COMPANY INTRODUCTION
Zhejiang Eastron Electronic Co., Ltd. (Eastron) , a leading high-tech manufacturer and supplier of energy metering Persuing the excellence of quality
products and energy management solutions in China.

Quality is highly valued, Eastron strictly follows ISO9001:2015 in operation, management. Eastron has obtained the

勇攀科技高峰
MID (Measuring Instruments Directive) D from SGS for its production site. Eastron products had passed the European
MID B, CE, ROHS 2.0 authentication and complied with relevant IEC, EN, and G/B standard. With high quality products and
reliable services, Eastron has gained a good reputation among clients and partners in more than 50 countries.

As one of the most reliable suppliers of meters in China for high quality, competitive price and excellent after-sales
services, Eastron provides not only the existing products and services, we can also design and provide the products and s
ervices requested by customer. We are so proud of being favored by customers for our meters and solutions, especially Climbing the peak of Technology
for din rail energy meters, Panel power meters, Current transformers, relay and timers, Gateway and Management
Systems etc.

To meet the challenges of ever changing industry development, product design and manufacturing processes are
constantly being improved, which makes Eastron keep its competitive edge in the market. With more than 30 patented
technologies, Eastron has been awarded with the certificate of “National High-tech enterprise”.
PROFESSIONAL MANUFACTURER OF METERS

Our Mission
"Create Value to and Grow Up with Our Partners". We strive to help our customer gain commercial advantage by c
onsistently providing competitively-priced, high-quality products together with the best possible technical support.
Moreover, we pride ourselves on focusing not only our customer's short-terms requirements but also on the long-
terms needs of the marketplace.
This drives us to give the best customer service in the industry and ensure completing customer satisfaction.

We warmly welcome YOU contacting with us.


MID DIN-RAIL METER
SMART

What’s MID?
Conditions of application
The Measuring Instruments Directive (2014/32/EU) is a directive by the European Union, which seeks to harmonise many aspects of legal metrology across all
member states of the EU. Its most prominent tenet is that all kinds of meters which receive a MID approval may be used in all countries across the EU. In the European Union, the use of MID-certificated meters on “Private” electrical networks has been mandatory in the context of active energy billing based
on consumption reading by index differences. Typical examples include; camping sites ,holiday rentals, students accommodation, office building, shopping
centers, marinas, exhibition halls, electric vehicle recharging station, etc.

Which measuring instruments MID covers? As the MID is applicable to all European Union Member States, certification of ammeter by a Notified Body(NB) means that no other testing by a national legal
metrological service is required. So a MID certificated Eastron meter can be used as an active energy billing meter in all European Union countries.
The MID covers these measuring instruments: The Directive also imposes product certification according to the EN50470-1/-3 standards, as well as design certification (Module B) and manufacturing process
gas meters certification(Module D) by a Notified Body. In order to ensure product traceability and guarantee its metrological value, thus to protect consumers.
meters for liquids other than water
meters for liquids other than water - ancillary equipment
material measures of length
continuous totalising weighing machines
Certificates MID B +D we have:
electrical energy meters
Taximeters
measuring systems for liquids other than water Directive
automatic checkweighing and weight grading machines
hot-water meters Partial repeal
cold-water meters, as concerns clean water meters

Measuring instruments that comply with the MID bear:


The measuring instruments that comply with the MID bear the marks:
the CE mark
a capital letter "M" and the last two digits of the year of its affixing, surrounded by a rectangle
the identification number of the notified body involved in conformity assessment

Which products of us are MID approved by SGS.


7 xxxx Input:230V AC 50Hz
Till present, Eastron has the MID approved models
0,25~5(45)A cover these items:
Year:2017

Year of manufacture No. of Notified Body

Regulatory Context
The Measuring Instruments Directive was published on 30 April 2004 in the Official Journal of the EU, 1 2 3 7
but not applied until after 30 Oct 2006 and there is a 10-year transition period. National implementations
of the new legislation are currently in the works. The MID directive is updated by 2014/32/EU. 4 5 6
1. SDM120 Series SGS0141
2. SDM220 Series SGS0172
Directive transposed into national law of each country in 2006 3. SDM230 Series SGS0206
European directive on measuring
instruments dated 31st March 2004 4. SDM630MCT series SGS0142
2 specific European standards (EN 50470-1/EN 50470-3) for energy 5. SDM630 100A series SGS0151
meters, stipulating the particular requirements and type tests for energy meters
6.SDM72 Series SGS0213
7.Smart X96 Series SGS0288

MID becomes the ONLY accepted


European Legislation from 2016!

1 Product Catalog EASTRON Product Catalog EASTRON 2


Energy
SMART Monitoring
DIN-RAIL Solution
METER

Energy Meter for Solar PV and Charging station

Eastron Energy Ethernet WAN WAN

Management System Router Internet Eastroncloud

RS 485

SDM series Inverter


Input

ROUTER
Ethernet SERVER

Grid load Solar energy

WIFI GPRS GPRS

SDM series Charging Station Car

ESP-4
SMART X96-I SMART X96-J ESP-6 ESP-5

X203

LORA

Rs485

SMART X
Rs485
Rs485 Rs485
Solar PV Array Monitoring Solution
ESP-2

SDM120M

ESP-7 1Ph Lora meter


SDM230M
Monitoring software Gateway

SDM630M
SMART X
Rs485

M-Bus

ESP-7 3Ph Lora meter


ESP-2
Router
Gateway

SDM120MB SDM230MB SDM630MB SDM530MB

Convertor

3 Product Catalog EASTRON Product Catalog EASTRON 4


Plug-in
SMART Play Solution METER
DIN-RAIL

“Plug-in Play Solution”


Current connection cable between Current connection cable between
the CT and the meter. 5A CT and the meter.
Cable Length up to 5M. ESCT-SC ESCT-SC

SECT-RJ SECT-RJ

Current connection cable between


100mA/333mV CT and the meter.
ESCT-SC
SECT-RJ SECT-SC
32
meters Rj12 socket for
fast connection and to
eliminate wiring errors

SMART X96-5 Smart X96-5


SMART X96
SMART X96-1
L1
L2
L3
N

The example shows a wiring in 3p4w network.


Plug-in terminals for voltage inputs.
L1
L2
Self power supply from L1.
L3
N Daisy chain connection for power supply.
The example shows a wiring in 3p4w network. Max. 32pcs meters can be connected.
the meter can also work in 3p3w and 1p2w system. Plug-in type voltage terminals.

Plug-in Play Solution

ESCT-RJ Series ESCT-SC Series PSC Series Rj12 Cable


ALL YOU NEED TO DO RJ 12 socket Screw terminals PSC-VSC: Rj12 cable for the connection
3-IN-1 combined 3-IN-1 combined Voltage supply cable between the Current Transformer
60~630A Primary 100~630A Primary PSC-V2V: ESCT-RJ and the power meters
IS JUST “PLUG-IN” 100mA/333mV output
Busbar, Din Rail base
1A/5A output
Busbar, Din Rail base
Voltage daisy chain cable
PSC-M2C:
with RJ12 terminal.

Class 0.5s Class 0.5s Meter to CT cable

SMART X96 SERIES SMARTCONNECT X835 SMART X96 SERIES SDM630MCT-RJ SDM630MCT-2L
MID B+D DIN 96 panel mounted DIN 96 panel mounted Din rail mounted Din rail mounted
333mV/ 5A input Class 0.5S/0.2S accuracy 333mV/ 100mA input 2 three phase circuit measured
1ph/3ph network compatiable Rs485 Modbus/ Ethernet TCP True RMS measurement 333mV/ 100mA input
True RMS measurement Multi-Tariffs and RTC Rs485 MODBUS True RMS measurement
Measures 85 Important Electrical Parameters Multi-Tariff and RTC Rs485 MODBUS Alarm and SOE 2 Pulse outputs Rs485 MODBUS
2nd~63rd THD & IHD for Volatege and Current THD-i & THD-u Digital Input and outputs THD-i & THD-u 2 Pulse outputs
Alarms and SOE 2~63rd IHD-u and IHD-i
CT & PT programmable Multi-parameters measured THD-i & THD-u
Bar Graph for Power Indication Accuracy Class 0.5S/0.2S CT & PT programmable Multi-parameters measured
Multi-parameters measured
RS485 Modbus RTU Full Viewing Angles LCD Display 1p2w,3p3w,3p4w network
Ethernet Modbus TCP (as Gateway) Energy Information of Each Phase
Digital Inputs and Digital Outputs

5 Product Catalog EASTRON Product Catalog EASTRON 6


Multi
SMART ClickDIN-RAIL
Solution METER

Simple Wiring and Cost Reduce


“Multi Click Solution”
Flexible Multi Circuits Monitoring

MCS-D40

Ethernet

MCS -Dxx Display


Management software

Voltage inputs to MCS-U or MCS-C Connection between ESCT-RJ and MCS-I Connection between MCS-I and MCS-U/C

Gateway
MCS-I31

MCS-U20 Multi Circuit Monitoring Solution


COMM COMM
COMM COMM COMM COMM COMM

M C S-I31
COMM COMM

M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
ALARM

M C S-I31

M C S-I31
ALARM ALARM ALARM ALARM ALARM
ALARM ALARM ALARM
ON ALARM COMM ON ON ON
ON ON ON ON
ON ON

CMS-C40

ESCT-RJ Series ESCT-SC Series Rj45 Cable Rj12 Cable


ESCT-RJ3 RJ 12 socket RJ 12 socket Rj45 cable for the connection Rj12 cable for the connection
Rs485 Modbus

Split Core 3-IN-1 combined between the CMS-I and CMS-U; between the Current Transformer
10~600A Primary 60~630A Primary CMS-U and CMS-D module. ESCT-RJ and the power meters
100mA/333mV output 100mA/333mV output with RJ12 terminal.

MCS -I31 X 32 Class 0.5s Busbar, Din Rail base


Class 0.5s

MCS-U20
Smaller Size
Cheaper Cost
COMM COMM
COMM COMM COMM COMM COMM
M C S-I31

COMM COMM
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31

ALARM
M C S-I31

M C S-I31

ALARM ALARM ALARM ALARM ALARM


ALARM ALARM ALARM
ON ALARM COMM
ON ON ON ON ON ON ON ON ON
MCS-D40

TX+ TX-
Rs485
MCS-U20

MCS-U20 MCS-U20

Smarter Function COMM

MCS-I31
ALARM

ON
ON ALARM COMM ON ALARM COMM

ESCT-RJ1
Faster Connection MCS-I3x Series MCS-Uxx Series MCS-Cxx Series MCS-Dxx Series
Current module Voltage module Communication module Display Module
ESCT-RJ1 DIN rail mounted DIN rail mounted DIN rail mounted Panel mounted
333mV input 3x230(400)V inputs 3x230(400)V inputs LCD display
1ph/3ph network compatible 1ph/3ph network compatible 1ph/3ph network compatible Graph and Curves
True RMS measurement Voltage, Frequency,THD-u Voltage, Frequency,THD-u Rs485 Modbus RTU
Current, Power, THD-i Over-voltage alarm Over-voltage alarm Ethernet TCP
CT ratio programmable Class 0.5s Class 0.5s 256M memory
Overcurrent alarm Rs485 Modbus RTU
Class 0.5s

7 Product Catalog EASTRON Product Catalog EASTRON 8


OVERDIN-RAIL
SMART VIEW METER

SDM120 SERIES Single Phase SDM72 SERIES Three Phase

Model Specifications Description Size Model Specifications Description Size

SDM 120A MID 230V,0.25~5(45)A,50/60Hz Energy(kWh), Pulse output 1 Module 3X230(400)V,0.5~10(100)A,50/60Hz


SDM72D MID Energy(kWh), Pulse output 4 Modules
3X127(230)V,0.5~10(100)A,50/60Hz
SDM 120D/DB MID 230V / 110V ,0.25~5(45)A,50/60Hz Energy(kWh), Pulse output 1 Module
SDM72DR MID 3X230(400)V,0.5~10(100)A,50/60Hz Energy(kWh) and Power(KW),Energy Resettable, Pulse output 4 Modules
SDM 120P MID 230V / 110V ,0.25~5(45)A,50/60Hz Multifunction, Pulse outputs 1 Module
SDM72BI MID 3X230(400)V,0.5~10(100)A,50/60Hz Import / Export kWh,Power,Energy Resettable,Pulse outputs 4 Modules
SDM 120Modbus MID 230V / 110V ,0.25~5(45)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 1 Module
SDM72DM MID 3X230(400)V,0.5~10(100)A,50/60Hz Import / Export kWh,Power,RS485 Modbus, Pulse outputs 4 Modules
SDM 120Mbus MID 230V / 110V ,0.25~5(45)A,50/60Hz Multifunction, Mbus,Pulse outputs 1 Module

SDM 120CTP MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, Pulse outputs 1 Module

SDM 120CT-Modbus MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, RS485 Modbus,Pulse outputs 1 Module

SDM 120CT-Mbus MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, Mbus,Pulse outputs 1 Module SDM72 CT SERIES Three Phase

Model Specifications Description Size


SDM220 SERIES Single Phase SDM72CT-D 3X230/400V,0.25~5(6)A,50/60Hz Energy(kWh), Pulse output 4 Modules

SDM72CT-DR 3X230/400V,0.25~5(6)A,50/60Hz Energy(kWh) and Power(W),Energy Resettable, Pulse output 4 Modules

Model Specifications Description Size SDM72CT-BI 3X230/400V,0.25~5(6)A,50/60Hz Import / Export kWh,Power(W),Energy Resettable,Pulse outputs 4 Modules

SDM220Modbus MID 230V/110V,0.25~5(100)A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 2 Modules SDM72CTM 3X230/400V,0.25~5(6)A,50/60Hz Import / Export kWh,Power,RS485 Modbus, Pulse outputs 4 Modules

SDM220Mbus MID 230V,0.25~5(100)A,50/60Hz Multifunction, Mbus, Pulse outputs 2 Modules

SDM220MT MID 230V,0.25~5(100)A,50/60Hz 4 tariffs, Multifunction, RS485 Modbus, Pulse outputs 2 Modules

SDM220Pulse MID 230V/110V,0.25~5(100)A,50/60Hz Multifunction, Pulse outputs 2 Modules SDM630 100A SERIES Three Phase

SDM220Standard MID 230V,0.25~5(100)A,50/60Hz Import/ Export kWh, RS485 Modbus, Pulse outputs 2 Modules
Model Specifications Description Size
SDM630Pulse MID 3X230/400V,0.5~10(100)A,50/60Hz Multifunction, Pulse outputs 4 Modules
SDM230 SERIES Single Phase SDM630Standard MID 3X230/400V,0.5~10(100)A,50/60Hz Import /Export kWh, RS485 Modbus,Pulse outputs 4 Modules

SDM630Modbus MID 3X230/400V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 4 Modules

Model Specifications Description Size SDM630Mbus MID 3X230/400V,0.5~10(100)A,50/60Hz Multifunction, Mbus,Pulse outputs 4 Modules

SDM230A 230V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 2 Modules SDM630MT MID 3X230/400V,0.5~10(100)A,50/60Hz Multi-tariffs (RTC), Multifunction, RS485 Modbus 4 Modules

SDM230D 230V/110V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 2 Modules SDM630-2T 3X230/400V,0.5~10(100)A,50/60Hz 2tariffs(Time-relay), Multifunction, RS485 Modbus 4 Modules

SDM230DR MID 230V,0.5~10(100)A,50/60Hz Energy(kWh) and Power(W),Energy Resettable, Pulse output 2 Modules

SDM230Bi MID 230V,0.5~10(100)A, 50/60Hz Import /Export kWh,Power(W),Energy Resettable,Pulse outputs 2 Modules
SDM230Modbus MID 230V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 2 Modules SDM630 MCT SERIES Three Phase
SDM230Mbus MID 230V,0.5~10(100)A,50/60Hz Multifunction, Mbus,Pulse outputs 2 Modules
SDM230Pulse MID 230V,0.5~10(100)A,50/60Hz Multifunction, Pulse outputs 2 Modules Model Specifications Description Size
SDM230Standard MID 230V,0.5~10(100)A,50/60Hz Import / Export kWh, RS485 Modbus,Pulse outputs 2 Modules SDM630MCT MID 3X230/400V,1A or 5A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 4 Modules
SDM230-2T MID 230V,0.5~10(100), 50/60Hz 2 tariffs, Multifunction, RS485 Modbus,Pulse output 2 Modules SDM630MCT-Mbus MID 3X230/400V,1A or 5A,50/60Hz Multifunction, Mbus, Pulse outputs 4 Modules
SDM230-LoRa 230V,0.5~10(100), 50/60Hz Multifunction, LoRa Communication,Pulse output 2 Modules SDM630MCT-2T MID 3X230/400V,1A or 5A,50/60Hz 2 Tariffs, Multifunction , Mbus, Pulse outputs 4 Modules

SDM630MCT-MV 3X230/400V, 333mV CT,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 4 Modules

SDM630MCT-RJ 3X230(400)V,100mA or 333mV CT,50/60Hz Plug-in Solution ,Multifunction, RS485 Modbus , Pulse outputs 4 Modules
SDM320 SERIES Single Phase SDM630MCT-2L 3X230(400)V,100mA or 333mV CT,50/60Hz Dual-load, Multifunction, RS485 Modbus 4 Modules

SDM630MCT-LoRa 3X230(400)V,100mA or 333mV CT,50/60Hz Multifunction, LoRa Communication, Pulse outputs 4 Modules
Model Specifications Description Size
SDM320D 230V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 4 Modules

SDM320E 110/220V,0.5~10(100)A,50/60Hz Energy(kWh) , Pulse output 4 Modules SDM630 2C SERIES Three Phase
SDM320M 230V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 4 Modules

SDM320EM 110/220V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 4 Modules Model Specifications Description Size
SDM630 CT-2C 3X230(400)V,1A or 5A,50/60Hz Dual load Multifunction, RS485 Modbus,Pulse outputs 6 Modules

SDM630MV-2C 3X230(400)V,333mV CT ,50/60Hz Dual load Multifunction, RS485 Modbus,Pulse outputs 6 Modules

9 Product Catalog EASTRON Product Catalog EASTRON 10


OVERDIN-RAIL
SMART VIEW METER

SDM530 SERIES Three Phase SMART X203 SERIES Single Phase

Model Specifications Description Size Model Specifications Descriptions Accuracy


SDM530D 3X230(400)V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 7 Modules Smart X203 B 3x230(400)V AC, 5A CT, 50/60Hz Multifunction, RS485 Modbus, Pulse outputs, Class 1.0 / 0.5s
SDM530D-2T 3X230(400)V,0.5~10(100)A,50/60Hz 2 tariffs,Energy(kWh), Pulse output 7 Modules Smart X203 DIO 3x230(400)V AC, 5A CT, 50/60Hz Multifunction, RS485 Modbus, Digital Inputs, Digital Output Class 1.0 / 0.5s
SDM530-Modbus 3X230(400)V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 7 Modules
SDM530-DO 3X230(400)V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs, Digital Output 7 Modules
SDM530-Mbus 3X230(400)V,0.5~10(100)A,50/60Hz Multifunction, Mbus, Pulse outputs 7 Modules SMART X72 SERIES Three Phase
SDM530-MT 3X230(400)V,0.5~10(100)A,50/60Hz 4 tariffs, Multifunction, RS485 Modbus , Pulse outputs 7 Modules
SDM530CT-Modbus 3X230(400)V,5A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 7 Modules
Model Specifications Descriptions Accuracy
SDM530CT-Mbus 3X230(400)V,5A,50/60Hz Multifunction, Mbus, Pulse outputs 7 Modules
Smart X72 3x230(400)V AC, 5A CT, 50/60Hz Multifunction, RS485 Modbus, Pulse outputs, 31st THD Class 1.0 / 0.5s
SDM530CT-MT 3X230(400)V,5A,50/60Hz 4 tariffs ,Multifunction, RS485 Modbus, Pulse outputs 7 Modules
Smart X72 MV 3x230(400)V AC, 333mV CT, 50/60Hz Multifunction, RS485 Modbus, Pulse outputs, 31st THD Class 1.0 / 0.5s

