), 2(B) 1/4
VF33-1-02
1(P), 5(EA), 3(EB) P: 1/4, EA, EB: 1/8
4(A), 2(B) 1/4
VF34-1-02
VF3000 1(P), 5(EA), 3(EB) 1/4
4(A), 2(B) 3/8
VF34-1-03
1(P), 5(EA), 3(EB) 3/8
Type 30 manifold base 1(P), 5(R), 3(R) 1/4
4(A), 2(B) 1/4
Type 40 manifold base
1(P), 5(R), 3(R) 1/4

Applicable tubing O.D.


Series Model Piping port Port size
ø3.2 ø4 ø6 ø8 ø10 ø12 ø16
4(A), 2(B) 1/4
VF52-1-02
1(P), 5(EA), 3(EB) 1/4
4(A), 2(B) 3/8
VF52-1-03
1(P), 5(EA), 3(EB) 3/8
4(A), 2(B) 1/4
VF544-1-02
1(P), 5(EA), 3(EB) 1/4
4(A), 2(B) 3/8
VF5000 VF544-1-03
1(P), 5(EA), 3(EB) 3/8
4(A), 2(B) 1/2
VF544-1-04
1(P), 5(EA), 3(EB) 1/2
Type 20 manifold base 1(P), 5(R), 3(R) 3/8
Type 21 manifold base 1(P), 5(R), 3(R) 1/2
4(A), 2(B) 1/4
Type 40 manifold base
1(P), 5(R), 3(R) 3/8

Back page 7
VF-B.qxd 10.12.1 9:37 AM Page 59
VF-B.qxd 10.12.1 9:37 AM Page 60

Revision history
Edition B ∗ Addition of 24 VAC to Rated voltage for Series VF1000/3000/5000.

OZ

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN