Sie sind auf Seite 1von 11

International Journal of Trend in Scientific Research and Development (IJTSRD)

International Open Access Journal | www.ijtsrd.com

ISSN No: 2456 - 6470 | Volume - 2 | Issue – 6 | Sep – Oct 2018

A New Hybrid Synchronous Reluctance Machine Capable of


Ultra-High Output Power
S E Abonyi
Department of Mechanical, Nnamdi Azikiwe University, Awka, Anambra, Nigeria

ABSTRACT 1. INTRODUCTION
A new hybrid synchronous reluctance machine A synchronous machine is an ac rotating machine
capable of ultra-high Xd/Xq ratio output power has whose speed under steady state condition is
been studied. A d-q model (voltage and flux linkage) proportional to the frequency of the current in its
of the hybrid synchronous reluctance machine has armature. The magnetic field created by the armature
been idealized and developed. Also the impedance currents rotates at the same speed as that created by
and current loci from steady state analysis of the the field current on the rotor, which is rotating at the
machine was obtained. The effect of capacitor loading synchronous speed, and a steady torque results.
in the auxiliary winding was investigated. The power Almost all the electric power used throughout the
factor and torque developed in the hybrid world is generated by synchronous machine driven
synchronous reluctance machine was compared with either by hydro, steam turbine or combustion engine.
the conventional synchronous reluctance machine. Just as the induction machine is the workhorse when
The hybridized synchronous reluctance machine it comes to converting energy from electrical to
improved the major constraints of conventional mechanical, the synchronous machine is the principal
reluctance machine – low power output and poor means of converting energy from mechanical to
power factor due to low ratio of direct to quadrature electrical. Thus, the fundamental difference between a
axis reactance (Xd/Xq). To achieve this two elemental synchronous machine and an induction machine is
synchronous machines was conceived. Both were that the rotor currents of the induction machine are
internally wound with identical winding in the stator. induced while those of the synchronous machine are
The rotor of one of the synchronous reluctance not. The rotor of synchronous machine is equipped
machine component is round while the other has a with a field winding and one or two damper windings.
salient pole. Both machine halves were mechanically The rotor windings have different characteristics [1].
coupled together. One set of the winding of both
machines were connected in series and fed from the A good number of researches done on synchronous
main while the other set was also connected in series reluctance machine in the past three decades have
(but transposed between the two section of the of the suggested the machine to be an attractive alternative
machine) and then connected to a balanced three to other AC machines (permanent magnet, Induction
phased variable capacitance load. It was the and Switched reluctance machines) in high
capacitance loading of the auxiliary winding makes performance, variable speed applications. This is as a
the overall Xd/Xqratio of the hybrid machine to be result of the ability of the machine to withstand harsh
variable that can theoretically attain values between environment, its low inertia, ease of construction, high
zero and infinity. This translates to ultra-high output power to weight ratio and good acceleration
and unity power factor. performance [3-10]. Anih L U [2] coupled two
machines- the salient pole machine and a round rotor
Keyword: Xd/Xq ratio, dual-winding machines, power machine. Each of the machines has two separate
factor, two-axis theory. windings; the main and auxiliary windings, with the
main windings connected in series while the auxiliary
windings are connected in anti-series and feed a
capacitor. He used the electric circuit theory method