Smart Connect X72 A 1A /5A CT , 50/60Hz 3 Phase current; RS 485 Modbus Class 0.5s/0.2s

Smart Connect X72 V 3x230(400)V , 50/60Hz 3 PhaseVoltage; RS 485 Modbus Class 0.5s/0.2s
Prepay Energy Meter
Smart Connect X72 W 3x230(400)V AC, 5A CT, 50/60Hz 3 Phase current ,Voltage and Power; RS 485 Modbus Class 0.5s/0.2s

Model Specifications Description Size


SDM320Y 230, 0.5~10(80)A, 50/60Hz Energy(kWh), Pulse output, RS 485 4 Modules
SDM530Y Energy(kWh), Pulse output, RS 485 7 Modules
SMART Connect X835 SERIES Three Phase
3X230(400)V, 3x0.5~10(80)A, 50/60Hz

Model Specifications Descriptions Accuracy


Smart Connect X835 CT 3x230(400)V AC, 5A CT, 50/60Hz Multifunction, RS485 Modbus, Pulse outputs, 31st THD Class 1.0 / 0.5s
Multi Circuit Monotring Solution Smart Connect X835 MV 3x230(400)V AC, 333mV CT, 50/60Hz Multifunction, RS485 Modbus, Pulse outputs, 31st THD Class 1.0 / 0.5s

Smart Connect X835 A 1A /5A CT , 50/60Hz 3 Phase current; RS 485 Modbus Class 0.5s/0.2s
Model Specifications Description Smart Connect X835 V Class 0.5s/0.2s
3x230(400)V , 50/60Hz 3 PhaseVoltage; RS 485 Modbus
MCS-I30 3x CT operated RJ12 input Current , power, energy
Smart Connect X835 W 3x230(400)V AC, 5A CT, 50/60Hz 3 Phase current ,Voltage and Power; RS 485 Modbus Class 0.5s/0.2s
M C S-U20

COMM COMM COMM COMM COMM COMM COMM


MCS-I31 3x CT operated RJ12 input Current , power, energy, THD-i
MCS -I31

COMM COMM
MCS -I31
MCS -I31
MCS -I31
MCS -I31
MCS -I31
MCS -I31

ALARM
MCS -I31

MCS -I31

ALARM ALARM ALARM ALARM ALARM


ALARM ALARM ALARM
ON ALARM COMM ON ON ON
ON ON ON ON
ON ON

MCS-I32 3x CT operated RJ12 input Current , power, energy, THD-i, Overcurrent

SMART X835 SERIES Three Phase


MCS-U20 3x230/400V; 3x127/220V Voltage , Frequency
Model Specifications Descriptions Accuracy
MCS-U21 3x230/400V; 3x127/220V Voltage , Frequency, THD-u
MCS-D40

3x230/400V, 1A /5A , 50/60Hz Multi-parameters; CT & PT programmable;


MCS-U22 3x230/400V; 3x127/220V Voltage , Frequency, THD-u, Overvoltage Smart X835B Class 1.0 / 0.5s
3P4W, 3P3W,1P2W RS 485 Modbus; 2 Pulse outputs; 2~31stTHD; Aux. power supply
3x230/400V, 1A /5A , 50/60Hz Multi-parameters; CT & PT programmable;
Smart X835-AO Class 1.0 / 0.5s
3P4W, 3P3W,1P2W RS 485 Modbus; 2 Analog outputs; 2~31stTHD; Aux. power supply
MCS-C20 230V ac. / 24V dc. Aux. supply Voltage , Frequency, Rs485 Modbus RTU
3x230/400V, 1A /5A , 50/60Hz Multi-parameters; CT & PT programmable; Aux. power supply;
MCS-C21 230V ac. / 24V dc. Aux. supply Voltage , Frequency, THD-u, Rs485 Modbus RTU Smart X835 DIO RS 485 Modbus; 2 Digital Inputs; 2 Digital outputs ; 2~31stTHD Class 1.0 / 0.5s
3P4W, 3P3W,1P2W
MCS-C22 230V ac. / 24V dc. Aux. supply Voltage , Frequency, THD-u, Overvoltage, Rs485 Modbus RTU

MCS-D40 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; SMART X96 SERIES Three Phase

MCS-D50 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; Ethernet
MCS-D60 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; Ethernet; 256Mhz Memory Model Specifications Descriptions Accuracy
3x230/400V, 100mA , 50Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-1 MID
RS 485 Modbus; 2 Pulse outputs; 2~63rdTHD; self-power supply; Class 1.0 / 0.5s
3P4W, 3P3W, 2P3W, 1P2W
3x230/400V, 1A /5A , 50Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-5A MID
3P4W, 3P3W, 2P3W, 1P2W RS 485 Modbus; 2 Pulse outputs; 2~63rdTHD; self-power supply; Class 1.0 / 0.5s
ESP-7 SERIES Converter
3x230/400V, 1A /5A , 50/60Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-5F RS 485 Modbus; 2~63rdTHD; Aux. power supply; Class 1.0 / 0.5s / 0.2s
3P4W, 3P3W, 2P3W, 1P2W

Model Input Output Power supply Smart X96-5G Same as Model“ F” Model“ F ”+ 4 Digital Inputs and 2 Digital outputs Class 1.0 / 0.5s / 0.2s

ESP-7100 RS 485; 1200~38400bps LoRa 470/433Mhz 9~24V DC, 2W Smart X96-5H Same as Model“ F” Model“ F ”+ Ethernet port Class 1.0 / 0.5s / 0.2s
ESP-7110 RS 485 ; 1200~38400bps Ethernet TCP 9~24V DC, 2W Smart X96-5I Same as Model“ F” Model“ F ”+ Ethernet port + 4 digital inputs and 2 Digital outputs Class 1.0 / 0.5s / 0.2s
ESP-7120 RS 485 ; 1200~38400bps Wifi IEEE802.11b/g/n 9~24V DC, 2W Model“ F ”+ Ethernet Gateway (RTU toTCP)
Smart X96-5J Same as Model“ F” Class 1.0 / 0.5s / 0.2s
+ 4 digital inputs and 2 Digital outputs

Smart X96-Lora Same as Model“ F” Model“ F ”+ Lora Communication Class 1.0 / 0.5s / 0.2s

11 Product Catalog EASTRON Product Catalog EASTRON 12


OVERDIN-RAIL
SMART VIEW METER

Pm1000 SERIES Single Phase ESAC PM200 SERIES Moving lron Movement

Model Specifications Accuracy Size Model Measurement Range Accuracy Size


PM1000-A 0~9999A (1A/5A CT input) 0.5% 48x96, 72x72, 96x96 PM200-AD mA : 50 100 150 200 400 500 600 800 ; A : 1 5 10 15 20 25 30 40 50 60 100 1.5 72x72, 96x96
PM1000-V 0~600V AC 0.5% 48x96, 72x72, 96x96 PM200-AC X /1A ( X: 10~3000A ) ; X/5A (X: 10~3000A) 1.5 72x72, 96x96
PM1000-Hz 45~66Hz 0.02Hz 48x96, 72x72, 96x96 PM200-VD V : 10 25 40 60 100 150 250 300 450 500 600 1.5 72x72, 96x96
PM1000-W 0~600V AC; 1A/5A CT input 0.5% 48x96, 72x72, 96x96 PM200-VP External PT Operated X/100V X/110V X/120V 1.5 72x72, 96x96
PM1000-PF 0~600V AC; 1A/5A CT input 0.01 48x96, 72x72, 96x96

ESAC PM300 SERIES Moving Coil Movement


Pm1500 SERIES Single Phase

Model Measurement Range Accuracy Size


Model Specifications Accuracy Size PM300-AD mA : 50 100 150 200 400 500 600 800 ; A : 1 5 10 15 20 25 30 40 50 60 100 1.5 72x72, 96x96
PM1500-A 0~9999A (1A/5A CT input); 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96
PM300-AC X /1A ( X: 10~3000A ) ; X/5A (X: 10~3000A) 1.5 72x72, 96x96
PM1500-V 0~600V AC; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96 1.5 72x72, 96x96
PM300-VD V : 10 25 40 60 100 150 250 300 450 500 600
PM1500-Hz 45~66Hz; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.02Hz 48x96, 72x72, 96x96 PM300-VP External PT Operated X/100V X/110V X/120V
PM1500-PF 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.02Hz 48x96, 72x72, 96x96

PM1500-W 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96

PM1500-C 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus A/V : 0.5%; Hz: 0.02 48x96, 72x72, 96x96 ESAC PM500 SERIES Moving Coil Movement
PM1500-M 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96

Model Measurement Range Accuracy Size


PM500-uA uA : 50 100 150 250 800 DC current 1.5 72x72, 96x96
Pm3000 SERIES Three Phase
PM500-mA mA : 4-20 1 10 500 800 DC current 1.5 72x72, 96x96

PM500-A A : 1 2 3 4 5 10 15 20 25 30 40 50 DC current 1.5 72x72, 96x96


Model Power Supply Accuracy Size
PM500-V V : 0.5 1 10 25 50 100 250 500 600 DCVoltage 1.5 72x72, 96x96
PM3000-A 0~9999A (1A/5A CT input) 0.5% 72x72, 96x96

PM3000-V 0~600V AC 0.5% 72x72, 96x96

PM3000-Hz 45~66Hz 0.02Hz 72x72, 96x96 ESAC PM600 SERIES Moving Coil Movement
PM3000-W 0~600V AC; 1A/5A CT input 0.5% 72x72, 96x96

PM3000-Var 0~600V AC; 1A/5A CT input 1% 72x72, 96x96


Model Specificatioins Accuracy Size
PM3000-PF 0~600V AC; 1A/5A CT input 0.01 72x72, 96x96 PM600-W 1Ph 2W ; 100V / 220V / 230V ; 1A / 5A CT Inputs 1.5 72x72, 96x96
PM600-Var 1Ph 2W ; 100V / 220V / 230V ; 1A / 5A CT Inputs 1.5 72x72, 96x96
PM630-W 3Ph 3W ; 100V / 220V / 380V / 400V ; 1A / 5A CT Inputs 1.5 72x72, 96x96
Pm3500 SERIES Three Phase PM630-Var 3Ph 3W ; 100V / 220V / 380V / 400V ; 1A / 5A CT Inputs 1.5 72x72, 96x96

PM640-W 3Ph 4W ; 220(380)V / 230(400)V / 240(415)V ; 1A / 5A CT Inputs 1.5 72x72, 96x96


Model Power Supply Accuracy Size PM640-Var 3Ph 4W ; 220(380)V / 230(400)V / 240(415)V ; 1A / 5A CT Inputs 1.5 72x72, 96x96
PM3500-A 0~9999A (1A/5A CT input); 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 72x72, 96x96

PM3500-V 0~600V AC; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 72x72, 96x96

PM3500-Hz 45~66Hz; 2xDI; 2x DO; RS485 Modbus 0.02Hz 72x72, 96x96 ESAC PM700 SERIES Moving Coil Movement
PM3500-PF 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.02Hz 72x72, 96x96
PM3500-W 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 72x72, 96x96
Model Measurement Range Accuracy Size
PM3500-Var 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 1% 72x72, 96x96
PM700-Hz 45 ~ 55 Hz ; 45 ~ 65 Hz ; 55 ~ 65 Hz 1.5 72x72, 96x96
PM3500-C 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 3x AO; RS485 Modbus A/V : 0.5%; Hz: 0.02 72x72, 96x96
PM700-PF 0.5 lead ~ 1.0 ~ 0.5 Lag ; 110V / 220V / 380V / 415V 2.5 72x72, 96x96
PM3500-M 0~600V AC; 1A/5A CT input; 4xDI; 2x DO; 2x AO; RS485 Modbus 0.5% 72x72, 96x96

13 Product Catalog EASTRON Product Catalog EASTRON 14


OVERDIN-RAIL
SMART VIEW METER

ESP-2 SERIES Ethernet Gateway ESCT-RJ SERIES 3-in-1

Model Input Output Power supply Model Primary Current Secondary Output Accuracy
ESP-2100 RS232/485/422 x1; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 350W ESCT-RJ335 60~250A 333mV / 100mV / 100mA 0.5 / 1
ESP-2200 RS232/485/422 x2; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W ESCT-RJ345 250~630A 333mV / 100mV / 100mA 0.5 / 1
ESP-2400 RS232/485/422 x4; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W
ESP-2800 RS232/485/422 x8; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W
ESP-2120 M-Bus EN13757-3; 300~9600bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W ESCT-SC SERIES 3-in-1

Model Primary Current Secondary Current Accuracy


ESP-4 SERIES wifi Gateway ESCT-SC325 60,100,125,150,200A 5A /1A 0.5 / 1

ESCT-SC335 60,100,125,200,250A 5A /1A 0.5 / 1

Model Input Output Power supply ESCT-SC345 250,300,400,500,600,630A 5A /1A 0.5 / 1


ESP-4142 RS232/485/422; 1200~115200bps Wifi IEEE802.11b/g/n 9~24V DC 310mA
ESP-4104 RS232/485/422; 1200~115200bps Wifi IEEE802.11b/g/n ; Ethernet TCP 10/100M 9~24V DC, 1W

ESCT-C SERIES 3-in-1

ESP-5 SERIES GPRS DTU Gateway


Model Primary Current Secondary Current Accuracy
ESCT-C325 60,100,125,150,200A 5A /1A 0.5 / 1

Model Input Output Power supply ESCT-C335 60,100,125,200,250A 5A /1A 0.5 / 1


ESP-5100 RS232/485/422; 1200~115200bps GPRS 900Mhz/1800Mhz ; Ethernet TCP 9~24V DC, 170mA@9V 0.5 / 1
ESCT-C345 250,300,400,500,600,630A 5A /1A
ESP-5305 RS232/485/422; 1200~115200bps 3G / 4G ; Ethernet TCP 9~24V DC, 200mA@9V

ESCT-B SERIES Split Core


ESP-6 SERIES Lora Gateway

Model Primary Current Secondary Current Accuracy


Model Input Output Power supply ESCT-B23 100,200,250,300,400A 5A /1A 0.5 / 1
ESP-6100 LoRa 470/433Mhz Ethernet TCP 10/100M 9~24V DC, 2W
ESCT-B58 250,300,400,500,600,750,800,1000A 5A /1A 0.5 / 1
ESP-6200 LoRa 470/433Mhz GPRS 900Mhz/1800Mhz ; Ethernet TCP 9~24V DC, 2W 0.5 / 1
ESCT-B88 200,300,400,500,600,750,800,1000A 5A /1A
ESCT-B812 500,600,750,800,1000,1200,1250,1500A 5A /1A 0.5 / 1

ESCT-B816 1000,1500,2000,3000,4000,5000A 5A /1A 0.5 / 1


EST485 SERIES Pulse Collector

Model Input Output Power supply ESCT-T SERIES Split Core

EST485-P16 Passive Pulse x16 Rs485 Modbus 24V DC; 220V AC


EST485-P32 Passive Pulse x32 Rs485 Modbus 24V DC; 220V AC Model Primary Current Secondary Current Accuracy
ESCT-T24 100,150,200,250,300A 5A /1A 0.5 / 1

ESCT-T36 100,150,200,300,400,500,600A 5A /1A 0.5 / 1

ESCT-TU SERIES Split Core

Model Primary Current Secondary Current Accuracy


ESCT-TU10 5,10,20,50,75 A 333mV / 100mV / 100mA 0.5 / 1
ESCT-TU16 5,10,50,100,150 A 333mV / 100mV / 100mA 0.5 / 1
ESCT-TU24 10,50,100,250,300A 333mV / 100mV / 100mA 0.5 / 1

ESCT-TU36 20,100,250,400,600 A 333mV / 100mV / 100mA 0.5 / 1

15 Product Catalog EASTRON Product Catalog EASTRON 16


OVERDIN-RAIL
SMART VIEW METER

ESCT-U SERIES Split Core ESRD TMS SERIES Digital multifunction time relay

Model Primary Current Secondary Current Accuracy


Model Specifications Description Size
ESCT-U75 5,10,50,75,100,125,150,200 A 333mV 0.5 / 1
ESRD-TMS1 AC/DC 24-240V,50/60Hz 1C/O+1NO contacts, 0s-99h59min59sec, Backlit, LCD disply 2 Module
ESCT-U125 50,100,125,200,250,400,600,630A 333mV 0.5 / 1
ESRD-TMS2 AC/DC 24-240V,50/60Hz 1C/O+1NO contacts,0-9999s,0-9999min , Backlit, LCD disply 2 Module
ESCT-U200 100,250,400,630,800,1000,2000A 333mV 0.5 / 1

ESCT-U250 200,250,400,630,1500,2500,3000A 333mV 0.5 / 1

ESCT-U300 400,800,1000,1500,2500,3000,5000A 333mV 0.5 / 1 ESRD TPA SERIES Single channel astronomical time switch

ESCT-RC SERIES Rogowski Coil Model Specifications Description Size

ESRD-TPA1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
Model Primary Current Secondary Output Accuracy
ESCT-RC60 100A 333mV / 100mV 0.5 / 1
ESCT-RC76 200A 333mV / 100mV 0.5 / 1 ESRD TPW SERIES Digital weekly time switch
ESCT-RC90 400A 333mV / 100mV 0.5 / 1
ESCT-RC100 800A 333mV / 100mV 0.5 / 1
Model Specifications Description Size
ESCT-RC150 1000A 333mV / 100mV 0.5 / 1
ESRD-TPW1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
ESCT-RC160 1200A 333mV / 100mV 0.5 / 1
ESRD-TPW2 AC/DC24-264V,50/60Hz Double Channel,100 programs, Backlit, LCD , Holiday mode, Automatic 2 Module
ESCT-RC190 3000A 333mV / 100mV 0.5 / 1
ESCT-RC200 5000A 333mV / 100mV 0.5 / 1
ESCT-RC300 6000A 333mV / 100mV 0.5 / 1
ESRD ST SERIES Twilight switch

ESCT-ABO SERIES Solid Core


Model Specifications Description Size
ESRD-ST1 230V,50/60Hz, 1NO Fixed waitching on and off delay, LED indication 2 Module
Model Primary Current Secondary Output Accuracy
ESCT-ABO30 50,60,75,80,100,150,200,250,300A 5A 0.5S / 0.5

ESCT-ABO40 75,80,100,150,200,250,300,400,500A 5A 0.5S / 0.5 ESRS TM SERIES Multifunction time relay


ESCT-ABO60 200,250,300,400,500,600,750,800,1000A 5A
ESCT-ABO100 800,1000,1200,1500,1600,2000,2500,3000A 5A
Model Specifications Description Size
ESRS-TM11 AC 220V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module

ESRS-TM12 A1-A2:AC220V; A3-A2; AC/ DC24V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
ESCT-DM SERIES Solid Core
ESRS-TM14 AC/DC 12-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module

ESRS-TM23 AC/DC 24-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
Model Primary Current Secondary Output Accuracy
ESCT-DM20/30 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESCT-DM20/35 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESRS TSL SERIES Staircase light timer

Model Specifications Description Size


ESRS-TSL 230V,50/60Hz 3 operation modes, 3 wire or 4 wire connection 1 Module

17 Product Catalog EASTRON Product Catalog EASTRON 18


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0·5%
Operational voltage 80%~120% of Un Frequency 0·2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120 Modbus / Mbus/Pulse - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 45A Active energy (Wh) Class 1
45A direct load Operational current range 0.4% Ib-Imax
One module 17.5mm wide Over current withstand 30 Imax for 0.01s Modbus
Measuring kWh,W, V, A, PF, Hz, dmd.etc. Operational frequency range 50 / 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps
1-247
RS485 Modbus or M-bus communication Max reading 999999 kWh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120-45A series are advanced single phase energy monitoring solution with built-in configuration push button and LCD data displaying, Primary Address 1 to 250
Degree of pollution 2
particularly indicated for energy and other parameters metering and for cost allocation. Housing for DIN-rail mounting, IP51 protection degree, Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
direct connection up to max 45A. Moreover the meter can be provided with a pulses output proportional to the active energy being measured
Insulating encased meter of protective class II
and a RS485 output/ M-bus output port for remote monitoring. It is an ideal choice as a sub-meter for AMR system or SCADA system.
Aititude up to 2000m Pulse output
Electrostatic discharges 8kV contact / 15kV air gap Pulse outputs 2
This series has been assessed and certified as meeting the requirements of EC Directive 2014/32/EU. Electromagnetic HF fields IEC 61000-4-3 Pulse output type Passive
The EC Type Examination Certificate Number is 0120/SGS0141. Electrical fast transients 4kV Configurable
Pulse Output 1
Surge 4kV Pulse width 200/100(default)/60ms
Radiated & conducted emissions EN 55022 Pulse output 2 1000imp/kWh

