1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

Standby Power Rating


600 kW, 750 kVA, 60 Hz

Prime Power Rating*


540 kW, 675 kVA, 60 Hz

*Assembled in the USA using


domestic and foreign parts

*EPA Certified Prime ratings are not available in the US or its Territories
Image used for illustration purposes only

Codes and Standards Powering Ahead


Generac products are designed to the following standards: Generac Bi-Fuel™ generators start on diesel fuel and add natural gas as load is applied
until the unit runs primarily on natural gas. Generac’s Bi-Fuel generators are fully
UL2200, UL508, UL142, UL489 integrated solutions, not aftermarket conversions in the field. That means every
component is specifically designed, engineered and factory-validated to work together.
Generac Bi-Fuel generators have the added benefit of being EPA-compliant from the
factory.
CSA 22.2
RISK MITIGATION VIA FUEL REDUNDANCY
TM

BS5514 and DIN 6271 Because nobody can predict how long a power outage will last, many diesel-fueled
standby power systems are sized for extended running times. Nevertheless, onsite
diesel fuel supplies are limited, and infrastructure damage could make refueling
difficult. Generac Bi-Fuel generators make the most of an onsite diesel fuel supply by
SAE J1349 running primarily on natural gas. That means less onsite diesel fuel is required and
®

running times will be greatly extended compared to diesel-only solutions. And because
the natural gas infrastructure tends not to be affected by the same conditions that lead
NFPA 37, 70, 99, 110 to power outages, fuel reliability is improved.

® LOWER TOTAL COST OF OWNERSHIP


NEC700, 701, 702, 708 Because natural gas costs less than diesel, fuel costs are significantly reduced over
the long term. And since less onsite diesel fuel is required for long running times,
installation, operational and maintenance costs are reduced.
ISO 3046, 7637, 8528, 9001
SCALABILITY AS PART OF A MODULAR POWER SYSTEM
Generac Bi-Fuel generators can be configured as part of a Modular Power System
NEMA ICS10, MG1, 250, ICS6, AB1 (MPS)—connected via integrated paralleling with other Generac generators. This
makes the system scalable, meaning there is no need to install more power than you
SPEC SHEET

ANSI C62.41 need.

IBC 2009, CBC 2010, IBC 2012, CODE COMPLIANCE


Generac Bi-Fuel generators meet the onsite fuel requirements for emergency systems
ASCE 7-05, ASCE 7-10,
as referenced in NEC700 and NFPA 110. Less onsite diesel fuel means easier
ICC-ES AC-156 (2012) permitting. And indoor fuel installations with capacity limits per NFPA or local codes
Codes or standards compliance listing may not be available with all configurations. Contact factory for details. become a viable option. 1 of 6
1 of 6
SB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

STANDARD FEATURES

ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE (If Selected)


• Oil Drain Extension • Class H Insulation Material • Rust-Proof Fasteners with Nylon Washers to Protect
• Air Cleaner • 2/3 Pitch Finish
• Fan Guard • Skewed Stator • High Performance Sound-Absorbing Material
(Sound Attenuation Enclosure)
• Stainless Steel Flexible Exhaust Connection • Permanent Magnet Excitation
• Gasketed Doors
• Critical Exhaust Silencer (Enclosed Only) • Amortisseur Winding
• Stamped Air-Intake Louvers
• Factory Filled Oil and Coolant • Sealed Bearing
• Upward Facing Discharge Hoods (Radiator and
• Engine Coolant Heater • Full Load Capacity Alternator Exhaust)
• Stainless Steel Lift Off Door Hinges
Fuel System GENERATOR SET • Stainless Steel Lockable Handles
• Primary and Secondary Fuel Shutoff • Internal Genset Vibration Isolation • RhinoCoat™ - Textured Polyester Powder Coat Paint
• Primary and Secondary Fuel Filters • Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers TANK (If Selected)
Cooling System • Wrapped Exhaust Piping (Enclosed Only) • UL 142
• Closed Coolant Recovery System • Standard Factory Testing • Double Wall
• UV/Ozone Resistant Hoses • 2 Year Limited Warranty (Standby Rated Units) • Vents
• Factory-Installed Radiator • 1 Year Limited Warranty (Prime Rated Units) • Sloped Top
• 50/50 Ethylene Glycol Antifreeze • Silencer Mounted on the Discharge Hood • Sloped Bottom
(Enclosed Only) • Factory Pressure Tested (2 psi)
Electrical System • Rupture Basin Alarm
• Battery Charging Alternator • Fuel Level
• Battery Cables • Check Valve in Supply and Return Lines
• Battery Tray • RhinoCoat™ - Textured Polyester Powder Coat Paint
• Rubber-Booted Engine Electrical Connections • Stainless Hardware
• Solenoid Activated Starter Motor

