SB # 1266

Title Line Filter for DM-TR20 Turret Controller

Rev. A

FSB/SWB/TIN Ref#

Action Mandatory

Date 7/26/2018

By Wayne Kline

Approved David Skrzypczak

Status Approved

Category Electrical

Model(s) TMX8MYi, TMX8MYSi


TMX10MYi, TMX10MYSi
Control WinMax

SW Version Not Applicable

Issue Ref Service Issue 4891; CRF 1064

Description Machines listed in effectivity did not have a line filter for the Turret Controller.
On these units, the line power for the Turret Controller was wired into the
Rexroth filter. It is mandatory that the frames listed in the effectivity section
are retrofitted with a new line filter for the Turret Controller.

Machines wired this way may have an "Alarm 7: IGBT Failure or high current"
or the Turret Controller may fail completely. WinMax will report the following
error message:
ALARM: Turret Controller Fault detected.
Controller reports Short circuit on power stage: check servomotor wiring or
motor or controller may have internal damage.

A change has been implemented in manufacturing to add a new line filter for
the Turret Controller and no longer use the Rexroth filter for this device.

Please order and install the parts listed in the Materials section below and use
the appropriate schematic drawing (for MY or MYS models) to install the parts.

For frames that have the new filter, confirm that the Turret Controller filter is
not connected to the Rexroth filter.
Tables, Charts

Effectivity Add the new filter to the following frames:


TMX8MY: None
TMX8MY VDI: HTYV80001~8

https://partner.hurco.com/CQ/Lists/Service%20Bulletins/DispForm.aspx?ID=1266 8/24/18
Service Bulletins - Line Filter for DM-TR20 Turret Controller... Page 2 of 2

TMX8MYS: HTS80054
TMX8MYS VDI: HTSV80001~0007

TMX10MY: HTY100017
TMX10MY VDI: HTYV10001~3

TMX10MYS: HTS100019~0021
TMX10MYS VDI: HTSV100001~0006
Materials 409-0001-030; Filter, Noise 3 Phase, 10 Amp, 1 ea.
110-0046-005; LOCKWASHER, M4 HELICAL SPRING, 4 ea.
109-5024-003; PPHMS, M4 X 0.7 X 8MM LG, 4 ea.
Software Requirements Not Applicable

Procedure Wire the new line filter per the attached schematics, (Wiring Changes.pdf).
Confirm that the turret line filter is not connected to the Rexroth line filter as
shown in the attached, (004-1810-011 Rev C is Correct.pdf).

TMX8MY/TMX10MY; MY_004-1810-016-3.pdf, (Rev. B or greater).


TMX8MYS/TMX10MYS; MYS_004-1810-011-3.pdf, (Rev. B or greater).
Operation Notes

Reference(s) 004-1810-016; SCHEMATIC, ELECTRICAL, ITX, TMX8/10MY LCM SP, (Rev. B or


greater)

004-1810-011; SCHEMATIC, ELECTRICAL, ITX, TMX8/10MYS LCM SP, (Rev. B


or greater)
Revision Notes Rev A, 23Jul18, by W.Kline, approved by D.Skrzypczak

Fig.1

Fig.2

Fig.3

Fig.4

Fig.5

Fig.6

Fig.7

Fig.8

Fig.9

Fig.10

Assigned To

Attachments 004-1810-011 Rev C is Correct.pdf


SB1266_Line Filter for DM-TR20 Turret Controller.pdf
Wiring Changes.pdf

Version: 15.0
Created at 4/10/2017 8:52 AM by Kline, Wayne
Last modified at 8/22/2018 9:36 AM by Stroup, Julie

https://partner.hurco.com/CQ/Lists/Service%20Bulletins/DispForm.aspx?ID=1266 8/24/18
Correct

X X

X' X'

S1 S1

Z Z

S2 S2

W W
FAN

S3 S3

IN IN

H U R C O C O M P A N I E S , I N C ., IN D I A N A P O L IS , I N D IA N A 4 6 2 6 8 , U S A

New Filter
Remove wires 410, 412 and 414 from this
line filter and wire to 401, 402 and 403.
Relabel both ends of wires.

Relabel as 401, 402 and 403.

Add Line Filter