Wiring diagram Dimensions

SDM120 —M—1—1
17
.5
m
m

MBUS 1 MBUS 2
SDM120Mbus
P: Multi-parameters, 2 Pulse outputs
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication
G B A
120Modbus

62mm
1: 110V/120V AC
2: 220V/230V AC
35mm

1: MID
2: Non-MID Height 119mm
Width 17.5mm
Depth 62mm

19 Product Catalog EASTRON Product Catalog EASTRON 20


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120CT Modbus / Mbus / Pulse - AC voltage withstand
- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Primary current 5~9999A Reactive energy(Varh) Class 2
Secondary input 100mV or 100mA Active energy (Wh) Class 1
CT operated Over current withstand 20 Imax for 0.01s
One module 17.5mm wide Operational frequency range 50 or 60Hz Modbus
Internal power consumption ≤ 2W/10VA
Measuring kWh,W, V, A, PF, Hz, dmd. etc. Bus type RS485(semi-duplex)
Pulse output 1 configurable
Bi-directional measurement Protocol Modbus RTU
Pulse output 2 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps
1-247
RS485 Modbus or M-bus communication Max reading 999999 kWh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120 CT series is CT operated type single phase multi-function energy meter. The meter is compactly designed in one module din rail enclosure. Primary Address 1 to 250
LCD display is provided to show the energy and other important electric parameters measured. Moreover the meter can provide with pulse outputs Degree of pollution 2
Secondary Address 00 00 00 01 to 99 99 99 99
proportional to the energy being measured and a RS485 output/ M-bus output port for remote monitoring. CT ratio can be set, which enables this P rotection against penetration of dust and water IP51(indoor)
meter to measure big current load. II
Insulating encased meter of protective class
Aititude up to 2000m
This series has been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. Electrostatic discharges 8kV contact / 15kV air gap
The EC Type Examination Certificate Number is 0120/SGS0141. IEC 61000-4-3
Electromagnetic HF fields
Electrical fast transients 4kV
Surge 4kV
Radiated & conducted emissions EN 55022

Wiring diagram Dimensions

SDM120—CT—M—1—1

CT: 5A CT operated type


17
MV: 100mV CT operated type .5
m
G B A m

G B A
P: Multi-parameters, 2 Pulse outputs SDM120CT-Modbus
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication

MBUS 1 MBUS 2

SDM120CT-Mbus

62mm
1: 110V/120V AC
2: 220V/230V AC

35mm
1: MID
2: Non-MID

S2
P1
Height 119mm
Width 17.5mm
Depth 62mm

21 Product Catalog EASTRON Product Catalog EASTRON 22


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)

SDM220 Modbus / Mbus / MT / Std / Pulse - AC voltage withstand


- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power
Reactive power
±1% of range maximum
±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 100A Active energy (Wh) Class 1
100A direct load Operational current range 0.4% Ib-Imax
Over current withstand 30 Imax for 0.01s Modbus
2 Module 36mm wide
Operational frequency range 50 or 60Hz
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Protocol Modbus RTU
Bi-directional measurement Pulse output 1 configurable
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs Pulse output 2 1000imp/kWh
Address range 1-247
Max reading 99999.99 kWh
RS485 Modbus or M-bus communication Max. Bus loading 64pcs
MID Communication distance 1000M
Multi-tariffs
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C M-bus
Reference temperature 23°C± 2°C M-bus
Bus type
International standard IEC 62053-21 / EN50470-1/3 EN13757-3
Protocol
Accuracy class Class1/Class B 300/600/1200/2400/4800/9600
Baud rate
Introduction Installation category
Mechanical environment
CAT II Parity NONE/EVEN/ODD
M1 Stop bits 1 or 2
Electromagnetic environment E2 1 to 250
SDM220 series is an advanced digital single phase multi-function energy meter, which measures up to 100A direct load. The unit measures active Primary Address
Degree of pollution 2 00 00 00 01 to 99 99 99 99
energy, reactive energy, current, voltage, power, power factor, frequency, demand, etc. Bi-directional measurement makes this unit an ideal choice Secondary Address
P rotection against penetration of dust and water IP51(indoor)
for Solar PV measurement. A remote communication port is provided, RS485 Modbus RTU or M-bus EN13757-3 and Communication parameters are
Insulating encased meter of protective class II
password protected in setup mode. User can check data and set up the meter via the buttons on the front panel. Pulse Output
Pulse outputs 2
This Series has been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. Multi-tariff Pulse output type Passive
The EC Type Examination Certificate Number is 0120/SGS0172. time clock accuracy ﹤1s/day Pulse Output 1 Configurable
Tariff 4 Pulse width 200/100(default)/60ms
Time segments 10 Pulse output 2 1000imp/kWh

Wiring diagram Dimensions

2 1 GND B A
SDM220 —M—1—1
4 5 6 7 8 9 PULSE OUTPUT RS485 PORT
P : Multi-parameters,2 Pulse outputs SDM220-Modbus 45m
m
Std: kWh,2 Pulse outputs, RS 485 Modbus 4 5 6 7 8 9 SDM220-MT
M: Multi-parameters,2 Pulse outputs, Modbus
MB: Multi-parameters,2 Pulse outputs, M-Bus
MT:: Multi-parameters,2 Pulse outputs,4 Tariffs, Modbus 2 1

47mm
PULSE OUTPUT
1:110/120V SDM220-Pulse

62 mm
2:220/230V 4 5 6 7 8 9

1: MID
2 1 BUS1 BUS2
2: Non-MID
mm
1 2 3 35
PULSE OUTPUT MBUS PORT mm
90

m
6m
SDM220-Mbus
4 5 6 7 8 9

3
100A
L IN L OUT Height 90mm
N Width 36mm
Depth 62mm

23 Product Catalog EASTRON Product Catalog EASTRON 24


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM 230 Modbus / Mbus / 2T / Std / Pulse - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 100A Active energy (Wh) Class 1
100A direct load Operational current range 0.4% Ib-Imax
2 Module 36mm wide Over current withstand 30 Imax for 0.01s Modbus
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Operational frequency range 50 or 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1 1000imp/kWh
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs Pulse output 2 1000imp/kWh(only for SDM230DR/Bi)
Address range 1-247
RS485 Modbus or M-bus communication Max reading 999999.9 kWh
Max. Bus loading 64pcs
2 Tariffs available MID Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM230 series is an advanced digital single phase multi-function energy meter, which measures up to 100A direct load. The unit measures active Primary Address 1 to 250
Degree of pollution 2
energy, reactive energy, current, voltage, power, power factor, frequency, demand, etc. Bi-directional measurement makes this unit an ideal choice Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
for Solar PV measurement. A remote communication port is provided, RS485 Modbus RTU or M-bus EN13757-3 and Communication parameters are
Insulating encased meter of protective class II
password protected in setup mode. User can check data and set up the meter via the buttons on the front panel. SDM230-2T can measure energy from
two different power supplies. Electrostatic discharges 8kV contact / 15kV air gap Pulse Output
Electromagnetic HF fields IEC 61000-4-3 Pulse outputs 2
This Series has been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. Electrical fast transients 4kV Pulse output type Passive
The EC Type Examination Certificate Number is 0120/SGS0206. Surge 4kV Pulse Output 1 Configurable
Radiated & conducted emissions EN 55022 Pulse width 200/100(default)/60ms
Pulse output 2 1000imp/kWh

Wiring diagram Dimensions


100A
L-in L-out
SDM230 —A—1—1—B

230V/2T 45mm

DR: kWh + kW, Resettable Energy, Pulse output SDM230-2T


1 2 15 16
BI: Import/export/total kWh and Power, resettable Energy,Pulse putput
15 16
P: Multi-parameters, 2 Pulse outputs
M: Multi-parameters, 2 pulse outputs, RS 485 Modbus
2T:Multi-parameters, 2 pulse outputs, RS 485 Modbus, 2 Tariffs 5 6 7 8 9 10 SDM230-2T
SDM230Std

63mm
1:110/120V
A B GND 1+ COM 2+
SDM230Modbus
2:220/230V
5 6 7 8 9 10
1: MID SDM230Mbus
2: Non-MID Mbus1 Mbus2 1+ COM 2+ 36
5 6 7 8 9 10
m
m 35mm
99mm
B:Class 1 5 6 7 8 9 10

C: Class 0.5s SDM230-Pluse


1+ COM 2+

3 4 Height 99mm
Width 36mm
N-in N-out
Depth 63mm

25 Product Catalog EASTRON Product Catalog EASTRON 26


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM530 Modbus / Mbus / MT - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
THREE PHASE 4 WIRE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 10A Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
100A direct load Over current withstand 30 Imax for 0.01s
7 Module wide Operational frequency range 50 or 60Hz
Modbus
Power consumption per phase ≤ 2W/10VA
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Bus type RS485(semi-duplex)
Display LCD
Bi-directional measurement Protocol Modbus RTU
Max reading 999999.99 kWh/kVarh
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs
Address range 1-247
RS485 Modbus or M-bus communication Performance criteria Max. Bus loading 64pcs
Operating humidity ≤ 90%
Multi-tariffs Communication distance 1000M
Storage humidity ≤ 95%
Parity EVEN/ODD/NONE
Operating temperature -25°C - +55°C
Data bit 8
Storage temperature -40°C - +70°C
Stop bit 1
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3
Accuracy class Class1/Class B M-bus
Installation category CAT III Bus type M-bus
Mechanical environment M1 Protocol EN13757-3
Electromagnetic environment E2 Baud rate 300/600/1200/2400/4800/9600
Introduction Degree of pollution 2 Parity NONE/EVEN/ODD
P rotection against penetration of dust and water IP51(indoor) Stop bits 1 or 2
The SDM530 100A series measure and display the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, current, Primary Address 1 to 250
Insulating encased meter of protective class II
power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured 00 00 00 01 to 99 99 99 99
Electrostatic discharges 8kV contact / 15kV air gap Secondary Address
over preset periods of up to 60 minutes. In order to measure energy, the unit requires voltage and current inputs in addition tot he supply required
Electromagnetic HF fields IEC 61000-4-3
to power the product.
Electrical fast transients 4kV Pulse Output
SDM530 100A series support max.100A direct connection, save the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective Pulse outputs 2
and easy operation. Built-in interfaces provides pulse and RS485 Modbus RTU outputs/ Mbus Port. All the configuration are password protected. Pulse output type Passive
Multi-tariff
time clock accuracy ﹤1s/day Pulse Output 1 Configurable
Tariff 4 Pulse width 200/100(default)/60ms
Time segments 10 Pulse output 2 400imp/kWh

Wiring diagram Dimensions

SDM530—M—4—4—C

Std: kWh/kVarh,Pulse output+RS485 Modbus RTU


M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU B A GND 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication 2 1

DO: “M” + Digital Output


24 23 22 21 20 19

65mm
49mm
1: 127/220V
2: 230/400V SDM530Modbus/MT
1: Single tariff 1 2 3 4 5 6 7
BUS1 BUS2
2: 2 Tariffs 2 1
10
35
mm
4: 4 Tariffs 0m
m
mm
125
L1
B:Class 1 24 23 22 21 20 19
L2
C: Class 0.5s SDM530Mbus
D: Class 0.2s L3

N Height 100mm
Width 125mm
Depth 65mm

27 Product Catalog EASTRON Product Catalog EASTRON 28


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)

SDM530CT Modbus / Mbus / MT - AC voltage withstand


- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power
Reactive power
±1% of range maximum
±1% of range maximum
THREE PHASE FOUR WIRE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
5A CT operated Over current withstand 20 Imax for 0.01s
Operational frequency range 50 or 60Hz
7 Module wide Modbus
Power consumption per phase ≤ 2W/10VA
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Bus type RS485(semi-duplex)
Display LCD
Protocol Modbus RTU
Bi-directional measurement Max reading 999999.99 kWh/kVarh
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs Address range 1-247
RS485 Modbus or M-bus communication Performance criteria Max. Bus loading 64pcs
Operating humidity ≤ 90% Communication distance 1000M
Multi-tariffs
Storage humidity ≤ 95% Parity EVEN/ODD/NONE
Operating temperature -25°C - +55°C Data bit 8
Storage temperature -40°C - +70°C Stop bit 1
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3
Class1/Class B
M-bus
Accuracy class
Bus type M-bus
Installation category CAT III
Protocol EN13757-3
Mechanical environment M1
Baud rate 300/600/1200/2400/4800/9600
Electromagnetic environment E2
Introduction Degree of pollution 2
Parity NONE/EVEN/ODD
1 or 2
Stop bits
P rotection against penetration of dust and water IP51(indoor)
Primary Address 1 to 250
Insulating encased meter of protective class II
The SDM530 CT series measure and display the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, current, power, active and reactive energy, Secondary Address 00 00 00 01 to 99 99 99 99
Electrostatic discharges 8kV contact / 15kV air gap
imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60 minutes. In order to measure energy,
Electromagnetic HF fields IEC 61000-4-3
the unit requires voltage and current inputs in addition tot he supply required to power the product.
Electrical fast transients 4kV Pulse Output
SDM530CT series can be configured to work with a wide range of CTs, giving the unit a wide range of operation. Built-in interfaces provides pulse and RS485 Modbus or Mbus. Pulse outputs 2
Configuration is password protected. Pulse output type Passive
Multi-tariff
﹤1s/day Pulse Output 1 Configurable
time clock accuracy
4 Pulse width 200/100(default)/60ms
Tariff
10 Pulse output 2 1000imp/kWh
Time segments

Wiring diagram Dimensions

SDM530CT—M—4—4—C
L1 L2 L3 N

Std: kWh/kVarh,Pulse output+RS485 Modbus RTU


M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8
B A GND
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication 2 1

DO: “M” + Digital Output


24 23 22 21 20 19

65mm
49mm
1: 127/220V
2: 230/400V SDM530CT-Modbus/MT

1: Single tariff 1 2 3 4 5 6 7
BUS1 BUS2 35
2: 2 Tariffs 2 1
10
mm
0m
4: 4 Tariffs m
mm
125
L1 S1
24 23 22 21 20 19 P1
B:Class 1 L2
S1
C: Class 0.5s SDM530CT-Mbus P1
S1
L3
D: Class 0.2s P1

N
Height 100mm
Width 125mm
Depth 65mm

29 Product Catalog EASTRON Product Catalog EASTRON 30


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)

SDM630 Modbus / Mbus / MT / Std / Pulse/2T - AC voltage withstand


- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power
Reactive power
±1% of range maximum
±1% of range maximum
THREE PHASE MULTI-FUNCTION POWER ANALYZER Basic current (Ib) 10A Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
100A direct load Over current withstand 30 Imax for 0.01s

Work with 3P4W / 3P3W / 1P2W Operational frequency range 50 or 60Hz


Modbus
Power consumption per phase ≤ 2W/10VA
4 Module wide Bus type RS485(semi-duplex)
Display LCD
Protocol Modbus RTU
Measures kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,THD,etc. Max reading 999999.99 kWh/kVarh
Baud rate 2400/4800/9600/19200/38400bps
Bi-directional measurement
Address range 1-247
2 Pulse outputs Performance criteria Max. Bus loading 64pcs
Operating humidity ≤ 90% Communication distance 1000M
RS485 Modbus or M-bus communication
Multi-tariffs available MID Storage humidity
Operating temperature
≤ 95%
-25°C - +55°C
Parity EVEN/ODD/NONE
Data bit 8
Storage temperature -40°C - +70°C Stop bit 1
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3
Accuracy class Class1/Class B
M-bus
Bus type M-bus
Installation category CAT III
Protocol EN13757-3
Mechanical environment M1
Baud rate 300/600/1200/2400/4800/9600
Electromagnetic environment E2
Introduction Degree of pollution 2
Parity
Stop bits
NONE/EVEN/ODD
1 or 2
P rotection against penetration of dust and water IP51(indoor)
Primary Address 1 to 250
Insulating encased meter of protective class II
The SDM630 100A series is a three phase multifunction DIN rail meter. It can measure and display the characteristic of 1p2w,3p3w and 3p4w supplies, including voltage, current, power, Secondary Address 00 00 00 01 to 99 99 99 99
Electrostatic discharges 8kV contact / 15kV air gap
active and reactive energy imported or exported. Energy is measured in terms of kWh, kVarh. Max demand current can be measured over preset periods of up to 60 minutes. The SDM630 Electromagnetic HF fields IEC 61000-4-3
100A series has wonderful industrial design, big size LCD and touch buttons. All electronic parameters can be set with the button and the configuration is password protected. It can Electrical fast transients 4kV Pulse Output
directly connect to 100A max. Saving the cost to install external CT. Built-in interfaces provides pulse and RS485 Modbus RTU outputs. Pulse outputs 2
Pulse output type Passive
Multi-tariff
﹤1s/day Pulse Output 1 Configurable
SDM630 Series have been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. The instrument traceable number is 0120/SGS0151 time clock accuracy
4 Pulse width 200/100(default)/60ms
Tariff
10 Pulse output 2 400imp/kWh
Time segments

Wiring diagram Dimensions


L1 L2 L3 N L1 L3 L2 L1 N
SDM630 —M—4—1—C
2 3 4 2 3 4 2 3 4 m
1 1 1 45m

P: Multi-parameters, 2 Pulse outputs


Std: kWh/kVarh,Pulse output+RS485 Modbus RTU
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication 3p4w 3p3w 1p2w

1: Single tariff
2: 2 Tariffs
4: 4 Tariffs
5 6 7 8 5 6 7 8 5 6 7 8
1: MID 72 35m
m
m mm
2: Non-MID m 100

L1 L2 L3 N L1 L3 L2 L1 N

B:Class 1
C: Class 0.5s
D: Class 0.2s SDM630Modbus SDM630Pulse SDM630Mbus Height 100mm
SDM630Standard Width 72mm
SDM630MT
Depth 66mm
SDM630-2T

31 Product Catalog EASTRON Product Catalog EASTRON 32


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)

SDM630MCT Modbus/Mbus/2T/MV - AC voltage withstand


- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power
Reactive power
±1% of range maximum
±1% of range maximum
THREE PHASE MULTI-FUNCTION POWER ANALYZER Rated current (Ib) 5A CT or 333mV CT input Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
CT & PT operated Over current withstand 20 Imax for 0.01s
Work with 3P4W / 3P3W / 1P2W Operational frequency range 50 or 60Hz
Modbus
Power consumption per phase ≤ 2W/10VA
4 Module wide Bus type RS485(semi-duplex)
Pulse output 1 Configurable
Measures kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,THD,etc. Protocol Modbus RTU
Pulse output 2 3200 imp/kWh
Baud rate 2400/4800/9600/19200/38400bps
Bi-directional measurement Display LCD
Address range 1-247
2 Pulse outputs Max reading 9999999.9 kWh/kVarh
Max. Bus loading 64pcs
RS485 Modbus or M-bus communication Communication distance 1000M
2 Tariffs available MID Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT III
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
The SDM630M CT Series is a three phase multifunction DIN rail meter. It can measure and display the characteristic of 1p2w,3p3w and 3p4w supplies, including voltage, current, power, active Primary Address 1 to 250
Degree of pollution 2
and reactive energy imported or exported. Energy is measured in terms of kWh, kVarh. Max demand current can be measured over preset periods of up to 60 minutes. In order to measure energy, Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
the unit requires voltage and current inputs in addition to the supply required to the power the meter. The required current inputs are obtained via current transformers. This meter can be Insulating encased meter of protective class II
configurable to work with a wide range of CTs, giving the unit a wide range of operation. Build-in interface provides pulse and RS485 Modbus RTU outputs. And the configuration is Electrostatic discharges 8kV contact / 15kV air gap
password protected. Radiated & conducted emissions EN 55022