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 884
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
to show that the ratio of Ld/Lq can be increased to 3. Fundamental Concept of the hybrid
infinity by varying the capacitance values. synchronous reluctance machine
Subsequently the study of reluctance machines has The synchronous reactance of the round rotor is X S
been extended to coupled machine in which the and the direct axis reactance of the salient pole is X d .
combination of round and salient pole machine is one
of them [10]. Different rotor configurations have gone When the salient pole operates on the d-axis and the
through different design analysis and techniques to synchronous reactance is made equal X d . The
obtain a better performance. Some of the successes on overall reactance is X D = xd + xd = 2 X d
the rotor configurations are well reported in [5], [6],
[11]-[14]. The geometric approach via rotor designs When the salient pole operates on the q-axis the
has improved the performance characteristics of overall reactance X Q = xd + x q
reluctance machines. Since 1963, Lawrenson and Agu
[15, 16, 17] extensively developed the segmental rotor
design. Lawrenson improved his segmental rotors by However the operation of a synchronous machine is
introducing q-axis channels [18] and used them for dependent on X D / X Q ratio. The preliminary analytic
both single-speed [18] and multi-speed [19] study shows that if the auxiliary winding transposed
applications. Due to the larger saliency ratio, he between the two machines feeds a balanced
obtained performance better than equivalent capacitance load, the overall X Q is reduced while the
conventional machine designs
X D remains unaffected. It therefore follows that for a
2. Description of the Hybrid Machine typical value of X C that X Q can be even zero
The machine comprises two machines of a salient resulting in an ultra-high output power.
pole and a round rotor that are integrally wound and
mechanically coupled together. Each machine unit has 4. Hybrid Machine Model Development
two sets of three-phase windings that are identifiable Since synchronous machine generally operate as
as the main and auxiliary windings respectively. The
generators, it is convenient to assume that the
main windings of both machines are connected in
direction of the positive current is out of the terminal
series; the auxiliary windings are also connected in
of the stator windings. The model presented here is
series but transposed in passing from one machine to
for a machine that has no rotor conductors, as the
the other and short-circuited. By tuning the load
primary interest here is the steady state performance
capacitance of the auxiliary winding, it begins to vary
of the machine at differing capacitance values. In the
the operational q-axis reactance (Xq) of the machine
analysis that follows, upper case subscripts represent
from zero to infinity, while the d-axis reactance (Xd)
main winding terms while the lower case subscripts
remains constant. Thus a variable Xd/Xq ratio is
are for the auxiliary winding terms. The model
achieved which varies from zero to infinity and hence
developed relies on the usual assumptions of
the output power which is directly proportional to it.
modelling synchronous machines as contained in
Fig.1 below shows the connection diagram of the
classical texts [14] and [17] and on the semi intuitive
hybrid machine.
per-phase circuit shown inFigure 2.

Fig.1 Connection Diagram for Main Winding of the Figure 2: Per-phase connection circuit of the hybrid
Hybrid Machine machine

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 885
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
Six voltage equations for the hybrid machine in stator reference frame can be written as;
where VE represents the main and auxiliary winding voltages and is given in matrix form by;
V
E
=  V ABC V
abc
 =  V A VB VC V V V
a b c
T (1)

The current matrix is given by;


I
E
=  I ABC I
abc
 =  I A I B IC I
a
I
b
I
c
T (2)
The resistance matrix is given by;
R
E
= diag R  A
R
B
R
C
R R R
a b c
 (3)

In the above equations and everywhere in this report, upper case subscript will represent main winding
quantities and lower case subscript will represent auxiliary winding quantities. Thus the flux linkage (E )
equation in phase variable becomes;
L L12   I ABC   LSS + LRR LMS + LMR − 2 LL   I ABC 
E =  11    =   . (4)
 L21 L22   I abc   MS + LMR − 2 LL
L LSS + LRR   I abc 
This implies that;
  I   LSRM MUTA  I ABCS 
 =  ABCS   ABCS  =   I  (5)
E  
 abcs   I
  abcs 
  MUTM LSRA 
 abcs 
where;
LSRM is the inductance matrix of the main windings connected in series = L11. MUTA is the mutual
inductance matrix between the main and auxiliary windings as seen by the auxiliary winding current = L12.
MUTM is the mutual inductance matrix between the main winding and auxiliary winding as seen by the main
winding current = L21. LSRA is the inductance matrix of the auxiliary winding = L22. In equation (4), E is a
matrices representing;
LSS which is a 3x3 inductance matrix of the stator three phase winding in the salient pole half of the machine

