Sie sind auf Seite 1von 2

Task Requirements Summary

The Final Design Report shall document the design stages of the structural design project for this .

A list of the required report components is as follows.

2)Constraints, Opportunities & Assumptions

3)Loads Summary (I have provided that).

4)Structural Analysis & Design (nominated elements

)5) Drawings for Tender Purposes

6)Safety in Design Assessment

Make reference to input documents rather than recreating or repeating reference information.

2. Constraints, Opportunities & Assumptions

Identify ALL relevant constraints and opportunities identified during your project work and
provide a concise explanation of the impacts of these constraints and opportunities to the design
process and proposed solutions. Clearly identify, explain and justify any assumptions that were
made during the analysis and design process

4. Structural Analysis & Design Analysis and design shall be completed for
the structural elements nominated in Table 1 using appropriate hand calculation
procedures learned during class, seminar and studio sessions. Calculations for each element shall
detail the full solution procedure and shall include clear sketches/figures as required to explain and
support the calculation procedure. Address and justify the limitations of your analysis and/or design
where appropriate.

typically, the analysis and design procedure for each element shall include the following steps: -
Calculation of loads-

A diagram / free body diagram (FBD) showing all components, loads and dimensions

-Analysis to determine critical actions for Ultimate Loading

-Capacity Design for Ultimate Actions-Deflection Check for Serviceability Actions-Summary of design
solution, including factor of safety (FOs)

A.Deck Cross Beams A typical cross beam shall be designed for critical ultimate bending and
shear actions and for deflection behaviour under serviceability loading. (Analysis and design
required)
B.Main Girders The main girder members shall be designed for ultimate bending and shear
actions and for deflection behaviour under serviceability loading. (Analysis and design required.)

C.Lift Support Structure All lift support structure members shall be designed for ultimate axial
actions and for deflection behaviour under serviceability loading. Note: Design only – analysis
results from Group work should be used here.

D.Lift Pad Footing Determine the pad footing dimensions required to satisfy performance
requirements for bearing and stability.

5. Drawings for Tender Purposes

Provide drawings which clearly describe the tender stage design solution. Drawings may be
hand drawn or produced with drafting software, but must include sufficient information for
tenderers to prepare a price for the work. This shall include member sizes, number of members,
material grades and dimensions as a minimum for all project elements addressed in the preceding
section. All drawings shall be A3 size with a standard title block which contains: ∗Project Name;
∗Drawing number, title, revision number and date;∗Prepared By & Date; ∗Approved For, By and
Date

6. Safety in Design (SiD) Risk Assessment

Provide a Safety in Design Risk Assessment, which addresses the 4 most significant hazards (as
determined by you, according to the risk assessment) for the proposed infrastructure. This
shall include the following items which must be either identified and / or provided with a
proposed solution.

∗Hazard, Design Life Cycle Stage, Risk (from Group Report)

∗Existing Control Measures

∗Initial Risk Rating

∗Potential Control Measures

∗Responsibility

∗Decision / Status & Required Timing

∗Residual Risk Rating

∗Comments (if appropriate).

Das könnte Ihnen auch gefallen