SDM630 CT Series have been assessed and certified as meeting the requirements of EC Directive 2014/32/EU. The instrument traceable number is 0120/SGS0142

Wiring diagram Dimensions

SDM630MCT
SDM630MCT-MV

SDM630MCT—5—J—2—4—1—C
1: 100mA
2: 100mV
SDM630MCT-2T
3: 333mV M:Modbus
5: 1A & 5A MB: M-Bus
L: LoRa
W: Wifi

1: Self-power supply
2: Aux. AC power supply
SDM630MCT-Mbus Height 94.5mm
3: Aux. DC power supply 1: Single tariff Width 72mm
2: 2 Tariffs Depth 65mm
4: 4 Tariffs
1: MID
2: non-MID B:Class 1
C: Class 0.5s
D: Class 0.2s

33 Product Catalog EASTRON Product Catalog EASTRON 34


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)

SDM630MCT-RJ/2L - AC voltage withstand


- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power
Reactive power
±1% of range maximum
±1% of range maximum
THREE PHASE 4 WIRE ENERGY METER Rated current (Ib) 100mA or 333mV CT input Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
CT operated Over current withstand 20 Imax for 0.01s
Plug-in connection Operational frequency range 50 or 60Hz
Modbus
Power consumption per phase ≤ 2W/10VA
RJ12 100mA/333mV current input Bus type RS485(semi-duplex)
Pulse output 1 Configurable
Multi-parameter measured Protocol Modbus RTU
Pulse output 2 3200 imp/kWh
Baud rate 2400/4800/9600/19200/38400bps
THD of voltage and current Display LCD
Address range 1-247
RS485 Modbus RTU and Pulse outputs Max reading 9999999.9 kWh/kVarh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
M-bus (Optional)
Reference temperature 23°C± 2°C
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT III
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
The SDM630MCT-RJ is a three phase 4 wire multi-function energy meter. it measures and displays the characteristic of 3p4w network, including voltage, current, power , active and Primary Address 1 to 250
Degree of pollution 2
reactive energy imported and exported, THD, power demand, frequency, power factor etc. The meter use plug-in terminals for both voltage input and current input. With 3-in-1 Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
Current Transformer (ESCT-RJ), the meter provides an easy, quick and error-free connection solution. Equipped with RS485 communication port and 2 pulse outputs, the meter is an II
Insulating encased meter of protective class
ideal product for sub-metering in low voltage application. Electrostatic discharges 8kV contact / 15kV air gap
Radiated & conducted emissions EN 55022

Wiring diagram Dimensions

RS485 333mV CT 333mV CT


RJ-12 RJ-12
12 13 14
ESCT-SC ESCT-SC
G B A
SECT-RJ SECT-RJ

Current connection cable between L1


S1
100mA/333mV CT and the meter. S1

S1
P1
S1
P1
L2
P1 P1
Rj12 socket for S1 S1
L3
fast connection and to P1 P1

eliminate wiring errors N

L1
L2 1 2 3 4
L3 Height 94.5mm
N MEASURED VOLTAGE
Width 72mm
The example shows a wiring in 3p4w network. 3 PHASE 4 WIRE Depth 65mm
Plug-in terminals for voltage inputs.
Self power supply from L1.

35 Product Catalog EASTRON Product Catalog EASTRON 36


SMART
SMART DIN-RAIL METER
DIN-RAIL

Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM630-2C - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
DUAL LOAD MULTI-FUNCTION ENERGY METER Rated current (Ir) 5A or 333mV CT input Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
Over current withstand 20 Imax for 0.01s
2 Meters in 1
Operational frequency range 50 or 60Hz
Easy and error free connection ≤ 2W/10VA Modbus
Power consumption per phase
5A / 333mV CT input Pulse output Configurable Bus type RS485(semi-duplex)
Multi-parameter measured Display LCD Protocol Modbus RTU
Max reading 9999999.9 kWh/kVarh Baud rate 2400/4800/9600/19200/38400 bps
RS485 Modbus RTU
Address range 1-247
2 Pulse outputs
Max. Bus loading 64pcs
Performance criteria Communication distance 1000M
Operating humidity ≤ 90% Parity EVEN/ODD/NONE
Storage humidity ≤ 95% Data bit 8
Operating temperature -25°C - +55°C Stop bit 1
Storage temperature -40°C - +70°C
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3 Pulse Output
Accuracy class Class1/Class B Pulse outputs 2
Installation category CAT III Pulse output type Passive
Introduction Mechanical environment M1 Pulse Output 1 C1 Configurable
Electromagnetic environment E2 Pulse output 2 C2 Configurable

The SDM630-2C is a dual load three phase 4 wire multi-function energy meter for measuring energy consumption in split load applications such as Power and lighting loads. The meter Degree of pollution 2 Pulse width 200/100(default)/60ms

measures 2 three phase circuits separately and display the parameters including voltage, current, power, power factor, frequency, demand, active energy, reactive energy etc. P rotection against penetration of dust and water IP51(indoor)
Insulating encased meter of protective class II
Electrostatic discharges 8kV contact / 15kV air gap
The meter connect with 3-in-1 CT via wiring looms for plug-in connection. It is a cost-effective and space saving solution for all new power and lighting, or dual load, distribution and
Electromagnetic HF fields IEC 61000-4-3
panel boards. ESCT-SC series current transformer provides a range of CT with primary current up to 630A.
Electrical fast transients 4kV
Surge 4kV
Radiated & conducted emissions EN 55022

DUAL LOAD SOLUTION Wiring diagram Dimensions


Three phase 3-in-1 Current Transformer with
plug-in terminal and wiring looms for quick 2 circuits 3p4w
and error-free installation.

Circuit 2
Current connection cable between CT3

5A/333mV CT and the meter. CT2


CT1
Cable Length up to 5M.

Circuit 1
CT3

65mm
CT2
CT1

L32 L31 L22 L21 L12 L11 L32 L31 L22 L21 L12 L11

ESCT-SC CT input for Circuit1 CT input for Circuit2

m
Voltage input - --- 1 - --- 2 - RS485 10 35m

--
- --

-
5m
ESCT-SC N L3 L2 L1 - - - B A m m

-
GND

92m
1A fast blow fuses

L1 N L3 L2 L1 Height 92mm
Voltage connection cable between L2
L3 SDM630MCT-2C, SDM630MV-2C Width 105mm
network and the meter N Depth 65mm

37 Product Catalog EASTRON Product Catalog EASTRON 38


SMART
SMART DIN-RAIL METER
DIN-RAIL

45A MAX. direct load 100A MAX. direct load


One module wide Two module wide
SDM120 A/D/DB Active energy measured SDM 230A/D Active energy measured
SINGLE PHASE 2 WIRE KWH METER Pulse output MID SINGLE PHASE 2 WIRE KWH METER Pulse output
Din rail mounted Din rail mounted

Description Specification Description


Specification
Model 120A/120D/120DB Model SDM 230A / SDM230D
SDM120A electromechanical register SDM230A electromechanical register
Display
Display
SDM120 —A—1—1
SDM230D LCD SDM230 —D—1—1
SDM120D LCD
SDM120DB LCD with Backlit Nominal voltage(Un) 120V or 230V ac
A: Analog Register, kWh

Nominal voltage(Un) 120V or 230V ac D: LCD Display, kWh Operational voltage 80%~120% of Un
DB: LCD Display with Backlit, kWh A: Analog Register
Operational voltage 80%~120% of Un Insulation capabilities D: LCD Display

Insulation capabilities - AC voltage withstand 4KV for 1 minute


1: 110V/120V AC
2: 220V/230V AC - Impulse voltage withstand 6KV-1.2µS 1: Without Backlight
- AC voltage withstand 4KV for 1 minute
2: With Backlight
- Impulse voltage withstand 6KV-1.2µS Basic current (Ib) 10A
1: MID
Basic current (Ib) 5A 2: Non-MID Maximum rated current (Imax) 100A
1: 110/120V AC
Maximum rated current (Imax) 45A Operational current range 0.4% Ib-Imax 2: 220V/230V AC
Operational current range 0.4% Ib-Imax Over current withstand 30 Imax for 0.01s
Over current withstand 30 Imax for 0.01s Operational frequency range 50 or 60Hz
Wiring diagrams Internal power consumption ≤ 2W/10VA
Operational frequency range 50 / 60Hz Wiring diagrams
Internal power consumption ≤ 2W/10VA Pulse output 1000imp/kWh
Pulse output 1000imp/kWh Max reading 999999.9 kWh(SDM230A) 100A
L-in L-out

Max reading 99999.9 kWh Pulse output 99999.9 kWh(SDM230D)

Performance criteria 1 2

Performance criteria Operating humidity ≤ 90%


Operating humidity ≤ 90%
Storage humidity ≤ 95%
Storage humidity ≤ 95%
Operating temperature -25°C - +55°C
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
Storage temperature -40°C - +70°C ATTENTION: Pulse output must be fed as shown in the 7 8

Reference temperature 23°C± 2°C


23°C± 2°C wiring diagram below. Scrupulously respect polarities + -
Reference temperature IEC 62053-21 / EN50470-1/3
5 6 7 8 9 10
International standard
International standard IEC 62053-21 / EN50470-1/3 and the connection mode. Opto -coupler with potential
Accuracy class Class1/Class B
Accuracy class Class1/Class B -free SPST-NO Contact.
Installation category CAT II 3 4
Contact range:5~27VDC Max. current
Installation category CAT II
Input:27mA DC. Mechanical environment M1 N-in N-out
Mechanical environment M1
Electromagnetic environment E2
Electromagnetic environment E2
Degree of pollution 2
Degree of pollution 2 Dimensions
P rotection against penetration of dust and water IP51(indoor)
P rotection against penetration of dust and water IP51(indoor) Dimensions Insulating encased meter of protective class II
Insulating encased meter of protective class II 45mm
Aititude up to 2000m
Electrostatic discharges 8kV contact / 15kV air gap 17
Height 99mm
.5
m
Electrostatic discharges 8kV contact / 15kV air gap Width 36mm
Electromagnetic HF fields IEC 61000-4-3 m
Depth 63mm
Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV
Electrical fast transients 4kV
Surge 4kV
Surge 4kV

63mm
Radiated & conducted emissions EN 55022
Radiated & conducted emissions EN 55022
62mm

The SDM120 A/D/DB series provides an uni-direction (anti-reverse)


Mechanics
36
35mm Din rail dimensions 99x36x63 (WxHxD) DIN 43880 35mm
measurement model. It would only counts the forward energy , and m
m
99mm
not counts the reverse energy. Height 119mm Mounting DIN rail 35mm
it is widely used in solar generation energy measurement. Width 17.5mm Sealing IP51 (indoor)
Depth 62mm Material self-extinguishing UL94V-0

39 Product Catalog EASTRON Product Catalog EASTRON 40


SMART
SMART DIN-RAIL METER
DIN-RAIL

100A MAX. direct load 100A MAX. direct load


Active energy + power measured 4 Module wide
SDM 230DR/BI Resettable energy SDM320A/D Active energy measured
SINGLE PHASE 2 WIRE KWH METER
SINGLE PHASE 2 WIRE KWH METER Pulse output MID Pulse output
Din rail mounted IEC62053-21 Class 1

Description
Description Buttons
Specification Specification
Model SDM 230DR / SDM230BI Model SDM320D
Display LCD with Backlit Nominal voltage(Un) 230V ac / 110V ac SDM320 —D—1—1
SDM230 —DR—1—1
Nominal voltage(Un) 120V or 230V ac Operational voltage 80%~120% of Un
Operational voltage 80%~120% of Un Insulation capabilities A: Analog Register
DR: kWh + kW, Resettable Energy, Pulse output - AC voltage withstand
Insulation capabilities 4KV for 1 minute D: LCD Display
BI: Import/export/total kWh and Power,
- AC voltage withstand 4KV for 1 minute resettable Energy,Pulse putput - Impulse voltage withstand 6KV-1.2µS
Basic current (Ib) 1: Without Backlight
- Impulse voltage withstand 6KV-1.2µS 10A
1:110/120V 2: With Backlight
Basic current (Ib) 10A 2:220/230V Maximum rated current (Imax) 100A
Maximum rated current (Imax) 100A Operational current range 0.4% Ib-Imax 1: 110V/1200V AC
1: MID
Operational current range 0.4% Ib-Imax Over current withstand 30 Imax for 0.01s 2: 220V/230V AC
2: Non-MID
Over current withstand 30 Imax for 0.01s Operational frequency range 50 or 60Hz
Operational frequency range 50 or 60Hz Internal power consumption ≤ 2W/10VA
Internal power consumption ≤ 2W/10VA Pulse output 1600imp/kWh Wiring diagrams
Pulse output 1 1000imp/kWh Display LCD
Pulse output 2 1000imp/kWh Max reading 99999.99 kWh
Max reading 999999.9 kWh
Wiring diagrams Terminals 5 & 6: Pulse output
Performance criteria 8 7 6 5

Performance criteria 100A Operating humidity ≤90%


L-in L-out

Operating humidity ≤ 90% Storage humidity ≤ 95%

Storage humidity ≤ 95% Operating temperature -25°C - +55°C

Operating temperature -25°C - +55°C


1 2 Storage temperature -40°C - +70°C

Storage temperature -40°C - +70°C Reference temperature 23°C± 2°C 1 2 3 4


Terminal 1 & 2: L-in/out
Reference temperature 23°C± 2°C International standard IEC 62053-21 / EN50470-1/3 Terminal 3 & 4: N-in/out
International standard IEC 62053-21 / EN50470-1/3 Accuracy class Class1/Class B

Accuracy class Class1/Class B 8 9 10


Installation category CAT II L-in L-out N-in N-out

Installation category CAT II + COM - Mechanical environment M1

M1
5 6 7 8 9 10
Electromagnetic environment E2
Mechanical environment Dimensions
Electromagnetic environment E2 Degree of pollution 2

Degree of pollution 2 3 4 P rotection against penetration of dust and water IP51(indoor)

P rotection against penetration of dust and water IP51(indoor) N-in N-out


Insulating encased meter of protective class II

Insulating encased meter of protective class II Aititude up to 2000m

Electrostatic discharges 8kV contact / 15kV air gap Electrostatic discharges 8kV contact / 15kV air gap

Electromagnetic HF fields IEC 61000-4-3


Dimensions Electromagnetic HF fields IEC 61000-4-3

Electrical fast transients 4kV Electrical fast transients 4kV


45mm
Surge 4kV Surge 4kV
Height 99mm
Radiated & conducted emissions EN 55022 Width 36mm Radiated & conducted emissions EN 55022
Depth 63mm

MECHANICS MECHANICS
63mm

Din rail dimensions 99x36x63 (WxHxD) DIN 43880 Din rail dimensions 76x100x66 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 100mm
Sealing IP51 (indoor) Sealing IP51 (indoor) Width 76mm
Material self-extinguishing UL94V-0 Depth 66mm
Material self-extinguishing UL94V-0 36
m
m 35mm
99mm

41 Product Catalog EASTRON Product Catalog EASTRON 42


SMART
SMART DIN-RAIL METER
DIN-RAIL

100A MAX. direct load 100A MAX. direct load


7 Module wide
4 Module wide
Active energy measured
SDM320E Active energy measured SDM530A/D/D-2T IEC62053-21 Class 1
SINGLE PHASE 3 WIRE KWH METER
Pulse output THREE PHASE 4 WIRE KWH METER Pulse output
IEC62053-21 Class 1 2 Tariffs available

Description Description
Specification Specification
Model SDM320E Model SDM530D / SDM530D-2T
Nominal voltage(Un)
SDM320 —E—1—1 Nominal voltage(Un) 3x230/400 V ac or 3x127/220 V ac SDM530 —A—1—1
110/220 V ac or220/380V ac
Operational voltage 80%~120% of Un Operational voltage 80%~120% of Un
Insulation capabilities E: Single Phase 3 Wire Insulation capabilities A: Analog Register, kWh
D: LCD Display, kWh
- AC voltage withstand 4KV for 1 minute - AC voltage withstand 4KV for 1 minute
1: Without Backlight D2T: LCD Display, kWh, Double Tariff
- Impulse voltage withstand 6KV-1.2µS - Impulse voltage withstand 6KV-1.2µS
2: With Backlight
Basic current (Ib) 10A Basic current (Ib) 10A 1: Without Backlight
Maximum rated current (Imax) 1: 110V/220V AC Maximum rated current (Imax) 100A 2: With Backlight
100A
2: 220V/380V AC
Operational current range 0.4% Ib-Imax Operational current range 0.4% Ib-Imax
1: 127V/220V
Over current withstand 30 Imax for 0.01s Over current withstand 30 Imax for 0.01s
2: 230V/400V
Operational frequency range 50 or 60Hz Wiring diagrams Operational frequency range 50 or 60Hz
Internal power consumption ≤ 2W/10VA Power consumption per phase ≤ 2W/10VA
Pulse output 1600imp/kWh Pulse output 800imp/kWh
LCD
Wiring diagrams
Display LCD Display
N-in N-out

Max reading 99999.99 kWh Max reading 999999.9 kWh(SDM530D)


999999.99 kWh(SDM530D-2T)
8 7 6 5
230V/2T
Performance criteria 11 10 9 8

Operating humidity ≤ 90% Performance criteria


Storage humidity ≤ 95% Operating humidity ≤ 90% 11 10 9 8

Operating temperature -25°C - +55°C Storage humidity ≤ 95%


SDM530D-2T
1 2 3 4
Storage temperature -40°C - +70°C Operating temperature -25°C - +55°C
Reference temperature 23°C± 2°C Storage temperature -40°C - +70°C 1 2 3 4 5 6 7
International standard IEC 62053-21 / EN50470-1/3 Reference temperature 23°C± 2°C
L1-in L1-out L2-in L2-out
Accuracy class Class1/Class B International standard IEC 62053-21 / EN50470-1/3
9 8
Installation category CAT II Dimensions Accuracy class Class1/Class B L1 -in L1 -out L2 -in L2 -out L3 -in L3 -out N

Mechanical environment M1 Installation category CAT II SDM530A/D


Electromagnetic environment E2 Mechanical environment M1
Dimensions
Degree of pollution 2 Electromagnetic environment E2
P rotection against penetration of dust and water IP51(indoor) Degree of pollution 2
Insulating encased meter of protective class II Insulating encased meter of protective class II
Electrostatic discharges 8kV contact / 15kV air gap Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3 Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV Electrical fast transients 4kV
Surge 4kV Surge 4kV
Radiated & conducted emissions EN 55022 Radiated & conducted emissions EN 55022

65mm
49mm
Mechanics
Mechanics 35
Din rail dimensions 76x100x66 (WxHxD) DIN 43880 10
0m
mm
m
Mounting DIN rail 35mm Din rail dimensions 100x125x65 (WxHxD) DIN 43880 125
mm

Height 100mm Mounting DIN rail 35mm


Sealing IP51 (indoor) Width 76mm
Material self-extinguishing UL94V-0 Depth 66mm Sealing IP51 (indoor) Height 100mm
Material self-extinguishing UL94V-0 Width 125mm
Depth 65mm

43 Product Catalog EASTRON Product Catalog EASTRON 44


SMART
SMART DIN-RAIL METER
DIN-RAIL

100A direct load 100A direct load


4 Module wide 4 Module wide
Measures active energy(kWh)+ power(W) Measures active energy(kWh)+ power(W)
SDM72D/DR/BI Bi-directional measurement SDM72D-M Bi-directional measurement
THREE PHASE 4 WIRE ENERGY METER Resettable energy THREE PHASE 4 WIRE ENERGY METER
MID Resettable energy MID
Pulse output Rs485 Modbus + Pulse output