and, LRR 3x3 inductance matrix of the round rotor part of the machine.
Each of the LRR and LSS has their respective leakage parts in the appropriate places in (9) and (13). Since we
assumed that the main and auxiliary windings are identical and both are mutually coupled and occupy the same
slot positions, we equate the mutual inductance between the set of main and auxiliary windings. LL is the 3x3
leakage inductance matrix of any of the winding of either the round rotor and salient pole halves of the hybrid
machine which are also equal. The inductance of the two main windings connected in series represented by
LSRM is given as;
LSRM = LRR( Round RotorMachine ) + LSS ( Salient poleMachine )
= LRR + LSS (6)
The total inductance of auxiliary winding represented by LSRA is given as;
LSRA = LSRM (7)
But
   1  1  
 Lls + Lo − Lms cos( 2 r ) Lo − Lms cos 2( r − ) Lo − Lms cos 2( r + )
2
 Lls + 3 Lmd − 13 Lmd − 13 Lmd  − − 
2 3 2 3
   1  2 
LSRM =  − 13 Lmd
2
Lls + Lmd − 13 Lmd  +  − Lo − Lms cos 2( r − ) Lls + Lo − Lms cos 2( r − )
1
− Lo − Lms cos 2( r +  )  (8)
 3   2 3 3 2 
 −1L  1  2 
Lls + Lmd 
1
 − Lo − Lms cos 2( r +  ) Lls + Lo − Lms cos 2( r +
2
 3 md
− 13 Lmd −
 2 Lo − Lms cos 2( r + ) )
3  3 2 3 

The inductance matrix for any of the two stator windings of the salient pole machine is well known from

literature [20] and is given as:

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 886
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
 1  1  
 Lls + Lo − Lms cos 2 r − Lo − Lms cos 2( r − )
2 3
− Lo − Lms cos 2( r + ) 
2 3
 1  2 
LSS
1
= − Lo − Lms cos 2( r − ) Lls + Lo − Lms cos 2( r − ) − Lo − Lms cos 2( r +  ) 
 (9)
 2 3 3 2 
− 1 L − L cos 2( +  ) − 1 L − L cos 2( +  ) L + L − L cos 2( + 2 )
 2 o ms r
3 2
o ms r ls o ms r
3 
Lmd + Lmq Lmd − Lmq
Where Lo = Lm = (10)
3 and, 3
The leakage inductance matrix is;
LL = diag LLS LLS LLS  (11)
But, For the round rotor machine half of the machine Lmd = Lmq ,and Lms = Lmd . This implies that Lo = 2 Lmd and Lm = 0 , so
3
its stator winding inductance matrix can be obtained by substituting the values of Lo and Lm into equation (12).
Thus;
 1 1 
 Lls + Lo − Lm − Lo − Lm
2
− Lo − Lm 
2
 1 
LRR =  − Lo − Lm Lls + Lo − Lm
1
− Lo − Lm  (12)
 2 2 
−1L −L 1
− Lo − Lm Lls + Lo − Lm 
 2 o m
2 

Therefore stator winding inductance matrix LRR becomes:


 2 
 Lls + 3 Lmd − −
1 1
3
Lmd 3
Lmd 
 
=  − 13 Lmd 
2
LRR Lls + Lmd − 1
3
Lmd (13)
 3 
 −1 L − 1
Lmd Lls +
2
Lmd 


3 md 3
3


Substituting (8) and (12) into (8), and making The LSRM inductance matrix becomes;
 2 2 
 A − B cos( 2 r ) C − B cos( 2 r −
3
) C − B cos 2( r + )
3 
 2 4 
LSRM = LSRA, =  C − B cos( 2 r − ) A − B cos( 2 r − ) C − B cos( 2 r )  (14)
 3 3 
C − B cos( 2 + 2 ) C − B cos( 2 r ) A − B cos( 2 r +
4 
)
 r
3 3 

 2 2 
 D − B cos 2 r F − B cos( 2 r − ) F − B cos( 2 r + ) 
3 3
 2 4 
MUTM = MUTA =  F − B cos( 2 r − ) D − B cos( 2 r − ) F − B cos 2 r  (15)
 3 3 
 F − B cos( 2 + 2 ) F − B cos 2 r
4
D − B cos( 2 r + )
 r
3 3 
1
A = 2 Lls + Lmd + Lmq , B=
1
(Lmd − Lmq ), C = − Lmd − Lmq , D = (Lmd + Lmq ), E = − (Lmd − Lmq ), F = (Lmd − Lmq )
1 1 1 1 1
3 3 2 6 3 6 6

The entire stator winding inductance matrix given in equation (16).


