PROJECT :- DESIGN OF FORMWORK FOR LVUP SLAB DATE :- 16/11/2018

CLIENT : - M/S GAWAR CONSTRUCTION DESIGN BY : GAURAV

1. Design of shuttering plate

Length of shuttering plate 0.9 mm m


Width of shuteering plate 0.9 mm m
Thickness of shuteering plate 3.2 mm mm
Thickness of top slab 0.6 mm m
Load due to concrete 18.8 mm KN/m
(including vibration effect)
Self wt. of plate 0.2 mm kn/m2

Construction Live load 3.6 mm kn/m2


Total Load on Plate 22.6 mm

Factored stress in the plate 0.2 mm N/mm2


X-Sectional area of Plate 2756.3 mm mm2
Section modulus 1447.0 mm mm3
Fy 240.0 mm N/mm2
Fyd (Fy/ϒm0) 218.2 mm N/mm2

Md 315715.9 mm N-mm
Permissible stress 114.5 mm N/mm2 > 0.15
OK

Angle Support on Edge Plate ISA 65X65X6

Staad Output
Factored moment = 0.446 KN-m
Factored Shear force = 2.279 KN

Section Properties
Area = 744.0 mm
Width of flange(bf) = 65.0 mm
Section Modulus = 6200.0 mm3
r min = 6.5 mm
Thickness of flange (tf) = 6.0 mm
Thickness of web (tw) = 6.0 mm
Depth of section (h) = 65.0 mm
Weight of angle section = 6.0 mm

Analysis of Section
Fy = 250.0 mm N/mm2
ε = (250/fy)^0.5 = 1.0 mm
b/ tf = 10.8 mm Compact Section
d/tw = 10.8 mm Compact Section
βb = 1.0 mm

Moment of resistance of section


kL/r = 87.500
h/tf = 10.833
λLT = 0.633
αLT = 0.21
φLT = 0.746
ΧLT = 0.877
fcr,b = 624.563
fcd = 199.357
Md = 1236014.3 N-mm
Moment on section = 446000.0 N-mm OK

SHEAR RESISTANCE OF SECTION


Vd = Afy/(3)^0.5 = 107.4 KN
SHEAR FORCE ON SECTION OK