CONTROL SYSTEM • Auto/Off/Manual Switch • Engine Speed


• E-Stop (Red Mushroom-Type) • Battery Voltage
• NFPA110 Level I and II (Programmable) • Frequency
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol Alarms and Warnings
• Predictive Maintenance Algorithm • Oil Pressure
• Sealed Boards • Coolant Temperature
• Password Parameter Adjustment Protection • Coolant Level
• Single Point Ground • Low Fuel Pressure Alarm
• 16 Channel Remote Trending • Engine Overspeed

Digital H Control Panel—Dual 4x20 Display • 0.2 msec High Speed Remote Trending • Battery Voltage
• Alarm Information Automatically Annunciated on the • Alarms and Warnings Time and Date Stamped
Program Functions Display • Snap Shots of Key Operation Parameters During
• Programmable Crank Limiter Alarms and Warnings
Full System Status Display •
• 7-Day Programmable Exerciser Alarms and Warnings Spelled Out (No Alarm Codes)
• Special Applications Programmable Logic Controller
• Power Output (kW)

• RS-232/485 Communications
• Power Factor
• kW Hours, Total and Last Run
SPEC SHEET

• 3-Phase Sensing Digital Voltage Regulator


• 2-Wire Start Capability
• Real/Reactive/Apparent Power

• Date/Time Fault History (Event Log)


• All Phase AC Voltage

• Isochronous Governor Control


• All Phase Currents

• Waterproof/Sealed Connectors
• Oil Pressure

• Audible Alarms and Shutdowns


• Coolant Temperature

• 2 of 6
Not in Auto (Flashing Light)
• Coolant Level 2 of 6
SB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

CONFIGURABLE OPTIONS

ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM


○ Air Filter Restriction Indicator ○ GenLink® Communications Software (English Only) ○ NFPA 110 Compliant 21-Light Remote Annunciator
○ Stone Guard (Open Set Only) ○ Extended Factory Testing ○ Remote Relay Assembly (8 or 16)
○ Flexible Fuel Line-NPT ○ IBC Seismic Certification ○ Oil Temperature Indicator with Alarm
○ 12 Position Load Center ○ Remote E-Stop (Break Glass-Type, Surface Mount)
ELECTRICAL SYSTEM ○ Remote E-Stop (Red Mushroom-Type, Surface
○ 10A UL Battery Charger ENCLOSURE Mount)
○ Battery Warmer ○ Standard Enclosure ○ Remote E-Stop (Red Mushroom-Type, Flush Mount)

○ Level 1 Sound Attenuation ○ Remote Communication - Modem


ALTERNATOR SYSTEM ○ 10A Run Relay
○ Level 2 Sound Attenuation
○ Alternator Upsizing ○ Level 2 Sound Attenuation with Motorized Dampers ○ Ground Fault Indication and Protection Functions
○ Anti-Condensation Heater ○ Steel Enclosure
WARRANTY (Standby Gensets Only)
○ Aluminum Enclosure
CIRCUIT BREAKER OPTIONS ○ Up to 200 MPH Wind Load Rating* ○ 2 Year Extended Limited Warranty
○ Main Line Circuit Breaker ○ AC/DC Enclosure Lighting Kit ○ 5 Year Limited Warranty
○ 2nd Main Line Circuit Breaker ○ 5 Year Extended Limited Warranty
○ Shunt Trip and Auxiliary Contact ○ 7 Year Extended Limited Warranty
○ Electronic Trip Breakers ○ 10 Year Extended Limited Warranty

ENGINEERED OPTIONS

ENGINE SYSTEM GENERATOR SET TANKS


○ Fluid Containment Pan ○ Special Testing ○ Overfill Protection Valve
○ UL 2085 Tank
ALTERNATOR SYSTEM ENCLOSURE ○ ULC S-601 Tank
○ 3rd Breaker Systems ○ Enclosure Ambient Heaters ○ Stainless Steel Tank
○ Special Fuel Tanks (MIDEQ and FL DEP/DERM, etc)
CONTROL SYSTEM ○ Vent Extensions
○ Battery Disconnect Switch

