Protective Coating for HVAC/R Coils
Once corrosion starts to develop,
a unit’s capacity decreases rapidly
resulting in reduced efficiency and
increased energy consumption. In
some conditions, the operating
performance of unprotected coils
can decrease by over 30% in less
than 6 months.

The SOLUTION is
BLYGOLD PoluAl:
Exposed to Corrosion Blygold PoluAl is a metallic
impregnated polyurethane coating
specifically designed for
application to aluminum finned-
copper tube coils. It is a thin (25
microns), flexible, UV and impact
resistant coating that exhibits
excellent adherence to aluminum
surfaces. PoluAl protects the
parent metal against a wide range
of corrosive salts, acids, and other
elements found in the atmosphere
and provides protection superior
Protected with PoluAl to that of Cu/Cu coils.
BLYGOLD: In addition to a superior ability
Blygold was established in the to resist corrosion, the unique
Netherlands over twenty-five years characteristics of PoluAl result in it
ago in response to a market having only a negligible effect on
demand for more effective coating pressure drop, and heat transfer
products for HVAC/R applications. (k value) of the coated coil. The
From its origin, Blygold has been HVAC/R unit coated with PoluAl
developing protective coatings receives all the benefits of
specifically engineered for HVAC/R corrosion protection without losing
coils and equipment that are operating efficiency.
installed in corrosive marine and
industrial environments.
The unique capabilities of
Blygold products combined with
Blygold’s global network of
licensed applicators, have made
Blygold the global leader in the
protective coatings market for
HVAC/R coils.

The PROBLEM is
CORROSION:
Coil manufacturers are continually
designing more efficient coils by 3-YEAR WARRANTY:
utilizing higher fin densities and Blygold guarantees protection for
enhanced fin geometries. As a HVAC/R coils with a standard 3-
result, increasingly thinner metals year conditional warranty for
are utilized that have greater Blygold PoluAl applied on
surface exposure to corrosive aluminum-finned, copper-tube
influences. coils by certified Blygold licensed
applicators.

Protective Coatings for HVAC/R Coils & Equipment


When HVAC/R equipment is
installed near coastal or industrial
areas, the coil’s finned surfaces are
exposed to salts and other
corrosive substances as air passes
through the coils during operation.
www.blygoldamerica.com
BLYGOLD PoluAl
1
Field of Application:
Applicable to aluminum-
finned, copper-tube condenser/
evaporator coils and heat
exchanger coils.
Protective Coating for HVAC/R Coils
Typical Applications:
• Coastal, Marine, & Offshore
Environments Advantages: Application Process:
• Waste Water Treatment 1. Inspection & Cleaning
Facilities UV Resistant 2. Fin Alignment

2
• Pulp & Paper Mills 3. De-Oxidizing
• Mining & Drilling Operations Highly Flexible 4. Rinsing
Aluminum 5. Conversion Layer
• Refineries & Heavy Impregnated Sheds Water
Manufacturing 6. Drying
Polyurethane 7. PoluAl Topcoat
• Pharmaceutical & Chemical Negligible
Plants Effect on Heat
• Semiconductor & Photo Film Transfer
PoluAl Specification:
Manufacturing (k value)
• Meat & Dairy Processing Aluminum Impregnated
• Hog & Mushroom Farms No Cracking or Polyurethane Coating:
Superior Flaking The coating manufacturer shall be able

3
• Swimming Pool Applications
Adhesion to document the successful completion
• Commercial Refrigeration Highly Impact of accelerated product testing of a
• Various Other Corrosive Resistant minimum 3000 hours in both salt spray
Environs
(ASTM B117) and acid salt spray tests
Covers All
(ASTM G85); and shall be able to
Characteristics: 100% Finned Surface
Coverage Area and Cut provide a 3-year conditional warranty
Conversion Layer Chromate Free Edges for the coating applied on aluminum-
finned, copper tube coils. The product
Metallic No Bridging application process shall include the
Topcoat Impregnated application of a chromate-free conversion

4
Polyurethane Extremely Negligible layer applied to the coil that achieves total
Thin Effect on coverage and penetration. An aluminum-
Color Silver Pressure Drop impregnated polyurethane topcoat shall be
applied that ensures total penetration
20–25 Microns Years of
Successful and coverage without bridging or
Dry Film =
Thickness 1 Mil Field Tested PoluAl significantly affecting the heat transfer
(Approximately) Corrosion Applications in ability of the coil. The total dry film
Protection over 30 thickness of the topcoat shall be 20 to
Temperature up to 194° F Countries 25 microns (0.020 to 0.025 mm). The
Rating (up to 90° C) coating shall provide protection
Corroded Coils against ultraviolet radiation and be

5
pH Range 3 – 12 Cause Rapid temperature resistant up to 194°F (90°C).
Energy Declines in
Cross Hatch Savings HVAC/R Energy
Adhesion 4B – 5B Efficiency Some Organizations
ASTM D5339 Using Blygold PoluAl:
Fast Turn-
Accelerated Testing: Around Time • Carrier
• Trane
Salt Spray Test Able to Coat • Lennox
ASTM B117 3000 Hours + Application Most Units • York
Process Without • McQuay
Acid Salt Spray Removing Coils
• Mitsubishi

6
Test
ASTM G85 3000 Hours + Environmentally • Shell
(Formerly - B287) Safe • ARAMCO
• IBM
Kesternich • KLM
DIN 50018- Warranty 3-Year Standard • Verizon
SFW 2.0S 80 Cycles (Conditional) • State of Hawaii
(2 liters SO2) • U.S. Army
• U.S. Air Force
• U.S. Navy
• U.S. Marine Corps

Blygold America, Inc.


P.O. Box 759
Stevensville, MD 21666
Phone: 410-643-6080
7
Fax: 410-643-6092
Email: info@blygoldamerica.com

Das könnte Ihnen auch gefallen