Sie sind auf Seite 1von 2

Ultrasonic sensors

Ultrasonic distance measuring UNDK 30U9112/S14


sensors
dimension drawing

30 31,1
LED Pot 18,4

23
65
37,4
4,5

11

M12 x 1 11,4
20 14

general data photo


scanning range Sd 60 ... 400 mm
scanning range far limit Sde 60 ... 400 mm
repeat accuracy < 0,5 mm
resolution < 0,3 mm
response time ton < 60 ms
release time toff < 60 ms
temperature drift < 2 % of distance to target So
sonic frequency 400 kHz
adjustment potentiometer
alignment aid target indication flashing
light indicator LED green

electrical data
voltage supply range +Vs 15 ... 30 VDC connection diagram
current consumption max. (no load) 35 mA
output circuit voltage output BN (1 )
+VS
output signal 0 ... 10 VDC
output current < 20 mA BK (4 )
Analog output
residual ripple < 10 % Vs Z
BU (3 )
short circuit protection yes 0V

reverse polarity protection yes

mechanical data
type rectangular
housing material polyester / die-cast zinc
width / diameter 30 mm Analog voltage output 0 - 10 V
height / length 65 mm
depth 31 mm
connection types connector M12

ambient conditions
operating temperature -10 ... +60 °C
protection class IP 67

UNDK 30U9112/S14 www.baumer.com 20/9/2018


Ultrasonic sensors

Ultrasonic distance measuring UNDK 30U9112/S14


sensors
typical sonic cone profile

50
lateral distance to reference axis (mm)

40

30

20

10

-10

-20

-30
sensing limit
-40

-50
0 50 100 150 200 250 300 350 400 450 500

object distance (So) from sensor front (mm)


standard target with 30 x 30mm, directed rectangular to sensor's reference axis

UNDK 30U9112/S14 www.baumer.com 20/9/2018