Specification Description Specification Modbus


Model SDM72D/BR/BI Model SDM72D/BR/BI Bus type RS485(semi-duplex)
Nominal voltage(Un) 3x230/400 V ac SDM72—D—1—1—B Nominal voltage(Un) 3x230/400 V ac Protocol Modbus RTU
Operational voltage 80%~120% of Un D: LCD display, kWh , Pulse output Operational voltage 80%~120% of Un Baud rate 1200/2400/4800/9600bps
DR: “D” + Power measurement and Resettable Energy
Insulation capabilities BI: “DR” + Import and export energy Insulation capabilities Address range 1-247
- AC voltage withstand 4KV for 1 minute - AC voltage withstand 4KV for 1 minute Max. Bus loading 64pcs
- Impulse voltage withstand 6KV-1.2µS 1:110/220V
- Impulse voltage withstand 6KV-1.2µS Communication distance 1000M
2:230/400V
Basic current (Ib) 10A Basic current (Ib) 10A Parity EVEN/ODD/NONE
Maximum rated current (Imax) 100A 1: MID
Maximum rated current (Imax) 100A Data bit 8
2: Non-MID
Operational current range 0.4% Ib-Imax Operational current range 0.4% Ib-Imax Stop bit 1
B:Class 1
Over current withstand 30 Imax for 0.01s C: Class 0.5s Over current withstand 30 Imax for 0.01s
Operational frequency range 50 or 60Hz Operational frequency range 50 or 60Hz Description
Power consumption per phase ≤ 2W/10VA Wiring diagrams Power consumption per phase ≤ 2W/10VA
Pulse output 1000imp/kWh Pulse output 1000imp/kWh
SDM72D-M—1—1—B
Display LCD L1 L2 L3 N Display LCD
Max reading 999999.9 kWh Max reading 999999.9 kWh D-M: Import and export Energy
Terminals 1 & 2 & 3 : L-in and Power measurement;
Rs485 Modbus; Pulse output
Terminal 4: N-in
1 2 3 4
Performance criteria Performance criteria 1:110/220V
Operating humidity ≤ 90% Operating humidity ≤ 90% 2:230/400V

Storage humidity ≤ 95% Storage humidity ≤ 95% 1: MID


2: Non-MID
Operating temperature -25°C - +55°C Operating temperature -25°C - +55°C
B:Class 1
Storage temperature -40°C - +70°C Storage temperature -40°C - +70°C C: Class 0.5s
5 6 7 8
Reference temperature 23°C± 2°C Terminal 5 & 6 & 7 & 8: L-in Reference temperature 23°C± 2°C
Terminal 4: N-out
International standard IEC 62053-21 / EN50470-1/3 International standard IEC 62053-21 / EN50470-1/3 Wiring diagrams
Accuracy class Class1/Class B Accuracy class Class1/Class B
L1 L2 L3 N
Installation category CAT III Installation category CAT III L1 L2 L3 N

Mechanical environment M1 Mechanical environment M1


Dimensions Terminals 1 & 2 & 3 : L-in
Electromagnetic environment E2 Electromagnetic environment E2
Terminal 4: N-in
Degree of pollution 2 m Degree of pollution 2 1 2 3 4
45m
P rotection against penetration of dust and water IP51(indoor) P rotection against penetration of dust and water IP51(indoor)
Insulating encased meter of protective class II Insulating encased meter of protective class II
Aititude up to 2000m Aititude up to 2000m
Electrostatic discharges 8kV contact / 15kV air gap Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3 Electromagnetic HF fields IEC 61000-4-3 5 6 7 8
Terminal 5 & 6 & 7 & 8: L-in
Electrical fast transients 4kV Electrical fast transients 4kV Terminal 4: N-out
Surge 4kV Surge 4kV
Radiated & conducted emissions EN 55022 Radiated & conducted emissions EN 55022 L1 L2 L3 N
m
72 35m
m mm
m 100
Dimensions
Mechanics Mechanics
Din rail dimensions 72x100x66 (WxHxD) DIN 43880 Height 100mm
Width 72mm Din rail dimensions 72x100x66 (WxHxD) DIN 43880
Height 100mm
Mounting DIN rail 35mm Depth 66mm Mounting DIN rail 35mm Width 72mm
Sealing IP51 (indoor) Sealing IP51 (indoor) Depth 66mm
Material self-extinguishing UL94V-0 Material self-extinguishing UL94V-0

45 Product Catalog EASTRON Product Catalog EASTRON 46


SMART
SMART DIN-RAIL METER
DIN-RAIL

CT operated CT operated
4 Module wide 4 Module wide
Measures active energy(kWh)+ power(W) Measures active energy(kWh)+ power(W)
SDM72CT-D/DR/BI Bi-directional measurement
SDM72CT-M Bi-directional measurement
Resettable energy THREE PHASE 4 WIRE ENERGY METER Resettable energy
THREE PHASE 4 WIRE ENERGY METER
Pulse output RS485+Pulse output

Specification Description Specification Modbus


72CT-D/DR/BI Model 72CT-D/DR/BI Bus type RS485(semi-duplex)
Model
3x230/400 V ac Nominal voltage(Un) 3x230/400 V ac Protocol Modbus RTU
Nominal voltage(Un)
SDM72—CT—D—1—B 80%~120% of Un
Operational voltage 80%~120% of Un Operational voltage Baud rate 1200/2400/4800/9600bps
Insulation capabilities
CT: 5A CT operated type Insulation capabilities Address range 1-247
MV: 100mV CT operated type
4KV for 1 minute - AC voltage withstand 4KV for 1 minute Max. Bus loading 64pcs
- AC voltage withstand
D: LCD display, kWh , Pulse output
6KV-1.2µS - Impulse voltage withstand 6KV-1.2µS Communication distance 1000M
- Impulse voltage withstand DR: “D” + Power measurement and Resettable Energy

5A
BI: “DR” + Import and export energy
Basic current (Ib) 5A Parity EVEN/ODD/NONE
Basic current (Ib) DM: “BI” + RS 485 Modbus

6A Maximum rated current (Imax) 6A Data bit 8


Maximum rated current (Imax) 1:110/220V
0.4% Ib-Imax 2:230/400V Operational current range 0.4% Ib-Imax Stop bit 1
Operational current range
20 Imax for 0.01s Over current withstand 20 Imax for 0.01s
Over current withstand B:Class 1

50 or 60Hz
C: Class 0.5s
Operational frequency range 50 or 60Hz
Operational frequency range
≤ 2W/10VA Power consumption per phase ≤ 2W/10VA
Power consumption per phase
Pulse output 1000imp/kWh Pulse output 1000imp/kWh Description
LCD Display LCD
Display
999999.9 kWh Max reading 999999.9 kWh
Max reading
SDM72—CT—D—1—B

CT: 5A CT operated type


Wiring diagrams Performance criteria MV: 100mV CT operated type
Performance criteria
≤90% Operating humidity ≤90% D: LCD display, kWh , Pulse output
Operating humidity DR: “D” + Power measurement and Resettable Energy

≤ 95% Storage humidity ≤ 95% BI: “DR” + Import and export energy
Storage humidity DM: “BI” + RS 485 Modbus
-25°C - +55°C Operating temperature -25°C - +55°C
Operating temperature
1:110/220V
-40°C - +70°C Storage temperature -40°C - +70°C
Storage temperature 2:230/400V

23°C± 2°C Reference temperature 23°C± 2°C


Reference temperature B:Class 1

IEC 62053-21 / EN50470-1/3 International standard IEC 62053-21 / EN50470-1/3 C: Class 0.5s
International standard
Class1/Class B Accuracy class Class1/Class B
Accuracy class
Installation category CAT III Wiring diagrams
Installation category CAT III
M1 Mechanical environment M1
Mechanical environment
E2 Electromagnetic environment E2
Electromagnetic environment RS485
2 Degree of pollution 2 9 10 11 12 13 14
Degree of pollution
P rotection against penetration of dust and water IP51(indoor) G B A
P rotection against penetration of dust and water IP51(indoor)
II Insulating encased meter of protective class II
Insulating encased meter of protective class
Electrostatic discharges 8kV contact / 15kV air gap Dimensions Electrostatic discharges 8kV contact / 15kV air gap

IEC 61000-4-3 Electromagnetic HF fields IEC 61000-4-3


Electromagnetic HF fields
4kV Electrical fast transients 4kV
Electrical fast transients
4kV Surge 4kV
Surge
EN 55022 Radiated & conducted emissions EN 55022
Radiated & conducted emissions

Mechanics Dimensions
Mechanics
Din rail dimensions 100x125x65 (WxHxD) DIN 43880 Din rail dimensions 100x125x65 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 94.5mm
Material self-extinguishing UL94V-0 Width 72mm
Material self-extinguishing UL94V-0
Height 94.5mm Depth 65mm
Width 72mm
Depth 65mm

47 Product Catalog EASTRON Product Catalog EASTRON 48


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 A Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 100mA / 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Measures kWh, kVarh, kW, kVar, kVA, P, F, PF, Hz, dmd, V, A, etc. Max. continuous input overload current 120% of nominal Altitude 3000m
Bi-directional Measurement IMP & EXP Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Energy Information of Each Phase
Total Harmonic Distortion of Voltage and Current Power supply Outputs
2nd~63rd Individual Harmonic Distortion Operating range Self powered (from any of the three phases) Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
RS485 Modbus RTU & Two Pulse Outputs Supply burden < 2W / 10 VA Contact Rating current 2-27mA at 27V DC
Bar Graph for Power Indication Contact Rating voltage 5-27V DC
Three phase self-power supply Accuracy Pulse Width 60 / 100 / 200 ms
Voltage (V) 0.5% of range maximum Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
Backlit LCD Display for Full Viewing Angles
MID Current (A) 0.5% of range maximum Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
Accuracy Class 0.2S /0.5S /1.0
Frequency (Hz) 0.2% of mid-frequency Communications Modbus RTU (RS485)
Plug-in Play solution
Power factor (PF) 1% of unity (0.01) Type 2-wire half duplex
Active power (W) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Reactive power (VAr) 1.0% of range maximum Address 1 to 247
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) Class 0.5S IEC62053-22
Introduction Class 1.0 IEC62053-21 Enclosure
Enclosure Style DIN 96 panel mount
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
The Smart X96 digital smart meter from Eastron is an ideal solution for the measurement and display of all important electrical parameters including Dimensions 96x96x62 mm
THD 2% to 63rd harmonic
harmonic distortion of total and individual, up to 63rd. The meter uses a high definition screen with programmable backlight for high visibility in Panel cut-out 92x92mm
dark area and from all viewing angles. New sector icons shows the percentage of the power load on 3 phases. Modbus RS485 RTU and 2 pulse outputs Panel thickness 1-2 mm
Measured Range
are equipped as standard. Protection rating Ip51 (Indoor)
Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
Material UL 94-VO
Current (A) 5 – 120% of nominal
The Smart X96 and 3-in-1 Current transformers provide a simple and fast installation solutions. With pre-cut wiring looms, the meters and CTs can be Weight 340 g
Frequency (Hz) 45– 66 Hz
easily connected. This solution reduces lot of wiring and installation time, and save wrong wiring troubles. Cable size 0.05mm-4mm stranded wire
Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
Terminals Voltage: Shrouded screw-clamp. Current: RJ12
Energy 8digit, upto 9999999.9 kWh
Power factor 4 quadrant
THD 0 – 40% upto 63rd harmonic

“Plug-in Play Solution”


Current connection cable between INSTALL Dimensions
100mA and the meter. Current connection cable between
5A CT and the meter.
Cable Length up to 5M. A+
B-
G

2P1+
CO
M+

P2+ I1


I2

SMART X96

I3

ESCT-SC
SECT-RJ SECT-SC
32
meters
96mm

Smart X96 91~92mm


SMART X96-1 SMART X96-5

m
96m
70 mm

L1
L2
L3 Daisy connection for power supply. Height 96mm
N Max. 32pcs meters can be connected. 91~92mm Width 96mm
The example shows a wiring in 3p4w network. Plug-in type voltage terminals. 1~2mm Depth 70mm
the meter can also work in 3p3w and 1p2w system.

49 Product Catalog EASTRON Product Catalog EASTRON 50


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 F~J Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 100mA / 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Max. continuous input overload current 120% of nominal Altitude 3000m
● Multi-parameter Measurements
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
●U p to 63 rd THD and IHD
●R S485 Modbus RTU
●E thernet TCP Gateway Power supply Outputs
Operating range Self powered (from any of the three phases)
●M ulti-tariffs Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
Supply burden < 2W / 10 VA
●D igital Input/Output Contact Rating current 2-27mA at 27V DC
●A ccuracy Class 0.5s Contact Rating voltage 5-27V DC
Accuracy
●B ar Graph for Power Indication MID Voltage (V) 0.5% of range maximum
Pulse Width 60 / 100 / 200 ms
Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
●B acklit LCD Display for Full Viewing Angles
Current (A) 0.5% of range maximum Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
●P ush-in Installation and Plug-in Connection Frequency (Hz) 0.2% of mid-frequency Communications Modbus RTU (RS485)
Power factor (PF) 1% of unity (0.01) Type 2-wire half duplex
Active power (W) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Reactive power (VAr) 1.0% of range maximum Address 1 to 247
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) Class 0.5S IEC62053-22
Introduction Class 1.0 IEC62053-21 Enclosure
Enclosure Style DIN 96 panel mount
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
The multifunction energy analyzer SMART X96 F~J series is a top new-generation intelligent panel meter with built-in interfaces provides RS485 Dimensions 96x96x62 mm
THD 2% to 63rd harmonic
Modbus RTU and Ethernet TCP/IP communication. Digital input and outputs are provided for external signal counting and external device control. Panel cut-out 92x92mm
30 type's parameters can be set for alarm. This series is widely used not only in the electricity transmission and power distribution system, but also Panel thickness 1-2 mm
in the power consumption measurement and analysis in LV/MV Intelligent power grid. The Unit can be used as a gateway for Modbus RTU/TCP. Measured Range
Protection rating Ip51 (Indoor)
Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
Material UL 94-VO
SMART X96 measures and displays the characteristics of 1p2w, 3p4w and 3p3w supplies, including voltage, frequency, current, power and active Current (A) 5 – 120% of nominal
Weight 340 g
and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand etc. Energy is measured in terms of kWh, kVArh and kVAh. Frequency (Hz) 45– 66 Hz
Cable size 0.05mm-4mm stranded wire
Maximum demand current can be measured over preset periods of up to 60minutes. The SMART X96 can be configured to work with a wide range Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
Terminals Voltage: Shrouded screw-clamp. Current: RJ12
of CTs and Pts, giving the unit a wide range of operation. Energy 8digit, upto 9999999.9 kWh
Power factor 4 quadrant
THD 0 – 40% upto 63rd harmonic

INSTALL Dimensions
Smart X96 —5—J—2—4—C
1: 100mA
2: 100mV
3: 333mV SMA RT X96

5: 1A & 5A F: Basic version


G: 4DI + 2DO
H: Ethernet TCP Port
I : Ethernet Port + 4DI +2DO
J : RS485-Ethernet gateway + 4DI +2DO 96mm

92mm
2: Aux. AC power supply
3: Aux. DC power supply
1: Single tariff
2: 2 Tariffs
4: 4 Tariffs 96m
m mm
70
B:Class 1 92mm
C: Class 0.5s
D: Class 0.2s
Height 96mm
Width 96mm
1~2mm Depth 70mm

51 Product Catalog EASTRON Product Catalog EASTRON 52


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing

Smart X835 series Nominal input voltage burden


Nominal input current
< 0.2VA per phase
5A
Shock
Vibration
30g in 3 planes
10Hz to 50Hz, IEC 60068-2-6, 2g
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Max. continuous input overload current 120% of nominal Altitude 3000m
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Multi-parameters measured
Auxiliary 85-276V AC 50/60Hz or 120-380V DC
2~63rd individual Harmonic Distortion Supply burden < 2W /10 VA
Support 3P4W, 3P3W, 1P2W system Outputs
Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
CT and PT connected
Accuracy Contact Rating current 2-27mA at 27V DC
Multi tariffs available Voltage (V) 0.5% of range maximum Contact Rating voltage 5-27V DC
Digital output/ Digital input/ Analog output / Pulse output Current (A) 0.5% of range maximum Pulse Width 60 / 100 / 200 ms
Frequency (Hz) 0.2% of mid-frequency Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
RS485 Modbus communication
Power factor (PF) 1% of unity (0.01) Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
Crest factor & Key factor Active power (W) 1.0% of range maximum Communications Modbus RTU (RS485)
Reactive power (VAr) 1.0% of range maximum Type 2-wire half duplex
Apparent power (VA) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Active energy (kWh) 1.0% of range maximum to IEC 62053-21 Address 1 to 247
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
THD 2% to 63rd harmonic
Enclosure
Introduction Measured Range
Enclosure Style
Dimensions
DIN 96 panel mount
96x96x72 mm
Voltage (V) 5 – 120% of nominal (Min 100V – self powered) Panel cut-out 92x92mm
The multifunction energy analyzer SMART X835 series is a new-generation intelligent panel meter, used not only in the electricity transmission
Current (A) 5 – 120% of nominal Panel thickness 1-2 mm
and power distribution system, but also in the power consumption measurement and analysis in high voltage intelligent power grid.
Frequency (Hz) 45 – 66 Hz Protection rating Ip51 (Indoor)
The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, including Power (W, VAr, VA) 5 – 144% of nominal (bi-directional) Material UL 94-VO
voltage, frequency, current, power , active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand, crest factor and key Energy 8 digit, upto 9999999.9 kWh Weight 340 g
factor etc. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In order to 4 quadrant
Power factor Cable size 0.05mm-4mm stranded wire
measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite current input(s)
THD 0 – 40% upto 63rd harmonic
are obtained via current transformers The SMART X835 can be configured to work with a wide range of CTs, giving the unit a wide range of operation.
Built-in interfaces provide pulse and RS485 Modbus RTU outputs. Configuration is password protected.