ABCS   LSRM MUTA − I ABCS 
  =   
LSRA 
(16)
 abcs   MUTM   − I abcs 
If we denote equation (16)by F , then;
Substituting the expressions of LSRM , MUTA, MUTM , LSRA into the matrix of F gives;

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 887
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
 2 2   2 2  
  A − B cos( 2 r ) C − B cos( 2 r −
3
) C − B cos 2( r + )
3  B − B cos 2 r F − B cos( 2 r −
3
) F − B cos( 2 r + ) 
3 
   
  C − B cos( 2 r + 2 ) 4
A − B cos( 2 r − ) C − B cos( 2 r )   F − B cos( 2 r − )
2 4
B − B cos( 2 r − ) F − B cos 2 r    I Q 
 3 3   3 3   
 2 4    4   I D
B − B cos( 2 r + )    
2
 C − B cos( 2 r + 3 ) C − B cos( 2 r ) A − B cos( 2 r + )   F − B cos( 2 r + 3 ) F − B cos 2 r
3   IO 
F =  
3 
  ( 17 )
  B − B cos 2 2 2   2 2    I q 
F − B cos( 2 r − ) F − B cos( 2 r + )  A − B cos( 2 r ) C − B cos( 2 r − ) C − B cos 2( r + )
 r
3 3 3 3   Id 
 2 4   2 4   
  F − B cos( 2 r − ) B − B cos( 2 r − ) F − B cos 2 r   C − B cos( 2 r + ) A − B cos( 2 r − ) C − B cos( 2 r )    I o 
 3 3   3 3 
  F − B cos( 2 + 2 ) F − B cos 2 r
4 
B − B cos( 2 r + ) 
 2 4 
A − B cos( 2 r + )  

  r
3 3  C − B cos( 2 r + 3 ) C − B cos( 2 r )
3  

4.1 Transformation to dqo


It is seen that every element of the sixth order inductance matrix is dependent on rotor position  r . Therefore, a
transformation to rotor reference frame is suitable to eliminate this dependence. We adopt Park’s
transformation equation, Fdqo = [Tdqo ( r )][ Fabc ] where the dqo transformation matrix is defined as;
 2 2 
 cos  r cos( r −
3
) cos( r + )
3
2  2 2 
[Tdqo ( r ) ] =  sin  r sin(  r − ) sin(  r + )  . (18)
3  3 3 
 1 1 1 
 2 2 2 
The transformation will be performed on the entire inductance matrix  since all of them are on the stator, so F

the augmented matrix will become F


 [T ( ]* LSRM * [Tdqo ( r ) ] −1 [Tdqo ( r ) ]* MUTA * [Tdqo ( r ) ] −1 
 F =  dqo r )  (19)
[Tdqo ( r ) ]* MUTM * [Tdqo ( r ) ] [Tdqo ( r ) ]* LSRA * [Tdqo ( r ) ] −1 
−1

where; the transformation  QDS


L LQDA 
 yields,
 LQDM LQDR 
 Lmd − Lmq 0 0
2 Lls + Lmd + Lmq 0 0  LQDA = LQDM =  0 0 0
LQDS = LQDR =  0 2 Lls + 2 Lmd 0   0 0 0
 0 0 2 Lls 

The entire inductance matrix for stator reference frame yields,


2 Lls + Lmd + Lmq 0 0 Lmd − Lmq 0 0 I Q 
 0 2 Lls + 2 Lmd 0 0 0 0   I D 

 0 0 2 Lls 0 0 0 I O 
 QD =     .... (20)
 Lmd − Lmq 0 0 2 Lls + Lmd + Lmq 0 0  I q 
 0 0 0 0 2 Lls + 2 Lmd 0  I d 
  
 0 0 0 0 0 2 Lls   I o 

It is easy to observe that the d-axis and q-axis flux linkages for the winding sets are:
  2(L + L ) 0  I D 
Dd =  D  =  ls md ............... (21)
 d   0 2(Lls + Lmd )  I d 
Q  (2Lls + Lmd + Lmq ) − (Lmd − Lmq )   I Q 
Qq =   =     ............... (22)
 q   − (Lmd − Lmq ) (2Lls + Lmd + Lmq )  I q 
  2 L 0  IO 
Oo =  O  =  ls ............... (23)
 0   0 2 Lls   I o 

Equation (21) shows that the overall d-axis inductances of the two windings sets are the same and completely
uncoupled while the overall inductance matrix of (22) shows the existence of a coupling term. This explains
why the d-axis reactance of the hybrid machine remains constant when the capacitive loading of the auxiliary
winding is varied and the q-axis reactance also varies.

