Sie sind auf Seite 1von 2

CO−31

COOLING − COOLING FAN RELAY

No. 1 Cooling COOLING FAN RELAY


Fan relay CO054−03

INSPECTION
1. INSPECT NO. 1 COOLING FAN RELAY
(a) Remove the relay box cover.
(b) Remove the No. 1 cooling fan relay. (Marking: FAN No. 1)

B08783

Continuity (c) Inspect the No. 1 cooling fan relay continuity.


(1) Using an ohmmeter, check that there is continuity
Ohmmeter 2 Ohmmeter
1 between terminals 1 and 2.
5
If there is no continuity, replace the relay.
(2) Check that there is no continuity between terminals
3 and 5.
3 If there is continuity, replace the relay.

No Continuity
S04970

(d) Inspect the No. 1 cooling fan relay operation.


2
(1) Apply battery positive voltage across terminals 1
Ohmmeter
1 and 2.
5 (2) Using an ohmmeter, check that there is continuity
between terminals 3 and 5.
If there is no continuity, replace the relay.
3 (e) Reinstall the No. 3 cooling fan relay.
Battery (f) Reinstall the relay box cover.
Continuity
S04969

No. 2 Cooling
2. w/ A/C:
Fan Relay INSPECT NO. 2 COOLING FAN RELAY
(a) Remove the relay box cover.
(b) Remove the No. 2 cooling fan relay. (Marking: FAN No. 2)

B08784

Ohmmeter Continuity (c) Inspect the No. 2 cooling fan relay continuity.
4 (1) Using an ohmmeter, check that there is continuity
2 Ohmmeter between terminals 1 and 2.
1 If there is no continuity, replace the relay.
5
(2) Check that there is continuity between terminals 3
Ohmmeter
and 4.
If there is no continuity, replace the relay.
3
(3) Check that there is no continuity between terminals
Continuity No ContinuityS04972 3 and 5.
If there is continuity, replace the relay.
1ZZ−FE, 2ZZ−GE ENGINE (RM733E)
CO−32
COOLING − COOLING FAN RELAY

(d) Inspect the No. 2 cooling fan relay operation.


4 (1) Apply battery positive voltage across terminals 1
2 Ohmmeter and 2.
5 (2) Using an ohmmeter, check that there is no continu-
Battery 1
Ohmmeter ity between terminals 3 and 4.
If there is continuity, replace the relay.
(3) Check that there is continuity between terminals 3
3
and 5.
Continuity
No Continuity S04971 If there is no continuity, replace the relay.
(e) Reinstall the No. 2 cooling fan relay.
(f) Reinstall the relay box cover.

No. 3 Cooling 3. w/ A/C:


Fan relay INSPECT NO. 3 COOLING FAN RELAY
(a) Remove the relay box cover.
(b) Remove the No. 3 cooling fan relay. (Marking: FAN No. 3)

B08785

Continuity (c) Inspect the No. 3 cooling fan relay continuity.


(1) Using an ohmmeter, check that there is continuity
Ohmmeter 2 Ohmmeter
1 between terminals 1 and 2.
5
If there is no continuity, replace the relay.
(2) Check that there is no continuity between terminals
3 and 5.
3 If there is continuity, replace the relay.

No Continuity
S04970

(d) Inspect the No. 3 cooling fan relay operation.


2
(1) Apply battery positive voltage across terminals 1
Ohmmeter
1 and 2.
5 (2) Using an ohmmeter, check that there is continuity
between terminals 3 and 5.
If there is no continuity, replace the relay.
3 (e) Reinstall the No. 3 cooling fan relay.
Battery (f) Reinstall the relay box cover.
Continuity
S04969

1ZZ−FE, 2ZZ−GE ENGINE (RM733E)