Wiring diagram
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10

CT CT CT
L1 * *
* L1 * *
Smart X835 —B—1—1—B L2 *
L1 *
* L2 N
L3 * *
P: 2 Pulse outputs * L3 *
N 1-phase 2-wire
3-phase 3-wire
B:RS485 Modbus, 2 Pulse ouptuts 3-phase 4-wire
DIO: 2 Digital Inputs , 2 Digital Outputs, RS485 Modbus Dimensions
AO: 2 Analog Outputs , RS485, 2 Pulse outputs
2 1 2 1
L N G + - + - + - + - A+ B-
1: Single Tariff 11 12 13 17 18 19 20 17 18 19 20 21 22
4: Multi Tariffs aux. power supply SMART X835-P SMART X835-B

2: Aux. AC power supply


2 1
3: Aux. DC power supply Ao1 Ao2 COM + - + - A+ B- Di1 Di2 COM Do11 Do12 Do21 Do22 A+ B-
14 15 16 17 18 19 20 21 22 14 15 16 17 18 19 20 21 22
B:Class 1
C: Class 0.5s SMART X835-AO SMART X835-DIO

m
Height 96mm

m
72
Width 96mm
Depth 72mm

53 Product Catalog EASTRON Product Catalog EASTRON 54


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing

SMARTconnect X835 Nominal input voltage burden


Nominal input current
< 0.2VA per phase
333mV / 5A
Shock
Vibration
30g in 3 planes
10Hz to 50Hz, IEC 60068-2-6, 2g
SMART POWER ANALYZER Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Max. continuous input overload current 120% of nominal Altitude 3000m
Measures kWh, kVarh, kW, kVar, kVA, P, F, PF,Hz, dmd, V, A, etc. Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Operating range Self powered (from any of the three phases)
Bi-directional Measurement IMP & EXP
Supply burden <2W/10 VA
Total Harmonic Distortion of Voltage and Current Outputs
Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
RS485 Modbus RTU & Two Pulse Outputs Accuracy Contact Rating current 2-27mA at 27V DC
Backlit LCD Display Voltage (V) 0.5% of range maximum Contact Rating voltage 5-27V DC
Current (A) 0.5% of range maximum Pulse Width 60 / 100 / 200 ms
Plug-in solution
Frequency (Hz) 0.2% of mid-frequency Pulse rate 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
Power factor (PF) 1% of unity (0.01) Pulsed output relay (non-configurable) 3200IMP/kWh
Active power (W) 1.0% of range maximum Communications Modbus RTU (RS485)
Reactive power (VAr) 1.0% of range maximum Type 2-wire half duplex
Apparent power (VA) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Active energy (kWh) 1.0% of range maximum to IEC 62053-21 Address 1 to 247
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
THD 2%
Enclosure
Enclosure Style DIN 96 panel mount
Introduction Measured Range Dimensions 96x96x62 mm
Voltage (V) 5 – 120% of nominal (Min 100V – self powered) Panel cut-out 92x92mm
The multifunction energy analyzer SMARTConnect X835 series is an economic solution for three phase intelligent panel meter, used not only in Current (A) 5 – 120% of nominal Protection rating Front IP54, Rear IP30
the electricity transmission and power distribution system, but also in the power consumption measurement and analysis in high voltage Frequency (Hz) 44 – 66 Hz Material UL 94-VO
intelligent power grid. 340 g
Power (W, VAr, VA) 5 – 144% of nominal (bi-directional) Weight
Energy 8 digit, upto 9999999.9 kWh Cable size 0.05mm-4mm stranded wire
The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, including
voltage, frequency, current, power , active and reactive energy, imported or exported, THD, Power factor, Max. Demand etc. The meter provides Power factor 4 quadrant Terminals Voltage: Shrouded screw-clamp. Current: RJ12
a Rs485 communication port for remote reading and monitoring. THD 0 – 40% upto 63rd harmonic

Wiring diagram

1 2 3 4 5 6 13 14 15 16 17 18 1 2 3 4 5 6 13 14 15 16 17 18

Smartconnect X835 —CT—B


CT CT
L1 * L1 *
CT: 5A CT input,Multi Parameters, Rs485 Modbus L2
*
* L2
*

*
MV: 333mV CT input, Multi Parameters, Rs485 Modbus L3 *
*
L3 *
*
V: 3 phase voltage (L-N,L-L), Rs485 Modbus N
3-phase 3-wire
A: 3 phase Current , Rs485 Modbus 3-phase 4-wire

W: 3 phase Current , Voltage and Power,Rs485 Modbus

1 2 3 4 5 6 13 14 15 16 17 18
B:Class 1
C: Class 0.5s + - + G B- A+
CT 19 20 21 22 23 24
*
L1 *

N Height 96mm
1-phase 2-wire Width 96mm
Depth 50mm

55 Product Catalog EASTRON Product Catalog EASTRON 56


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing
Nominal input voltage burden < 0.2VA per phase Shock 30g in 3 planes
SMART X72 Nominal input current 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
SMART POWER ANALYZER Max. continuous input overload current 120% of nominal Altitude 3000m
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Mult-parameters measured
RS485 Modbus RTU & two pulse output
Power supply Outputs
Digital input & Digital output Auxiliary 85-276V AC 50/60Hz or 120-380V DC Communications Modbus RTU (RS485)
CT&PT programmable Supply burden < 2W /10 VA Type 2-wire half duplex
THD of Voltage and current Baud rate 2400,4800, 9600, 19200, 38400
Address 1 to 247
Accuracy
Voltage (V) 0.5% of range maximum
Current (A) 0.5% of range maximum Enclosure
Frequency (Hz) 0.2% of mid-frequency DIN 96 panel mount
Enclosure Style
Power factor (PF) 1% of unity (0.01) 96x96x50 mm
Dimensions
Active power (W) 1.0% of range maximum 92x92mm
Panel cut-out
Reactive power (VAr) 1.0% of range maximum Front IP54, Rear IP30
Protection rating
Apparent power (VA) 1.0% of range maximum UL 94-VO
Material
Active energy (kWh) 1.0% of range maximum to IEC 62053-21 300 g
Weight
Introduction Reactive energy (kVArh)
THD of current and voltage
1.0% of range maximum to IEC 62053-24
2%
Cable size 0.05mm-4mm stranded wire
Voltage: Shrouded screw-clamp. Current: RJ12
Terminals

The multifunction energy analyzer SMART X72 series is an intelligent panel meter, used not only in the electricity transmission and power
distribution system, but also in the power consumption measurement and analysis in high voltage intelligent power grid.
Measured Range
The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, including Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
voltage, frequency, current, power , active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand, etc. Energy is Current (A) 5 – 120% of nominal
measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In order to measure energy, Frequency (Hz) 45 – 66 Hz
the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite current input(s) are obtained via
Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
current transformers The SMART X72 can be configured to work with a wide range of CTs, giving the unit a wide range of operation. Built-in
Energy 8 digit, upto 9999999.9 kWh
interfaces provide pulse and RS485 Modbus RTU outputs. Configuration is password protected.
Power factor 4 quadrant
THD 0 – 40% upto 21st harmonic

Wiring diagram

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Smart X72 —CT—B

CT: 5A CT input,Multi Parameters, Rs485 Modbus CT


CT

MV: 333mV CT input, Multi Parameters, Rs485 Modbus L1 *


L1
*
*
*
L2 *
L2
V: 3 phase voltage (L-N,L-L), Rs485 Modbus *
L3 *
L3 *
A: 3 phase Current , Rs485 Modbus * *
N
W: 3 phase Current , Voltage and Power,Rs485 Modbus
3-phase 4-wire 3-phase 3-wire

B:Class 1 L N G
C: Class 0.5s 1 2 3 4 5 6 7 8 9 10
11 12 13
aux. power supply Height 72mm
CT Width 72mm
Do11 Do12 Do11 Do12 COM A+ B-
L1
*
*
Depth 74mm
14 15 16 17 18 19 20
N
1-phase 2-wire

57 Product Catalog EASTRON Product Catalog EASTRON 58


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Specification Specification
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Power consunption
Pm1000 Series 2 times/ second ( instantaneous) Storage temperature
Reference temperature
-40°C~+70°C
23°C~±2°C
voltage: < 1VA / phase
Single Phase System Impedance Electromagnetic environment E2
current: < 0.4VA / phase
Degree of pollution 2
Frequency current : < 20m
High precision measurement of V, A,Hz, W, PF Protection against penetration of dust and water IP51
Auxiliary Power Supplly 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Class 0.5 Working Range AC 220V Electrical fast transient burst lever Class 4
Rated voltage: AC0-600V/DC, 0-1000V Power Consumption : < 4VA

Rated current: 1A / 5A AC, 0~10A DC


Frequenct: 45~65 Hz or DC
Auxiliray power supply: AC/ DC 85V~265V
Dimension optional: 48*96, 72*72, 96*96

Wiring diagram

Introduction
The Eastron PM1000 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor in the grid. It is convenient to install, easy to wire, and simple to maintain, and it is an upgrade product of
various tyes of the pointer header.

72mm

96mm
72m
m mm
45 96mm SIZE 1: 96X96X84mm
SIZE 2: 72X72X45mm

Pm1000 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
W: Power
Cos: PF

48mm
1: 48x96
2: 72x72
96m
3: 96x96 m

mm
E: LED

79
C: LCD
SIZE 3: 96X48X79mm
AC:AC220V
DC: AC/DC85~265V

59 Product Catalog EASTRON Product Catalog EASTRON 60


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Specification Performance
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
Pm1500 Series Power consunption 1.2 times ( Continued), Operating temperature -25°C~+55°C
-40°C~+70°C
2 times/ second ( instantaneous) Storage temperature
Single Phase System 23°C~±2°C
Reference temperature
voltage: < 1VA / phase
Impedance Electromagnetic environment E2
current: < 0.4VA / phase
High precision measurement of V, A,Hz, W, PF etc Degree of pollution 2
Frequency current : < 20m
Class 0.5 Protection against penetration of dust and water IP51
Auxiliary Power Supplly 45~65 Hz or DC Class 4
ESD ( Electro- Static discharge) level
Support for RS485 Modbus RTU communication Working Range AC 220V Class 4
Electrical fast transient burst lever
Support for digital input, output, analog output Power Consumption : < 4VA Electricalsurge Class 4
Communication Modbus RTU Height above sea level ≤2000m
Rated voltage: AC0-600V/DC, 0-1000V
2 wire half duplex Insulation resistance >100Mohm
Type
Rated current: 1A / 5A AC, 0~10A DC 1minute
Baud Rate 1200,2400( default),4800,9600 Warm up
Frequenct: 45~65 Hz or DC
Digital Output 4
Auxiliray power supply: AC/ DC 85V~265V
Analog Output 0/4~20mA or 0-5/10V
Dimension optional: 48*96, 72*72, 96*96

Wiring diagram

Introduction
The Eastron PM1500 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor, kWh etc in the grid. DI / DO and AO is optional. It is convenient to install, easy to wire, and simple to
maintain. Built-in interfaces provides RS485 Modbus RTU communication. Digital input and outputs and Analog output are provided for external
signal counting and external device control.

Pm1500 —A—1—E—A/D
A: Current
B: Voltage
Hz: Frequency
Cos: PF
W: Power
C: V/A/Hz
M: Multi parameters 1: 48x96
2: 72x72
3: 96x96
E: LED
C: LCD
AC:AC220V
DC: AC/DC85~265V

61 Product Catalog EASTRON Product Catalog EASTRON 62


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Specification Specification
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Overload voltage
Storage temperature -40°C~+70°C
Pm3000 Series Power consunption
2 times/ second ( instantaneous)
voltage: < 1VA / phase
Reference temperature 23°C~±2°C
Electromagnetic environment E2
Three Phase System current: < 0.4VA / phase
Degree of pollution 2
Impedance current : < 20m
Protection against penetration of dust and water IP51
High precision measurement of V, A,Hz, W, Var,PF Frequency 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Auxiliary Power Supplly Working Range AC 220V
Class 0.5 Electrical fast transient burst lever Class 4
Power Consumption : < 4VA
Rated voltage: AC0-600V/DC, 0-1000V
Rated current: 1A / 5A AC, 0~10A DC
Frequenct: 45~65 Hz or DC
Auxiliray power supply: AC/ DC 85V~265V
Dimension optional: 48*96, 72*72, 96*96 Wiring diagram

Introduction
The Eastron PM3000 series digital three phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor in the grid. It is convenient to install, easy to wire, and simple to maintain, and it is an upgrade product of
various tyes of the pointer header.

Pm3000 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
W: Power
Var: Reactive Power
Cos: PF
1: 80x80
2: 72x72
3: 96x96
E: LED
C: LCD
AC:AC220V
DC: AC/DC85~265V

63 Product Catalog EASTRON Product Catalog EASTRON 64


SMART
SMART POWER ANALYZER
DIN-RAIL METER

Specification Performance
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Overload voltage
2 times/ second ( instantaneous) Storage temperature -40°C~+70°C
Pm3500 Series Power consunption
voltage: < 1VA / phase Reference temperature 23°C~±2°C
Electromagnetic environment E2
Three Phase System current: < 0.4VA / phase
Degree of pollution 2
Impedance current : < 20m
Protection against penetration of dust and water IP51
High precision measurement of V, A,Hz, W, Var,PF Frequency 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Auxiliary Power Supplly Working Range AC 220V
Class 0.5 Electrical fast transient burst lever Class 4
Power Consumption : < 4VA
Electricalsurge Class 4
Rated voltage: AC0-600V/DC, 0-1000V
Communication Modbus RTU Height above sea level ≤2000m
Rated current: 1A / 5A AC, 0~10A DC Type 2 wire half duplex Insulation resistance >dayu100Mohm

Frequenct: 45~65 Hz or DC Warm up 1minute


Baud Rate 1200,2400( default),4800,9600
Auxiliray power supply: AC/ DC 85V~265V Digital Output 4

Dimension optional: 48*96, 72*72, 96*96 Analog Output 0/4~20mA or 0-5/10V

Wiring diagram

Introduction
The Eastron PM3500 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor, kWh etc in the grid. DI / DO and AO is optional. It is convenient to install, easy to wire, and simple to
maintain. Built-in interfaces provides RS485 Modbus RTU communication. Digital input and outputs and Analog output are provided for external
signal counting and external device control.

Pm3500 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
Cos: PF
W: Power
C: V/A/Hz
M: Multi parameters
1: 80x80
2: 72x72

E: LED
3: 96x96
C: LCD
AC:AC220V
DC: AC/DC85~265V

65 Product Catalog EASTRON Product Catalog EASTRON 66


GATEWAY
SMART / CONVERTOR
DIN-RAIL METER

ESP-2000 SERIES Lsolation Character


Power Lsolation 3KV
Network Interface Serial Interface

Interface RS232/485/422 x 1
Modbus RTU to Modbus TCP Ethernet
10/100 Mbps, Rj45,
2 KV surge protection
RS485/422 Lsolation 2.5KV Baud Rate 1200bps~115200bps

HCMTI 2.5KV/us Check bit: None, Odd, Even


TCP Server, TCP Client,
Convert Between Modbus TCP and Modbus RTU Work UDP/UDP Multicast, TCP Server
Serial Data bit: 5~9; Stop bit: 1,2;
Mode Parameter Flow control: RTS/CTS,DTR/DCR,
RS485/422 ESD Protection 15KV /Client Coexist XON/XOFF
1 Ethernet port and 1,2,4,8 RS232/422/485 Ports
Each RS485 port supports up to 256 nodes Electrical Character Mechanical Character Work Environment

Support DHCP / DNS / HTTP protocols Voltage 18~36VDC,400~600mW Work Temp.


-45~85℃,5~95%RH
Range (can be customized 12V input) Humidity
Easy Hardware setup Size
L x WxH
9.4cmx6.5cmx2.5cm
Storage
Voltage DC Plug or Terminal Temp.
Input -45~165℃,5~95℃RH
Humidity

Introduction
ESP-2000 series is a high performance serial device server and Modbus Gateway product designed by Eastron for lightning resistance ,
anti-eletromagnetic interference and resisting bad environment requirements, is the flagship product on serial device e server.
The Gateway are designed for easy integration of Modbus TCP and RTU networks. With those models, Modbus serial slave devices can
be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.
The ESP-2100, ESP-2200,ESP-2400,ESP2800 offer features that make network integration easy, customizable, and compatible with
any Modbus network.
ESP-2200 ESP-2400 ESP-2800
Parameter: Parameter: Parameter:
Rs232 Interface Rj45interface. qty. 2 Rs232 Interface Db9.qty. 4 Rs232 Interface Db9.qty. 8
Rs485 Interface Terminal, qty. 2 Rs485 Interface Terminal, qty. 4 Rs485 Interface Equip Db9to terminal pinboard, qty. 8

Rs422 Interface Need customized to open, qty. 2 Rs422 Interface 4 Line terminal, qty. 4 Rs422 Interface None

Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 5.4W

Size L x W x H=9.4cmx6.5cmx2.5cm Size L x W x H=9.2cmx19.7cmx2.5cm Size L x W x H=27cmx10.5cmx2.6cm

ESP-2 —100—1

100: 1x RS232/422/485 ports 63(2.48)

197.7 270
200: 2x RS232/422/485 ports 197.7 246
Port1 Port2 Ethernet Ethernet

0 4(0.16)
RS232/422 RS232/422 Uplink 10/100M

400: 4x RS232/422/485 ports

0 6(0.24)

17.9
26 5

800: 8x RS232/485 ports 48 4

07 13.0 7

80(3.15)

6x8=48
95
43

(0.98)

95

88
88
(0.28)

25
11.5

(0.98)
25
Gateway ESP-2200

1: 12V DC aux. power supply 2 Ports Serial Device Server

2: 24 V DC aux. power supply 165 233


Port1 Port2 DC DC
RS485 RS485 9~24V PE 9~24V
- +
+ - + - + -

67 Product Catalog EASTRON Product Catalog EASTRON 68


GATEWAY
SMART / CONVERTOR
DIN-RAIL METER

ESP-4000 SERIES
RS232/422/485 to WIFI ESP-5000 SERIES
RS232/485 to GPRS/3G/4G
Convert Between RS232/422/485 to WIFI
Ethernet Port available Support RS232/485 to GPRS ESP-5100
Each RS485 port supports up to 256 nodes Support RS232/485 to 3G/4G ESP-5307
Support Modbus TCP to RTU. Support RS232/485 to Ethernet
Support IEEE802.11g/b/n
Easy Hardware setup

Introduction Introduction
ESP-4142 and ESP-4144 is Wifi serial device server designed by Eastron, supporting RS232/422/485 to Wifi. It supports Ethernet and
ESP-5 series covers 2G/3G/4G mobile network. It converts serial port RS232/RS485 to GPRS (ESP-5100) ,and to 3G/4G(ESP-5307). ESP-5100 is
Wifi simultaneous access. the host serial software can self-adapt serial parameter, without setting device serial baudrate.
good option for applications which does not ask high speed communication. ESP-5307 is advanced version with fater transmission speed.
The ESP-4000 series is a high performance serial device server and Wifi Gateway product designed by for lightning resistance ,
ESP-5307 supports TD-LTE/FDD-LTE/WCDMA/TD-SCDMA/GSM. An extra Ethernet port is provided, which can be used at same time when
anti-eletromagnetic interference and resisting bad environment requirements. it provides an easy and wireless integration way of
2G/3G/4G is working. P2P connection is also possible.
Modbus TCP and RTU networks. With those models, Modbus serial slave devices can be seamlessly incorporated into an existing
Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.

Parameter: Parameter:
Serial Port Type RS232/RS485 Transmission Rate 1)3G net speed:uplink 5.76Mbps downlink 7.2Mbps.
2)4G net speed:uplink 2Mbps downlink 68Mbps.
Baud Rate 1200~115200bps

Frequency range 900MHZ/1800MHZ,GPRS multi-slot class 10/8,GPRS SIM Card Voltage: 3V,1.8V; Size: Big Card
mobile station class B
Antenna Interface Optional 50Ω/SMA glue stick antenna or sucker antenna
WIFI IEEE802.11b/g
Transmission Rate Serial Port Type RS232/RS485
Downlink Max:85.6kbps;Uplink Max:42.8kbps;
Antenna Stick antenna, sucker antenna
Support PBCCH,Coding schemes CS 1,2,3,4,CSD Serial Parameter Baud Rate:1200~115200bps
up to14.4kbps, USSD, PPP-stack
Interface RS232/485/422 serial port
Power Port Q2.1 outlet, can be customized to power terminal input

Baud Rate 1200bps~115200ps SIM Card Voltage 3V,1.8V Input Voltage 9~24V DC

Network Format 10M/100M self-adapting


Antenna Interface 50Ω/SMA (Female) Current <200mA@9V

Interface Type 2 line Terminal or 5.5mm, inside positive outside negative, Size L×W×H=9.4cm×6.5cm×2.5cm
Power Interface In-positive, out-negative, standard outlet; 2 line terminal
standard power plug (alternative)
Work Temp. Humidity -40~85℃,5~95% RH
Input Voltage 9~48V input, less than 1W
Input Voltage 9~24V DC

Size L x W x H=9.4cmx6.5cmx2.5cm
Current No card or standby in 77mA

Work Temp. & Humidity -45~85℃,5~95%RH Size L×W×H=9.4cm×6.5cm×2.5cm

Work Temp. Humidity -40~85℃,5~95% RH

69 Product Catalog EASTRON Product Catalog EASTRON 70


GATEWAY
SMART / CONVERTOR
DIN-RAIL METER

ESP-7000 SERIES
ESP-6000 SERIES RS 485 to LOR/Wifi/Ethernet
LORA to Ethernet
Support Rs485 to Lora ESP-7100
Support Lora to Ethernet Support Rs485 to Wifi ESP-7110
Support Lora to RS485 Support Rs485 to Ethernet ESP-7120

Introduction Introduction
ESP-6 is a high-performance LoRa gateway that implements RS485 and LoRa, TCP / IP and LoRa-related translation functions. ESP-7 Series is a high-performance converter, to achieve RS485 and LoRa / WIFI / Ethernet conversion function. RS485 port can be connected
As a gateway in LoRa network, ESP-6 adopts LoRa ad hoc network communication mode, and LoRa meter or LoRa converter to the conventional RS485 communication meter, through the built-in processor, to achieve the conversion of the two communications.
can form a perfect LoRa remote meter reading system. LoRa network using MESH wireless Ad Hoc network, while supporting star, ESP-7100 converts RS485 to LoRa; ESP-7110 converts RS485 to Wifi; ESP7120 converts RS485 to Ethernet. With ESP series Gateway, , they can
cluster network, the depth of the leading network routing, automatically select the best route, up to 4 relay hopping; with be used to coperate with LoRa Gateway (ESP-6 series) to form a complete wire / wireless meter reading system.
routing auto-repair feature to achieve seamless new Add or delete devices without manual intervention in routing operations.

