Sie sind auf Seite 1von 5

Friday, November 15, 2002

V-MAC III SERVICE SOFTWARE V.2.6.12

The V-MAC III Service Software v.2.6.12 effectivity date is 11/15/02. The software
is a fully 32-bit RP1210A-compliant application and will work with MS Windows
95/98/ME, MS Windows NT/2000 & XP (when using an RP1210A-compliant data link
adapter) and both the Kent-Moore J-38351-D and J-45537-PLC serial data link
adapters. NOTE: J-38351-D support under Win NT/2000 & XP uses the adapter in
RP1210A mode (only) and requires the installation of the updated Noregon Standalone
API v.2.5 device drivers. This release of diagnostic software includes support for
all V-MAC III module combinations including E-Tech, CCRS, ASET IEGR, and ASET CEGR
through 1MS364, or V-MAC III Step 9B.

Also included on this CD-ROM are the device drivers necessary to use the Kent-Moore
J-45537-PLC data link adapter with V-MAC III Service Software. They are located in
the ...\J-45537-PLC Drivers v.2.5 directory and supercede the drivers distributed
with the J-45537-MACK essential service tool kit. Note that this version of the
data link adapter drivers will also support the Kent-Moore J-38351-D in RP1210A
mode, and will greatly assist with all reprogramming diagnostics.

NOTE

USING ELECTRONIC SERVICE BULLETIN TO DEALERS 700-2002-228-01, "UNINSTALLING V-MAC


SOFTWARE", UNINSTALL ALL v.2.4.X AND PRIOR RELEASES OF V-MAC SERVICE TOOLS FOR
WINDOWS BEFORE INSTALLING V.2.6.X V-MAC SERVICE TOOL SOFTWARE. ALSO, REMOVE ANY
REMAINING ICONS TO V-MAC WINDOWS-BASED SERVICE SUPPORT SOFTWARE. AN ENTIRELY NEW
DIRECTORY STRUCTURE WILL BE INSTALLED WITH THIS RELEASE. FAILURE TO FOLLOW THE
UNINSTALLATION PROCESS PRIOR TO INSTALLING V.2.6.X TOOLS WILL RESULT IN PROGRAM
INSTABILITIES AND FAILURE.

INSTALLATION:

To install J-45537-PLC RP1210A drivers:

1. Insert the CD into your CD-ROM drive.

2. Navigate to your drive, and then the ...\J-45537-PLC Drivers v.2.5 directory.
Run Setup.exe, and follow the onscreen instructions.

To install V-MAC III software:

1. Insert the CD into your CD-ROM drive.


2. Navigate to your drive, and then the ...\V-MAC III Service Tools v.2.6.12
directory. Run Setup.exe, and follow the onscreen instructions.

3. When running the program for the first time, ensure that you properly select the
data link adapter that you will be using with the software.

As always, if you experience difficulty with these products, or have additional


questions or concerns, please contact the Mack Trucks, Inc. System Support Center at
(800)247-0039.

V-MAC SUPPORT SOFTWARE V.2.6.X REVISION HISTORY

May 2, 2002

Service Software v.2.6.4 - Test

SD and CDP
----------

1. Can now recognize Step 9B VECU (1MS364)

CDP
----------

1. Corrected errors in EECU software identification.


2. Driver ID Settings now is properly enabled when VIP or Co-Pilot are available.
3. Tab key moves the cursor around the screen in a logical way.
4. At startup, if the communication setup is not correct, all buttons on the main
menu are disabled except "Preferences."
5. It is now possible to view VECU parameters when the EECU is not available.

SD
----------

1. Increased the performance of Monitor Parameters and addressed the frequent run-
time errors.
2. Removed the program timing problems that occasionally resulted in screen objects
appearing at the wrong time.
3. Removed Min and Max options from VGT calibration test screens.
4. Restored the "save test results" option to the Run-up test and the Compression
test.

June 14, 2002

Service Software v.2.6.5 - Dealer Release

SD and CDP
----------

1. Corrected the variations in screen color observed with Windows 2000 on LCD
screens.
2. ASCII data dictionary (v2.0.0.4) has been updated to provide correct messages for
EDC7 PID/SIDs and FMIs.

