Sie sind auf Seite 1von 8

SIGNAL LIST FOR RELAYS FOR 33kV INCOMER FEEDER

A) List of Digitial Inputs:


SL. No Signal Description Type of Signal Remarks
1 Breaker ON / OFF Digital Input
2 Breaker Trip Digital Input
3 86 Optd. Digital Input
4 TC -1 Healthy Digital Input
5 TC -2 Healthy Digital Input
6 Bus PT Supply Fail Digital Input
7 EMPB Optd. Digital Input
8 Breaker Spring Charged Digital Input
Local Remote Swicth in Local Digital Input
9 Mode
Local Remote Swicth in Remote Digital Input
10 Mode
11 DC Supply Healthy Digital Input
12 Line Isolator ON/OFF Digital Input
13 Feeder Isolator - 1 ON/OFF Digital Input
14 Bus Isolator ON/OFF Digital Input
15 Line Isolator E/s ON/OFF Digital Input
16 Adjacent feeder -2 relay fail Digital Input

1 Feeder Isolator - 2 ON/OFF Goose from 2nd I/C Relay

2 Bus Isolator ON/OFF Goose to 2nd I/C Relay

SIGNAL LIST FOR RELAYS FOR 33kV INCOMER FEEDER


A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks

TC Healthy for Indication &


1 TCH -1 Healthy Digital Output TC -Unhealthy for
annunciation

2 TCH -2 Healthy Digital Output For Trip & Annuciation

3 All protection trip to 86 relay Digital Output For Trip & Annuciation
4
Over current trip (Directional + Digital Output For Trip & Annuciation
Non - directional)

5
Earth fault trip (Directional + Digital Output For Trip & Annuciation
Non - directional)

6 U/F & O/F Trip Digital Output For Trip & Annuciation

7
Breaker Close Command from Digital Output
Relay

8
Breaker OFF Command from Digital Output
Relay
Annunication + Adjacent
9 Feeder Protection Relay Fail Digital Output
relay input
10 Close Permissive from Relay Digital Output
SIGNAL LIST FOR RELAYS FOR 11kV INCOMER FEEDER
A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks
1 Breaker ON / OFF Digital Input
2 Breaker Trip Digital Input
3 86 Optd. Digital Input
4 TC -1 Healthy Digital Input
5 TC -2 Healthy Digital Input
6 Bus PT Supply Fail Digital Input
7 EMPB Optd. Digital Input
8 Breaker Spring Charged Digital Input
Local Remote Swicth in Local Digital Input
9 Mode
Local Remote Swicth in Remote Digital Input
10 Mode
11 DC Supply Healthy Digital Input
12 Feeder Isolator - 1 ON/OFF Digital Input
13 Bus Isolator ON/OFF Digital Input
14 Adjacent feeder -2 relay fail Digital Input
15 Spare Digital Input
16 Spare Digital Input

1 Feeder Isolator - 2 ON/OFF Goose from 2nd I/C Relay

2 Bus Isolator ON/OFF Goose to 2nd I/C Relay

SIGNAL LIST FOR RELAYS FOR 11kV INCOMER FEEDER


A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks

TC Healthy for
Indication & TC
1 TCH -1 Healthy Digital Output -Unhealthy for
annunciation

For Trip &


2 TCH -2 Healthy Digital Output Annuciation
For Trip &
3 All protection trip to 86 relay Digital Output Annuciation
For Trip &
4 Over current trip Digital Output Annuciation
For Trip &
5 Earth fault trip Digital Output Annuciation
For Trip &
6 U/F & O/F Trip Digital Output Annuciation

7
Breaker Close Command from Digital Output
Relay

8
Breaker OFF Command from Digital Output
Relay
Annunication +
9 Feeder Protection Relay Fail Digital Output Adjacent relay
input
10 Close Permissive from Relay Digital Output
SIGNAL LIST FOR RELAYS FOR 33kV TRAFO FEEDER
A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks
1 Breaker ON / OFF Digital Input
2 Breaker Trip Digital Input
3 86 Optd. Digital Input
4 TC -1 Healthy Digital Input
5 TC -2 Healthy Digital Input
6 EMPB Optd. Digital Input
7 Breaker Spring Charged Digital Input
Local Remote Swicth in Local Digital Input
8 Mode
Local Remote Swicth in Remote Digital Input
9 Mode
10 Feeder Isolator - 1 ON/OFF Digital Input
11 Adjacent feeder -2 relay fail Digital Input
Transformer Trouble Aux. Relay - Digital Input
12 1
Transformer Trouble Aux. Relay - Digital Input
13 2
Transformer Trouble Aux. Relay - Digital Input
14 3
Transformer Trouble Aux. Relay - Digital Input
15 4
Transformer Trouble Aux. Relay - Digital Input
16 5
Transformer Trouble Aux. Relay - Digital Input
17 6