4.2 Capacitor Voltage Equation

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 888
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
Capacitors have long been proven as power factor correcting devices. To use capacitors to assist an a.c motor,
there ought to be two sets of windings because if the capacitors are connected in series to a single-winding
machine, the impedance is drastically reduced and intolerably high current will be drawn. And if connected in
parallel the power factor of the supply source is improved with negligible improvement in motor performance.
A salient pole and round-rotor machine, each possessing two sets of windings were coupled together, the main
windings connected in series and powered from the mains while the auxiliary windings were specifically
connected to a balanced capacitor.

For the 3 – phase capacitive circuit connected to the auxiliary windings;


i
d
= q
abcs dt abcs
(24)
iqc −  r cv dc idc +  r cvqc
Applying Park’s transformation equations yields pv qc = and pvdc =
c c
Vd = X c iqc and − X c idc
At steady state the values of the derivatives are set to zero, hence

4.3 Hybrid Machine Voltage Equation in dqo Variables


The hybrid machine voltage equations in dqo variable are obtained for the main and auxiliary windings. Also
the capacitive voltage equation is incorporated into the voltage equation for the auxiliary winding since the
capacitor is connected to the auxiliary winding. In general, the voltage equation can be expressed in abcs and
dqos as;
VDS = − 2 RS I DS − QS + P DS (25 )
VQS = − 2 RS I QS +  DS + PQS (26)
VOS = − 2 RS I OS + POS (27)
Vds = − 2 rS I ds − qs + Pds + Vcd (28)
Vqs = − 2 rS I qs + ds + Pqs + Vcq (29)
Vos = − 2rS I os + Pos (30)

The dynamic equivalent circuit of the hybrid machine can be drawn based on equations (25) to (30) and shown
in fig. 3

(a) (b)
Figure 3 Dynamic equivalent circuit of the hybrid machine (a) q-axis (b) d-axis
5. Steady State Analysis Of The Hybrid Machine
In this section the steady state operation is examined to help us better understand the operational behavior of
the machine.

For the purpose of examining the steady-state performance of this machine, the parameters of a 4-pole, 2hp,
220V, 50Hz, synchronous reluctance machine [16] was used. The unsaturated reactances are Xmd = 124.21Ω,
Xmq = 78.72Ω and Xls = 12.0Ω. Since the stator winding of the machine is halved, the reactances will be
divided by a factor of 4 which will now give: Xmd = 31.05Ω; Xmq = 19.67Ω and Xls = 3.0Ω.

At synchronous speed the steady state mode, the following relationships exist between main winding and the
auxiliary winding rotor reference frame, steady state variable and the synchronous rotating phasor.

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 889
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470

FAS = ( FQS − JFDS ) e j (31)


Fas= ( Fqs − JFds ) e j (32)
Where, F can be voltage, current or flux linkage
 is the load angle. VQS = Vcos  VDS = Vsin 

Where, V is the root mean square value of the supply voltage and  is the load angle.
VAS e − j = 2 RS I A − 2 X d I r A − j (X d − X q )I r QS − j (X md − X mq )I r qs (33)
Vas e− j = 2 RS I a + 2 X d I r a + X C I a − j (X d − X q )I r qs − j (X md − X mq )I r QS (34)
It is now possible to assess the machine parameter variation in the steady-state using the equivalent circuit
shown if figure 3.2

Figure 4 Per-phase steady state equivalent circuit of the hybrid machine

5.1 Input impedance


The machine input impedance can be obtained by finding the ratio of the input voltage V AS to the main winding
current, IAS employing (35) or by using simple circuit theory approach of looking into the input terminals of
Figure 4. Both approaches will naturally give the same results, however for brevity we use the later and show
that the input impedance is given as:

(
Z = 2 rs + jX d + ) ( ( ))
2rs + j 2 X d − X c X (X mq + X md )sin e j
(
(2rs + (X mq − X md ))sin e j + j 2 X d − X c (35)
)
5.2 Axes reactances of the machine
In general, the impedance expression can be resolved to real (Re) and imaginary (Xe) terms. Aplot of real
versus the imaginary part of (35) for various values of X c with δ ranging from 0 to πgenerates a family of
circles as shown in Figure 6. Each of these circles (impedance loci) has aconstant d-axis reactance equal to
2 X D + ( X ls + X md ) but the quadrature axis reactance X Q varies.