Page 2 of 5
CDP
----------

1. Now properly clears the EECU fault table before programming.


2. Eliminated error message that was incorrectly generated when programming EUP cal
codes on non-CCRS engines.
3. Eliminated the J1587 fault that was occasionally generated when resetting the
ECUs.
4. Corrected a problem programming the engine brake parameter in the EECU
(previously, it was not possible to turn the brake off in all cases).

SD
----------

1. Changed communication to address slow performance and read errors for


a. Vehicle Information
b. Programming History
c. Vehicle Data Log
d. Maintenance Data Log
e. Fault table
f. Fault Reporter
2. Removed the unwanted confirmation message from the Snapshot function of Monitor
Parameters.
3. Corrected errors reading the fault tables when returning to the main menu from
Monitor Parameters.
4. Corrected the error generated in Windows 2000 when attempting to save default
parameters in Monitor Parameters.

June 24, 2002

Service Software v.2.6.6 - Test

SD and CDP
----------

1. Fixed the time zone calculation problem which caused overflow errors in some time
zones.
2. Added recognition of Step 3 EDC7 (1MS368).
3. Replaced the series of confusing startup messages with a single, more user-
friendly one.

CDP
----------

1. Removed Driveshaft Speed Limit Lower RPM from View/Print Current Parameters (the
parameter is not programmable).

SD
----------

1. Now properly disables features with Cummins engines that are not applicable.
2. Restored the indicator in the fault displays that shows which faults are recorded
in the Fault Reporter.

Page 3 of 5
July 2, 2002

Service Software v.2.6.7 - Test

CDP
----------

1. Corrected a table read problem that occurred with Kent-Moore adapters.

Wednesday, July 31, 2002

Service Software v.2.6.8 - Test

SD and CDP
----------

1. Installs MSERIAL.vxd to the Windows\System directory, which enables Ekernel to


reliably locate it. Previous versions installed MSERIAL.vxd to the Mack Shared
directory. Ekernel does not reliably locate MSERIAL.vxd when it is in the Shared
directory.

August 28, 2002

Service Software v.2.6.9 - Test

CDP
----------

1. Added the option to enable the MACK Power Leash engine brake.
2. Corrected a problem which caused incorrect programming history records to be
written to the VECU.
3. Removed the unused option "Reset Oil Change via Electronic Dash" in Fleet Display
and Trip Parameters.

SD
----------

1. Added the "Advanced Display" to the Parameter Monitor.


2. Fixed errors in the date and time calculations in the Parameter Monitor and the
Fault Reporter. Dates and times are now reported in local time, not GMT.
3. Corrected a timing error in the Compression Test that resulted in a false error
message.
4. Fixed an error in %Sweet Spot calculations in Vehicle Data Log Display
5. Fixed a problem reading options selected using the Configuration Manager. This
problem caused the Parameter Monitor to display parameters in English units
regardless of which units had been selected.
6. Changed the Fault Display to reliably clear faults.
7. Fixed a timing problem in the VGT calibration function that caused a false error
message to appear with newer EDC7 modules.

September 6, 2002

Service Software v.2.6.10 - Test

Page 4 of 5
SD
----------

1. Enabled Cummins pedal calibration function.


2. Removed switch status section from the parameter display for the Cummins
application.
3. Fixed incorrect parameter scaling in the Advanced Display.
4. Corrected a logic error in the Park Brake status in the Switch Status Display.
5. Enabled the Advanced Display for Step 2 EDC7 (1MS334A).

October 15, 2002

Service Software v2.6.11 - Dealer Release

CDP
----------
1. Maintenance broadcast and blackout times are correctly displayed in local time
(not in GMT).
2. Option to enable Power Leash brake is now available.

SD
----------

1. Times displayed in the Monitor Parameters option and in the Fault Reporter are
now correctly shown in local time (not in GMT).
2. Corrected a run-time overflow error that can occur when an invalid date is read
from the VECU during the Maintenance Data Log Display.
3. The mouse pointer now changes to an hourglass while reading data for the All
Active Faults display, because this process can take several seconds.
4. Corrected timing and display problems that can occur when enabling or disabling
the POC option.

November 15, 2002

Service Software v2.6.12 - Full Production (Dealer & Customer) Release

SD and CDP
----------

1. Fixes a runtime error problem (subscript out of range) that has been seen with
specific EECU data files, in which the software ID has been defined in a non-
standard way. The problem is known to exist with V-MAC III Step 4 EECUs with a
1MS571P13 data file.

Page 5 of 5