SPEC SHEET

*Consult factory
3 of 6for availability 3 of 6
SB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

APPLICATION AND ENGINEERING DATA

ENGINE SPECIFICATIONS

General Cooling System

Make Perkins Cooling System Type Closed Recovery


EPA Emissions Compliance Stationary Emergency Water Pump Type Centrifugal Type, Belt-Driven
EPA Emissions Reference See Emission Data Sheet Fan Type Pusher
Cylinder # 6 Fan Speed (rpm) 1,439
Type In-Line Fan Diameter - mm (in) 965 (38)
Displacement - L (Cu In) 18.13 (1,106.36)
Bore - mm (in) 145 (5.71) Fuel System
Stroke - mm (in) 183 (7.20)
Fuel Type Ultra Low Sulfur Diesel #2
Compression Ratio 14.5:1
Carburetor ASTM
Intake Air Method Turbocharged/Aftercooled
Fuel Filtering (microns) Primary 10 - Secondary 2
Cylinder Head Type 4-Valve
Fuel Inject Pump Make Electronic
Piston Type Aluminum
Injector Type MEUI
Crankshaft Type I-Beam Section
Engine Type Pre-Combustion
Fuel Supply Line - mm (in.) 12.7 (0.5) NPT
Engine Governing
Fuel Return Line - mm (in.) 12.7 (0.5) NPT
Governor Electronic Isochronous Required Natural Gas Pressure - psi 1
Frequency Regulation (Steady State) ±0.25% Maximum Required Volume of Natural
45
Gas Needed - cfm
Lubrication System
Engine Electrical System
Oil Pump Type Gear
System Voltage 24 VDC
Oil Filter Type Full Flow
Battery Charger Alternator Standard
Crankcase Capacity - L (qts) 45 (47.55)
Battery Size See Battery Index 0161970SBY
Battery Voltage (2) - 12 VDC
Ground Polarity Negative

ALTERNATOR SPECIFICATIONS

Standard Model WEG Standard Excitation Permanent Magnet


Poles 4 Bearings Single Sealed Cartridge
Field Type Revolving Coupling Direct, Flexible Disc
Insulation Class - Rotor H Prototype Short Circuit Test Yes
Insulation Class - Stator H Voltage Regulator Type Full Digital
Total Harmonic Distortion <3% Number of Sensed Phases All
Telephone Interference Factor (TIF) <50 Regulation Accuracy (Steady State) ±25%
SPEC SHEET

4 of 6 4 of 6
SB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

OPERATING DATA

POWER RATINGS

Standby
Three-Phase 120/208 VAC @0.8pf 600 kW Amps: 2,081
Three-Phase 120/240 VAC @0.8pf 600 kW Amps: 1,804
Three-Phase 277/480 VAC @0.8pf 600 kW Amps: 903
Three-Phase 346/600 VAC @0.8pf 600 kW Amps: 723

STARTING CAPABILITIES (sKVA)


sKVA vs. Voltage Dip
480 VAC 208/240 VAC
Alternator kW 10% 15% 20% 25% 30% 35% Alternator kW 10% 15% 20% 25% 30% 35%
Standard 600 743 1,114 1,486 1,857 2,229 2,600 Standard 600 543 814 1,086 1,357 1,629 1,900
Upsize 2 832 757 1,136 1,514 1,893 2,271 2,650 Upsize 2 723 571 857 1,143 1,429 1,714 2,000

FUEL CONSUMPTION RATES*


Diesel Only – gal/hr (l/hr)**
Fuel Pump Lift - ft (m) Percent Load Standby
12 (3.7) 25% 18.4 (69.7)
50% 28.2 (88.7)
Total Fuel Pump Flow (Combustion + Return) gal/hr (l/hr) 75% 35.6 (124.8)
121 (457) 100% 41.4 (156.7)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
** Natural Gas substitution may vary based on the application and load conditions
Please consult factory for additional details on fuel consumption