Input channel:
Output channel : Input channel: ESP-7100 Output :
Communication mode LoRaMESH or LoRaWan
Output port 1 Ethernet Input port Rs485 Modbus RTU Communication mode LoRaMESH or LoRaWan
Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Interface parameters RJ45,10/100Mbps Baud rate 1200 ~ 38400 bps Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Communication speed 2.93~0.5 kbpsA (Configurable)
Operating mode TCP server Parity bit None/Odd/Even Communication speed 2.93~0.5 kbps (Configurable)
Maximum transmit power 20dBm
Output port 2 RS485 Modbus RTU Stop bit 1/2 bit Maximum transmit power 20dBm
Receiver sensitivity -112dBm/9.6kbps @GFSK
Baud rate 1200 ~ 38400 bps Data bits 8 bit Receiver sensitivity -112dBm/9.6kbps @GFSK
Maximum communication 1.5km (urban road);2.5km (Open area)
Parity None/Odd/Even Max. Bus Load 32pcs Submeters
Maximum communication 1.5km (urban road);2.5km (Open area)
distance Point to point
Stop bit 1/2 bit distance Point to point
Networking mode MESHwireless ad hoc network,up to 4 relay hopping Temperature and humidity parameter:
Data bits 8 bit Networking mode MESHwireless ad hoc network,up to 4 relay hopping
Operating temperature -25 to 55°C
ESP-7110 Output :
Temperature and humidity parameter: Storage temperature -40℃to +70℃
Power supply parameters: WIFI IEEE802.11b/g
Operating temperature -25 to 55°C Humidity range 0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<2.5W Antenna Stick antenna, sucker antenna
Storage temperature -40°Cto +70°C
Maximum input voltage 28VDC Power supply parameters:
Humidity range
ESP-7120 Output :
0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<1.5W
Ethernet 10/100 Mbps, Rj45,2 KV surge protection
Maximum input voltage 28VDC
TCP Server, TCP Client,UDP/UDP Multicast,
Work Mode
TCP Server/Client Coexist

71 Product Catalog EASTRON Product Catalog EASTRON 72


CURRENT
SMART TRANSFORMER
DIN-RAIL METER

Cost effective three-phase moulded case


Cost effective three-phase moulded case
Ratio's ranging from 60/5 to 630/5
ESCT-RJ Series Ratio's ranging from 100A~600A
ESCT-SC Series Plug-in quite connection, 80% labor saving
3-IN-1 CURRENT TRANSFORMER RJ12 socket for quite connection and to eliminate wiring error 3-IN-1 CURRENT TRANSFORMER Lockable terminal for safety
Busbar, DIN-rail and metal feet are supplied as standard Both available for Busbar or DIN Rail mounted

Specification Dimension Specification


Frequency
Dimension
50Hz-60Hz System voltage 720V maximum
Rated current 100A to 630A loads Test voltage 3kV for 1 minute
Rated output 100mA / 333mV ( AC ) System frequency 50Hz or 60Hz
Secondary terminals RJ12 Primary ratings 60A to 630A
Aperture holes centers 35,45mm 21.5
Short circuit thermal current 60 x rated primary current

81
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Overload withstand 1.2 x rated current continuously

26
Phase angle Less than 2 degrees at 50% of rated current Rated dynamic current 2.55 x Ith
Insulation voltage 600 Vac

16
Secondary terminals M4 screw terminals
58.0
Maximum primary voltage 5000 Vac ( Insulated Conductor) Enclosure Flame retardant grad classified UL 94V-0 77.0
Dielectric strength 2.5 KV / I mA / I min Aperture holes centers 25,35,45mm
107.5
Operating temperature -15°C to 60°C Plug-in metal feet for wall or base Mounting ESCT-SC325
Mounting hardware
Operating humidity <85% Bus-bar and DIN-rail
Case material PC / UL 94-VO Compliant with IEC/EN60044-1
Bobbin PBT
Internal structure Epoxy
Compliant with IEC/EN60044/1 Model Ratio (A) Burden ( VA)

14
class:0.5 Class:1.0
5
13 ESCT-SC325 60/1 - 1
ESCT-RJ335 - 86.0
ESCT-SC325 100/1 1.5
Model Rated Amp Output Burden ( VA)
class:0.5 Class:1.0 ESCT-SC325 125/1 1.5 1.5
ESCT-RJ335 60A 100mA 0.25 0.25 ESCT-SC325 150/1 1.5 1.5 ESCT-SC335
ESCT-RJ335 125A 100mA 0.25 0.5 ESCT-SC325 300/1 1.5 1.5
ESCT-RJ335 150A 100mA 0.25 0.5
91
ESCT-RJ335 200A 100mA 0.25 0.5 ESCT-SC335 100/1 - 1.5
31.5
ESCT-RJ335 250A 100mA 0.25 0.5 ESCT-SC335 125/1 - 1.5
-

91.0
31.0
31

ESCT-SC335 150/1 1.5


ESCT-RJ345 250A 100mA 0.25 0.5 ESCT-SC335 160/1 1.5 1.5
16

ESCT-RJ345 300A 100mA 0.25 0.5 ESCT-SC335 200/1 1.5 1.5 31.0
ESCT-RJ345 400A 100mA 0.25 0.5 142 ESCT-SC335 250/1 1.5 1.5 123.0
ESCT-RJ345 500A 100mA 0.25 0.5 142.0
ESCT-RJ345 600A 100mA 0.25 0.5 ESCT-C345 250/1 1.5 1.5 ESCT-SC345
ESCT-RJ345 630A 100mA 0.25 0.5 ESCT-C345 300/1 2.5 2.5
ESCT-C345 400/1 2.5 2.5
ESCT-C345 500/1 2.5 2.5
14

5
600/1 2.5 2.5
ESCT-RJ345 ESCT-C345
13
ESCT-C345 630/1 2.5 2.5

73 Product Catalog EASTRON Product Catalog EASTRON 74


CURRENT
SMART TRANSFORMER
DIN-RAIL METER

Split Core
Cost effective three-phase moulded case
Primary input 100A~5000A
Ratio’s ranging from 60/5 to 630/5
Secondary output 5A / 1A
ESCT-C Series Integrated wire sealable terminal cover ESCT-B Series Two building fixing methods: Base; Busbar mounting
3-IN-1 CURRENT TRANSFORMER Busbar, DIN-rail and metal feet mounting hardware supplied SPLIT CORE CURRENT TRANSFORMER Wide inner window, allowing clamping of big cables or bus-bars
Combined M4 posi /slot screw
Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006

Dimension
Specification Specification
Dimension
Rated current 60A to 630A loads Frequency 50Hz-60Hz
Rated output 5A ( AC ) Rated current 100A to 5000A loads
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Rated output 5A / 1A ( AC )
Phase angle Less than 2 degrees at 50% of rated current Accuracy Class 0.5 or 1 from 20% to 120% of rated current

105
20

30
Insulation voltage 600 Vac S1 S2 S1 S2 S1 S2
Phase angle less than 2 degrees at 50% of rated current
Maximum primary voltage 5000 Vac ( Insulated Conductor) Insulation voltage 600Vac

60
80
Dielectric strength 2.5 KV / I mA / I min Maximum primary voltage 5000Vac ( Insulated Conductor)
14

25
Operating temperature -15°C to 60°C Dielectric strength 2.5 KV / I mA / I min
24
Operating humidity <85% Operating temperature -15°C to 60°C ESCT-B23
Case material PC / UL 94-VO 77 Operating humidity <85%
Bobbin PBT 77 Case material PC / UL 94-VO
Internal structure Epoxy Bobbin PBT
ESCT-C325 Internal structure Epoxy 50

80
145

70
52
32
Model Ratio (A) Burden ( VA) Model Burden ( VA)
class:0.5 Class:1.0 Ratio (A) class:0.5 Class:1.0
ESCT-C325 60/5 - 1 S1 S2 S1 S2 S1 S2 ESCT-B23 100/5 1.5 2.5 114
ESCT-C325 100/5 1.5 1.5 ESCT-B23 150/5 1.5 2.5 ESCT-B58
80

ESCT-C325 125/5 1.5 1.5 20.5 ESCT-B23 200/5 2.5 3.75

38
25
ESCT-C325 150/5 1.5 1.5 35 ESCT-B23 250/5 2.5 5
ESCT-C325 200/5 1.5 ESCT-B23 300/5 5 5
- 105 ESCT-B23 400/5 5 5
105
100/5 - 1.5 250/5 1.5 2.5 80

145
ESCT-C335 ESCT-B58

70

52
32
ESCT-C335 125/5 - 2.5 ESCT-C335 ESCT-B58 300/5 2.5 5
ESCT-C335 150/5 1.5 3.75 ESCT-B58 400/5 3.75 5
ESCT-C335 160/5 1.5 1.5 ESCT-B58 500/5 5 7.5 144
ESCT-C335 200/5 1.5 1.5 ESCT-B58 600/5 5 7.5
ESCT-C335 250/5 1.5 ESCT-B58 750/5 5 10 ESCT-B88
S1 S2 S1 S2 S1 S2

1.5 ESCT-B58 800/5 5 10


ESCT-C345 250/5 2.5 1.5 ESCT-B58 1000/5 7.5 10
38
95

ESCT-C345 300/5 2.5 2.5 30 ESCT-B812 500/5 2.5 5

185
30

120
80
ESCT-C345 400/5 2.5 2.5 ESCT-B812 600/5 2.5 5

70
52
32
45 141
ESCT-C345 500/5 2.5 2.5 ESCT-B812 750/5 5 10
ESCT-C345 600/5 2.5 2.5 ESCT-B812 800/5 5 10
141
ESCT-C345 630/5 2.5 ESCT-C345 ESCT-B812 1000/5 7.5 10 144
ESCT-B812 1200/5 7.5 10
ESCT-B812
ESCT-B812 1250/5 7.5 10
ESCT-B812 1500/5 7.5 10
ESCT-B816 1000/5 10 15
ESCT-B816 1500/5 10 15

245
80

160
ESCT-B816 2000/5 15 20

87
71
50
ESCT-B816 2500/5 20 25
ESCT-B816 3000/5 20 30
ESCT-B816 4000/5 20 30 184
ESCT-B816 5000/5 20 30 ESCT-B816
ESCT-B816 6000/5 20 30
75 Product Catalog EASTRON Product Catalog EASTRON 76
CURRENT
SMART TRANSFORMER
DIN-RAIL METER

Split Core,easy installation Split Core,easy installation


Primary input 100A~600A Primary input 5A~600A
ESCT-T Series Secondary output 5A / 1A ESCT-TU Series Secondary output 333mV / 100mV / 100mA
SPLIT CORE CURRENT TRANSFORMER Safe operation MINI SPLIT CORE CURRENT TRANSFORMER Safe operation
Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006 Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006

Dimension Model Rated Amps Output Accuracy


Specification Specification
SPECIFICATION
Frequency 50-60Hz Frequency 50-60Hz ESCT-TU10 5 0.333 0.5 or 1
Rated current 100A to 600A loads Rated current 5A to 600A loads ESCT-TU10 10 0.333 0.5 or 1
Rated output 1A / 5A (AC) Rated output 333mV/100mV (AC) ESCT-TU10 20 0.333 0.5 or 1
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Accuracy Class 0.5 or 1 from 20% to 120% of rated current ESCT-TU10 50 0.333 0.5 or 1
24.5
Phase angle Less than 2 degrees at 50% of rated current Phase angle less than 2 degrees at 50% of rated current ESCT-TU10 75 0.333 0.5 or 1

65.0
Insulation voltage 600Vac Insulation voltage 600Vac ESCT-TU10 5 0.1 0.5 or 1
Maximum primary voltage 5000Vac (Insulated Conductor) Maximum primary voltage 5000Vac (Insulated Conductor) ESCT-TU10 10 0.1 0.5 or 1
Dielectric strength 2.5KV/1mA/1min Dielectric strength 2.5KV/1mA/1min ESCT-TU10 20 0.1 0.5 or 1
45.0 40.0
Operating temperature -15 °C to 60 °C . Operating temperature -15 °C to 60 °C . ESCT-TU10 50 0.1 0.5 or 1
Operating humidity <85% Operating humidity <85% ESCT-TU10 75 0.1 0.5 or 1
ESCT-T24-1 Case material PC / UL94-V0
Case material PC / UL94-V0
Bobbin PBT Bobbin PBT ESCT-TU16 5 0.333 0.5 or 1
Core Permalloy 81.5
35.7 Core Permalloy ESCT-TU16 10 0.333 0.5 or 1
Internal structure Epoxy Internal structure Epoxy ESCT-TU16 50 0.333 0.5 or 1
Leads UL 1015,Twisted Pair, 22AWG ESCT-TU16 100 0.333 0.5 or 1
ESCT-TU16 150 0.333 0.5 or 1
Model Ratio (A) Burden ( VA) Dimension ESCT-TU16 5 0.1 0.5 or 1
class:0.5 57.0 51.0
Class:1.0
100/1 ESCT-TU16 10 0.1 0.5 or 1
ESCT-T24-1 - 1.5
ESCT-T24-1 150/1 - 1.5 ESCT-T36-1 ESCT-TU16 50 0.1 0.5 or 1

200/1 ESCT-TU16 100 0.1 0.5 or 1


ESCT-T24-1 1.5 2.5 10.0
ESCT-TU16 150 0.1 0.5 or 1

41.0
ESCT-T24-1 250/1 1.5 2.5
ESCT-T24-1 300/1 1.5 2.5 24.5
65.0

ESCT-TU24 10 0.333 0.5 or 1

100/1 ESCT-TU24 50 0.333 0.5 or 1


ESCT-T36-1 - 1.5 24.0 26.5

150/1 - 1.5
ESCT-TU10 ESCT-TU24 100 0.333 0.5 or 1
ESCT-T36-1
200/1 ESCT-TU24 250 0.333 0.5 or 1
ESCT-T36-1 1.5 2.5 45.0 40.0

300/1 16.0 ESCT-TU24 300 0.333 0.5 or 1


ESCT-T36-1 1.5 2.5

45.5
400/1 ESCT-TU24 10 0.1 0.5 or 1
ESCT-T36-1 1.5 2.5
ESCT-T24-5 ESCT-TU24 50 0.1 0.5 or 1
ESCT-T36-1 500/1 2.5 3.75
600/1 ESCT-TU24 100 0.1 0.5 or 1
ESCT-T36-1 2.5 5
29.0 31.5 ESCT-TU24 250 0.1 0.5 or 1
35.7
ESCT-TU16 ESCT-TU24 300 0.1 0.5 or 1
81.5

ESCT-T24-5 100/5 - 1.5


ESCT-T24-5 150/5 - 1.5
200/5 ESCT-TU36 20 0.333 0.5 or 1
ESCT-T24-5 1.5 2.5 24.5

65.0
250/5 ESCT-TU36 100 0.333 0.5 or 1
ESCT-T24-5 1.5 2.5
57.0 51.0
300/5 ESCT-TU36 250 0.333 0.5 or 1
ESCT-T24-5 1.5 2.5
ESCT-TU36 400 0.333 0.5 or 1
ESCT-T36-5
100/5 45.0 40.0 ESCT-TU36 600 0.333 0.5 or 1
ESCT-T36-5 - 1.5
ESCT-T36-5 150/5 - 1.5 ESCT-TU24 ESCT-TU36 20 0.1 0.5 or 1

200/5 ESCT-TU36 100 0.1 0.5 or 1


ESCT-T36-5 1.5 2.5
300/5
35.7 ESCT-TU36 250 0.1 0.5 or 1
ESCT-T36-5 1.5 2.5
81.5

400/5 ESCT-TU36 400 0.1 0.5 or 1


ESCT-T36-5 1.5 2.5
500/5 ESCT-TU36 600 0.1 0.5 or 1
ESCT-T36-5 2.5 3.75
ESCT-T36-5 600/5 2.5 5
57.0 51.0
ESCT-TU36
77 Product Catalog EASTRON Product Catalog EASTRON 78
CURRENT
SMART TRANSFORMER
DIN-RAIL METER

Flexible and light weights


Split Core,easy installation
Easy & quick installation in tight spaces
Primary input 5A~3000A
No danger from open-circuited secondary
ESCT-U Series Secondary output 333mV ESCT-RC No core saturation or damage if overloaded
Wide inner window, allowing clamping of big cables excellent linearity
SPLIT CORE CURRENT TRANSFORMER FLEXIBLE ROGOWSKI COIL CURRENT SENSOR
Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006 Multi- size are available
Single phase and three phase are available

Dimension
Specification
Specification
Frequency 50-60Hz Wiring diagram
Current Range 10A to 100kA
Rated current 5A to 3000A loads
Rated output 333mV (AC) Rated output 0.333Vac at rated current with Integrator,
Accuracy ±1% from 20% to 120% of rated current 100mV/per 1000A @ 50Hz without integrator
Phase angle less than 2 degrees at 50% of rated current Accuracy ±1% from 5% to 120% of rated current with
Insulation voltage 600Vac integrator(45-65Hz) ESCT-RC-060-100A/0.333V output-
100Aac to 0.333Vac@50/60Hz output+

Maximum primary voltage 5000Vac (Insulated Conductor) Phase Angle ≤±1°5% to 120% from 5% to 120% of rated current Power supply 9vdc power-
Power+
Dielectric strength 2.5KV/1mA/1min Linear 0.5%
Operating temperature -15 °C to 60 °C . Frequency 1Hz-1MHz ,50/60 Hz nominal CT 1 CT 2 CT 3
CURRENT INPUTS

Operating humidity <85% ESCT-U75 Work Voltage 600V

+9VDC
GND

220VAC
Case material PC / UL94-V0 Power supply 7-30VDC (9 Vdc,12 Vdc recommended ) Powersupply
Electricity Meter

Bobbin PBT Coil Diameter 10.5mm,12mm or as customer order


Core Permalloy Window size 10mm,15mm or as per customer ordered
Internal structure Epoxy Wire lead 1 meter sheath cable or as customers order Dimension
Leads UL 1015,Twisted Pair, 22AWG Withstand Voltage 3000V
Operating temperature -25°C-+70°C
Model Rated Amps Output Accuracy IP class IP65 Col Diameier
φ10. 5mm
ESCT-U75 5 0.333V 1 Certification CE recognized. RoHS Compliant
ESCT-U75 10 0.333V 1
ESCT-U125 Widow Size
Wire Lead Length
ESCT-U75 50 0.333V 1
ESCT-U75 75 0.333V 1 Model Rated Amps Window Size Coil Length

ESCT-U75 100 0.333V 1 ESCT-RC060-100A/0.333V 100/5 60mm


ESCT-U75 125 0.333V 1 ESCT-RC076-200A/0.333V 200/5 76mm
ESCT-U75 150 0.333V 1 400/5 90mm Extemal Diameter
ESCT-RC090-400A/0.333V
ESCT-U75 200 0.333V 1 800/5 100mm
ESCT-RC100-800A/0.333V
ESCT-U125 50 0.333V 1
ESCT-RC150-1000A/0.333V 1000/5 150mm
ESCT-U125 100 0.333V 1
ESCT-RC160-1200A/0.333V 1200/5 160mm
ESCT-U125 200 0.333V 1
ESCT-U200 ESCT-RC190-3000A/0.333V 3000/5 190mm
ESCT-U125 250 0.333V 1
ESCT-RC200-5000A/0.333V 5000/5 200mm
ESCT-U125 4 00 0.333V 1
ESCT-RC300-6000A/0.333V 6000/5 300mm
ESCT-U125 600 0.333V 1
ESCT-U125 630 0.333V 1
ESCT-3RC060-100A/0.333V 100/5 60mm
ESCT-U200 100 0.333V 1
ESCT-3RC076-200A/0.333V 200/5 76mm
ESCT-U200 125 0.333V 1 ESCT-3RC
ESCT-3RC090-400A/0.333V 400/5 90mm
ESCT-U200 250 0.333V 1
ESCT-3RC100-800A/0.333V 800/5 100mm
ESCT-U200 400 0.333V 1
630 0.333V 1 ESCT-3RC150-1000A/0.333V 1000/5 150mm
ESCT-U200
800 0.333V 1 ESCT-U250 ESCT-3RC160-1200A/0.333V 1200/5 160mm
ESCT-U200
ESCT-U200 1000 0.333V 1 ESCT-3RC190-3000A/0.333V 3000/5 190mm
ESCT-U200 2000 0.333V 1 ESCT-3RC200-5000A/0.333V 5000/5 200mm
ESCT-U300 400 0.333V 1 ESCT-3RC300-6000A/0.333V 6000/5 300mm
ESCT-U300 800 0.333V 1
ESCT-U300 1000 0.333V 1
ESCT-U300 1500 0.333V 1
ESCT-U300 2500 0.333V 1
ESCT-U300 3000 0.333V 1
ESCT-U300
79 Product Catalog EASTRON Product Catalog EASTRON 80
CURRENT
SMART TRANSFORMER
DIN-RAIL METER

