V100R012C10SPC330 (GBTS)
Upgrade Guide (SMT-Based)
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Purpose
This document describes how to upgrade a base station to BTS3900 V100R012C10SPC330
and how to roll back the upgrade using the SMT. It also provides FAQs and troubleshooting
methods.
Intended Audience
This document is intended for upgrade personnel. Upgrade personnel must:
Be familiar with the product networking and related NEs' versions.
Have device maintenance experience and be familiar with device operation and
maintenance.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Change History
Issue Date Description
Owners
Prepared By GSM software development team Date 2018-03-20
Contents
6 FAQs...............................................................................................................................................24
6.1 How Does the Password for Logging In to the SMT Change Before and After an Upgrade or Rollback?.................24
6.2 What Are the Categories of BTS Boards?....................................................................................................................25
6.3 How Do I Upgrade Monitoring Boards?......................................................................................................................26
6.3.1 Loading Software for the Monitoring Board.............................................................................................................26
6.3.2 Activating Software for the Monitoring Board.........................................................................................................27
6.4 How Do I Set the Load Control Rights for a Multimode Base Station?......................................................................28
6.5 How Do I Back Up the BTS Software Using the U2000?...........................................................................................29
6.6 How Do I Handle a BTS Software Download Failure?...............................................................................................29
6.7 How Do I Handle a BTS Software Activation Failure?...............................................................................................30
6.8 How Do I Release the Site Management Rights Manually?........................................................................................31
6.9 How Do I Make Upgrade Software Packages Using SRAN Software Packages?.......................................................31
6.10 How Do I Download the BTS Upgrade Software Package to the BSC?...................................................................31
A Appendix......................................................................................................................................32
A.1 Upgrade Record...........................................................................................................................................................32
A.2 Verification Record of GBTS Services........................................................................................................................33
If the GUI language is not the target language, select the target language on the top of the page.
Method 2
Log in to http://support.huawei.com using a Huawei engineer's account, enter
"BTS3900" in the Search text box of the Software tab page, and click the result that is
automatically displayed. Then, click the target version in the displayed interface.
Step 2 Download the upgrade software package and reference document from the version release
path.
This document assumes that the decompressed files are saved in D:\FTP.
After Download.zip is decompressed, do not delete or move any file in the software package to retain
the integrity of the software package and avoid software loading failure.
You can disable automatic loading and activation for multiple BTSs by running the following commands
in batches:
SET BTSAUTODLDACTINFO: IDTYPE=BYID, BTSID=18, ADLDACT=OFF;
For details about how to set the IP address of the PC running the SMT, see the online help of the
Windows operating system.
If the message "The trust certificate has expired" is displayed in the lower left corner of the dialog
box, and the GTMUc is connected through the SMT, click Update Digital Certificate. In the
displayed Update Digital Certificate dialog box, choose the trust certificate and certificate
revocation list to be updated and click Update. You can download the trust certificate Wireless
Network Product CA Chain.pem and certificate revocation list WNCA_crl.crl from Huawei
Wireless Network Product CA Certificates and CRL.
When the SMT fails to be connected to the BTS, check whether the IP address of the PC running the
SMT configured and the IP address entered into the BTS IP Address area are correct. If they are
correct and the BTS is properly connected to the BSC, run the DSP BTSLOCALETHPORT
command to query the value of Port Configuration Status in the command output. If the value is
Disable, run the SET BTSLOCALETHPORT command with Maintenance Port Switch set to
ENABLE(Enable).
The default user name and password for logging in to the SMT are admin and hwbs@com,
respectively.
Users can log in to the BSC LMT and run the SET BTSUSERPWD command to change the
password, with Username and Password Type set to USER_SELF_DEFINE, Username set to
admin (each letter of the admin can be capitalized), and Encrypted Mode set to ENCRYPTED.
----End
If the Board Management dialog box does not display any boards, click Refresh in the lower part of
the dialog box.
2. Record the software version, as shown in Figure 2-3.
3. Click OK.
Step 3 Query and record the TRX software version.
1. In the Board Management dialog box, double-click GTMU.
The Topology Management dialog box is displayed.
If the TRX board is connected to the UBRI or UBBP, double-click the UBRI or UBBP. The Topology
Management dialog box is displayed.