COOLING
Standby
Coolant Flow per Minute gpm (lpm) 114.1 (432)
Coolant System Capacity gal (L) 13 (49)
Heat Rejection to Coolant BTU/hr 1,589,760
Inlet Air cfm (m3/min) 30,088 (852)
Maximum Operating Ambient Temperature °F (°C) 122 (50)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD
Maximum Radiator Backpressure in H2O 0.5

COMBUSTION AIR REQUIREMENTS


Standby
Flow at Rated Power cfm (m3/min) 1,836 (52)

ENGINE EXHAUST
Standby Standby
Rated Engine Speed rpm 1,800 Exhaust Flow (Rated Output) cfm (m3/min) 5,085 (144)
Horsepower at Rated kW** hp 909 Max. Total Backpressure (Post Turbo) inHg (Kpa) 2.13 (6.9)
Piston Speed ft/min 2,161.4 Exhaust Temp (Rated Output - Post Silencer) °F (°C) 1,155 (624)
SPEC SHEET

BMEP psi 361 Exhaust Outlet Size (Open Set) mm (in) Dual 152.4 (6)
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
† Calculated values

Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.
Standby - See Bulletin 0187500SSB
Prime - See 5Bulletin
of 6 0187510SSB 5 of 6
SB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Certified Stationary Emergency

DIMENSIONS AND WEIGHTS*

W OPEN SET (Includes Exhaust Flex)


Usable
Run Time
Capacity L x W x H (in (mm) Weight lbs (kg)
Hours
H Gal (L)
No Tank - 154.4 (3,923) x 71 (1,803) x 67 (1,702) 10,710 (4,868)
8 334 158.5 (4,026) x 71 (1,803) x 81 (2,057) 12,385 (5,628)
L 24 1,001 158.5 (4,026) x 71 (1,803) x 103 (2,616) 13,310 (6,047)
24 1,001 228 (5,791) x 71 (1,803) x 92 (2,337) 13,960 (6,297)
48 2,002 290 (7,366) x 71 (1,803) x 103 (2,616) 15,560 (7,098)
W
STANDARD ENCLOSURE
Usable Weight lbs (kg)
Run Time Enclosure Only
Capacity L x W x H (in (mm)
H
Hours
Gal (L) Steel Aluminum
No Tank - 207.4 (5,268) x 71 (1,803) x 80 (2,032)
8 334 207.4 (5,268) x 71 (1,803) x 94 (2,388)
1,999 869
L 24 1,001 207.4 (5,268) x 71 (1,803) x 116 (2,946)
(907) (394)
24 1,001 228 (5,791) x 71 (1,803) x 105 (2,667)
48 2,002 290 (7,366) x 71 (1,803) x 116 (2,946)

W LEVEL 1 ACOUSTIC ENCLOSURE


Usable Weight lbs (kg)
Run Time Enclosure Only
Capacity L x W x H (in (mm)
Hours
Gal (L) Steel Aluminum
H
No Tank - 247.5 (6,285) x 71 (1,803) x 80 (2,032)
8 334 247.5 (6,285) x 71 (1,803) x 94 (2,388)
2,782 1,291
24 1,001 247.5 (6,285) x 71 (1,803) x 116 (2,946)
(1,262) (586)
L 24 1,001 247.5 (6,285) x 71 (1,803) x 105 (2,667)
48 2,002 290 (7,366) x 71 (1,803) x 116 (2,946)
W
LEVEL 2 ACOUSTIC ENCLOSURE
Usable Weight lbs (kg)
Run Time Enclosure Only
Capacity L x W x H (in (mm)
Hours
Gal (L) Steel Aluminum
H
No Tank - 207.4 (5,268) x 71 (1,803) x 114 (2,899)
8 334 207.4 (5,268) x 71 (1,803) x 128 (3,251)
3,330 1,522
24 1,001 207.4 (5,268) x 71 (1,803) x 150 (3,810)
(1,510) (692)
24 1,001 228 (5,791) x 71 (1,803) x 139 (3,531)
L 48 2,002 290 (7,366) x 71 (1,803) x 150 (3,810)

* All measurements are approximate and for estimation purposes only.

YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER


SPEC SHEET

Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.
6 of 6 6 of 6

Generac Power Systems, Inc. | P.O.Box 8 | Waukesha, WI 53189 Part No 0K4728


P: (262) 544-4811 ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Rev. E 08/08/17