1 Feeder Isolator - 1 ON/OFF Goose from I/C Relay

2 Feeder Isolator - 2 ON/OFF Goose from I/C Relay


3 Bus Isolator ON/OFF Goose from I/C Relay
4 DC Supply Healthy Goose from I/C Relay
5 Bus PT Supply Fail Goose from I/C Relay

SIGNAL LIST FOR RELAYS FOR 33kV TRAFO FEEDER


A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks

TC Healthy for Indication &


1 TCH -1 Healthy Digital Output TC -Unhealthy for
annunciation

2 TCH -2 Healthy Digital Output For Trip & Annuciation


3 All protection trip to 86 relay Digital Output For Trip & Annuciation

4
Over current trip (Directional + Digital Output For Trip & Annuciation
Non - directional)

5
Earth fault trip (Directional + Digital Output For Trip & Annuciation
Non - directional)
6 U/F & O/F Trip Digital Output For Trip & Annuciation

7
Breaker Close Command from Digital Output
Relay

8
Breaker OFF Command from Digital Output
Relay
Annunication + Adjacent
9 Feeder Protection Relay Fail Digital Output relay input
10 Close Permissive from Relay Digital Output

11 Transformer Trouble alarm Optd For Trip & Annuciation

12 Transformer Trouble Trip Optd For Trip & Annuciation


13 87T Optd For Trip & Annuciation
14 64R Optd. For Trip & Annuciation
15 Standby Earth fault Optd. For Trip & Annuciation
For Alarm Purpose only. No
16 Over - fluxing Condition Trip.
SIGNAL LIST FOR RELAYS FOR 11kV OUTGOING FEEDER
A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks
1 Breaker ON / OFF Digital Input
2 Breaker Trip Digital Input
3 86 Optd. Digital Input
4 TC -1 Healthy Digital Input
5 TC -2 Healthy Digital Input
6 EMPB Optd. Digital Input
7 Breaker Spring Charged Digital Input
Local Remote Swicth in Local Digital Input
8 Mode
Local Remote Swicth in Remote Digital Input
9 Mode
10 Line Isolator ON/OFF Digital Input
11 Feeder Isolator ON/OFF Digital Input
12 Line Isolator E/s ON/OFF Digital Input
13 Adjacent feeder relay fail Digital Input
14 Spare Digital Input
15 Spare Digital Input
16 Spare Digital Input

1 Feeder Isolator - 1 ON/OFF Goose from I/C Relay

2 Feeder Isolator - 2 ON/OFF Goose from I/C Relay

3 Bus Isolator ON/OFF Goose from I/C Relay


4 DC Supply Healthy Goose from I/C Relay
5 Bus PT Supply Fail Goose from I/C Relay

SIGNAL LIST FOR RELAYS FOR 11kV OUTGOING FEEDER


A) List of Digitial Inputs:
SL. No Signal Description Type of Signal Remarks

TC Healthy for
Indication & TC
1 TCH -1 Healthy Digital Output -Unhealthy for
annunciation
For Trip &
2 TCH -2 Healthy Digital Output Annuciation
For Trip &
3 All protection trip to 86 relay Digital Output Annuciation
For Trip &
4 Over current trip Digital Output Annuciation
For Trip &
5 Earth fault trip Digital Output Annuciation
For Trip &
6 U/F & O/F Trip Digital Output Annuciation

7
Breaker Close Command from Digital Output
Relay

8
Breaker OFF Command from Digital Output
Relay
Annunication +
9 Feeder Protection Relay Fail Digital Output Adjacent relay
input
10 Close Permissive from Relay Digital Output

Das könnte Ihnen auch gefallen