2. In the Topology Management dialog box, right-click the TRX board to be queried (for
example, GRRU) and choose Board Information from the shortcut menu.
The Board Information dialog box is displayed.
If the Board Management dialog box does not display any boards, click Refresh in the lower part of
the dialog box.
3. Record the software version, as shown in Figure 2-4.
4. Click OK.
Step 4 Query and record the software versions of monitoring boards.
1. In the Board Management dialog box, right-click EMU and choose Board
Information from the shortcut menu.
The Board Information dialog box is displayed.
2. Record the software version, as shown in Figure 2-5.
3. Click OK.
4. In the Board Management dialog box, click Close.
----End
For details about how to save KPI reports on the U2000, see U2000 online help by performing the
following steps:
On the U2000, press F1. The U2000 Online Help window is displayed.
Choose Performance Management > Performance Measurement Management > Performance
Management During Routine Maintenance > Exporting NE Performance Measurement
Results. Then, save the NE performance measurement results.
Before upgrading one mode of a multimode base station, check the status of the peer mode by
following the instructions in the upgrade verification description in the corresponding upgrade
guide. If the working status of the peer mode is abnormal, rectify the faulty before performing
the upgrade.
Step 2 Right-click in the displayed alarm list and choose Save Message from the shortcut menu to
save the alarm information.
----End
This chapter uses GTMU, GRRU, and UBRI as examples to describe the BTS upgrade
procedure on the SMT.
Table 3-1 lists the operations and durations of the BTS upgrade on the SMT.
You can load the GTMU software only after the software of the TRX boards and boards in
the BBU subrack is loaded. You can activate the GTMU software only after the software
of the TRX boards and boards in the BBU subrack is activated. There is no restriction on
the sequence of loading or activating software for the TRX boards or the boards in the
BBU subrack.
All configured BTS boards (except for monitoring boards) must be upgraded during a BTS
upgrade. You can determine whether to upgrade monitoring boards according to the
precautions released by Huawei. If you need to upgrade monitoring boards after upgrading
the non-monitoring boards, see 6.3 How Do I Upgrade Monitoring Boards?
When the BTS is connected to the BSC and you have obtained the site management rights,
to avoid BTS resets do not run configuration commands.
Do not reset boards during software loading and activation.
----End
Skip this section if the BTS is not configured with the UBRI.
Step 2 In the Software Download dialog box, set parameters as follows, as shown in Figure 3-2:
1. In the File Name area, click Browse and select the ubridown.pck file under the
directory (described in 2.2 Obtaining Upgrade Reference Documents and Upgrade
Software) where the upgrade software package is saved.
2. In the Version area, enter BTS3900V100R012C10SP330 in the first text box.
3. Select UBRI_MAIN from the File ID drop-down list.
The .pck file selected in the File Name area must be the .pck file of the board to be loaded.
The board type selected in the File ID area determines the board file to be loaded. Therefore, setting
File ID to an improper value may lead to failure in downloading or activating board software.
Step 4 When the download progress reaches 100% and the "Downloading software successfully"
message is displayed, click Close.
If the BTS software downloading fails, perform operations according to 6.6 How Do I Handle a BTS
Software Download Failure?
----End
The .pck file selected in the File Name area must be the .pck file of the board to be loaded.
The board type selected in the File ID area determines the board file to be loaded. Therefore, setting
File ID to an improper value may lead to failure in downloading or activating board software.
If the BTS software downloading fails, perform operations according to 6.6 How Do I Handle a BTS
Software Download Failure?
----End
The .pck file selected in the File Name area must be the .pck file of the board to be loaded.
The board type selected in the File ID area determines the board file to be loaded. Therefore, setting
File ID to an improper value may lead to failure in downloading or activating board software.
If the BTS software downloading fails, perform operations according to 6.6 How Do I Handle a BTS
Software Download Failure?
----End
Step 3 Click OK. Then the software download starts from GTMU flash memory to TRX board, as
shown in Figure 3-3.
Step 4 When the download progress reaches 100% and the "Board downloading complete" message
is displayed on the lower left of the dialog box, click Close.
If the BTS software activation fails, perform operations according to 6.7 How Do I Handle a BTS
Software Activation Failure?
----End
Skip this section if the BTS is not configured with the UBRI.
Step 3 Click OK. The status bar displays "Software activation confirmed." Then the software
download starts from GTMU flash memory to UBRI board.