5.2.1 Direct axis reactance


Using (28) in the limit that  → 0 and for negligible stator winding resistance, the overall d-axis reactance
is XD given by (36) which is clearly independent of the capacitive reactance:
X D + j 2 ( X ls + X md ) (36)
5.2.2 Quadrature axis reactance

In the limit that  → and for negligible stator winding resistance, the overall q-axis reactance is XQ
2
given by:
4 X md (X ls + X md + X mq ) + 4 X ls − (2 X ls + X md + X mq )X c
XQ = j (37 )
2 X ls + X md + X mq − X c

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 890
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
Evidently, it can be seen that only the effective quadrature axis impedance is influenced by the capacitance
connected to the auxiliary winding.

5.3 Xd/Xq ratio


The effective reactance ratio, XD/XQ of the hybrid machine can be closely examined by taking the ratio of (36)
to (37). It is easier to visualize this reactance ratio graphically as shown in Figure 6 where for varying XC plots
of XD, XQ and then XD/XQ are shown. In the plot, the values of capacitor (in μF) are given instead of XC in
order to justify that realistic values exist for evena value of zero quadrature axis reactance. From (37) it can be
shown that analytically, zeroquadrature axis reactance can be obtained when:
4(X md X mq + X ls X mq + X ls X md )
Xc = (38)
2 X ls + X md + X mq

For the machine under study this translates to a capacitance of about 67.4μF.

Figure /5: Variation of reactances and the reactance ratio with capacitance

5.4 Circle diagrams It is observed from Figure 6 that without the auxiliary
Examination of (35) shows that the loci of Z for winding (XC= ∞), the value of XD= 60Ωwhile the
different values of capacitance loading of the quadrature axis XQ= 50Ω, giving a very low XD/XQ
auxiliary winding XC as δ varies from 0 to π are ratio. The introduction of a variable capacitance load
family of circles with center: [0, (XD+XQ)]and radius . into the auxiliary winding makes the quadrature axis
(XD–XQ) where XQ is a variable parameter, which reactance XQ variable and can be made to vary from
depends on XC. zero to infinity. Some of the loci of the hybrid
machine are of special interest. For XC= 1.6Xd, the
All the circles are tangential to the line XD = 2Xd. The quadrature axis reactance XQ is completely
quadrature axis reactance XQ thus changes as XC
changes as shown in Figure 6a while the d-axis
reactance remains constant. For each impedance neutralized, (i.e. XQ= 0) by the capacitive reactance
locus, there is a corresponding current locus. Each of leading to infinitely high output power and unity
the current loci is tangential to IAS= VAS/(2Xd)point as power factor. Further increase in XC between 1.6Xd
shown in Figure 6b. The centers of such circles will and 1.67Xd, XQ becomes negative and the power
lie on the horizontal axis from +∞to –∞. The q-axis factor becomes leading. For the capacitive reactance
reactance can even be negative and may be greater XC= 1.64Xd, the center of the impedance locus
than XD in magnitude. The horizontal line Real(Z) = 0 coincides with the origin, i.e. |-XQ|=|XD|, the machine
which corresponds to Real(IAS) = 0 as shown in draws or supplies the same current irrespective of
Figure 6 marks the transition of the machine from load. When the current loci embraces the third
generating to motoring operations. At these points, the quadrant, the machine is able as a generator to supply
machine is neither motoring nor generating and the lagging power factor loads and as a motor to supply
input power VIcosφ supplies the winding losses only. leading power factor loads. For XC= 1.67Xd, XQ is
infinite and the corresponding current locus is IQ= 0.
The significance of this is that XQ is now greater than

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 891
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
XD and the operating axis of the machine shifts by π 6. Comparison of the Conventional Reluctance
radians and the Q-axis now becomes the no-load axis. Machine with the Synchronous Hybrid
Machine.
Between XC= 1.67Xd and 2Xd, the impedance loci flip The synchronous hybrid machine differs greatly from
over to the right hand of XQ= ∞ axis, inductive in conventional reliance machine in various way as
nature and shrinking. The shrinking of the flipped loci shown below.
is because the capacitive reactance is becoming large
and thus increasing the impedance of the auxiliary 6.1 Constructional features:
winding towards the open-circuit case, which is The synchronous hybrid machine consists of two
inductive in nature and in consequence, the current in machine elements that are mechanically coupled
the auxiliary winding decreases. Although resistance together and their stators are integrally wound while
was neglected in the plots its inclusion would have the conventional reluctance machine consists of one
shifted the impedance and current loci vertically machine element. Each stator of the synchronous
upwards above the horizontal axis by an amount equal hybrid machine consists of two windings called main
to the value of the resistance. and auxiliary winding. In order to accommodate the
two windings the slot of synchronous hybrid
machine’s depth is twice as that of conventional
machine.

