Sie sind auf Seite 1von 1

DS

A B C D E A B C D E
2550 2950 2020 2330 2550 2950 2020 2330 R
T
VS
TO STREET
0 SEWER 60
1 216 1 21 DS

CO

2422

2422
CB
WC WC
31 13
1
31 3 FD
LAV LAV
DS
V
2 2 LA
WC V CO V
LA

UP

UP
LA
CB ET CB
WCFD
RE

SP
88 88
35 35 STRAIN 10
Ø TO D 0

75 Ø
5 Ø
K 2 25 SP
CO KS Ø
KSK SK SP

4788

4788
KSK K Ø
00
UP UP

3 02
3 02
CB
G
E TIN CB 1 G
E TIN

SP
31 31 TUREXIS CO 10 T UREXIS
FD
C F C F
RU O O 0Ø RU O

75 Ø
KSK ST ION SH ST ION
SP TR
KSK
SK
T T
VS
DS
R R
388

388
K PO PO
K
KS
U
CB FD FA CB
4 4 V
LA

PORTION OF EXISTING

PORTION OF EXISTING
V
WC S FD LA

16322

16322
W C

STRUCTURE

STRUCTURE
25 S
Ø CB
D FD CO S
CO
3112

3112
SP
CV 0 0Ø CB

M GV 1
SP

5112

5112
E Ø
VIC CO 75
S ER TION DS SP
5 5 R C
TE NNE 0Ø CB
WA CO 10
FD
SP
Ø
75

FD
SHO FD NK
FAU TA
PTIC CB
ET

2000

2000
6000

6000
SE
6 WC 6 WC
FD
RE
STRAIN
LAV FD FD CO LAV TO D
CO
ET
SEPTIC TANK RE
ST WER
SINK 2000 S TO SE

2000
CO
CB CB CB
DS DS DS
7 7
2500 5500 2700 1650 M
CV
2500 5500 2700 1650
3 WATER LINE ISOMETRIC 4 SANITARY & DRAINAGE LINE ISOMETRIC
GV
12350 12350
WATER SERVICE TO STREET
CONNECTION SEWER 500 500
400 400
500

1 WATER LINE LAYOUT 2 SANITARY & DRAINAGE LINE LAYOUT 400 STEEL COVER STEEL COVER

75 mm Ø
DRAIN PIPE 75 mm Ø 75 mm Ø
DRAIN PIPE DRAIN PIPE
4" THK. CHB
4" THK. CHB 4" THK. CHB

400
500
1/2" Ø GRAVEL

STEEL COVER 12mm Ø DEF. BARS 12mm Ø DEF. BARS

LEGEND: PLUMBING NOTES: PVC CLEANOUT PLUG

FIN. WALL LINE


1/2" Ø GRAVEL

WATER LINE 1. Grade of all horizontal piping runs all horizontal in perfect alignment PVC 1/8 BEND PLAN CROSS SECTION LONGITUDINAL SECTION
at from grade of not less than 2%. PVC WYE FITTING
SANITARY LINE
2. Change in Direction: All change in direction shall be made of 5 CATCH BASIN DETAIL
DRAINAGE LINE approximate use of 45 degrees Wyes, Long Sweep
Quarter Bend, 6/8 or Sixteenth Bends.
GV GATE VALVE When change of flow is from horizontal or vertical, a single 1/8 Bend
0.40m x 0.40m
combination maybe used on Vertical Stack, and MANHOLE COVER
M METER short Quarter Bends maybe used in Vent Pipes.
6" Ø INLET 12mm Ø BARS SPACED
CV CHECK VALVE 3. Prohibited Fittin No Double Hub or Tee Branch shall be used on AT WALL PIPE @ 0.15m BOTHWAYS
Horizontal Soil or Waste Line, the drillings and

300
AIR SPACE
S SINK tapping of house drain, Waste or Vent Pipes, and use of Saddle Hub
and Bends are prohibited. WATER LEVEL
LAV LAVATORY
FIN. LINE GRADE 0.10m Ø 0.10m Ø
4. Pipe Clean-Outs Clean-Outs are required under the following OUTLET PIPE OUTLET PIPE
KSK KITCHEN SINK conditions: POURED CONCRETE PAD TO STREET TO STREET

1300
SEWER SEWER
a. Every change in horizontal direction exceeding 22 1/2 degrees. PVC CLEANOUT PLUG
WC WATER CLOSET b. 1.5 meters inside the property line before the House Drain

1500
PVC 1/8 BEND
connection. 0.40m x 0.40m 10m Ø BAR
MANHOLE DIGESTIVE CHAMBER LEACHING CHAMBER
FAU FAUCET c. Every 15 meters of direction run of pipes. COVER
SPACED @
DIGESTIVE CHAMBER LEACHING CHAMBER .60m
d. At the end of any horizontal pipelines. VERTICAL &
SHO SHOWER HORIZONTAL
5. The Digestion Chamber of Septic Vault must be waterproofed.
CB CATCH BASIN 1700 1000
6. Not less than 0.30m air space must be left between the top of
FD FLOOR DRAIN 3000
Sewage, and the under part of the vault roof slab.
AT GRADE
DS DOWNSPOUT 7. No Septic Vault shall be constructed inside the building. 10mm Ø BAR SPACED @
PLAN AS SHOWN BOTHWAYS
SP SOIL PIPE 8. All Plumbing Works shall be done by a Licensed Master Plumber, 6 CLEAN OUT DETAIL
or a Licensed Plumbing Contractor. CROSS SECTION
VSTR VENT STACK THRU ROOF 7 SEPTIC TANK DETAIL

P-1

Das könnte Ihnen auch gefallen