Step 4 When the download progress reaches 100% and the "Board downloading complete" message
is displayed on the lower left of the dialog box, click Close.
If the BTS software activation fails, perform operations according to 6.7 How Do I Handle a BTS
Software Activation Failure?
----End
If the BTS software activation fails, perform operations according to 6.7 How Do I Handle a BTS
Software Activation Failure?
The site management rights are automatically released after the GTMU software is activated. To
manually release the site management rights before the GTMU software is activated, perform
operations according to 6.8 How Do I Release the Site Management Rights Manually? To obtain the
site management rights, perform operations according to 3.1 Obtaining the Site Management Rights.
Wait four minutes for the services to recover. During the reset period, the SMT is
temporarily disconnected with the BTS. After the SMT is reconnected to the BTS, if the
target software version of the GTMU can be queried on the SMT, the GTMU software is
successfully activated. For information about how to query software versions on the SMT,
see 2.5 Querying the GBTS Version.
After the software is successfully activated and the BTS is reset, do not disconnect the
network cable between the SMT and BTS and do not disable the SMT before the SMT is
successfully connected to the BTS. Otherwise, the BTS automatically rolls back to the
source version.
After the upgrade, the password for logging in to the SMT may change depending on the
BTS versions before and after the upgrade. For details, see 6.1 How Does the Password for
Logging In to the SMT Change Before and After an Upgrade or Rollback?
----End
Before enabling automatic loading and activation, ensure that the BTS3900
V100R012C10SP330 software package has been downloaded to the BSC. Otherwise, the
BSC may reset the BTS during version verification after automatic loading and activation is
enabled. For information about how to download the BTS software package to the BSC, see
6.10 How Do I Download the BTS Upgrade Software Package to the BSC?
The values for Auto Download Mode include Common Download, Quick Download No Traffic and
Quick Download Reserve BCCH. In IP transmission mode, services are properly provided during the
loading process in these values for Auto Download Mode. In TDM transmission mode, these values for
Auto Download Mode differ as follows:
COMMON_DLD (Common Download): If BTS Multiplexing Mode or BCCH TRX RSL
Multiplexing Mode is set to MODE2_1, MODE3_1, MODE4_1, MODE5_1, or MODE6_1, you
are advised to load software during off-peak hours. Otherwise, services may be affected.
QUICK_DLD1 (Quick Download No Traffic): Software loading interrupts services on all TRXs.
QUICK_DLD2 (Quick Download Reserve BCCH): Software loading interrupts services only on
non-BCCH TRXs.
Step 2 Check the returned message to confirm that automatic loading and activation was enabled.
You can enable automatic loading and activation for multiple BTSs in batches by running the following
commands:
SET BTSAUTODLDACTINFO: IDTYPE=BYID, BTSID=18, ADLDACT=ON,
AUTOTYPE=BTSAUTODLDACT, ADVER1="BTS3900V100R012C10SP330",
ADMODE=COMMON_DLD;
SET BTSAUTODLDACTINFO: IDTYPE=BYID, BTSID=19, ADLDACT=ON,
AUTOTYPE=BTSAUTODLDACT, ADVER1="BTS3900V100R012C10SP330",
ADMODE=COMMON_DLD;
...
----End
After the upgrade, follow the instructions in this chapter to verify the upgrade.
After monitoring boards (PMU, EMU, FMU, TCU, GATM, FAN ,BDU,MEB,CCU and so
on) are upgraded, the board software versions may be inconsistent with the BTS software
version.
You must perform the rollback on the SMT released with BTS3900 V100R012C10SPC330.
If the upgrade fails or the network performance seriously deteriorates after the upgrade,
the version requires a rollback. The manual rollback depends on the actual situations of the
network and customer requirements.
For a multimode base station, if any mode in a multimode base station needs to be rolled
back, roll back all the modes to the source versions.
During the rollback, do not reset the base station or any board, power off the base station,
or remove any board. Doing so will cause the rollback to fail.
If the network was adjusted after the base station upgrade, contact Huawei technical
support when rolling back the base station software version.
After the rollback, the password for logging in to the SMT may change depending on the BTS
versions before and after the upgrade as well as the password change status. For details, see
6.1 How Does the Password for Logging In to the SMT Change Before and After an Upgrade
or Rollback?