Two built in fixing methods: 1 side base; Busbar mounting


Built in hinged terminal cover Two built in fixing methods: 1 side base; Busbar mounting
Built in transparent cover for name plate ESCT-DM Series
ESCT-ABO Series Wide range accuracy (3,1,0.5,0.5s, 0.2,0.2s)
Built in hinged terminal cover
SOLID CORE CURRENT TRANSFORMER Primary current from 50A to 3000A SOLID CORE CURRENT TRANSFORMER Primary current from 15A to 300A

Specification Introduction
Specification Introduction
Rated Frequency 50Hz-60Hz
ESCT-ABO perfect designed plastic case current transformer, advanced Rated Frequency 50Hz-60Hz
Rated current 5A to 5000A loads
snap on body, high accuracy ( up to Class 0.2S), humanization transparent ESCT-DM is world famous MINI design plastic case current transformer,
Rated output 5A, 1A, 0.5A, 0.25A, 0.1A Rated current 15A to 300A loads
cover and lead seal hole design makes the CT very easy to identify after snap on body, be wildly used in generators. It is available for connecting
Accuracy ±1% from 20% to 120% of rated current Rated test voltage 3kV AC ( 1min)
long term use and perfect anti-stealing electricity. Rated short-time thermal current (Ith) 60In with cable, and also available for connecting with Busbas. Its primary
Rated short-time thermal current (Ith) 60In
Rated voltage (Um) 0.72Kv AC. currents between 15A~300A with 5A or 1A secondaries with up to
Rated voltage (Um) 1.2 In
-10°C~50°C Dimension Rated output 5A or 1A Class1.0 accuracy Performance.
Operating temperature
Housing self-extinguishing class VO Rated voltage (Um) 1.2 In

Standard IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006 Operating temperature -10°C~50°C


Dimension
Housing self-extinguishing class VO

Model Ratio(A) Burden ( VA) Safety factor Fs5


class:0.5 Class:1.0
Standard IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006
ESCT-ABO-30 50/5 1.5 2.5
ESCT-ABO-30 60/5 1.5 2.5
ESCT-ABO-30 75/5 2.5 3.75
Model Rated Amps Burden(VA)/Class 1.0
ESCT-ABO-30 100/5 3.75 5
ESCT-DM-20/30 50/5 1
ESCT-ABO-30 150/5 5 5
ABO-30 ESCT-DM-20/30 60/5 1.25
ESCT-ABO-30 200/5 5 5
ESCT-DM-20/30 75/5 1.5
ESCT-ABO-30 250/5 5 5
ESCT-DM-20/30 80/5 1.5
ESCT-ABO-30 300/5 5 5
ESCT-DM-20/30 100/5 2.5
ESCT-ABO-40 75/5 1.5 1.5
ESCT-DM-20/30 120/5 2.5
ESCT-ABO-40 80/5 1.5 1.5
ESCT-DM-20/30 150/5 2.5
ESCT-ABO-40 100/5 2.5 2.5
ESCT-DM-20/30 200/5 3.75
ESCT-ABO-40 150/5 3.75 5
ESCT-DM-20/30 250/5 3.75
ESCT-ABO-40 200/5 5 5
ESCT-DM-20/30 300/5 3.75
ESCT-ABO-40 250/5 5 5 ABO-40
ESCT-ABO-40 300/5 5 5
ESCT-DM-20/35 50/5 -
ESCT-ABO-40 400/5 5 5
ESCT-DM-20/35 60/5 -
ESCT-ABO-40 500/5 5 5
ESCT-DM-20/35 75/5 1.5
ESCT-ABO-60 200/5 5 5
ESCT-DM-20/35 80/5 1.5
ESCT-ABO-60 250/5 5 5
ESCT-DM-20/35 100/5 2.5
ESCT-ABO-60 300/5 5 5
ESCT-DM-20/35 120/5 2.5
ESCT-ABO-60 400/5 5 5
ESCT-DM-20/35 150/5 2.5
ESCT-ABO-60 500/5 5 5 ABO-60
ESCT-DM-20/35 200/5 2.5
ESCT-ABO-60 600/5 5 10
ESCT-DM-20/35 250/5 3.75
ESCT-ABO-60 750/5 5 10
ESCT-DM-20/35 300/5 3.75
ESCT-ABO-60 800/5 5 10
1000/5 5 10
DM-20/30 DM-20/35
ESCT-ABO-60
ESCT-ABO-100 800/5 5 10
ESCT-ABO-100 1000/5 5 10
ESCT-ABO-100 1200/5 7.5 10
ESCT-ABO-100 1500/5 7.5 10
ABO-100
ESCT-ABO-100 1600/5 7.5 10
ESCT-ABO-100 2000/5 10 15
ESCT-ABO-100 2500/5 10 15
ESCT-ABO-100 3000/5 10 15

81 Product Catalog EASTRON Product Catalog EASTRON 82


TIME RELAY
SMART DIN-RAIL METER

Microcontroller based Digital time switch with astronomical program


24 operating modes 3 year power reserve(lithium battery).
LCD display operating modes,set delay and operating time Sealable cover of the front panel, easy setting by 4 keys.
Time ranges:0-9999s,0-9999min Automatic summer/winter time switchover
AC/DC 24-240V supply voltage LCD display,Holiday mode.
t1
OFFStart

ESRD-TMS1/S2 2 independent NO contacts, controlled by different operating modes


Backlighted LCD display
t1
OFFStart

ESRD-TPA1 Single channel


Automatic transfer of weekdays
MULTIFUNCTION TIME RELAY Easy setting by keys SLINGLE CHANNEL ASTRONOMICAL 220-240V AC input supply.
2 module Din rail mounting Double-modules, mounted on TH-35 rail.

Description Description
Specification Panel Symbol legend
Output relay ON Specification Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday
Output relay OFF
Supply terminals A1,A2 Supply terminals A1-A2 C1 Channel 1
Output relay 1
Pulse terminal S Rated voltage AC220-240V Relay status: Activate
Output relay 2
Rated frequency 50/60Hz Deactivate
Supply voltage AC/DC 24-240V ONStart SET Parameters setting
Automatic mode
min
ONStart Starting with ON
Power consumption 1W
Rated frequency 50/60Hz t
Manual mode
OFFStart Starting with OFF
Supply volltage tolerance ±10%
Time range 0~9999s, 0~9999min 1 Holiday mode
Time impulse release by rising edge Number of channels
Repetition accuracy max.±3s/24h 25 ºC Time impulse release by falling edge Program astronomical
Sunrise

Data readout Back-lighted LCD display Sunset


min Set time: minute Mode of work manual, automatic, holiday
MENU OK Menu ok Winter time
Data storage 10 years sec Set time: second Summer/winter time off, automatic changes
C1 Summer time
Output contacts 1 C/O +1 NO T Time delay T Time tolerance ≤1s/day at 20°C
Prog Program setting
Current rating 8A/ AC1 T1 Time delay T1 Power reserve 3 year
T2 Time delay T2 Data readout LCD display
Contacts capacity AC-15:2A Keys start Menu ○ Enter main menu Ok
Starting with S pulse Number of contacts 1 C/O ○ Confirm selection
Insulation voltage 250V ○ Back to main menu
MENU ○ Enter configuration menu OK Current of contacts 16A/250V AC1
Protection degree IP20 ○ Confirm settings ○ Select menu ○ Select menu
○ Exit configuration menu Switching capacity 4000VA/AC,384W/DC
○ Increase a numerical value ○ Decrease a numerical value
Pollution degree 3 Electrical life 10
6

Electrical life 10 5 ○ Select menu ○ Select menu 5


Mechanical life 10
○ Digit + ○ Digit -
Mechanical life 10 6
Rated insulation voltage ○ C1 manual operation
○ Display menu selection ○ Display menu selection 250V C1

Altitude ≤2000m Protection degree IP20

-5ºC~+40ºC
Wiring diagrams Pollution degree 3
Ambient temperature Wiring diagrams
-10ºC~+50ºC L Altitude ≤2000m
Storage temperature
0.5mm~1mm
2 2 N Ambient temperature -30°C~55°C
Wire size
Permissable relative humidity ≤50%(40°C,without condensation)
Torque 0.5Nm A1
Storage temperature -35°C~70°C
Mounting TH-35 DIN-Rail Wire size 2 2
A1 15
1mm ~ 4mm
A1 15 25
25 28 A1 A2
Tightening torque 0.5Nm
24-240V
50/60Hz Mounting TH-35 Rail(EN60715)
Front-face panel Dimensions 90*36*64mm Menu Ok

Standard IEC60947-1/IEC60947-2-7
S A2 18 16 28 C1
A2 18 16 18 15 16 A2
Front-face panel
Relay 2 Output contact Supply terminals MENU OK

:DD-MM-YY, 23th.September.2013

18 15 16 S N
Supply terminal L L
25 28 A1 A2 24-240V
Dimensions
50/60Hz
Dimensions
LCD display
OFFStart
A1
220-240V
t1 50/60Hz L
25 28 A1 A2
24-240V
50/60Hz

1 LCD display

35

45
C1
Keys

90
MENU OK
35

45

90

Menu ok

Control keys
MENU OK Menu Ok
C1
18 15 16 S 18 15 16 N

18 15 16 S C1 26
18 15 16 A2 44
Relay 1 Output contact Pulse terminals
26 60
36
44 65
Output - channel 1 Supply terminal N
60 36
65

83 Product Catalog EASTRON Product Catalog EASTRON 84


TIME RELAY
SMART DIN-RAIL METER

Digital time switch with weekly program


10 year power reserve(lithium battery)
Sealable cover of the front panel, easy setting by 4 keys Modular design, 36mm wide housing.
Sensitivity adjustment from 2 to100 lux
Automatic summer/winter time switchover
Eternal light sensor included in delivery
Back-lighted LCD display,Holiday mode Fixed switching on and off delay
t1
OFFStart

ESRD-TPW1/2 Double channels ESRD-ST1 LED indication for power supply and relay status
DOUBLE CHANNEL DIGITAL WEEKLY Automatic transfer of weekdays DIN Rail mounting
24-264V AC/DC input supply
TWILIGHT SWITCH
Double-module, mounted on TH-35 rail

Function diagram
Specification Description
Specification
Supply terminals A1-A2 Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday
Rated control voltage AC220V
Ambient light intensity

Rated voltage AC220-240V Hystersis

Rated frequency C1 Channel 1 Frequency 50/60Hz


50/60Hz Lux setting value

Power consumption 2W C2 Channel 2 Sensitivity threshold 2~100lux adjustable


Supply volltage tolerance ±10% Relay status
Switch-on delay 2-5s
LED:U

Number of channels Double channels Automatic mode


Switch-off delay 10-15s LED:
Number of programs 100 Manual mode tOFF
tON
Program weekly program, daily program Holiday mode Hysteresis
(switching off/on ratio) 1.20
Operating modes manual, automatic, holiday Winter time
Summer/winter time off, automatic changes Summer time Output contact 1NO
Menu Ok Wiring diagrams
Time tolerance ≤1s/day at 25°C C1 C2 Prog Program setting Current rating 25A/250V AC1
Power reserve 10 year
Incandescent lamp load 3000 W L
Data readout LCD display with backlight
Number of contacts Halogen lamp load 3000 W N
2 C/O Menu ○ Enter main menu Ok
Current of contacts 16A/250V AC1 ○ Back to main menu ○ Confirm selection Fluorescent lamp load
(compensated) 1000 W
Switching capacity 4000VA/AC1,384W/DC
6 ○ Select menu ○ Select menu Fluorescent lamp load
Mechanical life 10 ○ Increase a numerical value ○ Decrease a numerical value (uncompensated) 1300 W
Electrical life 10
5 C L N
220V

ok Protection degree Terminal: IP20, Sensor: IP65 50/60Hz

Rated insulation voltage 250V ○C1 manual operation ○C2 manual operation
C1 C2
Protection degree IP20 Ambient temperature -25ºC~+40ºC LIGHT DEPENDENT RELAY
Un:AC220V 50/60Hz
U
L 25A AC1

Pollution degree 3
Altitude ≤2000m Wiring diagrams
B1
Ambient temperature -20°C~55°C Front-face panel B2
Lux
Permissable relative humidity ≤50%(40°C,without condensation) ESRD-ST1

28 25 26 A1
Storage temperature -30°C~70°C A1
C2 N C B1 B2
Output contact Supply terminal
Wire size 1mm ~ 4mm
2 2
A1 15
Tightening torque 0.5Nm A1 15 25
Mounting TH-35 Rail(EN60715)
Menu ok

Dimensions 90*36*64mm Menu Ok

C L N ST110
C1
220V
Standard IEC60947-1/IEC60947-2-7 A2 18 16
C1 18 15 16 A2 50/60Hz
Dimensions
18 15 16 A2 A2 18 16 28 26 Supply indication (yellow)
Output indication(red)
Front-face panel TWILIGHT SWITCH
Un:AC220V 50/60Hz
25A AC1
:DD-MM-YY, 23th.September.2013 N Sensitivity adjustment
N L1
L
C L N
L2 220V
Output - channel 2 Supply terminal A1 50/60Hz

ESRD-TPW1 ESRD-TPW2 LIGHT DEPENDENT RELAY U

Dimensions ESRD-ST1 Un:AC220V 50/60Hz

35
25A AC1

45

90
28 25 26 A1 220-240V
B1 B2
C2 50/60Hz

28 25 26 A1
ESRD-ST1
C2
1 LCD display
C1 Sensor input terminal
C2 B1 B2
35

45

1. Connect the sensor ST110.


90

Control keys 2. Set the sensitivity.


Menu ok Menu ok 26
3. When the strength of light goes below set sensitivity value, output
indication LED lights up and the delay begins. After the switch on 44
C1 36
C1 delay, switch energizes its contacts. Delay can avoid any command 60
18 15 16 A2
18 15 16 A2 caused by temporary illumination or headlights
65
When the strength of light goes above the hysteresis value, output
26
indication LED goes out and the delay begins. After the switch off
44 delay, switch de-energizes its contacts.
Output - channel 1 Supply terminal A2 60 36
65
Hysteresis= 1/4* set sensitivity value

85 Product Catalog EASTRON Product Catalog EASTRON 86


TIME RELAY
SMART DIN-RAIL METER

Microcontroller based
Microcontroller based Modular design,18mm wide housing
Modular design, 18mm wide housing
Possibility of 3 wire or 4 wire connection
10 operating modes
10 time ranges(1s,10s,1m,10m,1h,10h,1d,10d,ON,OFF) ON,OFF,AUTO three operation modes
ESRS-TM11/12/14/23 1 changeover contact ESRD-TSL Series Repetition accuracy<0.2%
MULTIFUNCTION TIME RELAY LED indication for power supply and relay status LCD indication for relay status
DIN-Rail mounting STAIRCASE LIGHTING TIME
DIN-Rail mounting

Description Wiring diagrams


1h 10h 1h 10h
Specification 10m
1m
1d
10d
10m
1m
1d
10d
Specification
10s ON 0.1-1s 10s ON 1-10s
Models ESRS-TM11/14/23 ESRS-TM12 1s OFF 1s OFF
Rated supply voltage AC230VAC,50/60Hz
Supply terminals A1,A2 A1,A2,A3 10m
1h 10h
1d 10m
1h 10h
1d Type of contact 1NO(AgNi)
1m 10d 1m 10d
Pulse terminal S 10s ON 0.1-10min 10s ON 1-10min Rated current(lth) 10A
1s OFF 1s OFF
Power consumption ≤1.5VA
A1-A2: AC 220V 1h 10h 1h 10h
Supply voltage AC 220V
10m 1d 10m 1d
Incandescent lamp load
A3-A2: AC/DC 24V 1m 10d 1m 10d 2000W 3 wire 4 wire
10s ON 0.1-1h 10s ON 1-10h
1s OFF 1s OFF Fluorescent lamp load,leat-lag circuit 1000W
Rated frequency 50/60Hz Example of application
10m
1h 10h
1d 10m
1h 10h
1d Fluorescent lamp load,inductive-capacitive 1000W
Time range 0.1s-10days 1m 10d 1m 10d
3 wire connection
10s ON 0.1-1days 10s ON 1-10days Fluorescent lamp load,parallel compensated 650W
Setting accuracy <5% 1s OFF 1s OFF

1h 10h 1h 10h
Inductive load,cos$=0.6@230V 650W
Repetition accuracy <0.2% 10m 1d 10m 1d
1m 10d
ON
1m 10d
OFF
Mechanical life 10 5
10s ON 10s ON
Output contacts 1 C/O 6
1s OFF 1s OFF Electrical life 10
Current rating 8A /AC1 Time range
0.5 0.6
0.5-20m
1d T1
1h 10h
Contacts capacity AC-15: 2A 10m
1m 0.3
0.4 0.7
0.8 Time adjustment: Setting accuracy ≤5%
10d
10s ON T 0.2 0.9 ×T
Insulation voltage 250V 1s OFF
0.1 1 t=10m x 0.3 = 3 min Repetition accuracy ≤0.2%
Protection degree IP20 Maximum load of illuminated switch 50mA
1h 10h 0.5 0.6
10m 1d T2 0.4 0.7
Pollution degree 3 1m 10d 0.3 0.8 Time adjustment: Reset time ≥200ms
10s ON T 0.2 0.9 ×T

Electrical life 10
5
1s OFF
0.1 1 t=1d x 0.7 = 0.7day Altitude ≤2000m
Mechanical life 10 6 Protection degree IP20
Altitude ≤2000m Wiring diagrams Pollution degree 3
A1 15 A1 15 25 Ambient temperature -5°C~+40°C 4 wire connection
Ambient temperature -5ºC~+40ºC A1 A3 15

Storage temperature Storage temperature -25°C~+75°C


-10ºC~+50ºC
2 2
Wire size 0.5mm ~1mm
Torque 0.5Nm S A2 18 16 S A2 18 16 S A2 18 16 28 26 Front-face panel
L L L
N N N
Mounting TH-35 DIN-Rail

A1 S A2 A1 S A2 AC/DC 24V A1 S A2
Time setting
Front-face panel
A3
Output indication LED(red)
Supply terminals A1,A2

A1 S A2
ESRS-TM11
28 25 26 Function selecting
Supply terminals A3
Pulse terminal A3 18 15 16 18 15 16
18 15 16
ESRS-TM11/14 ESRS-TM12 Dimensions
ESRS-TM23
Supply indication(green) RS-TSL
U
Dimensions
Multi-function
output indication(red)
Functions setting
C
D
E F
G
H
A1 S A2
FUNCTION DIAGRAM
B I FUNC A3
Time setting A J
1h 10h
10m 1d
1m 10d
T U

85.6
10s ON Multi-function

Fine time setting 1s OFF

45
.5 .6
.4 .7 D
E F
G
.3 .8 C H
44.5

B I FUNC
.2 .9 ×T A J
90

1h 10h
10m 1d
.1 1 1m 10d
10s ON T

ESRS-TM11 1s
0.4
0.5 0.6
OFF
0.7
0.3 0.8
0.2 0.9 ×T ESRS-TSL
0.1 1

ESRS-TM12

30
18 15 16 49
18
18 15 16 60 65
Output contact
17.8
65

87 Product Catalog EASTRON Product Catalog EASTRON 88