Sie sind auf Seite 1von 3

FAS8040

Specifications

8.3.1 clustered Data ONTAP


System Maximums and
Limits
Max Raw capacity (HA) 5760 TB
Max Storage Devices (HA) 720 (drives & array LUNs)
Max Nodes per Cluster (NAS
24 / 8
/ SAN)
Max Aggregate Size 32-bit Not Supported
Max Aggregate Size 64-bit 324 TiB
Max FabricPool Size Not Supported
Min Root Aggregate Size 431 GiB
Max FlexVol Size 32-bit Not Supported
Max FlexVol Size 64-bit 100 TiB
Max Infinite Volume Data
100 TiB
Constituent Size
Max FlexGroup Data
Not Supported
Constituent Size
Max Volume Count (Per
1000
Node)
Min Root Volume Size 350 GiB
NetApp Volume Encryption Not Supported
FlexArray Specifications
Spray Core Array LUNs
Recommended Min Raw 4.39 TiB [1]
Capacity
Spray Core Array LUNs
2.64 TiB [2]
Absolute Min Raw Capacity
Max Array LUN Size 5.72 TiB [4]
Min Array LUN Size 1.05 GiB
Min Size for an Array LUN
80.00 GiB
Aggregate
Min Array LUN Size – Root
634.00 GiB
Volume
Spare Core Array LUN Min
52.00 GiB
Size
Max RAID Groups in an
150
Aggregate
Block Size 512 bytes
Neighborhood Visible and
-
Assigned Devices
Technical Specifications per
HA pair
Processor 2 x 64-bit 8-core 2.10 Ghz
Memory 64 GB
NVRAM 16 GB
8 x RJ45 (1Gb)
Ethernet Ports
8 x SFP+ (10Gb)
Fibre Channel Ports -
UTA2 Ports 8 x SFP+ (10Gb/16Gb) [5]
Expansion Slots 8 x PCIe3
SAS Ports 8 x QSFP (6Gb)
Physical Characteristics
Rack Units 6
Chassis Height 10.2" (25.9 cm)
Chassis Width with
18.94" (48.1 cm)
Mounting Flanges
Chassis Width without
17.6" (44.7 cm)
Mounting Flanges
Chassis Depth with Cable
28.9" (73.4 cm)
Mgmt
Chassis Depth without
24.29" (61.7 cm)
Cable Mgmt
Chassis Weight - One
100.97 lb (45.8 kg)
Controller Module
Chassis Weight - Two
119.49 lb (54.2 kg)
Controllers Module
Chassis Weight - Controller
-
+ IOXM
System Clearance
Dimensions
FAS8040

Specifications

8.3.1 clustered Data ONTAP


Front Clearance (Cooling) 5.99" (15.2 cm)
Front Clearance
30.02" (76.2 cm)
(Maintenance)
Rear Clearance (Cooling) 12.02" (30.5 cm)
Rear Clearance
36.01" (91.4 cm)
(Maintenance)
Environmental
Requirements
Operating Temperature 50 to 104 deg F
Range 10 to 40 deg C
-40 to 158 deg F
Storage Temperature Range
-40 to 70 deg C
-40 to 158 deg F
Transit Temperature Range
-40 to 70 deg C
Operating Relative Humidity 20 to 80 %
Storage Relative Humidity 5 to 95 %
Transit Relative Humidity 5 to 95 %
0.0 to 10000.0 ft
Operating Altitude Range
0.0 to 3048.0 m
0.0 to 40000.0 ft
Storage Altitude Range
0.0 to 12192.0 m
0 to 39989.8 ft
Transit Altitude Range
0 to 12192 m
Acoustic Noise - Sound
7.5 bels
Power
Acoustic Noise - Sound
61.3 dBA
Pressure
Input Power Voltage 100 to 120, 200 to 240
Storage O/S Requirements
8.2.1RC2, 8.3RC1, 9.0RC1, 9.1RC1,
Min ONTAP version
9.2RC1, 9.3RC1,
8.2.5, 8.3.2, 9.0P4, 9.1P14, 9.2P4,
Max ONTAP version
9.3P7, 9.4P2
System Availability &
Support
EOA 31-Dec-2017
EOS 31-Jan-2023
Notes ID Notes Description
A spray core occurs when there is no suitable spare core or if the spare core increase disruption time, then the system
attempts to stripe the coredump over the non-file system region of multiple array LUNs. For a spray core to operate, a
1 minimum total capacity of array LUNs assigned to the system is required which is defined by this value. If greater than 2 TiB
array LUNs are used, the required capacity is increased five times because the non-file system region is a smaller percentage
of the total space (0.2% compared to 1%).
A spray core occurs when there is no suitable spare core or if the spare core increase disruption time, then the system
attempts to stripe the coredump over the non-file system region of multiple array LUNs. If there is no enough capacity
available as per the Spray Core Array LUNs Recommended Min Raw Capacity (GiB) attribute value, the system attempts to
2 first compress the data before spraying. Assuming 60% compression, the system should have at least the total assigned
capacity as per the Spray Core Array LUNs Absolute Min Raw Capacity (GiB) attribute value for a compressed spray core to
work. If greater than 2 TiB array LUNs are used, the required capacity is increased five times because the non-file system
region is a smaller percentage of the total space (0.2% compared to 1%)”.
The FAS80x0 onboard UTA2 ports and X1143A UTA2 ports are not supported for connectivity to DS14 shelves. To connect to
3
DS14 shelves, use the X1132A-R6 or X2054A-R6 Fibre Channel adapters.
The maximum LUN size provided is a number determined by the V-Series/FlexArray product team. Supported maximum LUN
4
size will be the lesser of published maximum LUN size by NetApp and maximum LUN size supported by the backend array
The onboard UTA2 ports can be configured as FC Target/Initiator or CNA (FCoE target/Ethernet). The UTA2 ports are based
on a dual port ASIC and both ports on each ASIC must be set to the same mode (enforced by Data ONTAP). Install X6599A-
5
R6 10GbE SFP+ modules or approved copper twinax cables when using in CNA (FCoE target/Ethernet) mode. Install X6596-
R6 16Gb FC SFP+ module when using in FC Target/Initiator mode.