6 FAQs
Table 1.2 Mapping between passwords for logging in to the SMT and BTS versions
BTS Version Default Default BTS Version
User Name Password Identifier
For details about the passwords for logging in to the SMT before and after the upgrade, see
Table 6-2.
Table 1.3 Mapping between BTS versions and passwords for logging in to the SMT after the
upgrade
BTS Version BTS Version Whether the Login Password After
Before After Password Changed BTS Upgrade
Upgrade Upgrade Before BTS
Upgrade
For details about the passwords for logging in to the SMT before and after the rollback, see
Table 6-3.
Table 1.4 Mapping between BTS versions and passwords for logging in to the SMT before and
after the rollback
BTS Version BTS Version Whether the Login Password After
After Before Password Changed BTS Rollback
Upgrade Upgrade After BTS Upgrade
(Target
Rollback
Version)
Step 3 In the displayed Software Download dialog box, set the parameters as follows:
1. In the File Name area, click Browse and select the file (for example, the
demudown.pck file) under the directory (described in 2.2 Obtaining Upgrade Reference
Documents and Upgrade Software) where the upgrade software package is saved.
2. In the Version area, enter BTS3900V100R012C10SP330 in the first text box.
3. Select EMU_MAIN from the File ID drop-down list.
The operations for upgrading other monitoring boards are similar to those for upgrading the EMU.
For information about how to specify File Name, see Table 6-4
Specify File ID based on the actual board type. The board type selected in the File ID area
determines the board file to be loaded. Therefore, setting File ID to an improper value will lead to
failure in downloading board software.
If the BTS software downloading fails, perform operations according to 6.6 How Do I Handle a BTS
Software Download Failure?
----End
The operations for activating other monitoring boards are similar to those for activating the EMU.
Specify File ID based on the actual board type.
If the BTS software activation fails, perform operations according to 6.7 How Do I Handle a BTS
Software Activation Failure?
Wait six minutes for the EMU services to recover. If the target software version of the
EMU can be queried on the SMT, the EMU software is successfully activated. For
information about how to query software versions on the SMT, see 2.5 Querying the
GBTS Version.
After monitoring boards are upgraded, the board software versions may be inconsistent
with the BTS software version.
Step 5 Release the site management rights. For information about how to release the site
management rights, see 6.8 How Do I Release the Site Management Rights Manually?
----End
If the loading control rights belong to the GSM mode, select Get Control. If the loading control
rights belong to the LTE or UMTS mode, select Release Control.
For details about the mode that has the loading control rights, see Appendix 1Version Mapping
Information in the directory Release Notes\Multimode Base Station Release Notes\Release Notes
(Word_Excel) in the document package delivered with the software version of the multimode base
station.
2. Select Unimmediately Effect in the Effect Software Control area.
3. Enter the GBTS running version in the SelfVersion text box.
4. Enter the running version of the peer NodeB or eNodeB as required in PeerVersion.
To query the version of the peer mode, click Query in the Software Control dialog box.
5. Set Control Mode to GU(GU) or GL(GL).
Application style: Click . On the displayed Application Center tab page, double-
click Software Management, choose NE File > Software Browser.
Traditional style: Choose Software > Software Browser.
Step 2 On the Software Browser tab page, click the OSS Server tab, and select GBTS in the
navigation tree, as shown in Figure 6-2.
Step 3 On the Software tab page, select the software version to be backed up from the Version
column, as shown in Figure 6-2.
If the BTS software version to be backed up is not displayed in the Version column, log in to Huawei
support website to download the required software to your portable.
Step 4 Click Transfer, and choose From OSS Server to OSS Client from the drop-down list.
Step 5 In the displayed NE File Transfer dialog box, select a directory on the portable to which the
software is backed up. Then, click OK.
The system starts to download the software to be backed up from the U2000 to the portable.
On the FTP Task tab page, the download progress is displayed. When the progress reaches
100%, the backup of the BTS software is successfully downloaded to the portable.
----End
1 Failed: Foreground If this happens, verify that the upgrade software package to
reception halted be loaded is intact.
2 The loading status Reload the BTS software or reset the BTS and then reload
is incorrect the BTS software. If the software still fails to be loaded,
contact Huawei technical support.
After Download.zip is decompressed, do not delete or move any file in the software package to retain
the integrity of the software package and avoid software loading failure.
----End