6.2 Technique of Enhancing Xd/Xq Ratio


The enhancement of Xd/Xq ratio of the conventional
reluctance machine is through the manipulation of the
rotor geometry [14, 18 and 21], while in the
(a) synchronous hybrid machine, the enhancement of the
Xd/Xq ratio for a fixed rotor geometry is achieved by
using d-q analytical method. Here the quadrature axis
reactance Xq is modified by the capacitance load on
the auxiliary circuit while the Xd/ remains unaffected.

6.3 Output Power


The output power of the conventional machine is
known to be poor compared to induction machine of
the same size, thus putting the reluctance machine
into obscurity except for some control applications.
The low output power of the conventional reluctance
(b) machine accounts for its low Xd/Xq ratio. The output
Figure 6: (a) Impedance loci, (b) Current loci. power of the synchronous hybrid machine could be
increased theoretically without limit because of Xd/Xq
5.5 Power factor ratio can be anything from zero to infinity. The factor
The power factor of the hybrid machine is easily that may limit the output power are the conductor size
obtained from ac circuit theory as: and effective cooling of the machine assuming
negligible resistance in the winding and these apply to
cos  =
Re
(32 ) all electrical machine.
Re 2 + Xe 2
6.4 Power Factor Improvement Technique
For the same set of values of XC as used before, a plot In conventional reluctance machine the power factor
of power factor for a range of δ ranging from 0 to 45o is improved through the use of shunt or series
is as shown in Figure 7. Here it is evident that the capacitors. These methods have their relative demerits
power factor appreciates as the value of capacitive which made the technique not survive the test of time
reactance approaches the value need for zero since the use of shunt capacitors does not lead to a
quadrature axis reactance. change in maximum output of the machine and the
series capacitor will lower the overall impedance of

