Sie sind auf Seite 1von 4

Cummins® INSITE™ Newsletter

December 2011
Inside This Issue: Data Monitor Logger Limits
Data Monitor Logger Limits 1 Recent versions of INSITE have implemented Upper and
Lower limits for Data Monitor/Logger parameters for some
Upcoming Cummins INSITE 1
engines. In INSITE v7.5 and later versions, the Out of
Changes
Range window at the top of the Data Monitor/Logger
Cummins INSITE Overview 1 window now highlights parameters that exceed the Upper
Presentation Location Information or Lower limits.
Customer Satisfaction Survey 1
Information These limits are intended to highlight potential conditions
and should not be used as a basis for troubleshooting.
Cummins INSITE v7.5.2 Overview 2
Because of the confusion this could cause for some, these
limits are currently under consideration for removal from
Calibration Download for Dealers 3
INSITE.
INLINE 6 Datalink Adapter 4
Announcement For more information, refer to TSB #110264 in QSOL.

INSITE Newsletter Information 4

Upcoming Cummins INSITE Changes


Cummins INSITE will be making several changes in the Fall of 2012. Some of the changes are as follows:
 Will require an internet connection at least once every 90 days and when registering a new
license or transferring license.
 Will no longer support Windows XP 32-bit and 64-bit Operating Systems.

 Will no longer support Vista 32-bit and 64-bit Operating Systems.

Cummins INSITE Overview Presentation Location Information

The Cummins INSITE overview presentation is located on the INSITE DVD-ROM under the auto run menu.

The latest Cummins INSITE v7.5.2 overview presentation is available on the INSITE website under News &
Information > INSITE Training & Processes: https://insite.cummins.com/insite/info/index.html.

Customer Satisfaction Survey


As part of a continuous improvement effort to Cummins Electronic Service Tools, we need your feedback.
Please take a few minutes of your time to answer the Customer Satisfaction Survey provided in the following
link: https://insite.cummins.com/insite/info/index.html. The survey is on the News & Information page
below the General Information.

Please feel free to forward this survey to your customers.

Cummins INSITE Newsletter 1 December 2011


Cummins® INSITE™ Newsletter
December 2011
Cummins INSITE v7.5.2 Overview
We are pleased to announce that INSITE v7.5.2 is available for download through the Cummins Inc. Update
Manager. This supports all new and existing Cummins engine platforms.

Note: INSITE v7.5.1 or INSITE 7.5.1 SP2 must be installed before installing INSITE v7.5.2. The INSITE
v7.5.1/INSITE v7.5.1 SP2 download will be a free download using the Cummins Inc. Update Manager.
However, the DVDs will be available for purchase from your local distributor. Please contact your local
distributor for pricing information.

New Engines Supported


 ISF2.8 CM2220 AN
 ISF3.8 CM2220 AN
 ISF2.8 CM2220 IAN
 ISF3.8 CM2220 IAN

New Features Supported


Parking Brake - Switch Logic
The Parking Brake Switch State feature has been expanded to allow the logic of the parking brake switch to
be set to either Active Open or Active Close. This only applies to: ISL G - CM2180A, ISB4.5/6.7 ISD4.5/6.7
CM2150 SN, and ISL8.9 CM2150 SN.

Vehicle Speed Based Device Driver A & B


The Vehicle Speed Based Device Driver A or Vehicle Speed Based Device Driver B will activate an OEM
installed device (e.g. electrical relay) with an active low or an active high signal from the ECM. This only
applies to ISL G - CM2180A.

New ECM Diagnostic Test Supported


VGT Hysteresis Test
This test will request the VGT to exercise the actuator, and measure the range of the actuator as well as the
motor effort. The ECM will determine the VGT state, and return a pass or fail message. This only applies to:
ISB6.7 CM2250, ISC8.3 CM2250, ISL9 CM2250, and ISX 11.9/15 CM2250.

