Sie sind auf Seite 1von 2

Rapid Visual Screening of Building for Potential Seismic Hazards

FEMA-154 Data Collection Form HIGH Seismicity


Address: CARIG SUR , TUGUEGARAO CITY
ZIP### 3500
Other Identifiers
No.Stories 2
Year Built 1990-2012
Screener Date 07/11/2018
Total Floor Area (sq.m) 960 SQ.M
Building Name UST FIC BUILDING
Use SCHOOL

OCCUPANCY SOIL TYPE FALLING HAZARDS

Assembly Govt. Office Number of Persons A B C D E F X


Commercial Historic Residential 0-10 11-100 Hard Avg. Dense Stif Soft Poor Unreinforced Parapets Cladding Other
Emer. Services Industrial School Rock Rock Soil Soil Soil Soil Chimneys
101-1000 1000+
BASIC SCORE, MODIFIERS, AND FINAL SCORE,S
BUILDING TYPE W1 W2 S1 S2 S3 S4 S5 C1 C2 C3 PC1 PC2 RM1 RM2 URM
(MRF) (BR) (LM) (RC,SW) (URM INF) (MRF) (SW) (URM INF) (TU) (FD) (RD)

Basic Score 4.4 3.8 2.8 3.0 3.2 2.8 2.0 2.5 2.8 1.8 2.8 2.4 2.8 2.8 1.8

Mid Rise (4 to 7 stories) N/A N/A 0.2 0.4 N/A 0.4 0.4 0.4 0.4 0.2 N/A 0.2 0.4 0.4 0.0

High Rise (> 7 stories) N/A N/A 0.6 0.8 N/A 0.8 0.8 0.6 0.8 0.3 N/A 0.4 N/A 0.6 N/A

Vertical Irregularity -2.5 -2.0 -1.0 -1.5 N/A -1.0 -1.0 -1.5 -1.0 -1.0 N/A -1.0 -1.0 -1.0 -1.0

Plan Irregularity -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5

Pre-Code (1972) 0.0 -1.0 -1.0 -0.8 -0.6 -0.8 -0.2 -1.2 -1.0 -0.2 -0.8 -0.8 -1.0 -0.8 -0.2

Post Benchmark (1992) 2.4 2.4 1.4 1.4 N/A 1.6 N/A 1.4 2.4 N/A 2.4 N/A 2.8 2.6 N/A

Soil Type C 0.0 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4

Soil Type D 0.0 -0.8 -0.6 -0.6 -0.6 -0.6 -0.4 -0.6 -0.6 -0.4 -0.6 -0.6 -0.6 -0.6 -0.6
0.0 -0.8 -1.2 -1.2 -1.0 -1.2 -0.8 -1.2 -0.8 -0.8 -0.4 -1.2 -0.4 -0.6 -0.8
Soil Type E
FINAL SCORE,S 2.8
COMMENTS
DETAILED
FALLING HAZARDS STRUCTURAL DEFFECTS NOTE: BUILDING WAS RENOVATED ON 2012
Evaluation
1. BROKEN WINDOW GLASS 1. EXPOSED RSB (2ND FLR) FOR THE SECOND FLOOR LEVEL Required
2. DAMAGED CEILING (2ND FLR) 2. HONEYCOMB (2ND FLR)
3. HANGING ELECTRICAL WIRINGS
AND WIRINGS (2ND FLR)

YES NO

*=Estimated, subjective, unreliable data BR Braced Frame MRF Moment Resisting Frame SW Shear Wall
DNK=Do Not Know FD Flexible Diaphragm RC Reinforced Concrete TU Tilt Up
* Use 1972 and 1992 for Pre-Code and LM Light Metal RD Rigid Diaphragm URM INF
Post Benchmark year basis
Department of Public Works and Highways Issue Date:
Bureau of Design Doc. Code: DPWH-BOD-BD-QMSF-11

BUILDINGS DIVISION Revision No.: 0


SEISMIC VULNERABILITY RATING OF Page No.: 1 of 1
BUILDINGS

Building Name: UST FIC BUILDING


Location: CARIG, TUGUEGARAO CITY
CRITERIA FOR PRIORITIZATION OF PUBLIC BUILDINGS FOR INSPECTION
(EARTHQUAKE RISK ASSESSMENT)
1. PROXIMITY : PR SCORE
Proximity Rating (PR) :
less than 2 km from the fault 2 - 5 km from the fault greater than 5km from the fault 10 Pts.
30 20 10
2. OCCUPANCY : OR SCORE
Occupancy Rating (OR) :
Hospitals and Emergency Treatment Areas, Evacuation Centers, Public School Buildings
30
Power and Communication Related Buildings, Fire and Police Stations,
30 Pts.
Aviation Control Towers, Emergency Command Centers
25
Other Public Buildings
10
3. CONSTRUCTION DATE : 1990 CDR SCORE
Construction Date Rating (CDR) :
before the year 1992 between year 1992 to 2010 after the year 2010 20 Pts.
20 15 10
4. BUILDING HEIGHT : BHR SCORE
Building Height Rating (BHR) :
low-rise (1-3 stories) mid-rise (4-7 stories) high-rise (greater than 7 stories) 20 Pts.
20 15 10

TOTAL SEISMIC RATING: (PR + OR + CDR + BHR) 80/100 Pts.

NOTE: 1. ) The higher the total seismic rating, the higher prioritization/ranking
for inspection of the building
2.) For buildings located on known fault lines shall be recommended for demolition

PRIORITIZATION RANKING

NOTES / REMARKS:

RATED BY (NAME & SIGNATURE): DATE November 07, 2018