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 892
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
the machine resulting in a higher Xd/Xq ratio. The References
synchronous hybrid machine unlike the conventional 1. A. S. O Ogunjuyigbe, A. A Jimoh, D. V Nicolae
reluctance machine can supply lagging loads as a and E. S. Obe. 2010 “Analysis of synchronous
generator and a leading load as a motor because of its reluctance machine with magnetically coupled
ability to operate in the third and fourth quadrants. three-phase windings and reactive power
compensation”. IET Electric Power Applications
7. Conclusion 2010, Vol.4, Iss. 4, pp. 291–303
A hybrid synchronous reluctance machine with an 2. Anih L U. ‘The Performance characteristic of
ultra-high XD/XQ ratio at good power factors has been coupled round and salient pole synchronous
presented. The new machine is expected to have a machines’ Ph.D Thesis March 1999.
relatively better asynchronous characteristic than a
conventional synchronous reluctance machine 3. Juha Pyrh¨onen, Tapani Jokinen and Val´eria
because the difference between the rotor d-axis and q- Hrabovcov´a Design of Rotating Electrical
axis reactances is not so pronounced as in a Machines 2008 John Wiley & Sons, Ltd pp. 391-
conventional synchronous reluctance machine. The 380.
pull-in torque, as a ratio of the pull-out torque will 4. T. Lipo, "Novel reluctance concepts for variable
therefore be greater. The stability of the machine on speed drives," in Mediterranean Electrotechnical
load can be raised by capacitance tuning after the conference, MELECON, 1991, pp 34-43.
machine has been brought to synchronism.
5. M. J. Kamper and A. F. Volschenk, "Effect
The hybrid machine operating from a common busbar of Rotor dimensions cross magnetisation on Ld
and not requiring dc excitation is expected to be a and Lq Inductances of Reluctance Synchronous
more robust and cheaper machine than the machine with cageless Flux Barrier rotor,"
conventional synchronous generator as slip rings and IEEE Proceeding- Electrical Power Application,
excitation devices and their accessories will be vol. 30, pp. 213-220, 1994
completely eliminated. Absence of rotating windings 6. I. Boldea, X. Fu, and S. Nasar, "Performance
will permit larger rotor diameter D which boosts the evaluation of axially laminated anisotropic
output power of the machine by a factor of D2. (ALA) rotor reluctance synchronous
Furthermore, it will permit the use of higher rotor motors," IEEE Transactions on Industry
speeds since centrifugal forces on the windings will Applications, vol. 30, pp. 977-985, 1994.
be completely absent. If the number of poles of a
given machine is halved from 4-pole to 2-pole, say, 7. F. Parasitili, M. Villani, and A. Tassi,
rotor speed as well as the output power will double for "Dynamic Analysis of synchronous Reluctance
a given size of the rotor, resulting in a higher power motor drives based on Simulink and Finite
density. element model” in IEEE 32nd annual conference
on Industrial Electronics, IECON 2006, pp1516-
Consequently, for a given mass of rotor, the axial 1520.
length of the machine could be shortened and this will 8. A. Vagati, "The synchronous reluctance
eliminate some mechanical problems associated with solution: a new alternative in ac drives," in
long axial lengths like sagging and whirling. 20th International conference on industrial
Additionally, the inertia of the machine will increase electronics, control and instrumentations,
and thus improve stability. IECON'94. vol. 1, 1994, pp. 1-12.
9. E. S Obe and T. Senjyu, "Analysis of a
The added effects of larger rotor diameter and
polyphase synchronous reluctance machine
increased speed can quadruple the output power for a
with two identical windings," Electric Power
given machine size. The hybrid machine has power
System Research vol. 76, pp. 515-524, 2006.
factor control, which could be made leading or
lagging depending on the tuning of the capacitance 10. L. A Aguand L. U Anih, “A variable Xq
loading of the auxiliary winding, a feature that cannot Synchronous Machine” Proc. Electrical Pow.
be accomplished in conventional synchronous Engr. Conf (EPEC). UNN, 1997, P.48
reluctance machines. 11. A. Chiba, T. Fukao, and M. Matsui, "Test Results
on a Super High Speed Amorphous Iron

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 893
International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470
Reluctance Motor," IEEE Transactions on 17. P. J. Lawrenson and L. A. Agu, “A new unexcited
Industry Applications, vol. 25, pp. 119-125, 1989. synchronous machine,” IEE Proceedings, vol.
110, no. 7, p. 1275, 1963.
12. T. Matsuo and T. A. Lipo, "Rotor design
optimization of synchronous reluctance 18. P. J. Lawrenson and L. A. Agu, “Low-inertia
machine," IEEE Transactions on Energy reluctance machines,” IEE Proceedings, vol. 111,
Conversion, vol. 9, pp. 359-365, 1994. no. 12, pp. 2017–2025, 1964.
13. A Vagatti, A. Canova, M. Chiampi, M. 19. P. J. Lawrenson and S. K. Gupta, “Developments
Pastorelli, and M Reprtto “Design Refinement of in the performance and theory of segmental-rotor
synchronous Reluctance Motor through finite reluctance motors,” IEE Proceedings, vol. 114, no.
Element Analysis” IEEE transaction on Industrial 5, pp. 645–653, 1967.
Application , Vo;. 36 pp 1094-1102 2000 20. S. Williamson, E. R. Laithwaite, “Generalized
14. I. Boldea, Reluctance Synchronous Machines and harmonic analysis for the steady-state
Drives. Oxford: Claderon Press, 1996. performance of sinusoidally-excited cage
induction motors” IEE PROCEEDINGS, Vol. 132,
15. Lawrenson P. J and Agu L. A, “theory and
Pt. B, No. 3, pp 157-163, MAY 1985
Performance of Polyphase Reluctance Machine”,
IEE Proc., vol. 111, No 8, August 1964. Pp 1435- 21. W. Fong, “Change-speed reluctance motors,” IEE
1445. Proceedings, vol. 114, no. 6, pp.797–801, 1967.
16. A. J. O Cruickshank, R. W. Menizes, A. F
Anderson, “Axially laminated anisotropic rotors”
Proc. IEE, Vol. 13, No. 12, 1966, P. 2058.

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 6 | Sep-Oct 2018 Page: 894

Das könnte Ihnen auch gefallen