The following issues that were seen in the previous version of INSITE have been fixed in this release
of INSITE v7.5.2:
 INSITE does not display the Duty cycle Monitor data graph completely.
 INSITE uses excess paper when printing the Audit Trail live and from an ECM Image.
 INSITE does not display the column names when printing the Audit Trail.
 INSITE does not display the Vehicle Speed Sensor Type in Turkish.
 Updated several parameters Minimum and Maximum limits and removed the Sensor Voltages limits
on Data Monitor/Logger.
 INSITE only allows 65 characters to be entered in the Log and Event Descriptions.
 INSITE OBD monitors not supported message modified.
 INSITE has intermittent communication loss.
Operating Systems Supported
Windows® XP 32-bit and 64-bit
Windows® Vista 32-bit and 64-bit
Windows® 7 32-bit and 64-bit (Recommend Windows 7 32-bit)
For more information, visit https://insite.cummins.com/insite/info/min_pc_hw_req.html.

Cummins INSITE Newsletter 2 December 2011


Cummins® INSITE™ Newsletter
December 2011
Calibration Download for Dealers
A Six Sigma project that allows users to download engine calibration files through QuickServe Online (QSOL)
has been completed. Delivery of engine calibrations are now available over the internet for Dealers, Joint
Ventures and Original Equipment Manufacturers (OEM) as of July 2011.

One benefit of this project is rapid calibration deployment, which improves customer uptime. Delays in
calibration delivery can prove extremely expensive for customers based on steady operation repairs and
scheduled or unscheduled downtime.

To access this on QSOL, users need a valid Cummins INSITE Pro license and an active INCAL subscription.
If the user discontinues the INCAL subscription, access to downloading the calibration through QSOL will be
removed.

Just open QuickServe Online and click on the “Service” tab:

Then click on “Calibration Downloads” in the related information panel:

The resulting page will contain a link to a document which will walk you through the steps needed to
downloading INCAL files.

Cummins INSITE Newsletter 3 December 2011


Cummins® INSITE™ Newsletter
December 2011
INLINE 6 Datalink Adapter Announcement
Cummins INLINE 6 – Product Announcement
We are pleased to announce the release of the INLINE 6 USB/Serial Data Link adapter for combined
J1708/J1939/J2534 protocol support.

Executive Overview:
The Cummins INLINE 6 Data Link Adapter communicates with ECMs using J1939 and J1708 protocols
through applications that are compatible with the RP1210 A/B standards.

INLINE 6 Adapter is designed to be faster, more reliable, and more robust than its predecessor INLINE 5.

The INLINE 6 hardware is also capable of supporting the (*) protocols in the future:

 CAN - J1939/CAN125/CAN250/CAN500
 2nd CAN - J1939/CAN125/CAN250/CAN500
 J1587/J1708
 * ISO 15765
 * J2534

Feature Summary:
INLINE 6 Data Link Adapter is designed to take full advantage of the faster speed of the J1939 network. The
INLINE 6 adapter comes with fast processor speed, robust error handling algorithms, large memory buffers,
and sophisticated filtering. This is particularly beneficial as databases are being more heavily loaded with
faster message broadcasts from control modules and multiplexed instrument units. Features include:

 Latest, most powerful hardware


 USB interface on adapter with screw-on strain relief cables for robust connection
 USB powered using a PC or vehicle
 Rugged design and durable casing
 1 Year Cummins Warranty against hardware and software malfunction
 Genuine Cummins Product

For the complete product announcement, please go to the INLINE website, http://www.inline.cummins.com/

INSITE Newsletter Information


The Cummins INSITE Newsletter includes information on upcoming releases, the latest production release
information, new features, and other items concerning INSITE.
If you have any suggestions for possible topics or changes to the Cummins INSITE Newsletter, please
contact the INSITE Help Desk at 1-800-433-9341 Option 1.

Cummins INSITE Newsletter 4 December 2011